HomeMy WebLinkAboutProduct Approvals (2) { min' mi».
,
'piT=I-- to En tl>RL-j�,UU Hot TDWs subma 5umh3age sb�-a FS +At~TJ+m: cstaR us aCls&[e Nap Un" S_erd,
f"Product APproVal
d=.c
1. usm:Rsblk a..tr
16 ,
RE"I
db
rMx-e rruc-{�1 Fe.•�>N�_4-t•t_�s3,:,a^:^:js^_>S,oucTn�t:.->Mctteuen netaa
CODE C®iill!Ft t FL264W-R6
Revis
COMPLIANCE
-... APpBtaffon Type
Code Version 2020 2020 ion STe LUCIE COUNTY App 6ration Status
Approved aBOCC7(Z44
Comments
Archived
Product Manufacturer APOC,Sub of Gardner-Gibson Inc
Address/PhonelEmail 4161 E.7th Avenue
Tampa,FL 33605
(813)248-2101
akhan@gardner-gibson.com
Authorized Signature Amlr Khan
akhan(agardner-gibson.com
Technical Representative
Addrer'Pb=e1Emaf1
quality Assurance Representative
Addres!4Phone/Emall
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report-Hardcapy Received
Florida Engineer cr Arclutryct Name v.hbo developed the Evaluation Report Ro`x�rt Nieminen
Florida License RE-59166
quality,Assurance Entity UL LLC
Quality Assurance Contract.Expiration Date 12/21/2023
Validated By John W.Knezev(ch,PE
Validation CheckBst-Hardcopy Received
Certificate of Independero-� F7264,2.R6 COI 2020 01 Col NIEMINEN,cdf
Referenced Standard and Year(of Standard) Standard Year
ASTM 01970 2015
ASTM D4533(tear strength) 2915
ASTM D479B(weathering) 2011
ASTM D4B69(liquid transmission) 2016
ASTM D5035(tensile) 2911
FRSA/TRI,Sixth Edition 2018
TAS 103 2020
UL 1897 2915
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 12/17/2020
Date Validated 12/19/2020
Date Pending FBC Approval 12/26/2020
Date Approved 02/09/2021
Model,Number or Name Description
26482.1 .Gardner Roof Undetlaymen[(HVHZ) Roofing undetiayments for use in FBC HVHZ Jurisdictions
1 Limits of Use Installation Instructions
Approued for use in HVHZ-.Yes ,At ER APOC Ft26482-R§jjj-19jR!jf-
Approved for use outside HVHZ:No ;Verified By;Robert Nieminen PE-59166 7
Impact Resistantz N/A Created by Independent Third Party:Yes I
Design Pressure:N/A Evaluation Reports
i Other Refer to Section 5 for Limits of Use. Ft 264R2 R6 AF 2320 12 17 FINAL L!&AFf?C f L75ar3.=5��i'�),tt4l
± Created by Independent Third Party:Yes
h ..__... ----
_ ._ _.... -_. . .. .. ..__ .. .. .. .... -
Gardner Roof Underlayments(NOM-HVHZ) !mogng underlayments for use In FBC nort4MZ JurlsdicNans
Limits of Use ...�. _. ..._._ Installation Instructions
Approved for use in IiVHZ:No FL26482 R6 ii 2020 12 17 FINAL ER APOC R16482�Rf rNOPt-HVH�pdf
.Approved for use outside HVHZ:Yes 7 Verifled By:Robert Niernmen PE-59166
j Impact Reslatant:N/A Created by Independent Third Party:Y s
Design Pressure:+NIA/-135 'Evaluation Reports
other.1.)The design pressure noted herein pertains to particular underlayment system for use ! Fll6482 Rb AE 2020 12�j,FINAL FR APOC FL224r:2�Rb�N�t N-HVriZj�df
< for details.2. Refer to ER Section 'Created b Independent Third Party-,Yes
i e-oof tams.Refer[o ER_action 5.8.3 Y eP
:under adhesive-sett 1 systems. )
5 for Limits of Use. - .
