Loading...
HomeMy WebLinkAbout5380 - Architectural Store RevisionPart-2 07/26/2021 4'-11" 51/2" 4'-0" 51/2" 3 2„ 1'-9„ 2„ 1' g„ 2" a N o U en o o .y TOWER PEAK 'b a � � V � 33'-4" No(� RF2 to T.O.SHUTTERS cd O N O O 3 ��� ��� 13 -6 r ' A6.2 �_ 1 PBS N V1,c A-I fiI w � I I OVH2 I ^ I G1 G1 I I EXTENT OF ALUM. TOWER BRIG. - I I 26'-10" "It I I CLOSURE DS2 PAR I I PANEL/FLANGE -J EQ 2 10„ DS2 LAPPED BEHIND TRIM a 2 -10 EQ PVCT I I co FCST FCST I I � I I y T.O.PARAPET I I B.O.SHUTTERS u 22'-4" PVCT � S 0 OFS PVCT W T-11' 3'-4" '13'-4112" �3' 31/2" G1 RF2 3' 43/4". .' 98' 11 1l2 OFS / v LINE OF TOP OF ROOF DS OFS LADD - - - - V/ D S _ _ r..a 0000 0000 0 00 \N 3'-7" r 4'_11"- 3,-0 JST.BRIG.REAR - 5 U 2'-9� _. EQ SIGN EQ. 2, g f STU1` - - 16'-4 3/4" �--' RSUP - DS DS2 A4.1 MTPN „ „ TYP 3'-91/2" DS2 29'-5 3/4" 8 3114- 15 11 3/4 3 10 SCJ OVH STN2 LIGHT LIGHT a a 11 " " 1 1, 1 - 1/1 / LIGHT LIGHT SECURITY CAMERAS FCST LOUVER. RE: RE: ELECTRICAL FCS SCJ MECH. DWG'S. SCJ I -_ T.O. MULLION&SILL PAINT LOUVER EP6_ PBS PBS T-0" TO MATCH STUCCO - PVCT STU2 PVCT (--� STN1 1 LIGHT LIGHT o FCST o SOFF sTu1 sTu1 EQ EQ 3 BAHAMA SHUTTER DETAIL wfpEQ EQ "-0- ' co - ICE A4.1 112"=1'-0„ MTPN MTPN MTPN CEMENT BOARD LAP SIDING 00 ' T.O. MULLION&SILL OVER ONE LAYER HIGH `� `� 3'-0" DENSITY POLYETHYLENE _, j M BARRIER OVER ONE LAYER � c9 _SF BUTYL RUBBER MEMBRANE BARRIER OVER 5/8"EXTERIOR T.O.FLOOR SLAB GRADE PLYWOOD SHEATHING Q STN2 14B 8 FCST EXTEND DOOR TRIM STN2 BOLLARDS 0 0 STARTER STRIP Q A4.0 4 TO FINISH FLOOR,TYP DUPLEX STN1 '47'0 YP ALL OUTLET A4.1 BEHIND DS 14A RECPT STN1 J @ STONE VENEER DOWNSPOUT WITHIN A7,0 >- TOWER LEG FRAMING WALL BEHIND LAP SIDING J U) GENERATOR BOX. 1 REAR ELEVATION RE:DETAIL 17/A7.0 FOR 1/2"CPVC TRIM m Z LU INSTALLATION. RE: ELECTRICAL NOTE: ALL SIGNAGE WILL BE w Q ~ 0_ A4.1 114"=1'-0" FOR DIMENSIONS AND LOCATIONS. 1"CPVC TRIM a W PERMITTED SEPARATELY. �, z Q 1x2 CPVC TRIM � w O Q N co CONT. FLASHING ALUMINUM SHUTTERS. 4'-11" RE: ELEVATIONS PRE-FINISHED 18-GA.WHITE 53/8" 4, 0„ 55/8" ALUMINUM CLOSURE PANEL BEHIND SHUTTERS RF3 TOWER PEAK 2" 1' 9" 2" 1'-9" 2" 33'-4" - WATER-RESISTIVE -I' BARRIER 4 RF2 A6.2 _ __` T.O.SHUTTERS 8"METAL STUDS(TYP) ALUMINUM SHUTTERS OVH2 1 RE:ELEVATIONS 0 cfl I I O SCJ G1 I I PRE-FINISHED 18GA. 2 WHITE ALUMINUM O 3 4 G1 i I PBS CLOSURE PANEL BEHIND _ 3 SHUTTERS 12'-91/2" A6.1 3'-1 1/4", EQ EQ 2.-6 3/4" I I WATER DS2 STU1 - _ BARRIER F T M I I ' �- LADD SAFETY CHAIN FCST PAR I I (2)16-GA STUDS AND(2)16- T.O. PARAPET " I I GA)TRACKS TOP&BOTTOM. o I I EXTENT OF ALUM. STU1 22' 4" I SIGN M I I CLOSURE GWB RE: PANEL/FLANGE T � PLAN PVCT F RE RESISTANT EXTERIOR YWOOD GRADE I I TRIM LC� I I LAPPED BEHIND WALL TYPE FOR ¢ co SCJ LINE OF TOP OF SHEATHING AT ENTIRE SURFACE ---- ROOF BEYOND - _ -- -- - --- -- - B.O.SHUTTERS a LLI --23'-10'-------------------- --.---- --- „ -- ---- -- CONT FLASHING CONT ---- 22 -5 v 11' 11' r / / i EQ `�' 7-2" PERIMETER BEHIND SIGN. i ------ i � / i i SEALANT � LL DS2 SIGN,BY SIGN CONTRACTOR. CONT.SEALANT,TOP AND O 0 '-61/8" 9' 0 7/8" PROVIDE BLOCKING PER MTPN SIDES O N U) FCST SIGNAGE MFR'S REQUIREMENTS. 11'-11" SECURITY CAMERAS TYP ROLLER Z SEE DETAIL 3/A5.0: RE: ELECTRICAL PVCT o PROVIDE END DAMS SHADE. RE: O SIGN LIGHT SCJ . , _ STU1 @ SILL(TYP.) ELEVATIONS r STU1 STU1 CONT.SILL"Z"FLASHING. CN z O 0 FCS - FCST 0 �_ LIGHT DO NOT SEALANT 11 3 . 11 -2 . , BETWEEN SILL AND CONT. FLA - SEASANT SEALA NT m PVCT PERIMETER � w T.O.MULLION&SILL C7 J PBS 3 -0 BENEATH L-L� MTPN2 LGD MTPN2 o PVCT �� FCS00 FLASHING ONLY ;u LIGHT o TG o TG STN2 FCST FCST (1) 16-GA STUD AND DS1 EP1 EP1 / o LIGHT 5 STN1 (2)16GA)TRACK. ULu a Q w rJ � #1 N 8"METAL STUDS(TYP) � w CO2 0 STN1 -,o o MTPN MTPN STN1 A4.0 METAL PANEL. INSTALL PER v Q 'i / MFR. RECOMMENDATIONS. 2 z FL w Z J STN2 D1 5, „ 4' 11" 3' 2" 4' 11" 5' 5" STN2 ELEVATIONS = ~ CO 11 RE: E rJ T.O. MULLION&SILL o O u- w W 3� 4 BAHAMA SHUTTER DETAIL 5 EXTERIOR WINDOW SECTION N STN1 o \ 0 STN1 A4.1 1/2"=1'-0" A4.1 3"=V-0" o o N i I \ N T.O.FLOOR SLAB b OF•Fop STN2 GENERAL NOTES Digitally signed byR SDa _ WALL HYDRANT 3 a G r 6"X 6"ACCESS PANEL EXTEND DOOR TRIM DUPLEX RECTP VINYL FENCE BOLLARD(TYP.) gERT&=c�N belS 01 A4.1 oDooaoats o z s, FOR TEMPORARY TO FINISH FLOOR,TYP FOR ICE - STORE NUMBER SIGN 2"HIGH STN1 o=c AND PETE I c SPECIAL 1. ALL BLOCKING @ HARDIE FOR LIGHTS,SECURITY ITEMS.SEE DETAIL 18/A7. y L _ ENGINEERSPLANI�E S WATER HOOKUP. 7 MERCHANDISER. NUMBERS,COLOR BLACK. 8 PURPOSE 2. MOUNT SECURITY CAMERAS THE SAME HEIGHT AS THE EXTERIOR WALL FIXTURE • ContactlnfoaThisdocu ntts° n ALIGN WITH VISION GLASS !S ���/electronically signed 40 tyto art A4.1 CO2 WARNING A4.0 RECEPTACLE 3. PROVIDE 6"X 8"ELECTRICAL BOX STONE TRIM BY BOULDER CREEK, COLOR ANTIQUE TAN AT °d Day usfliga Digital rio�gd pi SIGNAGE TYP ALL OUTLET L of his comment are t nrri e ALL EXTERIOR ELECTRICAL RECEPTACLES MOUNTED ON STONE. SEE DETAIL 8/A4. C and sealed and the s reim ube ri d 2 LEFT ELEVATION @STONE VENEER 4. PETERSEN PAC-CLAD IS AN ACCEPTABLE ALTERNATE MFR. FOR PRODUCTS WHERE"ATAS"IS a Date 2 2;00.261 04'Bo• A4.1 114"=1'-0" SPECIFIED. PROVIDE EQUAL OR BETTER QUALITY PRODUCTS.SUBMIT PRODUCT DATA TO � _ ARCHITECT FOR APPROVAL. a 07/21/2021 A CO2 FILL PORT ARCHITECTURAL - EXTERIOR FINISH SCHEDULE ARCHITECTURAL - EXTERIOR FINISH SCHEDULE N N N N N C" +�+ N IN N N N SYMBOL MATERIAL MANUFACTURER COLOR NOTES SYMBOL MATERIAL MANUFACTURER COLOR NOTES m ► co - M N N O N CO2 CO2 FILL BOX WITH PVC SLEEVE THRU WALL SUPPLIER LO ATION AND MOUNTING DETAIL RE: PAR ALUMINUM PARAPET CAP ATAS INTERNATIONAL INC. COLOR TO MATCH ADJACENT TRIM ALTERNATE:PETERSEN PAC CLAD It (o (o i ti ti O O O O O DETAIL 7/A4.1 A PBS PREFINISHED ALUMINUM BAHAMA SHUTTER FENWALL FABRICATION& COLOR TO MATCH ADJACENT TRIM SHUTTER PER SPECS. CONTACT: KERRI BEALS DS ALUMINUM THRUWALL SCUPPER& ATAS INTERNATIONAL INC. POLISHED ALUMINUM W/CLEAR ANODIZED FINISH D A WITH CIVIL FOR CONNECTION TO STORM MFG. 813.343.5979, COLLECTOR AND 4"DIA.ALUMINUM SEWER. SEE DETAIL 14A&14B/A7.0.ALTERNATE: ALTERNATE: SUPERIOR CUSTOM SHUTTERS,CONTACT: o DOWNSPOUT PETERSEN PAC CLAD DAVID DANIELS 407.949.1969 T.O.MULLION&SILL � V) c O 3'-0" DS1 4"DIA.ALUMINUM DOWNSPOUT. REFER TO ATAS INTERNATIONAL INC. POLISHED ALUMINUM W/CLEAR ANODIZED FINISH COORDINATE WITH CIVIL FOR CONNECTION TO STORM PVCT ACCENT TRIM AZEK WHITE, FINISH:SMOOTH;SEE DRAWINGS FOR DIMENSIONS PRE-FINISHED, ALTERNATE:PALIGHT o }' Ln SPECS FOR GAUGE SEWER.SEE DETAIL 14A&14B/A7.0.ALTERNATE: RF2 METAL ROOFING ATAS INTERNATIONAL INC. MRD194 DUTCH SEAM,(1 1/2")19.25",COLOR:#23 COPPERTONE ALTERNATE:PETERSEN PAC CLAD m y w w w PETERSEN PAC CLAD RF3 STANDING SEAM ROOF HIP CAP ATAS INTERNATIONAL INC. TO MATCH METAL ROOFING ALTERNATE:PETERSEN PAC CLAD = m L W w DS2 4"DIA.ALUMINUM DOWNSPOUT ATAS INTERNATIONAL INC. POLISHED ALUMINUM W/CLEAR ANODIZED FINISH ALTERNATE:PETERSEN PAC CLAD ~ w ~ 0 6X6 ACCESS PANEL RSUP ROD SUPPORT&PLATE POWDER COAT,MATCH SW#6076 SEE STRUCTURAL.ALL RODS NOT INDICATED ON g N m � EP1 PAINT BENJAMIN MOORE COLOR:WHITE DIAMOND 2121-60 FINISH:EGGSHELL DOOR&FRAME STRUCTURAL ARE PURELY DECORATIVE RE:21/A3.1 w w Lu u w FOR TEMPORARY 1 4 EP6 PAINT BENJAMIN MOORE COLOR:WESTMINSTER GOLD#200, FINISH:SEMI-GLOSS SCJ STUCCO CONTROL JOINT-3/4"WIDE 'W SHAPED ACCORDION STYLE RE:SPECS 0- Of a 00 0- WATER HOOKUP. EMERGENCY CL FCS ARTISAN FIBER CEMENT LAP SIDING JAMES HARDIE COLOR:HARRIS CREAM, FINISH:SMOOTH,8.25"X 12' PRE-FINSHED.PROVIDE COLOR-MATCHED CAULK BY SIGN ILLUMINATED SIGNAGE SIGN BY WAWA,SURFACE MOUNTED;PERMITTED c 3'-5" OVERFLOW JAMES HARDIE � Z SEPERATELY Q PROVIDE SCUPPER FCST ARTISAN FIBER CEMENT ACCENT TRIM JAMES HARDIE COLOR:ARCTIC WHITE,FINISH:SMOOTH, 1.5"TH x 6"W x 10'-0"L PRE-FINSHED.PROVIDE COLOR-MATCHED CAULK BY SOFF MPS120,SOLID AND VENTED ATAS INTERNATIONAL INC. BONE WHITE BUILDING OVERHANGS.ALTERNATE:PETERSEN PAC-CLAD WITH SLOTS JAMES HARDIE SPAN SPANDREL GLASS, 1"INSULATED TEMPERED VERICON SUBDUED BRONZE FRIT TO BE ON INSIDE OF PANEL a `" G1 ALUMINUM GUTTERS POLISHED ALUMINUM W/CLEAR ANODIZED FINISH CONTINUOUS-NO SEAMS ALLOWED.SEE SHEET A3.1 STN1 MANUFACTURED STONE VENEER BORAL SOUTHWEST BLEND PF 8019,PRO-FIT LEDGESTONE ICE ICE MERCHANDISER LEER PAINT BENJAMIN MOORE,BM OC-1 NATURAL WICKER „ = s a COLLECTOR BOX co STN2 PRE-CAST MANUFACTURED STONE BORAL TAUPE CSV-1375 VERTICAL GROUT JOINTS:3/16 MAX.WIDTH.GROUT WITH ¢m p o 0 _ T.O.FLOOR SLAB co LADD METAL EXTERIOR LADDER EASTERN METAL SUPPLY BRUSHED ALUMINUM E SHE T!Z.1 OR D T LS A WATERTABLEISILL BONSAL#71 WARM IVORY Z rn N p 0'-0° LGD 6'LADDER GUARD#LG6 VISIONMASTERS EQUIP. FINISH:MILL STN6 PRE-CAST STONE CAP ITALIAN CAST STONE COLOR:WHITE SEE SHEET A10.GROUT JOINTS 3/16"MAX.WIDTH.COLOR: }o Lu CD w 3 a v ¢ N N CO. WHITE(TO MATCH STONE CAP) ao m o c�I 1 o ¢ w c9 N 2 -- ------- ---- 1'-4" LIGHT EXTERIOR LIGHT FIXTURE SEE ELECTRICAL DRAWINGS AND DETAIL 18/A7.0 FOR STOR STOREFRONT SYSTEM KAWNEER CLEAR ANODIZED SEE SPECIFICATIONS U a 0 A7.0 , MOUNTING STU1 STUCCO SENERGY #3085 MERINGUE,FINISH:SAHARA ROOF SURFACE MTPN METAL PANEL q FENWALL FABRICATION& OLOR TO MATCH ADJACENT TRIM BAHAMA SHUTTERS ASSEMBLY.CONTACT(407)408-3932. STU2 STUCCO SENERGY #308 STARK WHITE, FINISH:FINE MFG. RE:DETAIL 5/A4.0 TG 1"INSULATED TEMPERED GLASS SEE SPECIFICATIONS A4 . 1 MTPN2 METAL PANEL FENWALL FABRICATION& AINT TO MATCH DOORS, EP1 PANEL ABOVE DOOR.CONTACT(407)408-3932; RE: DETAIL TGT 1"INSULATED TEMPERED GLASS VITRO ARCHITECTURE GRAYLITE II. SEE SPECS SEE SPECIFICATIONS FG. 6/A4.0 7 CO2 AND WATER HOOKUP DETAIL g SCUPPER AND OVERFLOW DETAIL OFS ALUMINUM 8"X 16"OVERFLOW SCUPPER ATAS INTERNATIONAL INC. POLISHED ALUMINUM W/CLEAR ANODIZED FINISH ALTERNATE:PETERSON PAC CLAD OVH METAL OVERHANG FACING ATAS INTERNATIONAL INC. RAPID-LOK FASCIA&RAPID-LOK COPING,COLOR:#17 BRITE RED SEE A3.1 FOR DETAILS.ALTERNATE:PETERSON PAC CLAD A4.1 314"=1'-0" A4.1 V.=1'-0" OVH2 HIP ROOF FASCIA ATAS INTERNATIONAL INC. BRAKE METAL,COLOR#26 BONE WHITE SEE A3.1 FOR DETAILS.ALTERNATE:PETERSON PAC CLAD A 07/26/2021 1 3� A6.0 NOTE: ALL EXTERIOR N a o TOWER PEAK � 33'-4" - - - - - - - - - - - - WALLS TO HAVE R-30 N o U cn o o O INSULATION w � 1 (8 MN RF2 iz� o 1 A6.2 DS2 2' 10" EQ. EQ - _ 2'-10"` DS2 BACK OF PARAPET BEYOND - - ; • SCJ T.O. PARAPET // - WALL HYDRANT T.o. PAR�PE� v� a • AP5 4 ROOF DECK&INSULATION co (V t4 JST. BRG. MID FRONT W I I v � I I I Tn�,�x®od SUSPENDED ACOUSTICAL TILE CEILING 6 ' COFFEE p O RETAIL ARE III I SELF SERVICE I I WALK-IN REFRIG. I I I I T.O. FLOOR SLAB M 0'-0" W O O . O � �_ - W Z � Q BUILDING SECTION A5.0 - � J 114"-1'-0" U) J Q Z 00 Z Q W LU CL z W Q w Q p 0 � N � 2 — — — T.O.PARAPET A6.1 22'-4" LIGHT FIXTURE RE: ELECTRICAL I I SLOPE: 114"/ 12" JST. BRG. FRONT 17--101, SUSPENDED ACOUSTICAL N TILE CEILING° JST. BRIG. REAR 16'-4 3/4" o 0 RETAIL WALK-IN '� RETAIL WALK-IN 3 BEER COOLER REFRIGERATOR r 3 � BEERCOOLERD � D DD o a BEER r _ o ' O� - I o 0 00 M RETAIL AREA \ RETAIL WALK-IN EFRIG. m W i i m 00 T.O. FLOOR SLAB a a a, Or or, o T CD CN42 O O = I-- U CN 8 m z W Cn '2� BUILDING SECTION N OO J QILL w z 0 wQW0f 0 0 W w J LAP SIDING PER FINISH Z Q J — SCHEDULE „ o � 0 I w m CO ONE LAYER HIGH-DENSITY a POLYETHYLENE BARRIER N OVER ONE LAYER BUTYL RUBBER MEMBRANE 5/8"PLYWOOD FLOA 5/8"FRT PLYWOOD BEHIND RIGID INSULATION(TYP7t4 .) a 4 Digitally signed by R SDay C==SIGNAGE RE:ROOF PLAN, SHEET �, CN=Robert 00 1 6' 7/8"STUCCO FINISH OVER 3.4#SELF c� ZpgERT0 yp� ANDPol8 7� go 2 s, 8"METAL STUDS A3.0 o=c ANDPETE hta C ti ENGINEERS PLANNE S FURRING GALVANIZED METAL LATH p,;,.� Reason:I have reviewe icn. GOOSE LOGO SIGN 8"METAL STUDS @ 16"O.C. FRb S Flay Contact Into This dono nt as tLen OVER ONE LAYER HIGH DENSITY `z�R electronically signed s 0I<Ro art Day usfig a Digital S n d pi 1/2"LIQUID TIGHT STEEL TUBE. RE:STRUCTURAL METAL DECK. POLYETHYLENE BARRIER OVER ONE L of this document are t n rJs and sealed and the s uraMu9t a art d T Date 2 21.07.2615:I 31-04'B0' CONNECTOR — — RE:STRUCTURAL R30 BATT INSULATION _ LAYER BUTYL RUBBER MEMBRANE 0 ANCHOR PER MFR. SPRAY ALL VOIDS GWB TO UNDERSIDE OF BARRIER OVER 5/8"EXTERIOR GRADE PLYWOOD SHEATHING 5/8"EXTERIOR GRADE PLYWOOD WITH FOAM SEALANT DECK(TYP.)ALL EXT. RE: EXTERIOR ELEVATIONS a .r 1/4"-20 ANCHOR BOLT TO WALLS 07/21/2021 SPACER SLEEVE AT EACH BE DETERMINED BY WALL ° STEEL BEAM. AZEK TRIM(BEYOND) ANCHOR,AS SHOWN ° TYPE RE:STRUCTURAL ` RE: EXTERIOR ELEVATIONS N N IN N N N 7/8"STUCCO FINISH OVER 3.4# 1/2"GWB 20 O O O O O GWB TO UNDERSIDE A3.2 M N N N N N 2"X 2"X 1/8"STEEL ANGLE, SELF FURRING GALVANIZED METAL G i CO CO o0 N N O N TYP LATH OVER ONE LAYER HIGH OF DECK(TYP.)ALL TUBE STEEL BEAM N It o o r- r- LISTED DISCONNECT DENSITY POLYETHYLENE BARRIER VESTIBULE WALLS I I o 0 0 0 0 "WAWA"LOGO SIGN — OVER ONE LAYER BUTYL RUBBER RE:STRUCTURAL 3 a� SWITCH r INSULATE MEMBRANE BARRIER OVER 5/8 EXTEND ROOFING MEMBRANE UP � DOWNLIGHT. VOIDS AT BEAM 8"METAL STUDS @ 16"O.C. D TRANSFORMER BOX EXTERIOR GRADE PLYWOOD WALL MIN.8"VERT. Im RE: ELECTRICAL SHEATHING.RE: EXTERIOR y c O LED POWER SUPPLY ELEVATIONS 8"METAL STUDS R30 BATT INSULATION _ 6"METAL FRAMING c 2 o _ � 1/2"LIQUID TIGHT 1/2"LISTED FLEX(LIQUID @ 16"O.C.,TYP (TYP.) y ` ~ > RE:STRUCTURAL 5/8"PLYWOOD SHEATHING LU TAPERED INSULATION BOARD o uwi ❑ oN o H H CONNECTOR TIGHT SHOWN) � 8"METAL STUDS @ 16"O.C. — METAL DECK = N m g ANCHOR PER MFR. TO PRIMARY SOURCE - w w w ❑ w HEADER RE:STRUCTURAL � > w � 1-1/2"18 GA FURRING RE:STRUCTURAL LIGHT GAUGE METAL FRAMING o m a 1/4"20 ANCHOR BOLT TO WRAP ONE LAYER HIGH DENSITY R30 BATT c SPACER SLEEVE AT EACH BE DETERMINED BY WALL POLYETHYLENE BARRIER AND ONE INSULATION RE:STRUCTURAL o 0TTFFIJ ANCHOR,AS SHOWN TYPE LAYER BUTYL RUBBER MEMBRANE STOREFRONT B.O.OVERHANG Z Q BARRIER UNDER BOTTOM OF SOFFIT Sim. 9,-0„ 2"X 2"X 1/8"STEEL