HomeMy WebLinkAboutProduct Approval; Metal RoofingEVALUATION REPORT OF UNION CORRUGATING -C.OWANY ,426 GA. 5V-,'PANEL' FLORIDA BUILDING CODE 7TH EDITION (2020) FLORIDA PRODUCT APPROVAL FL 7271.2-R,5 ROOFING METAL ROOFING Prepared, For: Union Corrugating Company 701 & King ' St. Fayetteville,NC 28,301 Telephone: (010) 48&Q479 Fax; (910) 483"109.1 Prepared By: Bala So9kalingam, MIX, P.E. Florida Professional Engineer #62240 1216, N Lansing Ave., Suite C Tulsa, OK 741.06 Telephone: (918) 492-59,92 FAX: (866) 366,4543 This report consists, of Evaluation'Report (3 Pages including cover) Installation Details. (2 Pages) Report No. C2400-2 Date: 10.9.2020 BILE COPY , o 0, K A L 1/v No 62240 M LLI OF 0 B FL 7271.2-R5 C2400-2 10.9.2020 Page 2 of 3 Manufacturer: Union Corrugating Company Product Name: 5V Panel Panel Description: 24" wide coverage with (5) 1/2" high ribs Materials: Minimum 26 ga., 80 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Corrosion resistant as per FBC 2020 Section 1507.4.3. Deck Description: Min. 19/32" thick APA rated plywood or min. W thick wood plank (min SG of 0.42) for new and existing constructions. Designed by others and installed as per FBC 2020. Underlayment: Minimum underlayment as per FBC 2020 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with FBC 2020 Section 1507.4.2 Design Uplift Pressure: (Factor of Safety = 2) Fastener pattern 1 120.9 psf at fastener spacing of 24" o.c. Fastener pattern 2 85.8 psf at fastener spacing of 24" o.c. 113.1 psf at fastener spacing of 12" o.c. Panel Attachment: Fastener pattern 1 #9-15 or #10-14 x 1.5" long wood screw with washer. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. At panel ends max 6" o.c. across panel width through panel flat At interior max 12" o.c. across panel width through panel flat Fastener pattern 2 #9-15 or #10-14 x 2" long wood screw with washer. Fasteners are corrosion resistant as per FBC 2020 Section 1507.4.4. At panel ends max 6" o.c. across panel width through panel flat and rib At interior max 12" o.c. across panel width through panel rib Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2020 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2020 Section 1609 or ASCE 7-16 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High FL 7271.2-R5 C2400-2 10.9.2020 Page 3 of 3 Velocity Hurricane Zone. Fire classification is not within scope of this Evaluation Report. Refer to FBC 2020 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125-03 Test Reports Farabaugh Engineering and Testing Inc. Project No. T164-06, Reporting Date 6/8/06 Hurricane Test Laboratory Report No. 0293-0202-06, Reporting Date 4/5/06 Hurricane Test Laboratory Report No. 0293-0609-05, Reporting Date 8/31/05 PANEL PANEL FASTENER SEE DETAIL 2 SEE DETAIL 1 SPACING PER ALLOWABLE ROOF PANEL �—THIS SHEET THIS SHEET WIND LOAD TABLE n u u n I u �PANELFR n n u DECK ATTACHMENT AND UNDERLAYMENT SHALL BE INSTALLED SUPPORTS MUST BE SPACING PER ALLOWABLE AS PER MANUFACTURER'S INSTALLATION DESIGNED AND INSTALLED WIND LOAD TABLE GUIDELINES BY OTHERS —MIN. LA_ YYUVU RAPILtt/JUIJI/ TRUSS AT MAX. 24" O.C. UNDERLAYMENT #9-15 OR #10-14 X 1.5" LONG W WITH WASHEF UNDERLAYMENI TYPICAL PANEL INSTALLATION X-SECTION #9-15 OR #10-14 X 1.5" LONG FASTENER PATTERN 1 WOOD SCREW WITH WASHER DETAIL 1 ULIAIL L 26 GA. PANEL PLYWOOD 19/32" THICK (MIN.) 26 GA. PANEL YWOOD /32" THICK (MIN.) FASTENER PRESSURE SPACING (PSF) (IN) 24 120.9 GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE (FBC). 2. ROOF PANELS ARE SHALL BE MINIMUM 26 GA. EFFECTIVE COVERING WIDTH OF PANEL = 24". 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS ARE GREATER THAN THE ALLOWABLE WIND LOAD TABLE. 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL. 6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS. O o U M U wNLo Z 01 Q NUN 6 UZ I ZWM e 00 0 Ya U uii-,o g o° OF PANEL PANEL FASTENER ROOF PANEL _ / SEE DETAIL 4 SEE DETAIL 3 SPACING PER ALLOWABLE V — SHEET 2 SHEET 2 WIND LOAD TABLE u VUNDERLAYMENT \ � \INSTA o DECK ATTACHMENT AND SHALL BE LLD SUPPORTS MUST BE AS PER MANUFACTURER'S INSTALLATION x DESIGNED AND INSTT ALLED GUIDELINES BY OTHERS I Inlnral eve —MIIN. LA_ Y—u—ricR/JVIJI/ TRUSS AT MAX. 24" O.C. DETAIL 3 #9_lc no u,n ,� v a Inur WOOD I lKIM01 AV11 DETAIL 4 TYPICAL PANEL INSTALLATION X-SECTION FASTENER PATTERN 2 26 GA. PANEL YWOOD 19/32" THICK (MIN.) J 26 GA. PANEL LYWOOD 19/32" THICK (MIN.) ALLOWABLE UPLIFT PRESSURE FASTENER PRESSURE SPACING (PSF) (IN) 24 85.8 12 113.1 2 OF 2