Loading...
HomeMy WebLinkAboutProduct Review AffidavitPlanning & Development Services. Department Building & Regulations Division Prod ct Review Affidavit fl # or Miami -Dade FLORIDA PRODUCT REVISION EXPIRATION Product Model # Manufacturer Glass Description Method of Attachment Building Design Product Design APPROVAL REVISION DATE Pressure Pressure For anchoring through frame into wood framing or 2x buck use #10 wood screws with sufficieni length to achive a 11/4" minimum embed. Into substrate. Locate anchors as FL17499.2 R8 10 /08/2023 SH Window 185 SH MI Window and Non Impact p shown in elevations and installation details.For anchoring through frame into masonry (+38) / (-48) (+50) / (-50) Doors / concret use 3/16" tapcons with sufficient length to achive a 11/4" minimum embed. I to substrate. Locate anchors as shown in elevations and installation details. For anch ring through frame into wood framing or 2x buck use #10 wood screws with sufficient; length to achive a 13/8" minimum embed. Locate anchors as shown in installation details.For anchoring through frame into masonry/ concrete use 1/4" MI Window and ELCO ult acontapcons with sufficient length to achive a 11/4" minimum embed. wJ FL15353.2 RS 12/31/2024 Vertical Mullion 5764 Doors Non Impact 1" min. edge distance. Locate anchors as shown in installation details. (+38) / (-48) (+48.1 / (-48.1) For anch ring through frame into wood framing or 2x buck use 410 wood screws with sufficien length to achive a 11/4" minimum embed. into substrate. Locate anchors as shown in elevations and installation details.For anchoring through frame into masonry MI Window and / concret use 3/16" tapcons with sufficient length to achive a 11/4" minimum FL15349.1 R14 4/3/2023 Fixed Window 185 PW Doors Non Impact embed. Vito substrate w min 2 1 2" edge distance. Locate anchors as shown in I / / g (+38) / (-48) (+60 / (-60 ) ) installation details. For anch ring through frame into wood framing or 2x buck use #10 wood screws with sufficient' length to achive a 13/8" minimum embed. Into substrate. Locate anchors as shown inlllelevations and installation details.For anchoring through frame into masonry MI Window and / $ use /16' tapcons with sufficient length to achive a 1 1 4" minimum concrete 3 p g / FL15332.2 R6 12/31{2024 Sliding Glass Door Series 420 Aluminum SGD Doors Non Impact embed. Into substrate w/ min 2 1/2" edge distance. Locate anchors as shown in (+33) / (-41) (+48.2) / (-48.2) installation details. 1/4' concrete screw 6" edge distance @head, 4" edge distance @ jamb, 4" each glde Opaque single of transom centerline to bucking. Fastener spacing 15" o/c max. @ head and jamb, FL20461.17 R6 12/31/2021 door with transom Smooth Star Therma-Tru N/A Min, emedment of all anchors to be 11/4" (+36) / (47) (+47) / (-47) FL16107.3 R13 R14 ( } DoubDGarage 16.2x7 73 W6 Clo a p y N/A / 3/$ x 2- {4" Hilti sleeve anchors 6"from ends 22" O/C +29 ( ) / (35) (+36) / (42) PENDING APPROVAL 3/8" Simpson Titen heavy duty screw anchor with 1 1/8" Op washer into grout filled CMU with min. emben of 2 3/4", min. edge distance of 4" and min. end distance of 4". Double Garage Max fastener spacing of 20". 3/8" dia. X 3" long lag screws with 1" OD washers with a _ FL8248.11 R20 12/31/2023_ Door (ALT) 8024 Wayne Dalton N/A - ` 19/32" thread penetration into seasoned dry wood supporting structure. +29 ( ) / ( -35 } (+34.4 ) / (38.3) tr ' 12/31/2023 Double Garage Series 170-175 177 180- 3/8" Simpson Titen heavy duty screw anchor with 2 3/4" embed min 6" between jamb FL14170.7 R14 (R15) (PENDING APPROVAL) Door (ALT) 185, 187 Overhead N/A and bracket location. 2 3/4" min edge distance. + 29 35 ( ) { ( ) + 34.4 38 3 ( ) / ( - ) Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" dia. heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per shingle placed 6-1/8" above the butt edge, approx. 1" and 13". from each end and 1/2" FL30310.1 R1 12/31/2024 Roof IKO SHINGLES IKO Cambridge N/A above each cutout. Drive nails straight so that nail head is flush with, but not cutting N/A N/A into shingle surface, I Miami -Dade approved corrosion risistant tin caps and 12 ga. 1-1/4" annular ring shank nails spaced 6"O.C. at all laps and three staggard rows fastened 12" O.C. in the field. FL15216.1 R8 12/31/2023 Underlayment RhinoRoof U20 Interwrap N/A FL5259.1 R32 12/23/2023 Underlayment PolysticklRXE Polyglass USA N/A Self adhesive (Alternate) FL17322.1 R7 12/31/2024 Underlayment Weatherivaster100 Atlas Roofing Corp N/A Self adhesive (Alternate) i FL34546.1 Rl 12/31{2024 .Underlayment Shield Granulated Owens Corning N/A Self adhesive (Alternate) FL27076.16 Rl 3/2$/2023 Underlayment Weather Armor 56 1 APOC N/A Self adhesive (Alternate) '. FL3792.5 R14 8/16/2021 Off Ridge Vent 770D Lomanaco N/A install per manufacturers recommended requirements. N/A N/A FL19567.2 R2 9/21/2026 Off Ridge Vent MMI MILLINUM METALS N/A Install per manufacturers recommended requirements. N/A N/A (ALTERNATE) FL33919.1 R1 12/31/2024 Soffit Variform Soffits PI Gem V(+31.6) N/A Install per manufacturers recommended requirements. / (-38.8) (+157) / (-46.1) 12/31/2023, Install per manufacturers recommended requirements. FL15272.1 R4 (R5) (APPROVAL PENDING) Soffit (Alt) T2 Alside N/A 1(+31.6) / (-38.8) (+75) / (-75) 1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 1 3/4" in FL16293.1 R3 12/31/2021 Hurricane Panels 24 GAGE Hurricane Storm N/A concrete {masonry, 2 1/2 `min. edge distance, 12' o/c max. spacing. Can be headed N/A (+47) / (-53) Less than 6' span panel MFG. screw or all thread but with wing nuts. 1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 1 3/4" in FL16293.1 R3 12/31/2021 Hurricane Panels 24 GAGE Hurricane Storm N/A concrete / masonry, 2 1/2" min. edge distance, 12" o/c max. spacing. Can be headed N/A (+45) / (-50) 6' span or more panel MFG. screw or all thread but with wing nuts. FL17147.1 R5 6/27/2021 Zip System Wall Sheathing Huber N/A Install per manufacturers recommended requirements. N/A N/A Sheathing James Hardie Install per manufacturers recommended requirements. FL13192.2 R6 12/31/2023 Lap Siding Cemplank Building Products, N/A Inc F41$92.1 R7 1/1/2055 I Joists (2 Story BCI ESR-1336 N/A Install per manufacturers recommended requirements. Only) CONTROL DATE 330.21 2194 HWYAIA, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdeslgngroup.com AA #: 0003325 W W V W � 0 h 0 q U Q � 0 CF SUSDIV. 7LOT: ST LUCIE COUNTY MASTER PA PROJECT* IG ODEL•EXPRESS SHINGLE ARAGE SWING: PAGE: 160 MPH EXP. C F -RIDA1SON5 PRINT DATE: 03.30.2[ PL A I 1 SCALE: 1 /4" =1' - 0 SKEET