ANGLE, SOFF AND INTO STOREFRONT ROUGH 9 a SPACER CUT ANGLE SHALL MATCH TYP ' 12"WIDE SOFFIT PANELS OPENING I — A3.2 1 1/2" 18 GA FURRING @ 12"O.C. - LAP SIDING SLOPE. PROVIDE SOFFIT o LISTED DISCONNECT +/_2r_2" �s a LIQUID TIGHT MASTIC,TYP — SWITCH EQ EQ CENTER DOWNLIGHT WRAP ONE LAYER HIGH DENSITY RE: EXTERIOR ELEVATION SCHEDULE a m o 0 ON SOFFIT PANELS — — — 8"-16 GA METAL POLYETHYLENE BARRIER AND ONE UNVENTED SOFFIT THIS A EA o Z � CD N TRANSFORMER BOX T.O.CLERESTORY - STUDS @ 24"O.C. LAYER BUTYL RUBBER MEMBRANE LIGHT FIXTURE }o '� CD w R a v Q N LED POWER SUPPLY 6 - _ - _ _ = - - ; '= BARRIER UNDER BOTTOM OF SOFFIT RE: ELECTRICAL g o �, o a Q w c� N NOTE:TRANSFORMER BOXES TO BE LOCATED `__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___ = 5/8"M.R.GWB CEILING AND INTO STOREFRONT ROUGH a o o U ABOVE CEILING AND BELOW ROOF DECK. NO 1/2 LISTED FLEX(LIQUID OPENING CONT. P.T.WOOD BUCKS SHALL BE ROOF OR PARAPET PENETRATIONS ALLOWED. TIGHT SHOWN) -___ ATTACHED USING HILTI KWIK-PRO STOREFRONT SELF DRILLING SCREWS S-WW TO PRIMARY SOURCE 14X20X2-3/4"PFH#4 WINGS @ 18"Q.C. A5 . 0 3 SIGNAGE DETAIL LAP SIDING IF REQ'D) 4 PORCH/ENTRY SOFFIT 5 " SOFFIT DETAIL FRONT ENTRY �60, SOFFIT DETAIL SIDE ENTRY _ A5.0 1rr=1'-0" A5.0� 1"=1'-Orr A5.0 1"=1'-0" A5.0 1 112"=1'-01, , 07/26/2021 STORFRONT LEGEND e 9'-3" 9'-3" 8 91/2 TEMPERED GLASS P-+ N N n n 4'-1 3/4" 2" 4'-1 3/4" 2' y o 4'-4" 2" 4'-5' 2 4'-41/2 2' 4'-4 1/2 2 OR Or OR OR Or 00CV N N U cn o o .oy M SPANDRAL GLASS N 9 o t\ r- o� o TG TG TG TGT TGT TGT TGT TGT TGT .�. . o _ = N V1� Q•I W � w " 4'-6 1/4" 2" 6'-01/2" 2" 4'-6 1/4" 2' METAL TRANSOM SF STOREFRONT ELEVATION SF STOREFRONT ELEVATION SF STOREFRONT ELEVATION SFg STOREFRONT ELEVATION � � A5.1 112"=1'-0" A5.1 112"=1'-0" A5.1 112"=1'-0" a cd 15'-91, 11'-03/8" 9'-3" 9'_3" 8'-91/2" 4 61/2 2" 6 0 2 4 61/2 2 2'-2" 2" 6'-0" 2" 2'-2 3/8" 2' 2 /8" 4'-5 3/4" 2" 4'-2 7/8" 2' 4'-41/2" 2" 4'-41/2" 2' 4'-1 3/4" 2" 4'-1 3/4" 2' ,0 N CV N N N CV N \\ \N U TG TG CV CV o V1 o 0 0 C7 C? OO 00 00 Oo // 00 O / \ '� \ / TG TG TG TG TG TG TG CV \\ // CV \\ // CV N CV N TG \\ TG N TG \\ TG CV cV N TG \ / TG TG \ / TG SPAN SPAN TG TG TG TG N N N N N M I_I_I ^Y I..L SF STOREFRONT ELEVATION SF3 STOREFRONT ELEVATION SF STOREFRONT ELEVATION SF STOREFRONT ELEVATION SF STOREFRONT ELEVATION 0 Q A5.1 112"=1'-0° A5.1 112"=1'-0" 1/2" A5.1 1/2"=1'-0" A5.1 112"=1'-0" J 1l'-51/2" 4'-5 5/8" 4'-63/4" 9'-31/2" 9'-31/2" 4'-On Q Z OR CID 6' 0" 2" 4'-11 1/2" 2' n 4'-1 5/8" 2' 4'f or -2 3/4" 2' n � n n 1 4 -4 7/8 2" 4'-4 5/8" 2' " 3'-8" 2' W W 4 4 3/4 2 4' 4 3/4" 2 � CV CV CV 04 04 CV w Q o Q CO CV CO CV (O CV // CO CV CO CV CO CV U N TGT TGT TG TGT 2L= TGT SPAN SPAN SPAN I C="l I L F1 STOREFRONT ELEVATION F1 STOREFRONT ELEVATION F1 STOREFRONT ELEVATION F1 STOREFRONT ELEVATION F1 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION 5• 112"=1'-0" 5• 112"=1'-0" 5• 112"=1'-0" A5• 112"=1'-0" A5.1 1/2"=1'-0" A5.1 1/2"=1'-0" 1 l'-51/2" 4'-7 1/8" n 6'-0" 2e 4'-11 1/2" 2' " 1'-1 1/8"2" 3'-0" 2, o_ U Or lrlr E 0 N N 4'-63/4" 9'-31/2" 9'-31/2" 4'-0" o 1. 4' 2 3l4" 2' " 4'-4 3/4" 2" 4'-4 3/4" 2' 4'-4 3/4" 2" 4'-4 3/4" 2' " 3'-8" 2'OR a - CV CV CV CV 3 TG TG 3 CV m / \ V2 ; / \ o o / V3 / \ \ o / \ \ 0 / \ CV \ O Oo O B0 O B0 O OO w M M. w a M oo \ L0 0 w \ / N N 0 TG TG TG TG TG \\ TG CV CV TG 0 - - - - O LU \ / TG TG / o 0 0 o Z, � CV GV = M M M C+M 3 N J m = ui C/) FINISH FLOOR, NTS FINISH FLOOR, NTS FINISH FLOOR, NTS FINISH FLOOR, NTS 8 m Z Z LL L �( 0 F1 STOREFRONT ELEVATION F� STOREFRONT ELEVATION Fl STOREFRONT ELEVATION Fl STOREFRONT ELEVATION Fl STOREFRONT ELEVATION F2 STOREFRONT ELEVATION N 00 °v J A5.1 1/2"=1'-Orr U I_I-I � 1 11 5• 112"=1'-0" 5• 112"=1'-Orr 5. / 112"=1'-Orr LU 8 61/2 nn 8' 611/2" nn 4 1n L1J 6' 6114" ME � CD LU LU 4'-0" 2" 4'-01/2" 2' 4'-01/4 2 4'-0 1/4 2 2y 3'-77/8 L 3'-9 2 6' 2114" 2' a z Q QN - 0 0 ILL w V m W I L H O W � 2 a N N CO CV CO CV CO CV CO CV CO CV CV CV CV N b CV N N N N N d SPAN SPAN SPAN SPAN SPAN TG m , 0 TG a Digitally signed by R S Day e e G g�v Cbert S Da Ilc oC OAND PETE 0 C 9. w • ENGINEERS PLANI�EJS L EV F E L 6'-4" F �p--��n l Rayson g av 9 tal c n fJ .S 1 1 a\/Contact Info:This docu nt as men �[A.J �.J VF1I�^Y electronically signed �qgl touy���ggRo art F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F3 STOREFRONT ELEVATION F3 STOREFRONT ELEVATION o thsd a elnt alre t nrrdi e C and sealed and the s re0u9tlhe ri d F2 STOREFRONT ELEVATION 1 /4" 6'-0" 21 " „_ r „_ , r, U on any elecOiNnicooi ry 5• 112 -1-0" A5.1 112 -1-0 a Date:2021.07.26 15: :36-OCKO' 8'-61/2" N 07/21/2021 " 4' 01/4" 2" 4'-01/4" 2' nn 6'-4" Or Or Or Or lrlr OR OR " 4'-01/4" 2" 4'-01/4" 2' - 2 3'-7718 2 CD " 6'-0" 2-16' 6114" o 0 0 0 N N N TG 4' 1" 40 N d N N N N I- CO CO n n 6'-21/4" 2' N � � NON / \ / \ 2' d O O O O C Z C O O OO O OO O OO e / / \ \ / / \ \ ° ° - = O V W W W / \ / \ a y C ~to U) W > // \\ / \ o 00 / ) 0 W CO En CO En Cfl Cf') / \ w N = N = / / \ o w W Q' C� / o 8 d d m d TG jr TG z° TG TG TG TG TG TG \\ TG TG \\ TG � � o a z o N o l() LC) 2 ti O N 0 e7 o Z W 0 >o " 00 W V Q N O O O \ / \ / p m O N F O Q W ( N U O d 0 (� M M M FINISH FLOOR, NTS FINISH FLOOR, NTS FINISH FLOOR, NTS FINISH FLOOR, NTS FINISH FLOOR, NTS A5 . 1 F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F3 STOREFRONT ELEVATION F3 STOREFRONT ELEVATION A5.1 1/2"=1'-0" A5.1 1/2"=1'-0" A5.1 1/2"=1'-0" A5.1 1/2"=1'-0" A5.1 112"=1'-0" A5.1 112"=1'-0" 07/26/2021 A B C 4 5 6 a )��12 U cn o o 4�4 TOWER PEAK TOWER PEAK _`t CD 33' 4" 33' 4" 1.4 N�� PRE-ENGINEERED ROOF TRUSS FRAMING. RE: STRUCTURAL 12" 12" 5/8"EXTERIOR GRADE 6 6" � � PLYWOOD STANDING SEAM METAL \ a ROOF.RE:A4.0 EXTERIORA �\ FINISH SCHEDULE 1 A3.2 - - - V TOWER BRIG. TOWER BRIG U 26'-10" 26'-10" GUTTER, PERIMETER 4 OF FASCIA 7/8"STUCCO FINISH OVER 3.4# c v` SELF-FURRING GALVANIZED V 7/8"STUCCO FINISH A METAL LATH OVER ONE LAYER I _ OVER 3.4#SELF-FURRING GALVANIZED HIGH DENSITY POLYETHYLENE - METAL LATH OVER ONE LAYER HIGH — BARRIER OVER ONE LAYER A DENSITY POLYETHYLENE BARRIER OVER 3 BUTYL RUBBER MEMBRANE 5/8"EXTERIOR GRADE F.R.T. ONE LAYER BUTYL RUBBER MEMBRANE A6.0 BARRIER OVER 5/8"EXTERIOR PLYWOOD CONT AT TOWER BARRIER OVER 5/8"EXTERIOR GRADE GRADE PLYWOOD SHEATHING I INTERIOR UP TO 48"ABOVE PLYWOOD SHEATHING 5/8"EXTERIOR GRADE I DECK F.R.T. PLYWOOD. CONT.AT RAINSHIELD TOWER INTERIOR UP TO 5/8"EXTERIOR GRADE FIRE 48"ABOVE DECK RESISTANT PLYWOOD SHEATHING AT ENTIRE WALL SURFACE BEHIND SIGN `" AP5 8"METAL STUD. SIGN,BY SIGN zo RE:STRUCTURAL CONTRACTOR I CA � COORDINATE SIGNAGE 5/8"PLYWOOD OVER RIGID � INSULATION 36"X 48"ACCESS HATCH. � 5/8"PLYWOOD OVER RIGID BLOCKING PER MNAG SPRAY-FOAM SEAL ALL RE: DOOR SCHEDULE INSULATION REQUIREMENTS RE: ROOF PLAN,SHEET A3.0 STEEL PENETRATIONS RE:ROOF PLAN,SHEET �� 36"X 48"ACCESS DOOR. _ THROUGH ROOF DECK(TYP.) SINGLE PLY ROOFING A3.0 5 RE: DOOR SCHEDULE SYSTEM OVER