Loading...
HomeMy WebLinkAboutIn-Place Density Report_Test-0001-0013_8355939�`uArdaman In -Place Density Report MO% & Associates, Inc. Report Date: 07/28/2021 Test Method: ASTM D6938 Port St. Lucie Branch Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 Client: D&D Welding 5300 S. STEELE BLVD. FORT PIERCE, FL 34946 Project: 113-20-64-5510A 5300 S Steele Blvd 5300 S Steele Blvd Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. N Remark 1 07/15/21 21-138 (Modified) A 11.0 108.0 6.8 106.5 113.7 12 99 95 Pass 2 07/15/21 21-138 (Modified) A 11.0 108.0 6.3 104.2 110.8 12 96 95 Pass 3 07/15/21 21-138 (Modified) A 11.0 108.0 4.2 102.9 107.2 12 95 95 Pass 4 07/15/21 21-138 (Modified) A 11.0 108.0 4.0 105.3 109.5 12 98 95 Pass 5 07/21/21 21-138 (Modified) A 11.0 108.0 15.9 102.1 118.3 12 95 95 Pass 6 07/21/21 21-138 (Modified) A 11.0 108.0 11.8 104.0 116.3 12 96 95 Pass 7 07/21/21 21-138 (Modified) A 11.0 108.0 11.5 105.6 117.7 12 98 95 Pass 8 07/21/21 21-138 (Modified) A 11.0 108.0 10.0 105.2 115.7 12 97 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1 Building Pad Fill: Building Pad Fill. E Building Area -1.0 Top of Existing CPN / MC-3 / M330907151 / Tech, Port St. Lucie 2 Building Pad Fill: Building Pad Fill. Center Building Area -1.0 Top of Existing CPN / MC-3 / M330907151 / Tech, Port St. Lucie 3 Building Pad Fill: Building Pad Fill. W Building Area -1.0 Top of Existing CPN / MC-3 / M330907151 / Tech, Port St. Lucie 4 Building Pad Fill: Building Pad Fill. N Area -1.0 lTop of Existing CPN / MC-3 / M330907151 / Tech, Port St. Lucie 5 Building Pad Fill: Building Pad Fill. E Area 1.0 Existing Ground CPN / MC-3 / M330907151 / Tech, Port St. Lucie 6 Building Pad Fill: Building Pad Fill. Center Area 1.0 Existing Ground CPN / MC-3 / M330907151 / Tech, Port St. Lucie 7 Building Pad Fill: Building Pad Fill. W Area 1.0 Existing Ground CPN / MC-3 / M330907151 / Tech, Port St. Lucie 8 Building Pad Fill: Building Pad Fill. N Area 1.0 Existing Ground CPN / MC-3 / M330907151 / Tech, Port St. Lucie Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 1 of 3 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. �`uArdaman In -Place Density Report MO% & Associates, Inc. Report Date: 07/28/2021 Test Method: ASTM D6938 Port St. Lucie Branch Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 Client: D&D Welding 5300 S. STEELE BLVD. FORT PIERCE, FL 34946 Project: 113-20-64-5510A 5300 S Steele Blvd 5300 S Steele Blvd Fort Pierce, FL Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. N Remark 9 07/26/21 21-138 (Modified) A 11.0 108.0 4.0 108.8 113.2 12 101 95 Pass 10 07/26/21 21-138 (Modified) A 11.0 108.0 5.3 107.6 113.3 12 100 95 Pass 11 07/26/21 21-138 (Modified) A 11.0 108.0 3.9 108.1 112.3 12 100 95 Pass 12 07/26/21 21-138 (Modified) A 11.0 108.0 4.8 107.7 112.9 12 100 95 Pass 13 07/26/21 21-138 (Modified) A 11.0 108.0 4.2 108.3 112.8 12 100 95 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 9 Building Pad Fill: Final Lift of Building Pad. NW Corner of Pad -1.0 Top of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 10 Building Pad Fill: Final Lift of Building Pad. NE Corner of Pad -1.0 Top of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 11 Building Pad Fill: Final Lift of Building Pad. Center of Pad -1.0 Top of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 12 Building Pad Fill: Final Lift of Building Pad. SW Corner of Pad 1 -1.0 1 Top of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie 13 Building Pad Fill: Final Lift of Building Pad. SE Corner of Pad -1.0 Top of pad Troxler / T-3430 / 21330 / Tech, Port St. Lucie Remarks Comments Pass: Density Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 2 of 3 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL. �'uArdaman In -Place Density Report MO% & Associates, Inc. Report Date: 07/28/2021 Test Method: ASTM D6938 Port St. Lucie Branch Florida Registration No. 5950 460 NW Concourse Place, Unit 1 Port St. Lucie, FL 34986 Phone:772-878-0072 Client: D&D Welding 5300 S. STEELE BLVD. FORT PIERCE, FL 34946 Project: 113-20-64-5510A 5300 S Steele Blvd 5300 S Steele Blvd Fort Pierce, FL This item has been digitally signed and sealed by Branch Manager Dan J. Zrallack, P.E. on Jul 29, 2021 using a Digital Signature. Printed copies of this document are not considered signed and sealed and the SHA authentication code must be verified on any electronic copies. AS A MUTUAL PROTECTION TO OUR CLIENT, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF Page 3 of 3 THE CLIENT, AND AUTHORIZATION FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OUR REPORTS IS RESERVED PENDIN( OUR WRITTEN APPROVAL.