HomeMy WebLinkAboutEVALUATION REPORT RIDGE VENTMIAMI-DADE COUNTY
MIAMI QADE PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786)315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Lomanco, Inc.
2101 West Main Street
Jacksonville, AR 72076
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Lomanco Lo-OmniRidge LOR94 Ridge Vent
TRI-BUILT® Lo-OmniRidge LOR94 Ridge Vent
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA No. 19-0508.02 and consists of pages 1 through 5.
The submitted documentation was reviewed by Freddy Semino 0
MIAMI•DADE C0NOA No.: 19-1217.05
• ►, Expiration Date: 09/04/23
Approval Date: 01/23/20
Page 1 of 5
ROOFING COMPONENT APPROVAL
Category:
Roofing
Sub -Category:
Ventilation
Materials:
Plastic
Minimum Slope:
3:12
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT
Test
Product
Product
Dimensions
Specification
Description
Lomanco Lo-OmniRidge
4' x l l %2" x 3/4"
TAS 1 OOA
Ridge ventilation system
(LOR94) Ridge Vent
Min. thickness 0.75"
TRI-BUILT' Lo-OmniRidge
4' x 11'/z" x 3/4"
TAS 100A
Ridge ventilation system
(LOR9-4) Ridge Vent
Min. thickness 0.75"
TRADE NAMES OF PRODUCTS MANUFACTURED BY OTHERS
Test Product
Product Dimensions Specification Description
Roofing Nails Min. 12 ga. TAS 114 Appendix E Corrosion resistant annular ring
1 3/4" shank nails
MANUFACTURING LOCATION
1. Jacksonville, AR
EVIDENCE SUBMITTED
Test Aaency/Identifier
PRI Construction Materials Technologies, LLC
Name
TAS 100
TAS 100(A)-95
ASTM G155
ASTM D638
ASTM E1252
ASTM D635
ASTM D 1929
ASTM D2843
Report
LOM-003-02-01
LOM-029-02-01
LOM-047-02-01
LOM-047-02-01
LOM-026-02-01
LOM-033-02-01
LOM-034-02-01
LOM-041-02-01
Manufacturer
Generic
Date
01/15/03
08/15/13
04/15/16
04/15/16
05/23/13
03/28/14
03/28/14
06/05/14
MIAMI•DADE COUNTY
NOA No.: 19-1217.05
�� . • • • Expiration Date: 09/04/23
Approval Date: 01/23/20
Page 2 of 5
APPROVED APPLICATIONS
Tradename: Lomanco Lo-OmniRidge (LOR94) Ridge Vent
TRI-BUILT® Lo-OmniRidge (LOR9-4) Ridge Vent
System Type: Mechanical attachment of ridge vent system over composition shingles.
Slot: Truss Construction: Cut shall be 1-1/4' wide and 6" shorter at each end than the total
length of the ridge vent to be installed.
Ridge Pole Construction: Cut shall be 2 3/4"" wide and 6" shorter at each end than the
total length of the ridge vent to be installed.
Installation: Connect all the male tabs with the female tabs across the entire roof before vent is
nailed down. This will ensure that the vents are as straight as possible. Mark proper
alignment and end line for vents with chalk; snap a chalk line down both sides of the
ridge at a distance of 5 1/2" down from the peak as shown in the manufacturer's
installation instructions.
Starting with the first vent, nail the vent down with roofing nails placed 12" on center at
manufacturer pre -marked locations. Use nails of sufficient length to penetrate through
the sheathing a minimum of/]6" or at least 1" into wood plank decking thicker than I".
If the vent is being installed in cold weather, leave a 1/8" gap between each vent to allow
for expansion in hot weather. Continue to nail the remaining pieces down taking care to
keep the vents as straight as possible. The last piece may be cut to the proper length.
Ridge Shingle: Using nail lines provided on top of vent, install the cap shingles directly to the vent, in
compliance with the shingle manufacture's Notice of Acceptance (NOA) and
installation instructions, using roofing nails of sufficient length to penetrate through the
sheathing a minimum of 3/16" or at least 1" into wood plank decking thicker than 1".
Ventilation Calculations: Refer to manufacturer's published literature.
MIAMI•DADE CO
NOA No.: 19-1217.05
• � • I UNTY Expiration Date: 09/04/23
Approval Date: 01/23/20
Page 3 of 5
LIMITATIONS
1. Refer to applicable Building Code for required ventilation.
2. Ridge Vent shall comply with applicable Building Code
3. Lomanco Lo-OmniRidge (LOR9-4) Ridge Vent and TRI-BUILT® Lo-OmniRidge (LOR9-4) Ridge Vent shall
not be installed in conjunction with Gable vents.
4. Lomanco Lo-OmniRidge (LOR9-4) Ridge Vent and TRI-BUIL,T' Lo-OmniRidge (LOR9-4) Ridge Vent shall
not be installed on roof hips.
Lomanco Lo-OmniRidge (LOR9-4) Ridge Vent and TRI-BUILT® Lo-OmniRidge (LOR9-4) Ridge Vent shall
not be connected at ridge intersection, or within 12" of any side wall or roof protrusion, with a ventilation slot
clearance of 12" from such obstructions.
6. Lomanco Lo-OmniRidge (LOR9-4) Ridge Vent and TRI-BUILT® Lo-OmniRidge (LOR9-4) Ridge Vent shall
not be installed on roof mean heights greater than 33 ft.
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
NOA No.: 19-1217.05
Expiration Date: 09/04/23
Approval Date: 01/23/20
Page 4 of 5
DETAIL DRAWINGS
4-
D� 4f
D � 1¢1✓
l3 4
t4-
I—
-4
i—�-3 d--4
-4 j
E
4 , F i-
4
48"
LomANco Lo-OmNiRIDGE LOR94 RIDGE VENT
TRI-BUILT® Lo-OmNiRIDGE LOR94 RIDGE VENT
END OF THIS ACCEPTANCE
MWMFDAQE COUNTY
NOA No.: 19-1217.05
• • 0 0 Expiration Date: 09/04/23
Approval Date: 01/23/20
Page 5 of 5