HomeMy WebLinkAboutProject InformationI
Palm
Bruce Bussell
Engineering Manager
Palm Harbor Homes, Inc.
Harbor
605Sou� Frontage Road
PIanECit Florida 33563-9934
Phone: 813-752-1368 Ext.756
Fax 1: 813-754-8675
INS
Fax 813-89
E-Mail: bbussell@ssell@palmharbor.com
March 22, 2017.
To: Building Department
RE: Palm Harbor Home, Serial Number #20737, Model-340TL28532C
Savanna Club, Site 7520
Dear Plans Examiner,
The site -beam, which was installed by Palm Harbor Homes, and is approved by HUD,
Manufactured Home Construction & Safety Standards, is constructed to receive on -site
additions that are built and designed by others to accommodate such amenities as
carports, sheds, and screen rooms. The on -site structure must be designed by a Florida,
registered, engineer, to the Florida Building Code and all local codes. This plant -
installed site beam is of adequate design for this purpose as long as tie downs and piering
are per page 1 of Section 11, Misc. & Final Inspection section of the installation manual
(attached). The attached details, EW-216.2 and PA69-EW-31, are approved by the
Manufactured Home Construction &. Safety Standards. And, the design loads for the
plant -installed site beam, as well as the supporting structure and anchorage are from the
FBC and ASCE 7.
I can be of further assistance at the above contact information.
Sincerely yours,
Bruce Bussell
Engineering Manager
Palm Harbor Homes
I ;.
Option, 1: using 2x4 let4n into dadoed 2x6 wall stud
Metal Flat
Roof Pereei
Secure.Roaf Panel Header
Into.2x4 as approved by
06 manulkwturees
-Installation Iradnictions.
Roor Panel Header----�
Lap Rawlver
Up Siding
caulk
*yp. Tnma
2x4 93 "-F LoWn
Pas tanInto each wall stud
wfth:a as. 0.131W neills,
or 6-as 711 W U20
apples. AIL- 44W30 scrawws
approved sheathing
I.e.- Thennoply. Tbermneaheath
OSS or Plywood:
loin C. Doetien,
P F--
K2 EnginesfK19, irac.
OptionV
2.. using 2x4 installed on top of sheathing
.
and exterior wall studs
Aluminum ftt 8t09*
Typ. Trushaped around 2x4
=---,
and secured Info SOM
and *wwM4ng.Vd MOW
SCreANS.
Socure POW Panel Header
Into 2x4 as approved, by
the manuftckaves
installation Insbu- cdona.
.cad-
Roof Panal--H,eader---�
Lao Recalm
Lap Siding
APPROVED
PFS Corporation
Madison; WI - I
OCT 0 3 2000
HUD Manufactured 11
2x4,#3.S:-P-F
Fast&n into each WaU-$tW
with 4:ea. #6W
approved sheaMl
1.0s Thernx*y, I
088 or Plywood.
Nw- X19.0MA" —> 35
PALM HARBOR HOME
15303 DALLAS PARKWA-Yj- SUITE 800, A
Yrnr-
Screen mom and CarpW attachment
FadM prep options•
S INC.
)DIbON. TX 7.'
1 Imm 09/1