RIGID A5.0 O° INSULATION(TYP.) C-0 RE: ROOF PLAN,SHEET A3.0 Y � STEELTUBE JST. BRG. FRONT � � RE:STRUCTURAL 17' 10" W Q INSULATE VOIDS AT BEAMS Z 8"METAL STUD TYP I I I FOAM SEALAY ALL VOIDS WITH I RE-STRUCTURAL STEEL BEAM j RE:STRUCTURAL I STEEL JOIST. GWB TO UNDERSIDE OF I Q Z R30 BATT INSULATION I RE:STRUCTURAL DECKSTYP.)ALL EXT. fi m Z w Q W 7/8"STUCCO FINISH OVER 3.4#SELF FURRING GALVANIZED METAL LATH z Q 8"16-GA. MTL.STUDS 24"O.C. I HEADER INSULATE VOIDS a W OVER ONE LAYER HIGH DENSITY I @ RE:STRUCTURAL 8"16-GA. MTL.STUDS@ 24"O.C. AT BEAM z Q o POLYETHYLENE BARRIER OVER ONE _, _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J Q LAYER BUTYL RUBBER MEMBRANE — — — — — — — — — — — — — — — — — — — — — — — — — — - - - — — - - — — - - — — - - — — I �' N BARRIER OVER 5/8"EXTERIOR GRADE — — T.O.CLERESTORY R30 BATT INSULATION PLYWOOD SHEATHING, BEYOND. - = __ _ = 13'-6" — RE: EXTERIOR ELEVATIONS = _ _ •' 5/8"M.R.GWB CEILING SUSPENDED ACOUSTICAL RECESSED LIGHTING - TILE CEILING RE: ELECTRICAL EXIT SIGN 5/8"M.R. GWB CEILING STOREFRONT SYSTEM PREFINISHED BRAKE METAL OVER ONE LAYER - B.O.CLERESTORY HIGH DENSITY POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER.BRAKE METAL TO MATCH 6 STOREFRONT A5.0 o 8"MTL FRAMING TUBE STEEL BEAM.RE:STRUCTURAL _ B.O. OVERHANG B.O. OVERHANG WHITE STUCCO BAND HEADER 9' 0" 9' 0" BEYOND RE:STRUCTURAL j EXTERIOR LIGHT FIXTURE. 3 FIXTURE SHALL BE SECURED 5 / STOREFRONT PORCH OVERHANG AGAINST MOVEMENT/ ROTATION.RE: ELECTRICAL A6.0 VESTIBULE 25lo 2s STOREFRONT SYSTEM ADHERED MANUFACTURED STONE \� 25 i� �� 00 VENEER BEYOND �� p`9 0 i� \� ADHERED CM � � MANUFACTURED � Lf� co KNOX BOX V2 ��\ VESTIBULE STONE VENEER L J PRE-CAST ADHERED MFD T.O. MULLION&SILL \� T.O. MULLION&SILL STONE WATERTABLE/SILL �� 3' 0" �� - 3' 0" O LU BEYOND �i I `� �� 28 m 0 A7.0 0 o i I i Q 1/2"EXPANSION JOINT i TERRAZZO FLOOR FINISH Z­ TERRAZZO FLOOR FINISH W/SEALANT(TYP) N T.O. FLOOR SLABLLL T.O. FLOOR SLAB ACV Z -• _ Q 0'� - - - ad_ - a ° - _ Qe da <-d � _ _ a- , a � n a a a a, a 1/2"EXPANSION JOINT a' CONCRETE SLAB, W/SEALANT,TYP CONCRETE SLAB, - LO RE: RE:STRUCTURAL 00 0 J U LL W LL W a Q Q U Cn 0 W LU � J o Q z w LEI J QQ Ji LEI a G Digitally signed by R S Day CC®Nyy-p{Robert S Da DO 00016JQ�O LOgERT(cU WAND PETE MRF�F 10 C 12 0, ti _ ENGINEERS PLANNE C�1S A Reason: have rs donu cten. ``J Contact Info:This docu nt as men y electronically signed s 40 b<o ert �[1 Day usfig a Digital S rigo�gpd pi of this document are t n re e 1 TOWER SECTION 2 TOWER SECTION L and sealed and the s urea Ou=e n d U on any wect nic cc i . rryy Date:2021.07.2615: 43-ON't70' 07/21/2021 N 4'-6" o N N N N N O O O O O M N N N N N 2'-3" GL 2'-3" `° i (M C0 o - D N N O N WD.BLOCKING SET UP ROOF CAP FIELD It (0 (0 r- r- LIGHT FIXTURE A FROM BOTTOM EDGE ROOF CAP FIELD LIGHT OF CAP TO ALLOW FABRICATED FROM CAP HIP COVER FABRICATED FROM 00000 FLAT SHEET PROVIDED 5 FOR Z-CLOSURE FLAT SHEET BY MTL ROOF MFR m WRAP W/ICE&WATER I z CONT.SEALANT I I CUT MIN.4 1/2" SHEATHING 8"+/ SHIELD MIDPOINT BLOCKING c r_ N G O MOUNT J-BOX 1 1 DIA. HOLE FOR J 2X PLUS 5/8"PLWD. o L FLUSH W/FACE OF I I BOX - - -------- CAP HIP COVER 2 LAYERS,5/8" ALLOW GAPS IN y w w w \ VENTILATION I SHEATHING = > N cn I I 31/2" BLOCKING FOR AIR MOUNTING BLOCK N ❑ I I OPENING IN FLOW 16 = m I 1 I SHEATHING 2X WD. BLOCKING PEMKO#346C I I sr I 0- � 0- m d METAL ROOF PANEL w w � O w DOOR TOP I I 8 I I g VENTILATED Z- o WEATHERSTRIP, LT FIXT.OUTLINE A6.0 I I A6.0 w Q I I W LENGTH I 4"OCTAGONA\ LEAVE GAPS IN L URE - z I 1 J-BOX BLOCKING FOR AIR I I HIP CAP EXTEND METAL ROOF PANEL 3 FLOW I I UNDER TOP CAP SECTION FRONT VIEW 0 I a VENTILATION OPENING AREA OF ROOF CAP ------------ ICE&WATER SHIELD TOWER PIER LIGHT FIXT.WC1 MOUNTING BLOCK: WIDER HIP COVER IN SHEATHING a a o 0 ROOF HIP 5/8"SHEATHING Z O� CV G n MFR: BORAL A �o U o � Z w NEOPRENE BLOCK MODEL: FLAT TEXTURED CAPSTONE,9" X 20"L o o �, o a ¢ w N COLOR: "TAUPE" ` a o o U NOTES: CUT OPENING FOR 4"OCTAGONAL J-BOX ;L AS SHOWN. CENTER BLOCK ON LT. FIXT. �3� RAIN SHIELD �5� TOWER LIGHT FIXTURE MOUNTING DETAIL �� ROOF CAP PLAN VIEW �7� ROOF CAP PLAN VIEW g TOWER CAP HIP DETAIL A6 . 0 A6.0/ 6"=1'-0" A6.0/ 1"=1'-Orr A6.0 3/8"=1'-01, A6.0 3/8"=1'-0" A6.0 1 1/2"=V-0" 07/26/2021 A A NOTE: ALL EXTERIOR WALLS B TO HAVE R-30 INSULATION a1.0 CD Cl U cn o o .y u � � • (8 cd 17 t� l� k o A3.2 0 Z o o OPP. - N ri T.O. PARAPET — — T.O. PARAPET _ _ T.O. PARAPET 17 T.O. PARAPET 22' 4" 22' 4" 22'-4" A3.2 22' 4" 1� STEEL BEAM STEEL BEAM RE:STRUCTURAL STEEL BEAM RE:STRUCTURAL 5/8"EXTERIOR GRADE FIRE 17 RESISTANT PLYWOOD SHEATHING A3.2 I I I I RE:STRUCTURAL AT ENTIRE WALL SURFACE BEHIND - - SIGN. Q� a 1. STEEL BEAM CEMENT BOARD LAP SIDING OVER ONE LAYER I 7/8"STUCCO FINISH OVER RE:STRUCTURAL HIGH DENSITY POLYETHYLENE BARRIER OVER 3.4#SELF-FURRING ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8"EXTERIOR GRADE I I GALVANIZED METAL LATH PLYWOOD SHEATHING OVER ONE LAYER HIGH .,..� 20 CEMENT BOARD LAP SIDING OVER ONE 20 20 DENSITY POLYETHYLENE Q� 20 SINGLE PLY ROOFING I I A3•2 SINGLE PLY ROOFING LAYER HIGH DENSITY POLYETHYLENE A3.2 A3.2 BARRIER OVER ONE LAYER w SYSTEM OVER RIGID SYSTEM OVER RIGID BARRIER OVER ONE LAYER BUTYL RUBBER BUTYL RUBBER MEMBRANE A3.2 SINGLE PLY ROOFING SINGLE PLY ROOFING INSULATION(TYP.) INSULATION (TYP.) MEMBRANE BARRIER OVER 5/8"EXTERIOR SYSTEM OVER RIGID BARRIER OVER 5/8"EXTERIOR V RE:ROOF PLAN,SHEET RE:ROOF PLAN, SHEET GRADE PLYWOOD SHEATHING SYSTEM OVER RIGID GRADE PLYWOOD SHEATHING INSULATION (TYP.) INSULATION(TYP.) � U A3. A3.0 RE:ROOF PLAN, SHEET \N 8"METAL STUD,TYP RE: ROOF PLAN,SHEET 8"METAL STUD(TYP.) ` �1 RE:STRUCTURAL A3.0� A3.0 RE:STRUCTURAL U JST. BRG. FRONT JST. BRG. FRONT STEEL BEAM. RE:STRUCTURAL v 17'-10" 17'-10" STEEL BEAM. INSULATE VOIDS AT BEAMS JST. BRG. MID FRONT RE:STRUCTURAL I I STEEL JOIST(BEYOND) STEEL BEAM. RE:STRUCTURAL RE:STRUCTURAL STEEL JOIST(BEYOND) STEEL BEAM INSULATE VOIDS AT BEAMS I I STEEL JOIST(BEYOND) RE:STRUCTURAL RE:STRUCTURAL INSULATE VOIDS AT BEAMS RE:STRUCTURAL R30 BATT INSULATION R30 BATT INSULATION(TYP) 1/2"GWB TO UNDERSIDE OF GWB TO UNDERSIDE R30 BATT INSULATION OF DECK OF DECK INSULATE VOIDS AT BEAMS CEMENT BOARD LAP SIDING OVER ONE LAYER _ _ _ _ _ HIGH DENSITY POLYETHYLENE BARRIER OVER 8"METAL STUD - ONE LAYER BUTYL RUBBER MEMBRANE BARRIER A RE:STRUCTURAL 1/2"GWB TO UNDERSIDE OVER 5/8"EXTERIOR GRADE PLYWOOD OF DECK HANGER ROD ANCHOR SHEATHING -2" SIM. - 13 18 TRIM BOARD TYP A7'0 I I R30 BATT INSULATION(TYP.) A7.0 RE: EXTERIOR LIGHT. RE: ELECTRICAL ELEVATIONS T.O.CLERESTORY I [�T.O.CLERESTORY 13'-6" t 13'-6" LIGHT FIXTURE CMp L _jSUSPENDED ACOUSTICAL SUSPENDED ACOUSTICAL RE: ELECTRICAL _Y � 8"METAL STUD TILE CEILING I I TILE CEILING RE:STRUCTURAL Q W Z 19 STOREFRONT SYSTEM 28 C) A7.0 I A3.2 � J TRIM BOARD,TYP RE: J EXTERIOR Q Z ELEVATIONS 00 Z 11' 0" GWB ABOVE Q LU B.O. CLERESTORY I