Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
GENERAL INFORMATION SECTION A
% LU I Section A (General Information) Master Permit No. Process No. Contractors Name: SOUTHERN PRO RESTORATION, LLC License # CCC1329584 Job Address 5309 HUMMINGBIRD_ WAY ROOF CATEGORY )(Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles Asphaltic Shingles ❑ Metal Panel/Shingles Mood Shingles/Shakes ❑ New roof ❑ Repair Low Slope Roof Area (SF) 300 ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ Maintenance Reroofing ROOF SYSTEM INFORMATION Steep Sloped Roof Area (SF) 2000 ❑ Recovering Total (SF) 2300 Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. Pcv,:,ered by f2 roofr D i a arf1 5309 Hummingbird Way, Fort Pierce, FIL 34951, USA This report was prepared by Ian Robles, Copyright ,J 2021 Roofr.com I All rights reserved. 2 Povv;ered by 0 roof All SLi Jc Ui 1S _f'-)Un-imalry 5309 Hummingbird Way, Fort Pierce, FL 34951, USA N-" ensure gents Total Roof Area 2,402 sqft Total Roof Facets 7 facets Predominant Pitch 5/12 Total Eaves 206ft Total Valleys 26ft 2in Total Hips 54ft 6in Total Ridges 61ft 7in Total Rakes 61 ft 10in Total Wall Flashing Oft Total Step Flashing Oft Total Transition 25ft 1 in Total Unspecified Oft Hips + Ridges 116ft 1 in Eaves + Rakes 267ft 9in Pit h f 5/ 12 Area (sgft) 326 2,076 Squares 3.3 20.8 Waste % % A 0% 12% 115 % 1, 7 % 2DO% 22% Area (sgft) 2,402 2,643 2,691 2,763 2,811 2,883 2,931 Squares 24.1 26.5 27.0 27.7 28.2 28.9 29.4 We've calculated the waste percentages you might expect forth is job. A number of factors are involved in determining which waste percentage to use including; how complex the roof is, and your roof application style. These numbers only include the roof area. You will also need to calculate the quantity of materials you will need for hips, valleys, ridges, and starter lengths.6 This report was prepared by Ian Robles, Copyright © 2021 Roofr.com ( All rights reserved. ®T. L Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: GAF -ELK Product Approval No.: 5680-R30 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1': -75 Zone 1: -75 Zone 2: Zone 3: Max. Design Pressure, from the specific product approval system: W-71 Deck: Type: PLYWOOD Gauge Thickness: 7/16 Slope: 1112 Anchor/Base Sheet & No. df Ply(s): SASE 1 Anchor/Base Sheet Fastener/Bonding Material: SELF ADHERED Insulation Base Layer: NA Base Insultation Size and Thickness: NA Base Insulation Fastener/Bonding Material: NA Top Insulation Layer: NA Top Insulation Size and Thickness: NA Top Insulation Fastener/Bonding Material: NA Base Sheet(s) & No. of Ply(s): NA Base Sheet Fastener/Bonding Material: NA Ply Sheet(s)' & No. of Ply(s): GAP 1 Ply Sheet Fastener/Bonding Material: SELF ADHERED Top Ply: LIBERTY CAP SHEET Top Ply Fastener/Bonding Material: NA Surfacing: GRANULATED Fastener Spacing for Anchor/Base Sheet Attachment: **SELF ADHERED Zone ocVLap, #Rows.... ® "� Zone 1:____." oc # Rows ® "o0 Zone 2---- " oc# Rows "oc Zone 3:— " oc# Rows_ " oc " Number of Fasteners er insulation Board: Zone 1'• Zo 1: Zone 2• Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16.. ac,.,c,-`-J! by 0 roof 5309 Hummingbird Way, Fort Fierce, FL 34951, USA Eaves 2O5ft 11 in Valleys 26ft tin Ridges 61 ft bin Rakes 61 ft gin SEE Step Flashing Oft SEEM Transitions 25ft 1 in 10. N N 29 45 W 0001 Hips 54ft bin Wall Flashing Oft :r Unspecified Oft Note: The above diagram contains measurements that have been rounded up. 6 and 9 are written •6 and ag to avoid confusion. Some edge length totals have been hidden from the diagram to avoid overcrowding. Flashings are depicted as dotted lines. This report was prepared by Ian Robles. Copyright �K) 2021 Roofr.com i All rights reserved. 3 ® LUCIE Section D (Steep Slope Roof System) Roof System Manufacturer: GAF -ELK Notice of Acceptance Number: 10124-R29 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1: Zone 2e: Zone 2n: —Zone 2r:_____ Zone 3e: Zone 3r: Deck Type: PLYWOOD Type Undedayment: PEEL & STICK Roof Slope: 5 12 Insulation: N/A Fire Barrier: N/A Ridge Ventilation? Fastener Type & Spacing: 1 1/4" COIL NAILS 6" O.C. Yes Adhesive Type: r ROOF CEMENT Type Cap Sheet N/A Mean Roof Height: 15 Roof Covering: SHINGLES Type & Size Drip 6- Edge: