HomeMy WebLinkAboutBuilding Plansk aR„ rS 2 Fax- STATE OF FLORIDA DESIGN CRITERIA: CERTIFIED BUILDING CONTRACTOR: -nORIDA EUUING CODE, RESIDENTIAL, 7TH EDITION (2020) -ALL LOCAL AND STATE CODES DR HORTON HOMES -OCCUPANCY —RESIDENTIAL, GROUP R3 1430 'CULVER DRIVENE -CONSTRUCTION TYPE -MIN. INTERIOR FINISH — VB — CLASS B PALM BAY FL 32907 -BASIC WIND SPEED — Vult=160 MPH I Vasd=124 MPH TEL: (321) 733-7092 -EXPOSURE _ C FAX: (321) 733-7972 -I-STORY RESIDENCE -2—STORY'RESDENCE — MAX. HEIGHT AS PER LOCAL AND STATE CODES STATE OF FLORIDA PROFESSIONAL ARCHITECT: MICHAEL C. ANDERSON AR No. 17305 A.B. DESIGN GROUP, LLC' 2194 HWY AIA, SUITE 301 INDIAN HARBOUR BEACH, FL 32937 Tel: (321) 802-3591 DRAWING / CONTRACT DOCUMENT REVIEW BY BUILDER i THE BUILDER ASSUMES ALL LIABILITY FOR -NTERPRETATION OF THE CONTRACT DOCUMENTS. i :T' ANY ASPECT OF THE CONSTRUCTION (AS .DESCRIBED IN THIS DRAWING SET) ARE UNCLEAR AND SIN NEED OF FURTHER DETAILING OR EXPLANATION IN ORDER TO BUILD THIS PROJECT BASED ON THIS DRAWING SET, THE CORRECT PROCEDURE IS FOR THE BUILDER TO SUBMIT A WRITTEN R.F.I. (REQUEST FOR I INFORMATION) TO THE ARCHITECT OR ENGINEER FOR CLARIFICATION. AB DESIGN GROUP WILL RESPOND TO ALL WRITTEN BFI's IN yYRITTEN/DRAWN FORMS IN A TIMELY MANNER. AB DESIGN GROUP TAKES NO RESPONSIBILITY FOR INTERPRETATIONS OF CONSTRUCTION BY THE BUILDER WHEN NO RFI's HAVE BEEN GENERATED FOR UNCLEAR ASPECTS OF THE ^ONSTRUCTION BASED ON THE DRAWING SET. SQ.F T. CALC.'S LIVING Mir, 80. FT. GARAGE 430 SQ. FT. ENTRY Iro SQ. FT. LANAI 80 SQ. FT. TOTAL 2442 SQ. FT. A/C VOLUME 164ii 6 GU. FT. ABBREVIATIONS REVISIONS _ ABV. ABOVE LAV. LAVATORY DATE DESCRIPTION 01/26/18 A/C AIR CONDITIONING LUM.. LUMINOUS CD'S ISSUED ADJ. ADJUSTABLE M.C. MEDICINE CABINET 0145/18 -- -- 20111 % UPDATE ALL ALTERNATE MFR... MANUFACTURER AMP.. BD.. AMPERAGE BOARD MIN M.T. MINIMUM METAL THRESHOLD 01/16n8 CD'S REISSUED CL CAB. CENTER LINE CABINET MTD. MTL. MOUNTED METAL 02/2148 SIDING ELEVATIONS ADDED - CLG. CLR. CEILING CLEAR N.T.S. O.C. NOT TO SCALE ON CENTER 03rz6n8 Cp�$RE-1SSUED 04/I9/IS FOOTING VISION PER M. BOWES CONC. CPT. CONCRETE TE CARPET PL P.B. PROPERTY LINE PUSH BUTTON 06/21n8 - CD'S � ISSUED CERAMIC TILE PH. PHONE C.T. CER D. DRYER PLT. PLATE DBL. DOUBLE PLYWD. PLYWOOD 02n9/19 ADDED CURELESS FOOTER AT GARAGE DETAIL (FORT MYERS) U.G. DIA. DUAI, GLAZED DIAMETER PR. P.T. PAIR PRESSURE TREATED 02/224S PLAN MAINTENANCE 03/28/I9 REVISED LINTEL SITE AT FRONT ENTRY DOOR DIM. DISP. DIMENSION DISPOSAL. R. RAD. RISER RADIUS 0412013 ADDED ADDITIONAL RECEPTACLE IN GARAGE PER WILL EATSON (MEL DP. DR.. DEEP DOOR R.A.G. REF. RETURN AIR GRILL REFRIGERATOR 04/24/19 REVISED HVAC VOLUMES ON SOFT GALC SCHEDULE (MELE.) D.S. DOWNSPOUT RM. ROOM DTL D.W. DETAIL DISHWASHER R.O. S.C. ROUGH OPENING SOLID CORE EXTDR 064249 ADDED 'EXTERIOR MONO DEEP FOOTER' DETAIL 12/51.IA (ORL) EA. ELEV. EACH ELEVATION S.D. S.H. SMOKE DETECTOR SINGLE HUNG 06/21n9 ADDED LED LIGHTS a KITCHEN E 6ATH PER MARK EOWES FQ. EXH. EQUAL EXHAUST SHT. SHTHG. SHEET SHEATHING 01n9n9 ADDED STONE. OPTION ELEVATION G t D (TAMPA) 09/11n9 ELEVATION Y3' SIDING -ADDED LOUVER • GAME ROOF EXT. F.G.IFX. EXTERIOR FIXED GLASS SH,VR. SIM. SHOWER SIMILAR 10/25/19 ADDED OPT. B'-0' CEILING HEIGHTS E.G. FUEL GAS SL SLIDING FIN. FLR. FINISH FLOOR SL GL. STD. SLIDING GLASS A'TANDARD 6/01/20 REPLACE USP CONNECTORS WITH SIMPSON CONNECTORS FLUOR. PR. DR. FLUORESCENT. FRENCH DOOR SWS SHEAR WALL SECTION 04i01/20 IM REVISE ENKAVENT RADON PLAN DIMENSIONS GA. GA. FOOTING GAUGE TEMP. THK. TEMPERED HICK F.D GLASS THICK 04/09n0 ..OPT. -0' CLG. HGT. ADDED LED LIGHT IN FOYER 8' �,/® OPT, 8�-0' CLG. HGT. ELEVATION 'G'- REVISED HEIGHT OF ARCHWAY .GAR. DISP. G.Fa. GARBAGE DISPOSAL GROUND -FAULT CIRCUIT T.O.C. T.O.P. TOP OF CURB TOP OF 05/06/20 ADDED ELEVATIONS V t 'M' (ORL) - 6L.' GYP. BD. INTERRUPTER GLASS GYPSUM BOARD ' T.O.S. TYP. U.N.O. TOP OF SLAB TYPICAL: UNLESS NOTED. 01/15/20 ADDED ELEVATIONS 'MG'-'MH'-'MS' (ORL) H.B. H.C.. HOSE BIB HOLLOW CORE V.P. OTHERWISE VAPOR PROOF 01/01/21 2020 FEC UPDATE HDR. HEADER W. WASHER HGT..OR HT HEIGHT W/ WITH INSUL. INSULATION WD. WOOD TNT. INTERIOR. WDW. WINDOW W/H WATER HEATER WIL WROUGHT IRON INDEX OF DRAWINGS i ' ARCHITECTURAL SHEET # DESCRIPTION PG Cl—COVER SHEET PG GN— GENERAL NOTES PG Al —FLOOR PLAN PG A2C-ELEVATION "C" PG El —ELECTRICAL PLAN PG Pl —PLUMBING PLAN PG M1—MECHANICAL PLAN PG D1—DETAILS PG D2—DETAILS PG WAI -WALL ASSEMBLY DETAILS PG WA2=WALL ASSEMBLY DETAILS PG WA3—WALL ASSEMBLY DETAILS PG WA4—NOT USED PG WA5=NOT USED PG WA6—WALL ASSEMBLY DETAILS STRUCTURAL SHEET # DESCRIPTION PG S1—FOUNDATION PLAN PG S 1.I A- D E TAILS Reviewed for code P G S 1.2 —DOWEL P LAN Compliance Universal f_rgineenng. PG S1.2A—DETAILS 3cences PG S2—LIFT BEAM PLAN AND NOTES PG S2.1A-DETAILS PG S2.2A—SAFE LOAD TABLES PG S3-FRAMING' PLAN PG S3.1A-DETAILS PG S3.113—DETAILS PG S3.1C—DETAILS PG SN1—DETAILS 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 a' 'jiamuv. CREEKSIDE PHASE 2 LOT #27 PROJECT# � 04321.200 027R1 MODEL• 4EBB "1828-CALI" GARAGE STnXG: RIGHT PAGE: COVER SHEET 160 M-L'H EXP. C uiE-aT STATE OF FLORIDA MAR 19` 2021 MICHAEL C. ANDER,f)[4 AFC NO 17,10 c I9ATE:E- 03/17/21 SCALE: 1/4"=1'—O" SHEET 1 C 1 GENERAL NOTES SITE WORK 1. ALL WORK DONE UNDER THIS CONTRACT SHALL BE IN COMPLIANCE WITH THE FLORIDA BUILDING CODE RESIDENT IAL (I$BCR) 1. REFER TO THE SOILS REPORT FOR SPECIFIC DESIGN REQUIREMENTS (IF REQUIRED BY BUILDING DEPARTMENT). 7th EDITION, (2020), ALL REFERENCED CHAPTERS, CODE SECTIONS AND TABLES STATED IN THESE DOCUMENTS ARE UNDIER 2. REFER TO THE CIVIL DRAWINGS FOR LOCATION OF BUILDING WORKING POINTS, ROUGH GRADING, ON -SITE UTILITIES, FBCR 7TH EDITION (2020) UNO. SITE IMPROVEMENTS, SITE RETAINING WALLS, AND SPECIFIC GENERAL NOTES, THE SOILS REPORT AND CIVIL 2. WHERE BUILDING LOCATIONS ARE DETERMINED TO BE IN WIND BORNE DEBRIS REGIONS, ALL EXTERIOR DRAWINGS SHALL OVERRIDE CONFLICTS WITH SITE WORK NOTED HEREIN.SEE LANDSCAPE DRAWINGS FOR FINAL BUILDING OPENINGS SUCH AS WINDOWS AND DOORS SHALL BE PROTECTED AGAINST WINDBORNE DEBRIS BY FINISH GRADES, PLANTING AND IRRIGATION, THE INSTALLATION OF STRUCTURAL PANELS OR IMPACT -RESISTANT GLASS. THESE OPENING PROTECTIONS SHALL BE DESIGNED AND INSTALLED IN ACCORDANCE WITH FBCR 2020 CHAPTER 3, SECTION R301.2.1.2. 3. ELEVATIONS SHOWN ON THE SITE DRAWINGS ARE MINIMUM REQUIRED DEPTHS, IF DIFFERENT CONTACT THE ARCHITECT, 3. DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR TOWORK PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND, 4. NO EXCAVATION SHALL BE MADE WHOSE DEPTH BELOW THE FOOTING IS GREATER THAN''/z THE HORIZONTAL DISTANCE FROM THE NEAREST EDGE OF THE FOOTING. 4. THE CONTRACTOR SHALL BRING ERRORS AND OMISSIONS WHICH MAY OCCUR IN CONTRACT DOCUMENTS TO THE ATTE TION OF THE ARCHITECT IN WRITING AND WRITTEN INSTRUCTIONS SHALL BE OBTAINED BEFORE PROCEEDING WITH THE WORK. 5. ALL BACKFILL AT STRUCTURES, SLABS STEPS, AND PAVEMENTS SHALL BE CLEAN GRANULAR FILL. PLACE IN 8" LAYERS THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY ERRORS DISCREPANCIES OR OMISSION IN THE AND COMPACT TO 95% MAXIMUM DRY DENSITY DETERMINED iN ACCORDANCE WITH ASTM D1557-2012 El. THE CONTRACT DOCUMENTS, OF WHICH THE CONTRACTOR FAILED TO NOTIFY THE ARCHITECT BEFORE CONSTRUCTIO AND IOR BUILDING SITE SHALL BE KEPT DRY SO THAT EROSION WILL NOT OCCUR IN THE FOUNDATIONS. FABRICATION OF THE WORK. 5. THE ARCHITECT/ENGINEER SHALL NOT BE RESPONSIBLE FOR THE SAFETY AND CONSTRUCTION PROCEDURES, TECHNIQUES, 6. COMPACTION BY FLOODING OR JETTING IS STRICTLY PROHIBITED. OR THE FAILURE OF THE BUILDER TO CARRY OUT THE WORK IN ACCORDANCE WITH THE DRAWINGS OR THE REQUIRED 7 DO NOT BACKFILL UNTIL SLABS HAVE CURED OR HAVE BEEN PROPERLY BRACED. (WHERE APPLICABLE) 6. THE STRUCTURAL DESIGN IS BASED ON THE INTERACTION OF ALL PARTS OF THE COMPLETED BUILDING. THE CON 1CODES. RAC I OR 8. EXCAVATIONS TO BE A MINIMUM OF 3' 0" BEYOND NEW FOOTING LINE. SHALL SOLELY BEAR THE RISK FOR PROVIDING ADEQUATE STABILITY AND SAFETY OF THE STRUCTURE DURING CONSTRUCTION UNTIL PERMANENT MEMBERS ARE COMPLETELY INSTALLED. 9. THE GENERAL CONTRACTOR MUST TAKE MEASURES TO CONTROL SOIL EROSION AS PER ALL LOCAL AND STATE 7. DETAILS SHOWN ON THE DRAWINGS ARE TO BE CONSIDERED TYPICAL FOR ALL SIMILAR CONDITIONS. REQUIREMENTS. 8. THE CONTRACTOR SHALL MAKE NO STRUCTURAL CHANGES WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT/ENGINEER. 10. CONTRACTOR IS TO VERIFY THE ELEVATION OF THE FINISHED FLOOR SLAB WITH THE SIGNED AND SEALED SURVEY WHICH COMPLIES WITH ALL LOCAL CODES HAVING JURISTICTION, INCLUDING ALL APPLICABLE STATE, CITY AND 9. NO STRUCTURAL MEMBERS ARE TO BE CUT FOR PIPES, DUCTS, ETC. UNLESS SPECIFICALLY DETAILED. COUNTY BUILDING AND ZONING CODES. GARAGES AND CARPORTS 11. SWIMMING POOL, DECK, SPA AND ASSOCIATED WORK IS TO BE PERMITTED SEPARATELY BY ENGINEERED SHOP 1. GARAGE DOOR DRAWING. A. ENGINEERED FOR MIN. WIND LOAD, LISTED ON COVER SHEET B. DETAIL TO BE SUPPLIED BY GARAGE DOOR SUPPLIER 12. TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES, C. DETAIL TORE ATTACHED TO PERMIT PACKAGE BY BUILDER BAITING SYSTEMS AND PESTICIDES APPLIED TO WOOD, OR OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED FOR USE AS A PREVENTATIVE TREATMENT' TO NEW CONSTRUCTION. UPON COMPLETION OF THE 2. AS PER SECTION R302.5.1: OPENINGS FROM A PRIVATE GARAGE DIRECTLY INTO A ROOM USED FOR SLEEPING APPLICATION OF THE TERMITE PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE PURPOSES SHALL NOT BE PERMITTED. OTHER, OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIP ED WITH BUILDING DEPARTMENT BY THE LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING STATEMENT: SOLID WOOD DOORS NOT LESS THAN 1 3/8 INCHES IN THICKNESS, SOLID OR HONEYCOMB CORE STEEL DOORS NOT THICK, OR 20 MINUTE FIRE DOORS LESS THAN "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. 1 3/8 INCHES -RATED TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY THE FLORIDA DEPARTMENT OF 3. AS PER SECTION R302.5.2: DUCTS IN THE GARAGE AND DUCTS PENETRATING THE WALLS OR CEILINGS SEPARATING THE 1 AGRICULTURE AND CONSUMER SERVICES." DWELLING FROM THE GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO.26 GAGE (0.48 MM) SHEET STEEL V MIN. RIGID ON -METALLIC CLASS OR CLASS 1 DUCT BOARD OR OTHER APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE: 4. AS PER SECTION R302.6 & TABLE R302.6: THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREAlBY NOT LESS THAN %-INCH GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE ', SEPARATED FROM ALL HABITABLE ROOMS ABIOVE BY NOT LESS THAN 5 / 8 -INCH TYPE X GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR -CEILING ASSEMBLY, THE STRUCTURE SUPPORTING THE SEPARATION SHALL A LSO BE PROTECTED BY NOT LESS THAN'/ -INCH GYPSUM BOARD OR EQUIVALENT. TIMBER 1. ALL WOODS AND WOOD CONSTRUCTION SHALL COMPLY WITH SPECIFICATIONS AND CODES MODIFICATIONS AS SPECIFIED HEREIN: A. AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (STANDARDS MANUAL) B. NATIONAL FOREST PRODUCTS ASSOCIATION. I. NATIONAL DESIGN SPECIFICATIONS (NDS) FOR WOOD CONSTRUCTION C. SOUTHERN PINE INSPECTION BUREAU: I. STANDARD GRADING RULES FOR SOUTHERN PINE LUMBER D. TRUSS PLATE INSTITUTE: I. NATIONAL DESIGN STANDARDS FOR LIGHT METAL PLATE CONNECTED WOOD TRUSSES (TPI 1-2014) E. APA - THE ENGINEERED WOOD ASSOCIATION: 1. ENGINEERED WOOD CONSTRUCTION GUIDE F. AMERICAN WOOD PRESERVERS ASSOCIATION STANDARDS 2. ALL LUMBER EXPOSED TO WEATHER, OR AGAINST SOIL, CONCRETE OR MASONRY MUST BE PRESSURE TREATED. 3. MINIMUM NAILING PER CHAPTER 6- WALL CONSTRUCTION AND TYPICAL NAILING SCHEDULE ON PLANS. 4. NOTCHING OR CUTTING OF FRAMING MEMBERS SHALL COMPLY WITH CHAPTER 6- WALL CONSTRUCTION. 5. WALL SHEATHING SHALL BE PER STRUCTURAL, SEE ROOF/WALL/FLOOR SHEATHING FASTENER SCHEDULE ON SHEET SN1. 6. MINIMUM DIMENSION OF ANY PLYWOOD SHEET SHALL BE 24" AND THE MINIMUM AREA SHALL BE 8 FT SO. PLUMBING 1. SANITARY LINES SHALL BE OF CAST IRON OR PVC (SCHEDULE 40) AS APPROVED BY THE BUILDING OFFICIAL. 2. WATER SUPPLY LINES SHALL BE CPVC OR UPONOR PEX "A" (CROSS -LINKED POLYETHYLENE) WITH F1960 FITTINGS. 3. CONDENSATION LINES SHALL BE MINIMUM%" PVC (SCHEDULE 40), INSULATED WITH %z AMAFLEX. 4. SHOWER HEADS SHALL HAVE A FLOW CONTROL DEVICE TO GIVE A MAXIMUM FLOW OF 3 GPM EACH, 5. ALL CLEANOUTS SHALL BE FLUSH WITH GRADE. 6. NO VENT STACKS SHALL PASS THROUGH ROOF CRICKETS, VALLEYS, OR RIDGES. 7. SIZE AND LOCATION OF CLEANOUTS SHALL CONFORM TO FBCR SECTION P3005.2 8. FIXTURE SUPPLY SIZES SHALL CONFORM TO FBCR SECTION P2903. 9. THE PLUMBER IS TO DIVERT ALL VENTS TO REAR ELEVATION WHEN POSSIBLE. 10. DRILLING & NOTCHING OF WOOD FRAMED STRUCTURAL MEMBERS SHALL FOLLOW PROVISIONS OF FBCR SECTIONP2603.2 EXTERIOR WALL COVERINGS 1. ALL EXTERIOR WALL COVERINGS AND SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED FOR THE WALLS FOR COMPONENTS AND CLADDING LOADS 1N ACCORDANCE WITH FBCR TABLE R301.2(2) AS MODIFIED BY FBCR TABLE R301.2(3), MANUFACTURED SOFFITS SHALL BE TESTED AT1.5 TIMES THE DESIGN PRESSURE EXTERIOR FINISHES 1. WHEN PLASTERING WITH CEMENT, PLASTER SHALL NOT BE LESS THAN THREE COATS, %" THICK, OVER FRAMED WALLS APPLIED OVER PAPER BACKED METAL LATH OR WIRE FABRIC LATH AND WITH TWO LAYERS OF VAPOR BARRIER, NOT LESS THAN 2 COATS, 1/2" THICK, WHERE APPLIED OVER MASONRY OR CONCRETE. 2. STUCCO OR PORTLAND CEMENT PLASTER SHALL BE INSTALLED,PROPORTIONED AND MIXED IN ACCORDANCE WITH ASTM-C926-18b, ASTM-Cl063-19a & ASTM-Cl787. 3. LATH & ACCESORIES PER ASTM-C-1063-19a & R703.7.1. ALL STUCCO APPLICATION DETAILS, INCLUDING BUT NOT LIMITED TO: ALL STUCCO CONTROL JOINTS KICK -OUT DETAILS "L" FLASHING HORIZONTAL LATH AND PAPER DETAILS PIPE PENETRATION DETAILS VENT PENETRATION DETAILS WEEP SCREED DETAILS CONDUIT PENETRATION DETAILS CASING BEAD DETAILS DRIP EDGE DETAILS CANTILEVER DRIP EDGE DETAILS CORNER BEAD DETAILS WINDOW CASING DETAILS STUCCO TO SIDING TRANSITION DETAILS WINDOW FLASHING DETAILS 4. SHALL BE INSTALLED PER ASTM-C1063 -19a AND R703.7, FIRE RESISTANT CONSTRUCTION UNDER STAIR PROTECTION: 1. ENCLOSED ACCESSIBLE SPACE UNDER STAIRS SHALL HAVE WALLS, UNDER STAIR SURFACE AND ANY SOFFITS PROTECTED ON THE ENCLOSED SIDE WITH 1/2" GYPSUM BOARD. R302.7. EXTERIOR CEILINGS 1. EXTERIOR CEILING TO BE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD INSTALLED PERPENDICULAR TO THE FRAMING MEMBERS. THE 1/2" GOLD BOND BRAND EXTERIOR SOFFIT BOARD IS TO BE SECURED TO THE FRAMING MEMBERS WITH 1 1/4" TYPE "W" DRYWALL SCREWS AT 12" O.C. (PER MANUFACTURER'S SPECIFICATIONS), CONSTRUCTION OBSERVATION CONSTRUCTION OBSERVATION SERVICES / CONSTRUCTION ADMINISTRATION SERVICES ARE NOT A PART OF AS DESIGN GROUPS SERVICES FOR THIS PROJECT. IT IS UNDERSTOOD AND AGREED THAT AB DESIGN GROUP'S SCOPE OF SERVICES DOES NOT INCLUDE PROJECT OBSERVATION OR REVIEW OF THE BUILDER'S / CONTRACTOR'S PERFORMANCE OR ANY OTHER CONSTRUCTION PHASE SERVICES, AND THAT SUCH SERVICES WILL BE PROVIDED BY THE BUILDER. THE BUILDER ASSUMES ALL RESPONSIBILITY FOR INTERPRETATION OF THE CONTRACT DOCUMENTS, AND FOR CONSTRUCTION OBSERVATION. Reviewed for cod,IQ Universal Engineer,nu Sciences CONTROL DATE: 12/10/20 (RM) 2194 H WY AIA, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 "SGGI r. ac rrOT: CREEKSIDE PHASE 2 LOT #27 PROJECIT# 04321.1'00 02'(R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: Y. , �I GENERAL NOTES 160 MPH E w . F OF FLORIDA J - 7A13NO 2021 z MIIIN °aiatl DATE: / / 0317l 21 I DATE: SCALE: 1/4"=1' - 0" SHEET G�T JL V FLAME SPREAD AND SMOKE INDEX FOR WALL AND CEILING FINISHES SHALL BE IN ACCORDANCE WITH SECTION FBC R302.9.1 THROUGH FSC R302.9.4 FLAME SPREAD AND SMOKE-DEVEL011i INDEX FOR INSULATION SHALL BE IN ACCORDANCE WITH SECTION FBC R302.10.1 THROUGH FBC R302.105 20 all r , N —._ 10_m' —12_4l --_ I t I -I --------- I.I 21'-0' t COVERED j e0 LANAI I :o 8'-8' CL G (] I ® I (2) 3052-SH (2) 052-SH 6068 S.G.D. EGRESS LIVING c0 ROOM DINING W-V CL& r ROOM BEDROOM#1 B,-B, CLI N B 2X8 N 0 All - 01 II" 7 -5" 4'-4 O 6' 11'_10" 4 _ 81_0 V. ZA N ------ — — — — — — — — —V. I 8' W W�I.C. CLI q a. a, cl� I — — — — — — — a� r co — — — --F` =� 36'x60" 9 I GIV. "- ---" SHWR. PAN - 1OPT i i i I �� W/ ENCL — 13'-0" 112'-8" b24 SINK IR-ISH -S KITCHEN AI LAUNDRY I _ I� IR-ISH -8 g'_g" CLI B 8 rxl o ,n _ 2�_4" � a L----" 6'_0 `� PAN. 36 RANGE b36 _ _ rr---TI — ,n AI � GLIS _� i I `8 _ _ _ 3-SH O V ARC i 0� ii I _ ti'----� BEDROOM #4 it --� DEN 1 ,� IIV a -a cL.r;. II111-03 >�U �� -m" ry 2'-8 t 3-6 4 4 -0" -I 8' LU (KIn N u lil BEgDR�OOM#3 3 3'-4" 6'-5" 3'-8" e 0 (� a I I F e ATTIC' R II I ATTIC LAV. B IIu L ACCESS J >10 BOLLARD OND AI IIQ n r N BATH #2 `8 I I I ep AS REQ. 8'-8' 0A I I PER BLDG. `� CODE GARAGE J ro - 2 _ z' V. 8 -8 GLCs N FOYER - BEDROOM #2 s'-e' clr'' 3068 W/ 8'-8' CLCs •� ,nl ry °� `gs 36'X12' 1IT. TRANS. F. 5 1/2" 1/2" 3'-5" asic 1§1(2) 3052-SH I m -- ARCH G16'-0"X1'-0'O.H.D. - - --- - -------------------- - Q 10'-2" 3'-10" 21_5 14'-0' 4'-4" 2"-4" 4i •_ lF p I E;�rABL.r-•.�.. ROOFS (f ?.:: 110' t i- ti•' i ( GABLE ROOFS 90. : 0 3W, FIGURE S301 2('P) COMPONENT AND CLADDING PRESSURE ZONES FLOOR PLAN SCALE: 1/4' = I'-O' NOTE: -2-8 LOUV. DOOR W/ AIR HANDLER ON METAL STAND OR 2-8 SOLID DOOR W/ RETURN PLENUM AND RETURN AIR GRILLE. - VERIFY CONDENSER PAD LOCATION WITH SITE PLAN. -OTHER OPENINGS BETWEEN THE GARAGE AND RESIDENCE SHALL BE EQUIPPED WITH SOLID WOOD DOORS NOT LESS THAN 1 3/5' (35 MM) IN THICKNESS, SOLID OR HONEYCOMB -GORE STEEL DOORS NOT LESS THAN 1 3/8' (35 MM) THICK OR 20-MINUTE FIRE -RATED DOORS. - EGRESS NOTE: DO NOT SHUTTER FRONT DOOR, FRONT ENTRY DOOR TO BE EGRESS POINT WHEN THE HOME IS SHUTTERED. - REFER TO BUCKING DETAILS FOR BUCKING AND RO NOTES. -FRAMED WALL SEPARATION BETWEEN THE UNCONDITIONED GARAGE AND CONDITIONED SPACED SHALL HAVE AN INSULATION R VALUE OF R-13. -CEILING R VALUE TO BE R-30 INSULATION ABOVE CONDITIONED SPACE. -FOR CONSISTENCY, THE VOLUME CALCULATIONS ON PLANS ARE PROVIDED BY THE HVAC CONTRACTOR AND ARE OF THEIR CLOSEST ALLOWABLE SOFTWARE TOLERANCES. -OPENING INFORMATION BELOW IS DIRECTLY FROM THE PLAN SET. U-VALUE AND SHCG ARE INFORMATION PROVIDED BY THE MANUFACTURER AS LISTED IN THE RESPECTIVE PRODUCT SPECIFICATIONS �M=m m�r Imp-, m� NOW��®0 EXTERIOR MASONRY WALL BRCS. HEIGHTS 10'-8° BRG. 11'-4' BRG. SQ.FT. CALC. S LIVING GARAGE ENTRY LANAI 1816 SQ. FT. 430 SQ. FT. 16 SQ. FT. SO SQ. FT. TOTAL 2442 SQ. FT. A/C VOLUME 16411.6 CU. FT. COWONENT AND CLADDING MILD LOADS BAW MILD EVOSUIf FOR 3 SECOND G= OPENNOS AND TYPE SOUNE FOOTAGE ZONE W WH WIND M FEMARKS MIN. WINDOW 10 5 34/-45 CRITERIA EXTERIOR SWING 18 5 33/-43 DR. MIN. CRITERIA S.G.D. MIN. 41 5 31/-39 CRITERIA 8010 O.H.D. 56 5 25.1/-313 12'xI2' SOFFIT 1 5 313/-411 BASIC WIND SPEED MPH = 160 (Vult) INTERNAL PRESSURE COEFFICENT = t 0.18 BLDG. CAT.=II, EXP.=C, MEAN ROOF HT. = 11'-3" PRESSURES HAVE BEEN MODIFIED PER FBCR 7TH ED. (2020) SECTION R301.2.1 TO MEET TESTED ALLOWABLE OR NOMINAL WIND LOAD VALUES FROM THE PRODUCT MANUFACTURER. CONTROL DATE, 01/01121 NOTE: SOFFIT INSTALLATION IS TO BE PER MANUFACTURER'S SPECIFICATIONS THAT ARE TO BE PROVIDED BY THE BUILDER WITH PRODUCT APPROVAL AND NOA SUBMITTALS. 7 Q a_ Review Con Universal DIM. VARIES XRCH DTL. SCALE: 1/2 = 1'-0" DBL. TOP PLATE I BAR DETAIL A SCALE: 1/2'=1'-O' 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 SUBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 ODEr.iiiii. 4EBB "1828—CALI" Ca-ARAGE SWING: RIGHT PAGE: FLOOR PLAN 160 MPH EXP. C ARCM ECT- STATE OF FLORIDA r°,AR 19 2221 WCHAEL C. ANDERSON AR NO 17305 PRINT DATE- 03 17 21 SCALE: 1 /4"=1' — O" L UAL EQUAL SHINGLE -oo DECORATIVE FOAM DRAIN �■ TILES 9p" RAISED - �f��- ` /0 w EQUAL EQUAL tO cONtROL JOINT TO CONTROL JOINT { _ -_--- - - --- / 19 0 SLDG. HGT — 12 �6 0 • • - m NO� �� o ICI ICI ICI ICI - - " - ICI I�I�I�I ICI - ' ■ 1 • — o — — — — o 8'=S° BRCS. HCsT.,h� 4' FRF 171= BAND -8'-0' BRCS. HGT. OPT. COACH �— LIGHT LIGzT. 1-0° ' 4B � A TYP. 0'-0" FIN. FLR. 11 415 Y11.I 0'-0" FIN. FLR.; _J Ll ---------- 4 OFF RIDC:E VENT 6 12 rtU FFMFI p -- ------ I I--'�O'-0" FIN. FLR. REAR ELEVATION SCALE: 1/4 = I'-0' TEXTURED FINISH 4B I 1 A3 I `r TTP I I r - - — - — - — - - - — -- - — - - - J J - - - — - — - - — - — - - — - — - — - ]SIGHT ELEVATION SCALE: 1/4 = 1'-0' TEXTURED FINISH ¢I OFF RIDGE VENT OFF RIDGE VENT 1�6 12 6� nE A 8'-8" BRCS. HCsT. — Y 4B v I A TYP. r 0'-0" FIN: FLR:__—___---_—_—_—_—_---_—_—_—_ ----- _—_—_---_—__- LEFT ELEVATION ----o5'-8" BRG. 1-ICsT. - o0'-0" FIN. 1=LR. `S" BRCS. HGT. 1_m, 0'-0" FIN. FLR. e®e. I\ 8, / DECO. DTL. A SGALE: 1/2 = I'-0' Reviewed for Code Compliance Universal Engineenng Sciences MODEL 1828-CALI-4EBB AREA OF ATTIC = 2450 SQ. FT. NET FREE VENTILATION AREA REQUIRED 1/ 300 REQUIRED VENTILATION AREA = 2450 /300 = 8.17 50, FT. 8.17 = 1176 SO, IN. MIN. REQUIRED VENTILATION = AX 1176 IN UPPER PORTION OF ATTIC = 470.4 SQ, IN. (BALANCE TO BE PROVIDED IN SOFFITVENTS) OFF RIDGE VENTILATION AREA = 138SQ IN. PER VENT (net free area) TOTALH OF VENTS REQUIRED _ 3.41 TOTAL# OF VENTS PROVIDED = 4 SOFFIT VENTILATION AREA 7 SQ. IN. PER LINEAR FT (net free area) LINEAR FEET OF SOFFIT REQUIRI 67.20 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA32937 PH: 321-802-359r www.abdesigngroup.com AA #: 0003325 Si733DIV. CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: ELEVATION "C" 160 MPH EXP. C ARCHnIECT: STATE OF FLORIDA MAR 1 Q 2021 MICHAEL C. ANDERSON AR NO 17305 0�T f PRINT DATE 03 17 21 SCALE: 1/4"=1' - 0 ;Z)T� kL4 SCALE: 1/4 = I'-0' TEXTURED FINISH m ELECTRICAL LEGEND YMBOL DEFINITION NOTES - ---- 3 125V OUTLET 20 AMP SINGLE r' I - I' 110V OUTLET Ill OUTLET 1/2OF OUTLET WILD TO SWITCH .-_ .-_.. GFI 110V OUTLET FAUL ERU IGRND INT INTIUID WMER (TAMPER RESISTANT TYPE) -' 220V OUTLET (4) WIRE CONNECTION 1 CFI CUTLET INTERRUPTERT SWITCH �LJ SWITCH 3-WAY OPER $4 SWITCH 4-WAY OPER 1 - WALL MOUNTED LIGHT CEILING LIGHT 7 Q LED CLG LIGHT O VP LED VAPOR PROOF LIGHT ..... O VP VAPOR PROOF LIGHT Q RECESSED CAN eVENT. FAN 1 CFM PER SO. FT, VENT. FAN W/LIGHT 1 CH'I PER 84 FT. VANITY LIGHT FIXTURE '. ' (SPEC'S TBD BY BUILDER) 4' FLUORESCENT CENT 2-BULB WRAP ii ® LIGHT ROIAIp A (RECESSED) ® 4'1 FLUORESCENT LIGHT 2-BUL15 WRAP AROUND (SURFACE MNT_) ]✓-� T FLUORESCENT 4' FLUORE6i 4' TRACK LIGHT ) ® PANEL METER BAIT. BMX -UP ' SMOKE DETECTOR W/ HARDWIRE I WALL MOUNTED BATT, BACK-UP SD. 201 SMOKE DETECTOR W1 HARDWINE u BATT. BACK-UP W/ CARBON MONOXIDE SMOKE DETECTOR COMBO 8Al DWIRE INTER -CONNECTED 61 BE A DISTANCE OF NOT LESS TERN 4' FROM WALL PENDANT LIGHT NATURAL GAS .... OUTLET TELEPHONE JACK WATER HEATER IGNITION SOURCE TO BE ELEVATED DISCONNECT AIR CONDITIONING -� TO BE 210V A/ DISCONNECT SE �UN,O. THIS SMET TELEVISION JACK CEILNG BOX REOUI1W TO BE SUPPORTED N O J-15OX ACCORDANCE W/ BOX • MARKED AS SUCH FOR INSPECTION CEILING BOX RTED TO BE SUPPORTED IN IN CEILNG FAAULKaFNT ACCORDANCE W/ BOX MARKED AS SUCH FOR INSPECTION nnn.a 24' INCANDESCENT LIGHT STRIP pn 36' INCANDESCENT LIGHT STRIP nnnnnnoe � 48'INCANpESCENi LIGHT STRIP FLOOD LIGHT OPT. SECURITY KEYPAD i PUSH-BUTTON FOR CHIMES 0i U85 PORT + LOCATION OF TV JACKS t PHONE OUTLETS a FANS To BE VERIFIED + HOMEOWNER PRE -CONSTRUCTION MEETING. ' ALL 15 4 20 AMP BRANCH CIRCUITS TO BE ARC FAULT PROTECTED PER ELECTRICAL PROVISIONS OF PECR 1TH EDITION (2020) t NEC 210.12 2011 EDITION. • 20 AMP DEDICATED LAUNDRY CIRCUIT. • GPI a ISLAND (NOT ON KITCHEN CIRCUIT) • DISHWASHER DISCONNECT TO BE LOCKAdT IN PANEL • BATHROOM EXHAUST FAN TO HAVE MN. CAPACITY OF 50 CRT INTERMITTENT PER ELECTRICAL PROVISIONS OF SECTION MIN"3 F5CR 1TH EDITION (2020). I • LAUNDRY ROOM RECEPTACLE SHALL BE GROUND FAULT CIRCUIT -INTERRUPTER PROTECTION FOR PERSONNEL ON FEEDERS • WIRING METHOD SHALL BE NON METALLIC CABLE PER ELECTRICAL PROVISIONS OF FBCR 1TH ED (2020). • ALL WOW TO COMPLY WITH ELECTRICAL PROVISIONS OF THE FBCR 1TH ED (2020) • ALL LAMPS SHALL BE SELECTED BY BUILDER AND 15X OF LIGHTING MUST BE ENERGY EFFICIENT TYPE PER FFSL- ENERGY CONSERVATION (RESIDENTIAL ENERGY EFFICIENCY) 2020. 1th EDITION R404) CE IL INfs MTD. LIGHT TO BE INSTALLED, PROVIDE J-BOX FOR OPT. FAN i J COVERED LANAI _ I PRE -WIRED CLG FAN \ DROOM LIVING BDRM.#i ROOM PRE -WIRED CLG FAN / / PRE -WIRED C\ ! — j CLG FAN qP\\ I II I qp SWITCH IN��—�_—��L CABINET _1 BATH Al GFI L _ L GFI - ori F P.I.C. LF SINK D -_ A / I OUTLET - -- T I T _ KITCHEN FOR DW LAUN.1 VP11 L \ _ GFI El CFI �I� 'a-AliI�-- - \ RANGE GF[ C) GFI i IQ q 1 BDRM -yl — DE ]i I - I / m �, l HOOD WIRE W/ — FUTURE OUTLET FOR MICRO / 820,11 SD. Q PRE -WIRED :'� ,. II CLG FAN ■ BBD�\ 1 F- T \ \ PRE -WIRED CLG FAN - BFOR -- - � 1 GFI GFI H Av S , 44'AFF. 44'Ai�. P.. f LU14 GARAGE DOOR' - L V ----� �BOL.LARD OND; y \ _ 3: I AS REQ. PER SLDG. CODE BATH 2 I - - -- 57c0 1 \ WALL MOUNTED _W -- -- / \ LIGHT W/SWITCH IN / \ ATTI r. KEYLESS OUTLET z METER BDRM f2 �J �'Q��$ FIXTURE 0�. FIELD / IRRIGATION LOC. OUTLET w P 48' ArP. ENTRY CsF l i J GARAGE PRE -WIRED -% CLG FAN B. FOR I- CHIMES EII Mil all -- _ -- _ ------------------ COACH LIGHT LECTRICAL PLAN SCALE: 1/4' = P-®' i L PANEL: 8/16 wp crt. breaker FEEDER: 3-#1CuTHWN&1-#6Cu(G)in11/2"C WP Panel MAIN - A VOLTAGE: 12U 1240 V -1 Ph MAIN: 15U Amp M.L.I3 OR 3- #2/0 AL THWN & 1 - #6 CU I in 1 1/2" C. Wire Pole Bkr Description Watts. Circuit Circuit Watts Description Bkr Pole Wire #12 1 20 Exterior Receptacle GFI for TUG 1200 1 2 4 :. Space #12 2 20 Irrigation Pump 1000 3 Space 5 6 5314 A/CCU -1 35 2 #6 Space 7 8 PANEL: 42 crt. breaker FEEDER: 3-#1CuTHWN&1-#6Cu(G)in11/2"C PANEL - A VOLTAGE: 120 / 240 V -1 Fri MAIN: 150 Amp M.L.O. OR 3- #210 AL THWN & 1 - #6 Cu I I n 1 1 12" C. Wire Pole Bkr Description Watts Circuit Circuit Watts Description Bkr Pole Wire #12 1 20 Small Appliance 1500 1 2 8000 Range 50 2 #6 #12 1 20 Microwave / Hood GFI 1800 3 4 #12 1 20 Small Appliance 1500 5 5 4500 Water Heater 25 2 #10 #12 1 20. Refrigerator 1500 _- 9 _ 8 10 #12 1 20 Dining Room Lights and Receptacles AFCI 15l 1200 Disposal GFI 20 1 #12 #12 1 20 Bath #2 GFI Receptacles 1200 1 I 12 1500 Dishwasher GFI 20 1 1 #12 #14 1 15 Foyer /Hall Bed. #2 & #;`/ Bath #2 Lights AFCI 900 13 14 _ _ _ 16 18 20 5900 Dryer GFI 30 2 #10 #14 1 15 Lining Room, Lanai. Lights AFCI 900 15 #14 1 15 Kitchen and Pantry Lights & Rcpts AFCI 900 17 19 _ 1500 Washer GFI 20 1 #12 #14 1 15 SD.&C/O AFCI 900 1000 Garage Door Opener GFI 20 1 #12 #12 1 20 Laundry / Bed#4 / Den AFCI 1200 21 22 1200 Garage Lights and Receptacles GFI 20 1 #12 Space. 23 _ 24 900 Bedroom #1 AFCI 15 1 1 #14 Space 2` 27 26 P. 9W Bathroom #1 AFCI 15 1 #14 Space 900 Exterior Lights and Recept GFI 15 1 #14 Space 29 30 1000 Irrigation controls only 20 1 #12 Space 31 32 Space Space 33 34 :. Space Space 35 _ 36 Space Space 37 38 Space #8 2 35 A/CAHU-1 (Heater 5 KVA at 65% 5525 39 40 _ Space 41 42 Space Load subject to demand factor calculations / line 16000 27600 Load subject to demand factor calculations / line Demand Factor Calculations: ABBREVIATIONS: AFCI: ARC FAULT CIRCUIT INTERRUPTER NC: NON -COINCIDENT LOAD GFI: GROUND FAULT INTERRUPTER Total load subject to demand factor 43600 First 10000 watts at 100% 10000 Remaining watts at 40% 13440 Total A/C load 10829 LOAD CALCULATION IS BASED ON MC NON -COINCIDENT LOAD Total Connected Load Watts 34269 Tots I Amps (watts / 240 volts) 142.8 General Lighting & Receptacle Load Total A/C Square Feet 1828 General Lts & Rec 3 W/ Sq. Ft. _�4 5484 Hi -Hats 1 at 65W/Li ht at 100% 65 Total General Lights &Rec (Watts) 5549 Ckts# watts/ckt Total watts General Lts & Rec Panel A 1 91 6171 5549 I Reviewed for Code I L ° Compliance I L ° Universal Engineenng Sciences LED LIGHTING C� DOUBLE LAV. BATH 01 150 AMP ELECTRICAL RISER NOT TO SCALE. GENERAL NOTES: A. ELECTRICAL MATERIALS AND INSTALLATIONS SHALL COMPLY WITH ELECTRICAL PROVISIONS OF THE POOR 1TH EDITION (2020). LOCAL CODES, AND ALL LOCAL POWER COMPANY REQUIREMENTS. B. ALL CONDUCTORS SHALL BE TYPE THHWtHWN UNLESS NOTED OTHERWISE. POWER COMPANY TRANSFORMER GRADE PROVIDE 150 AMP, 120/240 VOLT, 1 PHASE SECONDARY ELECTRICAL SERVICE. Plili 3 'N COPPER (CU) IN 1-1/2" DIA SCHEDULE 80 PVC CONDUIT OR PROVIDE 3 42/0 ALUMINUM (AL) IN 2" CIA SCHEDULE Be PVC CONDUIT UNLESS SERVICE IS PROVIDED BY THE ELECTRIC COMPANY. COORDINATE WITH THE ELECTRIC COMPANY PRIOR TO BID. LED LIGHTING C SINGLE LAV. BATH e2 PROVIDE 342/0 CU, THIN + 1% CU N 2' CONDUIT OR 3 04/0 AL, THWN + 1% CU IN 2' CONDUIT OR 2/0 AL. S.E.R. (CONDUIT TO TERMINATE ABOVE SOFFIT • OVERHANG-) 0 00MBINATION SERVICE 150 AMP DISCONNECT SWITCH AND 120/240 VOLT ELECTRIC METER IN I 44ASE NEMA 3R ENCLOSURE MILO PANEL 19_0 MC15 TELEPHONE SERVICE ENTRANCE EQUIP1111- T INTERSYSTEM BONDING TERMINAL AT LOW VOLTAGE CONNECTIONS CABLE TELEVISION SERVICE ENTRANCE EQUIPMENT — 1 +4 CU SERVICE GROUND C011ii Ep TO CONCRETE ENCASED FOOTER STEEL PER ELECTRICAL PROVISIONS OF THE FECR 1TH EDITION (2020). We" 91A X B Fir LONG COPPER CLAD GROUND ROD 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH. FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com Ilit AA #: 0003325 c CREEKSIDE PHASE 2 LOT #2'7 PROJECT# 04321.200 027R1 MODEL 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: ELECTRIC t,11- PLAN 160 MPH EXP. C f' ARCHITECT( STATE OF FLORIDA i AR 19 202 I MAEE: 03/17/21 SCALE: 1 /4"=1 01 SHEET 11 E I I. G I e 11 C'❑� L•JI•I ' El - -- - F. } I. n, I I I�'-911 r Li 1 � I 44 - LAV. _ WC. a4 r - - - — LAV. LI SINK _ -- - r SWLJR PAN W/ ENCL 3'-2 1 �r j � II II I LI 7 6 T II -2" — — I e 11 C'❑� L•JI•I ' El - -- - F. } I. n, I I I�'-911 r Li 1 � I 44 - LAV. _ WC. a4 r - - - — LAV. LI SINK _ -- - r SWLJR PAN W/ ENCL 3'-2 1 �r j � II II I LI 7 6 T II -2" — — -- - -II fi PLUMBING PLAN SCALE: 1/4 = 1'-0' A.A.V TU5 "j(-2 TO CO MAIN (LEFT) KITCHEN SINK W/ AUTO VENT �1-I/2' VTR WG A.A 2LAV ' iISHWR Reviewed for Code iCompliance Universal Engineering Sciences TO MAIN (ALTERNATE RIGHT) PLUMBING RISER DIAGRAM 2194 HWY A1A, SUITE 301 INDIAN,HARBOUR' BEACH, : FLORIDA 32937 PH:321-802-3591 www.abdesigngroup.com AA #: 0003325 CREEKSIDE PHASE 2 LOT #27 PROJECT* 04321.200 027R1 MODEL: 4EBB "1828-CALI" sARAGE SWING: RIGHT PAGE: PLLMBING PLAN 1 a (I EXR C ARCHITECT.ter= STATE OF FLORID f, 1. MAR -1 9.2021 MICHAEL C. ANDERSON AR NO 17305 FRI DATE:03/17/21 SCALE: 1/4"=1'-I 9 SHEET P 11 d I L• °J •II•I o' LANAI I I �I ❑ LI L11__- CJ _ 1 _ i I•I I•I I. L•I �' n 12X12 12XI2 J DINING LIVING ROOM ROOM BDRM #1 F 10X(O II 10X6 L 120 CFM i 4X6 I I CFM 120 GFM 8X4 �.{S✓ CFM r 50 If BATH # 1 rI 8x4 e e — 5 CFM W.I.C. _ _7L11@ SX4o45 CFM II I I Ir I ImX6 Y 120 CFM --- SX4 I GFM HI TCHEN _ 45 GFM -- I --- IOX& - - �5 CFM I — — U' N I2Xi6 12X8 MA�ONITE P19w TH U BDRM. 3 < I LOUVER l I 4 � � DEN ' IDLANTATION I b e 180-04 2'8' G 10X6 MAX A R l5 GFM 584.15 G RA I" I 5� - - � 12X8 - Ss �_ 8x4 — I� 45 GFm Le � 55C�_ - ——� GFM r I I 12X8 �--THRU BA H I PASS GARAGE L 10XFi I 1: 0 CFM FOYER BDRM. 2 / ENTRY II --� - - CJ ❑ = r � LJ L• ij I.11 I • II L• �I AL PLAN MECHANICAL ANl� SCALE: 1/4 = 1'-0' Reviewed for Code Compliance LM Universal Engineering Sciences R—VALUE SCHEDULE FLOOR SLA5 ON GRADE R-0 EXTERIOR WALLS CMU - INT INSUL R-4.1 FRAMED WD - ADJACENT R-13 FRAMED WD - EXTERIOR R-13 CEILINGS UNDER ATTIC R-30 CRF4::]KSID� ' PHASE 2- P LOT #27 ROJECT 04321.200 027R1 MODEL: G 4EBB "1828—CALI" •ARAGE SWINGE: RIGHT 'PAGE: MECHANICAL PLAN L0 MPH EXP. C , PRINT 03 17 21 DATE• / SCALE 1/4" 1' 3" SHEET A/11 2X4 TOP PLATE , HR-6 1/2' CLG. 1/2' DRYWALL SECURE BT. — PL.ATE TO SLAB W/ 10d MASONRY NAIL a 32' O.G. MAX JSS 2X4 WOOD STUDS e24' O.G. SLAB NOTE: STUDS IN PARTITIONS SUPPORTING WALL HUNG: PLUMBING FIXTURES AND WALL CABINETS SHALL BE NOT LESS THAN 2x4, WHERE SPACED NOT MORE THAN 16" O.G. OR, NOT LESS THAN 2x6, WHERE SPACED NOT MORE THAN 24" D.G. TYP. INT. WALL (NON-BRG. SCALE: 3/4' = I' -0' FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR T105.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE PRE-ENG TRUSS MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS TYP. VENTED SOFFIT 1/2' THICK, 2 GOAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0-0" FIN. FLR " 3 5/8' OR 5 3/5, 1/2' DRYWALL TOP CHANNEL (25 GA.)3 5/8' OR 5 3/8' 1/2' DRYWALL METAL STUDS 24' O.G. 20 CIA METAL TO BE INSTALLED IN WALLS 3 5/8" OR RECEIVING UPPER/ 5 3/8" LOWER CABINETS BOTTOM AND TUB/SHOWER 25 CHANNEL GA. METAL TO BE (25 GA-) INSTALLED IN ALL SECURED OTHER WALLS. STUDS TO CONG TO BE SPACED 16' FLOOR W/ O.G. AT 2ND FLOOR 3/4" PAP t WALLS ADJACENT TO TO WOOD STAIR WELLS AND FLOOR W/ BATHROOM WALLS W/ 1/4' WOOD TILE FINISH SCREW WOOD BASEBOARD--�, 1-STORY FINISH FLOOR TYP. INT. WALL METAL STUDS A\ ( NON- BRG. ) -%-I / SCALE: 1/2"=1'-O' 5/5' GYPSUM BOARD OR 1/2' HIGH STRENGTH CLG. BOARD PER ELEVATION-, SEE ENERGY CODE FORMS INSULATION R-VALUES REFERENCE STRUCTURAL J PER ELEVATION `—R-4.1 INSULATION WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS REFERENCE STRUCTURAL Ix2 P.T. FURRING STRIPS a 24' O.G. S' CMU 1/2' GYP. WL. BD. WOOD BASE BOND BEAM SOLID GmROUi W/ (1)- "5 (2) COURSE FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR S05.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNI. SECURED PER FASTENER SCHEDULE STRUCTURAL �— PRE-ENG TRUSS MTL. DRiP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT 2A'�PIPE THROUGH BOND BEAM D1J SCALE: 3/4'=1'-0" 1/2' THiCK, 2 COAT PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0' FIN. FLR ROOF SHEATHING THICKNESS IS ENGINEERED PER ASCE -i-16 IN ACCORDANCE WITH FBCR 2020 ITH EDITION, SECTION R301.13 AND 16095.1. n W/ WINDOW OPENING B TYP. WALL SECTION NO OPENING NOTE: METHOD TO BE USED FOR THE 4 1-STORY HIP BLOCK WALL INSTALLATION OF ROOF D1 SCALE` 3/4'=I'-O' UNDERLAYMENT IN ACCORDANCE WITH FBCR 905.1.1.1 OF THE FBCR 2020 7TH EDITION iS 1*4 WHICH USES (2) TWO LAYERS OF ASTM D226 TYPE iI OR ASTM D4869 TYPE III OR TYPE IV UNDERLAYMENT. FIBERGLASS SHINGLES WITH UNDERLAYMENT AS PER FBCR S05.1.1. ROOF SHEATHING THICKNESS AS PER SHEET SNi. SECURED PER FASTENER SCHEDULE MTL. DRIP EDGE 2x FASCIA PER ELEVATIONS VENTED SOFFIT WALL SHEATHING THICKNESS AS PER SHEET SNI. SECURE PER FASTENER SCHEDULE ON SHEET SNI PRE -ENG. GABLE TRUSS WEEP SCREED 2x P.T. SECURED PER STRUCTURAL DETAILS 1/2' THICK, 2 COATy` PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY 0'-0" FIN. FLR 8' CMU \ CAULK ANDSEAL LINE D NOT CUT I i' PVC SLEEVE FOR GAS LINE 4E BOND s' CM E AM w G7P. EBARS /FWD°° eaeE 2B GAS LINE THRU BLOCK D1 .GALE. M'.I,-m. IF1' THICK, 2 COAT - PORTLAND CEMENT PLASTER APPLIED DIRECTLY TO MASONRY GALV. STEEL _.--- 9 '- TRACK BRACKETS FASTENED TO WOOD JAMB PER PRODUCT GALV. STEIEEL�4 APPROVAL REa VERTICAL TRACK 1' MIN. BY MALF. SLIDE FASTENED TO ROOM BRACKETS W/ PRODUCT APPROVAL REQ. a, CMU SEE SMCTURAL FOR REINFORCEMENT 2xb P.T. WD ATTACHED To FILL CELL AS PER PRODUCT APPROVAL REa SEALANTt BACKER ROD WEATHER STRIP MOULDING ALL AROUND(BY DOOR MANUF.) OVERHEAD DOOR BY OTHERS GARAGE DOOR JAMBS SCALE: 1 1/2"=1'-O' FIBERGLASS SHINGLES 2X4 SPF 24' O.C. MAX. WITH UNDERLAYMENT SECURE W/ (2) 12d NAILS AS PER FBCR S05.1.1. a EA. END ROOF SHEATHING 2x BLOCKING BETWEEN TRUSSES THICKNESS AS PER PER STRUCTURAL DETAILS SHEET SNI. SECURED PER FASTENER SCHEDULE STIFFBACK AT ALL UPRIGHTS PER STRUCTURAL DETAILS MTL. DRIP EDGE MAx PRE-ENG WD. TRUSS Ax 2x FASCIA PER o H ELEVATIONS — PER ELEVATION VENTED SOFFIT CONT. 2x RAT RUN SECURED PER STRUCTURAL DETAILS WALL SHEATHING SEE ENERGY CODE FORMS FOR INSULATION R-VALUES THICKNESS AS PER PER ELEVATION SHEET SNI. SECURE PER FASTENER SCHEDULE 5/8' GYPSUM BOARD OR 1/2' ON SHEET SNI. HIGH STRENGTH CLG. BOARD PRE-ENG. GABLE TRUSS I WEEP SCREED 2x P.T. SECURED PER R-4.1 INSULATION STRUCTURAL DETAILS WINDOW ATTACHMENT AS PER MANUFACTURES SPECIFICATIONS FERENCE I - STRUCTURAL 1x2 P.T. FURRING L STRIPS a 24' O.G. 1/2' GYP. WL. BD. WOOD BASE 8' CMUL. _ 0'-0' FIN. FLR 110 ROOF SHEATHING; THICKNESS IS ENGINEERED PER ASCE -t-16 IN ACCORDANCE WITH F 2Fq ITH EDITION, SECTIO 1.1.�omdfor Code cliance AND 1609.5.1. Univesae ngi ernng Sciences n W/ WINDOW OPENING_ n TYP. WALL SECTION `� U No OPENING NOTE: METHOD TO BE USED FOR THE STORY GABLE BLOCK WALL INSTALLATION OF ROOF SCALE: 3/4'=r'-O' UNDERLAYMENT IN ACCORDANCE WITH FBCR SO5.1.1-1 OF THE FBCR 2020 ITH EDITION IS *4 WHICH USES (2) TWO LAYERS OF ASTM D226 TYPE 11 OR ASTM D4869 TYPE I i I OR TYPE IV UNDERLAYMENT. Note: WALL FENESTRATION FLASHING PER FBCR 703.4 - Approved corrosion -resistant flashing shall be applied shingle -fashion in a manner to prevent entry of Water into the wall cavity or penetration of water to the building structural Framing components- Self -adhered membranes used as flashing shall comply with AAMA -1I1. All exterior fenestration products shall be sealed at the ,juncture With the building wall With a sealant complying With AAMA BOO or ASTM CS20 Class 25 Grade NS or greater for proper Joint expansion and Contraction, ASTM C1281, ,AAMA 512, or other approved standard as appropriate for the type Of sealant. Fluid -applied membranes used as flashing in exterior walls shall comply With AAMA 114. The flashing shall extend to the surface of the exterior wall finish. 2194 HWY A1A. SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 SUBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP. C ARCHrrECT: MAR 19 2021 PRINT DATE: 03 17 21 SCALE: 1/4"=1' — 0" SHEET DI I TOP- 2X6 P.T. • CENTER OF DOOR HEADER SECURED W/ (1) 1/21 X B' J-BOLT W/ 4' MIN. EMBEDMENT W/ 2' X 2' X 1/8' WASHER 4 NUT OR W/ (2) 1/2' X 8' ANCHOR BOLTS W/ 4' MIN. EMBEDMENT W/ 2�' X 2' XX1/5' WASHER 4 NUT 'SECURE 2x4 ON — FLAT TO BLK Lj W/ MASONRY J NAILS. SIDES: 2X6 GARAGE DOOR BUCK SECURED W/ (5) 1/2' X 8' J-BOLT OR ANCHOR BOLTS, W/ 4' MIN. EMBEDMENT, W/ 2' X 2' X 1/0' WASHER 4 NUT. (1) WITHIN 8' OF TOP, lU WITHIN W OF THE BTM, (3) EVENLY SPACED. I^-rl lx4 P.T. OR 5/4'X4' MIN. SECURE THRU FRAME 4 EXTEND 1-1/4' INTO BLOCK W/ 3/I6' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1-1/4' WITHIN 8' OF EACH END 4 18' OZ. MAX SPACING NOTES: — ALL ANCHORS SHALL BE IN ACCORDANCE TO MANUFACTURER'S INSTALLATION INSTRUCTIONS WHEM SUCH INSTRUCTIONS ARE MORE STRINGENT GARAGE DOOR i' BUCK ATTACHMENT 8' CMU 1/2' DRYWALL I'X4' P.T. NAILER DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/4') DOOR JAMB TO BLOCK +3/4" OR +5/4" �1YIND011 TO BLOCK +3/4" OR +5/4" 2X4: IZI SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 IV O.C. MAX SPACING. 2X6: CEC SECURE TO BLOCK WK2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN W OF EACH END 4 18' O.G. MAX SPACING. 2X8: CEM SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE J45 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. I 8' CMU 1/2' DRYWALL I'X4' P.T. NAILER DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +1 1/2" B WINDOW► TO BLOCK +1 1/2" 2X4: SECURE TO BLOCK W/ 3AW TAPCONS (MIN. SHANK SIZE J45 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/40) WITHIN S' OF EACH END 4 18' Or— MAX SPACING. 2X6: CEM SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN_ SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN W OF EACH END 4 18' O.C. MAX SPACING. 2X8: CEO SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 15' O.C. MAX SPACING. 2X4: CM SECURE TO BLOCK W/3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X6: CEO SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') 8' CMU WITHIN W OF EACH END S' CMU 4 10' Or— MAX SPACING. 1/2' DRYWALL 2X8: ® ❑ 1/2' DRYWALL 1'X4' SECURE TO BLOCK I'X4' P.T. NAILER W/(2) 3/16' TAPCONS P.T. NAILER l/16' 0SU3. X 4' MIN. (MIN. SHANK SIZE .145 DOOR CASING MIN. HEAD SIZE 300 DOOR CASING MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 18' O.G. MAX DOOR JAMB OR WINDOW SPACING. DOOR JAMB OR WINDOW ATTACH TO 2X PER ATTACH TO 2X PER MANUFACTURES DETAILS. MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +1 15/16" (;N1fINDOW TO BLOCK +1 15/16" 2X4: IZI SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. 2X6: CEM SECURE TO BLOCK WK2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 IS' O.C. MAX SPACING 2X8: SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4.) WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE ON OUTSIDE 4 SECURED THROUGH NON-STRUCTURAL 3/16' TAPCON MIN. 1-1/4' EMBEDMENT INTO BLOCK. 8' CMU ❑ 1/2' DRYWALL I'X4' P.T. NAILER DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +2 1/4" D WINDOW TO BLOCK +2 1/4" NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +3" %1WTN�O�f TO Ri.OrK +A" 2X4: IZI SECURE TO BLOCK W/ 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X6: CEM SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE;.45 MIN. HEAD SIZE 100 MIN. EMBEDMENT 1 1/4') WITHIN W OF EACH END 4 18' O.G. MAX SPACING. 2X8: CEO SECURE TO BLOCK W/(2) 3/16' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 18' OiC. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE ON OUTSIDE 4 SECURED THROUGH NON-STRUCTURAL 3/16' TAPCON MIN. 1-1/4' EMBEDMENT INTO BLOCK. L�j 8' CMU 1/2' DRYWALL I'X4' P.T. NAILER DOOR CASING 2ND 2X SECURE TO STRUCTURAL MEMBER W/(2.A2d WITHIN 8' OF EACH END 4 6' TO 8' O.C. MAX POOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURF'A r]FTAII A Nv I= aFUI-I f V IYppLCU I V r-L.UI-R7 JAMB (DO NOT EXCEED 1/49 DOOR JAMB TO BLOCK +3" �1PINimOW TO Ri.00K +3" 2x4: CM SECURE TO BLOCK W/ 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 11/49 WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X6: CED SECURE TO BLOCK WK2) 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 18' O.C. MAX SPACING. 