HomeMy WebLinkAboutProduct Review Affidaviti
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
FL # or Miami -Dade
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
FL # or Miami -Dade
FLORIDA PRODUCT
REVISION EXPIRATION
Product
Model #
Manufacturer
Glass Description
Method of Attachment
Building Design
Product Design
APPROVAL REVISION
DATE
Pressure
Pressure
For anchoring through frame into wood framing or 2x buck use #10 wood screws with
sufficient length to achive a 1 1/4" minimum embed. Into substrate. Locate anchors as
FL17499.2
R8
10/08/2023
SH Window
185 SH
MI Window and
Non Impact
shown in elevations and installation details.For anchoring through frame into masonry
(+38)/(48)
(+50)/(-50)
Doors
/concrete use 3/16" tapcons with sufficient length to achive a 1 1/4" minimum
embed. Into substrate. Locate anchors as shown in elevations and installation details.
For anchoring through frame into wood framing or 2x buck use #10 wood screws with
sufficient length to achive a 1 3/8" minimum embed. Locate anchors as shown in
installation details.For anchoring through frame into masonry / concrete use 1/4"
MI Window and
ELCO ultracon tapcons with sufficient length to achive a 1 1/4" minimum embed. w/
FL15353.2
RS
12/31/2024
Vertical Mullion
5764
Doors
Non Impact
1' min. edge distance. Locate anchors as shown in installation d tails.
(+38) / (-48)
(+48.1 / (-48.1)
For anchoring through frame into wood framing or 2x buck use #10
wood screws with
sufficient length to achive a 1 1/4" minimum embed. Into substrate.
Locate anchors as
shown in elevations and installation details.For anchoring through
frame into masonry
MI Window and
/ concrete use 3/16" tapcons with sufficient length to achive a 1
1/4" minimum
FL15349.1
R14
4/3/2023
Fixed Window
185 PW
Doors
Non Impact
embed. Into substrate w/ min 2 1/2" edge distance. Locate anchors
as shown in
(+38) / (-48)
(+60) / (-60)
installation details.
For anchoring through frame into wood framing or 2x buck use #10
wood screws with
sufficient length to achive a 13/8" minimum embed. Into substrate.
Locate anchors as
shown in elevations and installation details.For anchoring through
frame into masonry
MI Window and
/ concrete use 3/16" tapcons with sufficient length to achive a 1
1/4" minimum
FL15332.2
R6
12/31/2024
Sliding Glass Door
Series 420 Aluminum SGD
Doors
Non Impact
embed. Into substrate w/ min 2 1/2' edge distance. Locate anchors
as shown in
(+33 ) / ( 41 )
(+48.2 ) / ( 48.2 )
installation details.
1/4" concrete screw 6" edge distance @ head, 4" edge distance
@ jamb, 4" each sid@
of transom centerline to bucking. Fastener spacing @ 15" o/c max.
@ head and jamb,
FL20461.17
R6
12/31/2021
Opaque single
Smooth Star
Therfna-Tru
N/A
Min. embedment of all anchors to be 1 1/4"
(+36) / (-47)
(+47) / (-47)
door with transom
Clopay
FL16107.3
R13 (R14)
12/31/2038,
Double Garage
16.2x7 73 W6
N/A
3/8" x 2-3/4" Hilti sleeve anchors 6" from ends 22" O/C
"
(+29) / (-35)
(+36) / (-42)
PENDING APPROVAL
Door
3/8" Simpson Titen heavy duty screw anchor with 1 1/8" OD washer into grout filled
CMU with min. emben of 2 3/4", min. edge distance of 4" and min. end distance of 4".
Double Garage
Max fastener spacing of 20". 3/8" dia. X 3" long lag screws with 1" OD washers with a
FL8248.11
R20
12/31/2023
Door (ALT)
8024
Wayne Dalton
N/A
1 9/32' thread penetration into seasoned dry wood supporting structure.
