Loading...
HomeMy WebLinkAboutBUILDING PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date Permit Number: �uur o ¢.. A°�� M- � ROF6 Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial Residential x 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT APPLICATION FOR: PROPOSED IMPROVEMENT LOCATION: Address: 7924 Saddlebrook Dr. Port St Lucie FL 34986 Property Tax ID #: _ 3321-502-0040-000-8 Lot No. 91 Site Plan Name: Oliveira Residence - Water Heater Replacement Block No. Project Name: Oliveira Residence - Water Heater Replacement Water heater replacement - 50 gallon A.o smith hybrid, 2 gallon expansion tank, 3/4 ball valve, hardwire unit to switch with new whip, core drill 1 inch hole through cbs wall to run 3/4 condensate drain for unit. 22 inch pan New Electrical Meter Second Electrical Meter Additional work to be performed under this permit — check all that apply: _Mechanical _ Gas Tank —Gas Piping _ Shutters _Electric x Plumbing _Sprinklers Total Sq. Ft of Construction: Cost of Construction: $ 3,164.75 (Affidavit required) _ Windows/Doors _ Pond _ Generator _ Roof Pitch Sq. Ft. of First Floor: Utilities: —Sewer —Septic Building Height: OWNERAESS'EE: CONTRACTOR: Name Mario De Olivira Name: Paul Cloutier Address: 7924 Saddlebrook Dr Company: FPL Home Services City: Port St I ucie State: _F_L. Zip Code: 349A6 Fax: Phone No. (904) 563-5873 Address: 6001 Village Blvd City: _ West Palm Reaoh Stater Zip Code: 33407 Fax: Phone No561-747-5740 E-Mail: entropycap@aol.com Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail iordana.whitter(dfpl.com _ State or County License CFC1430331 If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION. DESIGNER/ENGINEER: Name: _ Not Applicable MORTGAGE COMPANY: Name: _ Not Applicable _ Address: Address: City: Zip: Phone State: City: Zip: _State: Phone: FEE SIMPLE TITLE Name. HOLDER. _ Not Applicable BONDING COMPANY. Name: Not Applicable Address: Address: City: city: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to youq property. A Notice of Commencement must be recorded in the public records of St. Luci ountygd post d on the jobsite before the first inspection. If you intend to obtain financing, consult wi I ndbr o n attorne03efare commencing work or recording your Notice of Commencement. of O�lvner/ Lessee/Contractor as Agent for Owner STATE OF FLORIDA COUNTY OF �" �f,l Q, Sworn to (or affirmed) and subscribed before me of Physical Presence or Online Notarization this 41.16. day of 20r9�1 by Paul Cloutier Name of person making statement. Personally Knowny OR Produced Identification Type of Identification Prodycgd Commission No. REVIEWS RECEIVED DATE COMPLETED Public- State of Florida ) (Seal) FRONT ZONING COUNTER REVIEW ��%� J�a W1rt{er of Fbride y caF, jrExpkft H5 078497 SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE REVIEW REVIEW REVIEW REVIEW REVIEW FPL Home Services 7830 Byron Drive #7 Riviera Beach, FL 33404 Billing Address Mario De Olivira 7924 Saddlebrook Drive Port St. Lucie, FL 34986 USA ***Need to replace 245 AMP Breakers Square D Task # Description I.BR00.0..55295 Bryant- 4 Ton, 16 SEER/ EER - 46.5 BTU AHRI: " Condensing Unit Model: BA16NA04800G • Breaker Size: 40 • Unit Height: 39.125 • Unit WidthL 35 • Unit Depth: 35 Air Handler Model: FX4DNF049L00 • Unit Height: 22 1/16 • Unit Width: 53 7/16 • Unit Depth: 2411/16 Invoice 96622969 Invoice Date 7/12/2021 Completed Date Customer PO Payment Term Due Upon Receipt Job Address Mario De Olivira 7924 Saddlebrook Drive Port St. Lucie, FL 34986 USA Quantity Your Price Your Total 2.00 $6,219.05 $12,438.10 The sale price includes the $0.00 FPL Rebate off of the original price. AOOO.T99404 Green UV Single Bulb 4.00 $560.00 $2,240.00 Protects your home by destroying germs and bacteria with the use of UV light that deactivates the DNA and killing on contact. 100% non chemical free with no harsh by- products. A000.T19925 To break up existing slab and replace with a new slab in order to pass permit inspection. 1.00 $249000 $249.00 A000.T19905 to re -insulate stand with new duct board and seal with mastic. 1900 $129.00 $129600 GOLD - NO GOLD - No Charge - As a Gold Club Member, you are guaranteed appointments within 24 2000 $0.00 $0.00 CHARGE hours, $39.00 evaluation fee, and a 15% parts discount and 2 tune-ups. AI00-1)500 $500 FPLHS Equipment Discount 3.00 $-500.00 $-1,500.00 Paid On Type Memo Amount 7/12/2021 Synchrony $13,556410 Sub -Total $13,556.10 Tax $0.00 Total Due $13,556.10 Payment $13,556.10 Balance Due $0.00 Please mail all payments to FPL Home Services 7830 Byron Drive #7 Riviera Beach, FL 33404 7/12/2021 By signing this acknowledgement, (certify that the work performed by HOUSE SALES at Mario De Olivira, for the amount of $13,556.10 has been completed. 