2X8: SECURE TO BLOCK W/(2) 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN 8' OF EACH END 4 10' O.G. MAX SPACING. 8' CMU ❑ 1/2' DRYWALL I'X4' P.T. NAILER T/I6' O.S.B. X 4' MIN. i— DOOR CASING DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/47 DOOR JAMB TO BLOCK +3 7/16" r,"NWINDOW TO BLOCK +3 7/16" 2X4: CM SECURE TO BLOCK W/ 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/42) WITHIN 8' OF EACH END 4 18' O.G. MAX SPACING. 2X6: CEO SECURE TO BLOCK W/(2) 1/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/4') WITHIN W OF EACH END 4 IS' O.C. MAX SPACING. 2X8: CM SECURE TO BLOCK W/(2) I/4' TAPCONS (MIN. SHANK SIZE .145 MIN. HEAD SIZE 300 MIN. EMBEDMENT 1 1/49 WITHIN W OF EACH END 4 18' O.C. MAX SPACING. NOTE: STRUCTURAL 2X MUST BE ON OUTSIDE 4 SECURED THROUGH NON-STRUCTURAL 3/I6' TAPCON MIN. 1-1/4' EMBEDMENT INTO BLOCK. L—VI 8' CMU 1/2' DRYWALL 1'X4' P.T. NAILER 1' P_t. X 4' MIN. r DOOR CASING �— DOOR JAMB OR WINDOW ATTACH TO 2X PER MANUFACTURES DETAILS. NOTE: SHIM AS NEEDED TO PLUMB JAMB (DO NOT EXCEED 1/4') DOOR JAMB TO BLOCK +3 3/4" WINDOW TO BLOCK +3 3/4" Reviewed for Code Compliance Universal F_ngineenng tu Sciences CMU O :' • %' DRYWALL lu IX FURRING X m RIP 2XIO TO DOOR 8-1/80W FRAMING HOLD FLUSH TO INTERIOR FACE OF DRYWALL ENTRY DOOR BUCK �EQUIREMENTS 1: R 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. a b d es i g ngro u p. com AA #: 0003325 00 sysDIV. & LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: DETAILS 160 MPH EXP. C "92021 MICHAEL C. ANDERSON AR NO V305 DATE: DAT : 03 17 21 SCALE: 1/4"=1'-0" 1 a NOTE: IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES ;I ED CONTROL JOINT THICK, 3 COAT CEMENT FLANGE OF CONTROL JOINTS T / \ PLASTER BE WIRED TIED TO LATH • S' WRB LAYER 92, FORTIFIBER O,C. MAX (VERT.) HOTS: DO BUILDING PAPER NOT FASTEN CONTROL JOINT TO WALL EVEN IF STUD EXISTS BEYOND EXCEPT STAPLES W/ APPROVED METAL LATH V LEG'MAY BE USED TO TEMP. FASTENED 411' (VERT.) O.G. MAX SECURE CONTROL JOINT AT SUPPORTS DURING INSTALLATION WRB LAYER M, FASTENERS TO BE SPACED STUCCO WRAP B T' O.G. MAX VERTICALL7 WOOD SHEATHING EHING OR 1/16' ZIP SHAT I bYBTEM NNSTALLED PER I , ., MAyUF; GSJ d' To LATH SHALL NOT GAP MIN. - BE CONTNUOUS 6' To S' MIN. S' TO 6' MIN. THROUGH CONTROL JOINTS BUT SHALL BE STOPPED AND TIED AT EACH SIDE. PROVIDE 2X4 BLOCKING PER ASTM C1063 \ PLACED FLAT MAX. 6' TO 8' L JOINT WHEN T FALLS ON CONTROLFROM JOINT NOTE= \ TO NAILS OR STRUCTURAL STUD 1. FASTENERS FOR LATH BE STAPLES IN COMPLIANCE W/ ASTM C1063 2. WIRE TIES TO BE (NO. 18) 0.0415' WIRE 3. BLOCKNG SHOWN MAT BE IN ADDITION/ \ TO WALL STUDS REQUIRED PER PLAN M- TYPE CONTROL I JOINT O I. FOLD INWARD • Pr. A O 1. FOLD INWARD • PT. A 2. CREASE w Pr. B a OI. FOLD INWARD PT. A 2. CREASE • PT. B 3. CREASE • PT. C FOLD J. I (151 ® 1. FOLD INWARD • PT. A 2. CREASE • Pr. B 3. CREASE • Pr. C 4. FOLD PT. G OVER PT. B TILL PT. C TOUCHES BOTTOM FLANGE BOTTOM FLANGE WATER TIGHT SEAL FOLD. DQ IF ZIP SHEATHING SYSTEM IS dQT CUT. INSTALLED, PLEASE SEE is THICK 3 GOAT CEMENT MANUFACTURERS PLASTERASTER ('2 COAT 'W INSTALLATION PROCEDURES WR5 LAYER 02, FORTIFIBER BUILDNG PAIER(FRAME ONLY) FELT LINDERLAYMENT— BHMRI F ROOFING RIP S DEPO. OVERLAP V, EXTEND 1/2' BELOW SHEATHMG, MECHANICALLY FASTEN 4' Or —MAX ///���UJI¢B LAYER M, / STUCCO WRAP aw E ONLY) / LAP LAYERS OF 19UII-PING WRAP OVER NAILMG FLANGE, STOP WRB APPBPX IV ABOVE 814NGLES(FRM`E ONLY) 8.h ... FRAME OR CM /N .. EXTERIOR \ c(rsnrui L nr�can ll WALL FLASHNG in �QO r a K CK OUT ii_ABHN13 (SEE DETAIL) g' NOTE: APPROVED BUILDING WRAP SHALL BE LAPPED A MINIMUM OF 6' • VERTICAL LAPS (ROLL S) < 6' • HORIZONTAL LAPS. A L SEAMS NEED TO BE TAPED LATH VERTICAL LAP TO BE Is W TH FORTIBER SHEATHING TAPE / I" MIN. LAP q METAL LATH X I X W eX X METAL LATH WRB LATER M, / STUCCO WRAP 6' MINPAPER LAP BELOW ONLY / WRB LAYER 02, FORTIFIBER BUILDING PAPER y 1' MIN LATH LAP, 4' OVER ALL LAP @2-TAPER LAP SCALE: 1 I/2' = I'-0' ® KIC KO UT FASCIA WRAP DETAIL WATER TIGHT SEAL (BEND OR SOLDER DO NOT CUT) i' z Y_ IN NOTE: IF ZIP SHEATHING SYSTEM 15 INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES i' THICK, 3 COAT CEMENT PLASTER METAL LATH WRB LAYER 62, FORTIFIBER BUILDING PAPER WRB LAYER M, STUCCO WRAP WOOD SHEATHING OR 1/16' ZIP SHEATHING SYSTEM (INSTALLED PER M,fWUF. SPEGSJ VERTICAL LATH & PAPER DETAIL WOOD STUDS - SHEATHING NOTE; SIDE LAPS OF METAL OR IAIV ZIP SHEATHING SYSTEM (INSTALLED PER MANLLF.9PEC8J PLASTER BASES SHALL BE SECURED TO BUILDING FRAMING MEMBERS. PAPER THEY SHALL BE TIED BETWEEN SUPPORTS WITH 0.0415-IN. (121-MM) STUCCO WIRE AT INTERVALS NOT MORE THAN V (229-MM). AS PER ASTM CI063. NOTE: 6' MIN. LAP LAP o LATP LAP.a PAPER FOR REPAIR OF TEARSIN WR5 HORIZONTAL LATH MAY BELPATCHED MARS & PAPER DETAIL W/HOUSE WRAP TAPE PER MANUF. SPEC. OR PEEL t STICK ROOF CEMEN 7/16' ZIP SHEATHING SYSTEM (INSTALLED PER WORM- SI—IEAIPING OR CMU WRB LATER 01, STUCCO WRAP (FRAME ONLY) 8" THICK, 3 COAT CEMENT PLASTER (FRAME), 1/2 2 COAT CEMENT PLASTER (CMU) METAL LATH (FRAME ONLY) LAP U)RB 4 TAPE OVER ROOF/WALL SCREED 5"X5" "L" TYPE CONTINUOUS GALV. METAL FLASHING (NAIL TO ROOF DECK, NOT WALL SHEATHING) CAP SHINGLE — DO NOT NAIL, INSTALL WITH ROOF CEMENT ROOF PER ELEVATIONS s 5 „ L" FLASHING N.T.S. 4'x4' SELF -ADHERING MEMBRANE FLASHING (COMPATIBLE W/ HOUSE 7� WRAP MATERIAL) OVER APPROVED HOUSE WRAP. FLASHING TO EXTEND ONTO PIPE I' OR LESS PIPE PENETRATION Vx6' SELF -ADHERING MEMBRANE FLASHING (COMPATIBLE W/ HOUSE WRAP MATERIAL) OVER 4'x4' SELF -ADHERING MEMBRANE FLASHING OVER APPROVED HOUSE WRAP. FLASHING TO EXTEND ONTO PIPE GLLT AND OVERLAP ONE SIDE ' SELF -ADHERING MEMBRANENE FLASHING CUT AND OVERLAP ONE 81DE OF STEP M STEP "2 SELIFI-IINIGHERING MEMBRANE FLAS L NI LAYER M, STUCCO WRAP WRB LAYER 02, FOR'TIP15ER BUILDING PAPER METAL LATH 6'x6' SELF -ADHERING MEMBRANE FLASHING OVER 4'x4' SELF -ADHERING MEMBRANE FLASHING OVER APPROVED INSTALL FASTENERS (CLIPS,- HOUSE WRAP. STRAPS, STAPLES) AS FLASHING TO EXTEND ONTO PIPE REQUIRED TO SECURE 4'x4' SELF -ADHERING MEMBRANE PIPE/ WIRE TO FRAMING FLASHING OVER APPROVED HOUSE WRAP- - - FLASHING TO EXTEND ONTO PIPE I ' Cow. BEAD OF SEALANT '— NSTALL APPROVED HOUSEWRAP AIR INFILTRATION BARRIER OVER SHEATHING ELASTOMERIC COATING OVER STUCCO/ G.V. FINISH (SEE TYP WALL SECTION) SECTION NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES i�f P PENETRATE ON DE N.T.S. PER SECTION R703.7 Exterior lathing and plastering Exterior use of portland cement plaster shall comply with the application requirements of ASTM C 926-18h. Installation of exterior lathing and framing shall comply with ASTM. C1063-19a, or ASTM 1787. TAIL (f=fRArsss#s! Reviewed for Ccae Compliance Universal Enginecnn,_, LEGE � 1B Sciences N DRAINAGE PLANE (WR5 LA4� ER #1/ STUCCO WRAP) WRB LAVER #2 (FORTIF15ER - — — 5UILDING PAPER) 1"'IETAL LATH X X X X STUCCO WOOD OR T/16II ZIP WALL SHEATHING SEL1--ADHE51VE FLASHING — — — — — NOTE 1 ITAL LATH: LATH TO 8E PER SECTION R-103-7.1 / A5T1�I C-847-14a 1�1IN. 2.5 L55. PER SQ. YAi;RD ( UT I L I T%r OR NO1`1 INAL LATH DOES NOT 1„IEET SPECIFICATIONS) SUBDIV. & LOT: CRE'EKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 MODEL P 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: a_ �1 WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHRECT: STATE OF FLORIDA r; MAR 11 202',, I� MICHAEL C. ANDERSON AR NO 17305 03T 21 (URAIT]EI:/17 / SCALE: 1/4"=1'-0" SHEET WAS NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES I • - v BACKER ROD WRB LAYER "I, STUCCO WRAP " INSTALL 6' SELF -ADHERING MEMBRANE FLASHING OVER TOP, SIDES) AND BOTTOM FLANGES OF NON -MOVABLE FRAME OF THE EXHAUST. SEQUENCE OF FLASHING TO BE: 1. BOTTOM, 2. SIDES, 3. TOP VENT CAP 15 TO BE SET IN BED OF SEALANT AT TOP AND SIDES ONLY. SEALANT IS TO BE TOOLED SO AS TO DEFLECT WATER AWAY FROM JOINTS. E-Z BEAD ALL AROUND VENT -APPLY SEALANT ALL JOINTS AND INTERSECTIONS APPLY SEALANT AT PERIMETER OF NON -MOVABLE FRAME AND STUCCO ON ALL SIDES, Y4' CAULKING ® JOINT ALL AROUND i' THICK 3 COAT CEMENT PLASTER METAL LATH WRB LAYER 02, FORTIFIBER BUILDING PAPER WOOD SHEATHING (FRAME) LEGEND DRAINAGE PLANE (WRB LATER 01, STUCCO WRAP) WRB LAYER #2 0F0RT11=15ER — — — — — BUILDING PAPER METAL LATH X—X—X—X STUCCO WOOD OR 1/16" ZIP WALL SHEATHING SELL= —ADHESIVE FLASHING NOTE: METAL LATH: LATH TO BE PER SECTION R-103.11 / ASTM C-841-14a, MIN. 2.5 LBS. PER 5CQ. YARD (UTILITY OR NOMINAL LATH DOES NOT MEET SPECIFICATIONS) ELEC. METEf VERIFY LO -STUCCO FINISH -6' SELF ADHESIVE OVER TOP E SIDES FLASHING UNIT PREMANUF. DRYER VENT CAP (SET IN CONT. SEALANT) SEALANT 6 TOP d SIDES 9 DRYER VENT (BLOCK) BUILDING PAPER OVER 'QUICK FLASH' —I PIPE THROUGH WALL 6' SELF ADHESIVE — FLASHING (INSTALL PER MANUR SPECS.) BUILDING PAPER UNDER 'QUICK FLASH' l/ i t=: IF IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES �1VENT PENETRATION ti SCALE: N.T.S. /Am=A ICJ rl<=Ll=I Vt STUCCO SCRATCH COAT E 1 COAT OF PAINT W/BACK- ROLL PRIOR TO ELEC. METER INSTALLATION ELEC. METER FIELD VERIFY LOCATION APPLY STUCCO SCRATCH GOAT AND ONE (1) LAYER OF PAINT PRIOR TO INSTALLING ELEC. METER CAVITY TO BE FILLED WITH RIGID POLYMERIC ISOCYANOTE-POLYBLEND FOAM . "t el"t i--° SIMILAR) APPLY A SILICON BASE SEALANT AT POINT THAT ELEC. WIRE PENETRATES ;O SCRATCH COAT LARGER THAN THE ELEC. METER CAN OR METER CAN COMBO OR METER CAN AND DISCONNECT 8 ELECTRIC,AL CONDUIT PENETRATION WOOD CONSTRUCTION WOOD SHEATHING LAYER 01, STUCCO WRAP WRB LAYER 02, FORTIFIBER BUILDING PAPER METAL LATH I/8' TEXTURED f ^FINISH 0 WOOD FASTEN TO WOOD STRUCTURAL i MEMBER a 71' O.C. MAX s Ye' TO 19 MID -WALL WEEP SCREED IL 16' WIDE STRIP SELF ADHESIVE FLASHING, CLEAN MASONRY BEFORE APPLYING _TEXTURED FINISH • MASONRY 7B HORIZONTAL WEEP SCREED FRAME TO BLOCK CUT OPENING IN APPROVED HOUSEWRAP FOR BOX INSTALLATION WRB LAYER *I, STUCCO WRAP WOOD SHEATHING APPROVED HOUSEWRAP BELOW CUT SUCH l NO MEMBF ENTERS E APPLY TO F E APPLY E-Z BEAD OVER 60 MIN GRADE 'D' FELT -PROVIDE SEALANT AT ALL JOINTS AND INTERSECTIONS STEF Il STEF #3 y .o o. O O. ,. o o a• STEP "E-� OELEC_ T NOTE: IF ZIP SHEATHING SYSTEM IS INSTALLED, PLEASE SEE MANUFACTURERS INSTALLATION PROCEDURES 0 WRB LAYER 01, STUCCO WRAP CUT 'X' INTO SELF -ADHERING �X� MEMBRANE FLASHING APPLY SELF -ADHERING MEMBRANE FLASHING OVER BOX AND OVER APPROVED WRB LAYER "1 STEP' 1*2 WRB LATER 01, STUCCO WRAP APPLY 60 MIN SELF -ADHERING GRADE 'D' FELT MEMBRANE FLASHING OVER SELF -ADHERING Ell FLASHING OVER APROVED HOUSEWRAP WRB LAYER 02, FORTIFIBER BUILDING PAPER STEF #4 ELASTOMERIC COATING OVER STUCCO/ C.V. FINISH (SEE TYPICAL WALL SECTION) METAL LATH Reviewed for Code universal M hance Engineering 93 Sciences STEF #(q RICAL RECEPTACLE 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 SUBDIV. & LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 MODEL: 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. C ARCHffECT STATE OF FLORIDA MAR 19 2021 MICHAEL C. ANDERSON AR NO 17305 ""`" DATE: 03 17 21 SCALE: 1/4"=1'-0" SHEET �nMMM - !194 HWY A1A, SUITE 30: INDIAN HARBOUR BEACH FLORIDA 32937 PH: 321-802-3591 ..,....er �krlceianrfrnnn rnm SiTBDIV. & LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 DdODEL: 4EBB "1828-CALI" GARAGE SWING?: RIGHT PAGE: WALL ASSEMBLY DETAILS 160 MPH EXP. Cl ARCHITECT STATE OF FLORIDA MAR 19 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 03 17 21 DATE: / / SCALE: 1/4"=1'-0" SHEET ®l® A d - --- -- - 2x6 SUB -BAND %1 W/1"x4` NOTCH END, WRAPPED IN �LI PEEL 4 STICK METAL FASCIA WRAP N 1" DRIP EDGE �� /8 -1/5" TEXTURED I \ \\ FINISH WOOD I 2X6 SUB BAND 1/2" TEXTURED \ b' FINISH 10 GMU \\ METAL FASCIA \ WRAP Y8FROM \\ f=" O I �l STUCCO, 1" FROM \ WOOD WALL WALL EXTERIOR \ (FRAME OR CMU) \ NOTE: NOTCH FOR 2X(o \ ROOF KICK OUT REMOVED � SUB BAND ONLY \ FOR CLARITY \�� \ ROOF DECK (BEYOND) DRIP EDGE, 1" OFF WALL XNOT INTO STUCCO) 1-1/5" TEXTURED FINISH lw WOOD, 1/2II TEXTURED FINISH 6 CMU 2x6 SUB -BAND W/1"x4" NOTCH Q END, WRAPPED IN PEEL 4 STICK @ELEVATION- =1 A\I A METAL FASCIA WRAP 1" OFF WOOD WALL. SUB BAND 2" OFF WOOD WALL 1/8' TEXTURED FINISH a WOOD, 1/2' TEXTURED FINISH m CMU METAL. LATH WOOD SHEATHING OR CMU WRB LAYER °I, STUCCO WRAP (FRAME ONLY) WRI5 LAYER 02, FORTIRIBER BUILDING PAPER (FRAME ONLY) ROOFING CEMENT DRIP EDGE METAL KICK OUT NOTE: IF ZIP SHEATHING PLEASE SEE MAr PROCEDURES PRE-ENG'D TRUSS TO BE CUT WALL LINE TO AVOID CONTACT W/TEXTURED FINISH 2 "x4 "x4' - o'I SCABBED TO TRUSS W/12d NAILS 6"-S" O.C. MAX. 2x SUB -BAND W/lY"x4" NOTCH w END METAL FASCIA WRAP DRIP EDGE EXTERIOR WALL (FRAME OR CMU) SUB BAND DETAIL @ WALL SUB BAND DETAIL (4WALL W/KICK—OUT FRAME OR CMU FELT PAPER DRIP EDGE (REFERENCE POINT ONLY, FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. Y4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/12"x4" NOTCH 6 END, WRAPPED IN PEEL 4 STICK *ROOF CEMENT 6 ROOF EDGE OMITTED FOR CLARITY GgRevieweo i, t Coi a a Unimversal t Sciences FRAME OR CMU WALL KICK -OUT FLASHING FELT PAPER DRIP EDGE (REFERENCE POINT ONLY FOR WALL OFF SET OF COMPONENTS) METAL FLASHING, WRAPPED MIN. )/4" ABOVE BOTTOM OF DRIP EDGE 2x SUB -BAND W/V22"x4" NOTCH END, WRAPPED IN PEEL 8 STICK *ROOF CEMENT a ROOF EDGE OMITTED FOR CLARITY 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www. a b d es i g ngrou p. co m AA #: 0003325 J SUBDIV. 