Loading...
HomeMy WebLinkAboutBuilding PlansALL WORK TO BE PERFORMED IN ACCORDANCE WITH THE FBC 2017 SIXTH EDITION, THE NEC, FLORIDA FIRE PREVENTION CODE LATEST EDITION WITH LATEST SUPPLEMENTS EXISTING DOOR TO BE REMOVED AND RATED WALL SECTION TO BE REPLACED - °�, , y SEE WALL IN -FILL SECTION THIS SHEET TENANT SPACE UNI #12 (8645 _SUS HWY 1) TENANT SPACE UNIT #13 (8643 S US HWY 1) FUTURE TENANT BUILD -OUT BY OTHERS EXISTING 1-HOUR RATED FIRE -WALL TO BE REPAIRED @ LOCATIONS INDICATED - SEE DESIGN NO. U465 SHEET S2.01 11 (V EXISTING SECTION OF + (' TED WALL TO BE REPLACED - SEE IN -FILL EXISTING PARTITION I` WALLS IN + SPACE TO REMAIN EXISTING PARTITION WALLS IN SPACE TO REMAIN INDICATES WALL OR DOOR AREA TO BE —j IN-FILLED/REPAIRED RATED WALL REPAIR PLAN SCALE: F ( t t EXISTING WALL OPENING LIGHT r') EXISTING LIGHT GAUGE WALL TO REMAIN GAUGE HEADER ` ABOVE & TO SIDES OF OPENING LOCATIONS REMOVE EXISTING GYP. BOARD TO MEET JOINT STAGGERING REQUIREMENTS OF 1-HOUR RATED ASSEMBLY U465 SECTION (4) 6" 20 GA. GALV. METAL TRACK -ATTACH TO 3.5" FIBERGLASS EXISTING HEADER W/ BATT INSULATION (2) #12 TEK SCREWS @ FROM ENDS 2< (1) LAYER 5/8" TYPE X GYP BOARD ON EACH SIDE - STAGGER JOINTS ON OPPOSITE SIDES OF WALL - SEE r 1-HOUR RATED ASSEMBLY U465 + SHEET S2.01 SECTION (4) FOR GYP. BOARD ATTACHMENT INSTRUCTIONS ?. .2 6" 20 GA. GALV. 6" 20 GA. GALV. METAL METAL STUDS @ 16" = TRACK - ATTACH TO O.C. MAX SLAB W/ a"0 4' x TAPCONS @,) 16" O.C. & `t! 6" FROM ENDS EXISTING NOTE: NO THRU WALL PENETRATIONS OR ADDITIONAL CONCRETE SLAB PENETRATIONS AT WALL IN -FALL LOCATIONS OR EXISTING WALL - IF ELECTRICAL BOXES ARE ADDED THEY MUST MEET THE FOLLOWING - STEEL RATED WALL IN SECTION ELECTRICAL BOXES 16 SQ. I. MAX & AGGREGATE —FILL AREA OF OPENINGS INWALN DOES NOT EXCEED 100 SCALE:314"= r-O" SQ. IN. (SPACE BETWEEN BOX AND WALL MEMBRANE NOT TO EXCEED 1/8 INCH & BOXES TO BE SPACED HORIZONTALLY ON OPPOSITE SIDES OF WALL BY MIN. 24 INCHES) - SEE 2017 FBC SECTION 714.3.2 Sf. 0clejCo. F' Daf PP)to gE,VjSWEn BY: DATE: REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC �,J rc.e, .> FILE COrY °� 8 =~�oLo c NSuv,m � N C6 CD d O V Q 0 a X. y Ito v � y ti sz-^nmmwm¢n�n�t� CHRISTOPHER J. HAMMEL c FL PE #81811 e� tttt„w °,,nptrry� 1 �� OPHER *, a$ A rf1'a s� m s� J m E 'u^i vJ W a € 3 � M s r g r zLUr u W Q w e � 8 N J a N v m N � N N IL w in N r~tz c aa w U) y w w S D ui w J �o a a zw y z (y o " w� Z a o c�i a xi co u w (L '>4 ® ow ¢ c w € w ? a a s c> r r aLd w m w w - U z a vri chi IL ,c �u r� n ri C oiz W c 'c J �$ W =e s- Uco Z p U) W (L w „ as plllllllllll�� ui I I I I I I I I ZN MI fJ ,f0 r CD CD a!'! PROJECT#: 191031.CP12.dwg = b DATE: February 26, 2019 SCALE: AS SHOWN ¢ DESIGNED BY: — e g cx DRAWN BY: — CHECKED BY: — x SHEET TITLE a PLAN & DETAILS r� c S1.01 I SHEET 1 of 2 s )esign No. U465 Meet, astaorkid to floor and wiling with fasrecer, spaced STUDCOBUILDWG$YSTEMS-CROCSTUD I board and 12 in, OC in the field of the board, Joints USG BORAL DRYWALL SFZ LILC - Types C, GCX, 4L Gypsum Bowe - (Not Shown) - (As an alternate compound overall Irma As an alternate, nominal 3/32 Secured 90 Stud$ Win No, U X Z-V2 in, coarse drywafi screw through fte center increased by minimum 314 In&. Not evaluated or 14 in. OC max, oriented vertically and staggered on opposite sides of the USGX (Joint tape arid compound, farm 6, optional for use to Item 4 wren used as the base joyer on one or both in, thick gypsum veneer Plaster may be applied to the hole. Resilient channels are secured to intended as a substitute for the required layers) of UL February 19, 2019 TELLING INDUSTRIES L L C - Vitter201in Track I assembly. When attached to Items 6 (resilient channels) ,Min Type USGX) sides of wall. For direct attachment only to Steel studs entire Surface of Classified veneer baseboard. Joints clips with one No, 10 x 1,12 in. part-linsaid Classified Gypsum Board. 2H Framing Members* - Steel Studs - Not St own or SA, 611, SC, 60, or BE (furring channels), Water board is vim attached to furring channels with I In. Item 2C). Noun 518 in, thick lead backed gypsum panels with beveled, square or lopered edges, applied vertically. reinforced Paper tape and joint compound may ba omitted when gypsum boards are supplied with square self-drildrig screw. MSIL - RefieXor membrane, SONOpan panel - In lieu of Item 2 - For use with Item I 1, propreal ary long, Type 6 steel screws spend 12 in. OC. USG MEXICO 9 A DE C V - Type AR, C, IP�AR, [P-XI, verfical Joints centered over studs and staggered Min I r edges, KEENE BUILDING PRODUCTS CO A J, Framing fifiembems* - Fluor and Coiling Runners channel shaped steel studs, 1-114 in.wide by hun:t-518 ACADIA DRYWALL SUPPLIES LTD - Type X 5lul I P42, IPC-AR. SCX, SHX, USGX, WRC or WRX (Joint stud cavity on opposite sides of studs. We Ilboard secured ING -Type RC+ Assurance Clip filonlibearing Wall Rating - 1 HR. - Not Shown -:In lieu of Items 1 - For use with Item 2 in. deep fabricated from min 0,020 im thick gaiv sfirffi� StudscutSAin less in length Than assennally height, Type X Type Blualegiass Exterior Sheathing � tape and compound, Item 6t optional for use with Type to studs with 1-1/4 in. long Type S-12 steel screws 6, Resilient Channel - (Optional - Not Shown) - 25 * Indicates such products %hall bear the UL or oUL Certification L proprietary channel shaped runners, 1-V4 in, deep by TELLING INDUSTRIES L L C - vnr20- USGX) gypsum panel steel Screws spaced 8 In, OC at perimeter MSG gaiv steel resilient channels spaced vertically max Mark for jurisdictions employing the UL or cUIL Certification - findicables such products shall bear the UL or cUL Cerinfication Mark min 3�518 in. wide fabricated from min O�018 in, thkck9Wv - i and i2 in, OC In the field, Lead batten s"n required 24 in. OC, flange porflon attached to each intersecting 7� Wall and Partition Facings and AccessorteV - (such as Canada), restrictive4y. figrJurisdictions employing the UIL or cUL Certification (such as Meet, attached to floor and calling with fasteners spared AMERICAN GYPSUM CO - Types AG-C1 AGX-1, M- behind vertical joints of lead backed ifirpsum wallboard stud with 112 in. long type S-12 pan head steel screws, (Optional, Not Shown) - Nominal 112 in, thick, 4 " wide Canada), respectively. 