Loading...
HomeMy WebLinkAboutInsulation . 3 h PLANNING& DEVELOPMENT SERVICES, BUILDING&CODE REGULATION DIVISION Ajun aian-r •aS 2300 Virginia Ave,Fort Pierce, FL 34982 !772-462-1553 Fax 7724 eulmiu„ad a INSULATION INSTALLATION C .RTIFICATIQN.-= Building Permit# ® /� ®S�i e Address: Street —� City State Zip The undersigned hereby certifies that insulation has been ins�'dTf', in the above-described property to meet the minimum requirements for R-Value of the Florida Energy Efficienc�Code in accordance with the approved plans and specifications,as follows: 1. Exterior walls have been insulated with (check one from list)to a _ spray on cellulose thickness of 414 inches,which thickness,according to a Fiberglass batts manufacturer will yield an 'R' value of at . c Rock Wool Batts per square feet Aluminum Foil Polyurethane Polystyrene Other 2." Ceilings have been insulated with (check one-from list)to a Thickness of e inches,which thickness,according to the Fiberglass blankets manufacturer will yield an 'R' ,value of ; at bags Fiberglass loose Fill per square feet 4�c P .h-4* Rock Wool bla-nkets Manufacturer: :J l 3IA Rock Wool loose fill Cellulose loose fill Other 3. Interior/Adjacent Tenant Walls have been insulated with to a thickness of inches which,according to the manufactu er,will yield an 'R'value Of Manufacturer: 4. Garage partition walls of conditioned living area have been insulated with to A thickness of inches which,according to the manufacturer,,will yield an 'Ff value Of Manufacturer: The following areas have not been insulated: Insulation Contractor General Contractor/Builders 0C- J/9e Company Name CC number o any Name CC number Contractor's Name License# Contractor's Name License# Contractor's Signature Date '�/� Contractor's Signature Date JohnsManville C1�mae Pro �70 i I EpRMAUDEHY AN a. sue., J'.. J CLIMATE PRO ATTIC COVERAGE CHANT t R VALUE MINIMUMINSTALI ED SETTtLE THICfCfa� SS MAXIMUM NET MINIMUM WEIGHT BAGS EE(�?OO SQ FT COVERAGE (Ibs,/t {Ix•sgft�'fIBTU) THICKNESS�m? (m Expected thickness Minrmtm)nu, berofy Contents of this bag The weight per sq.ft. To obtain an insulation Installed insulation after long-term settling bags per 1,000 sy.�' should not cover of installed insulation resistance(R)of should notbe lessthan: has OCCUred of net area`. more than: should not be less than: 11 4.2 4.2 4.8 208 0.14 13 4.9 4.9 5.7 176 0.17 19 7.0 7.0 8.4 119 0.25 22 8.1 8.1 9.8 0.30 26 9.4 9.4 11.7 85 0.35 30 10.8 10.8 13.7 73 0.41 '38 13.4 13.4 1 . 44 15.7 15.3 297 48 49 16.9 16.9 23.4 43 0.70 60 20.2 20.2 29.2 34 0.88 The manufacturer recommends that the insulation be installed at these minimum thicknesses and maximum coverages to provide the levels of insularion thermal resistance(1l-value)shown. CLIMATE PRO CAVITY WALL (SIDEWALL) COVERAGE CHART THERMAL RESISTAWCE Aj11Nli1JIUM fHIGKNESS DENSITY 0�II�SIlLATIUN MAXIMUM COVI=RAGE MII111MUM 1NEIGHT To abtaln insulatron Installed rnsulart4rk Jnstalled titsufa0on Contents oft7xe bag INerght resistance of sfiafltot he lessthan shall notbs less than shall not cnvermore'than should riot be less than F R-VALUE INCHES Ib/ft' ft1 Ib/ft, 15 3.5 1.5 69 0.44 24 5.5 1.5 44 0.69 31 7.25 1.5 33 0.91 40 9.25 1.5 26 1.16 16 3.5 2.0 51 0.58 25 5.5 2.0 33 0.92 32 7.25 2.0 25 1.21 41 9.25 2.0 19 1.54 The manufacturer recommends that the insulation be installedat these minimum thicknesses and maximum coverages to provide the levels,of insulation thermal resistance(fl-value)shown. Visit our website at www.JM.com or call 800-654-3103 1 Building Insulation Division P.O.Box 5108 I Denver,C0 80217-5108 Technical specifications as shown in this literature are intended to be used as general guidelines only.Please refer to the Safety Data Sheet and product label prior to using this product.The physical and chemical properties of thermal and acoustical fiberglass insulation listed herein represent typical,average values obtained in accor- J� dancewithacceptedtestmethodsandaresubjectionormalmanufacturingvariations.Theyaresuppliedasatechnicalserviceandaresubjecttochangewithoutnotice. Anyreferences to numerical flame spread orsmoke developed ratings are not intended to reflect hazards presented by these orany other