8c LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT 04321.200 027R1 MODEL 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: WALL ASSEMBLY DETAILS: SUB —BAND 160 MPH EXP. C ARCHrrECT: STATE OF FLORIDA MAR 19 2321 MICHAEL C. ANDERSON AR NO 17305 rL%Lx4 a 2117 DATE: 03 / / 1 SCALE: 1/4"=1'-0"' SHE�E�Tr �/ d A I win -. F I II 9 3 8" 12'-4" ,-4" 7'-4" q 17,_4„ C , I 10,4' 10'-b„ FM-12X1216'-0„ 3,_4„ N �i 4" CONC. r r o, SLAB Izo N a� NI ILL O a LL I 3 .:3 1/2" 1.1. FM 12X18 SLAB 1 1/2" i i I � I r I I < O U O a 'I - r I— 1 f1 C I I 0101, TOP O F - � I SLAB ' M co x N u- LLI II q I r I I IN �LL m i I I „ 5,.0,, 15,_8„ 19,-0 C. 1 `%4" PVC CHASE - TE-1 4 CONC. I e SL AB -5 1/2" ,I 4" ESLAB 2,_8„17.8 " 3'-0"` cp o I - I. io co w r X �I - w a LL .I I 1 EXTEND SLAB 1 1/2" 2 L1 4 CONIC00 . F-12)C18 ro 1.1 Ur w x SLAB ¢ X u- a N I IN I w J LL L I I +-3 1/2" LLI I 5 !2" 3' 5„ 5 1/2" " LL 4:7 1/2" 100 1.1 1.1 FMC-12X18 FMC-12X18 IV 2X1 _ F FM 1 8 1 FMT2X8 —J L 7 4 4 1.1 1.1 10_ 3_ 16'-0 2'- 8" 2' 2 8 10,, I 141-0„ 4'-4" A 21'-4„ <r co I I 5, FOUNDATION PLAN SCALE: 1/4" = V-0" FOUNDATION NOTES 1. SEE SLAB SCHEDULE FOR SLAB REQUIREMENTS. SEE GENERAL NOTES FOR COMPACTING REQUIREMENTS" 2. TOP OF FINISHED SLAB SHALL BE+-0'-0". 3, COLUMN AND FOOTING CENTERLINES, SHALL COINCIDE UNLESS DIMENSIONED OTHERWISE. 4. REFERENCE ELEVATION +44". SEE SURVEY PLOT FOR NAVD. 5. PROVIDE A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT SHOULD BE IN ACCORDANCE WITH THE RULES AND LAWS AS ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES. 6. PROVIDE ISOLATION JOINTS BETWEEN INTERIOR AND EXTERIOR SLABS ON GRADE: PROVIDE 1/2" FELT PAPER AT THE JOINT. 7, COORDINATE SLAB ELEVATIONS, STEPS, AND SLOPES WITH ARCHITECTURAL DRAWINGS. 8. SEE ARCHITECTURAL DRAWINGS FOR THE ORIENTATION OF THE BUILDING, 9. WINDOWS, DOORS AND ROUGH OPENINGS ARE TO BE COORDINATED WITH THE WINDOW/DOOR TYPES AND LOCATIONS NOTED ON THE ARCHITECTURAL DRAWINGS AND WITH THE MANUFACTURES SPECIFICATIONS. 10. SEE ARCHITECTURAL DRAWINGS FOR WALKWAY SLAB LAYOUT, 11:'-UINDICATES #5 BAR, OINDICATES #6 BAR,■INDICATES #7 BAR VERTICAL REINFORCING BAR IN CELLS FILLED WITH GROUT. ENDS OF REINF. BARS SHALL BE HOOKED INTO FOUNDATION BOND BEAM OR TIE BEAMS WITH AN ACI STANDARD 900 HOOK. BARS SHALL BE PLACED AS SHOWN IN HE PLANS. 12. SPLICES IN REINFORCING BARS SHALL NOT BE LESS THEN 48 BAR DIAMETERS (#5 = 30 #6 =36"), AND REINFORCING SHALL BE CONTINUOUS. 13. RATIONAL ANALYSIS WAS PERFORMED TO DETERMINE SIZE AND STEEL REINFORCING FOR ALL FOUNDATIONS. DESIGNED WAS BASED ON ALL ALLOWABLE SOIL BEARING CAPACITY OF 2,000 PSF. TRANSFER REINFORCING (TOP STEEL) HAS BEEN DELETED UNLESS NOTED OTHERWISE. 14. VERTICAL REINFORCING IN CMU SHALL BE #5'S AS SHOWN ON THIS PLAN, UNLESS OTHERWISE NOTED IN THE PLAN. ONE REINFORCING BAR SHALL BE: A) IN ALL WALL INTERSECTIONS B) CHANGES IN ELEVATION C) EACH SIDE OF ALL OPENINGS D) ALL CORNERS 15. STRUCTURAL DESIGN IS IN ACCORDANCE WITH TMS 402/602 16, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES AND THE COMMENTARY. CONSTRUCTION SHALL BE IN ACCORDANCE WITH TMS 402/602-16, USING F m = 2,000 PSI, TYPE "M" OR" S" MORTAR, ASTM C476 GROUT (3000 PSI), UNITS LAID IN RUNNING BOND. 16. WIRE WELDED MESH LOCATED IN THE MIDDLE TO UPPER 3 OF SLAB SUPPORTED S-0" O/C MAX. SEE PLAN FOR WWM SIZE. INSPECTOR NOTE: 1. STRUCTURE WAS DESIGNED BASED ON THE 2020 FLORIDA RESIDENTIAL BUILDING CODE, RESIDENTIAL, 7th EDITION SLAB SCHEDULE SLAB THICKNESS REINF. REMARKS 6x6 W1 4XW1.4OVER GENERAL 3 1/2 6 MIL VAPOR COMPACTED FILL BARRIER FOOTING S DCCD� O' OGEG EACH WAY. R-FOUNDATION, PROVIDE CORNER BARS, SAME SIZE QUANBARS MARK WIDTH LENGTH THICKNESS BOTTOM REINF. TOP REINF. SHORT LONG T.O.F. TE-1 8" SEE PLAN 101, - (2) #5's (+)0"-0" FM-12x12 12" CONTINUOUS 12" - (2) #5's + 0 -0" FM-12x18 12" CONTINUOUS 18" - (2) #5's - (+)0 -0" FM-16x18 16" CONTINUOUS 18" - (2) #5's - (+)0"-0" FMC-12x18 12" CONTINUOUS 18" - (2) #5's VARIES F-24x24 24" 24" 12" s s (-)p 4" SECURE STRAP TO A/C SIMPS❑N WB CONC. W! UNIT ROLL STRAP OR (2)AP EQUAL @ EACH T AP -CONS CORNER OF FIT UNIT CONC, SECURE STRAP TO SLAB UNITS W/ (2) #Bxl 1/4 SHT MTL SCREWS A/C CONNECTION TO PAD DETAIL Reviewed fur Code Unive urnpliance rsal Engineering sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 0 CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 MODEL: 4EBB "1828-CALI" " ARAGPE s11117N :: RIGHT PAGE: FOUNDATION PLAN 160 MPH UP. ARCHr ECT STATE OF FLORIDA MAR 1- 9 2021 MIC HAEL C. ANDERSON AR NO 17305 M:0317 21 - / / SCALE: 1/4"=1'-0" SHEET n s i 30„ MIN. EACH WAY MONOLITHIC FOOTING Z Z STEEL REINFORCING IN GROUTED -- — STEEL REINFORCING IN GROUTED Q d CELL SEE PLAN FOR SIZE AND CELL SEE PLAN FOR SIZE AND m > I SPACING REQUIREMENTS d SPACING REQUIREMENTS m Q v m m w -n - � r I m U OD aEE w r FM co a Cn O Q 8 CMU WALL CORNER BARS, SAME SIZE AS LARGER BAR I " m cn 0 _ Z CID 8" CMU WALL - z _. 1N FOUNDATION WITH 30" LEG EACH I M +- 0'-0" WAY AT ALL CHANGES IN DIRECTIONS I o C' + 0.41 SO THAT THE STEEL REINF. IS CONTINUOUS I TOP OF SLAB TOP OF SLAB aEE °" MATCH AMOUNT OF CONTINUOUS BARS I d VARIES : 01SCHEDULE LL S EXT. PORCH SLAB 4" CHAMFER (I -STORY). W/ 1/2" ISOLATION 6" CHAMFER (2-STORY) JOINT WHERE • ( SEE SCHEDULE APPLICABLE) Z FOR WxD, BAR SIZE iv AND BAR QUANTITY BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" RA E NTINUOUS STEEL MONOLITHIC SEE SLAB SCHEDULE TOP OF GA G CO EXT. PORCH SLAB L 4" CHAMFER (1-STORY) FOOTING REINFORCEMENT SEE SCHEDULE W/ 1/2" ISOLATION f 6" CHAMFER (2-STORY) JOINT (WHERE f ° i SiE SCHEDULE WHEN TRANSITIONS ARE MADE FROM FOUNDATIONS HAVING APPLICABLE) Z FOR WxD, BAR SIZE DIFFERENT NUMBER OF CONTINUOUS BARS PROVIDE THE LEAST s` AND BAR QUANTITY NUMBER OF BARS (ie. 2 TO 3, PROVIDE 2 BARS), UNO CV EXTERIOR MONO -FOOTING GA EXTERIOR MONO —FOOTING MONOLITHIC FOUNDATION ri cZrIo1 F.'VA"-,'_n" (2 RAG E SCALE:3/4"=V-0" ��� CORNER BARS DETAIL MMIA 2"CAPPED GALVANIZED PIPE W/FLANGE @ BASE o M i SECURE FLANGE TO SLAB W/(4) 1/4" X 2 1/4" TAPCgNS @ w NEW REINF. BAR A SECURED W/2-PART EPDXY. MIN. EMBED 4 8", LINO jp FOLLOW ALL MANE 4 SPECIFICATIONS FOR I USE AND m co PREPARATION OF a HOLE. m W Q) QQ0 P 4" CHAMFER (1-STORY) 6" CHAMFER (2-STORY) ALE:3/4"-,'-o" ADDING BAR TO �� MONOLITHIC FOUNDATION LAP P PLATE A MIN. OF 48" AND N W/ 16d COMMON NAILS, 2- WS, 4" O/C BTM. VERIFY HEIGHT LAP TO OC R OVER STUD OF WALL W/ PLAN 2x4 OR 2x6 WOO EARING PROVIDE BLOCK G WALL W/ SYP No 2 UDS SEE PLANS FOR SPACING. INGLE BTM. PLATE TO BE PT. RE B . PLATE TO PROVIDE DBL. TOP PLAT LA d MASONRY NAIL TAGGERED: IONAL METAL NECTORS NOT QUIRE WHEN NO UPLIFT IS PRESENT. SEE SLAB SCHEDULE +- p -0" Z TOP OF SLAB co F ® SEE SCHEDULE OR WxD, BAR SIZE D BAR QUANTITY INT IOR FOUNDATION OD WALL 9 SCALE:3/4"=V-0" (NO LIFT) d a Q r m w w U J cf: CO CL 0 � STEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND SPACING REQUIREMENTS 8" CMU TOP OF SLAB Z REXTERI EE SLAB SCHEDULE 1ATED" COLUMN PAD cl °TERED UNDER WALL AND RED MONOLITHICALLY WITH — — fNDATION AND SLAB ° LE SIZE TY MRIO MONO- 1 OOTING AND COL. P AP TOP PLATE A MIN. OF 48" A NAIL W/ 16d COMMON NAIL 2-ROWS, 4" O/C BTM. LAP T CCUR OVER STUD 2x4 OR 2x6 D BEARING WALL W/ SYP No 2 STUDS SEE P S FOR SPACING. SINGLE BT PLATE TO BE PT. PROVIDE DBL. OP PLATE SIMPSON SPH4 OR SPH6 BTM AND TOP PLATE t ANCHORS W/ 10d x 1 112" COMMON NAILS FILL ALL HOLES, DO NOT USE 10d w x3 Ir Q +- 0'-0" TOP OF SLAB SCALE: 3/4"=V-0" — VERIFY HEIGHT OF WALL W/ PLAN �PROVIDE BLO ING 1 t�HPLATE TO SLAB W/ "x DGE ANCHOR W/ 2 WR SET IN HIGH STRENGTH XY 5.1 /2" EMBED. MIN. @ 16" OC EE SLAB SCHEDULE f f EQ: EQ. SEE SCH ULE FOR WxD, BA IZE -- AND BAR QUANT INTERIOR CURB FOUNDATION WOOD WA SCALE :3/4"=V-0" (1A1/ UPLI POURED LINTEL CONT. (TYP.) 8" CMU FILLED CELL (TYP.) 2X WALL FRAMING 1/2" DIA. SIMPSON STB2 BOLTS 5" MINIMUM EMBEDMENT INTO GROUTED CELL, 4" FROM ENDS AND 16" O.C. VERTICALLY MAX INTERIOR FRAME BRIG WALL TO 11 .BLOCK WALL CONNECTION SCALE: 3/4"=1'-0" FOR NRY SET EV: RECESS AROUND GARAGE DOOR OPENING LAP TOP PLATE A MIN. OF 48" AND NAIL Wr 16d COMMON NAILS, 2-ROWS. 4" O/C BTM. LAP TO OCCUR OVER STUD 2x4 OR 2x6 WOOD BEARING - WALL W/ SYP No 2 STUDS SEE PLANS FOR SPACING. SINGLE RTM. PLATE TO BE PT. PROVIDE DBL. TOP PLATE + 0 _0" TOP OF SLAB SCALE: 3/4"=V-0" VERIFY HEIGHT OF WALL W/ PLAN PROVIDE BLOCKING SECURE BT. PLATE TO SLAB W/10d MASONRY NAIL 16" O/C STAGGERED: / ADDITIONAL METAL CONNECTORS NOT REQUIRED WHEN NO w UPLIFT IS PRESENT. rSEE SLAB SCHEDULE IQ ° z f a " EQ. EQ. SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY INTERIOR CURB FOUNDATION WOOD WALL SCALE: 3/4"=V-0" (NO UPLIFT) EgReviewed for Code compliance Univer sal Engineering Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321$02-3591 www.abdesigngrou[P..com AA #: 0003325 Iq 5� CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 MODEL: 4EBB "1828—CALI' GARAGE SWING: RIGHT PAGE: is A DETAILS 1,46_160 MPH EXF ARCHrrECT. STATE OF FLORIDA MAR 19-2021 MICHAE:IL. C. ANDERSOI H NO, 17105 Pl%a�T6� a> DATE: 03/17 /21 SCALE: 1/4"=1'-0" SHEET sie1Aj 5. 1 a w Nk— IY I� n C] 7 v ita ib Ili"v 0 r ilk (V tl0 Nk U I 29'-0" 27'-0„ - - -- — 25'-10" 19' 0" 17'-8" T____ ___ 14'-0" 10'-0 Til 11.1I,l I. 1.1 7 (V T L o E 3'_6h 2'-4"- 10'-6" — DOWEL PLAN SCALE: 1/4" = 1'-0" 19'-01, -- I OP O co 0 M OP N 0 N O N in 0 a In L [•I I 0 N rn Reviewed foe G,n� Compli a.,cl- Universal En !.i r,,,y Sciences HWY A1A, SUITI \N HARBOUR BE FLORIDA 32937 H: 321-802-359 i.abdesigngroup. AA #: 0003325 %a } i r SUBDIV. & L.OT. CREEKSIDE PHASE 2 LOT #27 PROJECT* 04321.200 027R1 MODEX: 4EBB "1828—CALI" ,r GARAGE SWING RIGHT PAGE:r." DOWEL PLAN Ff 160 MPH EXP. C ARCHnECT: STATE F FLORIDA MAR 19 2921 MICHAEL C. ANDERSON AR NO 17305 DA ET 03/17/21 SCALE: 1/4"=1'- 0" SHEET S1. 2 TIE VERTICAL REBAR TO HORIZONTAL REBAR W/ 10" HOOK GROUTED BOND BEAM — VARIES PER ELEV. zj t a v N a i al a p7 CLEAN OUT REQUIRED FOR INSPECTION L L OD O o it m 0'-0" FIN. FLR. TIE ERTICAL REBAR a TO HORIZONTAL REBAR W/ 10" HOOK a BAR SIZE 48 BAR DIA. #3 18" #4 24" #5 30" #6 36" #7 42" HORIZONTAUVERTICA 1 REINFORCING SCALE. 3/4"=l'-0" z S — TEEL REINFORCING IN GROUTED CELL SEE PLAN FOR SIZE AND } SPACING REQUIREMENTS � H dw ao co t> it Z 8" CMU WALL O to 0 co SEE SLAB SCHEDULE EXT. PORGH SLAB 4' CHAMFER (1-STORY) W/ 1/2" IS 6"'CHAMFER (2-STORY) JOINT (WHERE i APPLICABLE) Z MATCH STEEL g REINFORCEMENT 6"PVC CHASE w PERSCHEDULE THRU FOOTING SEE SCHEDULE FOR WxD, BAR SIZE AND BAR QUANTITY PVC C THRU O M UL--4z� —L f a as 6" PVC CHASE THRU FOOTING MATCH STEEL REINFORCEMENT PER SCHEDULE A E FO TING SCALE: 3/4"=1'-0 CMU UNIT DIMENSIONS 7 ( ARE NOMINAL SIZES MASONRY SYMBOLS 3 SCALE:3/4"=V-0" Reviewe en c'nr., Unive SamF-r,yrrr Sciences. econ� 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200/027R1 r 4EBB r "1828 CALI" ARAGE SWING: � RIGHT i3p PAGE: I DETAILS i I, h4x ARCHITECT STATE OF FLORIDA 1 MAq 19 2021 I �1 MICHAEL C. ANDERSON AR NO 17305 ji�)DATE: 03/17/21 SCALE: 1/4"=1r-0" x, SHEET r,, J ..,1�4� FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE I CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9) 10d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 1 Od x 1 1/2" HDG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 W/ 1 Od x 1 1/2" HDG NAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING IS TO BE PER FASTENER SCHEDULE. 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED ATTOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL FINALTRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X•ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177' ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. 13. ALL ELEVATIONS ARE REFERENCED FROM 0'-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. BEAM SCHEDULE INDICATES OPENING BELOW / T.O.B. = TOP OF BEAM / B.O.L. = BOTTOM OF LINTEL / T.O.A. = TOP OF ARCH / T.O.S = TOP F SLAB ABBREVIATIONS E.E. = EACH END, O/ = ON CENTER; F.E.S. = FROM EACH SUPPORT; T.O. = THROUGHOUT MARK DESCRIPTION (psi) WSIZH' ZE REINFORCEMENT STIRRUPS REMARKS BTM. TOP MID SIZE SPACING 881 MASONRY 3000 PX8 — (1) #5 — N/A' — GROUTED SOLID SEE SHEET S2.2A FOR SAFE LOAD TABLES a ,® 8F16-1T/OM/0B � ♦ 1 1 � ♦ 1 GT 1 CDDOI ` ♦ 0 1 o ♦ ♦ 0 1 1 yLL 1 i co 1 co I re------ --- �0 1co ----- ----71 1 ♦ 8F16-1T/0M/0B _ 1 ♦ 8F16-1T/0M/0B 2 8F24- ♦♦ ♦ 1 1 ♦ % 11 T/OM/OB ♦ ♦ 1 1 I♦ ♦ ♦ ♦♦♦ 10 1 � w ♦ 1 l ♦ GT ♦ 1 1 ♦ ♦ 1 1 ``% ♦♦♦ 1 1 ° ♦ 1 C) co 1co 1 � ♦ 1 Y 1 1 I 1 1 1 1 1 1 I 1 1 I 1 I 1 1 I 1 1 1 1 1 I 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 1 lC) 1 0l to Z 1 �1 1 7 2.1 1 m 1 17 L1 1� 1 1 I� 1 1 1 I 1 1 1 1 1 UNO, PROVIDE BB1 WHERE 1 1 1 ROOF TRUSSES BEAR, TOP 1 1 OF WALL EL. 8'-8", UNO. 1 1 1 � 1 1 I 1 1 I 1 I 1-- 1 1 ♦ ° 1 1 ♦ � 1 1 ♦ 1 ♦ 8RF6- I� 1 ♦♦ 1T/OM/OB I 1 1 1 5'-4„ ♦ 1 1 ♦ 1 1 1 ♦ ♦♦ 1 1 1 1 I 1,°° i ♦♦♦ ; 1 1 °° 8RF6-1T/0M/0B ♦♦ 1 8F16-1T/0M/0B ♦ 1 1 _ - .ram—T------------1---------...1 L-----------------.-------�—J 8F24 MIN.-1T/0M/1B 17-4 BTM. OF LINTEL @ T-0" ABOVE FINISHED GARAGE SLAB LIFT BEAM PLAN SCALE: 1/4" = V-0" 0 r` 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 REEKSIDE PHASE2 LOT #27 PROJECT# I 04321.200 027R1 MODEL 4EBB "1828—CALI" i•ARAGE SWING: RIGHT Reviewed tot Code PAGE: Compliance universalEnnee,,ny Sciences LIFT BEAM Sciencees PLAN AND NOTES Ll0 �IPH EXP. C ARCHfFECT. TE F FLORIDA MAR 19 2021 MICHAEL C. ANDERSON AR NO 17305 03 17 21' �ArE: / / SCAUE: 1/4 =1'-0" SHEET S 2 a a R R H #5 CORNER BA W/ 30" LAP FOR EACH COURSE OF BOND BEAM VERTICAL REBAR W/ 10" HOOK 11 { 30" TYPICAL #5 BAR IN BOND BEAM CORNER r--"' REINFORCING OF BOND BEAM SCALE: 3/4'=V-0" NOTES TO THE INSPECTOR/CONTRACTOR TYP.8"x8" 1. PLACE LINTEL ACROSS TOP OF OPENING. BOND BEAM 1#5 2. IF BOTTOM STEEL IS REQUIRED PLACE #5 BAR IN LINTEL. 