Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PHOTOVOLTAIC SYSTEM
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY HARTLAUB, VICKIE KIMANDY LAWRENCE,PE ON THE DATE ADJACENT TO THE SEAL.PRINTED COPIES OF THIS DOCUMENT ARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE NEW GRID-INTERACTIVE PHOTOVOLTAIC SYSTEM � LORD&LAWRENCE DC SYSTEM SIZE (4.455KW) MUST BE VERIFIED ON ANY ELECTRONIC COPIES. =CONSULTING ENGINEERS CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA FLORIDA REGISTRY#83317 GENERAL NOTES SYSTEM DETAILS SITE MAP (N.T.S) SCOPE OF WORK EQUIPMENT DESCRIPTION NEW GRID-INTERACTIVE PHOTOVOLTAIC 1. THE PROJECT IS NEW PHOTOVOLTAIC SYSTEM CONSISTING OF SOLAR 1. ALL ELECTRICAL COMPONENTS INSTALLED OUTDOORS,EXPOSED TO SYSTEM WITH NO BATTERY STORAGE ARRAY(S)AND ASSOCIATED POWER CONDITIONING EQUIPMENT. WEATHER OR IN DAMP LOCATIONS SHALL BE RATED FOR NEMA 3R OR GREATER. = UrbanSolar. 2. ALL CONSTRUCTION SHALL COMPLY WITH THE ADOPTED EDITION OF THE INSTALLATION OF THESE COMPONENTS MUST COMPLY WITH THE DC RATING OF SYSTEM SYSTEM SIZE:4.455KW DC STC INTERNATIONAL BUILDING CODE AND ELECTRIC CODE AS SPECIFIED IN THE PROJECT MANUFACTURER'S INSTALLATION INSTRUCTIONS. SPECIFIC NOTES. 2. ALL RACEWAYS,CABINETS,BOXES,FIXTURES SHALL BE SUPPORTED - 3. IT SHALL ALSO COMPLY WITH ALL APPLICABLE CITY,COUNTY,STATE AND FROM THE BUILDING STRUCTURE IN AN APPROVED MANNER. AC RATING OF SYSTEM 3.19KW LOCAL ELECTRICAL UTILITY CODES,RULES AND REGULATIONS. CONTACT:561-609-2664 3. AT THE COMPLETION OF THE PROJECT NEATLY TYPED ACCURATE 4. THE SYSTEM WILL BE INTERCONNECTED TO THE ELECTRICAL UTILITY E - 990 SOUTH ROGERS CIRCLE SUITE 4 GRID IN ACCORDANCE WITH THE REQUIREMENTS OF THE ADOPTED ELECTRIC AND THE PANEL BOARD DIRECTORIES INDICATING ALL BRANCH CIRCUITS AND SPARES WILL MAX.AC OUT.CURRENT 13.31 A - BOLA BATON,FL ELECTRICAL UTILITY COMPANY. BE PROVIDED.ALL SPARES SHALL BE LEFT IN THE OFF POSITION. SOLAR CONTRACTOR LICENSE:NSE:CVC56948 5. THE CONTRACTOR SHALL PROVIDE LABOR FOR CONSTRUCTION OF THE 4. ALL SAFETY SWITCHES SHALL BE HEAVY DUTY TYPE WITH COVER ARRAY AND INSTALLATION OF ALL ELECTRICAL EQUIPMENT.THE CONTRACTOR WILL INTERLOCK AND HANDLE LOCK OFF PROVISIONS.SWITCHES SHALL BE NO.OF MODULES (11) JKM405M-72HL-V G2(405W)JINKO SOLAR r PROVIDE COMPETENT SUPERVISION FOR THE WORK TO BE ACCOMPLISHED. MANUFACTURED BY A COMPANY CONSISTENT WITH OTHER INSTALLED EQUIPMENT WHENEVER POSSIBLE.PART NUMBERS,RATING AND FUSING SHALL BE AS SHOWN NO.OF INVERTERS ( ) CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL BY OWNER AS 11 ENPHASE IQ7PLUS-72-2-US ON THE DRAWINGS. REQUESTED. MICROINVERTERS 6. THERE WILL BE NO SUBMISSION FOR ANY EQUIPMENT WITH THE VENDOR 5. CONTRACTOR SHALL ENSURE ALL CEC AND MAINTENANCE PART NUMBER ON THE DRAWING WITHOUT WRITTEN APPROVAL OF THE PROFESSIONAL CLEARANCE REQUIREMENTS ARE MET FOR NEW EQUIPMENT AND MAINTAINED FOR POINT OF CONNECTION LINE SIDE TAP ENGINEER.COMMON ITEMS SUCH AS CONDUITS,WIRE,FITTINGS,ETC.ARE NOT EXISTING EQUIPMENT. -�- SPECIFIED BY VENDOR BUT THE SIZES CANNOT BE REDUCED. 6. CONTRACTOR SHALL FIELD VERIFY EQUIPMENT CLEARANCE AND LO 7. THE CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS AGREE PLACEMENTS WHILE COORDINATING LOCATORS WITH ARRAY STRINGING (1)BRANCH OF 11 MODULES C' W 0 THAT IN ACCORDANCE WITH THE GENERALLY ACCEPTED CONSTRUCTION PRACTICES OTHER TRADES,CONSTRUCTION MANAGERS,AND SITE SUPERVISORS PRIOR TO r' ------ Q -'t CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS WILL BE REQUIRED TO PURCHASING AND INSTALLING EQUIPMENT. v,,1 O Co COMPLETEASSUME SOLE AND PROPER Y,AND THATHIS REQUIREMENT SHALL BE MADE TO APPLY CONTINUOUS Y NONSTRUCTURAL COM ONEN T PORTION S THAT REPERMANENTTLY ATTACHED TO 1U-I iL AND IS NOT LIMITED TO NORMAL WORKING HOURS. STRUCTURES AND THEIR SUPPORTS AND ATTACHMENTS,SHALL BE DESIGNED AND SITE DETAILS M C) 8. CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS FURTHER CONSTRUCTED TO RESIST THE EFFECTS OF EARTHQUAKE MOTIONS IN VICINITY MAP > (If LLI Op AGREE TO DEFEND,INDEMNIFY AND HOLD HARMLESS THE DESIGN PROFESSIONAL ACCORDANCE WITH ASCE 7,EXCLUDING CHAPTER 14 AND APPENDIX ASHRAE EXTREME LOW 0°C M.�wa Q U FROM ANY AND ALL LIABILITY,REAL OR ALLEGED,IN CONNECTION WITH THE 11A.THE SEISMIC DESIGN CATEGORY FOR A STRUCTURE IS PERMITTED TO BE PERFORMANCE OF WORK ON THIS PROJECT,EXCEPT LIABILITY ARISING FROM THE DETERMINED IN ACCORDANCE WITH SECTION 1613 OR ASCE 7. ASHRAE 2%HIGH 33°C Q w SOLE NEGLIGENCE OF THE DESIGN PERSONNEL. 8. ALL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE Fon waimnA- T GROUND SNOW LOAD 0 PSF CO _ LQ 9. CONSTRUCTION CONTRACTOR AND HIS SUBCONTRACTORS WILL BE OCCUPANT OF THE ROOM OR AREA TO CONTROL 1.4 0- L{") REQUIRE TO REPAIR ANY DAMAGE DONE TO BUILDINGS,GROUNDS OR UTILITIES AT NO LIGHTING AND RECEPTACLE OUTLETS,APPLIANCE AND COOLING,HEATING AN D WIND SPEED 160 MPH(ASCE 7-16) Doaao n° F_ T_ 't ADDITIONAL COST TO THE CUSTOMER.DEFECTIVE MATERIAL OR WORKMANSHIP WILL VENTILATING EQUIPMENT,SHALL BE LOCATED ,,,,,,/// O ~ LO NOT BE ALLOWED ON THIS PROJECT.RESONABLE HOUSEKEEPING AND CLEAN UP NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE JUNCTION OR DEVICE RISK CATEGORY II ° 3' CO 0-1 SHALL BE CONDUCTED BOTH DURING THE EXECUTION OF AND AT THE CONCLUSION OF BOX NOR LESS THAN 15 INCHES ° vyard em E. h-I ~ CV THE PROJECT. MEASURED TO THE BOTTOM OF THE JUNCTION OR DEVICE BOX ABOVE THE WIND EXPOSURE CATEGORY B �- a7601 Bayard Fort Pierce ` - LL FINISHED FLOOR. FL 34951.United States GENERAL 9. ALL RECEPTACLE OUTLETS ON BRANCH CIRCUITS OF 30-AMPERES OR Wt?,Q a�la A m 1. THE ACTUAL SYSTEM EQUIPMENT SPECIFICATIONS FOR THE LESS AND COMMUNICATION SYSTEM RECEPTACLES GOVERNING CODES c PHOTOVOLTAIC SYSTEM ARE INCLUDED IN THE PV SYSTEM SPECIFICATION ON THE SHALL BE LOCATED NO MORE THAN 48 INCHES MEASURED FROM THE TOP OF THE � TITLE PAGE AND THROUGHOUT THE DRAWING AS NECESSARY FOR CLARITY.IN Kpnw°°d Rd °""°° AcI RECEPTACLE OUTLET BOX OR RECEPTACLE FLORIDA RESIDENTIAL CODE,7TH EDITION 2020(FRC) 'y ADDITION THE ACTUAL VENDOR SPECIFICATION DATA SHEETS WILL BE INCLUDED AS HOUSING NOR LESS THAN 15 INCHES MEASURED TO THE BOTTOM OF THE PART OF THE PERMIT SUBMITTAL. RECEPTACLE OUTLET BOX OR RECEPTACLE HOUSING ABOVE FINISHED FLOOR. FLORIDA BUILDING CODE,7TH EDITION 2020(FBC) a° °n nd SIGNATURE WITH SEAL 2. ONLY NEW MATERIAL WILL BE INSTALLED AS PART OF THE PROJECT. ALL NEW INSTALLED EQUIPMENT WILL BE APPROPRIATELY LISTED AND NEMA RATED. GROUNDING FLORIDA FIRE PREVENTION CODE,7TH EDITION 2020(FFPC) HartilionAJpz` = 1(LA ALL NEW EQUIPMENT SHALL HAVE PERMANENT PLASTIC ENGRAVED IDENTIFICATION 1. THE GROUNDING SYSTEM SHALL MEET THE REQUIREMENTS OF THE 'VV, NATIONAL ELECTRIC CODE,NEC 2017 CODE BOOK TAGS INSTALLED. NEC AND THE LOCAL ADOPTED CODE.ALL ELECTRICAL EQUIPMENT AND RACEWAYSu - 3. ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF NEW _ No.83317 m RACEWAYS AND EQUIPMENT SHALL BE RESPONSIBILITY OF THE ELECTRICAL SHALL BE PROPERLY GROUNDED. H°E°vao A p Hlbl:Ns en z Hibi. 2. AN INSULATED EQUIPMENT GROUNDING CONDUCTOR,IN SHEET INDEX CONTRACTOR.ALL WORK SHALL BE PERFORMED BY TRADESMAN ACCORDANCE WITH NEC CODE,SHALL BE PROVIDED IN ALL CONDUITS WITH EXPERIENCED IN WORK REQUIRED.ALL FINISHES SHALL MATCH THE EXISTING CURRENT CARRYING CONDUCTORS.ALL LUGS AND CONNECTORS SHALL BE RATED �O STATE OF t� ADJACENT FINISHES.OPENING IN FIRE RATED WALLS WILL BE PATCHED IN A SHEET NO. SHEET NAME '��` °FOR... FOR THE CONDUCTOR MATERIAL AND THE CONDITIONS OF USE. ''"SSA" "�� , MANNER MAINTAINING THE ORIGINAL FIRE AND SMOKE RATING. ONAL 3. THE GROUNDING RESISTIVITY WILL BE TESTED AFTER INSTALLATION PV-1 COVER PAGE 'iirrriiiirr��� 4. DRAWINGS ARE DIAGRAMMATIC IN NATURE AND CANNOT SHOW EVERY TO CONFIRM 5 OHM OR LESS RESISTANCE FROM RACKING TO GROUND.IF GROUND WIND FLOW MAP CONNECTION,JUNCTION BOX,WIRE,CONDUIT, RESISTANCE IS GREATER THAN 5 OHMS ADDITIONAL GROUNDING WILL BE PV-2 FIRE SAFETY PLAN Digitally signed ETC. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING A COMPLETE AND INSTALLED UNTIL RESISTANCE IS LESS THAN 5 OHMS. PV-3 ELECTRICAL LINE DIAGRAM m I I FUNCTIONAL ELECTRICAL SYSTEM. ® by Kimandy 5. CONTRACTOR SHALL COORDINATE ALL POWER OUTAGES WITH THE PV-4 ELECTRICAL CALCULATIONS °°oe a=n OWNER'S REPRESENTATIVE IN ADVANCE. WIRING DEVICES Lawrence 6. PANEL DESIGNATIONS SHOWN ON THESE DRAWINGS ARE GIVEN FOR 1. RECEPTACLES SHALL BE AS DESIGNED ON THE DRAWINGS AND PV-5 LABELS Orlando CLARIFICATION OF THE CIRCUITING ONLY AND MAY SHOULD BE A BRAND CONSISTENT WITH OTHERS IN THE VICINITY WHENEVER Date: 2021.08.03 NOT CORRESPOND TO THE DESIGNATIONS FOUND IN THE FIELD. PV-6 RACKING LAYOUT 7. ELECTRICAL TESTING SHALL BE IN COMPLIANCE WITH NFPA 70E POSSIBLE. Ta a o K e h,e 22h ' 2. ALL WIRING DEVICES SHALL BE PROVIDED WITH APPROPRIATE PV-7 STRUCTURAL DETAILS ciaar�,aver.° ° 15:10:43 -04 00 COVER-PLATES.ANY EMPTY BOXES SHALL HAVE BLANK PetersBur FLC R I D A �n CONDUIT AND WIRE COVER PLATES.COVER-PLATES SHALL BE LEXAN,PLASTIC OR STAINLESS STEEL IN PV-8 MODULE DATASHEET 1. ALL EXISTING CONDUIT RUNS ARE NOT SHOWN.CONTRACTOR SHALL FINISHED AREA.GALVANIZED COVER-PLATES MAY BE USED IN EQUIPMENT ROOMS. VERIFY EXISTING CONDUIT LOCATIONS IN FIELD. PV-9 INVERTER DATASHEET PERMIT DEVELOPER 2. ALL CONDUCTORS SHALL BE INSTALLED IN A RACEWAY AS SPECIFIED est Alm LABELING AND PHASING ee cn IN THE DRAWINGS.THE EXCEPTION IS PV SOURCE CIRCUIT CONDUCTORS MADE 1. FOR LABELING USE NUMBERED UV RATED LABELS TO INDICATE PV-10 JUNCTION BOX DATASHEET Fon° rs OF PV WIRE CABLE.THESE CONDUCTORS MAY BE EXPOSED WITHIN THE PV ARRAY. STRING NUMBER. PV-11 COMBINER PANEL DATASHEET DATE 07/24/2021 3. INDOOR EMT FITTINGS MAY BE COMPRESSION TYPE OR STEEL SET 2. AS A SUBSTITUTE FOR LABELS YELLOW TAPE MAY BE USED FOR ® udo ale SCREW TYPE.OUTDOOR EMT FITTINGS MUST BE COMPRESSION RAINTIGHT TYPE. PHASING PV-12 RACKING DATASHEET Mia i DESIGNER OPS 4. A PULL ROPE SHALL BE INSTALLED IN ALL EMPTY CONDUITS. 3. EACH METHOD DESCRIBED ABOVE WILL NEED TO BE PERFORMED ON 5. CONDUCTORS MATERIAL,EITHER COPPER OR ALUMINUM IN BOTH POSITIVE AND NEGATIVE AT POINTS WHERE PV-13 ATTACHMENT DATASHEET SPECIFIED IN THE DRAWINGS.CONDUCTOR INSULATION TYPE SHALL BE THWN-2 CONDUCTORS ARE TERMINATED ever FREVIEWER UNLESS OTHERWISE NOTED. PV-14 SEALANT DATASHEET nal Park PV-15 GROUNDING&BONDING DATASHEET Dab COVER PAGE we ^` '-1 LORD&LAWRENCE sp, CONSULTING ENGINEERS CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA FLORIDA REGISTRY#83317 18" SETBACK UrhanSolar CONDUIT RUN CONTACi:561-609-2664 990 SOUTH ROGERS CIRCLE SUITE 4 (E)SERVICE DROP J6 O O O BOCA RATON,FL 33487 SOLAR CONTRACTOR LICENSE:CVC56948 ROOF ACCESS POINT 0 0 0 0 0 0 0 0 0 MSP W Q tcM (E)MAIN SERVICE PANEL UM ACID cP RAP v O J CD (INSIDE HOUSE) ROOF 1 ROOF ACCESS POINT 0 w CD 00 (E)UTILITY METER Q w Lo (OUTSIDE HOUSE) a a ��00 F_ It x c � � (N)AC DISCONNECT x ~ � N (FUSIBLE) (N)COMBINER PANEL SIGNATURE WITH SEAL EQUIPMENT SPECIFICATIONS NOTES: LEGENDS ROOF SPECIFICATIONS ROOF INFORMATION 1. LOCATION OF JUNCTION BOX ES , AC ( ) uM -UTILITY METER EQUIPMENT DESCRIPTION QUANTITY ROOF MATERIAL ASPHALT SHINGLE ROOF QUANTITY SLOPE AZIMUTH DISCONNECTS(S), AC COMBINER PANEL(S), MODULE JKM405M-72HL-V G2(405W)JINKO SOLAR 11 ROOF CONDITION GOOD ROOF 1 11 14.04°(3/12) 180° SP AND OTHER ELECTRICAL EQUIPMENT(S) M -MAIN SERVICE PANEL ENPHASEIO7PLUS-72-2-US RELEVANT TO PV INSTALLATION SUBJECT TO JB -JUNCTION BOX INVERTER MICROINVERTERS �� RAFTERS 2"X4°@24°o.c. CHANGE BASED ON SITE CONDITIONS. JUNCTION BOX SOLTECTION RJ-1 ROOFTOP 1 2. SETBACKS AT RIDGES CAN BE REDUCED TO AC DISCONNECT COMBINER PANEL 80AENPHASEIO COMBINER 3 1 18 INCHES IN COMPLIANCE WITH FBC R 324.6.2: CP -COMBINER PANEL PERMIT DEVELOPER AC DISCONNECT AC DISCONNECT 240V,30 AMP,WITH 1 SYSTEM INFORMATION TOTAL PLAN VIEW AREA= 2156 SQFT 20A FUSES,NEMA 3R,UL LISTED RAP - DATE 07/24/2021 DC SYSTEM SIZE 4.455KW TOTAL PV AREA= 11(79.06 IN)(39.45 IN)/(144 ❑ ROOF ACCESS POINT ATTACHMENT STRING TAG DESIGNER OPS QUICKMOUNT(L-MOUNT) 33 INA 2) 1❑ AC SYSTEM SIZE 3.19KW RACKING SYSTEM IRONRIDGE(XR100)RAILS _ = 238.25 SQFT CONDUIT RUN (238.25 SQFT/2156 SQFT)100 = 11.05 % FIRE SETBACK REVIEWER - TOTAL PV AREA POPULATES 11.05 % OF TOTAL O ❑ ROOF OBSTRUCTION FIRE SAFETY PLAN PLAN VIEW AREA AND IS WITHIN THE 33% REQUIREMENT. PV-2 CONDUCTOR AND CONDUIT SCHEDULE MODULE SPECIFICATION INVERTER SPECIFICATION ARRAY DETAILS '� �_LORD&LAWRENCE grac CONSULTING ENGINEERS SR.NO. DESCRIPTION CONDUIT SIZE MANUFACTURER JINKO SOLAR MANUFACTURER ENPHASE DC SYSTEM SIZE 4.455KW \�� MODEL NO. JKM 405M-72HL-V G2 MODEL NO. IQ7PLUS-72-2-US AC SYSTEM SIZE 3.19KW qO ENPHASE Q CABLES,(1)#10 AWG THWN-2(G) PEAK POWER(Pmpp) 405W MAX.DC INPUT VOLTAGE 60V TOTAL NO.OF MODULES 11 CONTACT:(561)4448192 5700 LAKE WORTH ROAD SUITE 211 O (1)#10 AWG THWN-2(L1),(1)#10 AWG THWN-2(1-2),(1)#10 AWG THWN-2(G) IN 3/4" CONDUIT RUN PEAK VOLTAGE(Vmpp) 40.42V MAX.CONT.OUTPUT POWER 290VA NO.OF MODULE PER STRING 1 @11 GREENACRES,FL 33463,USA FLORIDA REGISTRY#83317 O (3)#10 AWG THWN-2(1-1,1-2,N),(1)#10 AWG THWN-2(G) IN 3/4" CONDUIT RUN PEAK CURRENT(Impp) 10.02A NOMINAL AC OUTPUT VOLTAGE 240V NO.OF STRING 1 OPEN CIRCUIT VOLTAGE(Voc) I 49.4V MAX.CONT.OUTPUT CURRENT 1.21A O (3)#10 AWG THWN-2(1-1,1-2,N),(1)#10 AWG THWN-2(G) IN 3/4" CONDUIT RUN SHORT CIRCUIT CURRENT(Isc) 10.69A NOTE: ��•••��UrhanSolar. CONDUIT RUN-EMT,PVC, IMC,RMC,FMC,LFMC OR EQUIVALENT AS PER NEC CONTACT:S61-609-2664 990 SOUTH ROGERS CIRCLE SUITE 4 BOCA RATON,FL 33487 SOLAR CONTRACTOR LICENSE:CVC56948 (N)SOLTECTION JUNCTION BOX, (N) 80A ENPHASE NEMA 3R IQ AC COMBINER 120/240V NEMA 3R 200 A (E) MAIN SERVICE PANEL LINE SIDE TAP W ENVOY IQ 120/240V WITH INSULATION � Om � (N)30A AC DISCONNECT PIERCING 705.12(A) U J 0 LL 240V,FUSED WITH 20A FUSES 1 STRING OF 15A/2P NEMA 3R, UL LISTED Q U 00 11 MODULES WITH (E)150 A >- � MICROINVERTERS G \ 20A/2P �� a m LuLo 20A/2P 04 coo Lq ~ ~ A 1 ; x LL N UM G G i i SIGNATURE WITH SEAL • • NOTE: THE CIRCUIT BREAKER SHOWN FEEDING • • THE ENPHASE ENVOY IS FACTORY INSTALLED.THE SIZE OF THIS CIRCUIT BREAKER IS SUBJECT TO CHANGE BASED ON MANUFACTURER PREFERENCE IN < > ACCORDANCE WITH THE UL LISTING. 