® MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) 11805 SW 26 Street,Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami,Florida 33175-2474
T(786)315-2590 F(786)315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economv
Polyglass USA Inc.
1111 W.Newport Center Drive
Deerfield Beach,FL 33442
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The
documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be
used in Miami-Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ).
This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product Control Section
(in Miami-Dade County)and/or the AHJ(in areas other than Miami-Dade County)reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner,the manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify,or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein,and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo,city, state and following
statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials,use,and/or manufacture of the product or process.Misuse of this NOA as an endorsement of any product,
for sales,advertising or any other purposes shall automatically terminate this NOA.Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed,then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA No.15-0410.04 and consists of pages 1 through 8.
The submitted documentation was reviewed by Freddy Seminol
NOA No.: 17-0614.22
rnAwtNoAwE couNrr Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 1 of 8
i
ROOFING COMPONENT APPROVAL
Cate¢ory Roofing
Sub-Catesory: Underlayment
Material: SBS,APP Self-Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Test Product
Product Dimensions Specification Description
Polystick IR-Xe 65'x 3'33/8" ASTM D 1970 A fine granular/sand top surface self-adhering,APP
Manufacturing Or 65'x 3' polymer modified,fiberglass reinforced,bituminous
Location#1  60 mils thick sheet material for use as an underlayment in sloped roof
assemblies. Designed as an ice&rain shield.
Polystick Dual Pro 61'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane. Designed as a
Location#2 metal roofing and roof tile underlayment.
Polystick Tile Pro 61'x 313/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
Manufacturing 60 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal
Location#2 roofing and roof tile underlayment.
Polystick TU Max 65'8" x 3'3-3/8" TAS 103 and A rubberized asphalt self-adhering,polyester reinforced
Manufacturing 60 mils thick ASTM D 1970 waterproofing membrane. Designed as a a roof tile Location#1  underlayment.
Polystick TU P 32'10"x 3'33/s" TAS 103 and A rubberized asphalt waterproofing membrane, glass-
Manufacturing 130 mils thick ASTM D 1970 fiber/polyester reinforced,with a granular surface
Location#2 designed for use as a tile roof underlayment.
Polystick TU Plus 65'x 3'33/8" TAS 103 and A rubberized asphalt self-adhering,glass-fiber/polyester
(Surface Printing) 80 mils thick ASTM D 1970 reinforced waterproofing membrane.Designed as a metal
Manufacturing roofing and roof tile underlayment.
Location#1 
Polystick MTS 65'8" x 3133/8" TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile,slate tiles and shingle underlayment.
Polystick MTS Plus 6518"x 3133/8' TAS 103 A homogeneous,rubberized asphalt waterproofing
Manufacturing 60 mils thick membrane,glass fiber reinforced with polyolefinic film
Location#2 on the upper surface for use as an underlayment for metal
roofing,roof tile,slate tiles and shingle underlayment.
Elastoflex S6 G 32'10" x 3'3 3/s" TAS 103 and Polyester reinforced, SBS modified bitumen membrane
Manufacturing ASTM D 6164 with a sanded back face and a granule top surface. For
Location#2 use in roof tile underlayment systems.
NOA No.: 17-0614.22
MIAWDADE COUNTY
Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 2 of 8
i
MANUFACTURING PLANTS:
1. Hazelton,PA
2. Winter Haven,FL
EVIDENCE SUBMITTED
Test Agency Test Identifier Test Name/Report Date
Trinity ERD P10870.09.08-R1 TAS 103 12/04/08
P10870.04.09 TAS 103/ASTM D4798&G155 04/13/09
P33360.06.10 ASTM D1970 07/01/10
P33370.03.11 TAS 103 03/02/11
P33370.04.11 ASTM D 1623 04/26/11
P36900.09.11 TAS 103/ASTM D4798&G155 09/01/11
P37300.10.11 TAS 110/ASTM D4798&D1970 10/19/11
P40390.08.12-2 ASTM D 1623 08/07/12
P37590.07.13-1 ASTM D6164 07/02/13
P45270.05.14 TAS 103,TAS 110&ASTM D1623 05/12/14
P46520.10.14 ASTM D1623 10/03/14
P44360.10.14 TAS 103 &TAS 110 10/07/14
P43290.10.14 ASTM D 1970&TAS 110 10/17/14
PLYG-SC10130.06.16-3 TAS 103 &TAS 110 06/27/16
PLYG-10130.06.16-1 ASTM D1970&TAS 110 06/27/16
PRI Asphalt Technologies PUSA-035-02-01 TAS 103 09/29/06
PUSA-055-02-02 TAS 103 12/10/07
PUSA-089-02-01 TAS 103/ASTM D4798&G155 07/06/09
Momentum Technologies,Inc. JX20117A TAS 103/ASTM D4798&G155 04/01/08
RX14E8A TAS 103/ASTM D4798&G155 11/09/09
DX23138B TAS 103/ASTM D4798&G155 02/18/10
DX23138A TAS 103/ASTM D4798&G155 02/18/10
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city
and state of manufacturing facility and the following statement: "Miami-Dade County Product Control Approved"
or the Miami-Dade County Product Control Seal as shown below.