3. PLACE MASONRY UNITS AS TO ACHIEVE THE BEARING UIRED �OF�\���� REINFORCING (L2) 4 THE LAST COURSE WILL BE A BOND BREAM WITH (1) 5 BAR CONTINUOUS ROUND NGPLACE STEEL HEIGHT. � AS DEPICTED HEREIN. STRUCTURE. A DOUBLE BOND BEAM MAY BE SPECIFIED SO THAT THEN THE LAST 1#5 TWO COURSES ARE BOND BEAMS WITH A #5 BAR IN EACH COURSE. TYP. 8"x16" co P 5. SHOULD THE DOUBLE BOND BEAM COINCIDE WITH A LINTEL THE BOTTOM BOND BEAM p COURSE OF BOND BEAM IS OMITTED AND A LINTEL IS PLACED THE STEEL REINFORCING FOR THE BOTTOM BOND BEAM IS TO BE CONTINUOUS THROUGH THE 1#5 TOP OF THE LINTEL. 6. UNO COMPOSITE MASONRY BEAM IS TO BE NOT LESS THAN 16" DEEP. 8x16 DBL. BOND _ TOBP OF BEAM W/ (1) #5 BAR BOND BEAM Y— • EACH COURSE p YNp 8x8 BOND BEAM TOP OF • Q�G� F =FILLED W/GROUT W/ (1) #5 BAR BOND BEAM ��p U =UNFILLED GROUT SOLID FROM TOP NOMINAL LINTEL TO TOP OF BOND OF OPENING �j WIDTH # OF #5'S, IN 2ND BOND BEAM, IF FILLED LINTEL. i �` i BEAM COURSE - SEE NOTE 5 -- 05� �0 ��1 V-1 T/ I M/OB LINTEL W/A(1)#5BAR R(L2)E HOE GIHTL # OF #5'S, TOP LENGTH OF BAR = WIDTH OF MASONRY BOND BEAM COURSE OPENING-2'' BEAM DESIGNATION IT IS THIS ENGINEER'S INTENT OR /-i1Vl DESIGNATION V/'1 I V THAT XFXX - 1T/1 M/OB INDICATES A DOUBLE BOND'. BEAM /#OF #5'S, BOTTOM Bx8 PRE -CAST CONCRETE SCALE: 3/4"=1'-0" AND XFXX - 1T/OM/OB INDICATESA SINGLE BOND BEAM PLACED IN LINTEL LINTEL. W/O STEEL (Ll) REFER IT IS THIS ENGINEER'S INTENT TO PLAN FOR LOCATIONS AND XUXX - 1T/1 M/08 INDICATES'A DOUBLE BOND'. BEAM ABOVE UNFILLED TOP LINTEL OF OPENING 00 AND XUXX - 1T/OM/08 INDICATES'A SINGLE BOND BEAM ABOVE UNFILLED LINTEL PRECAST HEADER(MIN) w WINDC PRE -CAST WINDOW SILL PE TYPICAL MASONRY WINDOW SILL CONSTRUCTION 2x4 (MIN 2 X 3) 1-3/16 APCON OR DRIVE PIN (MIN S K SIZE.145 MIN HEAD SIZE . MIN EMBEDMENT 1 1/4") 8" F EACH END AND 18" O.C. MA . IN 1-1/4" EMBEDMENT 2x6 (MIN 2 X 3) 2-3/16 TA ON OR DRIVE PIN (MIN SHANK SIZE.145 MIN HEAD SIZE .300 MIN EMBEDMENT 1 1/4') 8" FROM EACH END AND 18" O.C. MAX. MIN 1-1/4" EMBEDMENT 2x8 (MIN 2X 3) 23/16 TAPCON OR DRIVE PI LIQ SHANK SIZE.145 IN A SIZE .300 MINE T 1/4") 8" FROM EACH ND ND 18" O.C. MAX. MIN 1- .4'/ EMBEDMENT SINGLE #5 CORNER BAR, 30x3O TURNED UP OR TURNED DOWN INTO FILLED CELL 2X4 SOLID BLOCKIN SECURE TO SHEATHING MIN. 2-12d PER BILK. EA. END - 7,16" OSB SHEATHING --CMU WALL ARCHWAY FRAMING DETAIL SCALE: 3/4"=V-0" Reviewed for Cotle cclrr'GF""E Universal. t.:.: gineerin Sciences 9 STEEL REINF. OF BOND. BEAM PROVIDE #5 BAR STEEL REINF. OF EACH SIDE O LEVATION BOND. BEAM CHA E CHANGE IN ELEVATION OF BOND BEAM SCALE: 3/4"= 2194 HWY A1A, SUITE 30J INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 ;a a z r 3UBDIV. & LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT#''' 04321.200 027R1 MODEX • 4EBB "1828-CALI" GARAGE SWING: r,. RIGHT PAGE: _-_. 01 DETAILS 160 MPH EXP. C ARCHITECT,) STATE OF FLORIDA MAR 19° 2021 MICHAEL C. ANDERSON AR NO 17305 DPRINT 03/17/21 SCALE: 1/4"-1'—O" SHEET a S 2 > 1 G "LOTT'S CONCRETE" / "CAST-CRETE" / "QUALITY" SAFE LOAD TABLES SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LATERAL LOADS FOR SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LINTELS SAFE LOAD - POUNDS PER LINEAR FOOT SAFPE LOAD SAFE LOAD - POUNDS PER LINEAR FOOT TYPE LENGTH 8U8 8/8-OB /16-1T/06 /20-lT/06 /24-1T/OB /28-1T/OB /324T/013 TYPE LENGTH 8/8 PLAIN 8/8 SOLID TYPE LENGTH 8/8-1T 8/16-1T 8/20-1T 8/24-1T 8/28-1T 8/32-1T 8/8-1B 8/16-1TOB /20-1T/18 /24-1T/16 /28-1T/1B /32-1T/1B 8/8-2T 8/16-2T 8/20-2T 8/24-2T 8/28-2T 8/32-2T 3'-6" PRECAST 1436 952 3114 4217 5321 6426 7531 3'-6" PRECAST 689 1024 3' 6" PRECAST 1569 3524 4394 5263 6132 7001 2465 6113 6385 7708 9031 10000 1569 3524 4394 5263 6132 7001 4'-0" PRECAST 1065 700 2305 3125 3945 4765 5587 4'-0" PRECAST 514 763 4' 0" PRECAST 1363 3060 3815 4570 5325 6079 1961 6113 7192 6524 7627 8751 1363 3060 3815 4570 5325 6079 4'-6" PRECAST 819 533 1770 2400 3033 3666 4300 4'-6" PRECAST 398 591 4'-6" PRECAST 1207 2582 3375 4043 4711 5379 1625 5743 7547 6752 6541 7565 1207 2707 3375 4043 4711 5379 5'-0" PRECAST 931 1247 1999 2560 3123 3686 4249 5' 4" PRECAST 411 411 5'-4" PRECAST 1016 1806 2374 2944 3513 4084 1319 4460 7196 7342 5780 6259 1016 2276 2838 3399 3961 4084 5'-10" PRECAST 817 1024 1631 2090 2549 3009 3470 5'-10" PRECAST 340 339 5'-10" PRECAST 909 1499 1971 2443 2915 3387 1161 3693 5877 6036 6548 5776 929 2080 2593 3107 3620 4133 6'-6" PRECAST 692 1139 3227 3031 3707 4383 5061 6'-6" PRECAST 410 721 6'-6" PRECAST 835 1201 1578 1955 1 2332 2709 1139 3227 4598 7054 10000 8825 835 1868 2329 2790 3251 3712 7'-6" PRECAST 570 938 2498 2205 2698 3191 3685 7 -6" PRECAST 373 534 7'-6" PRECAST 716 900 1181 1462 1743 2025 938 2498 3408 4864 7067 6472 727 1624 2025 2426 2827 3228 9'-4" PRECAST 428 633 1593 2204 2481 2818 2621 9-4' PRECAST 192 384 9'-4" PRECAST 454 586 767 948 1129 1310 639 1674 2298 3081 4099 4899 572 1318 1643 1969 2164 2519 10'-6" PRECAST 388 487 1247 1767 1 1904 2163 2028 10'-6" PRECAST 151 301 10'-6" PRECAST 356 468 612 755 899 1042 550 1407 1897 2781 3222 3784 504 1180 1472 1763 1710 1989 11'-4" PRECAST 330 544 1312 1742 2252 2868 3630 11'-4" PRECAST 132 417 11'-4" PRECAST 430 406 530 653 777 872 544 1312 1742 2252 2868 3552 466 1042 1372 1643 1470 1710 12'-0" PRECAST 308 507 1210 1596 2048 2586 3191 12'-0" PRECAST 111 370 12'-0" PRECAST 383 366 476 581 698 783 507 1210 1596 2048 2586 3171 440 940 1300 1560 1314 1476 13'-4" PRECAST 270 433 1045 1365 1732 2157 2535 13' 4" PRECAST 82 298 13' 4" PRECAST 308 303 393 484 575 645 414 1045 1365 1732 2316 2605 396 780 1057 1312 1071 1203 14'-0" PRECAST 254 388 978 1272 1606 1988 2279 14'-0" PRECAST 71 293 14'-0" PRECAST 279 278 360 443 526 609 390 s7s 1z72 lsos 1950 23ss 378 717 961 1192 975 1133 14'-8" PRESTRESSED N.R. NR NR NR NR NR NR 14'-8" PRESTRESSED N.R. 283 14'-8" PRESTRESSED 239 422 506 626 746 865 458 1079 1429 1824 2277 2712 246 663 980 - 1237 1474 1715 15'-4" PRESTRESSED N.R. NR NR NR NR NR NR 15'-4" rRESTRESSED N.R. 252 15'-4" PRESTRESSED 224 387 464 574 684 793 412 1014 1340 1703 2118 2513 230 616 908 - 1134 1353 1572 17'-4" PRESTRESSED N.R. NR NR NR NR NR NR 17'-4" PRESTRESSED N.R. 183 17'-4" PRESTRESSED 187 326 365 451 587 680 300 856 1121 1413 1739 2047 192 506 720 501 1135 1312 19'4" PRESTRESSED N.R. NR NR NR NR NR NR 19.-4" PRESTRESSED N.R. 148 19'-4" PRESTRESSED 162 266 348 430 513 595 235 736 959 1200 1467 1716 166 429 623 803 950 1098 211-4" PRESTRESSED N.R. NR NR NR NR NR NR 21'41 PRESTRESSED N.R. 125 21'-4" PRESTRESSED 142 219 308 381 454 527 180 598 833 1038 1168 1458 142 373 537 690 816 943 22'-0" PRESTRESSED N.R. NR NR NR NR NR NR 22'-0" PRESTRESSED N.R. 116 22'-0" PRESTRESSED 137 226 290 359 428 497 165 550 784 992 1203 1381 137 358 513 659 779 900 24'-0" PRESTRESSED N.R. NR NR NR NR NR NR 24'-0" PRESTRESSED N.R. 91 24'-0" PRESTRESSED 124 174 245 302 360 418 129 450 654 824 1014 1147 124 319 455 581 687 793 - ALL VALUES TAKEN AS THE LESSER FROM "SAFE LOAD TABLES" BY QUALITY 2018 EDITION, LOTT'S MAY 2015 EDITION - PRECAST PRODUCTS BY OTHERS TO MEET OR EXCEED VALUES STATED ABOVE AND CASTCRETE MAY 2015 EDITION. - ALL PRECAST PRODUCTS ARE TO BE INSTALLED PER MANUFACTURES SPECIFICATIONS - PROVIDE MINIMUM 4" OF BEARING PAST EACH SIDE OF WINDOW OPENING PRODUCT CONTROL NOTICE OF ACCEPTANCE F.E.C.P. CORPORATION-CASTE-CRETE DIVISION ACCEPTANCE #: 19-0130.13 91 Reviewed for Coc Compliance Universal Engineer Sciences 2194 HWY AlA, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802-3591 www.abdesigngroup.com AA #: 0003325 o SUBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT* 04321.200 027R1 MODEL: 4EBB "1828-CALI" GwARAGE SWING: RIGHT PAGE: SAFE LOAD TABLES I60 MPH EXP. C ARCHITECT STATE OF FLORIDA MAR 19 2021 MICHAEL C. ANDERSON AR NO 17305 DATE:03/17/21 1 SCALE. 1/4"=1' - 0" SHEET Ste 2A HIS FRAMING NOTES: 1. U.N.O. ALL STRAPS FOR ROOF TRUSSES TO BE ' CONCRETE TO WOOD ROOF: SIMPSON HETA16 W/ (9)110d x 1 1/2" HDG NAILS. CONCRETE TO WOOD FLOOR: SIMPSON LTA2 W/ (8) 10d x 1 1/2"'HDG NAILS, WOOD TO WOOD: SIMPSON H10A OR LGT2 W/ 10d x 1 1/2" HDGNAILS, FILL ALL HOLES. 2. ALL PLYWOOD FOR WALL AND ROOF SHEATHING J8 TO BE PER FASTENER SCHEDULE. I 3. ALL PLYWOOD FOR FLOOR SHEATHING SHALL BE PER FASTER SCHEDULE MEETING THE REQUIREMENTS OF AFG-01 AND APPLIED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. 4. ALL NAILS FOR TRUSS TO BEAM AND TRUSS TO TRUSS METAL CONNECTORS ARE TO BE GALVANIZED. 1 5. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE, , CONNECTERS ARE TO BE GALVANIZED. 6. LINTELS AND MASONRY BEAMS WERE DESIGNED BASED ON CAST-CRETE CONCRETE LINTELS. 7. BOTTOM OF LINTELS ARE TO BE PLACED AT TOP OF WINDOW, DOOR AND CLEAR SPAN OPENINGS. 8. LINTELS SHALL HAVE 4" NOMINAL BEARING (4"). I 9. THE TRUSS FRAMING SHOWN IS SCHEMATIC IN NATURE. HOWEVER THE SUPPORTING STRUCTURE HAS BEEN DESIGNED UNDER THE ASSUMPTION THE FRAMING SCHEME SHOWN WILL CLOSELY PARALLEL) FINAL TRUSS DESIGNERS LAYOUT. SUBMIT FINAL TRUSS DRAWINGS FOR THE ENGINEER'S REVIEW AND APPROVAL. 10. PLACE 2x4 PT TO ALIGN WITH TOP AND BOTTOM CHORDS OF ROOF TRUSSES SECURE 2x MEMBERS TO WALL WITH HILTI X-ZF, POWDER ACCTUATED FASTENER, ZF 72 P8S36, .177 ° x 2 7/8" LONG, WITH WASHER @ 16" O.C. 11. TRUSS REACTIONS AND UPLIFTS SHOWN ARE THE SAME ON EACH END UNLESS OTHERWISE SHOWN DIFFERENT. 12. WOOD BEARING WALLS AND HEADERS HAVE BEEN DESIGNED BASED ON RATIONAL ANALYSIS. I 13, ALL ELEVATIONS ARE REFERENCED FROM 9-0", FINISH FLOOR. UNLESS NOTED OTHERWISE. 14. BOTTOM CHORD BRACING, DIAGONAL BRACING AND GABLE END BRACING SHOWN ON THE FRAMING PLANS AND DETAIL ARE DRAWN AS A DIAGRAMMATIC PURPOSES FOR MINIMUM SPANS AND MAXIMUM SPACING. THESE DRAWINGS ARE INTENDED AS A GUIDELINE FOR CONSTRUCTION AND 610 NOT NECESSARILY REFLECT ALL ACTUAL CONDITIONS THAT MAY ARISE IN! THE FIELD. FIELD IN IJA R M WITHIN W/2X6 1 CHORD (_.TRUSSES Wi2X4 BOTTOM CHORD CONSTRUCTION SHOULD CLOSELY PARALLEL THE BRAC G G A S 2x4 SCAB NAIL D TO \- THESE MINIMUM AND MAXIMUM TOLERANCES. ADJUSTMENTS IN THE FIELD ARE TRUSS BOTTO DIAGONAL ACCEPTABLE FOR FIELD CONDITIONS SUCH AS INTERFERENCES WITH TRUSS END JACK CHORD W/MIN (14 10J� BRACING/BOTTOM WEBBING, SHEETING ETC. IN SITUATIONS WHERE THE DIAGRAMS LOCATION AND WHERE APPLICABLE NAILS FOR EA H jI"CHORD BRACING ACTUAL TRUSS WEBBING CONDITIONS CONFLICT, THE (ICONTRACTOR SHALL PLACE CHORD CONN CTION THE DIAGONAL BRAE ADJACENT TO THE TRUSS WEB A CONDITIONS ALLOW. A DISSIMILAR BOTTOM CHORD BRACING @ END TRUSS MANUFACTURER / ENGINEER NOTES: 1. ROOF GIRDERS W/ UPLIFT IN EXCESS OF 2,500 LBS SHALL BE FABRICATED W/ A 2x6 BTM. CHORD (MIN.) 2. COORDINATE ANY TRAY/COFFERED CEILINGS, AND ATTIC ACCESS WITH THE ARCHITECTURAL PLANS TRAYS AND COFFERS ARE NOT SHOWN ON THIS PLAN IN ORDER TO AVOID CONFUSION IND MISTAKE 3. TRUSS COMPANY / ENGINEER IS RESPONSIBLE FOR ALL TRUSS TO TRUSS CONNECTIONS. I 4. AVOID PLACING A TRUSS PERPENDICULAR TO ASTEELI COLUMN.. MAINTAIN AT LEAST 8" FROM THE CENTER OF THE COLUMN. ---- TRUSSES W/2X4 GIRDER/TRUSS TRUSSES W/2X4 BOTTOM CHORD IOR X6 BOTTOM CHORD BOTTOM CHORD DIAGONAL 2x4 SCAB NAILED TO IAGONAL DIBRACING/BOTTOM BRACING/BOTTOM TRUSS BOTTOM CHOR CHORD BRACING W/MIN (4) 10d NAILS CHORD BRACING FOR EACH CHORD CONNECTION DISSIMILAR BOTTOM CHORD BRACING ® MID RUN B CONN ECFOR SCHED DUE - CUN TULIYAIF 01/}]%ID20 AA Tek USP SIMPSON RTek HER SIMPSON DES UPLIFT GRAVITY DES UPLIFT GAAVRY FASTENER FASTENER ' HTA 1618 1'A, META-16 Hill 18130d x 11/2'•1- PLY,(]) 16d 2 PLY, EMBED4" (8)HBO x 1121-PLY,(6) 3M I�ELY, UYMMD' pi ITA 1618 24'd0 (2)MET116 ROD (12j 10d X J 11VIlPLY, EMBED4" (10)10d al 1/2"1 PLY, EMBED4" HTA 16 IS. HRA-16 1010 (1Df... X11/2"( B)1fitl 2�PLY, EMBEDd" (9)100 X12/2"1-PLY, IS)HIM 2-PUN EMBED4" HTA 20 38]0 HEFA-20 1010 11 Uf 10tl X11/T' 811Ed 2-PLY EMBEOP' RE)Rid X13/2 J-PLY. JR 111HUS, EMBED4" {2 XTA 20 2430 2)HfTA'2B SIMS 112f 10tl I11/2" FIFTY EMBED 4" (10)10d.X 1112'1-0LY, EMBED4" 2SX1 OLD FILL 2-PI,f BED4 T (12116dI PLY EMOfD4 Z LUGT'2 1., 1112 1585 ON(5)1/4'X 3" Wedge I Anch IN, WOOD(16)LIE (]) 1/4:'%21/4- TRIED, WOOD (16) 16d a LUGT3 3380 LGT3 S., 3400 IWXC(4)3/B"% Wetlge.B011«An[M1ors WUDD(l E)WS25. (11)IRS 1/4 x3 TO GIRDER, N) EREI I lI1PN H010WALL <1 OHip}p 2130 OETAL20 2480 (1%20tlx11/2, PLYALTERNATf USE 0i2 HTA-20 ACCEPTABLE S) 18 10d X 1121 PLYALTERNATE USE OF HETA20ACCF 1 ) /. (1 ABLE MVGT35r .3945 MGT« 3965 (1)SIR "A.ID 1N77 STR ENG THE PDXY(MIN. 12' EMBED), R21100 TOWOOD). (1)5/6`AT.µ.. IN HIGH STRENGTH EPO%Y(MIN.IT EMBED)(2)]WTO D H UGT2« 95]5 HGT3a i3690 WOOD 10130d, ASON712j3/4"A.TA 121E/4'AT.R:IN HIGH STRINGER fP6%V(MIN, 12 EMBED), 6) IM TO 00 H URN E., IOF3 10690 I. MIRKY (8) Fd, MASON. 2) SO, A'R (F0/4"A.T.R-IN HIGH SIAPPOINT EPO%Y(MIR 12 FROM), 6) IM TG!IOD W IA 15ROPARALLELTOWALL 3mOPLnPEry Dlcuwnia WALL LTA2 121D PARALLE ITO WALL 1210 PE RPENOICLIAR TO WALL ILI 10dx 11/2' (Ill Old R 1�1/2" MUGT35 A. OPT v4540 11f5/O AT R.TN HIGH 5'IRENOTX EPDXY (MIN .12"EMBEB),(41100 TOWEL] 106 FACLR12) 10d BACK OFTRUBS (1)SIR "4.T. R IN HIGH STRENGTH FPO%Y(MIN _1]"EMHED)I1)SITE 1/4'3" Y JET 95]S IE)RST 718S (2)5/8 HIL ATR, IN R IIGH STRENGTH EPDXY (MIN 12"EMBED).(8)1IF (2)S/8"A.T.µ. IN HIGH 51 RENGTH EPDXY (MIN. 12' EMBED),(3)5051/4''3" MTW 12 965 MITI 12 9DO IN, Ild X 11/2': 14)1W (14)10d X11/2" 1 HTWI6 1355 XTv6 1311, (" ILL X1I/2"p6pDd (26)IN xi112' Fr.. 11. XTS20 IS. IGQ 10d%110"(2D)1W (24)10d%11/2- HTW24 ill, XT524 il. LMO I011 x 1112' DD)]M (24]ICE .911R" LSTA 121? 930 LSTA 12«1 925 401 Ill PLO 1W L51A18- 1235 OTFA 181+ 1235 IItlY IOH (14)1W. MSTA-18«« 1310 MSTATIE. 1315 (NO d (14)1W MSTA-241« 'E. MSTA DR «« 164" CUP 1- (1811W y, M1IA-30«« 20. MSTX..- 2050 (22II 1N (22)1M ` �. M5TA-36«« 2065 MSTA-36M ENE. 120Did (")TOO (51I236 2765 SII5TI 36 Elm {36V IDtl %11R" (36)RUN X11/2" I. STEP. SLID MST14. 1020 {911II ]Btl%13/2', ED)Iid A11/2" SCAB 9s) H6 1055 pEP Bd x11IF, ,(HE) CR) (R) ed TO PLATES, (9jBE TU9vfn - 5114 1 875 5Vq -825. jib) FOR TO SHRDy(6) 1 IkTD FAIL (6)FOR x 11/2°TO STUDS M134 5251N`1911lW% All 110 (41 Ed 111/2• TO"AM, 14111111/110 1 (4)Ed Xl 112' T O B EA M.