24 In. 00 max, STEEL INVESTMENT GROUP L L C - AlphaTRAK Glass. LightFroo 4B, Gypsurn Board' - (As an adamant to Items 4 Or and optional 0 remaining stud locations, Lead batten strips, min 2 in. wide, max 8 If longwith a max flihickness, May not be used with hem 4F, 4J or 4L. panels, for optional use as an additional layer on one or Last Updated on 2019-02-19 2t, Framing sharincerV - Steel Studs - In lieu of Item 4A) - Norn &4 tn. thick, 4 At wide, installed as described of OA4 n placed on the face of studs and attached to the 6A. Steel Framing MembieW - (Not Shown) - As an both sides of the assembly Panels atiadred In ' `,Wils`�V� v`k1.a,,`i 2 - For use with Item 1, channel shaped studs, fabricated finart min 25 MSG ocearcifion-prolected steel, 3- � BEIJING NEW BUILDING MATERIALS PUBLIC LTD 00 - Type OSX- I in Item 4A with screw length bicireabled! to 1-1/4 in. CGC INC - Types AR, IP-AR stud with construction adhesive and two I in, long Type S- 12 pan head steel screws, one at the lop of the Strip alternate to Item 6, furring channels and Steel Framing Members as desofibed below accordance with manufacturers recommendrations. When " the QR-600 orOR-510 panel is trietatled between the I I ­ I - "I'll, ...... _ ...... __­ -1 .1111, ... 1111---, �, - DissigmiSysten onstructionlAsseennibly Usage W k�v W A IK Framing Membehai - Floor and Ceiling Ronnens 5fa in, dead, (min), spaced 24rn. UQ max. �wvli A betut and one at the bottom of the strip, Lead discs. nominal steel framing and the UL Classified gypsum board, the Disclaimer 11 " " - Not Shown - In lieu of Item 1 - For use with Item 314 in. Was than assembly height- 318 in. diaM by Max 0.085 in, thick, Compression fitted or a. Furring Channels - Formed of No. required UL Classified gypsum board layarts) slare to be �, I/ "I I I ""; /,11 1 2M. proprietary channel shaped runners, I-Im in, win 3 ED METAL INC - NITROSTUD CGC INC - Types AR, 0, P-AR, IP-XI, IP-X2,, IP0-AR, UNITED STATES GYPSUM CO - Types AR, IP-AR adhered over the screw heads. Lead batten Strips and 25 MSG gaiv steel, 2-9116 in, or 2-23i32 installed as indicated as to fastener type and spacing, � � 1� 1 ; D I , � by min 3-5M in, deep, fabricated from min 26 MSG � �1 - I - I - -, 1-1 .. " - SCX, SHX. USGX, WRC or WRX (Joint tape and discs to have a purity of 99.9% meeting the Federal im wide by 778 in- deep, spaced 24 in, except that the required fastener length shall be - Authorities Having Jurisdiction should he consulted In all cases as to I �� � I �� � i, " -J I , nolsi I bare metal thicknes-1, attached to floor I . OC periternsficular to studs. Channels increased by a minimum of V2 in. Not evaluated or the particular requirements covering the installation and use of UAL � , 'C � JI 11 �, V4 i "I I , - I "I'll-, �,x ­ , 1, � i � " , I'li-KAYA. '_ 11.1'.. - - 11 ,,, I 1�­ 11 - ­ , f 1�1 ­ _� � 1_� I 1� � . "I'll ... 11111�1 � , �_� '. lr n ran. I and ceflaigi with fasteners spaced 24 in, OG raax� CALIFORNIA EXPANDED METAL PRODUCTS CO - 2,11 Framing Members'l -Steel Studs- In lieu 44 Ittimi compound, item 5, optional for use with Type USGX) 1.13G MEXICO S A BE C V - Types AR, IP-AR specitication QQ -L-201 f. Grade � RADIATION PROTECTION PRODUCTS INC - Type RPP Lead Lined Drywall Secured to studs as; described in fair b. Ends of adjoiningt Channels ans intended as a substitute for the required layeris) of UL Olasefied Gypsum Board. Certified products, equipment System, devices, and matenals, - Authorities Having Jurisdiction should be consulted before .... , � , � , � , � , = ­ 11 -.1 I., , � , � , I , 1 P`ie �' . 1, Viper X Track 2 - For use with Item 1, channel shaped studs, fabricated from min 25 MSG comosbri-pretachad a : eel 3-1 ' CERTAINTEED GYPSUM INC - Types 1, EGRG, - overlapped 6 in, and -,led together with double $trend of NO, A a SWG itsiv steel PASCO BUILDING PRODUCTS L L C, DBA PASCO GYPSUM - Type QuietRock OR-500 and QR.510 construction. - Fire resistance 05semblises and products Sea developed by the I %, il 4) 518 in. deep (min), spaced 24 in. OC max. Studs 1K X4 in, less than assembly height, be cut OtasRor, Type X, Type X-1, Type C, Type X-2� V61" Eaa� Lite Type X� FssiAita Type X-2 4C, Gypsum Board' - As an alternate to Items 4t 4A, virre near each and of ovedap. As an design subminer and have been investigated by UL for compliance with applicable The finformation " Zi : and 48 --- Nord, SIS In, Thick gypsum panels, with square 4M. Gypsum Board* - (For use with Item 8) - 5in in, areanane, ends of adjoining channels requirements, published cannot IL. Framing Members'- Floorand Coiling Runners OLMAR SUPPLY INC - PRIMESTUD ! ; edges: applied horizontally, Gypsum panels fastened to thick: 4 ft wide, apipfied vfid�cafly over Mineral and Fiber Alney be Overlapped 6 in, and secured Ofieseys address every conetruction nuance, encountered in the field� 1. Floor and Coiling Runners - (Not Shown) - - Not Shown - tn lieu of Item I - For use with Item � CONTINENTAL BUILDING PRODUCTS OPERATING