HomeMy WebLinkAboutProduct Approval Florida Building Code Online Page 1 of 2
R E C E I V D APR 7 ;7
1 1!
�r 3 'ti'
l
dba
BCLS d3sna dog In Osea Re HXATc� S+3�t:Cuar4e Stm &Fans G�W�t� ��rz FEC Staff b Bt75 59e,I Ln;G q Sea+de
IF A .�,j Product Approval �' r
�L USER:Public User CO
PY
e iii"'®®®
.-- Prcf..rct Arnsrr�!F,r—>Prur:art¢-Ams:'_..l n Search>Are.. ';n Wt>APPOCation Detail
FL 9 FL16027-RI
Application Type Revision
Code Version 2014
Application Status Approved .
Camar�ai>
Archived
Product Manufacturer Tri-Built Materials Group,LLC
Address/Phone/Email - PO Box 70
Rutherford,{VI 07070 .
(800)516-1485
davd_ru¢gtribuiltmg.com
Authorized Signature David Ruiz
david,ru iz@tribu iltmg.com
Technical Representative C Richard Schurman
Address/Phone/Email 9050 Louisiana Street
V--riillwille,IN 46410
titer.. awanfrr1e%E ¢''l1TsgAwn
Quality Assurance Representative C Richard Schurman
Address/Phone/Emad _ 9050 Louisiana Street
Mesr01vr11e,IN 46410
rich"schurman%aUtedbuilding.com
. Category Ronfrng
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
;,.r. Evaluation Report-Hardcopy Received
Fiorzda Engmeeer er Arcitlect It!TMm=tho devecipEd tde2 Rebatt der€usn
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 03/31/2019
Validated By John w.Knezerirh,PE
`r Varudation Cheddrst-Hardcopy Received
Certificate of Independence FL16027 R1 COI 201S 01 COI Nieminen.odf
Refem-1ced Standard and Year(of Standard) Standard Year
AST14 06163 2000
AST&i D5164 2005
ASTM7 D6222 2008
FM 4470 1992 -
FM 4474 2004
Equivalence of Product Standards
Certified By
Sections from the Code
http://w,.ww.floridabuilding.org/pr/pr_app dtl.aspx?param=wGEVXQwtDgtFPmdYiNDWr--- 1/30/2017
v.
t n e
IN ERD
APPENDIX 1;ATTACHMENT REQUIREMEN75 FOR WIN®UPLIFT RESISTANCE'
Table Deck Application Type Dascrlption Page
SA-1 Wood New or Reroof(Tear-Off) A-2 Mech,Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 4
1A-2 Wood New,Reroof(Tear-Off)or Recover A-2 Mach.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 5
iB Wood Now,Reroof(Tear-Off)or Recovor B Mech,Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 5
IC Wood New,Reroof(Tear-Off)or Recover C Mech,Attached Insulation,Bonded Roof Cover 6
1D Wood Now,Reroof(Tear-Off)or Recovor D Prollm,Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover 6
SE-1 Wood New or Reroof(Tear-Off) E Non-Insulated,Mech,Attached Base Shoot,Bonded Roof Cover 7
3E-2 Wood New,Reroof(Tear-Off)or Recover E Non-Insulated,Mech,Attached Base Shoot,Bonded Roof Cover 8
IF Wood Now or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 8
_2A Steel or Conc. New,Reroof(Tear-Off)or Recover B Moch,Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 9
2B Steel or Conc. New,Reroof(Tear-Off)or Recover C Mach.Attached Insulation,Bonded Roof Cover 10
2C Steel or Conc. Now,Reroof(Tear-Off)or Recover D Prelim,Attached Insulation,Mech.Attached Base Sheet,Bonded Roof Cover it
3A-1 Concrete New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 12-14
3A-2 Concrete New or Reroof(Tear-Off) A-1 Bonded Temporary Roof,Bonded Insulation,Bonded Roof Cover 15
3B Concrete New or Reroof(Tear-Off) F Non-Insulated,Bonded Roof Cover 15
4A LWIC New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 16-17
46 LWIC Now or Reroof(Tear-Off) A-2 Mach.Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 17
4C LWIC Now or Reroof(Tear-Off) E Non-Insulated,Mech,Attached Base Shoot,Bonded Roof Cover 18-20
SA CWF New or Reroof(Teae-Off) A-1 Bonded Insulation,Bonded Roof Cover 21
5B CWF New,Reroof(Tear-Off)or Recover A-2 Mach,Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 22
5C CWF New,Reroof(roar-Off)or Recover B Mech,Attached Base Insulation,Bonded Top Insulation,Bonded Roof Cover 22
5D CWF New,Reroof(Tear-Off)or Recovor C Mach,Attached Insulation,Bonded Roof Cover 23
5E CWF Now,Reroof(Tear-Off)or Recover E Non-Insulated,Mech,Attached Base Shoot,Bonded Roof Cover 23
6A Gypsum New or Reroof(Tear-Off) A-1 Bonded Insulation,Bonded Roof Cover 24
68 Gypsum New,Reroof(Tear-Off)or Recovar A-2 Mach,Attached Anchor Sheet,Bonded Insulation,Bonded Roof Cover 25
6C Gypsum New,Reroof(Tear-Off)or Recovar C Moch.Attached Insulation,Bonded Roof Cover 25
6D Gypsum New,Reroof(roar-Off)or Recovar E Non-Insulated,Mech,Attached Base Shoot,Bonded Roof Cover 25
7A Various Recover A-1 Bonded Insulation,Bonded Roof Cover 26-27
78 Various Recover F Non-Insulated,Bonded Base Sheet,Bonded Roof Cover 27
Thaollown nots aoaiv tothe se vjgMs outlinen heroin;
1. The roof system evaluation herein pertains to above-deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the AHJ, Load resistance of the
roof deck shall be documonted through proper codified and/or FBC Approval documuntatlon,
2, insulation/base sheet fasteners shall be of sufficient length for the following deck engagement:
Y Wood; Minimum 0J5-Inch penetration.
Y Steel; Minimum 0,75-Inch penetration and engage the top flute of the steel deck.
Y Concrete; Minimum 1-Inch embedment Into pilot hole In accordance with fastener manufacturer's published installation instructions,
3. Unless otherwise noted,Insulation may be any one layer or combination of polyisocyanurate,polystyrene,wood fiberboard,perlite,Dens Dock,Dens Deck Prime,SECUROCK Gypsum-Fiber Roof Board or SECUROCK
Glass-Mat Roof Board that meets the QA requirements of F.A.C,Rule 61G20-3 and is documented as meeting FBC 1505.1 and,for foam plastic,FBC 2603,4.1 or 2603.6,when installed with the roof cover,
Exterior Research and Design,I.I.C.d/b/a Trinity)ERD Evaluation Report A42970,10,12-R1 for FL16027-R1
Certificate of Authorization H9503 Revision 1:03/23/2015
Prepared by; Robert Nieminen,PE-59166 Appendix 1,Page 1 of 27
4. Minimum 200 psi,minimum 2-Inch thick lightweight insulating concrete may be substituted for rigid Insulation board for System Type D(mechanically attached base sheet,bonded roof cover),whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be In accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
5. Unless otherwise noted,Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application;the ribbons/beads shall expand as noted In the manufacturer's published Instructions.
HA(HA): Full coverage at 25.30 ibs/square.
y Dow Insta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-Inch wide ribbons,l2-Inch o.c.
Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0,5-Inch wide ribbons,12-Inch o.c.
L OMG OlyBond 500(08500): Continuous 0.75 to 1-Inch wide ribbons,l2-Inch o.c.(PaceCart or SpotShot), Note., OlyBond Green may be used where OlyBond 500 is referenced
OlyBond Classic(00 Classic): Full coverage at 1 gal/square.
r 3M CR-20: Continuous 2.5-15-Inch wide ribbons,12-Inch o.c.
v Note: When multiple loyers(s)of insulation and/or coverboard are installed In ribbon-applied adhesive,adhesive ribbons shall be staggered from layer-to-layer a distance of one-half the ribbon spacing,
i Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing,
6. Unless otherwise noted,all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya nu rate at the following thickness limitations may be substituted with the following Maximum
Design Pressure(MDP)limitations. In no case shall these values be used to'increase'the MDP listings In the tables;rather If MOP listing below meets or exceeds that listed for a particular system in the tables,then
the thinner board listed below may be used as a drop-in for the equivalent thicker material listed in the table:
r Millennium One Stop Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min.0.5-inch thick)
Y OMG OlyBond 500(0B500): MDP -45.0 psf (Min.0.5-inch thick Multi-Max FA-3)
Y OMG OlyBond 500(08500): MDP -187.5 psf (Min,0.5-inch thick ISO 95+GL)
}%OMG OlyBond S00(08500): MDP -315.0 psf (Min,0.5-inch thick ENRGY 3)
OMG OlyBond 500(08500): MDP 487.5 psf (Min.0.5-inch thick ACFoam II)
i 3M CR-20: MDP -117.5 psf (Min.1.0-inch thick)