(418 d a 11/2'TO POST. HY.CP2 600 FIRE 590 (]Oy lO4X13/2' OTRUSS (]O)10d%1]/2'.TOPUTE (1E)10d%11/2" LIPA 3020 HOA.. OF. (9110dx11/2" TO TRUSS, (8) 100 Xi 1/2-TOPLATE j1X)30d 1111/2" MUGT16&PH. 4175 VGT&I. IND (ERR l00 TO TRVSPS, I TII) W53 WOOD SCREWS 10 PORT W/S/0"THREADED ROD. (16)SDS.1/4'x3"TDWOOD, I10YSDS 1/4"x21/2'W/THREA ED AND, (1) ITS/WASH HRYP PLY �. AA"G 111E PHIIIA 4111 'D,&FLY. 494D (28y 19c TOTRUSS, (10)W53 WOOD SCREWS TO POI 5/8"TH RFADEO ROD.. (16) SPIN 1/4 xi TO WOOD, (31-3/4'•STUDBOLTS W/ THREAD ROUX (2)U1S/WASHERI2PLY' $j PAU44 2E3E 6]]5 ABV40L. $300 ]]50 (1)a/B A.T.A.INHGNSTIIFN41'H lVO%Y,(MIN]"EMBEO)IN CONC.,p2)]6tl TOWCOO p)SIR "Ai.R IYHIGF STRENGTH EPDXY, (MI N) J"EMBED IN ONC:,p2)]6tl TOWOOU I+ 2455 16005 ABUe6Z 2190 18ZD5 (1)S/8 A. T.R. IN HIGHSTRENGTH EPO%Y(MIN] EMBED) IN CONC,(12)16tl TO WOOD (1)5/8"AT.R, IN H IS H STRENGTH EPDXY, )MIN. T'FROM) I CONC.,(121fitl TO WCOD % LTSN- 1205 LTT19 H«« 1310 (1)3/4'ATA I NJ H Oh STRLNGTH EPU%Y(MN T' EMBED) IN CONI(BILL TO WOOD (1)3/4"A.T. R I V H IGH STRENGTH EPDXY, (MI N I EM BED) I12YC,(0)1d 10 WOOD N IT 51.1 It 11.1FTLNFIT )50] (1)VIAT.R. IN HIGH STRENGTH EPDXY, (MI V]". EMBED) TN CDNIC,(10DOd 11IR TO WORD (1)1/2"A,II I N H OF 51 FIEND TH PROXY, (MI N i:'F.M BED) INOYC, IRO) ILL TO WOOD 9 1. HR45 4160 FUN .11 pT, )5/8"A.R IN IGHSTRENGTHEPO%YlMlnl] EMBED) IN CONC.,IIB) 16d RE 1/2' (1)S/8'•A.TST .RINHIGXRENGTHEPO%Y(MIN.]"EMBED,)IY N[(26)16dX21/2 IS HiTVS SOBS HERE 5090 (1)5/8" A.T.R.IN qIG H STXlN61 H EPDXY MIV ] EMBED) IN LONG, I261160 X 2112' (1)5/8'•A. T.I I N HIGF 51 RENGTH EPDXY IMIN.]'•END ED)IVINC.,(11) Ed X21/2 "1 I PHDII+- PHO]A 14395 fi525 HHD011-SDs 25«.. HDIB 11810 6645. (111 AT.R.INX GHSiRFNGTX EPDXY(MIN 10"EMBED) INCONC, (2411N334VCODSCREWS (115/0'A.B.INPUS H STRENGTH FFOXY, (MIN T EMBFO)INCONO pq W53WWOSCREWS (1)1"A.i.R.IVYIGF STRENGTH EPDXY, (MIN .3P'EMBED II (])]/8"A.B.I4Y-16N STRENGTH EPDXY, (MIN T'EMBED IN CONC.,(245DS NC., (3136'SND30 Y. X2H 1N000 SCREWS Li5TO WOOD I Lim ]0]0 Ill 1/8" A.B.INH GH Si R TRUTH EPV%((MIN/"EMBEOIMCONL(3)]/8" SIIIDBOLISTO WCOO NFM35%T1J 25HD ]1M .L.A. 3_S6/11.25 34] 5390 INP12"I'ROLT MIN fi"EMSEURECT!"S5FXAN4" FROMf WEOFCONCN 3/4' LAITWBAMYT/RFDHEAD M/ (]h)1) ISNSA BOLTSLEEl1EAN f.MDROREq W/M N$' LMOLINSTALLEDNFARE dAIRAST (313/4'•A.T.R.I VHIGXSTRfNGTHEPO%Y(MN6.]5"EMdLII EPO%Y,(MIV.X.]5" EMBEDMENT INC.VU.MCE,(1010tl iOEAM ENEIINC. M I1.1OP,(1)3/4"AT.RINHIGHSTRENGTH NU54121F 361i 2�10 (1X%1 HUSG32 (WOOD1 343Y 2635 (]CO'%) 1�' 16d TO H EAdE R(10116d TO WOOD (10, 16d TO H EAGER, (10) 36d TO WOOD y325(12596) 3220 (125%) Np 6 SHD6101F (CMU). '1950 3000 (CMUi PCMU) 18W 45W ya••va•,• 535Cuw5d1Dl1m ro �(OO D.USF(20) /lfi°i TAPFf R«, (lOJ 1M FO W006 (18)1/4x2-3/4_iITfN (9 PER FLAVGE)TO GN U,(10)IW iO D d = HU210.21F(CMU1 ]950 30B0 HOF? R.2 (CMU) 10CU 45CU 1/4,•"45"•. 55^^��58 SCefv6,f]o11WT0 OD. RSP(20)9flfi TAPPERH,(I0)1WTOWOOD p8)1/4",X2'3/4" THEN(9 PER FLANGE)TOCMU,(IB)3WT0 0" N021031f (CMJ 2795 505 HHO UP ICMU) IeCO 4500 }(}33/4 "'X3'' S35CREW$(10)1W i0 9Y@,0D USP(2U) /16 TAPPER ,(IOjIW TO WWD (]g)1/yx28/4"TITFN (9 PFREIANGE TOCMU, 11011W i0N W. LG'.1M)M1l 2125 60fi5 L6VR12 fi-2dD 3430 5595 Qtr13/0 X4'Wed ¢60IR AICM1OIS.LYWD(41W53WCODSCREWS (413/8x4TITEN HDANCHOR5I2 PER FWNGE)TOCMU,I4)14X2,]/2SLj.E.TOWOOD x � O 1A m 0 3.1 cm 0 i 2 (; 0 0 C3. coo O� N O @ (- � U O 00 ca Q cr N OLL (3j O -j Z Z U O ¢ cr Q m Q 0 0 U { IN CJ1A S/ n EE EJ3 IE \4 CJ1A o A � � 1A GT 11 D3GI 1A 16 3.1 3.1 D2 c) m nn co 4A-7- D1 U U T �7 CJi u u f 11II L �_=u w u u u u n l CJ1 7 II CJ3 = u u u n u = n n u u 11 It u n = CJ3 0 II II II II II II II II II II II II CJ5 -_= u n u u n I u u n n n u u u = CJ5 IL 11 EJ7A 11 11 _ GT 11 16 A14G 3.1 I I 6 I'W S3.1 -- ---- - - ----_ 1A I: )i PRE -FABRICATE ROOF x2 TRUSSES @ 24" O. . MAX. _o r 1A 3.1 IF IF g ; I I I Ili I I I 1 _.- � _- A1A I I I I I I - L - I 22"x54"I ATTIC ACCESS = A Reviewed fo, Code Compliance - Universal Exlylneering I I I Sciences _ AZ I I I I I y A1.1 JP A13 1A --- 1A I �7< (cI 3.1 3.1 I I I 1I A15 1A3.) - _ / \ / \ ----- \ / \REIN, / A16\ c\ CiGE - __ _ B1CF 7 8 7 g 3,1 3.1 3.1 3.1 FRAMING PLAN SCALE: 1/4" = V-0" _ J 2194 H WY A1A, SUITE 301 INDIAN HARBOUR BEACH, FLORIDA 32937 PH: 321-802 3591 www.abdesigngroup.com AA #: 0003325 E x i SURDIV 8e LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT# 04321.200 027R1 MODEL: 4EBB "1828-CALI" GARAGE SWING: RIGHT PAGE: yy �.1 I FRAMING PLAN I) 160 MPH EXP. C MAR 19- 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 03 17 21 DATE: / / SCALE: 1 /4"=1' - O" SHEET S 3 y ENGINEERED WOO TRSSE PLYWOOD SHEATHING, SEE @ 24" O/C, SUBMIT HOP II "ROOF/WALUFLOOR DRAWINGS FOR RE IEW SHEATHING AND APPROVAL FASTENER SCHEDULE" A-(1) SIMPSON HETA16 TRUSS ANCHOR WITH - PLYWOOD SHEATHING, SEE (9) 10d x 1 1" NAILS TO TRUSS z "ROOFJWALL/FLOOR T USSANSIMPSON OR WITH TRUSS ANCHOR WI H NOTE: APT SYP #2 2" x 4", B-(2) SIMPSON HETA16 TRUSS ANCHOR WITH SHEATHING 1 (9) 10d x 1 z NAILS TO 6", 8" x 4'-0" MAY BE ADDED (12) 16d x 1 2" NAILS TO TRUSS FASTENER SCHEDULE" GIRDER. PROVIDE " W/ 10d NAILS, 2 ROWS, 3' DBL STRAP, 1 EACH SIDE WRAPS UP AND MINIMUM E O/C TO FACILITATE ONE OVER TRUSS (NOT SHOWN) T. USE EMBEDMENT. USE IN ADDITIONAL PLY MAX. TO C-(1) SIMPSON LGT2 GIRDER TIEDOWN WITH NOTE: A PT SYP #22" x 4", CONJUNCTION WITH ACCOMMODATE GIRDER (16) 10d x 3 4" NAILS TO GIRDER AND 6", 8" x 4'-0" MAY BE ADDED 4,ACCOMMODATE HEAVY UPLIFT TIEDOWN REQUIREMENTS. (2) SIMPSON HETA16 TRUSS ANCHORS W/ 10d NAILS, 2 ROWS, 3" CONNECTOR WITH (12) 16d x 3 z" NAILS TO GIRDER O/C TO FACILITATE ONE ADDITIONAL PLY MAX. TO - A-(1) SIMPSON LGT3-SDS2.5 GIRDER TIEDOWN 1x2, 2x WOOD FASCIA r5; TRUSS WITH (4) e' x 5"TITEN HD TO CMU AND (12) SDS SEE ARCHITECTURAL - ANCHOR REQUIREMENTS. '-,° x 2 2" TO GIRDER 2x SECURED W/ (3) 16d — B-(1)SIMPSON FGTR GIRDER TIEDOWN WITH GALV. COMMON NAILS. ENGI 8S EERED WOOD -i x (2) 1z„ x 5" TITEN HD TO CMU AND (18) SDS , 1x2 SECURED W/ 10d - TRUES 9 24" O/C, 1 x2, 2x WOOD FAS 1A 3" TO GIRDER GALV. COMMON NAILS SUBMIT SHOP DRAWINGS SEE ARCHITECTUR L !, C-(2) SIMPSON FGTR GIRDER TIEDOWNS WITH 12" O/C FOR REVIEW 2x SECURED W/ (3) 16d ! AND AP PROVAL GALV. COMMON NAILS. (2) Z" x 5"TITEN HD TO CMU AND (18) SDS 4" x 3" 1x2 SECURED W/ 1 d MASONRYBOND SCREWS TO GIRDER (EACH TIEDOWN) GALV. COMMON NAILS BEAM ENSURE THAT CELLS ARE GROUTED MASONRY BOND BEAM 12" O/C SEE SCHEDULE SOLID, 8" EACH WAY OF BOLTS SEE SCHEDULE A ALLOWABLE UPLIFT = UA 810 LBS, ILi770 LBS (1 PLY) A ALLOWABLE UPLIFT = 3285 LBS (2 OR 3 PLY) B ALLOWABLE UPLIFT = U:2365 LBS,!L:1430 LBS (2 OR 3 PLY) ALLOWABLE UPLIFT = 4725 LBS (2 PLY MIN.) C ALLOWABLE UPLIFT = U:2705 LBS (2 PLY) C ALLOWABLE UPLIFT = 8885 LBS (2 PLY MIN.) TYPICAL TRUSS/ 1 a 1 b 1 C scALE:3/4„=1'-0" I TYPICAL ROOF GIRDER CONNECTORS) 2a 2b 2c GIRDER CONNECTOR(S) SCALE:3/4"=V-0' # 1100 UPLIFT SIMPSON - HTSM20 W/1010dTO TRUSS AND (4) 1/4" x 2 1/4" TITEN 2 ANCHORS TO CONT POURED LINTEL # 1900 UPLIFT (2) SIMPSON HTSM20 INSTALLED ON OPPOSITE FACES OF BLOCK WALL W/10 10d TO TRUSS AND (4) 1/4" x 21/4" TITEN 2 ANCHORS TO CONT POURED LINTEL PRE—ENG TRUSS 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH, CONTINUOUS BOND BEAM FLORIDA32937 I PH:321-802-3591 www: a bd es i g ngrou p. com TITEN 2 ANCHORS MIN. 2" COVER & 2" APART REPAIR OF MULTIPLE MISPLACED EMBEDDED TRUSS ANCHOR SCALE: 3/4' -1' 0 , d (2) 2X4 No.2 SYP DIAG. 2x4 BLOCKING BETWEEN 9 BRACE W/ (3) 12d @ EA: TRUSSES WHERE I TRUSS (DIAG. BRACE TO X-BRACING IS PRESENT AT COVER 5 TRUSSES) 4'-0" O.C. (AT SHEATHING 0'-0" TO 30'-0„ (1) „X" BRACE SEAMS) 30' 1" TO 60'-0 (3) "X" BRACE SECURE 2x PT. PLATE 6-0" MAX (W/1 X4) (1) "X" BRACE @ CENTER TO ELK W/1/2" DIA. OR 10'-0" MAX (W/2X4) (2) "X" BRACE DIVIDED EQUALLY ANCHOR BOLT W/ 2" v. v FROM CENTER TO END. WASHER SET IN HIGH D FASCIA. STRENGTH EPDXY6" 2x W00 C . MIN. EMBED. AT 32" OC Ix4 DIAGONAL SEE ARCHITECTURAL BTM. CHORD MAX. BRACING, SEE PRE ENG GABLE TRUSS -- SECURE GABLE TO8" PLAN FOR LOCATION O C. MAX PLATE W/ 12d's 8" o ZD U d MAY NOT BE STIFFRACK (AS PER - - l ct) , -J > REQUIRED TRUSS ENG) CONT 2x4 SECURED W/ X iv F- a H (2) 10d's @ EACH TRUSS TO BE INSTALLED @ BTM. CHORD OF 10'-0" O.C. MAX. i WOOD ROOF TRUSSES SEE SCHEDULE FOR - BOND 7pT� 1x4 BTM. CHORD BRACING 6'-0" O/C END WALL OR OTHER C REEKS IDE MAX., OR 2x4 BTM. CHORD BRACING END TYPE CONDITION, IF PHASE 10'-0" O/C MAXSECURED W/ (2) 10d DEPICTED SEE PLAN I- HAS E 2 COMMON NAILS AT EACH CHORD ! INTERSECTION TYP. 1 ! LOT # 2 fry BTM" CHORD BRACING BLOCK WALL W/ GABLE END r 6 7 1 SCALE:3/4„=,,_0,, I PROJECT# PRE ENG D TR SS 14kD NOTCH DEPTH / HOLE EDGE>5/8" HOLE DIAMETER L. STUD OUTER iPLATZEi SPAN O HOLE EDGE >5/8„ HOLE DIAMETER <3/5`D DBL. STUD STUD NOTCHING AND BORING LIMITS SCALE: 1 112"=V-0" - U 04321.200 027R1 mODErk: 4EBB „1828-CALL, ' ARAGYE SWINGY: �RIGHT I Reviewed for C<. -- -" Gg Compliance PAGE: Universal Engine, Sciences THE USE OF ALTERNATE MATERIALS MAY BE DETAILS USED SO LONG AS THEY CONFORM TO THE FOLLOWING 160 4 11 EXP C' 1. METAL STRAPS FOR ROOF AND FLOOR CONNECTIONS ARCHITECT A) AN ALTERNATE STRAP MAY BE USED SO LONG AS THE NEW STRAP HAS STATE OF FLORIDA EQUIVALENT OR GREATER UPLIFT AND LATERAL,(F1 AND F2) LOAD CAPACITIES AS THE ONE SPECIFIED, CONCURRENTLY. IT SHOULD BE NOTED FLOOR AND a ROOF TRUSSES ARE SUBJECT TO LATERAL LOADS DUE TO WIND AND REQUIRE THE CONNECTIONS INDICATED. A FLAT OR TWIST STRIP IS NOT EQUIVALENT TO A SIMPSON H10A OR LGT2. ROOF TRUSSES ARE SUBJECT TO UPLIFT, F1, AND F2 I' — FORCES ALL AT THE SAME TIME. FLOOR TRUSSES NOT EXPOSED TO WIND ARE — SUBJECT TO F1 AND F2 FORCES. MAR 19 2Q2"1, Idll`J4AFI f _ ANnFRSf1N AR NO 17305 f3PRINTATE: / /03 17 21 CALE: 1/4"=f-O" HEET S3e1. r A PRE-ENG GABLE TRUSS — 2x4 BLOCKING BETWEEN TRUSSES AT FIRST TWO BAYS 4'-0" O.C. (AT SHEATHING SEAMS) (BLOCKING NOT SHOWN FOR CLARITY) 2X4 DIAGONAL BTM. CHORD BRACING. SEE PLAN FOR LOCATION 01 SECURE 2x6 PT. PLATE TO BLK W/1/2" DIA. ANCHOR BOLT W/2" WASHER SET IN HIGH STRENGTH EPDXY 6" MIN. EMBED. AT 32" OC MAX. SECURE GABLE TO 2x8 P.T. PLATE W/ 12d's 8" O.C. MAX i 0 PRE-ENG'D WOOD TRUSS JYP) @ 24" O.C. MAX FOR STRAPPING VERIFY W'TRUSSPLAN (-,(.)NC - POURED LINTEL COURSE CONT. 2x4 SECURED W/ (2) 10d's @ EACH TRUSS TO BE INSTALLED @ 10'-0" O.C. MAX. GABLE END BRACING W1 PRE-ENG GABLE TRUSS @a CMU WALL SGALt: 3/4"=1'-U Reviewed fo, Cod., Compliance Universal Eggineenny Sciences 2194 HWY A1A. SUITJ301 INDIAN HARBOUR BFLORIDA3293PH: 321-802-35www.abdesigngrou AA #: 0003325 SUBDIV. 8e LOT: CREEKSIDE PHASE 2 LOT #27 PROJECT* 04321.200 027R1 MODEL: 4EBB "1828—CALI" GARAGE SWING: RIGHT PAGE: AILS LEDEET MPH EXP. C ARCHITECT: STATE OF FLORIDA VAR 19 2n?1 MICHAEL C. ANDERSON AR NO 17305 PRINT DATE: 03 17 21 SCALE: 1/4"=1'-0" SHEET S3e 1B 2x4 BLOCKING BETWEEN TRUSSES (2) 2X4 No.2 SYP DIAL. WHERE X-BRACING IS PRESENT AT BRACE W/ (3) 12d @ EA. 4'-0" O.C. (AT SHEATHING SEAMS) TRUSS (DIAG. BRACE TO COVER 5 TRUSSES) 0 0" TO 30 0'(1) "X" BRACE 30 1" TO 60'-0 (3) "X" BRACE PRE ENG GABLE TRUSS (1)'X' BRACE @ CENTER (2) "X" BRACE DIVIDED EQUALLY STIFFBACK AT ALL 2x SUB -BAND FROM CENTER TO END. UPRIGHTS OVER 4'-10" HIGH (AS PER TRUSSENG) PLYWOOD SHEATHING, SEE "ROOF/WALUFLOOR SHEATHING FASTENER SCHEDULE" SEE TYP. TRUSS CONNECTOR DETAIL FOR STRAPPING INFO. ix2, 2x WOOD FASCIA CONNECTION PER SEE ARCHITECTURAL TRUSS MFG. 2x SECURED W/ (3) 16d ENGINEERED WOOD GALV. COMMON NAILS. TRUSSES @ 24" O/C, 1x2 SECURED W/ 10d SUBMIT SHOP DRAWINGS GALV. COMMON NAILS FOR REVIEW CONT. 2x4 RAT RUN 12" O/C AND APPROVAL SECURED W/ (2) 12d's @ MASONRY BOND BEAM EACH TRUSS SEE SCHEDULE ' GABLE END PRE-ENG'D TRUSS 1 W1 HIP RETURN SCALE`S/4"=1'-0" VTCR i SIDE VIEW VTCR SPACING (1) AT EA AND 6'-0" O PRE-ENGINEERED r VALLEY TRUSS CONNECTION i 2 SCALE: N.T.S. Reviewed for Cod, Compliance UPtv"sal Engine. Sciences 2194 HWY A1A, SUITE 301 INDIAN HARBOUR BEACH. FLORIDA 32937 PH:321-802-35'31 www.abdesigngroup.com AA #: 0003325 00 9U3BDIV. 8e LOT:. CREEKSIDE PHASE '2 LOT #27 PROJECT# 0321.200 027R1L DE• 4EBB 1828- CALIR" GARAGE SWING: RIGHT PAGE: kl, DETAILS 160 MPH EXP. C ARCHn'ECT STATE OF FLORIDA t MAR 19 2021 MICHAEL C. ANDERSON AR NO 17305 PRINT 1'7 21 DATE- 03 /L SCALE: 1/4 =l'-O" SHEET Sao 1'� t t41 GABLE - END I c a 013 O � v 0 0 0 0 a 2E 0 0 0 V 0 V� 3 a ksvvvvvvv vvv vvv jF-- HIP ROOF------�F ROOF WIND DESIGNPRESSURES NET (GROSS) ASCE 7-16 ZONE 1 =52.70 PSF (62.70) ZONE 3 = 60.50 PSF (70.50) ZONE2e = 60.50 PSF (70.50)1 ZONE 3e = 69.80 PSF (79,80) ZONE 2n = 69.80 PSF (79.80) ZONE 3r = 83.80 PSF (93.80) ZONE 2r = 69.80 PSF (79.80) "A"= 4'-0" END ZONE DISTANCE BASIC WIND SPEED: 160 MPH EXPOSURE CATEGORY: "C" RISK CATAGORY: II APPLICABLE INTERNAL PRESSURE COEFFICIENT: +/- 0.18 ROOF DIAPHRAGM FOR ASPHALT HIN LE ROOF, USE MIN 7/16"STRUCTURAL SHEATHING EXP 1(24/16) or 15/32"STRUCTURAL SHEATHING EXP 11 (32/16), FOR CEMENTITIOUS TILE AND METAL ROOFING; USE 15/32'I1 STRUCTURAL SHEATHING EXP 1 (32/16) .