Wmo I etc®
Certificate of Authorization€t32455
353 Christian Street,Unit#13
oxford,CT 06478
(203)262-9245
ENGINEER EVALUATE TEST C011MULT
APOC,sub of Gardner Asphalt Corp. Evaluation Report 1-66-18-001.02.18-R4
4161 E.711 Avenue FL26482-116(NON-HVHZ)
Tampa,FL 33605 Date of Issuance:02/27/2018
(813)248-2101 Revision 4:12/17/2020
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida.The documentation submitted has been reviewed by Robert Nieminen,
P.E.for use of the product under the Florida Building Code. The products described herein have been evaluated for
compliance with the 7th Edition(2020)Florida Building Code sections noted herein.
DEscRipnoN: Gardner®Roof Llnderlayments,for use in FBC non-HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein and FBC 1507.1.1.
CONTINUED COMPLIANCE:This Evaluation Report is valid until such time as the named product(s)changes,the referenced
Quality Assurance or production facility location(s)changes,or Code provisions that relate to the product(s)change.
Acceptance of our Evaluation Reports by the named client constitutes agreement to notify MEMO ETC, LLC of any
changes to the product(s), the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a
complete review of its Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:The Florida Product Approval Number(FL#) preceded by the words "MEMO I etc, Evaluated" may be
displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its
entirety.
INSPECTION: Upon request,a copy of this entire Evaluation Report shall be provided to the user by the mane acturer
or its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
1
Robert J.M.Nieminen PE = 'E-� °' -
� . . �. •„},.;.;; The facsimile seat appearing was authorized 6y Robert
Florida Registration No.59166,Florida DCA ANE1983 Nieminen,P.E,on 12/17/2020. This Goes not serve as
an electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC,LLC does not have,nor does it intend to acquire or will it acquire,a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC,LLC is not owned,operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEW ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any
project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained
specifically for that purpose.
Oc 2019 NEW ETC,LLC
is)
Ea etc.
ROOFING COMPONENT EVALUATION:
r
Product Category: Roofing
Sub-Category: Underlayment
Compliance Statement: Gardnerm Roof Underlayments, as produced by Gardner Asphalt Corp., have
demonstrated compliance with the following sections of the 7th Edition (2020) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations/Conditions of Use set forth herein.
r ^e
Section Property Standard Year
1504.3.1 Wind resistance UL1897 2015
1507.1.1,1507.2.4,1507.2.9.2/R905.1.1, Material standard ASTM D1970 2015
R905.2.8.2
1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tear strength ASTM D4533 2015
R905.1.1.1(2&3,Exception),R905.1.1.1(5)
1507.1.1.1(2&3,Exception),1507.1.1.1(5)/ Tensile strength ASTM D5035 2011
R905.1.1.1(2&3,Exception),R905.1.1.1(5)
1507.1.1.1(5)/R905.1.1.1(5) Liquid water transmission ASTM D4869 2016
1507.3.3/R905.3.3 Material standard FRSA/TRI,Sixth Edition 2018
TAS 110 Accelerated Weathering ASTM D4798 2011
Entity Examination Reference Date
MEMO Traceability FBC Cross-Listing 12/10/2020
PRI(TST5878) ASTM D226(physicals) GGI-176-02-01 9/26/2016
PRI(TST5878) ASTM D1970,D4798 GGI-178-02-01 10/24/2016
PRI(TST5878) ASTM D1970,D4798 GGI-194-02-01 4/19/2017
PRI(TST5878) FRSA/TRI,ASTM D4798,TAS 103 GGI-196-02-01 7/26/2017
PRI(TST5878) ASTM D226,D4533,D4869 GGI-132-02-06 12/11/2017
PRI(TST5878) ASTM D226,D4533,D4869 GGI-199-02-02 12/11/2017
PRI(TST5878) ASTM D1970,D4798 GGI-178-02-01 1/26/2018
