HomeMy WebLinkAboutRISER DIAGRAM Sheet9 OWNER: Darlene Tierney RISER DIAGRAM DATE: 08/02/21 50A Portable Generator hook up 4DDRESS: 201 Riverwalk Fort Pierce FI.34949 CONTRACTOR: VLS ELECTRICAL Existing FPL Meter to Remain Existing panel in garage with new Generator Interlock Device and 50A Generator input breaker 0 Existing conduit and feeder wires to remain New 3/4"pvc Conduit with 348 wires+#10G New PB50 Generator inlet box I Page 1 en 0C co Model GE-200HDA MaYn Bremer 150 or 200 amp single handle Vertical throw up (on) down (off) Spacing between main and the first breaker is 2 '/4 inches 6euerator:Breaker: Top left side 2 positions a S R� y y Only qualified personnel should be working on the panel box An amateur should NEVER open the panel box Please follow all rules and regulations of the National Electric Code Step 1: Disassemble the interlock.Place the bottom plate(holes only)above the top left breaker and mark holes. Step 2: Turn off main breaker and remove panel cover. Step 3: Drill holes as marked on panel cover with supplied 3/16 drill bit and remove all burs from drilling cover. Step 4: Insert screws from rear of cover,install bottom plate,and install top plate(slotted)install thread lock to screws and install retaining nuts.Ensure proper movement. Step 5: Install 2 pole Generator breaker on top left side and place Generator Warning Sticker on Generator breaker. Step 6: Combine the zip ties to make a loop and install zip ties around top set of breakers in panel as shown in picture below.Pull on ends to make tight around breakers.Trim zip ties as needed and Install Warning label next to release tab on zip tie at generator breaker. i p Step 7: Re-Install panel cover,Verify proper operation of interlock.Main breaker ON,generator breaker OFF and generator breaker CAN NOT be turned on. Generator breaker ON,main breaker OFF and main breaker CAN NOT be turned on. a Generator on Main On Step 8: Place Generator start-up procedure label on panel box,Place CAUTION label on panel box and electric meter pan. The`11%IAIN and theENERATUR U�real�ersYshould NEU1R be able'to be tuned at the same timefpariel= suer isxemoed the ex� xatorbreakers NR,to be turned an If for any reason the interlock does not function properly,DO NOT USE'and contact us immediately at sales(@GenInterlock.com for support and instructions. Thank You for your support, GenInterlock Team GenInterlock.com is NOT responsible for misuse or improper installation. All electrical equipment should be installed and maintained by qualified personnel. Any consequences arising from improper use is the responsibility of the user. GenInterlock.com Sales(a,geninterlock.com 732-339-4191 i POWER INLET BOX p CAT. NO. PB50: d 50 Amps., 120/240 VAC , • , INSTALLATION - • IMPORTANT: Installation of this power inlet box and related wiring must be done by a qualified electrician in compliance with all applicable electrical codes. When used to power a structure,this inlet must be used in conjunction with a transfer switch. Not for indoor use. When using an engine driven generator, locate away from doors and windows to avoid the build-up of carbon monoxide from the engine exhaust in enclosed areas. INSTALLING A REMOTELY LOCATED POWER INLET BOX FOR SUPPLYING POWER TO THE POWER INLET OF OR PANEL Installing the Power Inlet Box Mount the power inlet box on the outside of the building in a convenient location, using the three holes provided in the back of the cabinet. Using copper wire only and approved wiring methods, run the wiring through one of the knockouts in the cabinet to a junction box located near the transfer switch. If using conduit, pull at least three color- coded wires (AWG #8 minimum, AWG #4 maximum) -- use white for neutral, and two other distinguishing colors (typically black.and red) for the 240V line. If not using conduit or if otherwise required, include a green wire as a separate ground wire.. Strip the wire insulation-5/8" (do not tin conductors) and connect the wires in the power inlet box as follows making sure there is no wire insulation in any terminal and the inlet terminal screws are tightened to 35 inch-pounds torque using a 5/32 Allen wrench: 240 Volt line wires to the brass terminals marked"X"and"Y". White wire to the nickel-plated neutral terminal marked"W" Green power inlet wire to green ground screw terminal on inside of cabinet. If required,green wire to green ground screw terminal on inside of cabinet. Installing a junction box and cord connector The cord assembly from the junction box to the transfer switch power inlet is to be made of four-conductor cord suitable for a 50 Amp. load. The insulation on each of the wires is colored to identify with the standardized coding in plugs and receptacles. Wire colors are usually white, green,black, and red. One end of the.cord will be connected to the wires in the junction box, and the opposite end will be connected to a Type CS-6364N (such as the Reliance Cat. No. LL550C)connector which will mate with the power inlet on the face of the transfer switch. Remove one junction box knockout and insert a cord grip and the cord. Connect the wires in the junction box as follows: Red and black cord wires to 240V line wires from the power inlet box. White cord wire to the white neutral wire from the power inlet box. Green cord wire to junction box ground screw. Green wire from power inlet box, if required,to junction box ground screw. Following the wiring device manufacturer's instructions,wire the CS-6364N connector as follows: Red and black wires to the brass terminals marked"X" and"Y". White wire to the nickel-plated neutral terminal marked"W". Green wire to the green ground terminal.marked"G". A diagram of the above arrangement is shown below. It is not necessary to detach the connector from the swtich or panel when generator is not in use, and for convenience may be left in place at all times. INSTALLING A REMOTELY LOCATED POWER INLET BOX FOR CONNECTION DIRECTLY TO A ' HARD-WIRE TRANSFER SWITCH OR PANEL: Installation will generally be as described above, except that the wiring can be run directly to the transfer switch or panel. Wire connections are to be made at the transfer switch or panel according to manufacturer's instructions. PREPARING A CORD FROM THE GENERATOR TO THE POWER INLET BOX: Using a 4-conductor 50 Amp. portable cord suitable for the purpose, attach a male plug matching the configuration of the generator outlet to one end, and a Type CS-6364N connector (which will mate with the power inlet in the power inlet box)to the opposite end. Following the wiring device manufacturer's instructions, wire the generator plug and the CS-6364N connector as follows: Red and black wires to the brass terminals marked"V and"Y". White wire to the nickel-plated neutral terminal marked"W". Green wire to the green ground terminal marked "G". AL7ERNA'7MME!N5TA!(M W4 MAN5FER FOR RELIANCE PRO11RAN MOO ELS 5K7TGN' 000000 314^C0NVLil'r POWER INLEtBOX. JUNCTION'60X. TRANSFER BREAItER.PANE'L BWITCH ;j o00000 OENERArOR w, p: 3/4"GONI 4 CONDUCTOR CABLE: 45,N6364N.. CONECTOR RELIANCE CONTROLS CORPORATION /2001 YOUNG COURT/ RACINE, WI 53404/ (262) 634-6155 9-8-14