(SEE TABLE FOR FIELD AD EDGE SPACING) SEE DETAIL. ROOF SHEATHING TO GABLE END FRAME USE 8d RING SHANK GUN NAILS @ 4" O.C. EDGEWISE 2x4 BLOCKING ALL PANEL JOINTS W/ IN14' OF GABLE END. WAL FLOOR ROOF/ L/ 00 SHEATHING FASTENER SCHEDULE NAIL REQUIREMENTS SIZE HEAD LENGTH DIA. TENSILE STIR. SHANK ASTM 8d RING SHANK, 2 5/8" 0.113 170,000 RING (16-20 RINGS. RSRS-01 RSRS SCREW SHANK PER INCH) 8d RING SHANK, 23/8" 0.113 F1667 PNEUMATIC RSRS-01 SCREW -NAILS EXTERIOR SHEATHING USE 1/2" CDX OR 7/16" O.S.B. PLY WITH 8d RING SHANK GUN NAILS AT 4" O.C. AT PANEL SIDES AND 8d RING SHANK GUN NAILS 4" O.C. TOP & RAFTER OR TRUSS BOTTOM PANEL AND 8d RING SHANK GUN NAILS AT 6" O.C. AT ROOF SHEATHING INTERMEDIATE SUPPORTS OR 7/16" ZIP SHEATHING SYSTEM (INSTALLED PER MANUR SPECS.) SEE DETAIL. ROOF SHEATHING ATTACHEMENT SPACING ZONES 1: 8d NAILS @ 4 O.C. ON EDGE AND 6" O.C. IN FIELD ZONE 2e 2n, 2r: 8d NAILS 4" O.C. ON EDGE AND 4" O,C. INFIELD -- -� ZONE 3,3e, 3r. 8d NAILS @ 4" O.C. ON EDGE AND 4" O.C. IN FIELD � BUILDING LENGTH � NOTE: ROOF SHEATHING THICKNESS WAS CALCULATED ROOF SHEATHING LAYOUT AND ADHERES TO ASCE 7-16 AND ENDWALL BRACING FOR GABLE END FRAMING NOTE' GABLES -DROP GABLE END & 11) ADD'L DROPPED Kr (3j co Z LU 2! Z ❑ W Z =O to 0 Z E 00 8d RING SHANK GUN NAILS @ 4" O.C. - TOP & BOTTOM EDGES @! J Q Z Z . Y w a z W z L5 0, 4. -1 _ TYP. EXT. SHEATHING ATTACHMENT A. Z0 w V W w w w C w 1e@ 00 O O N (D CO TRUSS 2x4 #2 SYP OUTLOOKER RAFTER W/ BLOCKING @ 16"O.C. IF NO DROPPED GABLE END, ATTACH 2x4 #2 SYP BLOCKING ,@ 16" O.C. FIRST 4 BAYS W/ (2)12d NAILS EA. END. ATTACH ROOF SHEATHING TO RAFTERS 2l BLOCKING PER NAILING SCHEDULE C8d RING SHANK GUN NAILS SEE "ROOF SHEATHING ATTACHMENT' TABLE FOR FIELD SPACING `YP. EXT. SHEATHING ATTACHMENT FOR STRUCTURAL ROOF (—#8'2"DECK SCREWS @ 6"-8" O.C. MAX @ EDGES & 12" O.C. MAX IN FIELD. UNTHREADED SHANK TO EXTEND BEYOND THICKNESS OF SUB -FLOOR SHEATHING -I T'P. 3/4" T&G SUB -FLOOR DECKING GLUED TO ALL EXPOSED MEMBERS i GENERAL NOTES: ALL AGGREGATE USED IN CONCRETE SHALL CONFORM TO ASTM C33/C33M. MAXIMUM AGGREGATE SIZE SHALL BE 3/4". $TRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB SPECIFICATIONS AND WOOD: A RCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND SITE DRAWINGS. CONSULT PROVIDE 6% AIR ENTRAINED CONCRETE EXPOSED TO EARTH OR WEATHER Ni)N-BEARING -. , - AR ARCHITECTURAL DRAWINGS FOR SLEEVES, DEPRESSIONS, AND OTHER DETAILS NOT. SHOWN c H IT E c T s ON STRUCTURAL DRAWINGS. APPLICABLE BUILDING CODE:STANDARDS: FBC-R 2020, 7th EDITION ALL EXPOSED EDGES OF CONCRETE ARE TO BE CHAMFERED 3/4". Al I_ WOOD FO ACI 318-14, BUILDING CODE REQUIREMENTS ': CRIPPI FRS, S FOR STRUCTURAL CONCRETE, TM5 402/602-16 AISI SPECIFICATION FOR THE DESIGN OF PROVIDE 6-MIL CONTINUOUS POLYETHYLENE VAPOR BARRIER MEMBRANE UNDER ALL SLABS -ON -GROUND WHERE INDICATED ON - FJ AS I ICI FY COLD-FORMEDSTEELSTRUCTURAL MEMBERS 2018, ASCE 7-16 AND AISC'SPECIFICATIONS . DRAWINGSSEAMS LAPPED 6 INCHES AND SEALED WITH ADHESIVE TAPE. PRESSURE TR FORM -WORK: SHALL BE RAT. sign I-Ou'P ALL DETAILS AND SECTIONS SHOW ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND CORROBORAI � SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, FORM -WORK, SHORING, AND BRACING. FOR ALL CONCRETE BEAMS, SLABS, COLUMNS, WALLS, REASON SHAL - -- _-- --- EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. AND FOOTINGS SHALL BE DESIGNED AND CONSTRUCTED IN ACCORDANCE WITH ACI 347 LATEST W/ DOT SHALL April 21, 2021 - - EDITION, "RECOMMENDED PRACTICE FOR CONCRETE FORM -WORK. CONTAINS MO - DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD. DO NOT SCALE THE 4L AWINGS. FOLLOW WRITTEN DIMENSIONS ONLY. ANY DISCREPANCIES SHALL BE BROUGHT EXCLUSIONS FROM THESE PLANS: MINIMUM NAIL Planning & Development Services , TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THEAFFECTED PART WATERPROOFING, FLASHING, SOUND ISOLATION, FIRE SEPARATION,. OR OTHER NON STRUCTURAL ITEMS - Building .& Code Regulation Division OF THE. WORK. ARE NOT PART OF THE STRUCTURAL PLANS AS THEY ARE NOT CONSIDERED TO BE STRUCTURAL.DEPENDING PROVIDE SOLI. _ 2300 Virginia Ave: ON THE TYPE OF CONSTRUCTION THESE ITEMS SOME OR ALL MAY BE REQUIRED BUT ARE BY OTHERS. SYP 92. - Fort Pierce, Fl: 34982 THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE ERECTION PROCEDURES AND UNTREATED V. -. -..(772)462-2172 - SEQUENCES TO INSURE SAFETY OF THE BUILDING AND ITS COMPONENTS WELDED. WIRE MESH: AT BEARING L. DURING ERECTION. THIS WORK INCLUDES THE ADDITION OF NECESSARY SHORING SHEETING, TEMPORARY BRACING, GUYS OR TIE -DOWNS. ` WELDED WIRE MESH, SHALL BE ASTM A1064/A7064M, GRADE 65 AND BE PLACED IN ACCORDANCE WITH THE WOOD TR RE: Permit # ACI TYPICAL DETAILS. MINIMUM LAP SHALL BE ONE SPACE PLUS TWO INCHES. WIRE MESH FOR SLABS SHALL D.R. Horton Homes THE CONTRACTOR SHALL SUPPLEMENT THE MINIMUM REQUIRED FOUNDATION AND SITE PREPARATION BE SUPPORTED WITH 2" CHAIRS SPACED 3'-0"OC, EACH WAY. TO BE DESIGN STRESS GRAE Creekside Lot 27 REQUIREMENTS AND SLAB -ON -GRADE THICKNESS TO HANDLE CONSTRUCTION LOADS. SEALED BY A I Response Letter DO NOT SCALE DRAWINGS. THE CONTRACTOR AND SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS PRIOR REINFORCING STEEL: CONNECTOR F O.WORK.PERFORMED AND SHALL NOTIFY THE ARCHITECT IF ANY DISCREPANCIES ARE FOUND. : REBAR SHALL BE ASTM A615A615M GRADE 40 IN CONCRETE DEFORMED BARS, REBAR SHALL BE ASTM A615 MEETING THE GRADE 60 IN MASONRY DEFORMED BARS, FREE FROM OIL, SCALE, AND RUST AND PLACED IN ACCORDANCE For the above listed project, the plans indicate 7/16 .roof Sheathing on Sheet SNl. - DESIGN LOADS: W/ THE TYPICAL BENDING DIAGRAM AND PLACING DETAILS OF THE ACI STANDARDS AND SPECIFICATIONS. DESIGN, FABIR This is an error on the plans. The Correct callout Shall be 19/32" Sheathing thickness and CONTRACTOR SHALL SUBMIT REBAR SHOP DRAWINGS FOR REVIEW PRIOR TO FABRICATION. HORIZONTAL STANDARDS F the correct reference for Wind pressures i5 ASCE 7-16 reference. AND VERTICAL BARS SHALL LAP 6 x BAR NO. UNSCHEDULED FIELD LAPS ARE SUBJECT TO ENGINEER'S COMMENTARY COMMENTARY ROOF LIVE LOAD' FLOOR: LIVE LOAD 40 psf REVIEW. 20psf TOP CHORD -non-concurrent - TYP. MIN LAPS SHALL BE AS FOLLOWS: #4 BAR - 25" #6 BAR - 36" WOOD USSI 10 psf BTM CHORD -non-concurrent #5 BAR - 30" #7 BAR - 42" PROVIDE 36" x 36" CORNER BARS, BOND BEAM ONLY, LAPPED AND TIED TO EACH BEAM REBAR, SEE DETAILS TRUSS MANUF LOCATIONS W - DEAD LOAD DEAD LOAD FOR ADDITIONAL INFORMATION. INTERSECTION - a -- Cod - 15 pal TOP CHORD 20 psf TOP': CHORD I (7 psf w/ ASPHALT SHINGLES) psf w/ No GYPCRETE) I ALL VERTICAL REINFORCING IN BA IN MU CELL SHALL O C G BARS C S S BE ANCHORED IN THE FOOTING, HURRICANES g15,1%, e1 �� C 0 tn4 5 p 10 psf BTM CHORD 5 psf BTM CHORD THICKENED SLAB, BEAM OR LINTEL SUPPORTING THE WALL AT THE TOP AND BOTTOM WITH etEn9lneen"9 �S�Y� Sclen�g DEAD LOAD TO RESIST WIND UPLIFT: 10psf MINIMUM 10 INCH HOOKS OR BENDS AND SHALL BE CONTINUOUS THROUGHOUT THE HEIGHT OF THE CONTRACTOR BALCONY LIVE LOAD. 60 psf WALL TRUSSES/GIRT STAIRS LIVE LOAD 40 psf WIND: DEAD LOAD SPEED MPH S- SECONDC,RISK RUN REINFORCING BARS CONTINUOUSLY LAPPED AT SPLICES AND AROUND CORNERS. DOWEL ROOF & FLOOI CA {ASCE 7-16 (FBC R2020) EXPOSURE C; RISK CATEGORY II) 020) INTO INTERSECTING WALLS AND HOOK AT ENDS. STAGGER SPLICES WHEREVER POSSIBLE. DETERMINATK LIVE LOADS: UNINHABITABLE ATTIC WITHOUT STORAGE: 1 Opsf, UNINHABITABLE ATTIC WITH LIMITED LAYOUT, SPAN STORAGE:20psf, HABITABLE ATTICS AND ATTICS SERVED WITH FIXED STAIRS: BALCONIES (EXTERIOR) DO NOT CUT OR DISPLACE REINFORCING STEEL TO ACCOMMODATE THE INSTALLATION OF EMBEDDED ITEMS AFFECT THE S .30psf, AND DECKS: 40psf, GUARDS AND HANDRAILS: 200psf, GUARD IN -FILL COMPONENTS: 50p5f,.PASSENGER WITHOUT THE APPROVAL OF THE ENGINEER. STRUCTURAL I - VEHICLE GARAGES: 50psf, ROOMS. OTHER THAN SLEEPING ROOM: 40psf, SLEEPING ROOMS: 30psf, STAIRS: PROVIDE ENGi 40psf MASONRY: PLAN SHOWINi '.. MASONRY CONSTRUCTION AND MATERIALS SHALL CONFORM WITH ALL REQUIREMENTS OF THE LICENSED PRC SHOP DRAWING REVIEW: "SPECIFICATION MASONRY STRUCTURES" (TMS 402, BUILDING CODE REQUIREMENTS FOR MASONRY Should you have any questions, please feel free to contact rile. HOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGNING INTENT STRUCTURES AND SPECIFICATIONS FOR MASONRY STRUCTURES AND COMMENTARIES AS PUBLISHED BY )' THE HURRICAP CONSTRUCTIC -- - - F THE CONTRACT DOCUMENTS ONLY. IT SHALL BE THE RESPONSIBILITY,OF THE CONTRACTOR TO VERIFY THE MASONRY STANDARDS JOINT COMMITTEE. PROVIDED BY 'Sincerely,-, COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, ELEVATIONS, DIMENSIONS, ETC. THE TRUSS TC ALL BLOCK WALLS SHALL BE TWO CELL HOLLOW CONCRETE MASONRY REGULAR SIZE BLOCK ✓: ALL SHOP DRAWINGS SHALL BE REVIEWED BY THE CONTRACTORS PRIOR TO SUBMITTAL TO THE ARCHITECT. MANUFACTURED IN CONFORMANCE WITH ASTM C-90;. GRADE f'm = 2000 PSI.. BLOCK SHALL BE PLACED USING OF THE DELEC AND CLADDIN( DRAWINGS SUBD MITTS WITHOUT REVIEW WILL BE RETURNED UNCHECKED SHOP DRAWINGS IN THE FORM RUNNING BOND UNLESS OTHERWISE NOTED. LAY-UP MASONRY WALLS TO BOTTOM OF TIE BEAMS BEFORE ALL S TRLIS TO i F REPRODUCIBLE SEPIAS OF STRUCTURAL DRAWINGS (CON TRACT DOCUMENTS) ARE PROHIBITED REPRODUCIBLE PLACING F I - C G OR N WALL COLUMNS. GROUT USED T F US O ILL MASONRY CELLS SHALL COMPLY WITH % '`, •,,, OF EXPRESS WRITTEN PERMISSION FROM THE ENGINEER. IN ALL INSTANCES, THE CONTRACT. ASTM C-476, AND SHALL PROVIDE A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI AT 28 DAYS, UNLESS pQ C" DOCUMENTS WILL GOVERN OVER THE SHOP DRAWINGS CHECKED, UNLESS OTHERWISE SPECIFIED IN SPECIFICALLY NOTED OTHERWISE ON FOUNDATION PLAN. THE GROUT.MIX SHALL HAVE A MAXIMUM 3/8" /BITING BY THE ARCHITECT. COURSE AGGREGATE, AND SHALL BE PLACED W/ A SLUMP OF 8" TO 10". USE ONLY MECHANICAL VIBRATION TO CONSOLIDATE GROUT. �- _ l�h hael C. AnderSol ,FOUNDATION/ SITE PREPARATION: TYPE"M" OR "S" MORTAR SHALL BE USED EXCLUSIVELY ON THIS PROJECT. MORTAR SHALL BE Fl r o shitee � 305 FOOTINGS WERE DESIGNED FOR AN ALLOWABLE SOIL BEARING PRESSURE OF 2,000 psf, FOOTING PROPORTIONED AND MIXED AS OUTLINED UNDER ASTM C-270. HORIZONTAL AND VERTICAL MORTAR JOINTS _ = EXCAVATIONS AND SLAB SUB -GRADE SHALL BE COMPACTED TO A DRY DENSITY OF AT LEAST 95%OF THE SHALLBE3/S" THICK UNLESS OTHERWISE NOTED. REMOVE MORTAR PROTRUSIONS THAT EXTEND INTO MODIFIED PROCTOR MAXIMUM DRY DENSITY, DETERMINED IN ACCORDANCE WITH ASTM D-1557. TREAT ALL CELLS TO BE FILLED. SOIL FOR TERMITE PROTECTION. _ THE OWNER SHALL RETAIN THE SERVICES OF AN INDEPENDENT GEO TECHNICAL ENGINEER TO VERIFY FILL CMU CELLS SOLID WITH GROUT AT ALL CELLS TO RECEIVE EXPANSION ANCHORS AND/OR VERTICAL 2194 HwyAIA, Suite 301 Indian Harbour Beach, FL 32937 • Phone: (321) 802-3591 SUCCESSFUL: COMPLETION OF SITE PREPARATION EFFORTS. LOCATIONS FAILING TO MEET THE, REINFORCING. - www.abdesigngroup.com GEO-TECHNICAL ENGINEER'S REQUIREMENTS SHALL BE RE -COMPACTED AND RETESTED AT THE LAP VERTICAL REBAR 6 X BAR NO. (48 BAR DIAMETERS)., U.N.O._ CONTRACTORS EXPENSE, AND AS DIRECTED BY THE ARCHITECT. WRITTEN CERTIFICATION THAT THE MINIMUM DESIGN BEARING CAPACITY, AND THAT THE COMPACTION REQUIREMENTS HAVE BEEN MET SHALL STRUCTURAL STEEL: BE MADE BY THE GEO-TECH. ENGINEER. THE MATERIAL, FABRICATION, AND ERECTION OF STRUCTURAL STEEL SHALL COMPLY WITH THE CONCRETE: - SPECIFICATIONS FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR Bl/1LDINGS, 9TH EDITION, BY THE AMERICAN INSTITUTE. OF STEEL CONSTRUCTION. STRUCTURAL STEEL SHALL BE ASTM I' CONCRETE SHALL ACHIEVE MINIMUM 28 DAY COMPRESSIVE STRENGTHS AS FOLLOWS: A36/A36M, Fy = 36 ksi FOR ANGLES, PLATES, AND W-SHAPES. STRUCTURAL TUBING SHALL BE ASTM I CTRE EKSS IDE A500/A500M, GRADE B, Fy = 46 ksi. STRUCTURAL PIPE SHALL BE ASTM A53/A53M, GRADE B, TYPE E OR S, Fy = 2,500 PSI REGULAR WEIGHT FOR FOOTINGS, AND SLAB -ON -GRADE 35 ksi. TUBE AND PIPE COLUMNS SHALL BE CONCRETE -FILLED IN THE SHOP. PHASE 3,000 PSI REGULAR WEIGHT FOR BEAMS, COLUMNS, AND 5" STRUCTURAL TERRACE SLAB, WITH HISTORICAL STRENGTH DATA FOR EACH SEPARATE MIX PRIOR TO ANCHOR BOLTS AT THE COLUMN BASES SHALL BE ASTM A307 BOLTS WITH DOUBLE -NUT LEVELING. ALL ry - LOT # (- CONTRACTOR SHALL SUBMIT PROPOSED MIX DESIGNS, OTHER BOLTS SHALL BE ASTM F3125/F3125M BOLTS WITH WASHERS UNDER THE TURNED ELEMENT. BOLTS ( CONCRETE PLACEMENT. CONCRETE SLUMP SHALL NOT EXCEED 5" +/- PRIOR TO THE ADDITION OF PLASTICIZER. SHALL BE TIGHTENED IN ACCORDANCE WITH THE TURN -OFF -THE -NUT METHOD. Revj",ed for Code w II mpliance 1ZOJECT# CONCRETE SHALL COMPLY WITH ALL THE REQUIREMENTS OF ACI 318 AND ASTM C941C94M, OR MEASURING, MIXING, TRANSPORTING, ALL ANCHOR .BOLTS SHALL BEGALVANIZED STEEL. ARETOBE.STEEL. � 1 �J-BOLTS �i4321.200/027R1 ETC. CONCRETE TICKETS SHALL BE TIME -STAMPED WHEN CONCRETE IS BATCHED. THE MAXIMUM TIME ALLOWED FROM WHEN Scenceseenng WATER IS ADDED TO THE MIX UNTIL IT IS DEPOSITED IN ITS FINAL POSITION SHALL NOT EXCEED 90 MINUTES. IF FORANY REASON y®DEL: THERE IS A DELAY IN SUCH 'THAT .A BATCH IS HELD FOR LONGER THAN 90 MINUTES, THE CONCRETE SHALL NOT BE PLACED. IT SHALL BE THE RESPONSIBILITY OF THE TESTING LABORATORY TO NOTIFY THE OWNER'S REPRESENTATIVE AND THE CONTRACTOR OF ANY 4 E B B NON COMPLIANCE WITH THE ABOVE. >> ee 1828-CALI REQUIRED CONCRETE COVERAGE OVER REBAR SHALL BE AS FOLLOWS'. A. 3" FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH (FOUNDATIONS): GA ZAGE SWING: !. FOR CONCRETE EXPOSED TO EARTH AND/OR WEATHER, RIG.HT 1-1/2" FOR#5 AND SMALLER B �a 2"FOR#6 AND LARGER C. FOR CONCRETE NOT EXPOSED TO WEATHER _ :SAGE: 3/4" FOR SLABS, WALLS AND JOISTS `3 1-1/2" FOR BEAM AND COLUMN PRIMARY. REINFORCEMENT, TIES, STIRRUPS Id DETAILS FASTENER SCHEDULE WINDOW AND DOOR BUCK FASTENERS FASTENER E SI2 NOTE W✓WASHER STAGGERED EDGE DIST. NOTES 1. STAPLES SHALL NOT BE USED FOR ANY STRUCTURAL APPLICATIONS 2. FASTENING OF GARAGE DOORS, WINDOWS AND EXTERIOR SWING DOORS TO FRAMING BUCKS SHALL BE AS PER MANUFACTURER'S SPECS AND / OR NOA 3. ALL FASCIA MATERIAL SHALL BE HAND FRAMED 4.. PAF SHALL BE HILTI X-ZF.HEAVY DUTY PINS OR EQUAL SAME DIAMETER AS SPECIFIED HEREIN 5. FASTENER SPACING FOR THE BUCKS SHALL BE THE STRICTER REQUIREMENT OF THE NOA OR THE SPACING DETAILED ABOVE 6. WINDOW AND DOOR BUCKS SHALL BE AS WIDE OR WIDER AS THE DOOR OR WINDOW FRAME EXCEPT FOR AN EXTERIOR SWING DOOR WITH A WOOD DOOR FRAME. 1, MEMBERS ARE NAILED AND 2x MEMBERS ARE. SECURED Wr TAPCONS OR RAF TO THE SUBSTRATE. SI��PH SAP. C � FARCHI TEC1., STATE OF FF�m;' �e. 7 +d MAR 19 2021,IA MICHAEL C. ANDERSON f.a: AR NO 17305 PE2INT 03/ 17/ 21 DATE: SCALE: 1/4"=f—O" SHEET ) S N I Ij