HomeMy WebLinkAboutProduct Review AffidavitPlanning & Development Services. Department
Building & Regulations Division
Prod ct Review Affidavit
fl # or Miami -Dade
FLORIDA PRODUCT
REVISION EXPIRATION
Product
Model #
Manufacturer
Glass Description
Method of Attachment
Building Design
Product Design
APPROVAL REVISION
DATE
Pressure
Pressure
For anchoring
through frame into wood framing or 2x buck use #10 wood screws with
sufficieni
length to achive a 11/4" minimum embed. Into substrate. Locate anchors as
FL17499.2
R8
10 /08/2023
SH Window
185 SH
MI Window and
Non Impact
p
shown in
elevations and installation details.For anchoring through frame into masonry
(+38) / (-48)
(+50) / (-50)
Doors
/ concret
use 3/16" tapcons with sufficient length to achive a 11/4" minimum
embed. I
to substrate. Locate anchors as shown in elevations and installation details.
For anch ring through frame into wood framing or 2x buck use #10 wood screws with
sufficient; length to achive a 13/8" minimum embed. Locate anchors as shown in
installation details.For anchoring through frame into masonry/ concrete use 1/4"
MI Window and
ELCO ult acontapcons with sufficient length to achive a 11/4" minimum embed. wJ
FL15353.2
RS
12/31/2024
Vertical Mullion
5764
Doors
Non Impact
1" min. edge distance. Locate anchors as shown in installation details.
(+38) / (-48)
(+48.1 / (-48.1)
For anch
ring through frame into wood framing or 2x buck use 410 wood screws with
sufficien
length to achive a 11/4" minimum embed. into substrate. Locate anchors as
shown in
elevations and installation details.For anchoring through frame into masonry
MI Window and
/ concret
use 3/16" tapcons with sufficient length to achive a 11/4" minimum
FL15349.1
R14
4/3/2023
Fixed Window
185 PW
Doors
Non Impact
embed. Vito
substrate w min 2 1 2" edge distance. Locate anchors as shown in
I / / g
(+38) / (-48)
(+60 / (-60
) )
installation
details.
For anch ring through frame into wood framing or 2x buck use #10 wood screws with
sufficient' length to achive a 13/8" minimum embed. Into substrate. Locate anchors as
shown inlllelevations and installation details.For anchoring through frame into masonry
MI Window and
/ $ use /16' tapcons with sufficient length to achive a 1 1 4" minimum
concrete 3 p g /
FL15332.2
R6
12/31{2024
Sliding Glass Door
Series 420 Aluminum SGD
Doors
Non Impact
embed. Into substrate w/ min 2 1/2" edge distance. Locate anchors as shown in
(+33) / (-41)
(+48.2) / (-48.2)
installation details.
1/4' concrete screw 6" edge distance @head, 4" edge distance @ jamb, 4" each glde
Opaque single
of transom centerline to bucking. Fastener spacing 15" o/c max. @ head and jamb,
FL20461.17
R6
12/31/2021
door with transom
Smooth Star
Therma-Tru
N/A
Min, emedment of all anchors to be 11/4"
(+36) / (47)
(+47) / (-47)
FL16107.3
R13 R14
( }
DoubDGarage
16.2x7 73 W6
Clo a
p y
N/A
/
3/$ x 2- {4" Hilti sleeve anchors 6"from ends 22" O/C
+29
( ) / (35)
(+36) / (42)
PENDING APPROVAL
3/8" Simpson Titen heavy duty screw anchor with 1 1/8" Op washer into grout filled
CMU with min. emben of 2 3/4", min. edge distance of 4" and min. end distance of 4".
Double Garage
Max fastener spacing of 20". 3/8" dia. X 3" long lag screws with 1" OD washers with a
_
FL8248.11
R20
12/31/2023_
Door (ALT)
8024
Wayne Dalton
N/A
- `
19/32" thread penetration into seasoned dry wood supporting structure.
+29
( ) / ( -35 }
(+34.4 ) / (38.3)
tr
'
12/31/2023
Double Garage
Series 170-175 177 180-
3/8" Simpson Titen heavy duty screw anchor with 2 3/4" embed min 6" between jamb
FL14170.7
R14 (R15)
(PENDING APPROVAL)
Door (ALT)
185, 187
Overhead
N/A
and bracket location. 2 3/4" min edge distance.