framing with I in. long bugle head sled screws spaced a Board (itam 8) with vertical joints located anywhere over togle9w with two self -Tapping No. 6 8, Mineral and Fiber Board* - (Optional, Not Shown) - When field issues arise� ft is recommended the first contact for Channel shaped runners, 3-5,18 in. deep (min), 1-114 in. 2N, proprietary channel shaped runners, 1.14 in. wide by i I CO, L L C - Types LGFC2A, LGFC5A, LGFC.C/A, max a in, 00, with last 2 screws W4 in and 4 in, from stud cavdies� Secured to mineral arid fiber boards wilh l- framing screws, min WAS in, long at the - For optional use as an additional layer on one side of assistance be the technical Service, staff provided by the product togs, lammed from min No, 25 MSG gaily steel, attached to min 3.519 in, deep ftbricated from min 0.020 im thick gory 2K, Framing Members* -Steel Studs -As an 1 : LGFC-VVD, LGLLX each edge of board, Horizontal joints reed not be backed V2 in, Type G Straws spaced 8 in, OC along edges of midpoint of the overlap, With one screw WmA Nom V2 in. thick, 4 ft wide with long dimension manufacturer noted for the design. Users of fire resistance floor arid Coiling with fasteners spaced 24 in. OC msix� steel, attached to floorand ceiling with fasteners spaced alternate to Item 2 - For use with Item 18 (3-V$ in, wide by steel firs", Horzonliat edge joints and horizontal each vertical joint and 12 in, OC in intermediate field of on each flange of the channel. Not for parallel and centered over studs. Attached to studs and assemblies are advised to consuft Abe general Guide Information for 24 In, 00 max track). channel shaped fabricated from min 25 butt joints on opposite sides of studs on intenor wails the Mineral and Fiber Board (Item 5), Secured to use with Items 4F 4J. or 4L. floor and ceiling runners with 1-518 in. long Type S steel tech product category and each group of assemblies, The Guide IA� Framing Membersai - Floor and Ceiling Runners CRACO MFG INC - SmartTrack2D 1. .Studs, MSG corrosion -protected steel, 1-114 in. wide by 3 518 in, GEORGIA-PACIFtC GYPSUM L L C - Types 5, 6, 9, C, need root be staggered at backed by steel framing, GEORGIA-PACIFIC GYPSUM L L C - Type DGG, outermost studs and floor and ceiling runners with 2 in, b� Framing Members* - Used to screws, spaced 12 in, CC and 24 in, OC along all ruermaidiater framing, The requires UAL Classified gypsum Information includes specifics, consenting alternate materials ard aftemake methods of construction, - (Not Shown) - As an alternate to Item 1 - Channel shaped, min 3Z/8 in. deep, attached to floor and ceiling Z Steel Studs - Channel shaped, 3-5/8 in. deep (mmL deep, Spaced a max of 24 in. OC� Studs to be cut 314 in. less than assembly height, 316 W PFW, LS, Type X� Veneer Plaster Base - Type X, Water Rated - Type X, GriveriGlass Type X long Type S screws spaced 8 in. OC, Gypsum Board joints Covered with paper tape and joint compound, attach furnng channels (Item a) to studs board layer (item 4M) is to be installed over the Minerai - Only products which bear UUs Mark are contildered Certified, with fastentess 24 in, OC. max. formed Inen min No. 25 MSG qWv steel spaced 24 im OC max� Studs to be out 314 in, less than assembly Sheathing - Type X Soffit- Type X, TG-C, GreenGlass Screw heads covered with joint compound, AMERICAN GYPSUM CO -Type AG,C litem 2)� Clips spaced 48 in. OC., and secured to studs with 1-518 in. water or and Fiber Boards, Sets and Blankets, Item 30, and Adhesiv% Item 11, are recturred, 41EPRINTED FROM THE ONLINE CERTIFICATIONS DIRECTORY ALLSTEEL & GYPSUM PRODUCTS INC - Type height Tyne X, Type X ComfortGuard Sound Deadenina 4D, Gypsum Boami As an alternate to items 4, 4A, ' - ' - "' ­ WITH PERMISSION FROM UL SUPREME D24f3CEQ0 and Type SUPREME D20 MARINONVARE, DIV OF WARE INDUSTRIES INC StudRftew - Gypsum Board, Type LWX, Veneer Plaster Base -Type LV&, vilitater Rateo-Type LVvx, Sheathing Type-LWX, 48, and 40 - Nom. 5hi in, thick gypsum panels applied yerfically or Wininatinfly Vertical joints centered over GERTAINTEED GYPSUM INC - Type Flil Type C� he% head Type S steel screw through the center grommet. Furring channels HOMASOTE CO - Homasirta Type 440-32 -0 2019 UL LLC 2A Framing ManitieW - Steel Studs - As an alternate fid Item 2 - Channel shaped Made, gin 3-518 Soffit -Type LWX, Type DGLW, Water Raled-Tipe DGL)/V, studs and staggered one stud cavity on opposite sides of Type X-2 am friction fitted into idips. RSIC�l rilip CONSOLIDATED FABRICATORS CORP, BUILDING Or deep, spaced a max of 24 in, OC, Studs to be out 314 Sheathing Typs� DGLWI Soffit -Type DGILW, Type LW2X, Studs. Horizontal edge joints and horizontal butt joints on opposite sidets, of studs need not be staggered or barked for use with 2-9,'16 In. Woe furring PRODUCTS DIV - Type SUPREME D24,130EGO and im less than assembly hisight 2L. Framing Members* - Steel Studs -As an Veneer Plaster Base - Type LVyi Water Rated - Type LW2X, Sheathing Type �W2X� Soffit - Type LVV2X, Type by steel framing, Gypsum panels fastened to framing with CGC INC - Typest C, IP-X-2, IPC-AR chanmfls� RSI�l (2,75) dip for use with 2-2W2 in. wide furring channels, M, Mineral and Fiber Board - (Optional, Not Shown) - For optional use as sin additional layer on one side of Type SUPREME D20 ALLSTEEL & GYPSUM PRODUCTS INC - ryda SUPREME D2930EQD and Type SUPREME 020 alternate to Items 2 -- For use With Item 1J. charu shaped studs, min 3-5/8 in. wide fabricated from An ef in DGL2W, Misr Rated - Type OGL2W, Sheathing - Type 1 in, long Type 8 steel screws 12 in. OC along vertical PAC INITERNATIONAL L L C - Types wall - Nom V2 in, thick. 