HomeMy WebLinkAboutEngineering Architectonic. Inc April 4,2017 RECEWED APR 0 Saint Lucie County BuildingI Department Attn:Roof Permit Plat!Review., 2300 Virginia Avenue FILE COPY. Ft. Pierce, FL 34982 96: Roofing specification prepared for the St. Lucie County Building Dept.for the structure located at 756 E. Prima Vista Blvd., Port St. Lticie, Florida Manufacturer; Tri-Built Roofing Products Profiles?, Tri—guilt Modified,FL#16027.91 Code.: FBC 2014;Section R 905.10 Wind Speed.-* 160 MPH;Ultimate Design Wind nd Sneeds, Exposure: B Mean Roof Height: 30'.M.aximurn Pitch:: %/121 Required Design Pressure: Z6nel:-42.1 Zone 2.--50.0 Z6ne3A2.9 Maximum Uplift Pressure: -60 Zone.1&.Zone 2,-96.9 Zone 3. Roof Decking:, Min 19/32"plywood at max,24"spans attached 67 o.c.,8cl x2"r.1ng shank nails, Saw 32 gi. 1-5/8 Inch diameter tin caps with 11 ga. annular ring shank nails. Zone 1&Zone 2,8-inch o.c. in 4-inch lap.and 8-inch o.c. in.three, equally spOced,staggered center rows. Zone 3,4-ihch o.c. in 4-inch lap and 44rich o.c. in three,equally spaced,staggered center rows; Ply Sheet (Optional)One or more SBS-SA or A' PP-TA Cap: SBS-SA,APP-SA $RS-TA.ORAP.P-TA The above approved,as per Florida Building Code Compliance acceptances, 2014 Florida Building Code'r and the Manufacturer's.recommendations.. 0 Roe pktfblly Submitt6cl AR089 8 is A•Atteq-qnicInc.: 806 Delaware Avenue, Tel: 772 460 7151. wwW.architectonicintcom