PRI(TST5878) ASTM D4798 GGI-178-02-02 1/26/2018
PRI(TST5878) ASTM D1623,TAS 103 GGI-201-02-01 1/26/2018
PRI(TST5878) UL1897 GGI-212-02-01 5/9/201,8
PRI(TST5878) Criticality,ASTM D1876 GGI-209-02-01 5/18/2018
PRI(TST5878) ASTM D903,D1970 GGI-211-02-01 6/6/2018
PRI(TST5878) ASTM D1623,TAS 103 GGI-202-02-01 8/9/2018
PRI(TST5878) UL1997 GGI-243-02-01 5/29/2019
PRI(TST5878) ASTM D1970 397T0016 12/16/2020
PRI(TST5878) ASTM D1623,D4798 397TO018 12/16/2020
UL,LLC.(QUA9625) Quality Assurance Service Confirmation 02/12/2020
UL,LLC.(QUA9625) Quality Assurance Florida BUS Current
9Q a ■
Product Material Standard Plant U Description
4.1 Gardner®Gard-Lock ASTM D1970 Springville, nominal60-mil thick,glass-fiber reinforced,polymer
AL modified asphalt,granulated self-adhering underlayment
4.2 Weather-Armor"FT3 FRSAITRI 09-18 Springville, nominal 60-mil thick,self-adhering membrane of elastic
Tile Underlayment AL polymers,bitumen and polyester and glass
reinforcement
MEMO ETC,LLC Evaluation Report 1-GG-18-001.02.18-R4
Certificate 7n'EDITION(2020)FBC NON-HVHZ EVALUATION FLZ6482-R6(NON-HVHZ)
Gardner°Roof Underlayments,(813)248-2101 Revision 4.12/17/2020
Page 2 of 7
C(N)� NEMOJetc.
- Eirerdu. Material Standard Plant s 17escription
4, Eagle-Armor by Apoc FRSA/TRI 09-18 Springville, nominal 60-mil thick,self-adhering membrane of elastic
AL polymers,bitumen and polyester and glass
reinforcement
4.4 TriBuilt Fleece Tile FRSA/TRI 09-18 Springville, nominal 60-mil thick,self-adhering membrane of elastic
Underlayment AL polymers,bitumen and polyester and glass
reinforcement
4.5 Weather-Armor"HT2 ASTM D1970 Springville, nominal 60-mil thick,self-adhering membrane composed
High Temp Premium AL of elastic polymers,bitumen,glass reinforcement and a
Roof Underlayment cross-laminated sheet surface,gray in color
4.6 Weather-Armor®HT3 ASTM D1970 Springville, nominal 60-mil thick,self-adhering membrane composed
High Temp Premium AL of elastic polymers,bitumen,glass reinforcement and a
Roof Underlayment cross-laminated sheet surface,black/yellow in color
4,7 Weather-Armor®SE-1 ASTM D1970 Springville, nominal 60-mil thick,glass-fiber reinforced.,polymer
Self-BondO Roof AL modified asphalt,granulated self-adhering underlayment
Underlayment
4,g TriBuilt Ice and Water ASTM D1970 Springville, nominal 60-mil thick,glass-fiber reinforced,polymer
Underlayment AL modified asphalt,granulated self-adhering underlayment
4.9 Gator-Skin'Synthetic 1507.1.1.1(2&3, Hangzhou, synthetic roof underlayment comprised of layers of
Roof Underlayment Exception),1507.1.1.1(5) China polyolefin film
/R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
4.10 Gator-Skin 10"' 1507.1.1.1(2&3, Guijarat, synthetic roof underlayment comprised of layers of
Synthetic Roof Exception),1507.1.1.1(S) India polypropylene film
Underlayment /R905.1.1.1(2&3,
Exception),R905.1.1.1(5)
® t comprised of two layers of
4.11 Weather Armor 1507.1.1.1(2&3, Hangzhou, hybrid underlayment co p y
CrossOver CX-L Exception),1507,1.1.1(5) China polyolefin and polyester synthetic fabric with a layer of
Premium Hybrid Roof /R905.1.1.1(2&3, modified bitumen between the two
Underlayment Exception),R905.1.1.1(5)
5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in any way,the Designer
of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami-
Dade Counties).
5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in
accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and
limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations
concerning the use of foam plastic insulation.
5.5 Gardner® Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the Authority Having
Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering.