4 ft Mile, square edge fiber 0.018 in. thk* gadv steel, spaced a max of 24 in. C C. DGL2yy edges and in the field Screws spaced a max 12 in. Wong the top and bottom edges of the wall Mr both vertical and CONTINENTAL BUILDING PRODUCTS OPERATING RVC-1, RSIC-I (2,75) boards applied vertically to studs on one side of the well 01UAIL RUN BUIILDING MATERIALS INC - Type C ONSOLUDATED FABRICATORS CORP. BUILDING Studs to be cut 3irl in. less than assembly height, STEEL INVESTMENT GROUP L L C - AlphaST JD horizontal applkxsfiors� When used in Moths other than CO, L L C - Type LGFC-CIA, in between the wood studs and Abe UL Classified Gypsum Board (item 4), Fiber boards installed with 1 �114 SUPREME D24/30ECID and Type SUPREME 020 PRODUCTS DIV - Type SUPREME D24/SOEQD and NATIONAL GYPSUM CO - Types eXP-C, FSK, FSK-C, 48 im, gypsum panels to be installed horizontally. im long, Type S steel Screws spaced 12 in, OC max with Type SUPREME D20 i F,SK-G, FSMR-C, FSW-C. FSW-G, FSW, FSW-3, FSWi NATIONAL GYPSUM CO - Types eXP-0, FSK FSK-C, GEORGIA-PACIFIC GYPSUM L L C - TVs% IL DAPC, BE, Framing Mernbers' - (Not Shown) - (Optional on the last screws spaced 2 in, and 6 in, from edge of board, FSIN-6, FSW-8, FSL FSK-G, FSL, FSW-C, FSW-G, FSW, FSW.3, FSVV.5, one or both sides) - As an alternate to Item 6, furring Gypsum board (Rent 4)invallsed as Indicated as to SGAFC0 STEEL STUD MANUFACTURING CO - Type 2W Framing MemborlI - Steel Studs - Not SLYI FSvil FSMR-C TG-C channel and Steel Framing Members as described below, fastener type and spacing. except that the required SUPREME D24130EQD and Type SUPREME 020 QUAIL RUN BUILDING MATERIALS INC - Type - In Item of Item 2 - For use with hishr 1K propran" NATIONAL GYPSUM CO - Riyadh, Saudi Arabia - fastener length shall be increased by a minimum of 1/2 ih� Not evaluated or intanded for The SUPREME V24rNEGO and Type SUPREME 020 channel shaped steel studs. min I-V4 im wide by min 3- Type FAR, or VAR NATIONAL GYPSUM CO - Types eXP-C. FSK-C, a, Furring Channels - Formed of No- as a Substitute required layerfs) of UL Classified Gypsum Board. Net 518 in. deep, fabricated from ran 25 MSG (0,018 rk min. 4E. Gypsum Board* - (As an alternate to Items 4 FSW-C 25 MSG gaiv Meet. 2.3A3 in, wind by 7/8 evaluated for use with Item 4M. STEEL CONSTRUCTION SYSTEMS INC - Type SCAFCO STEEL STUD MANUFACTURING CO - Type bare mintal thoinnessi. Studs out 314 st. less in ishatfida than assembly height through 4D) - Installed as described h Item 4, 5TS in, Thick, 4 ft. wide, applied vertically only and fastened to im deep, spaced max, 24 An. OC perpendicular to studs. Channels BLUE RIDGE FIBERSOARAD INC - Soundigasp SUPREME D24,30EQD and Type SUPREME D20 SUPREME D2030EQD and Type SUPREME 020 CALIFORNIA EXPANDED METAL PRODUCTS CO - I FAISCO BUILDING PRODUCTS L L C, DBA PASCO GYPSUM - Types PQ�C. K-13, PG. 11, PC S-WRS the studs and plates with I in, long, Type S steel screws PASCO SUC04NG PRODUCTS L L 0, DRA PASCO secured to studs as described in Rem As, Viper X spaced, 12 in, OC. GYPSUM -Type PG-C Gypsurn board afiachind to furring UNITED METAL PRODUCTS INC - Type SUPREME STEEL CONSTRUCTION SYSTEMS INC - Type PANEL REY S A - Types GREX, PRC, PRC2, PRX, NATIONAL GYPSUM CO - SoundBroak XP Type X Gypsum Board channels as descifited In Item 4, Not for use with Items 4F. 4J, or 4L 88. Mineral and Fiber BoaW - (Optional, Not Shown) I For oistr6F�Ias an additional layer on one side of 11 ____;� D24j30EQD and Type SUPREME D20 SUPREME D24i3DEQD and Type SUPREME 020 214� Framing Members* - Steel Studs - Nor Shown RHX, MDX, ETX PANEL REY S A -Types PRC, PRC2 b Steel Franninn MembeW - Used to N 2 in ON A ft wids with long dimension - r2Om I 7" Strand - In lieu of Item 2 - For use with Item IL, proprietary . attach furring channels (item 689) to parallel and centered over studs, Attached to studs and deal, and ceding ruterors with 1-5/8 in. long Type S steel UNITED METAL PRODUCTS INC - Type SUPREME channel shaped Steel studa.1-114 in. wide by hen 3-6113 SAINT�GOSAIN GYPROC MIDDLE EAST FZE - Type 4F. Gypsum Board* - (Nor Shown) - (As an alternate SAINT-GOBAIN GYPRADC MIDDLE EAST FZE - Type Studs (Item 2), Clips spaced max. 46 in SanOws, Spend 12 in\QC and 24 in, OC along all 1B, Framing Maimbers"- Floor and Calling Runners 024GOEOD and Type SUPREME D20 in, deep fabricated from min 0.020 in� thick gaiv steel, Studs cut 314 In. less in length than ease imply he Gypmc FireStop, Gyproc FireStop MR, Gypmr FireStop to item 4 when used as the base layer an one of both Gyproc FmvSpp, Gyproc FireStop MR, Gyproci FireStop 00. GENIECLIPS secured to studs Min � intermediate framing. 11is required UL Classified gypsum - Not Shown - In lieu of Item 1 - For use wilth Item CRACO MFG INC - SmartStudI20 . M2TECH, Qyproc FireStop ACTIVAir, Gyproc FcArStop sides of wall, For direct attachment only to steel sWds Item 2C) - Nom 518 in. thick lead backed gypsum panels 142TECH, Gypioc Fire6top AQ-TIVAir, Gyp= Fire -Stop MR ACTIVAir, Gypmc FireStop M2TECH AcTAPAir, No� 8 x 1-112 in. minimum self -drilling, S-12 steel screw through ft writer board layer is to be Metalled over the Mineral and Fiber 28� proprietary channel shaped runners, 1-114 in, wide by 2B, Framing Members, - Steel Studs - Not Shown MR ACTIVAir, Gyprop FiroStop MZTFOH ACTIVAk, Gyproc DucaLlne, Gypmc DuraLins. MR, Gyproo with beveled, square or laMed edqss� applied verticalki, Gyprac DursUms; Gyproc DuraLde MR, GypMO grommet, Furring channels are frictort Boards and secured to studs with length of fasteners increased by 1/2 In, over the length "affleid far min 3-5,'B in. deep fabricated from