B.O.CLERESTORY — _ _ _ — _ I w 11' 0" z W Q CEMENT BOARD 0 BELOW o w Q O Q CLG HEIGHT, � 10'-0" � FASCIA — — — PANEL — — — — — — — — — — — — — — — — — — — — — — — FFFFFFFFFFFF SUSPENDED ACOUSTICAL — — — 26 — �\ TILE CEILING y 1/2"GWB TO UNDERSIDE B.O. OVERHANG -- OF DECK -- B.O. OVERHANG SOFFIT _j 9' 0"L - - - - - - - - - TUBE STEEL BEAM. RE: A STRUCTURAL a U 0 o I `m 0 3 STOREFRONT SYSTEM DOWNSPOUT 3 BEYOND o TRIM AT DOWNSPOUT PRE-CAST ADHERED MANUFACTURED ONE LAYER HIGH DENSITY lo STONE WATERTABLE/SILL TRIM AT DOWNSPOUT POLYETHYLENE BARRIER OVER STOREFRONT ONE LAYER BUTYL RUBBER SYSTEM — MEMBRANE BARRIER OVER 5/8" o O ONE LAYER HIGH DENSITY EXTERIOR GRADE PLYWOOD 00 POLYETHYLENE BARRIER OVER ONE SHEATHING M LAYER BUTYL RUBBER MEMBRANE LO BARRIER OVER 5/8"EXTERIOR GRADE 4"DOWNSPOUT BEYOND 10 PRE-CAST ADHERED r PLYWOOD SHEATHING A6.1 MANUFACTURED STONE J WATERTABLE/SILL w jk T.O. MULLION&SILL — — o T.O. MULLION&SILL _ � T.O. MULLION&SILL _ — — — _ _ — o _ T.O. MULLION&SILL m 11 3 0 5 3' 0" a O �..0 A6.2 Lu w (� CD w ADHERED MANUFACTURED w ADHERED MANUFACTURED STONE STONE VENEER Z VENEERLu 5 Q cn A6.1 TERRAZZO v�i N Lu 8 5 FLOOR FINISH _ a A6.1 TERRAZZO a N z A6.1 FLOOR FINISH E U) TER ZZO FINISH TERRAZZO 1/2"EXPANSION JOINT CONCRETE SLAB. 5 s m Z 0 FLO R FLOOR FINISH W/SEALANT(TYP) CONCRETE SLAB. RE:STRUCTURAL A U— RE:STRUCTURAL A6.1 T.O. FLOOR SLAB _ / T.O. FLOOR SLAB — ° / � T.O. FLOOR SLAB — — — — — — T.O. FLOOR SLAB = LO 06 J U 0' 0" ° / 0' 0" 0' 0" a d 4a- ° d d d �d d W a - -- -- — — _ - a _ \ Q _d db- LU ILL - U CONCRETE SLAB a / W rn CONCRETE SLAB. J 4 _ — - - a ;< _,a — ° �— Q a U RE:STRUCTURAL -0.d RE:STRUCTURAL _ _ _ a ° - w Lu J d - a 45 Lu J Lu Q Q - Q III III III IIIJi o � w a c=n o _ OF: • II III III III III III III III III III III III III= a Digitally signed by R S Day CN=Robert S Da c� ,OBERT -/Dyp�ooa0000 s 7 go 2 g, t°o ENGINEERS PLANIJE htaC�1S C �p••��n�� I have reviewe i c n. fJ S Contact Info:This docu nt as men �[RA.J \.J �i6Ay Day signed s aW b<o art //F11111"SS y usfig a Digital S n°ea pi hi,,cocrosnt are U •, on enYanta, tin chco t.ur =e ei d 1 FRONT WALL SECTION 2 FRONT WALL SECTION 3 FRONT WALL SECTION T 1r4y 4 WALL SECTION I N � Date.2021.07.26 15 50-ON'BO' A6.1 314"=1'-0" °• 314"=1'-0" 314"=1'-0" 314"=1'-0" � a LAYER OF HIGH-DENSITY ADHERED MANUFACTURED > 07/21/2021 SEALANT&BACKER ROD. 30#ELASTOMERIC SELF ADHERED MANUFACTURED N o POLYETHYLENE BARRIER STONE VENEER (MATCH STOREFRONT ADHERING MEMBRANE WRAP 12" STONE VENEER OVER ONE LAYER o OVER ONE LAYER OF BUTYL I 5/8"EXTERIOR GRADE SEALANT COLOR) UP SHEATHING AND 8"DOWN HIGH DENSITY POLYETHYLENE o 0 0 0 0 RUBBER MEMBRANE OVER Q ALUMINUM STOREFRONT W/ FOUNDATION BARRIER OVER ONE LAYER BUTYL m N N N N N PLYWOOD SHEATHING. A I - p � c) c) 00 5/8"EXTERIOR GRADE I ' BRAKE METAL TO SPANDREL GLASS PANEL I' RUBBER MEMBRANE BARRIER N N o N PLYWOOD SHEATHING. IC A D A ER S IL F 0 1 __, ALUMINUM STOREFRONT MATCH STOREFRONT I OVER 5/8"EXTERIOR GRADE 0 0 0 0 0 ABOVE SLAB TO 8"BELOW SLAB. FRAME SEALANT ICE AND WATER SHEILD I PLYWOOD SHEATHING ALUMINUM GLAZING SEALANT&BACKER ROD. 30#ELASTOMERIC I i� FRAME MATCH STOREFRONT QUARTZ"COARSE CARRERRA" FROM 12"ABOVE SLAB TO 8" I' 1"INSULATED SELF-FURRING GALV. LATH& D SELF-ADHERING I 20 GA.SS SHEET OVER ICE AND i ° ° SEALANT COLOR SILL BY CABINET VENDOR BELOW SLAB. I °' TEMPERED GLAZING I ' SCRATCH COAT. EXTEND TO MEMBRANE.WRAP 12 I WATER SHEILD FROM 12"ABOVE TO 8" / 1/2" 1"INSULATED TEMPERED y 0 Z UP SHEATHING AND 8" I I BREAK SHARP EDGES FOUNDATION c O BELOW SLAB. SECURE W/NEOPRENE I I GLAZING 1/2"TERRAZZO WRAP BRAKE METAL PRE-CAST ADHERED STEEL COLUMN _ "'' v) SEALANT& I MIN.6"DOWN SLAB MANUFACTURED STONE W/R1/8"ROUND-OVER 20 GA. SS SHEET OVER ICE AND � g -L � RE:STRUCTURAL w � > DOWN FOUNDATION ---- FASTENERS AT THE TOP AND TEK 1/2"TERRAZZO CONC. SLAB ON �—n �_ WATER SHEILD FROM 12 V w W w ' @ BACKER RODS ` '= ;' EDGE BRAKE METAL TO WATERTABLE/SILL L� T.O. SILL ' SCREWS AT THE BOTTOM 12 O.C. — ( 0 � v� o Q i VAPOR RETARDER MATCH STOREFRONT — PVC WEEP SCREED, ABOVE TO 8 BELOW SLAB. - 1­— PVC WEEP SCREED, L _ i CONC. SLAB ON ) 5 - o SIMPSON A 21 OR MIN.22 GA. 3' 0"A.F.F. SECURE W/NEOPRENE m w ° VAPOR RETARDER 3/4" COLOR:WHITE o COLOR:WHITE SCRATCH COAT. _— CONT. MTL SUPPORT BRACKET _ FASTENERS AT THE TOP AND > w 8"METAL STUDS o CONCRETE SIDEWALK. �� _ - 4- d` : = W/HOLDING CAPACITY 5 LBS/LF. ———————— 1/2"TERRAZZO TEK SCREWS AT THE BOTTOMLu Lu m a I CONT. MTL FLASHING W/HEMMED RE:CIVIL °' d = ="a -° - a° °° Y -` _ + - ACROVYN EDGING , SIMPSON A 21 BRACKETS SHALL CONC. SLAB ON ° d ° + LANDSCAPING - @ 12"O.C. 1/2"TERRAllO EDGES(HOLD FROM FRONT OF STONE -Q .°- ° -• ad- a _ a ' , a" + MATERIAL BE SPACED AT 16"O.C.OR 2 CASEWORK OUTLINE. ° ,d 4 a q _ d_ ( ) RE:SHEET EQ. VAPOR BARRIER LAP HIGH DENSITY POLYETHENE Z Q 1/4"MIN. SET IN A BED OF SEALANT 1/2"EXPANDABLE FILLER d ° a °_ , ,-,•a + + BRACKETS PER SILL PIECE. cllj CONC.SLAB ON RECESSED&SEALANTED dy d BARRIER OVER FLASHING VAPOR BARRIER - - d BRACKETS SHALL BE ATTACHED HSS 8x4x3/16. ; "' 4"REQUIRED @ GRADE a 4 - a°, ° d m a USING GALVANIZED SCREWS, RE:STRUCTURAL a d d- s° 4"REQUIRED @GRADE a ° CONDITION a<Q ; a °a .d4': ° "dd d.• PENETRATING STUD MIN 1" a` d- o d --a a;° a " �_ THICKENED SLAB AT „ ° d° p' d _ 8"METAL FRAMING -a - CONDITION a da SIDEWALK = a d ONE LAYER HIGH DENSITY 1/2"GWB ° ` °D CONT. MTL FLASHING W/ =a O o N 4- STOREFRONT _ e a d_ °� - ° o Z N Q _ °^ SEAL WITH SIKAFLEX SL ° _ ;, ° ` " ° d POLYETHYLENE BARRIER OVER ONE ACROVYN a O O O HEMMED EDGES(HOLD FROM � N W o O O o - ' THICKENED SLAB AT LAYER BUTYL RUBBER MEMBRANE _ FRONT OF STONE 1/4"MIN.) `—'� Lu 7 Z a, ° < _. 4 GRAVEL o- a a $ ', a' ' ' .- O � w a tYi Q N = a ,; �Q��Q °a d STOREFRONT ON 5/8 EXT. PLWD SHEATHING R 30 R30 BATT INSULATION A _' a = SET IN A BED OF SEALANT g o �, o a Q w c� N ° 6 Go °a ° (' ('� POLY FOAM EXP.JOINT A 4 ' :' a . ° ,_ -a d LATH/SCRATCH COAT SIDEWALK �. ,d•" ° III III III III III III I ° dP ` - ADHERED MFD STONE VENEER WHERE GLAZING FRAME IS FLUSH WITH SHEATHING e''d " =° _ 4° SEAL WITH SIKAFLEX SL ' ' _FOUNDATION.RE:STRUCTURAL 5/8"BITUMINOUS EXPANSION JOINT. A6 . 