HomeMy WebLinkAboutProduct Approval Wind LoadGENERAL NOTES 1. Construction shall follow Florida Building Code as adopted by the County or City in which the building is to beconstructed with all - applicable amendments. 2. The Contractor , Subcontractor , Supplier , Etc shall verify all PP ' dimensions , conditions at the jobsite, plans and Specifications. 3. All written dimensions on these drawings takeprecedence over scaled dimensions 4. Structural features not detailed on these plans will be addressed by the engineer as construction progresses. STRUCTURAL NOTES 1. Design Loads: Roof (DL+LQ) 50 PSF Wind Velocity- 163 MPH Supporting Structure (Fastest Mile) 2. Soil Bearing Capacity 2500 PSF with Compaction Test Result of more than 95%. 2a.Soil density shall be in compliance with R401 of 2020 Florida Residential Building Code 3. All Structure Concrete and Grout shall have a minimum compressive Strength of 3000 PSI at 28 days . 4. Slab/Footings to be concrete with minimum ,compressive Strength of 2500 PSI at 28 days . See plans for size and steel requirements. 5. Minimum Concrete protection for reinforcement Bars: Beams: 1 1 /2 Footings: 3" 6. Lap all reinforcing Steel a minimum of 48 bar diameters. 7. All Standard Lumber shall be SPF or stud grade with minimum Fb=1200 PSI or better. 8. All lumber in contact with concrete or masonry shall be Pressure Treated. 9. Splitting or cracking of structural components due to installation of hardware is not permitted. 10. Unless otherwise noted , the installation of specified hardware shall conform to the manufactu r ,instructions..and-standards. 11. Bearings points of headers, gi%ders and beams shall have vertical supports sufficient to support loads and shall be properly 0 WINPOW ANP POOP 5CHFI21� / FFOPUCT Appt?OVA.S OPENING In PPOf7UCt M01�EL NUMP3 rl WINDOW OR f700P MFG't?, PPOnUC-r PF-51GN PPESSUPE IMPACT' r:E5151TAN1 lN5rALl,A11ON'& A'I`TACHMEN-r METHOP ACCEf'AI'NCE NUMBED n F_XPlRA11ON POOk Extcrlor Poor Outslncl TrinFW Glass lnt, + 60, -60 Yes Pcfer to 5peciflcatlons & Prawinq in Product Approval FL#* 20867 12/ 3l/2024 SLIbING GLASS POOP SEPIES 70 5 X 5 0 American Craftsman + 50, -50 Yes Defer to Specifications & Prawinq in Product Approval FLU* 14996 ' 8/,03/ 2021 WINnOW Si le Hu 1 r Jeid-Wen + 65, -70 Yes Defer to 5peciflcatlons & Prawlnq in Product Approval FLU* 14095 4/ 30/ 2025, POOF Underlaumcnt 304 Pelt Owem , Corninq N/A N/A kefer to 5peciflcatiom & f rawinq in Product Approval FL # 11602 " 12/ 31 / 2023 POOF Metal Pont' SV Panel Union Corruclated Co. 120.9 p5F N/ A 12efcr to 5pecifications & Prawlncl in Product Approval FL # 7271-P5 9/ 07/ 2027 anchored for uplift as will be noted. 12. Roof Sheathing to be nailed with 8d Galy. nails or equal, 6" O.C. 13. Unless otherwise noted for exterior walls, exterior plywood sheathing and interior drywalls is to be nailed with 10d nails or better ,_ 6" O.C. edges and 8" 'O.C. Filled . Drywall screwsr 1.5" long and .131" in diameter. 14. For ridge vent. installation block with 2x4 #2 HIP or better between top chords or trusses along the edge of plywood directly below the vent: 15. For Frame Segment to masonry segment connections use PT vertical secured tomasonry with 3/16" dia. ` lag screws 3/4" embedment to 3000# concrete- min 18" O.C. 16. WALLS: The double splices) stiali resist 40001b s ' lice top (butt s ) p / p plates shall be lapped a .es All wall to .min. of 24"@ splices w/ 7-16d nails min. lap center 1/3 of wall shall be 4' w/9-16d nails. l 7 asses for e first two all blocking to the t r th provide f x• A t Gable fide 2x4 g truss spacing, spaced at 4' O.C. nailing shall be ` 4" O.C. at first truss. 18. Apply Plywood roof sheathing face grain perpendicular to supports. 1 19. All roof covering shall be applied per manufacturers recommendations or per FBC and local codes whichever_ is more strenuous. JURISDICTION: ST. LUCIE COUNTY CODE: `' 2020 FLORIDA BUIILDING CODE B'I,U:ILDING CLASSIFICATION: CATEGORY Ii MINIMUM SOIL BEARING PRESSURE: 2500 IDsf - LATERAL LOAD OF TRUSS ANCHORS CONSIDERED: YES SHEAR WALL CONSIDERED: YES CONTINUOUS LOAD PATH PROVIDED: YES WIND SPEED (3 SECOND GUST): 160 MPH IMPORTANCE FACTOR: 1.0 EXPOSURE: CATEGORY C MEAN ROOF HEIGHT 14'-0" BUILDING DESIGNED AS: ENCLOSED INTERNAL- PRESSURE COEFFICIENT + -0.18 EXTERNAL PRESSURE COEFFICIENTS FOLLOWS: VERTICAL GCpf: + -1,07 HORIZONTAL GCpf: -1.4 ROOF OVERHANG GCpi: ± 0.55 BASIC VELOCITY PRESSURE. 29.85 psf FOLLOWING WIND PRESSURES BASED ON Atrib: 50 SF (5 psf DEAD LOAD USED IN CALCULATING UPLIFT) ZONE 1 MWFRS: +32.12 psf ZONE 2 MWFRS: 12.29 psf ZONE 3 MWFRS: 27.61 psf ZONE 4 MWFRS: -25.12 ps f ZONE 4 COMPONENTS & CLADDING 43.5/-45 psf ZONE 5 COMPONENTS & CLADDING: 43.5/-45psf 16'x10' OHGD 39/-42.3psf ROOF UPLIFT MOMENT 14.5 FT-LBF ABRAHAM CHABAB, Inc. Q PL. BOARD OF PROF, ENG. 'AUTH:#26790 SCOPE OF WOPK: - mmovl� 3 POOR5 & PEPLACE W/ NEW f700P5 - PEMOVE 4 WINfJOWS & PEPLAa W/ NEW WINDOWS - PEMOVE EX1511N6 CONCPETE SLAB ANn MPLAGE PEP PI -AN - CON5TPUCT COVEMP POPCH PEP PLAN - PEMOVE EXI51NG 5HINGLE5 & MPLLACE W/ METAL POOF ttII GQQ*1 REVIEWED CODE ;COMP' ST. LUCIE CI �!"A@ �.. FILE COPY ;op oe t. COVERED PORCH ADDITION DESIGNED BY Neal Wilkins AC 117 E. ALDEA ST. DRAWN BY PORT ST LUCIE, FLORIDA AC �s C6 1391 NW ST. LUCIE WEST BLVD #411 PORT ST. LUCIE FL. 34986 Email agchababl®msn.com 772-475-6630 PRODUCT APPROVAL DATE 3 / 10 / 21 WIND LOAD SHEET 1 oF5