MIAWDADE COUNTY
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1.This Notice of Acceptance.
2.Any other documents required by the Building Official or applicable building code in order to properly evaluate the
installation of this materials.
NOA No.: 17-0614.22
MIA MPDADE COUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 3 of 8
c
INSTALLATION PROCEDURES:
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(1): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c. at a minimum 4"head lap.(for
base sheet only)
Membrane: Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick
TU P,Polystick TU Plus,Polystick MTS or Polystick MTS Plus, self-adhered.
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(2): Anchor sheet mechanically fastened to deck,membrane adhered
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c.at a minimum 4" head lap. (for
base sheet only)
Membrane: Elastoflex S6 G,hot asphalt applied
Surfacing: See General Limitations Below.
Deck Type 1: Wood,non-insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E(3): Base sheet mechanically fastened to deck, subsequent cap membrane self-adhered.
Anchor/Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626.
Fastening: Per FBC 1518.2& 1518.4 Nails and tin caps 12" grid,6" o.c. at a minimum 4"head lap. (for
base sheet only)
Ply Sheet: Polystick MTS Plus, self-adhered with minimum 3" horizontal laps and minimum 6"
vertical laps.
Membrane: Polystick TU Plus,self-adhered.
Surfacing: See General Limitations Below.
MIAMFDADE COUNTY NOA No.: 17-0614.22
.,. Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 4 of 8
INSTALLATION REQUIREMENTS:
1. All nails in the deck shall be carefully checked for protruding heads. Re-fasten any loose deck panels,and
sweep the deck thoroughly to re move any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave,rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied. All side laps shall be a minimum of 3"and end laps shall
be a minimum of 6". Roll the membrane into place after removing the release strip. Vertical strapping of the
roof with Polystick is acceptable. Membrane shall be back nailed in accordance with applicable building code.
4. When applying the membrane in the valley,start at the low point and work to the high point,rolling the
membrane from the center outward in both directions.
5. For ridge applications,center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface,giving special attention
to lap areas.
7. Flash vent pipes, stacks,chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick Dual Pro,Polystick Tile Pro,Polystick TU Plus,Polystick MTS and Polystick MTS Plus may be
used in asphaltic shingles,wood shakes and shingles,non-structural metal roofing,roof tile systems and quarry
slate roof assemblies.
Polystick TU P may be used in all the previous assemblies listed except metal roofing.
Polystick IR-Xe may be used in all the previous assemblies listed except metal roofing and roof tile systems.
Polystick TU Max may be used in non-structural metal roofing and roof tile systems.
Elastoflez S6 G may be used in roof tile systems only.
3. Deck requirements shall be in compliance with applicable building code.
4. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall be applied to a smooth,clean and dry surface. The deck
shall be free of irregularities.
5. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be adhered directly over a pre-existing roof membrane
as a recover system.
6. Polystick IR-Xe,Polystick Dual Pro,Polystick Tile Pro,Polystick TU Max,Polystick TU P,Polystick TU
Plus,Polystick MTS and Polystick MTS Plus shall not be left exposed as a temporary roof for longer than the
amount of days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times;not to exceed the preceeding maximum time limitations.
Ex sure Limitations(Days)
MTS IR-Xe Elastoflex TU TU P Tile Pro Dual Pro TU Max MTS Plus
S6 G Plus
Winter Haven,FL 180 90 180 180 180 180 180 180 180
Hazelton,PA N/A 90 N/A 180 N/A N/A N/A 180 N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
NOA No.: 17-0614.22
MIAMI•DAD,COUNTY Expiration Date: 09/13/21
Approval Date: 07/06/17
Page 5 of 8
Rule 61 G20-3 of the Florida Administrative Code.
8. In roof tile application,data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance.
Polystick Tile Pro,Polystick TU Max,Polystick TU Plus or Elastoflez S6 G may be used in both adhesive
set and mechanically fastened roof tile applications.
Polystick Dual Pro is limited to mechanically fastened roof tile applications.
Polystick MTS and Polystick MTS Plus are limited to mechanically fastened with the limitations outlined in
Section 9.
Polystick TU P may be used in mechanically fastened roof tile applications with the exception of mortar set tile
applications.
9. When loading roof tiles on roof tile underlayment for(direct-to-deck)tile assemblies,the maximum roof slope
shall be as follows:(See Table Below)
Tile Polystick Elastoflex Polystick TU Plus, Polystick Polystick System (E3)
Profile MTS S6 G TU P,Tile Pro, TU Max MTS Plus MTS Plus with
Dual Pro TU Plus
Flat Tile Prohibited 4:12 6:12 6:12 5:12 6:12
without battens
Profiled Prohibited 4:12 6:12 6:12 4:12 6:12
Tile without battens
The above slope limitations can be exceeded only by using battens in accordance with the Approved Tile System
Notice of Acceptance and applicable Florida Building Code requirements. When battens are required,they shall
be utilized during loading and installation of tiles.
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure—two tiles
laid perpendicular to slope followed by a maximum four tile stack parallel to the slope,for a total of 6 tiles—for
all underlayments except Polystick MTS which shall be loaded onto battens.
(6 Max.Per Stack)
12