min 0,020 in, thick gaiv - In tau of item 2 - For use with Item 18, piciphatiari, DuraLine M2TECH Gyproo DAineLine ACTIVAic Gyproc Vertical joints centered overaluds and staggered min I I Ound-ine WTECH, Gyprac: Ourail-ine, ACTIVAir, Gypniq fined into Clips, PLITEQ INC - Type Genie Clip installation of the gypsum boards. Batts and Blankets, steel, attached to floor and ceiling with fasteners spared channel sheiped!t*el Studs, 1-114 in, wide by min 3-5uti 3, Batts and ftnketsk -(Opfional) - �� or DuraLine MR ACTIVAir, GYPMO DuraLine M2TECH stud Cavity on opposite sides of studs, Gypsum board Durl MR ACTIVAir, Gyproc Dural -fine M2TECH Item 3, are optional unless otherwise required. Not for 24 in� OC m", glass fiber baits partially or completely fi JIM , d:�I ty ACTIV" d to studs with A secure -1i4 in, long Type S-12 steel ACTIVAir use with Items 417, 4J, 4L, ard,41A, CALIFORNIA EXPANDED METAL PRODUCTS CO - in. deep fabdicatOdfircol anin 0 020 In, thick 9MV Ideal screws spaced 8 in� OC at perimeter and 12 in, OC In the HOMASOTE CO - Harrassnote Type 440-32 �ApAAOO`u Track Studs cut W4 in. less in length than assembly height. field CALIFORNIA EXPANDED METAL PRODUCTS CO - '_ _­ ' " ' ' " - RAY -BAR ENGINEERING CORP - Type RS-LBG THAI GYPSUM PRODUCTS PCIL - Type C MnA20� See Better and Elarikets (BZJ7-) SIAM GYPSUM INDUSTRY (SARABURI) CO LTD - I- I ­ ­....­ 6Q, Steel Framing Membi - (Optional, Not Shown) 9, Lead Batten Strip$ -- (Not Shown. For Use With fam MARINOAVARE, DIV OF WARE INDUSTRIES INC - category for names of Classified Type EX-1 UNITED STATES GYPSUM CO - Types C. IF-X2. IPC- - Furring channels arid Sisel Framing Members as 4E) - Lead batten strips, min 1-112 in, mWe, max I 0 ft Viper20re Track companies AR described below long with a max thickness of 0.125 in, Ships placed on CRACO MFG INC - SmartStud20"M 3A, Fiber, Sprayned* -As at) alternate to Batts an 4G Gypsum Board' - (As an alternate to Items 4 through 4F) - For use With ItemaID and 2D only, 518 in, Furrim Channels Formed No� the interior facis of OAS and attached hom the exegrior LSPrer THAI GYPSUM PRODUCTS PCL -Type X, Type C a. g - of face of the shid wil I! S-12 pan head - - FUSION BUILDING PRODUCTS - VtpW20- Track Blankets (Item 3) - (100% Bonds Formulation) - Spray Ihi 4 ft wide, attached to sled studs arid floor and USG BORAL DRYWALL SFZ LLC - Type C 25 MSG gals steel, Spaced 24 In OC steel screws, one at the top of the stin I p arid one at the MARINCAIWARE, DIV OF WARE INDUSTRIES NYC - applied cellulose maderial, The fiber a applied with offlOng track wim I in. long, Type S steel screws spaced 8 perpendicular to studs, Channels bottom of the smp. Lead barisu Strips to have a purity Of Viper207m to Completely fill the enclosed carifty, In awordancei with UNITED STATES GYPSUM CO - Type AR, C, FRX-G, in. OC, along edges of boarcLoad 12 in, OC in the field of - the board. Joints secured to studs as described in Item b, 99,9% meeting the Federal specification QQ_1�201A, IMPERIAL MANUFACTLIRING GIROUP INC - -- the application instructions supplied with the product wim - I IP-AR, IP-XI, IP-X2. IPC-AR, SOX, SHY, MC. WRX, oriented vedicZWaing staggered on opposite sides of the asserribly.- __ - USG MEXICO S A DE C V- Types C, IP-X2, IPC-AR Ends of adjoining channels Overlapped 6 tied together double Grade "C". Lead batten strips required behind vertical lyrnar20`u" Track I W-1 B-11 "ING PRODUCTS V - a nominal dry density of 2.7 IWO- . Alternate Application � � USGX (Joint tape arid compound, Item 5, optional for use _M CONTINENTAL BUILDING PRODUCTSIOPER�Agiey� 1, - _­­­ �� I I li�IAAN0 � "I , � -1- in. and with I ­r � I* .1�_ _l,�, A �,g joints of lead backed gypsum board (Item 41E) and - I I I I � ­r,,�r,­,A­_,, pe �� Method: The fiber is applied without water or adhesive at a nominal dry density 03.5 IMP, in accardancewith the with Type USGX) CO, L L C - Type LGF06A, LGFC�CA I 11 -, 1� 1.1t,�""MMMFF-RMNI�"mm""R-RIM"Fwmmmw,w � � 9 go wina G ,ypsum board attached to furring optional at remaining shictionflons. Required behind vartical joints, application instructions Supplied with the product. � 4N, Wall kW'Paftftion Facings and AccestiorhatO - channels as described in Rem 4, Not for IMPERIAL MANUFACTURING GROUP INC - U S GREENFIBER L L C - INS735 & INS745 for we USG BORAL DRYWALL SFZ LLC - Types C, SOX, (As an alternate to Item 4) - Nominal 5,'8 in. Mick, 4 9 use with Items 4F, 4J� or 4L SA Lead Batten Strips -(Not Shown, far usawith ftirri 1C, Floor and Coiling Runners -(Not Shown) -For viper2o I- with wet or dry application. INS765LO and INS77 OLD are USGX (Joint tape and compound, Item 5. optional for use NATIONAL GYPSUM CO - types FSW wind panels, applied vertically and secured as described 4J) - Lead batten strips, 2 in, wide, max 40 ft long with a use with Item 2C - Channel shaped, fabricated from min to be used fur dry application only � Win Type VSGX) In item 4� b. Steel Framing MembeW - Used to mialt thickness of 0.140 in.Zelps placed on ft face of 20 MSG comossion-protacted or galv steel, min depth to PASCO BUILDING PRODUCTS L L C, DBA PABCO attach furring channels (Iterr, 6Ca) to crude, and attached to The stud with two min. A in. long accommodate stud size, vvith min I in, long legs, � UNITED STATES GYPSUM CO - Type,5CX GYPSUM -Tyn QuialtRock 627 studs. Clips spaced 48 in, OC_ and min. Type S-8 pan head steel screws, one at %a Top of attached to floor and ceiling with fasteners spaced max 2C, Steel Studs - (As an alternate to Item 2, For Ace I USA3 MEXICO S A DE C V - Type AR, 0, P-AR, IP-X 1, secured to studs win 2:n, coarse the strip and one at