Loading...
HomeMy WebLinkAboutAPPROVED DESIGN PRESSURES (1)FLOFVALID FOR ONE (1) PERMIT ONLY#C:\Users\gabriel\Engineering Express\Production - Documents\Projects\_Master Plan Sheet Store\Windows-Doors-Shutters\400 Wind Charts\_Resources\2020 FBC\20-400 Series C-C Wind Charts.dwg12/30/2020 - 10:48am gabriel &23<5,*+7(1*,1((5,1*(;35(66‹1FRANK BENNARDO, PEPE0046549 C/A #9885N.T.S.ASCE 7-16 1. THIS DOCUMENT IS ONLY VALID WITH AN ORIGINAL SIGNATURE & RAISED SEAL OR DIGITALLY SEALED WITH DATE-GEOGRAPHIC AREA & PERMITTEE LIMITATIONS. 2. TABLES ARE TO BE USED IN CONFORMANCE WITH (ASD) "ALLOWABLE STRESS DESIGN METHODOLOGY" PER ASCE 7-16 SECTION 2.4.1 AND CHAPTER 30 PART 1 OR 3, USING THE CRITERIA AS OUTLINED HEREIN. 3. DESIGN IS BASED ON THE ULTIMATE 3 SECOND GUST (WIND VELOCITY) FOR THE WIND VELOCITY & EXPOSURE SPECIFIED. 'WORST CASE' CRITICAL CONDITIONS SHALL BE ASSUMED FOR DETERMINING PRESSURE RATINGS. 3.1. ASCE 7-16 RISK CATEGORY IS INDEPENDENT OF THESE RESULTS. FIND RISK CATEGORY VELOCITY TO BE LESS THAN THE RATED LIMITING ULTIMATE WIND VELOCITY REFERENCED ABOVE. 4. TOPOGRAPHIC FACTOR Kzt=1.0 FOR FLAT TERRAIN USE ONLY. NO HILLS SHALL BE NEARBY AREA. 5. INTERNAL PRESSURE COEFFICIENT (GCpi=+/-0.18) - FOR USE WITH AN ENCLOSED STRUCTURE ONLY. 6. VERIFY USE OF Kd (DIRECTIONALITY FACTOR REFERENCED ABOVE) WITH LOCAL BUILDING DEPARTMENT. 7. HVHZ = HIGH VELOCITY HURRICANE ZONE (BROWARD & DADE COUNTIES). 8. TABLES ARE FOR VERTICAL SURFACES ONLY & FOR ALL ELEVATIONS ABOVE SEA LEVEL (Ke=1.0). 9. THIS MASTER PLAN SHEET IS GENERIC IN NATURE AND DOES NOT SERVE AS A SITE-SPECIFIC DOCUMENT. 10. THIS DOCUMENT ILLUSTRATES ALLOWABLE DESIGN WIND PRESSURES (ASD) AS LISTED. APPLICATION OF THESE TABLES AND CORRESPONDING WIND VELOCITY, EXPOSURE, & OTHER COEFFICIENTS LISTED HEREIN SHALL BE DICTATED AND VERIFIED BY THE GOVERNING BUILDING DEPARTMENT AND PERMIT HOLDER. NO WARRANTY FOR APPLICABILITY OF THE USE OF THESE TABLES IS OFFERED HEREIN. 11. THIS SPECIFICATION DOES NOT OFFER ANY PRODUCT APPROVED CERTIFICATION. REFER TO ANY SEPARATELY SUBMITTED TEST CRITERIA AND OTHER APPROVALS FOR DESIGN & INSTALLATION INFORMATION AND APPLICABILITY OF THESE TABLE VALUES WHICH IS TO BE VERIFIED BY OTHERS IN ACCORDANCE WITH GOVERNING CODES. 12. ADHERE TO ALL LOCAL IMPACT PROTECTION SYSTEM ORDINANCES. 