NEMO ETC,LLC Evaluation Report 1-613-1"01.02.18-R4
Certificate of Authorization#32455 7-EDITION(2020)FSC NON-1°MVHZ EVALUATION F1.26481-116(NON-HVHZ)
Gardner®Roof Underlayments;(813)248-2101 Revision 4:12/17/2020
Page 3 of 7
CN
EMO I etc.
5.6 Allowable Roof Covers:
TABLE 1: ROOF CovER OPTIONS
1507.4& 1507.7 1507.8&2507.9
f8[Sedion: 1507.2 2507 3 1507.5
Clay and Concrete Tile Metal Slate or Wood Shingles
Underlayment Asphalt Mechanical Adhesive- Panels or Slate-Type
Shingles Attach set Shingles Shingles or Shakes
YES
Gardner'Gard-Lock YES NO NO NO YES acint strips,1507.1.1.3
/R905.1.13)
Yes
YES
Weather-Armor'FT3 Tile Underlayment YES YES 07
(see s.6.1) YES YES finint strips,15 .1.1.3
J R905.1.1.3)
-- YES
rEaSle Arm=Apc YES YES Yes YES YES Qnint strips,1507.1.1.3
(See 5.6.1)Yes , /Rx75.1.t3j
YES
TriBuilt Fleece Tile Underlayment YES YES (See 5 6.1) YES YES Qdnt strips,1507.1.13
/11905.1.1.3)
Weather-Armor'HT2 High Temp Premium YES
YES NO NO YES YES Goint strips,1507.1.1.3
Roof Underlayment /R905.1.L3)
Weather-Armor'HT3 High Temp Premium YES
YES NO No YES YES ijulnt strips,1507.113
Roof Underlayment /R905.1.131
YES
TriBuilt High Temp Metal Underlayment YES NO NO YES YES uoint strips,1507.1.1.3
/R905.1.1.3)
Weather-Armor'SB-1 Self-Bond'Roof YES
YES NO NO NO YES Quint strips,1507.1.1.3
Underlayment /R905.1.M)
YES
TriBuilt Ice and Water Underlayment YES NO NO NO YES Qotntstrips,1507.113
/R905.1.1.3)
Gator-Skin"I Synthetic Roof Underlayment YES NO No YES YES NO
Gator-Skin 1011 Synthetic Roof YES NO NO YES YES NO
Underlayment
Weather-Armor'Crossover CX-L Premium YES NO NO YES YES NO
Hybrid Roof Underlayment
5.6.1 Adhesive-set the is limited to use of the following underlayment/tile-adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATION51
Underlayment Adhesive Florida Product Approval
Weather-Armor'FT3 Tile DAP'Touch'n Seal StormBond Roof Tile Adhesive" FL14506
Underlayment,Eagle-Armor by Apoc or Dupont"Tile Bond'"Roof Tile Adhesive" FL22525
TriBuilt Fleece Tile Underlayment ICP Adhesives"Polysetm AH-160" FL6332
'Refer to Tile Manufacturer's orAdhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC,LLC Evaluation Report 1-GG-18-001.02.18-R4
cerdfrrateofAuthodzadon#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION FL26482-RG(NON-HVHZ)
Gardner°Roof Underlayments,(813)248-2101 Revision 4:12/17/2020
Page 4 of 7
EMO etc.
5.7 Allowable Substrates.
TABLE 2: SUBSTRATE OPTIONS
Underlayment Substrates
Gardner"Gard-Lock, Weather-Armor®FT3 Tile Underlayment,Eagle-Armor by Apoc,TriBuilt Fleece Tile
Underlayment,Weather-Armor"H T2 High Temp Premium Roof Underlayment,Weather-Armor HT3 High plywood
Temp Premium Roof Underlayment,TriBuilt High Temp Metal Underlayment,Weather-Armor"SB-1 Self-
Bond"Roof Underlayment,TriBuilt Ice and Water Underlayment
Weather-ArmorO FT3 Tile Underlayment,Eagle-Armor by Apoc,TrIBuilt Fleece Tile Underlayment,Weather-
Armor"HT'High Temp Premium Roof Underlayment,Weather-Armor"HT3 High Temp Premium Roof OSB
Underlayment,TriBuilt High Temp Metal Underlayment
Weather-Armor"FT3 Tile Underlayment,Eagle-Armor by Apoc,TriBuilt Fleece Tile Underlayment,Weather-
Armor°HT2 High Temp Premium Roof Underlayment,Weather-Armor"HT3 High Temp Premium Roof Structural
Underlayment,TriBuilt High Temp Metal Underlayment. "Mote:minimum 737 ambient application concrete*
temperature for structural concrete.