3 G N 2 PERMIT DEVELOPER DATE 07/24/2021 PER FL.STATUE 377.705(REVISED 7/1/2017)I, KIMANDY DESIGNER OPS LAWRENCE PE#83317,AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV REVIEWER ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS ELECTRICAL LINE DIAGRAM CONTAINED IN THE MOST RECENT VERSION OF THE PV-3 FLORIDA BUILDING CODE. GENERAL ELECTRICAL NOTES: ELECTRICAL CALCULATIONS: 1. THE DC AND AC CONNECTORS OF THE ENPHASE IQ7PLUS-72-2-US MICROINVERTERS ARE LISTED TO MEET LORD&LAWRENCE REQUIREMENTS AS A DISCONNECT MEANS AS ALLOWED BY NEC 690.15(A). CONSULTING ENGINEERS 1. CURRENT CARRYING CONDUCTOR 2. MICROINVERTER BRANCH CIRCUIT CONDUCTORS ARE MANUFACTURED ENPHASE Q CABLES LISTED FOR USE (A) BEFORE IQ COMBINER PANEL : IN 20A OR LESS CIRCUITS OF ENPHASE IQ MICROINVERTERS.THEY ARE ROHS,OIL RESISTANT,AND UV CONTACT:(561)4448192 RESISTANT.THEY CONTAIN AWG CONDUCTORS OF TYPE THHN/THWN-2 DRY/WET AND CERTIFIED TO UL3003 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA AMBIENT TEMPERATURE = 33'C AND UL 9703.THE CABLE'S DOUBLE INSULATED RATING REQUIRES NO NEUTRAL OR GROUNDED CONDUCTOR. FLORIDA REGISTRY#83317 CONDUIT INSTALLED AT MINIMUM DISTANCE OF 7/8 INCHES ABOVE ROOF .....NEC 310.15(B)(3)(C) 3. ALL METAL ENCLOSURES, RACEWAYS, CABLES AND EXPOSED NONCURRENT-CARRYING METAL PARTS OF EQUIPMENT SHALL BE GROUNDED TO EARTH AS REQUIRED BY NEC 250.4(B)AND PART III OF NEC ARTICLE 250 TEMPERATURE DERATE FACTOR- (0.96) ..............NEC 310.15(B)(2)(a) AND EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45.THE GROUNDING GROUPING FACTOR- (1) .................................NEC 310.15(B)(3)(a) ELECTRODE SYSTEM SHALL ADHERE TO 690.47(A). UrbanSolar CONDUCTOR AMPACITY: 4. PV SYSTEM DISCONNECT SHALL BE READILY ACCESSIBLE. CONTACT:561-609-2664 _ (INV O/P CURRENT )x 1.25/A.T.F/G.F ...NEC 690.8(B) 5. POINT-OF-CONNECTION SHALL BE MADE IN COMPLIANCE WITH NEC 705.12 990 SOUTH ROGERS CIRCLE SUITE4 BOCA RATON,FL 33487 = [(11 x 1.21)x 1.25]/0.96/ 1 SOLAR CONTRACTOR LICENSE:CVC56948 = 17.33 A 6. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. SELECTED CONDUCTOR-#10 THWN-2 ...NEC 310.15(B)(16) 7. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. MICROINVERTERS CONFORM TO AND ARE LISTED (B) AFTER IQ COMBINER PANEL: UNDER UL 1741 AND IEEE 1547. TEMPERATURE DERATE FACTOR- (0.96) 8. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER � co GROUPING FACTOR- (1) NEC ARTICLE 300.6(C)(1)AND ARTICLE 310.10(D). O M 9. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEC U LL CONDUCTOR AMPACITY _ li _ (TOTAL INV O/P CURRENT)x 1.25/0.96/ 1 ...NEC 690.8(B) ARTICLE 310.10(C). > � LU 00 _ [(11 x 1.21)x 1.251/0.96/ 1 10. ALL DC WIRING RUNNING THROUGH THE BUILDING SHALL BE ENCLOSED IN METALLIC CONDUIT IN GG } = 17.33 A COMPLIANCE WITH NEC 690.31(G).THIS REQUIREMENT SHALL APPLY TO OPTIMIZER-BASED SYSTEMS, BUT � Q [)f LU SELECTED CONDUCTOR-#10 THWN-2 ...NEC 310.15(B)(16) SHALL NOT APPLY TO MICROINVERTER-BASED SYSTEMS. a 00 a Lo 2. PV OVER CURRENT PROTECTION ...NEC 690.9(B) 11. A 10 AWG CU EQUIPMENT GROUNDING CONDUCTOR SHALL BE USED TO BOND RAILS AND OTHER ROOFTOP P4 � EQUIPMENT.THIS CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BY RUNNING UNDERNEATH �� ti O CV = TOTAL INVERTER O/P CURRENT x 1.25 THE ARRAY. IF THIS CONDUCTOR IS UNPROTECTED FROM PHYSICAL DAMAGE,THE CONDUCTOR SHALL BE LL _ (11 x 1.21)x 1.25 = 16.64 A INCREASED TO 6 AWG CU. SELECTED OCPD IS 20A GROUNDING NOTES: SELECTED EQUIPMENT GROUNDING CONDUCTOR(EGC)_#10 THWN-2 ...NEC 250.122(A) PV MODULE AND RACKING GROUNDING AS PER APPROVED INSTALLATION PRACTICE AND IN LINE WITH SIGNATURE WITH SEAL MANUFACTURE'S GUIDELINES. PERMIT DEVELOPER DATE 07/24/2021 DESIGNER OPS REVIEWER ELECTRICAL CALCULATIONS PV-4 EQUIPMENT ELEVATION VIEW ��%i LORD&LAWRENCE JW CONSULTING ENGINEERS CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA MAIN SERVICE PANEL AC DISCONNECT AC COMBINER PANEL FLORIDA REGISTRY#83317 UTILITY METER (INSIDE HOUSE) (FUSIBLE) (OUTSIDE HOUSE) (OUTSIDE HOUSE) (OUTSIDE HOUSE) •UrbanSolar CONTACT:561-609-2664 990 SOUTH ROGERS CIRCLE SUITE 4 BOCA RATON,FL 33487 SOLAR CONTRACTOR LICENSE:CVC56948 axorovoTuc SYSTEM /r 0 co , IY J C) L.L CD LEI Co Q W m a Lo CD x 0 c� SIGNATURE WITH SEAL SOLAR AC DISCONNECT AC COMBINER NOTICE NOTICE SHUTDOWNRAPID FOR SOLAR PV SYSTEM DO NOT ADD LOADS. SOLAR PV SYSTEM EQUIPPED SOLAR PV SYSTEM EQUIPPED WARNING UTILITY METER WITH RAPID SHUTDOWN WITH RAPID SHUTDOWN WARNING FIRST RESPONDERS: PERMIT DEVELOPER TURN RAPID SHUTDOWN THIS SOLAR PV SYSTEM SWITCH TO THE A4\ IS EQUIPPED WITH RAPT SOLAR ELECTRIC DATE 07/24/2021 "OFF" POSITION TO SHUTDOWN. TURN RAPID PV PANELS SHUTDOWN PV SYSTEM SHUTDOWN SWITCH TO AND REDUCE THE "OFF" POSITION TO JEMERGENCY CONTACTI DESIGNER OPS SHOCK HAZARD SHUT DOWN ENTIRE PV THE MATERIAL USED FOR THE PHOTOVOLTAIC SYSTEM REVIEWER IN ARRAY SYSTEM. 561-609-2664 LABELS SHALL BE REFLECTIVE,WEATHER RESISTANT, AND CONSTRUCTED OR DURABLE ADHESIVE MATERIAL LABELS OR ANOTHER APPROVED MATERIAL SUITABLE FOR THE ENVIRONMENT IN COMPLIANCE WITH NFPA 1-11.12. PV-5 0 P11/4 LORD&LAWRENCE CONSULTING ENGINEERS CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA FLORIDA REGISTRY#f 83317 JUNCTION BOX 27 1-7 18" SETBACK UrbanSolar 1 CONTACT:561-609-2664 990 SOUTH ROGERS CIRCLE SUITE 4 BOCA RATON,FL 33487 LEGENDS SOLAR CONTRACTOR LICENSE:CVC56948 0 00 ❑ -WIND ZONE 1 1 -1,1--I O O ; ❑ -WIND ZONE 1' rl (V N WIND ZONE 2 Lo ------ - ----- co ■ -WIND ZONE (2) O m CD ❑ -WIND ZONE (2r) LL "t L W ono El -WIND ZONE (2e) Q U (E)SERVICE DROP < Lu 28'-811 13' ❑ -WIND ZONE (2n) Q W Lo a m Lo WIND ZONE 3 O FNt Lq Q ~ 56'-3" ❑ -WIND ZONE (3) ~ 0 N -WIND ZONE (3r) SOLAR MODULE ■ -WIND ZONE (3e) SIGNATURE WITH SEAL WIND LOAD INFORMATION: THIS SYSTEM HAS BEEN TO MEET ROOF 1 THE REQUIREMENTS OF THE 7 HN EDITION OF THE FLORIDA BUILDING CODE AND USED THE FOLLOWING DESIGN PARAMETERS: ULTIMATE WIND SPEED: 160 MPH EXPOSURE CATEGORY: B RISK CATEGORY: II MEAN ROOF HEIGHT: 15 FT ROOF SLOPE: 7°-20° EQUIPMENT SPECIFICATIONS NOTES: LEGENDS ROOF SPECIFICATIONS ROOF INFORMATION 1. LOCATION OF JUNCTION BOX(ES), AC • PV ROOF ATTACHMENT Q EQUIPMENT DESCRIPTION QUANTITY ROOF UANTITY SLOPE AZIMUTH DISCONNECTS(S), AC COMBINER PANEL(S), AND - ROOF MATERIAL ASPHALT SHINGLE MODULE JKM405M-72HL-V G2(405W)JINKO SOLAR 11 ROOF 1 11 14.04°(3/12) 180° OTHER ELECTRICAL EQUIPMENT(S) RELEVANT TO - -RAILS PERMIT DEVELOPER ROOF CONDITION GOOD PV INSTALLATION SUBJECT TO CHANGE BASED ENPHASE IQ7PLUS-72-2-US INVERTER 11 ON SITE CONDITIONS. - MICROINVERTERS RAFTERS 2"X4"@24"O.C. -RAFTERS/TRUSSES DATE 07/24/2021 JUNCTION BOX SOLTECTION RJ-1 ROOFTOP 1 2. TRUSS LOCATIONS ARE APPROXIMATE. ACTUAL COMBINER PANEL 80AENPHASEIQCOMBINER3 LOCATIONS MAY DIFFER AND CONTRACTOR MAY O ❑ - ROOF OBSTRUCTION DESIGNER DIPS 1 NEED TO ADJUST MOUNT LOCATIONS. IN NO AC DISCONNECT AC DISCONNECT 240V,30 AMP,WITH 1 SYSTEM INFORMATION CASE SHALL THE MOUNT SPACING EXCEED "MAX. ❑ JUNCTION BOX REVIEWER 20A FUSES,NEMA 3R,UL LISTED ATTACHMENT DC SYSTEM SIZE 4.455KW MOUNT 3. PROPOSED LAYOUT IN ❑ QUICKMOUNT(L-MOUNT) 33 - FIRE SETBACK RACKING LAYOUT AC SYSTEM SIZE 3.19KW COMPLIANCE WITH NFPA 1,2018 EDITION RACKING SYSTEM IRONRIDGE(XR100)RAILS - PV-6 LORD&LAWRENCE CONSULTING ENGINEERS IRONRIDGE (XR100) RAIL IRONRIDGE (XR100) RAIL CONTACT:(561)444 8192 QUICK MOUNT(L-FOOT) // \ 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL33463,USA QUICK MOUNT(L-FOOT) FLORIDA REGISTRY�83317 SOLAR MODULE \ UrbanSOlar QUICK MOUNT, L-FOOT CONTACT:561-609-2664 — SHINGLE FLASHING / 990 SOUTH ROG RSCIRC ESUITE4 / BOCA RATON,FL 33487 SOLAR CONTRACTOR LICENSE:CVC56948 WOOD SHEATHING WOOD ROOF � QUICK MOUNT, L-FOOT TRUSS TYP. _ _ _ . SHINGLE FLASHING 5/16"x4" STAINLESS W 0 co WOOD ROOF STEEL LAG SCREW aco 0 M TRUSS TYP. L W co Q W LO a m LO LANDSCAPE PORTRAIT (0 o N x Span limits am ~ Span limits 0 sm SIGNATURE WITH SEAL XR10 XR160 XR7000 XR10 XR100 X111000 Zone 1 9 Normal 4'(1'7") 6'(2'5') 6'(Z 5') Zone 10 Normal 4'(1'7,1 6'(2'5") 6'(2'5") Exposed 3'6"(1'4") 5'4"(2'1°) 5'4"(Z'1"1 Exposed 3'9"(1'6"7 5'7"a'3') 5'T(2'3") Zone 2r Normal 3'10"(V 6") 5'10"(2'4") 5'10"(2'4') Zone 2r Normal 4'(1'7") 6'(2'S') 6'R'5-) Exposed v pl 4'4"(1'8") 4'4"(1'8") Exposed 2'10"(V 1'7 4'8'.