HomeMy WebLinkAboutProject Information a Bruce Bussell
Palm Engineering Manager
Na.1bol Palm Harbor Homes,Inc.
. 605 South Frontage Road
Plant City,Florida 33563-9934
Phone:813-752-1368 Ext.756
Fax 1:813-754-8675
omen
Fax 2:813-719-3689
E-Mail:bbussell@palmharbor.com
March 22,2017
To: Building Department
RE: Palm Harbor Home, Serial Number#20745, Model 340TL28532C
Savanna Club, Site#7501
Dear Plans Examiner,
The site-beam, which was installed by Palm Harbor Homes, and is approved by HUD,
Manufactured Home Construction& Safety Standards, is constructed to receive on-site
additions that are built and designed by others to accommodate such amenities as
carports, sheds, and screen rooms. The on-site structure must be designed by a Florida,
registered, engineer,to the Florida Building Code and all local codes. This plant-
installed site beam is of adequate design for this purpose as long as tie downs and piering
are per page 1 of Section 11,Misc. &Final Inspection section of the installation manual
(attached). The attached details, EW-216.2 and PA69-EW-31, are approved by the
Manufactured Home Construction& Safety Standards. And,the design loads for the
plant-installed site beam, as well as the supporting structure and anchorage are from the
FBC and ASCE 7.
I can be of further assistance at the above contact information.
Sincerely yours,
Bruce Bussell
Engineering Manager
Palm Harbor Homes
L �. r
ti
Option 9: using 2x4 let-in into dadoed 2x6 wall stud
Metal Flet Typ.Truss.
2x4#3 S-P-F L oWn
'Fasten into each wall stud
with 0 as.0.131%X nails.
Roof Parcel _ or 6-ea 711 W 1 r&15ga
Secure Roof Panel Handw staples.Alt.-4#OX3-screws
Into 2K4 as approved by
tfte..manufac*ire s
trsslindon h arts: appr+o d sheathing
i.e.;Thermoply.Thermosheath
Root Planet Head OSS or Plywood.
Lop Race
Lap Siding bate Caulk
TUTVVgl�:s�4.
John c.ooeclen, p I=.
K EnglZeeK19. One.
Opt+on .2: using 2_z4 installed on top of sheathing
and exterior wall studs
Aluminum ftt stork
Typ:Tru. shaped around 2x4
and serxved Into soffit
and g.w/metal
screws.
Roof Panel 2x,4 ft S-P-F
Fasten:Irft each wall stud
Soo"FtoW Panel Header with 4 ea.#8idr scre+ &
Into 2x4 as approved by
tt ntanufacturees
Inslaaltation Instrudkm.
Roof Pen®i Header approved sheathing
Silkxute Caulk ""�-4 I.e..Thenngpiy.Thermoshe h
Lop Receive OSB or Ptyaroad.
l:ap'Siding
lSCorpVED PALM HARBOR HOMES INC.
PFS Corporation ,
Madison, W1 1 15303 DALL4S PARKWAY. _SUITE 800. ADDISON. TX 75001
OCT 0 3 2000 Screen room and Carport attachment DAM09/18/00
Factory prop options. pM NO.
HUD.Manufactured-Home
Construction& EW - 215.2
WIND ZONE 2&3
cad-r12
4