Loading...
HomeMy WebLinkAboutProject Information a Bruce Bussell Palm Engineering Manager Na.1bol Palm Harbor Homes,Inc. . 605 South Frontage Road Plant City,Florida 33563-9934 Phone:813-752-1368 Ext.756 Fax 1:813-754-8675 omen Fax 2:813-719-3689 E-Mail:bbussell@palmharbor.com March 22,2017 To: Building Department RE: Palm Harbor Home, Serial Number#20745, Model 340TL28532C Savanna Club, Site#7501 Dear Plans Examiner, The site-beam, which was installed by Palm Harbor Homes, and is approved by HUD, Manufactured Home Construction& Safety Standards, is constructed to receive on-site additions that are built and designed by others to accommodate such amenities as carports, sheds, and screen rooms. The on-site structure must be designed by a Florida, registered, engineer,to the Florida Building Code and all local codes. This plant- installed site beam is of adequate design for this purpose as long as tie downs and piering are per page 1 of Section 11,Misc. &Final Inspection section of the installation manual (attached). The attached details, EW-216.2 and PA69-EW-31, are approved by the Manufactured Home Construction& Safety Standards. And,the design loads for the plant-installed site beam, as well as the supporting structure and anchorage are from the FBC and ASCE 7. I can be of further assistance at the above contact information. Sincerely yours, Bruce Bussell Engineering Manager Palm Harbor Homes L �. r ti Option 9: using 2x4 let-in into dadoed 2x6 wall stud Metal Flet Typ.Truss. 2x4#3 S-P-F L oWn 'Fasten into each wall stud with 0 as.0.131%X nails. Roof Parcel _ or 6-ea 711 W 1 r&15ga Secure Roof Panel Handw staples.Alt.-4#OX3-screws Into 2K4 as approved by tfte..manufac*ire s trsslindon h arts: appr+o d sheathing i.e.;Thermoply.Thermosheath Root Planet Head OSS or Plywood. Lop Race Lap Siding bate Caulk TUTVVgl�:s�4. John c.ooeclen, p I=. K EnglZeeK19. One. Opt+on .2: using 2_z4 installed on top of sheathing and exterior wall studs Aluminum ftt stork Typ:Tru. shaped around 2x4 and serxved Into soffit and g.w/metal screws. Roof Panel 2x,4 ft S-P-F Fasten:Irft each wall stud Soo"FtoW Panel Header with 4 ea.#8idr scre+ & Into 2x4 as approved by tt ntanufacturees Inslaaltation Instrudkm. Roof Pen®i Header approved sheathing Silkxute Caulk ""�-4 I.e..Thenngpiy.Thermoshe h Lop Receive OSB or Ptyaroad. l:ap'Siding lSCorpVED PALM HARBOR HOMES INC. PFS Corporation , Madison, W1 1 15303 DALL4S PARKWAY. _SUITE 800. ADDISON. TX 75001 OCT 0 3 2000 Screen room and Carport attachment DAM09/18/00 Factory prop options. pM NO. HUD.Manufactured-Home Construction& EW - 215.2 WIND ZONE 2&3 cad-r12 4