7. Bonded polylsocyanurato Insulation boards shall be maximum 4 x 4 ft.
S. For mechanically attached components or partially bonded insulation,the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16,and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked with an asterisk"carry the limitations set forth In Section 2.2,1,5,1(a)of FM LPDS 1.29 for Zone 2/3 enhancements.
9. For fully bonded assemblies,the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined In accordance with FBC Chapter 16,and no rational analysis Is permitted.
10, For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be In accordance with TAS 105 or ANSI/SPRI FX-1.
11, For existing substrates in a bonded recover Installation,the existing roof system shall be examined for compatibility and bond performance with the selected adhesive,and the existing roof system shall be capable of
resisting project design pressures on its own merit to the satisfaction of the AHJ,as documented through field uplift testing in accordance with ASTM E907,FM LPDS 1.52,ANSI/SPRI IA-1 or TAS 124.
12. For Recover Applications using System Typo D,the Insulation is optional;however,the existing roof system shall be suitable for a recover application,
13, LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC Is referenced,refer to current LWIC Product Approval for specific deck
construction and limitations, For systems where specific LWIC Is not referenced,the minimum design mix shall be 300 psi. In all cases,the minimum top-coat thickness Is 2-inches. For LWIC over structural concrete,
reference Is made to FBC Section 1917.4.1,Point 1.
Exterior Research and Design,I.I.C.d/b/a Trinity)ERD Evaluation Report A42970.10.12-113 for FL16027-Ri
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 2 of 27
r
I VI ER®
14, Unless otherwise noted,refer to the following references for bonded base,ply or cap sheet applications,
TA®Le'3 TRI BUILT RooF COVEN
Reference Layer Material Application
BP-AA Base FBC Approved ASTM D4601,Type II
HA at 20.40 Ibs/square
(Base and Ply shoots,Asphalt-Applied) Ply FBC Approved ASTM D2178,Type IV or VI
SBS-AA Cap TriBullt SBS Granular
(SBS,Asphalt-Applied) HA of 20 40 Ibs/square
SBS-TA Cap TriBullt SBS Granular Torch-Applied
(SBS,Torch-Applied)
SBS-SA Base TriBuilt SA SBS Base Self-Adhering
(SBS,Self-Adhering) Cap TriBullt SA SBS Cap
APP-TA Base or Ply TrlBullt APP Smooth
Torch-Applied
(APP,Torch-Appllod) Cap TriBuilt APP Smooth,TriBullt APP Granular
APP-SA Cap TriBullt SA APP Cap
Salf-Adhering
(APP,Self-Adhering)
15. The following represent priming requirements for gypsum-based coverboards:
r Dens Deck and Dons Deck Prime shall be field-primed with ASTM D41 primer prior to self-adhering or torch-applied membrane application. No priming is required for hot-asphalt membrane applications,
i SECUROCK Gypsum-Fiber Roof Board does not require field priming for any membrane application.