(+29) / (-35)
(+34.4)./ (-38.3)
3/8" Simpson Titen heavy duty screw anchor with 2 3/4" embed min 6" between jamb
FL14170.7
R14 (R15)
12/G 3,
Double Garage
Series 170-175, 177, 180-
Overhead
N/A
and bracket location. 2 3/4" min edge distance.
g
+29 35
( ) / (- )
+34.4
( ) / (-38.3)
APPROVAL)
(PENDING APPROVAL)
Door (ALT)
185, 187
Use galvanized (zinc coated) roofing nails, 11 or 12 gauge, with at least 3/8" dia.
heads, long enough to penetrate through plywood or 3/4" into boards. Use 4 nails per
shingle placed 6-1/8" above the butt edge, approx 1" and 13" from each end and 1/2"
FL30310.1
R1
12/31/2024
Roof
IKO SHINGLES
IKO Ctambridge
N/A
above each cutout. Drive nails straight so that nail head is flush with, but not cutting
N/A
N/A
into shingle surface.
Miami -Dade approved corrosion risistant tin caps and 12 ga. 1-114" annular ring
shank nails spaced 6"O.C. at all laps and three staggard rows fastened 12" O.C. in the
field.
FL15216.1
R8
12/31/2023
Underlayment
RhinoRoof U20
Interwrap
N/A
FL5259.1
R32
12/23/2023
Underlayment
Polystick IRXE
Polyglass USA
N/A
Self adhesive
(Alternate)
FL17322.1
R7
12/31/2024
Underlayment
(Alternate)
WeatherMasterl0o
n
AtlasRoofingCorp
N/A
Self adhesive
FL34546.1
R1
12/31/2024
Underlayment
Shield Granulated
Owens Corning
N/A
Self adhesive -
(Alternate)
FL27076.16
R1
3/28/2023
Underlayment
Weather Armor SB 1
APOC
N/A
Self adhesive
(Alternate)
FL3792.5
R14
8/16J2021
Off Ridge Vent
770D
Lomanaco
N/A
i d drequirements.
f per manufacturers recommended
InstallN/A
N/A
FL19567.2
R2
9/21/2026
Off Ridge Vent
MMI
MILLINUM METALS
N/A
Install per manufacturers recommended requirements.
N/A
N/A
(ALTERNATE)
FL33919.1
R1
12/31/2024
Soffit
Variform Soffits
PlyGem
N/A
Install per manufacturers recommended requirements.
(+31.6) / (-38.8)
(+157) / (-46.1)
12/31/2023,
Install per manufacturers recommended requirements.
FL15272.1
R4 (RS)
Soffit (Alt)
T2
Alside
N/A
(+31.6) / (-38.8)
(+75) / (-75)
(APPROVAL PENDING)
1/4" x 20 stainless steel or ELCO panelmate with minimum embedment @ 1 3/4" in
FL16293.1
R3
12/31/2021
Hurricane Panels
24 GAGE
Hurricane Storm
N/A
concrete / masonry, 2 1/2" min. edge distance, 12" o/c max. spacing. Can be headed
N/A
(+47) / (-53)
Less than 6' span
P
panel MFG.
screw or all thread but with wing nuts.
1/4" x 20 stainless steel or ELCO Panelmate with minimum embedment @ 13/4" in
FL16293.1
R3
12/31/2021
Hurricane Panels
24 GAGE
Hurricane Storm
N/A
concrete / masonry, 2 1/2" min. edge distance, 12" o/c max. spacing. Can be headed
N/A
(+45) J (-50)
6' span or more
panel MFG.
screw or all thread but with wing nuts.
FL17147.1
RS
6/27/2021
Zip System
Wall Sheathing
Huber
N/A
Install per manufacturers recommended requirements.
N/A
N/A
Sheathing
JarO@s Hardie
Install per manufacturers recommended requirements.
FL13192,2
R6
12/31/2023
Lap Siding
Cemplank
Buildili@ Products,
N/A
Inc
EgR-1336
_
FL1392.1
R7
1/1/2055
I Joists (2 Story
BCI
N/A
Install per manufacturers recommended requirements.
Only)
SUHDIV. 8e LOT:
ST L CIE
COUNTY
MASTER PA
PROJECT#
MODEL:
EXPRESS
SHINGLE
GARAGE SWING:
PAGE:
160 MPH EXP. C
EMEMMEROOF
ARCHITECT:
ATE OF FLORIDA,
t
APR 16 2021
MICHAEL C. ANDERSON
AR NO 17305
PRINT 03.30.21
DATE: _
SCALE: 1/4"=1'-0"
SHEET
P AI
FILE COPY
CONTROL DATE 33021