5.8 Attachment Limitations:
5.8.1 For use under mechanically attached NON-TILE prepared roof coverings,attachment shall be in accordance with
the manufacturer's installation instructions,but—for mechanically attached underlayments or base sheets-not
less than FBC 1507.1.1 or R905.1.1.
5.8.2 For use under tile roof systems, attachment shall be in accordance with the manufacturer's installation
instructions,but not less than Section 5.8.3 herein.
5.8.3 Wind Resistance for Underlayment Systems in Tile Roof Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptive in the FRSA/TRl
Florida High Wind Concrete and Clay Roof Tile Installation Manual,Sixth Edition. The Maximum Design Pressure
is the result of testing for wind load resistance based on allowable wind loads,and reflects the ultimate passing
ressure divided h 2(the 2 to 1 margin of safety per FBC 1504.9 has already been applied).
5.8.3.1 Direct-to-Deck:
N =Ch�maxiMU esign pressure for the selected assembly shall meet or exceed that required under FRSA/TRI
Florida High Wind Concrete and Clay Roof Tile Installation Manual, Sixth Edition,Appendix A,Table 1A or the
critical(highest)design pressure determined in accordance with FBC 1609 or FBC Residential Chapter 3.
#1 Maximum Design Pressure=-52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: None
Underlayment: Weather-Armor" FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile
Underlayment,self-adhered.
Maximum Design Pressure=-135.0 psf:
Deck: Min.19/32-inch APA span-rated CDX plywood to meet project requirements to satisfaction of
Authority Having Jurisdiction.
Primer: None.
Underlayment: Weather-Armor® FT3 Tile Underlayment, Eagle-Armor by Apoc or TriBuilt Fleece Tile
Underlayment,self-adhered.
#3 All other direct-deck, adhered underlayment systems beneath tile roof systems carry a Maximum Design
Pressure of-45 psf.
NEML',ETC,LLC Evaluation Report 1-GG-18-00L02.18-R4
Certi}rcateafAuthoriaatlon#32455 7'"EDITION(2020)FBC NON-HVHZ EVALUATION R-25482-116(NON-HVHZ)
Gardner'Roof Underlayments;(813)248-2101 Revision 4:12/17/2020
Page 5 of 7
�
NEMO l etc.
S.9 Exposure Limitations:
TABLE 3: E,xPOSURE LIMITATIONS
Prepared Roof Cover Maximum
Underlayment Installation Type Exposure
(days)
Gator-Skin—Synthetic Roof Underlayment,Gator-Skin lom Synthetic Roof
Underlayment,Weather-Armor"HTZ High Temp Premium Roof Mechanically attached 30
Underlayment or Weather-Armor®CrossOver CX-L Premium Hybrid Roof
Underlayment
Gardner°"Gard-Lock,Weather-Armor®SB-1 Self-Bond®Roof Mechanically attached 90
Underlayment,TriBuilt Ice and Water Underlayment
Weather-Armor"HT3 High Temp Premium Roof Underlayment TriBuilt Mechanically attached 180
High Temp Metal Underlayment
Adhesive-set tile 30
(Polyset"AH-160)
Weather-Armor'FT3 Tile Underlayment,Eagle-Armor by Apoc,TriBuilt Adhesive-set the C
Fleece Tile Underlayment (Tile Bond-Roof Tile Adhesive or 90
Touch n Seal Stormflond Roof Tile
Adhesive)
Mechanically attached 180
5.10 Tile Slippage Limitations: When loading roof tiles on the underlayment in direct-deck tile roof assemblies,the
maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during
loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT-DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging;Method Maximum Slope
Weather-Armor'FT3 Tile Underlayment,Eagle- Flat or Lugged Max.10-tile stack 6:12
Armor by Apoc,TriBuilt Fleece Tile Underlayment
6.1 Gardner® Roof Underlayments shall be installed in accordance with Gardner° Asphalt Corp. published
installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re-fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application,and prime the substrate(if applicable).