16. "MDP"=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads.Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design,LLC.d/b/a Trinity)ERD Evaluation Report A42970,10.12-113 for FL16027-R1
Certificate of Authorization 119503 Revision 1:03/23/2015
Prepared by, Robert Nieminon,PE•59166 Appendix 1:,Page 3 of 27
ERD
TABLE 1A-1:WOOD DECKS—NEW CONSTRUCTION oR REROOF(TEAR-OFF)
SYSTEM TYPE A-2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Dock Anchor Sheet Base Insulation Top Insulation Roof Cover MDP
No. (See Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (psf)
Min.0.25-Inch Dens
Polyglass G2 Base, 8-Inch o.c.in 4• Dock,Dens Deck Prime,
Min.19/32- CortainTeed Glasbaso, 32 ga.,1-5/8- Inch lap and 8• (Optional)FBC SECUROCK Gypsum-
Inch plywood Firestone MB Base,JM Inch diameter Inch o,c.in Approved, Fiber Roof Board,Min. SBS-AA,
(Optional)
W-i a4 max.24- Parma-Ply 28,Tamko BP-AA tin caps with 11 three,equally ASTM C1289, HA 0.75-Inch FescoBoard HA BP-AA SBS-TA, -60.0
Inch spans Glass Base or ga,annular ring spaced, type II polyiso• (homogeneous)or min, APP-TA
GAFGLAS 075 shank nails staggered cyanurate 0.5•Inch Structodek
center rows High Density Fiberboard
Roof Insulation
Polyglass G2 Base, 8-Inch o.c.in 4-
Min.19/32- CortainToed Glasbaso, 32 ga.,1-5/8- Inch lap and 8- (Optional)FBC Min.0,25•inch Dens (Optional) SBS-SA,
Inch diameter Inch o.c.in Approved, One or
Inch plywood Firestone MB Base,1M Deck Dens Deck Prime, APP-SA,
a4 max.24- Perma-Ply 28,Tamko SECUROCK Gypsum- SBS-TA or
W-2 tin caps with 11 three,equally ASTM C1289, HA HA SBS-SA Moro SBS- -60.0
ga.annular ring spaced, type II polyiso- SA or
Inch spans Glass Base or shank nails staggered cyanurate Fiber Roof Board APP-TA APP-TA
GAFGLAS it75 center rows
6-Inch o.c,in 4• Min,2-inch D-IS,OB500,
32 go.,1-5/8- Inch lap and 6-
Min.19/32- ACFoam 11,III, CR•20 or M- Min,0,25•inch Dens D•IS,
Polyglass Elastobase Inch diameter Inch o,c,in SBS-AA,
Inch plywood H-Shield,H- OSFA,atop Deck,Dons Deck Prime 08500, (Optional)
W-3 or Polyglass tin caps with 12 four,equally BP-AA SBS-TA, -60.0
at max.24• Elastobase PolyShield CG, fastener or SECUROCK Gypsum- CR-20 or BP-AA
Inch spans go,annular ring spaced, Multi-Max FA3 rows,7-inch Fiber Roof Board M•OSFA APP-TA
shank nails staggered
or ENRGY-3 oc
center rows
6-inch o.c.in 4• Min,2-inch' D-IS,08500,
32 Ga.,1-5/8- Inch lap and 6- (Optional}
Min.19/32- ACFoam II,III, CR•20 or M- D-IS, SBS-SA,
Polyglass Elastobase inch diameter Inch o.c.in One or
Inch plywood H•Shicid,H- OSFA,atop (Optional)Additional OB500, APP-SA,
W-4 or Polyglass tin caps with 12 four,equally SBS-SA more SBS- -60.0
at max.24- Elastobase PolyShield CG, fastener layers of base insulation CR-20 or SBS-TA or
Inch spans go,annular ring spaced, Multi-Max FA3 rows,7-inch M-OSFA SA or APP-TA
shank nails staggered APP-TA
center rows or ENRGY-3 ac
Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report A42970.10,12-Ri for FL36027-R1
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 4 of 27
.w.xy r'''^' i
INITY
RD
TABLE lA•2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)oR RECOVER
SYSTEM TYPE A•2:MECHANICALLY ATTACHED ANCHOR SHEET,BONDED INSULATION,BONDED ROOF COVER
System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover MDp
No. (See Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Cap (Psf)
