HomeMy WebLinkAboutEngineering Architectonic. Inc
April 4,2017
RECEWED APR 0
Saint Lucie County BuildingI Department
Attn:Roof Permit Plat!Review.,
2300 Virginia Avenue
FILE COPY.
Ft. Pierce, FL 34982
96: Roofing specification prepared for the St. Lucie County Building Dept.for the structure
located at 756 E. Prima Vista Blvd., Port St. Lticie, Florida
Manufacturer; Tri-Built Roofing Products
Profiles?, Tri—guilt Modified,FL#16027.91
Code.: FBC 2014;Section R 905.10
Wind Speed.-* 160 MPH;Ultimate Design Wind nd Sneeds,
Exposure: B
Mean Roof Height: 30'.M.aximurn
Pitch:: %/121
Required Design Pressure: Z6nel:-42.1 Zone 2.--50.0 Z6ne3A2.9
Maximum Uplift Pressure: -60 Zone.1&.Zone 2,-96.9 Zone 3.
Roof Decking:, Min 19/32"plywood at max,24"spans attached 67 o.c.,8cl x2"r.1ng
shank nails,
Saw 32 gi. 1-5/8 Inch diameter tin caps with 11 ga. annular ring shank nails.
Zone 1&Zone 2,8-inch o.c. in 4-inch lap.and 8-inch o.c. in.three,
equally spOced,staggered center rows. Zone 3,4-ihch o.c. in 4-inch lap
and 44rich o.c. in three,equally spaced,staggered center rows;
Ply Sheet (Optional)One or more SBS-SA or A' PP-TA
Cap: SBS-SA,APP-SA $RS-TA.ORAP.P-TA
The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code'r
and the Manufacturer's.recommendations..
0
Roe pktfblly Submitt6cl
AR089 8 is
A•Atteq-qnicInc.:
806 Delaware Avenue, Tel: 772 460 7151. wwW.architectonicintcom