7/12/2021 Payment Due: 7/8/2021 Mario De Olivira 7924 Saddlebrook Drive Port St. Lucie, FL 34986 USA Please pay total due amount. Thank you. Account#:194645956 Payment Type Credit Card # EXP CVC Name on card Signature Remit To: Amount Due: $0.00 6 0 (CA 1III I 11,1 i RESIDENTIAL ELECTRIC WATER HEATERS VOLTEX® HYBRID ELECTRIC HEAT PUMP WATER HEATER The Voltex Hybrid Electric heat pump water heater from A. 0. Smith is the most cost effective energy -efficient option available for consumers who want to save money on their utility bills. Voltex can reduce water heating costs up to 73% and provide payback in 2-3 years. With annual savings of $305 or more, there is no better way to go green than Voltex. HOW DO THEY WORK? Absorb ambient heat from the surrounding air to heat water using a compressor and "Environmentally -Friendly" R134a refrigerant • Self-contained heat pump unit is integrated into the top of the tank • Multiple operating modes to maximize efficiency and performance QUALIFIES FOR MANY STATE AND LOCAL UTILITY REBATES - CHECK WWW.DSIREUSA.ORG INCREASED ENERGY EFFICIENCY • Improved efficiency designed in, to ensure available hot water at the lowest possible cost. Up to a 3.45 Uniform Energy Factor (UEF) Rating conserves energy and meets ENERGY STAR® qualifications CHOICE OF OPERATING MODES • Select from Efficiency, Hybrid, or Electric modes to match heating requirements to environmental conditions. • Hybrid mode automatically adjusts between compressor and element, depending upon heat requirements. • Vacation mode reduces operating costs and provides freeze protection during extended absence BACKUP ELECTRIC ELEMENTS • Long-lasting backup heating elements help heat water according to environmental conditions, demand, and the chosen operating mode COREGARD'"ANODE ROD • Our anode rods have a stainless steel core that extends the life of the anode rod allowing superior tank protection far longer than standard anode rods • 66 and 80 gallon models have dual anodes for added protection. DRY FIRE PROTECTION • Control system checks to ensure the tank is full of water during start up to prevent dry firing the heating elements ELECTRONIC USER INTERFACE • User-friendly electronic interface all easy control of temperature setting, operating mode, and communicates diagnostics • Easy to read temperature display (see back) shows temperature in °For °C • Advanced diagnostics convey error messages for service purposes. The last four error messages are saved in the control system memory. • Ideal for basements or garage installations; the compressor transfers heat to the water while dehumidifying and cooling the ambient air • Washable air filter is easily removed for routine cleaning OPTIONAL AIR DUCT ADAPTER KIT • Permits installation in confined spaces SIX YEAR LIMITED WARRANTY • For complete information, consult written warranty or go to hotwater.com ENERGYSTAR t ©April 2019A. 0. Smith Corporation. All Rights Reserved Page i of 2 www.hotwater.com 1800.527.1953 Toll -Free USASmith Corporation 1500 Tennessee Waltz Parkway I Ashland City, TN 37015 AOSXE50006 RESIDENTIAL ELECTRIC WATER HEATERS Model Number Nominal ! Capacity Rated Storage Volume UEF First Hour Rating (Gallons) Dimensions in inches Approx. Shippingg Weight (Ibs) Warranty Term A 0 C D E FPTU-50 50 46 3.42 66 63 22 40-5/8 3-3/4 40-1/2 196 6 FPTU-66 66 67 1 3.35 79 61 27 38 4 38 289 6 FPTU-80 80 82 3.45 84 69 27 46 4 46 307 6 Requires 30 amp breaker. Top T&P option not available. ELECTRONIC USER INTERFACE • User friendly, easy to read display. • LEDs clearly indicate the current operating mode. • Easily select operating mode: • Efficiency • Hybrid • Electric • Vacation • Display communicates current status, mode and set point, and displays error messages when applicable. EFFICIENCY MODE • Utilizes the heat pump for all water heating. • Automatically reverts to heating element if ambient air or water temperatures are outside optimal operating range for heat pump. HYBRID MODE • Utilizes the heat pump or heating element, depending on demand. ELECTRIC MODE • Standard electric water heater operation. VACATION MODE • One touch operation maintains tank temperature of 600F (15.6°C) during vacation or extended absence to reduce operating costs and provide freeze protection. • Programmable up to 99 days. OTHER FEATURES: • Sacrificial anode to protect against tank corrosion. • Environmentally -friendly non-CFC foam insulation, • Durable, enhanced -flow brass drain valve. • CSA certified and ASME rated temperature & pressure relief valve. OPERATING REQUIREMENTS: • Requires provision for condensate draining; if a suitable drain is not available, a condensate pump is required. • 208/240 VAC 601-Iz single phase 30 amp power supply. ©April 2019A.0. Smith Corporation. All Rights Reserved Page 2 of 2 www.hotwater.com i 800.527-1953 Toll -Free USA i A. 0. Smith Corporation 1500 Tennessee Waltz Parkway i Ashland City, TN 37015 AOSXE50006