12-Inch o.c,in 4- Min.0,25-Inch Dens Deck,
Min,19/32- OMG Flat Inch lap and 12-
Polyglass (Optional)FBC Dens Dock Prime,SECUROCK
Elastobase or Approved, Gypsum-Fiber Roof Board,
Inch plywood Bottom Plates Inch o,c.In two, (Optional) SBS•AA,SBS-
W-5 PolYBlass ASTM C1289, HA Min.0,75•inch FescoBoard HA BP-AA •60.0
In max, Elastobase (square)with equally spaced, type II polyiso- (homogeneous)or min.0.5- BP AA TA,APP TA
Inch spannss Poly Roofgrip f112 staggered center cyanurate Inch Structodek High Density
rows Fiberboard Roof Insulation
Polyglass 12•Inch o,c,in 4-
(Optional)FBC (Optional)
Min,19/32 Elastobase or Approved,OMG Flat Inch lap and 12- Min.0,25-Inch Dens Deck, One or SBS-SA,APP•
Inch plywood Bottom Plates Inch o,c.In two,
W-6 Polyglass ASTM C3289, HA Dens Dock Prime,SECUROCK HA SBS-SA more SBS• SA,SBS-TA -60,0
at max,24- Elastobase (square)with equally spaced, type II polyiso- Gypsum-Fiber Roof Board SA or APP- or APP-TA
Inch spans Poly Roofgrlp#12 staggered center cyanurate TA
rows
TABLE 10:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE B:MECHANICALLY ATTACHED BASE INSULATION,BONDED TOP INSULATION,BONDED ROOF COVER
System Deck(See Note 1) Base Insulation Layer Top Insulation Layer Roof Cover MDP
No. Type Fasteners Attach Type Attach Base Ply Cap (psi)
0.75•Inch FescoBoard
Min.19/32-inch Min.1.5•Inch -Dekfast Hex with Min. (Optional if (Optional if using
W 7 1 per (homogeneous)or.min.0.5-Inch AA Base)One or SBS•AA,SBS-TA
plywood at max,24•Inch ENRGY 3 H•Shiold Dekfast#12 or TruFasc a HA using AA Ply) -6010
spans or Polythorm MP-3 with TruFast DP 1.33 ft Structodek High Density Fiberboard BP•AA more BP-AA or APP-TA
Roof Insulation APP-TA
Exterior Research and Design,LLC,d/b/a Trinityl ERD Evaluation Report A42970.10.12-R3 for FL16027-R1
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 5 of 27
TRINITY?ERD
TABLE IC:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE C:MECHANICALLY ATTACHED INSULATION,BONDED ROOF COVER
System Dock(See Note 1) Base Insulation Top Insulation Layer Roof Cover MOP
o
Type Fasteners Attach Base Ply Cap (psf)
(Optional) Min,0.5-Inch Structodek High Density
Min.19/32-inch Dekfast Galvalume (Optional if (Optional if using AA
One or more layers, Fiberboard Roof Insulation or min,0.25• 1 per 1.33 SBS-AA,SBS-TA,APP-
W-8 plywood at max. Steel Hex with � using AA Ply) Base)One or more BP-AA -82.5
any combination, Inch Dens Deck,Dens Deck Prime or ft TA
24-Inch spans loose laid SECUROCK Gypsum-Fiber Roof Board Dekfast H12 DP BP-AA or APP-TA
(Optional) Dekfast Galvalume
Min.19/32-inch Steel Hex with
W-9 plywood at max. One or more layers, Min.1.5-inch ENRGY 3,H-Shield or Dekfast q12 DP or 1 Per 1,33 SBS-SA (Optional)One or more SBS-SA,APP•SA,SBS• _82 5
2lywoo spans any combination, Polytherm Dekfast
TruFast 1112 with ft SBS-SA or APP-TA TA or APP•TA
loose laid TruFast DP
TABLE ID:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE D:PRELIMINARILY ATTACHED INSULATION,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER
System Dock(Soo Note 1) insulation Layer(s) Base Sheet Roof Cover MOP
No. Type Attach Base Fasteners Attach Ply Cap (psf)
Polyglass Elastobaso,Polyglass OMG Flat Bottom Plates
Min.19/32-inch One or more layers, Prelim Elastobase Poly,Polyglass G2 Base, (square)with Roofgrip 12-inch o,c,In 4-Inch lap and 12- (Optional)One SBS-AA,
.