+ 29 35
( ) { ( )
+ 34.4 38 3
( ) / ( - )
Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" dia.
heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per
shingle placed 6-1/8" above the butt edge, approx. 1" and 13". from each end and 1/2"
FL30310.1
R1
12/31/2024
Roof
IKO SHINGLES
IKO Cambridge
N/A
above each cutout. Drive nails straight so that nail head is flush with, but not cutting
N/A
N/A
into shingle surface,
I
Miami -Dade approved corrosion risistant tin caps and 12 ga. 1-1/4" annular ring
shank nails spaced 6"O.C. at all laps and three staggard rows fastened 12" O.C. in the
field.
FL15216.1
R8
12/31/2023
Underlayment
RhinoRoof U20
Interwrap
N/A
FL5259.1
R32
12/23/2023
Underlayment
PolysticklRXE
Polyglass USA
N/A
Self adhesive
(Alternate)
FL17322.1
R7
12/31/2024
Underlayment
Weatherivaster100
Atlas Roofing Corp
N/A
Self adhesive
(Alternate)
i
FL34546.1
Rl
12/31{2024
.Underlayment
Shield Granulated
Owens Corning
N/A
Self adhesive
(Alternate)
FL27076.16
Rl
3/2$/2023
Underlayment
Weather Armor 56 1
APOC
N/A
Self adhesive
(Alternate)
'.
FL3792.5
R14
8/16/2021
Off Ridge Vent
770D
Lomanaco
N/A
install per manufacturers recommended requirements.
N/A
N/A
FL19567.2
R2
9/21/2026
Off Ridge Vent
MMI
MILLINUM METALS
N/A
Install per manufacturers recommended requirements.
N/A
N/A
(ALTERNATE)
FL33919.1
R1
12/31/2024
Soffit
Variform Soffits
PI Gem
V(+31.6)
N/A
Install per manufacturers recommended requirements.
/ (-38.8)
(+157) / (-46.1)
12/31/2023,
Install per manufacturers recommended requirements.
FL15272.1
R4 (R5)
(APPROVAL PENDING)
Soffit (Alt)
T2
Alside
N/A
1(+31.6)
/ (-38.8)
(+75) / (-75)
1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 1 3/4" in
FL16293.1
R3
12/31/2021
Hurricane Panels
24 GAGE
Hurricane Storm
N/A
concrete {masonry, 2 1/2 `min. edge distance, 12' o/c max. spacing. Can be headed
N/A
(+47) / (-53)
Less than 6' span
panel MFG.
screw or all thread but with wing nuts.
1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 1 3/4" in
FL16293.1
R3
12/31/2021
Hurricane Panels
24 GAGE
Hurricane Storm
N/A
concrete / masonry, 2 1/2" min. edge distance, 12" o/c max. spacing. Can be headed
N/A
(+45) / (-50)
6' span or more
panel MFG.
screw or all thread but with wing nuts.
FL17147.1
R5
6/27/2021
Zip System
Wall Sheathing
Huber
N/A
Install per manufacturers recommended requirements.
N/A
N/A
Sheathing
James Hardie
Install per manufacturers recommended requirements.
FL13192.2
R6
12/31/2023
Lap Siding
Cemplank
Building Products,
N/A
Inc
F41$92.1
R7
1/1/2055
I Joists (2 Story
BCI
ESR-1336
N/A
Install per manufacturers recommended requirements.
Only)
CONTROL
DATE 330.21
2194 HWYAIA, SUITE 301
INDIAN HARBOUR BEACH,
FLORIDA 32937
PH: 321-802-3591
www.abdeslgngroup.com
AA #: 0003325
W
W
V
W
�
0
h
0
q
U
Q
�
0
CF
SUSDIV. 7LOT:
ST LUCIE
COUNTY
MASTER PA
PROJECT*
IG
ODEL•EXPRESS
SHINGLE
ARAGE SWING:
PAGE:
160 MPH EXP. C
F
-RIDA1SON5
PRINT
DATE: 03.30.2[ PL A I 1
SCALE: 1 /4" =1' - 0
SKEET