Loading...
HomeMy WebLinkAboutProduct Approval � L 77^{E a 41 G I s VC,,eft P Nsc BCTS Home ! Log In User Registration f Hot Topics I Submit Surcharge S Stats&Facts Publications Contact Us BCIS Site Map j Links f Search F#� � ro lFile Copy Product Approval ��-�f'�dr�� USER:Public User �/.J REVI WED FOR Product Approval Menu>Product or Application Search>Application List>Application Detail CODE COMPLIANCE FL# FL27499-R4 1���j � � ��� �® �� Application Type RECEIVED Revision Code Version 2020 �VBOCC-7 Z���1 Application Status Approved ll JUL 2 7 2021 Comments St.Lucie GountN Archived Petri111lIQ Product Manufacturer Dynamic Metals Address/Phone/Email 3201 SE Dominica Terace Stuart, FL 34997 (772)872-8030 juan@dynamicmetal.net Authorized Signature Lara Jesus juan@dynamicmetal.net Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Scott Wolters Evaluation Report Florida License PE-62354 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 12/06/2026 Validated By Lucas A.Turner,P.E.,MBA 0" Validation Checklist-Hardcopy Received Certificate of Independence FL27499 R4 COI Dyn COI.odf Referenced Standard and Year(of Standard) Standard Year TAS 100 1995 TAS 110 2000 TAS 125 2003 Equivalence of Product Standards Certified By Sections from the Code _ 1 WOLTERS ENGINEERING ENGINEERING,DRAFTING,CONSULTING 1521197+h Road N Wesf Palm Beach,FL 33412 Ph/Fx:(561)225-19.82 PRODUCT EVALUATION' (FOR.HVHZ APPROVED PRODUCT) PRODUCT: DM CLASS 1000.26 GA. GALVALUME 1 NAILSTRIP 16 WIDE ROOF PANEL(FLPA#27499.1) MANUFACTURER: DYNAMIC METALS., LLC 3201 SE.DOMINICATERRACE STUART, FL 34997 To all concerned, The DM Class 1000.Series 26 Ga. Galvalume 1'' Nailstrip 16"Wide Roof Panel, manufactured by Dynamic Metals LLC,'is a non-structural galvalume coated Fluropon painted steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4 and 1518.9 of the 7t Edition (2020) Florida Building:Code. The panel has been tested per TAS'100, TAS 125;and ASTM E2140 by Intertek B&C with results shown.in test reports G3443.40-450= 44,G3443.14-450-44, and M 1607.01-450-44. It has also,been tested.per-TAS 110 by PRI Construction Materials Technologies,with results shown in test reports VLS-004-02-01 and VLS-005702-01. Technical Documentation:. 1. Drawing "NSS16-HZ"dated 8/16/1.9, signed and sealed by Scott Wolters, PE. .2. Test Reports listed above by Architectural Testing, Inc.signed and sealed by Vinu Abraham, PE, and by PRl Construction Materials Technologies, signed and sealed by Zachary R Priest, PE'. 3. Supplemental Calculations to support NSS16-HZ, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the,requirements of FAC Product Approval.Rule Chapter 61020=3.005 (4). Based on the limitations listed below and those provided in the documents above,this.product meets all the requirements of the 7t Edition (2020) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions. Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 16" (nominal) Fastener Spacing across panel: 16" (at Nailstrip) (Panels overlap with male/female snap fit) Min.Slope: HVHZ: 1"/12" Non-HVHZ: Y2712" SPECIALIZING IN IMPACT'P�515fMf CUFUAINWAU5, 5fOt?W� f5, & WINPOW5 i � ® m M I Z I W 1 m o 0 , Cl O n rD Lu I, En ty O O to Ilf N cp 3 X Q N S @ 2 -- ` m;�z - - $ m cp Lo a cnXm o r w v a a 0 1 O m i II DYNAMIC METALS SLa„B 2354 LMIS �W�A � L FL PE 6ZJ '� W � •• nt7LiER5 EfidtiEIIi1�:L "Ct: '•k — _ tp 3201 SE DOMINICA TERRACE ,wtAv.dynamicmetal.ner (Copp Z7tg4) MANE cltau�E s/t5 is u2n 9M ROAD W STATE OF u _ r I STUART,Ft 34997 FAX:(772)247-2466 V ST PALM t EAOL fL S1af Y�O \ PH: 77_)247-2465 EMAIL:info@.dy (Set)zn +asz �i�)LI �i(� t57 SUBNiTtAL t,,, ( namrcme[al.net %C`SR .