(1.10") 4'8"(1'10') Zone 2e/3 Normal 3'7"(1'S") 5'6"(2'2") 5'6"(2'2") Zone 2e/3 Normal 4'(1,7..) 5'11"(2'S') 5'11'(2'5"1 Expcsed 0-(0-) 4'(1'7"I 4'(1'7"1 Exposed 0-co..) 4'5"(1'9') 4'5"(1'T) System Weight System Weight Total system weight 72.3 Ihs Total system weight 570.2 Ibs Weight/aLtachment 18:1 Ibs Weight/attachment 31.7 1bs PERMIT DEVELOPER Racking weight 22.71bs !tacking weight 74.1 Ibs DATE 07/24/2021 Distributed weight 3.3 pst Distributed weight 2.6 psf DESIGNER OPS I CERTIFY THAT THE EXISTING ROOF AND BUILDING REVIEWER STRUCTURE CAN WITHSTAND ALL DEAD LOADS IMPOSED BY THE PHOTOVOLTAIC SYSTEM AND ALL STRUUIT AL DETAILS STRUCTURAL DETAILS WIND LOADS OF SPECIFIED INTENSITY IN ACCORDANCE PV-7 WITH THE FLORIDA BUILDING CODE. _0911%LORD&LAWRENCE CONSULTING ENGINEERS 'ill I CONTACT:(561)444 8192 00 LAKE WORTH ROAD SUITE 211 ENGINEERING DRAWINGS MECHANICAL CHARACTERISTICS 57GREENACRES,FL33463,USA Front Side Back FLORIDA REGISTRY#83317 1002..131.15.1 x ss:mm ia.na-i Cells Mono PERC Diamond Cell.1158.75xl58.75mm) n No.of Halt Cells 14416.241 11111I Dimensions 2008.1002.40mm f79.06.39.45:1.57in) Weight 22.5kg 149.b1bs1 `•'::Front Glass 3.2mm,Anti-Reflection Coating =•Urban Sold.r High Transmission,Low Iron,Tempered Glass •`'•'` <� o Frame Anodized Aluminum Alloy IMM Wo ■ ■ ■ , \\��� ,,, IIIII I ° U Junction Box IP67 Rated u CONTACT:561-609-2664 InITI II I IILL ll - I - Output Cables 12 AWG,1400mm(55.12in)or Customized Length 990 SOUTH ROGER$CIRCLE SUITE 4 II f I Fire Type Type 1 BOCA RATON,FLNSE:C Pressure Rating 5400 Pa(Snow)&240OPa(Wind) SOLAR CONTRACTOR LICENSE: VC56948 ,bobI .TTf n EAGLE 72HM G2 �,���/ a' s Length:m2mm TEMPERATURE CHARACTERISTICS Width:t 2mm 390-410 WATT - HALF CELL MONO PERC MODULE Temperature 0.35%/°C Height:t 1mm p to � -- ` Positive power tolerance of 0- +3% Row Pitch:t2mm Temperature Coefficients of Voc 0.29%/°C W Q M Temperature Coefficients of Isc 0.048%/°C C� Nominal Operating Cell Temperature INOCTI 45t2°C ^ J O U LL ELECTRICAL PERFORMANCE&TEMPERATURE DEPENDENCE • NYSE-listed since 2010,Bloomberg Tier 1 manufacturer , O Current-Voltage&Power-Voltage Temperature Dependence LU 00 • Best-selling module globally for last 4 years „ Curves 141OWI of Isc,Voc,Pmax < U • Top performance in the strictest 3rd party Labs MAXIMUM RATINGS a:o , Operating Temperature I°C) -40°C-+85°C Q LU • 99.9%on-time delivery to the installer to o a COa LLQ 's 1f0 Maximum System Voltage 150OVDC(UL and IEC) se o< •0 °• Automated manufacturing utilizing artificial intelligence (~ Maximum Series Fuse Rating 20A ../ O to 0 x W • Vertically integrated,tight controls on quality ,00 of rQ O • Premium solar panel factories in USA and Malaysia / - x LL N 5 111 15 20 25 3D 25 4° 45 N PACKAGING CONFIGURATION Volta LINEAR PERFORMANCE WARRANTY KEY FEATURES [Two pallets=One stack) 25 25-Year Performance Warranty o 0 25 25 00 27pcs/pallet,54pcs/stack,594pcs/40'HO Container Diamond Half Cell Technology celLremperature(°cl World-record breaking efficient mono PERC half cut SIGNATURE WITH SEAL 9J.5% solar cells deliver high power in a small footprint. ELECTRICAL CHARACTERISTICS ,o% O Designed for Long Life Uses the same DuPont protective film as the Space Module Type JKM390M-72HL-V JKM395M-72HL-V JKM400M-72HL-V JKM405M-72HL-V JKM410M-72HL-V 60% Station,Mars Lander,and jetliners.25-year warranty. STC NOCT STC NOCT STC NOCT SCT NOCT SCT NOCT _ 20% Maximum Power 1391 287Wp 395Wp 29l Wp 40OWp 294Wp 405Wp 298Wp 411 302Wp 0% Shade Tolerant Maximum Power Voltage(Vmpl 39.64V 37.OV 39.90V 37.4V 40.16V 37.6V 40.42V 37.8V 40.68V 38.OV U , s ,o ,s :° Q Twin array design allows continued performance Maximum Power Current(Imp) 9.84A 7.75A 9.90A 7.77A 9.96A 7.82A 10.02A 7.88A 10.08A 7.94A Y°'s5 even with shading by trees or debris. _ Open-circuit Voltage lVoc) 48.6V 45.8V 48.8V 46.OV 49.1V 46.2V 49.4V 46.5V 49.6V 46.7V Power Boost in Cloudy Conditions Short-circuit Current Ilse) 10.46A 8.45A 10.54A 8.51A 10.61A 8.57A 10.69A 8.63A 10.76A 8.69A iKM•°om��zx�-v - A special film diffuses light,boosting performance Module Efficiency STC I%I 19.38% 19.63% 19.88% 20.13% 20.38% °s ® CE F�lt t IMM 0 LISTEDeven with shading by trees or debris. *STC: *,Irradiance 1000W/m2 (� Cell Temperature 25°C � AM=1.5 Protected Against All Environments 1.5 2 Ambient Temperature = Wind Speed 1 m/s NOCT:�;Irradiance 800W/m erature 20°C AIV p Certified to withstand humidity,heat,rain,marine • IS09001:2008 Quality Standards OHSAS18001Occupational 'Power measurement tolerance:t3% environments,wind,hailstorms,and packed snow. •IS014001:2004 Environmental Standards Health&Safety Standards •IEC61215,IEC61730 certified products UL1703 certified products PERMIT DEVELOPER . ,S,Orli2 The company reserves the final right for explanation on any of the information presented hereby.JKM390-410M-72HL-V-A4-US .BUILDING YOUR TRUST IN SOLAR.JINKOSOLAR.US •J/nK0 BUILDING YOUR TRUST IN SOLAR.JINKOSOLAR.US ._hnKO DATE 07/24/2021 DESIGNER OPS REVIEWER MODULE DATASHEET PV-8 LORD&LAWRENCE CONSULTING ENGINEERS CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA Data Sheet Enphase IQ 7 and IQ 7+ Microinverters FLORIDA REGISTRY#83317 Enphase Microinverters Region:AMERICAS INPUT DATA(DC) IQ7-60-2-US IQ7PLUS-72-2-US Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48 V 60 V UrbanSa[ac Peak power tracking voltage 27 V-37 V 27 V-45 V Operating range 16 V-48 V 16 V-60 V Min/Max start voltage 22 V/48 V 22 V/60 V Max DC short circuit current(module Isc) 15 A 15 A CONTACT:561-609-2664 Enphase The high-powered smart grid-ready Overvoltage class DC port II II 990 SOUTH ROGERS CIRCLE SUITE 4 DC port backfeed current 0 A 0 A BOCA RATON,FL 33487 Enphase IQ 7 Micro"and Enphase IQ 7+ Micro'" SOLAR CONTRACTOR LICENSE:CVC56948 PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; Q 7 a n d IQ 7+ dramatically simplify the installation process while AC side protection requires max 20A per branch circuit achieving the highest system efficiency. OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Microinverters Peak output power 250 VA 295 VA Part of the Enphase IQ System,the IQ 7 and Maximum continuous output power 240 VA 290 VA IQ 7+Microinverters integrate with the Enphase Nominal(L-L)voltage/range2 240 V/ 208 V/ 240 V/ 208 V/ 9 P 211-264 V 183-229 V 211-264 V 183-229 V IQ Envoy'',Enphase IQ Battery-,and the Enphase Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) 0 rn Enlighten'"monitoring and analysis software. Nominal frequency 60 60 W Q M Extended frequency range 47-6 68 Hz 47- 