Loading...
HomeMy WebLinkAboutTANKLESS WATER HEATER Rlllllal. RU19915 i • SEINSEV CONDENSING HEATER RESIDENTIAL SUPER-HIGH-EFFICIENCY(CONDENSING) Am TANKLESS WATER HEATER Installation Type Internal(Indoor)Residential Applications.Manufactured(Mobile) Home Certified Model Numbers RU199i(REU-N3237FF-US) RU180i(REU-N2934FF-US) RU160i(REU-N2530FF-US) RU130i(REU-N2024FF-US) Approved Gas Types Natural and Propane Uniform Energy Factor(UEF) RU199i,RU180i,RU160i: 0.93 RU130i: 0.91 Energy Factor(EF) RU199i: 0.96 (Canada) RU180i,RU160i,RU130i: 0.95 High Altitude Approved Up to 10,200 ft(3,109 m) Water Flow Control Water Flow Sensor,Electronic Water Control and Bypass Control ■ FLEXIBLE VENTING OPTIONS Controller Standard: Integrated Controller Optional:MC-195T-US,MC-100V-1US, • Concentric or Schedule 40 PVC/CPVC BC-100V-1US,MCC-91-2US • Direct Vent(Concentric and Twin Pipe) Certifications AHRI,ANSI Z21.10.3,CSA 4.3,and • Non-Direct Vent(Room Air) ENERGY STAR° • Common Vent(Direct Vent and Room Air) Warranty • Maximum Equivalent Vent Lengths: • Heat Exchanger:15 years or 12,000 operation hours,whichever Twin Pipe occurs first Vent Sizes 2 in.(51 mm) 3 in.(76 mm) • All Other Parts and Components:5 Years Vent Lengths 65 ft(20 m) 150 ft(46 m) • Reasonable Labor: 1 Year Concentric Safety Devices Vent Sizes 2 in.X 4 in. 3 in.X 5 in. Flame Failure-Flame Rod,Boiling Protection,Combustion Fan RPM Check,Over Current-Glass Fuse, Remaining Flame(OHS)and Vent Lengths 65 ft(20 m) 150 ft(46 m) Automatic Frost Protection Included with Purchase ■ EASE OF INSTALLATION AND Tankless Water Heater,Wall Mounting Bracket,Pressure Relief Valve SERVICEABILITY and Adapter,Isolation Valve Kit,Vent Screens(x2),Vent Screen Screws(x2)and Self-Tapping Screws(x2) • Compact Design to Save Space Additional Features • Wi-Fi Technology for Remote Monitoring and Management • Sliding Mounting Bracket for Easy Installation • Mobile Home Certified • Ultra Low NOx • Complies with South Coast • Tankless Rack SystemT""Compatible • Simple Gas Conversion Air Quality Management • 1/2 in.(13 mm)Gas Line Compatible District 14 ng/J or 20 ppm NOx Emission Levels ■ OPTIONAL ACCESSORIES Room Air Screen,Condensate Neutralizer,ScaleCutter,Drain (E' Down Kit,Additional Controllers, Pi e Cover,Recirculation °Pump, DPS/MIS Switch,EZConnectT""Cables,Control-RT" CERTIFIED Low LEAD SANITATION Wi-Fi Module,Wireless Accessories,and many more. CONTENT Visit rinnai.us for a complete list of accessories. CERTIFIED TO ANSI Z21.10.3 - CSA 4.3 RINNALUS • 1-800-621-9419 SENSEITm TECHNICAL • in.(mm) SPECIFICATION RU199i RU180i RU160i RU130i FRONT 5.90 Dimensions-w,h,d 18.5 in.x 26.4 in.x 11.4 in. (470 mm x 670 mm x 290 mm) (150) Minimum Gas 15,000 1 Consumption Btu/h Maximum Gas o 199,000 180,000 160,000 130,000 0 Consumption Btu/h �M S Flow Rate' 0.26-9.8 GPM 0.26-9.0 GPM 0.26-8.0 GPM 0.26-6.6 GPM (Min-Max) (1.0-37 L/min) (1.0-34 L/min) (1.0-30 L/min) (1.0-24 L/min) Max Flow Rate with 11 GPM 10 GPM 9 GPM 7 GPM Parameter Adjustment (42 L/min) (38 L/min) (34 L/min) (26 L/min) cD co Weight 64 lb(29 kg) 64 lb(29 kg) 62 lb(28 kg) 62 lb(28 kg) o M Sound Level 48 dB 47 dB 47 dB 47 dB N Normal 84 W 65 W 52 W 38 W Standby 1.3 W � Freeze Protection 148 W $e v w Max Current 4 Amps Fuse 10 Amps 18.5 • Minimum: 98°F(37°C) Default (470) Temperature • Maximum: 120°F(49°C)Default SIDE 140°F(60°C)With Parameter Adjustment 6.08 By-Pass Flow Control Electronic (154) Vent Connection: Gas Supply Pressure • Natural: 3.5 in.w.c.-10.5 in.w.c. 1-7 pp y • Propane: 8.0 in.w.c.-13.5 in.w.c. 2 in.(51 mm) Ignition System Direct Electronic Ignition nominal PVC/ • Appliance: AC 120 Volts,60Hz. Polypropylene or Electronic Connections . Temperature Controller: DC 12 Volts(Digital)p ( g� ) 3 in./5 in. Water Supply Pressure • Minimum: 50 PSI(Recommended 60-80 PSI for max performance) Concentric. • Maximum: 150 PSI Controller Cable Non-Polarized Two Core Cable(Minimum 22 AWG) °w° • Gas Supply: 3/4 in.(19 mm)NPT • Cold Water Inlet: 3/4 in.(19 mm)NPT Service Connections • Hot Water Outlet: 3/4 in.(19 mm)NPT • Condensate Drain: 1/2 in.(13 mm)NPT • Top: 2 in.(51 mm)* • Back: 0 in. Clearances • Bottom/Ground: 12 in.(305 mm) • Sides:2 in.(51 mm)*** • Front:0 in.** • Vent: 0 in. LF7 * 0 in.from vent components _ 1 1.45 ** Clearance for servicing is 24 in.(610 mm)in front of water heater (290) ***Add 0.25 in.(6.35 mm)for recess box BOTTOM 'Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature. Minimum activation flow is 0.4 GPM(1.5 L/min). Z The maximum gas supply pressure must not exceed the value specified by the manufacturer. eMIN e 0 WATERunir SENSE ITM • C ILD QM Flow curves apply only to incoming water temperatures of 70°F(21°C)or less. For incoming water temperatures greater than 70°F(21*C),please contact Rinnai. B �® 12 11 NOTE:Maximum flow rates may vary based C E Ru1991 i0 on set temperature,Delta T and altitude. D F R U 1801 Connection in. mm s G RU 160i s H RU 130i 6 COLD F 9.54 242 a 5 C 3.56 90 co 4 HOT H 14.27 362 0 9 Dashed lines representfimrate B 6.16 156 2 after parameteradlustment. E 3.57 91 1 ---- -- GAS D 2.78 71 0 o zs so zs too 125 tso LPRV G 10.39 264 DELTAT-TEMPERATURE RISE(°F) A 7.60 193 Rinnai America Corporation°103 International Drive,Peachtree City,GA 30269°1-800-621-9419°rinnai.us ©2018 Rinnai America Corporation.Rinnai America Corporation continually updates materials,and as such,content is subject to change without notice. Local,state,provincial,federal and national fuel gas codes must be adhered to prior to and upon installation. 8/2018 Rui-SP-2 SENSEI' Residential Indoor Spec Sheet