1 5 PERIMETER BASE DETAIL g SECTION AT STOREFRONT GLAZING 9 SECTION AT STOREFRONT GLAZING AT LANDSCAPING 10 SILL DETAIL KNEE WALL BASE FLASHING IS COLUMNS • 1 112"=1'-0" 1 112"=1'-0" 1 112"=1'-0" A6.1 1 1/2"=1'-0" A6.1 1 1/2"=V-0" 07/26/2021 NOTE: ALL EXTERIOR WALLS TO HAVE R-30 INSULATION o 8 G F 1 � � U U cn o o .y 0 oo k U. 00 St STEEL BEAM T.O. PARAPET — — — — — — — — T.O. PARAPET �0.4ARAPET RE:STRUCTURAL A3 217 STEEL BEAM 17 RE:STRUCTURAL STEEL BEAM RE:STRUCTURAL ' _ STANDING SEAM METAL ROOF, RE: 12 A3.2 _ A4.0 ARCH EXTERIOR FINISH I SCHEDULE � � CEMENT BOARD LAP SIDING OVER 5/8"EXTERIOR GRADE ONE LAYER HIGH DENSITY PLYWOOD POLYETHYLENE BARRIER OVER ONE LAYER BUTYL RUBBER TRUSS FRAMING, RE: I SINGLE PLY ROOFING MEMBRANE BARRIER OVER 5/8" EXTERIOR GRADE PLYWOOD SINGLE PLY ROOFING STRUCTURAL I SYSTEM OVER RIGID INSULATION (TYP.) � U SHEATHING SYSTEM OVER RIGID - - SINGLE PLY ROOFING RE:ROOF PLAN, SHEET INSULATION(TYP.) 13 SYSTEM OVER RIGID RE: ROOF PLAN,SHEET A3 2 INSULATION(TYP.) U RE: ROOF PLAN,SHEET �--+ 8"METAL STUD 3' v RE:STRUCTURAL A3.0 R30 BATT INSULATION STEEL BEAM, RE:STRUCTURAL STEEL BEAM. RE:STRUCTURAL INSULATE VOIDS AT BEAMS TRIM BOARD TYP INSULATE VOIDS RE: EXTERIOR ELEVATIONS I I AT BEAMS STEEL BEAM. R30 BATT INSULATION 1/2"GWB TO UNDERSIDE RE:STRUCTURAL O OF DECK INSULATE VOIDS AT BEAMS - o SIGN, BY SIGN I I STEEL JOIST(BEYOND) CONTRACTOR I I RE:STRUCTURAL R30 BATT INSULATION 13 A7.0 5/8"EXTERIOR GRADE FIRE 1/2"GWB TO,, RESISTANT PLYWOOD SHEATHING AT I I UNDERSIDE OF DECK ENTIRE WALL SURFACE BEHIND SIGN R30 BATT INSULATION --- _____ ' T.O.CLERESTORY - ch CEMENT BOARD LAP SIDING OVER W o 3' 6" 5/8"EXTERIOR GRADE I I L__ _J ONE LAYER HIGH DENSITY _Y o SUSPENDED ACOUSTICAL PLYWOOD SHEATHING TILE CEILING I I POLYETHYLENE BARRIER OVER Q STOREFRONT SYSTEM ALL JOINTS,GAPS,OR SPACES ONE LAYER BUTYL RUBBER 1/2"GWB TO LLI — LEADING FROM BUILDING/VESTIBULE I I MEMBRANE BARRIER OVER 5/8" UNDERSIDE C) Z EXTERIOR GRADE PLYWOOD O SHIM AS REQUIRED TO TOWER SHALL BE SEALED OF DECK SHEATHING � � TRIM BOARD,TYP 19 7/8"STUCCO FINISH OVER 3.4#SELF- I I 3/4"PLYWOOD DECKING J >- RE: EXTERIOR ELEVATIONS A7.0 FURRING GALVANIZED METAL LATH _ LIGHTING FIXTURE, - OVER ONE LAYER HIGH DENSITY I I 0¢0 Z 2X WOOD BUCK POLYETHYLENE BARRIER OVER ONE I I 8" 16 GA.MTL STUDS w Q ~ _ RE: ELECTRICAL _ _ _ B.O.CLERESTORY LAYER BUTYL RUBBER MEMBRANE @ mi U 3/4"PLYWOOD 16"O.C. ¢ W SINGLE PLY 11,-0" BARRIER OVER 5/8"EXTERIOR GRADE I I z � Q ROOFING SYSTEM. �R— PLYWOOD SHEATHING 8" 16 GA.MTL z Q RUN UP WALL 8"MIN. I I STUDS @ 16"O.C. w o Q 15 N 1/2"GWB A7.0 — — CEILING: 2X2 ACT TUBE STEEL BEAM — — — — — 5/8"M.R.GWB CEILING CEILING, RE:STRUCTURAL — — — — — — — — — — — 8"MTL FRAMING @ 16"O.C. B.O.OVERHANG 9'-01. 10 - - - - - S FF T L A9.0 28 SOFFIT A ACCENT BEYOND PER FINISH SCHEDULE RE: A3.2 SH ET A4 0 EXTERIOR LIGHT FIXTURE. FIXTURE SHALL BE o SECURED AGAINST MOVEMENT/ROTATION. RE: C ff ELECTRICAL 3 5 \ i PT i ACCENT TRIM BEYOND, 3 PER FINISH CHEDULE. RE:SHEE A .0 \ A \ PRE-CAST ADHERED MANUFACTURED STONEo c, WATERTABLE/SILL - STOREFRONT SYSTEM \ STOREFRONT SYSTEM \ ONE LAYER HIGH DENSITY ADHERED MANUFACTURED �I POLYETHYLENE BARRIER 00 nneN OVER ONE LAYER BUTYL o M STONE VENEER RUBBER MEMBRANE \ BARRIER OVER 5/8" \ EXTERIOR GRADE PLYWOOD m J SHEATHING mow�// PRE-CAST ADHERED m LL MANUFACTURED STONE WATERTABLE/SILL o A16:2: - LU I I 30 / o 0 A9.0 w / ow Z I � � w �. � Q o N / co w O = 5 I I I TERRAZZO FLOOR FINISH / a :A6:1: : ::: :?t::: ::?::: o CN Z A6.1 / ADHERED MANUFACTURED E (� CONCRETE SLAB, s CONCRETE SLAB / RE:STRUCTURAL STONE VENEER TERRAZZO c m Z 0 -FLOOR FINISH - LL Lz RE:STRUCTURAL / — — 1 00 0 J r 1 T.O. FLOORLIT.O.FLOOR SLAB T.O. FLOOR SLAB _ .. d. ,. ° . d - a _ d, - _ da _ _ 0'-On n - d. a d - a a W W L� •-d_, "•4•. aq _ - ad - d - - b e - - d' - :q• a a d - - L \ 41 1/2"EXPANSION JOINT qy ° b Q W co -1/2"EXPANSION I W/SEALANT,TYP : _ ti ' e` o W U J J - Ad ' a a d J J zQQ � � Q W/SEALANT,TYP — —RE:STRUCTURAL r E � w - - - E O LL o w - - - o IIIIII—III— III—IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII—III - -_ -_ — — — q ,• Digitally signed ert S Da S JDDaQaay�y El �El El El El DOIII III III III III LpgERT 0-CI9P#9AND PETE MAF F l0 C 0 III III III III III III III III III III III III III III III III III III III III III III III III III I N • . pp Y Reasl SEER have re e� c` n I� " Dlaytusfi9aal signed S Contact MI.This cu sn4 r0 bo g<�go Pi (, of this document are t in e 4� SIDE WALL SECTION t v and sealed and the s eJ��@u9tlhe ri d 1� SIDE WALL SECTION 3 REAR WALL SECTION Date221.07.2615:1 57-0(40- A16J.2 3/4"=1'-01, 07/21/2021 o CEMENT BOARD LAP SIDING OVER 7/8"STUCCO FINISH OVER 3.4#SELF- ONE LAYER HIGH DENSITY FURRING GALVANIZED METAL LATH METAL FRAMING N N N N N 15/16"ANCHOR RE:STRUCTURAL METAL STUDS y o 0 0 0 0 POLYETHYLENE BARRIER OVER OVER ONE LAYER HIGH DENSITY o o � M N N N N N ONE LAYER BUTYL RUBBER POLYETHYLENE BARRIER OVER ONE � CO CO 00 BOLT HOLE ONE LAYER HIGH DENSITY N D N N o N It (0 (0 r- MEMBRANE BARRIER OVER 5/8" LAYER BUTYL RUBBER MEMBRANE 41/2" POLYETHLENE BARRIER 5/8"EXTERIOR PLYWOOD 0 0 0 0 0 EXTERIOR GRADE PLYWOOD II BARRIER OVER 5/8"EXTERIOR GRADE _ -,- '_ ;- : _ SHEATHING II PLYWOOD SHEATHING OVER ONE LAYER BUTYL SHEATHING OVER METAL BASE PLATE TOP VIEW _ 7/8"THICK 3-COAT STUCCO ( I RUBBER MEMBRANE STUDS r FINISH IN ACCORDANCE 1 BARRIER OVER 5/8" AMICO SCREED, II WITH FLORIDA BUILDING - _ II AMICO SCREED,AMMWS-780-780, } PLYWOOD SHEATHING ,t ONE LAYER HIGH-DENSITY cn c p AMMWS-780-780,COLOR: I I I CODE CHAPTER 25&ASTM _ CONT.8"HORIZONTAL COLOR:WHITE POLYETHYLENE BARRIER OVER ONE 2 "'' WHITE �I I C926 STUCCO"BROWN"COAT, LAYER BUTYL RUBBER MEMBRANE ci •y V w > STEEL STUD HT. r w w I @ I LEVELING COAT U) SEALANT SEALANT UNDER SCREED REQ.'D I 3'-0"A.F.F. 4"SCHEDULE I 3.4#SELF-FURRING METAL a ,L N UNDER SCREED 40 PIPE w I LATH INSTALLED IN -; _ - N m REQ.'D CONT.8"HORIZONTAL MINIMAL GAP > I '' _ ' MINIMUM 1 1/4"OVERLAP STEEL STUD @ HT.3'0" Q o I ACCORDANCE WITH I STUCCO SCRATCH BASE y '; w w w o w FLORIDA BUILDING CODE COAT OVER SELF FURRING o � m a MINIMAL GAP I A.F.F. I PRE-CAST ADHERED o I CHAPTER 25 METAL LATH — FIBER CEMENT LAP SIMPSON A 21 OR MIN.22 m 4-1/2"SLEEVE a I SIDING COORDINATE ° PRE-CAST ADHERED SIMPSON A-21 OR MIN.22 GA. MANUFACTURED STONE J I ( z I = OVER 4"PIPE J MANUFACTURED I CONT. MTL SUPPORT BRACKET W/ GA.CONT.MTL SUPPORT I WATERTABLE/SILL m I ONE LAYER HIGH-DENSITY I STUCCO FINISH COAT WITH MFR'S CURRENT a STONE �� I HOLDING CAPACITY 5 LBS/LF. BRACKET W/HOLDING I = I POLYETHYLENE BARRIER I•, RE: ELEVATIONS MIAMI DADE NOA) ADHERED MANUFACTURED STONE �, :. .` WATERTABLE/SILL SIMPSON A-21 BRACKETS SHALL CAPACITY 5 LBS/LF. I VENEER j OVER ONE LAYER BUTYL CONCEALED FASTENER MIN. SIMPSON A-21 BRACKETS BE SPACED AT 16"O.C.OR(2) j I RUBBER MEMBRANE BARRIER ;�` ;A' `;.r NO.8-18,0 0.375"HEAD X ADHERED SHALL BE SPACED AT 16" 2.5#SELF-FURRING GALVANIZED 1/2"THICK MANUFACTURED STONE I :- BRACKETS PER SILL PIECE. I I } 7/8"TOTAL STUCCO ;° 1-3/4"LONG BUGLE-HEAD a a VENEER I O.C.OR 2 BRACKETS METAL LATH BASE PLATE I _ BRACKETS SHALL BE ATTACHED ( ) I o N PER SILL PIECE. I I THICKNESS SCREW o� z o USING GALVANIZED SCREWS, — MORTAR SCRATCH COAT AND I I I A EXPOSED FASTENER MIN.0.075" o z Y BRACKETS SHALL BE w PENETRATING STUD MIN 1 SETTING BED 5/8 EXTERIOR-GRADE 3.4#SELF FURRING METAL w SHANK X 2 LONG CORROSION 2.5#SELF FURRING I I ° a v o ATTACHED USING ° o �, o a Q GALVANIZED METAL LATH I I a< PLYWOOD SHEATHING LATH INSTALLED IN a _ GALVANIZED SCREWS, I ONE LAYER HIGH DENSITY OVER 8"METAL STUDS ACCORDANCE WITH RESISTANT METAL STUD FINISH NAIL a o o MORTAR SCRATCH COAT PENETRATING STUD MIN I POLYETHYLENE BARRIER OVER a (PIN) BOLLARD COVER FLORIDA BUILDING CODE AND SETTING BED 1" ONE LAYER BUTYL RUBBER CHAPTER 25. NOTE: BOTH CONCEALED AND EXPOSED FASTENERS SHALL BE ONE LAYER HIGH DENSITY MEMBRANE BARRIER OVER 5/8" BOLLARD ELEVATION SPACED 7"O.C. MAX.VERICALLY AND 16"O.C. HORIZONTALLY POLYETHYLENE BARRIER OVER EXTERIOR GRADE PLYWOOD A6 . 