13. NO CERTIFICATION IS OFFERED FOR THE INTEGRITY OF THE HOST STRUCTURE. 14. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. 1. IDENTIFY THE ZONE OF THE OPENING AS INTERIOR (ZONE 4) OR EXTERIOR (BUILDING CORNER, ZONE 5) PER THE FIGURE BELOW LEFT OR INFORMATION PROVIDED TO YOU BY OTHERS. 1.1. ANY QUESTIONABLE OPENING IS TO BE CONSIDERED THE MORE CRITICAL (EXTERIOR) ZONE 5. 2. IDENTIFY THE BUILDING MEAN (AVERAGE) ROOF HEIGHT FROM THE LOWEST GROUND ELEVATION. IF THE MEAN ROOF HEIGHT CANNOT BE IDENTIFIED, USE THE PEAK (HIGHEST) ROOF HEIGHT. 2.1. ALWAYS ROUND UP ROOF HEIGHTS TO NEXT TABLE VALUE. 2.2.9$/,')25$//522)6/23(6)256/23(6ƒ6(($1(1*,1((5)255('8&7,216 3. CALCULATE THE TRIBUTARY AREA OF THE OPENING IN QUESTION AS THE GREATER OF (HEIGHT * WIDTH) OR THE SPAN LENGTH (HEIGHT) * AN EFFECTIVE WIDTH OF 1/3 THE HEIGHT (HEIGHTð / 3). 3.1. USE THE AREA BETWEEN STRUCTURAL OPENINGS ONLY- THIS INCLUDES AREAS BETWEEN STRUCTURAL MULLS, COLUMNS, ETC. 3.2. IF THE TRIBUTARY AREA OF AN OPENING CANNOT BE IDENTIFIED, THE SMALLEST (10 SQUARE FEET) SHALL BE USED. 3.3. ALWAYS ROUND TRIBUTARY AREA DOWN TO THE SMALLER TABLE VALUE. FOR LARGER TRIBUTARY AREAS THAN PUBLISHED, USE THE LARGEST PUBLISHED VALUE. 4. READ OFF POSITIVE AND NEGATIVE PRESSURES FOR USE AS REQUIRED BY THE LOCAL MUNICIPALITY IN ACCORDANCE WITH CODE. 5. FOR SITUATIONS THAT REQUIRE Kd=1.0, TABLE VALUES ARE UNDER-DESIGNED BY A FACTOR OF 1.18. VERIFY Kd REQUIREMENTS WITH LOCAL MUNICIPALITY PRIOR TO TABLE USE. 7th EDITION FLORIDA BUILDING CODE (2020) ASCE 7-16 'ASD' DESIGN PRESSURES FOR COMPONENTS AND CLADDING GENERAL NOTES: INSTRUCTIONS FOR TABLE USE: EAVE ROOF HEIGHT aa 5 55 5 ISOMETRIC PEAK ROOF HEIGHT MEAN ROOF HEIGHT (MRH) 5 4 5 a a INTERIOR ZONE 4 , EXTERIOR CORNER ZONE 5 & MEAN ROOF HEIGHT (MRH) EXPLAINED a= 10% OF LEAST HORIZONTAL DIMENSION OR 40% OF MEAN ROOF HEIGHT (MRH), WHICHEVER IS SMALLER, BUT NOT LESS THAN 4% OF LEAST HORIZONTAL DIMENSION OR 3FT. USE CORNER ZONE 5 IF AT ALL IN QUESTION. CONSULT AN ENGINEER FOR A MORE SPECIFIC INTERPRETATION IF REQUIRED. 