the bottom of the Strip or with one 24 in, OC. with Item 4r) - Channel shaped, fabricated from min 20 38 Fiber, Sprayed* - As an afterrate to Batts and IP­X2, IPC-AR, SCX, SHX, USGX, ARC orWRX (Joint drywadl screw with 1 in. diam washer min, 1 in, loV min Type " pan head steel screw at the WG o0ordinor,pirplacked or gaiv steel, 3-IP2 im rinin Blankets (item 3) - Spray applied cellulose insulation tape and compound, item 5, optional for use witin Type USG BORAL DRYWALL SFZ LLC -Type SCX through the center hole Furring top of the ship, Lead batten strips, to have a purty of I 0. Frartning MamillesnO - Floor and Ceiling Runners depth, spaced a max Of 16 In, OC. Studs firknion-flt into alaterial, Ths fiber is applied with water to Interior , USGX) 40. Gypsum Boar& -As an aftemars to Tierra 4,4A, channels we friction fitted into cIO& fia.5% meeting Are Federal Specification 00-L-2011. - Not Shown - In lieu of Items I through 1 0 - For use Poor and ceiling filirl Studs to be cut 518 to V4 In, surfaces in accordance with the application instructions 4S, and 4C - Two layers Nom. 5fl5 in, thick ifirPsurn STUDCO BUILDING SYSTEMS - Grodes 'S C or D", Lead batten strips required behini with item 20 and 4C only, proprietary channel shaped kbui main assernitly height. supplied with the product Applied to completely fill the 4H, Gypsum Efisard* - (As an alternate to Items 4 panels applied vertically or horizontally. Honskilited edge joints and horizontal butt joints on opposite Slope of studs RESILMOUNT Sound Isolation Clips - Type A237R vertical joints of lead barked gypsum wallboard (Item 4J) runners, 1-1/4 in deep by min 3-W im wide fabricated 20. Framing M#mbeW- Steel Studs- As an enclosed c,avity. Minimum dry density of 4.3 pounds per cubic ft 4A. Gypsum BoarcF - (As alfiamme to Item 4) - Nom through 4G) - likehirvil IVS in, thick, 4 ft wide paneLs, , used not be staggered or backed by steel frefifing. and optional at remaining stud locations. from min 0.018 in, thick gaiv steel, attached to floor arid affernate to items 2 through 2C - For use with Item 1 D NU-V400L CO INC - Cellulose Insulation 516 in. thick gypsum panels wilt beveled, square or applied vertically and Secured as described in Item 4, Horizontal joints on the same aide need not bit I 0. Lead Discs or Tabs - (Not Shown, For Use With calling with fasteners spaced 24 in. CIC max. and 4G only, channel Shaped Studs, min 3-518 in, wide tapered edges, applied vertically or txuirrontalfy� vemon PASCO BUILDING PRODUCTS L L 0, BSA PASCO staggered, Men applied horzontally, both layfus Of Item 4E) - Used in 4eu ofor in addition to the lead CLARKDIETRJCH BUILDING SYSTEMS - CID fabricated from min O.OiB in. thick galv Steel, spaced a Joints centered over studs and staggered one stud cavity GYPSUM - Type QuIetRock ES gypsum board fastened to each side of framing with I in, BID. Steel Framing MembeW - (Opfidural, Nor Shown) batten strip (itairl or optional at other locations - Max ProTRAK max of 24 in. OC. Studs to be ad lr2 im less than on opposite slides of studs. Horizontal edge joints and long Type 8 steel mews spaced 8 in, 0C and staggered - - Furring channels and Sloet Framing Members as 3/4 in. diarn by max 0.12". thick lead discs assembly height L � �.l 1,1 10 �� Ste q,k 14`_l­A � M 4 in OC between layers an applied vertically, both described below in A__3 � � CLARMETRICH BUILDING SYSTEMS - CD 3C. Fiber, Sprairecr -As an a4emaw to Bell. an Blankets (Item 3) - Spray appli d It I fib Tn I Is Qrizon ) on oppo I a es San In he staggered or backed by steel framing. Panels I layers of gypsum board fastened to earn side of taming Pir over a screw ras 2 or max V2 in. by 1 A!4 in. by max 0. 125 in. thick lead tabs DMFCWBSLLC-PrOTRAK PTOSTUD fiber sappilled with wa�artocolm�,pzelyofiolil$teth,011een,�cI is 4,1' sed 's attached to steel Studs and floor runriarvil I in, tong 41, Gypsum Boardt' - (As an alternate to Items 4 through 4F) - For use with Items IS and 2E only, WE In, with I in, long Type 8 steel screws spaced 8 in, OC along a. Furring Channels - Fanned Of No, 25 MSG gaiv steel- Spaced 24 in, OC placed on gypsum boards(flam 4E) underneath screw DMFCWBS L L C - PrOSTUD cavity in accordance with the appli supplied witin !he product, The mir h a I I Type 5 steel screws spaced 6 in, OC when applied horizontally, Or 8 in- OC along vertical and bottom edges thick, 4 ft wide, attached to steel stud 5 and floor arid , vertical edges and 12 in, 00 in the field, Staggered 4 in, OC between layers- Screws spaced a max 12 im along perpendicular to studs, Channels locations prior to the installation of the screws. Lead discs or tabs to have a piarty of 99.9% meeting Me MBA METAL FRAMING - ProTRAK be 4.30 11>910, � I and 12 im OC in The field when panels are appAr ad ceiling track with I in. long, Type S slent screws spaced 8 in. OC, a" edges of board and 12 iii, OC in the field of Abe top and bottom edges of the wall. secured to studs as described in Item 6M. Ends of adjoining Channels Federal specification OQ­L�2011`, Grade "C' INTERNATIONAL CELLULOSE CORP - Corbar-pil. vertically. When used in widths offier then 48 in., gypsum NATIONAL GYPSUM CO - Type FSW ~sApped 6 in. and tied together with MSA METAL FRAMING - Prci I panels to be Installed horizontatly, the boarcL Joints oriented vertically and Staggered on RAM SALES L L C -Rom PraTRA K 30- Saba and StankeW - For use with Item 8 Neal ____ CeiiAwTiliD Gypsum INC - Type X, Type X-1, . opposite sides of the assembly, UNITED STATES GYPSUM CO - Type SCX 4P, Gypsum Boar& -As an aftemant to Item 4, For use with Item 3E, Baft and Blankets' - 