6.3 Gardn4o Gard-Lock,Weather-Armor®HT'High Temp Premium Roof Underlayment,Weather-Armoro HT3 High
Temp Premium Roof Underlayment,TriBuilt High Temp Metal Underlayment,Weather-Armor®SB-1 Self-BondO
Roof Urderlayment or TriBuilt Ice and Water Underlayment:
6.3.1 Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached,FBC Approved ASTM D226 Type II felt,the felt shall be fastened in
accordance with FRC 1507.1A or 11905.1.1.
6.3.2 Multi-Ply Underlayment Systems:
Weather-Armor' HT3 High Temp Premium Roof Underlayment or TriBuilt High Temp Metal Underlayment
followed by Weather-ArmorO FT3 Tile Underlayment, Eagle-Armor by Apoc or Tr)Built Fleece Tile Underlayment
(per Section 6.4)is allowable for use under mechanically attached prepared roof systems. Limits of use are those
associated with the top-layer material. This is not a requirement, but is allowable if a multi-ply Underlayment
system is desired.
NEMO ETC,LLC Evaluation Report 1-GG-184101.02.18-R4
Certificate of Authorization#32455 7-EDITION(2020)FBC NON-HVHZ EVALUATION F1.26482-116(NON-HVHZ)
Gardner"Roof Underlayments;(313)248-2101 Revision 4.12/1712020
Page 6 of 7
CSHMO etc.
6.4 Weather'-Armory FT3 Tile Undeelayment,,Eagle-Armor by Apoc or Tri6uiR Fleece Tile Underlaymettt:
6.4.1 Non-Tile Applications:
Shall be installed in compliance with requirements for an approved self-adhering underlayment(ASTM D1970)in
FBC 1507.1.1.1 or 1507.1.1.3 or FBC Residential R905.1.1.1 or R905.1.1.3 for the type of prepared roof covering
to be installed,and the manufacturer's installation instructions.
When installed over a mechanically attached,FBC Approved ASTM D226 Type II felt,the felt shall be fastened in
accordance with FBC 1507.1.1 or R905.1.1.
6.4.2 Tile Applications:
Shall be installed in compliance with requirements for a Self-Adhered Membrane in the FRSA/TRI Florida High
Wind Concrete and Clay Roof rile Installation Manual, Sixth Edition, and the manufacturer's installation
instructions.
Refer to Section 5.8.2 for attachment limitations.
Refer to Table 4 for tile staging limitations.
6.5. Gator-Skin"°Synthetic Roof Underlayment,Gator-Skin 10"4 Synthetic Roof Underigyment or Weather-Armor'&
CrossDvbr CX-L Premium Hybrid Roof Underlayment:
6.5.1 Shall be installed in compliance with requirements for a synthetic underlayment in FBC 1507.1.1.1(2,Exception),
1507.1.1.1(3,Exception)or 1507.1.1.1(5)or FBC Residential R905.1.1.1(2,Exception),R905.1.1.1(3,Exception)
or R905.1.1.1(5) for the type of prepared roof covering to be installed, and the manufacturer's installation
instructions. FBC requirements take precedence over the manufacturer's installation instructions.
6.5.2 Fasteners:
Minimum fasteners shall be corrosion resistant,ring-shank cap nails shall be as set forth in FBC 1507.1.1.1 or FBC
Residential R905.1.1.1.
� s
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
s
Contact the named QA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 QA requirements. Refer
to Section 4 herein for products and production locations having met codified material standards.
UL,LLC.(QUA9625);(414)248-6409;karen.buchmann@ui.corn
-ENO OF EVALUATION REPORT
—
NEMO ETC,LLC Evaluation Report 1-GG48-001.02.18-114
I I
t'z»afxate ojAuthorization!l32455 2020
7T"EDITION F8C NON-HVHZ EVALUATION FL26482-116(NON-HVHZ)
Gardner'Roof Underlayments,(W)248-2101 Revision 4:12/17/2020
Page 7 of 7