2 ONE LAYER BUTYL RUBBER SHEATHING MEMBRANE BARRIER OVER 5/8" 5 STONE DETAIL SIDING EXTERIOR GRADE PLYWOOD 6 STONE DETAIL STUCCO 7 GENERATOR BOX BOLLARD DETAIL g STUCCO DETAIL TYP. g LAP SIDING HVHZ DETAIL A6.2 3"=1r_Orr A6.2 1 1/2"=V-0" A6.2 1 112"=1'4" A6.2 1 112"=1'4" 07/26/2021 STEEL COLUMN CONT.2X P.T.WOOD BUCKS RE:STRUCTURAL 8"METAL STUDS @ 16" SHALL BE ATTACHED USING 7.8 MIN. R-13 BATT. HILTI KWIK-PRO SELF DRILLING ACROVYN OVER 1/2"GWB 2 26 INSULATION O.C.TO UNDERSIDE OF 26 SCREWS S-WW 14X20X2 3/4" 26\ I DECK A9'0 PFH#4 WINGS @ 18"O.C. 26 A9.0 a N 6"X 6"ACCESS A9.0 Cl OVER 1/2"GWB PANEL. 1/4"METAL BRACKET ACROVYN OVER 1/2"GWB __ _______________ �,_ �, Cl FOR PIPE SUPPORT - ----------- -- 26 l� R30 BATT INSULATION -- ------ ----------- ----- 4"CA TYP ACROVYN OVER 1/2 GWB ACROVYN OVER 1l2 GWB cy O „ SHIM AS READ O O ,.,_.,•_,< __,_,,.,_,, _", , , ,_• i _ CAPPED PVC CONT PERIMETER I;, ' ��" "• I xx THROUGH WALL A9 0 \ II I SEALANTING ` I PIPE. -IL---- - CONT. PERIMETER SEALANTING I ''� CONT. PERIMETER SEALANTING II II SHIM AS REQ'D STOREFRONT SYSTEM w - STOREFRONT SYSTEM STOREFRONT SYSTEM CONT. SEALANTING,TOP AND SIDES C cd o SHIM AS REQ'D I I ; j �, / O O \ �� EXTERIOR WATER A I SERVICE ROOM \-" SHIM AS REQ'D - / I MTL.STUD FRAMING IN THIS AREA AS I REQ'D FOR ATTACHMENT OF MFD STONE VENEER � I o STOREFRONT SYSTEM TO STRUCTURE 8"METAL STUDS ---------- I I FIBER CEMENT LAP SIDING OVER ONE SETTING BED W/SELF I BRAKE METAL OVER ONE LAYER HIGH LAYER HIGH DENSITY POLYETHYLENE STOREFRONT SYSTEM FURRING, PAPER BACKED / I I , ATTACH STOREFRONT / CONT.SEALANTING,TOP AND DENSITY POLYETHYLENE BARRIER OVER a 8"CONTINUOUS METAL PER NOA/FLORIDA / SIDES ONE LAYER BUTYL RUBBER MEMBRANE GALV. METAL LATH RUNNER PRODUCT APPROVAL BRAKE METAL OVER ONE LAYER BARRIER OVER 5/8"EXTERIOR GRADE BARRIER OVER ONE LAYER BUTYL � RUBBER MEMBRANE BARRIER OVER 5/8" V� CONT.SEALANTING,TOP AND SIDES I HIGH DENSITY POLYETHYLENE PLYWOOD SHEATHING. BRAKE METAL EXTERIOR GRADE PLYWOOD SHEATHING I I ;R30 BATT INSULATION FINISHED FLOORING CONT. SEALANTING, I BARRIER OVER ONE LAYER FILLER ANGLE TO MATCH STOREFRONT. PRE-CAST ADHERED MANUFACTURED BRAKE METAL OVER ONE LAYER HIGH TOP AND SIDES - BUTYL RUBBER MEMBRANE WRAP SUBSTRATE AND TERMINATE STONE WATERTABLE/SILL(BELOW) DENSITY POLYETHYLENE BARRIER OVER BARRIER OVER 5/8"EXTERIOR BEHIND STOREFRONT FRAME FIBER CEMENT ACCENT TRIM ONE LAYER BUTYL RUBBER MEMBRANE 8"NESTED MTL GRADE PLYWOOD SHEATHING. 20 9" O� RE: EXT. ELEVS BARRIER OVER 5/8"EXTERIOR GRADE STUDS 20 BRAKE METAL FILLER ANGLE TO A7.0 C ` PLYWOOD SHEATHING. BRAKE METAL A7.0 - MATCH STOREFRONT.WRAP NOTE:CENTER STOREFRONT V FILLER ANGLE TO MATCH STOREFRONT. q SUBSTRATE AND TERMINATE \10j STOREFRONT PLAN DETAIL WRAP SUBSTRATE AND TERMINATE 2 WATER HOOKUP DETAIL 3 STOREFRONT PLAN DETAIL BEHIND STOREFRONT FRAME �1 STOREFRONT PLAN DETAIL BETWEENICOLUMNS&BLOCKING \�N ( A7.0 BEHIND STOREFRONT FRAME _ ` �1•� 3"=1'-0' A7.0 1 112"=1'-0" A7.0 3"=1'-0" A7.0 3"=1'-0" CONT.2X P.T.WOOD BUCKS CONT. v Q, CONT.2X WOOD BUCKS SHALL BE ATTACHED USING SEALANT,TOP SHALL BE ATTACHED USING HILTI KWIK-PRO SELF DRILLING AND SIDES H.M. DOOR HILTI KWIK PRO SELF SCREWS S-WW 14X20X2 3/4"PFH BRAKE METAL OVER ONE H.M. DOOR FRAME R30 BATT INSULATION MC8-SEE STRUCT. DRILLING SCREWS S-WW #4 WINGS @ 18"O.C. LAYER HIGH DENSITY MIN. R-30 ` POLYETHYLENE BARRIER 2x P.T.BLOCKING A 14X20X2 3/4"PFH#4 WINGS @ \ FIBER CEMENT LAP SIDING OVER ONE LAYER HIGH 18"O.C. CONT. PERIMETER SEALANT, OVER ONE LAYER BUTYL SEALANT ' DENSITY POLYETHYLENE BARRIER OVER ONE STOREFRONT 1/2"GWB BOTH SIDES RUBBER MEMBRANE BARRIER FRP EDGE TRIM (TYP.) SYSTEMMEN LAYER BUTYL RUBBER MEMBRANE BARRIER OVER OVER 5/8"EXTERIOR GRADE FRP WALL PANNEL 8"METAL STUDS PLYWOOD SHEATHING. 5/8"EXTERIOR GRADE PLYWOOD SHEATHING CONTINUOUS BRAKE METAL FILLER ANGLE FRP CORNER TRIM(TY SHIM AS RE:STRUCTURAL PERIMETER TO MATCH STOREFRONT. --- " REQUIRED _ - -- - - SEALANTING WRAP SUBSTRATE AND PRE-CAST ADHERED MANUFACTURED _ _ STONE WATERTABLE/SILL TERMINATE BEHIND STOREFRONT FRAME 1/2"GWB FIBER CEMENT ACCENT TRIM PRE-CAST ADHERED FRP WALL PANNEL SHIM,AS REQ'D MANUFACTURED STONE CONT.2X P.T.WOOD BUCKS SHALL BE WATERTABLE/SILL METAL STUD WALL ATTACHED USING HILTI KWIK-PRO FRAMING SELF DRILLING SCREWS S-WW ADHERED MANUFACTURED 1/2"GWB 14X20X2 3/4"PFH#4 WINGS @ 18"O.C. STONE VENEER OVER ONE R30 BATT INSULATION CONT. 8"NESTED MTL LAYER HIGH DENSITY M BRAKE METAL OVER ONE LAYER HIGH DENSITY SEALANT,TOP `= STUDS POLYETHYLENE BARRIER A LU o CONT. PERIMETER SEALANT POLYETHYLENE BARRIER OVER ONE LAYER BUTYL AND SIDES OVER ONE LAYER BUTYL RUBBER MEMBRANE BARRIER OVER 5/8"EXTERIOR 1/2"CPVC TRIM R30 BATT INSULATION RUBBER MEMBRANE Q GRADE PLYWOOD SHEATHING. BRAKE METAL TO BRAKE METAL OVER ONE LAYER HIGH MIN. R-30 BARRIER OVER 5/8" LU Z MATCH STOREFRONT 1"CPVC TRIM WRAP SUBSTRATE AND DENSITY POLYETHYLENE BARRIER SEALANT AT SILL EXTERIOR GRADE O Q TERMINATE BEHIND STOREFRONT FRAME 5/8"EXTERIOR GRADE OVER ONE LAYER BUTYL RUBBER PLYWOOD SHEATHING 2EE J PLYWOOD SHEATHING STOREFRONT SYSTEM MEMBRANE BARRIER OVER 5/8" BACKER ROD&SEALANT � >- CONTINUOUS SEALANTING,TOP AND EXTERIOR GRADE PLYWOOD 1-1/2"MTL STUDS J U) SIDE SHEATHING. BRAKE METAL FILLER Q Z ANGLE TO MATCH STOREFRONT. 00 Z 27 STOREFRONT PLAN DETAIL 10 JAMB BEHIND CLERESTORY BSTRATEANDTERMINATE 11 DETAIL AT STONE 12 FRP CORNER DETAIL EXTERIOR DOOR w Q ULU BEHIND STOREFRONT FRAME A7.0 3"=1'-01, A7.0 3"=1'0" z 3: Q 4"DOWNSPOUT 7/8"STUCCO FINISH OVER 3.4#SELF-FURRING i \ N RE: ELEVATIONS GALVANIZED METAL LATH OVER ONE LAYER HIGH Gj CEMENT BOARD LAP SIDING OVER ONE \ 1 STEEL I-BEAM. LAYER HIGH DENSITY POLYETHYLENE B SEALANT VOID WITH SIKAFELX DENSITY POLYETHYLENE BARRIER OVER ONE LAYER RE:STRUCTURAL CEMENT BOARD LAP SIDING BARRIER OVER ONE LAYER BUTYL RUBBER BATT. INSUL. BUTYL RUBBER MEMBRANE BARRIER OVER 5/8" OVER ONE LAYER HIGH CEMENT BOARD LAP SIDING OVER MEMBRANE BARRIER OVER 5/8"EXTERIOR MIN. R-30 PROVIDE BACKER ROD EXTERIOR GRADE PLYWOOD SHEATHING. DENSITY POLYETHYLENE ONE LAYER HIGH DENSITY GRADE PLYWOOD SHEATHING ' I POLYETHYLENE BARRIER OVER � LIGHT GUAGE METAL BARRIER OVER ONE LAYER I _ LAP SIDING AS SCHEDULED SIDEWALK 2X4'S @ 24"O.C. FRAMING SECURED TO BUTYL RUBBER MEMBRANE ONE LAYER BUTYL RUBBER STARTER STRIP RE: EXTERIOR ELEVATIONS RE:STRUCTURAL STRUCTURE ABOVE BARRIER OVER 5/8" MEMBRANE BARRIER OVER 5/8" STARTER STRIP P.T.2X8 OVER WATER I RE:STRUCTURAL EXTERIOR GRADE EXTERIOR GRADE PLYWOOD IFLASHING EXTEND 4"UP 6"PVC PIPE CONNECTED TO BARRIER CUT TOP TO PLYWOOD SHEATHING SHEATHING WALL BEHIND LAP SIDING UNDERGROUND STORMWATER SLOPE AWAY FROM BLDG. L--L FLASHING. EXTEND 4"UP i 1' 1" SYSTEM SET FLUSH W/SIDEWALK RE:STRUCTURAL WALL BEHIND LAP SIDING CONTINUOUS SEALANT BRAKE METAL COPING,TURN STARTER STRIP ° CONT.2X WOOD BUCKS /14 DOWNSPOUT DETAIL @SIDEWALK UP WALL 8"MIN. - 1� I FLASHING CONTINUOUS SEALANT = E SHALL BE ATTACHED USING ��A .