518 in. trick 4 double strand of No, 18 AM Tialvarizedateal wfus- Gypsum board 10A, Lead Discs - (Not ,51roveri for use with Item 4J) - RAM SALES L L C - Ram PmSTUD in, thick, minimum 3.4 per mineral wool beds, friction fit Type C, Type X-2, Type EGRGI GlavRoc, GlasRoc-2, ft wide, installed as described in Item 4. attached to running channels as Mae &16 in. diam by max 0.140 in, thick lead discs oetween the studs and floor and coding runners, Type SAemFX, Eanil-Ute Type X-2 I UNITED STATES GYPSUM CO -Types ULIX described in Item 4.Not for use with compression allied or adhered over steel screw heads. STEEL STRUCTURAL PRODUCTS L L C - Tri-S ProTRAK $TEEL STRUCTURAL PRODUCTS L L C - Tri-S See Batts and Blankets (BZJZ) USAG BORAL DRYWALL SFZ LLC -Type SCX Items 4E 4J, or 4L Lead discs to have a purftyof 99.5% memning the Federal Specification 00-L-201f, Grade& 11, C or D"� PmSTUD category fix names of manufacturers, CGC INC - Types AP, C, IP-AR, IP­X1, IP-X2, WC -AR, I p. Steel Framing Membera* - UIJeed SCX. SHX, USGX. WHO or WRX (joint tape and 40, Gypsum Boand* - 314 in. thick, 4 ft *Ads, attached to attach furring channels (item 60a) to 11. Adhesive - Not Shown - (For use with Item 8) - `5 3E, Batts and Slankels� - For use sent Item 4P and compound. Rom 5, optional for use with Type USGX) 4J. Gypsum Board* - (Not Shown) - rAr, an alternate to steel studs and floor and ceiling track as described in studs, Clips spaced 48 in. OC, and Construction grade Scheer* applied In verfical, E I 1E, Framing Members" - Floor and Coiling Runners 2E. Framing Membenr' - Steel Studs -As an 4R. Placed in stud cavities. any min, $-112 in, thick fIt"Is fiber insulation hearing the UL Cliessificanon Marking as to Item 4 when used as the base layarcin one or both Item 4 with screw larginni increased As min I- IM in. PABCO BUILDING PRODUCTS L L C� OBA PASCO secured to studs with No.8 x 2,112 n onfarde, drywall screw through the center serpentine, nominal &8 in. ivide beads down the length of both vertical rlegasof Mineral and Fiber Board (Neurn 11 a - Not Shown - In lieu of items I through 1 D - For use with item 2E and 41 only, proprietary channel shaped alternate to items 2 Through 20 - For use with Item 1 E to Surface Burning Characiansfics and/or Fire CONTINENTAL BUILDING PRODUCTS OPERATING sides of wall, For direct attachmarrit onfir to steel studs Item 20) - Nom 618 in� thick lead boded gypsum GYPSUM - Type PG-13 We, Furring channels are friction fitted 8) . - I I runners, 1-1/4 in. deep by min 3-518 in. wide fabricated and 41 only, channel Maspedstuds, min 3-518 in, wide fabricated from min 0,01 8 In, thlck gRN srlaur� spaced a Resiallance. CO, L L C - Types LGF02A. LGFC6A, LGFC-CyA, LGFO-WID, CLLX panels with beveled, square or tapered edges, applied into dips, STIJDCO BUILDING SYSTEMS - 12. Wall and Partition Facings and Accessorient' - 1� - � from min 0.0 I 8 in, thick ga1v steel, attached to floor and max of 24 in, OC, Studs to be out V2 in, less than Sea Batts and Blankets (BKNV or verficafty. Vertical joints centered over duds and staggered min I stud cavity on opposite, sides of stud 5, Type SonusChAn (Optional, Not Shown) - For use with Items I to 11, 9 ceiling *tn fasterhars, spaced 24 Am CC nri assembly height WJZ) Categories far carries of Gypsum board secured to studs with 1,V4 in long Type 4R, Gypsum Boal an alternate to Item 4D. For items 2 to 2J, Item 3. Items 4 to 41, Item 5 and Item 6. ;I I I TELLING INDUSTRIES L L C - TRUE-TRACKka TELLING INDUSTRIES L L C - TRUE.SrUD"e Classified companies, GEORGIA-PACIFIC GYPSUM L L C - Types DAP r� 12 steel screws spaced 6 In, OC at perimeter and,12 use with Item 3E, Batts and Stantrals' - 518 in. thick. 4 I For maximum Ike rating of I hour, On one side of the wall, overthe first Layer of Gypsum Board (item 4 to Item M 9 I 3F Fiber, Sprayed" - As an alternate to Batts and DAPC,DGG,DS in. OC in the field To be used with Lead Eaten Ships ft viude, installed as described in Item 4. NATIONAL GYPSUM CO - Type FSLX BE, $feel Flaunting MembeW - (Optional, Not Shown) 41), install RefieXof membrane with The gold side facing Blankets (item 3) - Spray -applied witurose material. (see Item OA) or Lead Discs (see lierail MAYCO INDUSTRIES INC - Type X-Ray Shielded - Resilient Channels and Steel Framing Members as outwards Membrane installed with T50 staples spaced � 1 F. Framing Morenlathii - Flow and C41fing Runners 2F. Framing Members" - Steel Studs- As an The fiber is applied with watterto completely fill the i SAINT-GOS41N OYPROC MIDDLE EAST FZE - Type Gypsum described baltillir. 12 inches on center in both directions as per I . G - Not Shown - In lieu of Items I through 1 E - For use alternate to Items 2 Through 2E - For use with Item IF, channel shaped studs, min 3-518 in. wide fabricated from enclosed cavity in sloolardance with the application instructions supplied with the product, To facifficto it, i Gyproc, FireStop, Gyprac FireStop MR, Gyproc FireStoin 4S. Wall and Partition Facings and Acimilsories" - a. Resilient Channels - Formed of manuthicarer's instructions, seem in membrane to be overlapped by 2 inches, When RefleXor membrane is � 1 . vvith Item 2, channel shaped runners, 1-114 in, deep by inin 25 MSG steel, spaced a max of 24 in, CC. Studs be installation of the material, on- 9yon WTECH� Gyproo FireGlop ACTIVAin Gyproc rineStop MR ACTIVAir, GyprQc Fire5top M2TECH ACTIVAir, (As an alternate to SS In, thick board as outlined in Item No 25 MSG gaiv ideal, spaced 24 In. used an additional layer of Gypsum Board that is � � * min 3-5f8 rawadle fabricated from min 25 MSG steel, he out V2 