HomeMy WebLinkAbout216203-1d Compaction signedHeadquarters
11345 U.S. Highway 1
Sebastian, FL. 32958
Orlando
723 Progress Way
Sanford, FL. 32771
Mailing
PO Box 78-1377
Sebastian, FL. 32978
Phone: 772-589-0712
C.A.# 5693
KSMengineering.net
KSM JOB #:216203-1d/BS/jam
NUC #528
Nuc Model:MC-1DR-P
Nuc Serial #:MD049528
93 Calle de Lagos
Spanish Lakes Country Club
Fort Pierce, Florida
Compacted Foundation Fill for House Pad
DEPTH PEN
READ
DRY
DENSITY
MAX. DRY
PROCTOR VALUE (P.C.F)
PERCENT
COMPACTION
1 N.E.0" - 12"45 108.1 109.2 99.0%
2 S.E."45 107.0 "98.0%
3 Center "45 107.3 "98.3%
4 S.W."45 106.8 "97.8%
5 N.W."45 107.5 "98.4%
Proctor Optimum Moisture:
Proctor Max. Dry Density: P.C.F.
@ Test Locations the Density &
Penetrometer readings indicate the
Degree of Compaction Meets
8/10/2021
Email to: dotty@wynnebc.com
PE # 68366
Test report shall not be reproduced, except in full, without the written approval of KSM Engineering & Testing
Soil Description:
JOB LOCATION:
PERMIT #:
CONTRACTOR:Wynne Development
21060700
Julie E. Keller, P.E. President
Respectfully Submitted:
ITEM TESTED:
109.2
TEST LOCATION
OF SAMPLE
Proudly Serving Florida since 1990
Disclaimer:Contractor is responsible to maintain the tested area
in the condition that KSM completed the indicated passed
compaction test.KSM is not responsible if the tested area has
been altered from the approved inspected condition.
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 6938
August 9, 2021DATE TESTED:
11.4%
12.0%
Brown Sand with Traces
Certified Women Owned Business - WBE
Minimum Requirement
of Shell Fragments
for Staked Foundation
In Place Moisture:
Geotechnical Engineering - Construction Materials Testing - Special Inspections - Civil and Structural Consulting
104.0
105.0
106.0
107.0
108.0
109.0
110.0
111.0
7 8 9 10 11 12 13 14 15
W
E
I
G
H
T
P
.
C
.
F
.
D
R
Y
Moisture -% of Dry Weight