8 Hz � Q IQ Series Microinverters extend the reliability AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms U J It Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) LL standards set forth by previous generations and Overvoltage class AC port III III � LU 00 undergo over a million hours of power-on testing, AC port backfeed current 18 mA 18 mA Q U enabling Enphase to provide an industry-leading Power factor setting 1.0 1.0 Q W Power factor(adjustable) 0.85leading...0.85lagging 0.85leading...0.85 lagging Q m _ L0 warranty of up t0 25 years. EFFICIENCY @240 V @208 V @240 V @208 V a a Lo Peak efficiency 97.6% 97.6% 97.5% 97.3% O CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% Cfl MECHANICAL DATA ~ LL CV Ambient temperature range -40°C to+65*C Relative humidity range 4%to 100%(condensing) Easy to Install Connectortype MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) c Dimensions(HxWxD) 212 mm x 175 mm x 30.2 mm(without bracket) Lightweight and simple Weight 1.08 kg(2.38 Ibs) Faster installation with improved,lighter two-wire cabling Cooling Natural convection-No fans SIGNATURE WITH SEAL Built-in rapid shutdown compliant(NEC 2014&2017) Approved for wet locations Yes Pollution degree PD3 Productive and Reliable Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor Optimized for high powered 60-cell and 72-cell*modules FEATURES More than a million hours of testing Communication Power Line Communication(PLC) Class II double-insulated enclosure Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. UL listed Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break _ disconnect required by NEC 690. Smart Grid Read Compliance CA Rule 21(UL 1741-SA) y UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Complies with advanced grid support,voltage and This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and frequency ride-through requirements NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC Remotely updates to respond to changing and DC conductors,when installed according manufacturer's instructions. grid requirements Configurable for varying grid profiles Meets CA Rule 21(UL 1741-SA) PERMIT DEVELOPER *The IQ 7+Micro is required to support 72-cell modules. DATE 07/24/2021 ® 1.No enforced ageDC/AC range ratio.See the compatibility calculator at quire//y the n-us/suonort/module-com atibility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. DESIGNER OPS E N P H A S E To learn more about Enphase offerings,visit enphase.com E N P H A S E REVIEWER To learn more about Enphase offerings,visit enphase.com `� ©2020 Enphase Energy.All rights reserved.Enphase,the Enphase logo,Enphase IQ 7,Enphase IQ 7+,Enphase IQ Battery, Enphase Enlighten,Enphase IQ Envoy,and other trademarks or service names are the trademarks of Enphase Energy,Inc.Data subject to change.2020-01-06 INVERTER DATASHEET PV-9 LORD&LAWRENCE W CONSULTING ENGINEERS SO litecti o n TM SO ltf�let'o n TM CONTACT:(561)4448192 5700 LAKE WORTH ROAD SUITE 211 by vynckier GREENACRES,FL33463,USA I,y vVnlckier FLORIDA REGISTRY#83317 RJ-1 Features & Benefits =•UrbanSo[ar Residential Transition Box Soltection's new RJ-1 is ajunction box with integrated flashing to be used on residential solar installs with CONTACT:561-609-2664 The SoltectionRJ-1 rooftop junction box with flashing 990 SOUTH ROGERS CIRCLE SUITE 4 composite shingle roofing. BOCA RATON,FL 33487 provides a safe,secure,and NEMA 4X watertight SOLAR CONTRACTOR LICENSE:CVC56948 solution for the Solar installer to penetrate the roof for attic runs and make the proper wire connections. The product is designed to be simple to install, minimize time on the roof,while additionally providing higher levels of protection for the point of Q ' j Ground bar included Fewer mounting holes 0 M penetration in the roof as well as electrical in standard offering equal better seal U LL "4: connections inside the junction box. j 0 LLI 00 Q LLI m — LO Key Features Specifications a - Cp IY � • Designed specifically for solar installations Enclosure 0 N • Light weight • Non-metallic---Will NOT rust/corrode Material:Polycarb blend w/UV inhibitors Captive screws in p NEMA 4X—poured uv stabilized:Yes • Ealsy to drill/modify Impact Resistance:Yes cover will not fall out in place gasket • Captive screws in cover-will not fall out Weight:2.731b SIGNATURE WITH SEAL • Minimal design,small footprint Color:Graphite Black • NEMA 4X rated • All roof penetrations cover Key Features by Nema 4x enclosure Dimensions Flashing Dimensions(Approximate):13"x 18" • Cost effective Enclosure Dimensions(Approximate):8"x 8" • Light weight(2.73 lbs) Total Product Height:3.5" • Dark Graphite color-blends in with any rooftop Cubic Inches:224 Cubic Inches • Non-metallic:will not rust/corrode C UL us • Easy to drill/modify LISTED • Designed specificallly with solar installer in mind • Minimal design,small footprint PERMIT DEVELOPER Soltection by Vynckier Soltection by Vynckier Vynckier Enclosure Systems n �1 �� Vynckier Enclosure Systems DATE 4 ` 07/24/2021 271 McCarty Street,Houston,TX 77029 USA 271 McCarty Street,Houston,TX 77029 USA +1.866.227.0577 L e +1.866.227.0577 www.soltection.com LISTED www.soltection.com DESIGNER OPS REVIEWER JUNCTION 13OX DATASHEET PV-10 LORD&LAWRENCE Data Sheet Enphase IQ Combiner 3 Enphase Networking "` CONSULTING ENGINEER MODEL NUMBER IQ Combiner 3 IQ Combiner 3 with Enphase IQ Envoy'printed circuit board for integrated revenue grade PV CONTACT:(561)444 8192 X-IQ-AM1-240-3 production metering(ANSI C12.20+/-0.5 i)and optional*consumption monitoring(+/-2.5i). 5700 LAKE WORTH ROAD SUITE 211 ACCESSORIES and REPLACEMENT PARTS(not included,order separately) GREENACRES,FL 33463,USA Enphase Mobile Connect'" FLORIDA REGISTRY#83317 CELLMODEM-03(413/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 CELLMODEM-01(3G/5-year data plan) microinverters.(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, CELLMODEM-M1(4G based LTE-M/5-year data plan) where there is adequate cellular service in the installation area.) Consumption Monitoring*CT Split core current transformers enable whole home consumption metering(+/-2.5i). Enphase The Enphase IQ Combiner 3'"with Enphase CT-200-SPLIT 11p{.+� 1E p *Consumption monitoring is required for Enphase Storage Systems •: :•y1 banSolar.. IQ Envoy`"" consolidates interconnection Wireless USB adapter Installed at the IQ Envoy.For communications with Enphase Encharge'"storage and Enphase Q Combiner 3 COMMS-KIT-01 Enpower'"smart switch.Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner' equipment into a single enclosure and and allows redundant wireless communication with Encharge and Enpower. Circuit Breakers Supports Eaton BR210,BR215,BR220,BR230,BR240,BR250,and BR260 circuit breakers. CONTACT:561-609-2664 (X-IQ-AM1-240-3) streamlines PV and storage installations by BRK-10A-2-240 Circuit breaker,2 pole,1 OA,Eaton BR21 0 990 SOUTH ROGERS CIRCLE SUITE 4 BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 BOCA RATON,FL 33487 providing a consistent, pre-wired solution for BRK-20A-2P-240 Circuit breaker,2 pole,20A,Eaton BR220 SOLAR CONTRACTOR LICENSE:CVC56948 EPLC-01 Power line carrier(communication bridge pair),quantity-one pair residential applications. It offers up to four XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) 2-pole input circuits and Eaton BR series XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 ELECTRICAL SPECIFICATIONS busbar assembly. Rating Continuous duty System voltage 120/240 VAC,60 Hz LO � Eaton BR series busbar rating 125 A �W- Q q M C7 Max.continuous current rating(output to grid) 65 A O Y J O Max.fuse/circuit rating(output) 90 A U Q LL O Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) '� 0� LLI Op Smart Max.continuous current rating(input from PV) 64 A (]a Q U Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included r Includes IQ Envoy for communication CO W LO and control Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy a CO U0 Flexible networking supports Wi-Fi, MECHANICAL DATA T T CD Lf) Ethernet,or cellular Dimensions(WxHxD) 49.5 x 37.5 x 16.8 cm(19.5"x 14.75"x 6.63").Height is 21.06"(53.5 cm with mounting brackets). l Optional AC receptacle available for PLC Weight 7.5 kg(16.5 Ibs) x, LL N bridge I Ambient temperature range -40°C to+46°C(-400 to 115°F) Provides production metering and optional Cooling Natural convection,plus heat shield consumption monitoring Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction Wire sizes 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors * Simple 60 A breaker branch input: 4 to 1/0 AWG copper conductors SIGNATURE WITH SEAL / Main lug combined output: 10 to 2/0 AWG copper conductors F Reduced size from previous combiner Neutral and ground: 14to 1/0 copper conductors Always follow local code requirements for conductor sizing. " Centered mounting brackets support single Altitude To 2000 meters(6,560 feet) stud mounting w«t ! ➢- • Supports back and side conduit entry INTERNET CONNECTION OPTIONS -- Up to four 2-pole branch circuits for 240 VAC Integrated Wi-Fi 802.11b/g/n y plug-in breakers(not included) Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) 80 A total PV or storage branch circuits Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G)or CELLMODEM-M1(413 based LTE-M) (not included) COMPLIANCE Reliable Compliance,Combiner UL 1741, CAN/CSA C22.2 No.107.1,47 CFR,Part 15,Class B,ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 3R enclosure U� Five-year limited warranty UL listed To learn more about Enphase offerings,visit enohase.com LISTED ©2018 Enphase Energy.All rights reserved.Enphase,the Enphase logo,IQ Combiner 3,and other trademarks or service names are the PERMIT DEVELOPER E N P H A S E trademarks of Enphase Energy,Inc. EN PHASE To learn more about Enphase offerings,visit enohase.c:om `/ 2019-11-04 DATE 07/24/2021 DESIGNER OPS REVIEWER COMBINER PANEL DATASHEET PV-11 LORD&LAWRENCE CONSULTING ENGINEERS CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 AAEL. IRONRIDGE TECHBULLETIN Z'Awl IRONRIDGE TECHBULLETINGREENACRES,FL33463,USA FLORIDA REGISTRY#83317 FLORIDA PRODUCT APPROVAL Pressure Tables •UrbanSo[ar. The following tables were prepared by IronRidge to provide a quick reference for the maximum wind uplift pressures on gable and hip roofs at different tilt angles(see full Florida Approval Pressure Tables document on the IronRidge website for official stamped version). im • • • Gable Roofs • CONTACT:561-609-2664 Roof 990 SOUTH ROGERS CIRCLE SUITE 4 BOCA RATON,FL 33487 Tilt Exposure • SOLAR CONTRACTOR LICENSE:CVC56948 Angle The First in Florida Ir Group I Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2 Group 8-20° 1 35 47 55 48 63 74 57 75 89 In 2020, IronRidge became the first High Velocity Hurricane Zone(HVHZ) �\\,]][]] /// 21-27° 27 39 44 37 53 59 44 63 71 approved solar system in accordance with 7-10 building code.We are happy to \�\� �G �•�,V/S/p j/ 28-45° 27 32 40 36 43 54 43 52 64 share that the Flush Mount System is now HVHZ-approved in accordance with �� �,T APp''•.• �i 7-16 as well.We are committed to safe solar,even in extreme environments. \* ;•Op 90G: *i Roof •• Maximum Wind Uplift Pressure for Hip -••fs � co Q FL#29843 y°: W Q -:3- co The rigorous evaluation process for Florida Product Approval includes testing for = :4 t' : _ Tilt Exposure■ ~ CO resistance to high wind forces(TAS 202)and wind-driven rain[TAS 100(A)],and = _ * W _ Group I Group 2 Group 3 Group 1 Group 2 Group 3 Group 1 Group 2J Group 3 U [Y J 0 LL ongoing auditing of quality assurance programs. _ `OZ 1 0 L:• STATE OF N 8-20° 33 39 42 44 53 57 52 63 68 LLj OO Our Florida Product Approval(FL#29843)covers all Flush Mount components �i,/c<`�O.• F�ORf�p ��\��� 21-27° 22 32 32 30 43 a3 35 52 52 pa and applies to all regions of the state of Florida both inside and outside the high C, P velocity hurricane zones(HVHZ),up to 100 PSF of wind pressure.The approval /fir "Ty HUR?R\ \�\� 2a 45° 2a 2s 3a 32 3s as 3s a1 55 m W to also lists allowable rail spans for configurations using either XR10,XR100,or /// 0 Footnotes: to XR1000 mounting rails as well as multiple IronRidge roof attachments. IT 1.The pressure forces tabulated are per ASD(Allowable Stress Design)method and Florida Building Code 2020. 2.The pressure values are calculated based on the single module area of 22 sf as the maximum allowed and 25 It building height defined as the O N average of the roof ridge and even height. x LL 3.The tabulated values are based on the selected ultimate design wind speed Vult of 175 mph.For other chosen ultimate wind speed(Vult-other), the pressure shall be adjusted per the following equation:Pressure forVult-other-=Pressure from the table x(Vult-other l75) Approved Components 4.The pressures are calculated for non-exposed modules in the array as defined by ASCE 7-16 Section 29.4.4.For exposed modules,the pressure shall be multiplied by an edge factor of 1.5. 5.The table is applicable to an array which maintains a minumum edge distance(to ridge,Save,side rake,or hip)of 2xh2(h2 is the clearance from the roof surface to underside of the module),and contains modules with the maximum dimension not exceed 80.4". _ SIGNATURE WITH SEAL Groj • • • •• • • - 101 IT UFO+Stopper CAMO RoofI 21-27' Universal Mid- Hidden End Cam for Slope Slope and End-Clamp Superior Aesthetics L97—Jr Rar:ers ACE 1 2n 3r 1 2n 3e ASCE 1 2r 2e 1 2e 3 1 2e 2r 7_16 2e 2r 2e 3r 7-16 3r 2r 3 Roof 3e 2r Roof 2-Rall 3-Rail 1 Zones Zones Standard Rack Extra Support for XR10 Rail XR100 Rail XR1000 Rail Low-Profile Rail for Ultimate Residential Rail Paired with XR100 for ,a Configuration Module Frames Spans up to 48" for Spans up to 72" 3-Rail Configurations �[� [F"�[� �a Notation(Per ASIDE 7-15) a 10%of least horizontal dimension or 0.4h,whichever is smaller,but not less than • 3 either 4/of least horizontal dimension or 3 ft(0.9 m).If an overhang exists,the edge distance shall be measured from the outside edge of the overhang.The hotiontal ! dimensions used to compute the edge distance shall not O OO O;® include any overhang distances. wind of bwid g measured normal to B Horizontal rizontl dimensionu PERM DEVELOPER Flashvue FlashFoot2 KnockoutTile L-Foot+Seam Clam L-Foot+Anchor %"o in m IT DE p y y h=Mean roof height,in ft m h Composition Shingle Composition Shingle Flat,S-,and W-Tile ®j-®--;-, -®- ® 1— 3 ------------ - g ( )• I g l DATE 