Loading...
HomeMy WebLinkAboutblower door & duct leakageDuct Leakage Test Report Prescriptive or Performance Method Permit # Job Information Builder: DRHORTON Community: Lot:gb Address: T-r,. 1 Unit: City: State: FL Zip: Duct Leakage Test Results 0 Presciptive Method 0 Performance Method System 1 cfm25 O Prescriptive Method cfm25 (total) System 2 To qualify as "substantially leak free" Qn must be less than or equal to 0.04 cfm25 if air handler unit is installed. If air handler unit is not installed, Qn Total System 3 must be less than or equal to 0.03. This testing method meets the cfm25 requirements in accordance with Section R403.2.2 Sum of any additional Total of all systems U Performance Method cfm25 (Out or Total) cfm25 To qualify as "substantially leak free" Qn must not be greater than the /�'a = � 4n proposed duct leakage On specified on Form R405-2014 4 7 _ Total of all systems Total Conditioned Leakage Type selected Qn specified on Form Square Footage on Form R405-2014 R405-2024(Energy Calc) PASS � FAIL (EnergyLalc) C� Testing Company Company Name: SUN SEAL LLC Phone: 321-412-0035 1 hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected compliance path as stated above, either the Prescriptive Method or Performance Method. Date of Test: V ice( Signature of Tester: .1AZ in J Printed Name of Tester: RAULY BAGGETT License/Certification # 5066185 Issuing Authority BPI Envelope Leakage Test Report (Blower Door Test) R402.4.1.2 Compliance Permit # Job Information Builder: DR HORTON Community: Lot: Po Address: 33 Tr' 'f Cr Unit: Cq,' City: 0- ;E, State: FL Zip: Air Leakage Test Results Passing results must be 7 ACH(SO) or less /J0`7 x 60 = 15-7d U = �_ Method for calculating building volume: CFM(50) Building Volume ACH(50) O Retrieved from architectural plans O Code software calculated F-��-Ass �FAIL O Field measured and calculated � tl When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department. Certification of Test Results R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of Testing Company ompany Name: SUN SEAL LLC Phone, 321-412-0035 hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected path as stated above, either the Prescriptive Method or Performance Method. Date of Test: 2 1 1, t : 0 3- Signature of Tester: lti Printed Name of Tester: RAU Y BAGGETT License/Certification # 5066185 Issuing Authority BPI