44 20-413MRH = MEAN ROOF HEIGHT WIND VELOCITY IS Vult MEAN ROOF HEIGHT (MRH) ELEVATION COPIES NOT VALID FOR PERMITDIGITAL SEAL AREA ONLY (IF APPLICABLE)NOT TO BE USED FOR SITE SPECIFIC ADDRESS1 1 aa LEAST HORIZONTAL DIMENSION 55 5 4 5 4 55 COMPLEX CORNERS PLAN VIEW WIND VELOCITY = 170 MPH EXPOSURE 'C' DZ,чϲϬΖ BASED ON Kd = 0.85 INTERIOR ZONE 4 PRESSURES EXTERIOR ZONE 5 PRESSURES ENCLOSED STRUCTURE, FLAT TERRAIN Mean Roof Height DESIGN PRESSURES (PSF) - ZONE 4 Mean Roof Height DESIGN PRESSURES (PSF) - ZONE 5 Tributary Area (Sq Ft)Tributary Area (Sq Ft) 10 20 30 40 50 10 20 30 40 50 ϬʹϭϱĨƚ -41.0 -39.3 -38.3 -37.6 -37.0 ϬʹϭϱĨƚ -50.6 -47.2 -45.2 -43.8 -42.7 +37.8 +36.1 +35.1 +34.4 +33.8 +37.8 +36.1 +35.1 +34.4 +33.8 18 ft -42.6 -40.8 -39.8 -39.1 -38.5 18 ft -52.6 -49.0 -47.0 -45.5 -44.4 +39.3 +37.5 +36.5 +35.7 +35.2 +39.3 +37.5 +36.5 +35.7 +35.2 20 ft -43.6 -41.7 -40.7 -39.9 -39.4 20 ft -53.8 -50.1 -48.0 -46.5 -45.4 +40.2 +38.3 +37.3 +36.5 +36.0 +40.2 +38.3 +37.3 +36.5 +36.0 25 ft -45.7 -43.8 -42.6 -41.9 -41.3 25 ft -56.4 -52.6 -50.3 -48.8 -47.5 +42.1 +40.2 +39.1 +38.3 +37.7 +42.1 +40.2 +39.1 +38.3 +37.7 30 ft -47.4 -45.5 -44.3 -43.5 -42.9 30 ft -58.6 -54.6 -52.3 -50.7 -49.4 +43.7 +41.8 +40.6 +39.8 +39.2 +43.7 +41.8 +40.6 +39.8 +39.2 35 ft -49.0 -47.0 -45.8 -44.9 -44.3 35 ft -60.5 -56.4 -54.0 -52.3 -51.0 +45.2 +43.1 +42.0 +41.1 +40.5 +45.2 +43.1 +42.0 +41.1 +40.5 40 ft -50.4 -48.3 -47.1 -46.2 -45.5 40 ft -62.2 -58.0 -55.6 -53.8 -52.5 +46.5 +44.4 +43.1 +42.3 +41.6 +46.5 +44.4 +43.1 +42.3 +41.6 45 ft -51.7 -49.5 -48.3 -47.4 -46.7 45 ft -63.8 -59.5 -57.0 -55.2 -53.8 +47.6 +45.5 +44.2 +43.3 +42.6 +47.6 +45.5 +44.2 +43.3 +42.6 50 ft -52.8 -50.6 -49.3 -48.4 -47.7 50 ft -65.2 -60.8 -58.3 -56.4 -55.0 +48.7 +46.5 +45.2 +44.3 +43.6 +48.7 +46.5 +45.2 +44.3 +43.6 55 ft -53.9 -51.7 -50.3 -49.4 -48.7 55 ft -66.5 -62.1 -59.4 -57.6 -56.1 +49.7 +47.4 +46.1 +45.2 +44.5 +49.7 +47.4 +46.1 +45.2 +44.5 60 ft -54.9 -52.6 -51.3 -50.3 -49.6 60 ft -67.8 -63.2 -60.5 -58.6 -57.2 +50.6 +48.3 +47.0 +46.0 +45.3 +50.6 +48.3 +47.0 +46.0 +45.3 1 2 4 3 1 2 4 3 2 2 WIND FLOW 'ASD' IS ALLOWABLE STRESS DESIGN AND SHALL MATCH SUCH LIMITING DESIGN PRESSURES ON ANY CORRESPONDING DOCUMENTS NOT TO BE USED OR MATCHED WITH 'LRFD' OR 'ULTIMATE' DESIGN LIMITING PRESSURES VISITecalc.io/windTO LEARN MOREABOUT THISDOCUMENT &FOR ADDITIONALENGINEERINGFOR PERMIT.VISIT ecalc.io/windOR SCAN CODEWITH YOUR PHONECOPIES NOT VALID FOR PERMIT COPIES NOT VALID FOR PERMITORIGINAL SIGNATURE & RAISED SEAL OR DIGITAL SEAL ONLY VALID FOR USE.