07/24/2021 Roof Attachment Roof Attachment Roof Attachment Multiple Metal Roof Multiple Direct `}� 0=Angle of lane of roof from horizontal,in degrees. r ELEv Attachment Options Anchoring Options Cable Roof Zones n Hip Roof Zones 9 P 9 �•t� DESIGNER OPS REVIEWER RACKING DATASHEET PV-12 LORD&LAWRENCE i%W CONSULTING ENGINEERS CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA FLORIDA REGISTRY#83317 '�•UrhanSolar, L-Mount Installation Instructions Reference and Tips L—Mount Q M IL M / QMLM— 1CT Installation Tools Required:tape measure,roofing bar,chalk line,stud finder,caulking gun,sealant compatible with roofing materials,drill with 7/32"or 1/8"bit,drill or impact gun with 1/2"socket. CONTACT:561-609-2664 Elevated Water Seal Technology® 990 SOUTH ROGERS CIRCLE SUITE 4 ■ • , , ■ ,- BOCA RATON,FL 33487 Proper Flashing Placement SOLAR CONTRACTOR LICENSE:CVC56948 ITEM DESCRIPTION QTY. II THIS EDGE TOWARDS ROOF RIDGE N FLASHING,ROUNDED CORNERS,9"X 17'X.040',.43fT'HOLE,5052 1 �" 2 T6 6005A-T61 MILL L-FOOT, FASTENER,2-1/I6"SLOT.6061- MILL 1 —- 3 WASHER.SEALING,5/16"ID X 3/4"OD,EPDM BONDED SS 1 IJT 4 LAG SCREW,HEX HEAD.5/1e xr.188 SS I ,5 STRUCTURAL SCREW,QMPV,T 0HES WASHER HEAD,5/I6"X4-1/7, 1 ❑ - ❑ LO �g r 12.00 JRUCTURAL OC� 4 Locate,choose,and mark centers of rafters to be Carefully lift composition roofshingle with roofing Insert flashing between 1st and 2nd course.Slide 0CL mounted.Select the courses of shingles where bar,just above placement of mount.Remove up so top edge of flashing is at least N"higher ^(4.20 mounts will be placed. nails as required and backfill holes with aproved than the butt-edge of the 3rd course and lower iJ (] 3.00 3 SCREW sealant.See"Proper Flashing Placement"on next flashing edge is above the butt-edge of lst course. ® 0nNL,I/� AVAILABLE ON page. Mark center for drilling. Q w Op QMLM-ST \..J 4.50 VERSIONS ONLY 9.00 2 Q UJ m F� m LO 2.00 0.408 ® Additional tips and information for installing mounts: O H Lf) T 2.09 O (fl ■ See Quick Tips videos on nail removal,and more at: ti 0 3.30 .90) 1 AVAILABLE IN MILL, ,l.. 11��--II CV AND BLACK FINISHES # http://www.quickmountpv.com/Support/videos.htmi I-4 LL Quick Mount Pv, ■ It is not necessary or advisable to use nails or other fasteners to secure the perimeter of 040 —� TILE, the flashing. (3.54) 7— 4.04 QMLM$r QMLM-ST:L-MOUNT,Z- If attaching with lag bolt uses b,"bit(Lag).Use Clean off any sawdust,and fill hole with sea lant Place L-foot onto elevated flute and rotMe L-foot to 2.75 'h"bit(ST)for attaching with the structural screw compatible with roofing materials. desired orientation. 1 1/16"SLOT Drill pilot hole into roof and rafter,taking care to ■ The L-Mount is made to work with standard and high-definition composition/asphalt and wood shingle QMLM QMLM-ST SRE IXfAWNBY: AAP REv drill square to the roof.Do not use mount as a drill roofs with 5"to 5-5/8"co u rses.Ifthe exposed surfaceof the course exceeds thismeasu rem entyoumay guide.Drill a 2"deep hole into rafter. A imm: v4—ismv 11 need to use our Classic Shake Mount instead. SIGNATURE WITH SEAL _A_O_ —1°` ■ Depending on the season and climate,size and location of seal tabs,and quality of the shingles,the sn 4 w 3 z ' seal tabs that adhere the shingle courses together may not effectively seal the shingles to the flashings. written instructions must also b If this is the case,simply add several quarter-sized dabs of manufacturer accepted sealant or asphalt followed by anyone modifying roofing cement,meeting ASTM D 4586 Type II,between the flashing and the shingle above. a roof system.Consult the ■ Mounts should not be installed in areas of the roof susceptible to ice damming.Water ponding under roof manufacturer's specs and the shingles can reach the bolt penetration. instructions prior to working on the roof. ■ Take care not to damage the roofing material while working on the roof.Removing stone granules and deforming the shingles in any way can shorten the lifespan ofthe roofing.The value of the solar array is directly affected by the condition of the roof it is attached to. Prepare lag bolt or structural screw with sealing You are now ready for the rack of your choice. ■ CAUTION:Prior to installation,checkthat roper screw embedmentwill be achieved for the necessary site u i c k Mount PV` Washer.Using a'h-inch socket on an impact gun, Follow all the directions of the rack manufacturer P P y drive prepared lag bolt through L-foot until 1.400t as well as the module manufacturer.NOTE:Make load and roofing configurations. RESPECT THE ROOF can no longer easily rotate.DO NOT over-torque. sure top of L-Foot makes solid contact with racking. NOTE:Structural screw can be driven with T-30 hex head bit. BI 7.2.3-44 Apr-2019 Rev6 817.2.3-44 Apr-2019 Rev 6 BI 7.2.3-44 Apr-2019 Rev 6 PERMIT DEVELOPER DATE 07/24/2021 DESIGNER OPS REVIEWER ATTACHMENT DATASHEE'C PV-13 LORD&LAWRENCE CONSULTING ENGINEERS CONTACT:(561)444 8192 5700 LAKE WORTH ROAD SUITE 211 GREENACRES,FL 33463,USA FLORIDA REGISTRY#83317 Bostik MIAMI•DADE, MIAMI-DADE COUNTYsmart adhesives om .�•Urban�Q�2C — PRODUCT CONTROL SECTION 11805 SW 26 Street,Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)31525-99 CONTACT:561-609-2 664 NOTICE OF ACCEPTANCE(NOA) www.miamidade.eov/economy 990 SOUTH ROGERS CIRCLE SUITE 4 Bostik,Inc. BOCA RATON,FL 33487 9145 SOLAR CONTRACTOR LICENSE:CVC56948 11320 W.Watertown Plank Road POLYURETHANE SEALANT&ADHESIVE Wauwatosa,WI 53226-3413 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The documentation submitted has been reviewed and accepted by Miami-Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). -Tenacious bond to difficult substrates This NOA shall not be valid after the expiration date stated below.The Miami-Dade County Product M -Permanently flexible , 4 Control Section(In Miami Dade County)and/or the AHJ(in areas other than Miami Dade County) IY J CD -Miami-Dade approval NOA 17-0329.18, L.L 'Itreserve the right to have this product or material tested for quality assurance purposes.If this product 15-0520.01 or material fails to perform in the accepted manner,the manufacturer will incur the expense of such LU Opp testing and the AHJ may immediately revoke,modify,or suspend the use of such product or material Q () ' DESCRIPTION within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by 915 sealant is aone-component,smooth polyurethane adhesive Miami-Dade County Product Control Section that this product or material fails to meet the Q LU gis 915 capable of dynamic joint movement totaling 70%of original joint requirements of the applicable building code. �—) m LLo geometry(±35%).The sealant cures to a tough,flexible rubber H `t when exposed to moisture present in the atmosphere. This product is approved as described herein,and has been designed to comply with the Florida Building O L77 Code includingthe High Velocity Hurricane Zone of the Florida Building Code. c9 O N Bostik 915 all seasons formula has physical properties that C g ty g M will remain relatively stable over time.The cured performance w LL temperature range is-400F to 1500F.Where textured appearance DESCRIPTION:Bostik 915/915RT Sealant is needed,please use Bostik 916. a LABELING:Each unit shall bear a permanent label with the manufacturer's name or logo,city,state and APPLICABLE STANDARDS following statement:"Miami-Dade County Product Control Approved",unless otherwise noted herein. ASTM C920,TYPE S,GRADE NS,CLASS 35 USE NT,AAND M US Federal specification TT-S 00230C(COMB-NBS)for RENEWAL of this NOA shall be considered after a renewal application has been filed and there has one-component sealants as Class A,non-sag been no change in the applicable building code negatively affecting the performance of this product. SIGNATURE WITH SEAL CARB,SCAQMD,and OTC compliant Canadian Specification CAN/CGSB19.13-M87 typically days,prior to any mechanical stress testing procedures. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or Miami-Dade County,Florida,NOA No.:13.0423.10,05/24/17 It is recommended that adhesion testing be performed to capture change in the materials,use,and/or manufacture of the product or process.Misuse of this NOA as an batch control qualities of proposed substrates. • Miami-Dade -Static Uplift Resistance endorsement of any product,for sales,advertising or any other purposes shall automatically terminate this Joint Design: In general, more joint movement can be • AAMA808.3 NOA.Failure to comply with.any section of this NOA shall be cause for termination and removal of AAMA100/200/300 installation requirements accommodated in a thin bead of sealant than a thick bead.Bostik NOA. 915 should be no thicker than 1/2"(12.7mm)and no thinner than BASIC USES 114'(6.4mm).In joints between 1/2"and T',the ratio of sealant ADVERTISEMENT: The ]VOA number preceded by the words Miami-Dade County, Florida, and 915 is designed for applications from foundation to finish and width to depth should be approximately 2:1.Sealant depth injoints between 1/4"and 1/2"should be 1/4"deep..Joints with dynamic followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is is ideal for,sealing expansion and control joints,tilt up joints, p• y perimeters of doors,windows,and other wall penetrations.It movement should not be designed in widths lessthan1/4". displayed,then it shall be done in its entirety. has tenacious sealing and bonding performance for many roofing Surface Preparation:Surfaces must be structurally clean,dry(no INSPECTION:A copy of this entire NOA shall be provided to the user by the manufacturer or its applications,metal roofs,gutters,roof the installations,flashing frost)and structurally sound,free of contaminants,including,but and sheet metal applications. not limited to,dust,dirt,loose particles,tar,asphalt,rust,milt oil, distributors and shall be available for inspection at the job site at the request of the Building Official. 915 cures to form a durable,flexible bond with most building etc.If substrate is painted or coated,scrape away all loose and This NOA renews NOA No.13-0423.10 and consists of pages 1 through 3. materials such as stone,foam,masonry,ceramic,wood,steel, weakly bonded paint or coating.Any paint or coating that cannot The submitted documentation was reviewed by Jorge L.Acebo. Kynar"coated metals and copper and most other metals. be removed must be tested to verify adhesion of the sealant or to determine the appropriate surface preparation if needed.(See ASP I / INSTALLATION PROTOCOL section on next page for details.) IrVJ�/ Miami-Dade County Considerations:Mateorjoinadjacentsurfaces Backer Rods and Bond Breaker Tapes:Bond breakers including, priortothe Bostik 915 skinning and subsequent curing,to maximize but not limited to,closed-cell polyethylene backer rods are used wetting potential of the sealant to the substrates.Allow full-cure, tocontroldepth ofthe sealant bead,provide a firm tooling surface NOA No.:17-0329.18 PERMIT DEVELOPER MIAMI•DADE COUNTY Expiration Date: 05/24/22 • r This supersedesand repWces in its entiretyallpreviouslypubtishedversionsofthisdocum Approval Date: 05/04/17ent. DATE 07/24/2021 T1470(Last revised on 03.19.19) Page I.of 3 DESIGNER OPS REVIEWER SEALANT DATASHEET PV-14 LORD&LAWRENCE iW CONSULTING ENGINEERS CONTACT:(561)444 8192 /lr IRONRIDGE UFO Family of Components System Dia ram 5700 LAKE WORTH ROAD SUITE 211 y g GREENACRES,FL 33463,USA FLORIDA REGISTRY#83317 Simplified Grounding for Every Application - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _ - - -m- - - The UFO family of components eliminates the need for r an Q ar separate grounding hardware by bonding solar modules ■ directly to IronRidge XR Rails.All system types that feature 09-2664 the UFO family—Flush Mount,Tilt Mount and Ground \ CONTACT: ERS CIRCLES 1 990 SOUTH ROGERS CIRCLE SUITE 4 Mount—are fully listed to the UL 2703 standard. BOCA RATON,FL 33487 .- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SOLAR CONTRACTOR LICENSE:CVC56948 UFO hardware forms secure electrical bonds with both the module and the rail, resulting in many parallel grounding -� paths throughout the system.This leads to safer and more reliable installations. - - - - - - - - - - - - - - - - - - -m- - - - - - - - - - - - - - - - - - - w Q LID co co 000r- O� J O Stopper Sleeve Universal Fastening Object(UFO) The Stopper Sleeve snaps The UFO securely bonds solar modules to XIR LLJ OC) onto the UFO,converting it into Rails.It comes assembled and lubricated,and _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ U � - - - - - - - - a bonded end clamp. can fit a wide range of module heights. m- - - - - - - - - LID 1.4 m c- Lt7 d O N O UFO Stopper Sleeve • Grounding Lug m Bonded Splice Ground Wire x LL Q Approved Enphase microinverters can provide equipment grounding of IronRidge systems,eliminating the need for grounding lugs and field installed equipment ground conductors(EGC).A minimum of two microinverters mounted to the SIGNATURE WITH SEAL same rail and connected to the same Engage cable is required.Refer to installation manuals for additional details. / UL Certification Cross-System Corril 1[ �s �f \ The IronRidge Flush Mount, Feature Flush Mount I Tilt 1 0 0 0 V • \, Tilt Mount, and Ground Mount � XR Rails XR1000 Only Bonded Splice Systems have been listed to UL Each Bonded Splice uses �\ / \ 2703 by Intertek Group plc. UFO/Stopper d self-drilling screws to form a secure connection.No Bonded Splice N/A bonding strap needed. • UL 2703 is the standard for — / evaluating solar mounting Grounding Lugs 1 per Row 1 per Row 1 per Array i / systems. It ensures these devices Microinverters Enphase-M250-72, M250-60, M215-60,C250-72 will maintain strong electrical and &Power Darfon-MIG240, MIG300,G320,G640 Grounding Lug mechanical connections over O timizers SolarEd e-P300,P320,P400,P405,P600,P700, P730 A single Grounding Lug Bonded Attachments p 9 an extended period of time in _ connects anul entire row The bonding bolt attaches Fire Rating Class A Class A N/A of PV modules to the and bonds the L-foot to the extreme outdoor environments. 9 PERMIT DEVELOPER grounding conductor. rail.It is installed with the Tested or Evaluated with over 400 Framed Modules same socket as the rest of the O Go to IronRidge.com/UFO Modules Refer to installation manuals for a detailed list. DATE 07/24/2021 system. DESIGNER OPS ®� REVIEWER o � GROUNDING&BONDING DATASHEET PV-15