materials underactual fire con- ditions.Check with the sales office nearestyou for current information.All Johns Manville products are sold subjectto Johns Manville's standard Terms and Johns Manville Conditions,which includes a Limited Warranty and Limitation of Remedy.For a copy of the Johns Manville standard Terms and Conditions or for information an otherJohns Manville insulation and systems,vish www.im.com/terms-conditions or call800-654-3103. BIC-261 1/21 ©2021 Johns Manville.All Rights Reserved. t f f(Hl�lgd�l.li?EIOfi= F16�ET' F1SE�fGLASS ll►lSIJILAFIIsit re , MggA p" to f Johns Manville,a Berkshire Hathaway company,wa.jounded iti 1858 . Our ovVnershi by Berkshire Hathaway, one of the..most'admired cr.npanies in the world and one of the most financially secure, allows JM to invest forihe f i -T�" y 'tom s enables JM to � continue delivering the broadest range of insulatin' pTektets in the industry and ' s offering innovative solutions that meet your) e s. ' DESCRIPTION Johns Manville Formaldehyde-free'"Climate Pro blow-in loose-fill fiberglass insulation p r, s blown into attics, nonconforming spaces and is a premium alternative to cellulose. ft� hard-to-reach areas, like corners, edges and around framing.When it's applied to the s recommended thickness-nd SN6cifications, it improves energy efficiency..And unlike s cellulose, it won't settle, decay or provide food for animals or microbes. It's effective for the life of the home. USE oAttics—can be installed up to a R-70 over%z" (13 mm)ceiling drywall without exceeding ceiling weight limits, PERFORMANCE ADVANTAGES S Nonconforming spaces—insulation sprays out of the hose several feed, filling in Formaldehyde-free:will not off-gas large areas and small gaps quickly and completely. formaldehyde in the indoor environment. -Wall cavities—can be installed in walls using the netted blow-in applications. Thermally Efficient:provides effective resistance to heat transfer. Unlike INSTALLATION resistance products,JM Climate Pro Equipment for JM Climate Pro insulation installation is engineered for professional use. insulation does not settle, for no loss Contact your local JM sales representative for an authorized contractor. of R-value after installation, RECOMMENDED STORAGE AND TRANSPORT Sound Control:reduces transmission of Store insulation indoors. Keep insulation clean and dry at all times. When transporting, sound through exterior and interior walls, cover completely with a waterproof tarpaulin as necessary, and floor and ceiling assemblies for superior sound control. SPECIFICATION COMPLIANCE—CLIMATE PRO INSULATION Fire Resistant and Noncombustible: ASTM C764, Type I See Specification Compliance. Surface Burning Characteristics (ASTM E84 and CAN/ULC 5102.2) Noncorrosive:does not accelerate •Flame Spread 5 or less corrosion of pipes,wiring or metal studs. • Smoke Developed 5 or less: Critical Radiant Flux(ASTM E970): Greater than 0.12 W/cm2 (0.11 Btu/ft2•s) Resilient Inorganic Glass Fibers:cannot Combustible Characteristics (ASTM E136): Pass rot, mildew, or otherwise deteriorate. Water Vapor Sorption (ASTM C1104): 5% or less by weight Easy to install:quickly insulates attics Odor Emission (ASTM C1304): Pass or spaces of any size or shape without Corrosiveness(ASTM C764): Pass cutting or fitting. Fungi Resistance(ASTM C1338): Pass Complete coverage:effective in tight VOC Emissions (ES Section 01350): Pass spaces,areas with large amounts of cross-bridging or areas with small gaps BUILDING CODE COMPLIANCE AND FIRE HAZARD CLASSIFICATION and voids. IBCIIR� Flame"Sp"r,`.aid Smoke Deue[oPed*x. EllIE131alf AND Edi9lilR011lllflENT Climate Pro Insulation All Types/ 5 5 All Types 'Meets FHC 25/.50 sperification perASTM E84 and CAN/ULC-S1022 a 'GRffNGUARD ceriifirztivn is natintended fvrresidential en ironments.instead,the certification is intended only for buildingsmeetingASHRAE62.1-2010 cornmemial building ven- tilation rates.This certification is proof that the product meets the GREENGUARD Environmental Institute's indooreir quality standards and product emission standards for vocs. Visit our website at www.JM.com or call 800-654-3103 Building Insulation Division P.O.Box 5108 1 Denver,CO 80217-5108