�F i .• 9` PRL14TS ISSUED FCR REY.a DATE Zw 4. All panel system perimeters, penetrations, and transitions to be flashed and sealed per the requirements of RAS 133. 5. Rational analysis, provided by a Florida licensed Architect/Engineer per FAS 61G20.3.005(e), may be used for project specific approval by the local authorities having jurisdiction. 6. Where required by the Florida Building Code, panels shall be permanently labeled with the manufacturer's name and/or logo, and the following statement, "Dynamic Metals FL#27499.1, DM Class 1000". Panel Forming: These panels may be jobsite roll formed with the following Dynamic Metals machines, per approval of 3m party QA provider,to the dimensions shown on Drawing NSS16-HZ: SSQ-6800617 SSQ-5150216 SSQ-6810617 SSQ-6690517 SSQ4560615 SSQ2-2310920 5VC-0490718 5VC-0360516 SSQ2-2320920 Re-Roofing: The DM Class 1000 Series 26 Ga. Galvalume 1"Nailstrip 16"Wide Roof Panel may be installed over a single layer of existing asphalt shingles, provide the existing roof meets the requirements of Section 1511 of the Florida Building Code. If you have any questions or need more information concerning this approval, please contact me. Thank you, r• °���' ,'�uti'°`r ``�"�••CEN��f`xs '� No 62354 .� Scott Wolters FL PE#623540 .APR 15 20���•'= STATE OF •:�/ 5F�CKIZING IN IMFAC1"Q:,�51%Mf CUMINWAL1,5, %Rf-FP.DN1W5, &WIN aV5 Option#1 Option#2 Installation Installation Max. Design Pressure: -116 psf -176 psf Fastener Spacing: 3" From Ends, 6" Max. O.C. 3" From Ends, 6"Max. O.C. Min Panel Fasteners: #10x1" Panclip Fasteners #10x1" Panclip Fasteners Panel Sealant: Continuous bead of Geocell 2300 ontinuous bead of Geocel 2300 or 2320 at Nailstrip side of seam r 2320 at Nailstrip side of sea at roof slopes<3 712"only) Fire Barrier: Where required by code, install an approved fire barrier. Refer to a current fire directory listing for fire ratings of this roofing system assembly as well as the location of the fire barrier within the assembly. (See note#2 below) Note: Outside of the HVHZ in areas with windspeeds< 170 mph, 1" round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Underlayment: Minimum ASTM D 226 Type ll, installed and anchored per FBC Section 1507.1.1.1 (min). (or) Any underlayment with a valid FLPA or Miami-Dade NOA Note: Outside of the HVHZ in areas with windspeeds < 170 mph, 1"round plastic caps meeting the requirements of FBC Section 1507.1.1.1, may be used to prevent galvanic reactions. Minimum Substrate: '/2' (15/32" min)4-ply CDX Plywood or 3/4"solid wood planks (S.G. = .42 min) nailed to 2x rafters spaced 24" max.on center with 8d ring-shank nails spaced 6"on center. Note: The 1/"wood planking must be installed as a solid deck and must be nailed or fastened in a manner equal to the deck above, or as specified by a Florida licensed Architect/Engineer Other Limitations: 1. Roof slope must meet requirements of FBC Sections 1507.4.2 or 1515.2. ` 2. Fire classification is not a part of this evaluation. Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 3. Design of substrate is by others and is not a part of this evaluation. 5P CKIZING IN IMPACT r?E515fMf CUKAINWALI,5, 5f0l�FF;ON1"5, & WINPOW5