W-10 plywood at max. CertalnTeed Giasbase,Firestone MB 014,Dekfast Hex with inch o.c.In two,equally spaced, or more BP-AA SBS-TA, -52.5
24•inch spans any combination Attached Base,1M Perma-Ply 28,Tamko Glass Dekfast$114 or TruFast staggered center rows or APP-TA APP-TA
Base or GAFGLAS H75 MP-3 with TruFast HD
Min.19/32-inch Dekfast Hex with Dekfast 12-inch o,c.In 4-Inch lap and 12-
SBS-SA,
W-11 plywood at max. One or more layers, Prelim. Polyglass Elastobaso or Polyglass #14 or TruFast MP-3 with inch o,c,In two,equally spaced, One or more APP-SA, -52.5*
24=Inch spans any combination Attached Elastobase Poly with poly top surface TruFast HD staggered center rows SOS-SA SBS-TA or
APP-TA
Min,19/32-inch 12-inch o.c,in 4-Inch lap and 12- (Optional)One SBS-AA,
One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates
W-12 plywood at max, inch o.c.In two,equally spaced, or more BP-AA SBS-TA, -60.0
24-Inch spans any combination Attached Elastobase Poly (square)with Roofgrip t112 staggered center rows or APP-TA APP-TA
Min.19/32-inch 12-inch o,c,in 4-Inch lap and 12• SBS-SA,
One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates One or more APP-SA, +
W-13 plywood at max. any combination Attached Elastobase Poly with poly top surface (square)with Roofgrip N12 inch o.c.In two,equally spaced, SBS-SA SBS-TA or -60,0
24•Inch spans staggered center rows 12
Exterior Research and Design,I.I.C.d/b/a Trinity)ERD Evaluation Report A42970.10.12-111 for FL16027-RI
Certificate of Authorization 119503 Revision 1:03/23/2015
Prepared by: Robert Nieminen,PE-59166 Appendix 1,Page 6 of 27
TABLE SE-1:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE E:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER
System Deck(See Note 1) Base Sheet Roof Cover MDP
No. Base Fasteners Attach Ply Cap (Psf)
Min,IS/32-inch
W-14 plywood at max,24• Polyglass Elastobase Simplex MAXX Cap 9-inch o,c,at 2-Inch lap and 18•Inch o,c,in two, (Optional)BP-AA or SBS•AA,SBS•TA -45,0'
Inch spans equally spaced,staggered cantor rows APP-TA or APP-TA
Min,15/32-inch 9-inch o,c,at 2-Inch la and 12-Inch o,c.In two,
W-15 plywood at max.24- Polyglass Elastobase Simplex MAXX Cap P {Optional)BP-AA or SBS•AA,585•TA -52.5
Inch spans equally spaced,staggered center rows APP-TA or APP-TA
Min, inch
Polyalass Elastobase,Polyglass Elastobase (Optional)One or
Poly,Polyglass G2 Base,CertainTaod 32 ga.,1-5/8-Inch diameter tin caps 8-inch o,c,In 4-Inch lap and 8-Inch o,c,In three, SBS•AA,SBS-
W-16 plyw000dd a at t max, Glasbase,Firestone MB Base,JIM Perm- with 11 on,annular ring shank nails equally spaced,staggered center rows more BP AA or TA,APP-TA G0,0
24-inch spans Ply 28,Tamko Glass Base or GAFGLAS k75 APP-TA
Min.19/32-inch Polyglass Elastobase or Polyglass 32 ga.,1-5/8-inch diameter tin cops 8-inch ox,in 4-inch lap and B•Inch O.C.in three, (Optional)One or SBS•SA,APP-
W-17 plywood at max, Elastobase Poly with poly top surface with 11 go,annular ring shank nails equally spaced,staggered canter rows more SBS-SA or SA,SBS-TA or G0,0
24-Inch spans APP-TA APP•TA
Min.15/32-inch 6-inch o,c,at 2-Inch la and 6-Inch o.c,In two,
W-18 plywood at max.24- Polyalass Elastobase Simplex MAXX Cap p (Optional)BP-AA or SBS•AA,SBS-TA -90.0
Inch spans equally spaced,staggered cantor rows APP•TA or APP-TA
Min.19/32-inch Polyglass Elastobase or Polyglass 32 ga.,1-5/8-Inch diameter tin caps 4-inch ox.In 4-Inch lap and 4-Inch C.in four, (Optional)One or SBS-SA,APP-
W-19 plywood at max, Elastobase Poly with poly top surface with 11 go,annular ring shank nails, equally spaced,staggered center rows more SBS-SA or SA,SBS-TA or 97,5
24-Inch spans APP•TA APP-TA
plywood
t inch 64nch ox,at 2-Inch la and 6-Inch o.t.In three,
W-20 plywood at max,24- Polyglass Elastobase Simplex MAXX Cap P (Optional)BP-AA or SBS•AA,SBS-TA .105.0
Inch spans equally spaced,staggered cantor rows APP•TA or APP-TA
Min,19/32-inch (Optional)One or
W-21 plywood at max, Polyalass Elastobase or Polyglass 32 ga.,1.5/8•inch diameter tin caps 6-inch o,c,in 4-Inch lap and 6-Inch o,c,In four, SBS-AA,SBS-
P y Elastobase Poly with 11 go,annular ring shank nails equally spaced,staggered tenter rows more BP-AA or TA,APP-TA •112.5
24-Inch spans APP•TA
Min,19/32-inch 32 ga.,1-5/8-inch diameter tin caps SBS-SA,APP-
W-22 plywood at max. Polyglass Elastobase or Polyglass with 11 go.annular ring shank nails. 6-inch ox,in 4-Inch lap and G=Inch o.c.In four, (Optional)One or SA,SBS-TA or -112.5
24-Inch spans Elastobase Poly with poly top surface Note:Tin caps are to be primed with equally spaced,staggered cantor rows more APP-TA ApP.TA
ASTM D41 primer.