in, iess than assambly height, netting may be attached by any means possible to Me Gyproc DuriaLine, Gyproc Dural-ine MR, Gyproc, 4K Gypsum Board* - (As an alternate to Item 4 and 4) - Nominal 1-3/8 in. thick, 4 ft wide panels, applied CC, and perpendicular to studs. identical to Me one used in the first layer and as specified I attached to floor and ceiling with fasteners spaced 24 in. KFRII (HONG KONG) LTD - Type KIRII outer face the studs, The maileral shall reach equil Id[iu in Mrsi WTECH, Gyproc Duratine ACTIVAI:r, Gyproc 4A, not for usawith Items I 0, 1 E, 2D and 2E) - No an, vertically at horizordalfiV. Fastened with 06 x 2 In. long Channels secured to studs as described in Item. 4 to Item 41 shall be Installed over the membrane. " 00 max. moisture content before the instatation of materials 711 DursUrs, MR ACTIVAir, Gyproo DuraLine M2TECH WIT in, thick gypsum panels with beveled, square or drywall screws spaced 5 im CC along the perimeter and in Item Is Ends of adjoining channels The additional layer of Gypsum Board to be Installed i,. 0 I KISH (HONG KONG) LTD - Type W Ril either tam of The studs, The mmannum dry density shall i ACTIVAir tapered edges installed as described in Item 4 and 4A. A 2 in, OC in the field, overlapped 6 in. and secured in place through the membrane to The, stud as Specified in Item 4 9 be 5 79 Itnalli � CGC INC - Type ULX PASCO BUILDING PRODUCTS L L C, OBA PASCO with two No, 8 15 x V2 in, Plailiter to item 41 except the fastener length shall Lie increased iii 2G� Fransing liibrnbisre� - Steel Studs - Not Shown APPLEGATE KOLDMIGS L L C - Type I SAFE I GYPSUM -Type QuietRock 545 Modified Truss screws spaced 2-1/2 in, by a minimum of 518 inch. Instali Batts and Blankets in E - In lieu of Item 2 through 2F - For use with Item IG� Applegate Fired Rated Material I VA 43YPSUM PRODUCTS POL - Type X, Type 0 from the winter of ft overap. Gypsum the stud cavity as per Item �A, On tha other side of the I IG. framing MembeW - Floor and Ceiling Runners Proprietary channel shaped aftics, minimum 3-5/8 in. UNITED STATES GYPSUM CO - Type ULX pearc attached to resilient channels. as wall, prior to the Installation of the Gypsum Board, install 11 I - Not Shown - In lieu of Items 1 Through I F - For use wide, Studs to be cut V2 n less Stan the assembly ; described in Item 4, Not for use vern Resilient Channeig 0% per Item 6. Over the Resident i with Item 2, channel shaped runners, I-V4 in, deep by height. � UNITED STATES GYPSUM CO - Types AR, C, FRX-G, 5. Joint Tape and Compound - Vinyl, dry or prerribed Items 4F, 4J, or 4L Channels install 314 inch thick SONOpsAr panel secured I min 3-518 in. wide, attached to floor and ceiling with fasteners Spaced 24 in, OC maxi� � 4, Gypsum Board* - 6M In, thick, 4 ft Woe I I steel studs and floor and ceiling track with 1 -0 "I to 1 i IP-AR, IP-X1, W-X2, IPC-AR, SCX. SHX, WRC, WRX, LISS MEXICO 3 A DE C V - Type ULX joint compound, applied in two coats to joints and screw heads; paper tape, 2 am wide, embedded in first layer of b. Steei Framing Meembere -Used to to Vie Resilient Channels win drywail Screws and I washers spaced at 16 in. OC an the perimeter of the I i STUDCO BUILDING SYSTEMS - GROCSTUD Track � Type S steel screws spaced 8 iri. OC. along ad I : USGX (Joint tape and compound, Item 5, Optional for use with Type USGX) attach resilient channels (item 6Ea) to panel and B An, OC tn the field of The panel. Over the � a studs, Clips spaced 48 in. OC., and SONOpan panel install the sarms Gypsum Board as I IH, Floor and Coiling Runners - (Not Shown) - I : "Ofided in Item 4 to Item 41,MM All lastener length - � Channel shaped, fabricated from man 0.02 In. gaiv steel -- I I min width to accomalodatc stud Size, with min I in, tong 0 - I legs, for use vift "As speofied below and fabricated - 9 -� 0 from min 0,02 in. gahr steel or ticker, attached to floor � I and ceiling with fasteners Spaced max 24 in. OC, 1!!! MARINOAMARE, DfVOF WARE INDUSTRIES INC - I VpWOre Track VT100 FUSION BUILDING PRODUCTS - Vipar20"IW Track I VTIOO � . IMPERIAL MANUFACTURING GROUP INC - . �� Mper2OTO Track VTI00 d W 11 Framing Members'l - Floor and Ceding Assenara I- Not Shown - In lieu of Item I - For use with Item 0 2H, proprietary channel shaped runners, 1-1!4 In. wide by Z § linin 3-518 in. deep fabricated from min 0,020 in, thick gaily 9 I - - W V - I I - ��, 1�� 1�__, F11 F C Mile, In- 7 ;�JM:AIM ("r 11 4 ;l! 4 t2 4 � t�t 1� ;� Q tl) "A kl Z t A3 ;� t bio� It � ;� r is 0 - g C4 ;Z M I Go C3 � w 1-: � :C I.- _1 Lf) (J) 5 LL �t COD =) U) a 04 ri f- 9 (6 5 r- Q D I I Isr _J � r, �- LL (y) F_ 0: 0 (L CHRISTOPHER J. HAMMEL FIL PE #81811 _J _J < �: Ii UJ V) M T_ 06 N V__ * _J a- UJ Z 3: 0 0� 0 'fj,l a � W 0 -1 -1 < 3: 0 LLI F- 9 F_ Z Lu 2 W � � 2 � W W % OL M 0 A If EL Ii2 LILT 0 2 i M Lu M _1 Z ") 6 1: n Ii Ce 2 2 0 0 0 O. de 0 u- 0 LLI It 9 W ar 01. 1; il 8 . � S J .2 � b . i 2 V 9 t . a UJ ,_ _J a I =) 1 1 0 - . a W g As As. a: , i . . 0 i It I is a W i I � 11 Z� i I , � I A 0 � 91 T ,15l Z t F > 0 � E W a A .2 I � I 3- W I � 0 .- cl) I I LLI I I I I I I I 1 � . . . 12 , � 0 I I I I I I I I 1 1 1 1 0 0 I -SA Ali e . W I I I I I I I I I I I I 9 � � ­r - - i I 1�1 _r _r _r _r _r a r rl _r �l _r _r �l �l � 151 I I . � . � - - - - - ! 8 d 11 ad (7) a � C-4 . I A � I I Z 4,+.)I+)�W� I I.L.L� 4 w ft PROJECT* 191031.CP12.dW9 9 t;- ig 9 1. DATE: February 26 201 1 'I Is SCALE: ASSIHOWN I a I DESIGNED BY: -_ 11 DRAWN BY: - I 01 .ne CHECKED BY� --- M I SHEETTITLE 9 I � I I . W 2 . F6 RATED WALL DETAIL . -. E E 0 A! 41_9-�� r, k 0 ff"i!A, n, , � 9 W N , 0 1 1 W !I __ W E g I 0 2 rr I SHEET 2 of 2 1 P I < .