Exterior Research and Design,LLC.d/b/a Trinity(ERD Evaluation Report A42970.30.12-R1 for FL16027•Rl
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by; Robert Nieminen,PE-59166
Appendix 1,Pape 7 of 27
s
...,.. ` TRINITY I ERR
TABLE 1E•2:WOOD DECKS—NEW CONSTRUCTION,REROOF(TEAR-OFF)OR RECOVER
SYSTEM TYPE E:NON-INSULATED,MECHANICALLY ATTACHED BASE SHEET,BONDED ROOF COVER
System Base Sheet Roof Cover
Deck(See Note 1) MDP
No. Base Fasteners Attach Ply Cap (psf)
Min.19/32-inch Polyglass Elastobase,Polyglass Elastobase
Poly,Polyglass G2 Base,CertainTaed OMG Flat Bottom Plates(square)with 12•Inch o.c.in 4-inch lap and 12-inch (Optional)One or SBS-AA,SBS-
W-1 plywood at max. Glasbaol Firestone se Base,JM Perma- Roofgrip 414,Dekfast Hex with Dekfast#14 o.c.In two,equally spaced,staggered more BP-AA or TA,APP-TA -52,5
24-Inch spans Ply 28,Tamko Glass Base or GAFGLAS#75 or 7ruFast MP-3 with TruFast HD center raves APP•TA
Min.19/32-inch Polyglass Elastobase or Polyglass Dekfast Flex with Dekfast#14 or TruFast MP- 12-Inch o.c.in 4-inch lap and 12-inch SBS-SA,APP-
W-2 plywood at max, Y8 Yg o,c,In two,equally spaced,staggered One or more SBS• SA,SBS-TA or -52.54
24-inch spans Elastobase Poly with poly top surface 3 with TruFast HD SA
P canter rows APP•TA
Min.19/32-inch 12-Inch o.c,in 4-inch lap and 12-inch (Optional)One or
W-3 plywood at max. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates(square)with o,c.In two,equally spaced,staggered more BP-AA or SBS-AA,SBS- -60.0
24-Inch spans Elastobase Poly Roofgrip 1112 center rows APP•TA TA,APP-TA
Min,19/32-inch Pol lass Elastobase or Polyglass OMG Flat Bottom Plates(square)with 12•Inch o.c,in 4-inch lap and 12-inch SBS-SA,APP-
W-4 plywood at max, Yg Yg (q ) ox,In two,equally spaced,staggered One or more SBS- SA,SBS-TA or -60,0*
24-Inch s ans Elastobase Poly with poly top surface Roofgrip 1112 SA
p center rows APP-TA
TABLE IF:WOOD DECKS—NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE F:NOWINSULATED,BONDED ROOF COVER
System Deck Primer Roof Cover MOP
No. Joint Treatment Base Ply Cep (psf)
W-5 Min,15/32-inch plywood )(Optional SBS-SA or SBS-SA,APP-SA,SBS-TA
at max.24-inch spans (Optional)ASTM D41 None SBS-SA APP-TA or APP-TA -90,0
W 6 Min.15/32-inch plywood (Optional)ASTM D41 Plywood joints are covered with 4-inch wide strips of TriBuilt SA TrlBuilt SA SBS Base (Optional)SBS-SA or SBS-SA,APP-SA,SBS-TA •97 5
at max,24-inch spans SBS Base,rolled into place to create continuous bond, APP-TA or APP•TA
Exterior Research and Design,I.I.C.d/b/a Trinity(ERD Evaluation Report A42970.10.12-R3 for FL16027-RI
Certificate of Authorization#9503 Revision 1:03/23/2015
Prepared by, Robert Nieminen,PE-59166 Appendix 1,Page 8 of 27