`O� ONE LAYER OF HIGH DENSITY HILTI KWIK PRO SELF _ 1 112"=1'-0" POLYETHLENE BARRIER OVER 5/8"PLYWOOD SHEATHING - 0 I_ DRILLING SCREWS S WW 6"TRIM. ONE LAYER BUTYL RUBBER N SEE ELEVATIONS 14X20X2 3/4"PFH#4 WINGS @ UNVENTED ALUMINUM - , 18"O.C. 4"DOWNSPOUT MEMBRANE OVER 5/8' PANEL SOFFITS THIS AREA (V 3 RE: ELEVATIONS EXTERIOR GRADE PLYWOOD SUBSTRATE AS SCHEDULED r SHIM AS REQ'D SHEATHING - - - 3 T.O.CLERESTORY - R30 BATT INSULATION 1 1 2" KIN BAR ( IZ '4111, SEALANT VOID WITH SIKAFELX - VARIES) i ud 13' 6" FLUSH FACE EXTENDER 22 GA. - - I - - - CONT.SEALANTo A PROVIDE BACKER ROD GALV. MATERIAL(12'-0" o STARTER STRIP 6"FIB R E EN TRIM LENGTHS) - - SOFFIT PANEL I FLASHING LANDSCAPE N I GENERATOR BOX CONTINUOUS SEALANT 0,CONT.SEALANT,TOP AND J-MOLDS FIBER CEMENT SIDING RE: ELECTRICAL , SIDES B.O. OVERHANG I TRIM PAINT TO MATCH 0 0 I = 1X AZEK TRIM HARDIE SIDING °' 8"NESTED MTL STUDS 6"PVC PIPE CONNECTED TO 9'-0" N COLOR:WHITE DRIP FLASHING 00 I I UNDERGROUND STORMWATER SOFFIT PANEL ¢ M CONT. PERIMETER SEALANT SYSTEM. EXPOSED PORTION OF CONT.22 GA GALV.CLEAT J-MOLDS WRAP ONE LAYER HIGH DENSITYLO L1 L. PIPE TO BE WHITE (12'0"LENGTHS) POLYETHYLENE BARRIER AND ONE 13 STOREFRONT HEAD 148 DOWNSPOUT DETAIL LANDSCAPING 15 REAR TOWER TRIM ' 16 EXTERIOR SOFFIT DETAIL LAYER BUTYL BARRERUNDERBOTTOMOBRANE 17 DETAIL AT GENERATOR BOX 1g 1 EXTERIOR DEVICE MOUNTING DETAIL T , ■ A7.0 3"=1'.0" A7. 1 112"=1'-0" A7.0 1 1/2"=11 A7.0 ! 1 1/2"=V-0" SOFFIT A7.0 3"=1'.0" A7.0 j 3"=11 m L. O STOREFRONT SYSTEM 11 SIM. CONT.2X P.T.WOOD BUCKS STOREFRONT SYSTEM CONT.2X P.T.WOOD BUCKS STUCCO J-MOLD @ COLOR CHANGE m " B CONT. PERIMETER SHALL BE ATTACHED USING (n CONT. PERIMETER A7.0 HILTI KWIK PRO SELF DRILLING CONT. PERIMETER SEALANT 11 SHALL BE ATTACHED USING PROVIDE END DAMS @ SILL,TYP SEALANT SEALANT A7.0 HILTI KWIK-PRO SELF SEALANT BRAKE METAL OVER 1/2"GWB SCREWS S WW 14X20X2 3/4" BRAKE METAL OVER 1/2"GWB DRILLING SCREWS S-WW 41/8" 6 SHIM,AS REQ'D PFH#4 WINGS @ 18"O.C. _ U) R30 BATT INSULATION 6 14X20X2 3/4"PFH#4 WINGS @ •• 0 J BATT. INSUL. R30 BATT INSULATION 18"O.C. �, 1/2"SLOPE o O <_ CONT.SILL FLASHING MIN. R 30 CIA SET IN BED OF SEALANT CONT. PERIMETER CONT. PERIMETER SEALANT 1 1/2"MTL STUDS 10'4" CN SEALANT - o 2 LAYERS OF 1 - T E CONTINUOUS SEALANT THICK CPVC - - STEEL COLUMN. RE: STRUCTURAL - STEEL COLUMN T.O.TRIM 8 m z w 0 0 B.O. CLERESTORY A - - - A - RE:STRUCTURAL 2 1/2"MTL.STUDS STAINLESS STEEL o ` 06 CONT.2X WOOD BUCKS -- 11' 0" SCREWS 8"MTL STUDS. RE:STRUCTURAL 1: 7/8"STUCCO FINISH OVER 3.4#SELF- DO 0 SHALL BE ATTACHED USING BRAKE METAL OVER ONE h FURRING GALVANIZED METAL LATH L.L _ _ BRAKE METAL OVER ONE 8 MTL STUDS. RE: HILTI KWIK PRO SELF LAYER HIGH DENSITY _ ADHERED MANUFACTURED N STRUCTURAL 1, OVER ONE LAYER HIGH DENSITY a Q W DRILLING SCREWS S WW N STONE VENEER LAYER HIGH DENSITY J POLYETHYLENE BARRIER OVER ONE Q U 14X20X2 3/4"PFH#4 WINGS @ POLYETHYLENE BARRIER ao _ ADHERED MANUFACTURED 1" „� LLj � OVER ONE LAYER BUTYL `� POLYETHYLENE BARRIER LAYER BUTYL RUBBER MEMBRANE ui 2.5#SELF-FURRING GALVANIZED OVER ONE LAYER BUTYL N o STONE VENEER LLJ 18"O.C. RUBBER MEMBRANE BARRIER - N 30 �) BARRIER OVER 5/8"EXTERIOR o z Z JIII "? 30 METAL LATH RUBBER MEMBRANE BARRIER Zv 2.5#SELF-FURRING GALVANIZED • Q Q X 4"CLEAR ANODIZED OVER 5/8"EXTERIOR GRADE N GRADE PLYWOOD SHEATHING c 0 /� TRIM.SEE ELEVATIONS ALUMINUM DOWNSPOUT PLYWOOD SHEATHING. BRAKE A7.0 MORTAR SCRATCH COAT AND OVER 5/8"EXTERIOR GRADE A7.0 METAL LATH j - ,,, 0 METAL FILLER ANGLE TO PLYWOOD SHEATHING. N 2 0 _ SETTING BED MORTAR SCRATCH COAT AND 9'0" o w W MATCH STOREFRONT.WRAP BRAKE METAL FILLER ANGLE SETTING BED I B.O.TRIM - a CO CONTINUOUS SEALANT 2"WIDE STAINLESS STEEL ONE LAYER HIGH-DENSITY TO MATCH STOREFRONT. L ONE LAYER HIGH-DENSITY I 1-1/2"MTL.STUDS SUBSTRATE AND TERMINATE 1"1" BRACKET WITH SMOOTH POLYETHYLENE BARRIER OVER WRAP SUBSTRATE AND I POLYETHYLENE BARRIER EXTEND ROOFING EDGES BEHIND STOREFRONT FRAME 5/8"EXTERIOR GRADE PLYWOOD TERMINATE BEHIND MEMBRANE UP SIDE WALL SHEATHING STOREFRONT FRAME OVER 5/8"EXTERIOR GRADE OF FLOA AND UNDER SILL(MIN.8" ' PLYWOOD SHEATHING VERTICAL ` G CN-RobertS Da ) PRE-CAST ADHERED MFD STONE OAa y signed ND 011P. ay C TUBE STEEL 6" 2' 3" 4" WATERTABLE/SILL(BEYOND) I 2 • ; _ Re SIN1EERa have e e c S. c� LOgERT$i;.- ooa0000ls o z s, RE:STRUCTURAL �4 1/2" 2' 4 1/2" 51/2" I p� �+ payontact 2'-7" 2'-10" I °d R Day"sm9fa Digital Scu nt as pin pi / \ U electronically signed s esyO�B foo�lagRo ert f his document are 21 aJs nd sealed annd the s t urerruyyM=e rei d 1g2 STOREFRONT SILL 20 RWC BRACKET DETAIL STOREFRONT 21 TOWER COLUMN DETAIL ABOVE WATERTABLE/SILL % 22 ,1 TOWER COLUMN DETAIL BELOW WATERTABLE/SILL A7.0 on Date 2021.07.2015 03-Oq BO' A7.0/ 1"=1'-Orr I 3'0" A7.0 3"=1'-0" A7•0 3"=1'-0" A7•0 1"=1'-0" �_ I T.O.STONE SILL 07/21/2021 PRECAST ADHERED MFDo N STEEL COLUMN L STONE WATERTABLE/SILL 0 7/8"STUCCO OVER ONE R30 BATT INSULATION STEEL COLUMN I N N N N N CEMENT BOARD LAP SIDING I RE:STRUCTURAL I m 0 0 0 0 0 8"METAL LAYER HIGH DENSITY �+ R30 BATT 6 RE:STRUCTURAL ADHERED MANUFACTURED STONE VENEER r N N N N N OVER ONE LAYER HIGH I 8"METAL 6 I ca AII FRAMING POLYETHYLENE BARRIER INSULATION o - N N o c� DENSITY POLYETHYLENE FRAMING CONT.2X P.T.WOOD BUCKS 2.5#SELF-FURRING GALVANIZED METAL LATH GWB AS OVER ONE LAYER BUTYL CONT.2X P.T.WOOD BUCKS I 0 0 BARRIER OVER ONE LAYER � ' -- o 0 0 0 0 ' R30 BATT 2'-3 1/2" 10" SHALL BE ATTACHED USING BUTYL RUBBER MEMBRANE I SCHEDULED RUBBER MEMBRANE SHALL BE ATTACHED USING - 2'-3 1/2" 10" a� GWB INSULATION 26 TYP HILTI KWIK PRO SELF DRILLING 3 BARRIER OVER 5/8" � , ����, 5/8" i 26 \ TYP I HILTI KWIK-PRO SELF DRILLING MORTAR SCRATCH COAT AND SETTING BED I 51/2" 41/2"I SCREWS S-WW 14X20X2 3/4"PFH EXTERIOR GRADE PLYWOOD R30 BATT EXTERIOR GRADE A9.0 SCREWS S-WW 14X20X2 3/4"PFH A9 0 4" 6" o BARRIER #4 WINGS @ 18"O.C. ONE LAYER HIGH DENSITY POLYETHYLENE SHEATHING INSULATION PLYWOOD SHEATHING SCHEDULED / #4 WINGS @ 18"O.C. I c z - BARRIER OVER ONE LAYER BUTYL RUBBER o ° O_ i INTERIOR EXTERIOR I MEMBRANE BARRIER OVER 5/8"EXTERIOR o_ w STARTER STRIP SEALANT - (2)16-GA STUDS (2)16 GA STUDS &(2) 16 GA RE:DOOR SCHEDULE B B I GRADE PLYWOOD SHEATHING > � w w w &(2) 16 GA 8"MTL STUDS 8"MTL STUDSX _ 0 U TRACKS TOP& FLASHING. EXTEND 4" TRACKS TOP& / FIBER CEMEN BOTTOM.RE: I 3 5/8"MTL __ -3-5/8"MTL I 22 ~ 0 j ~ UP WALL BEHIND LAP BOTTOM.RE: I fr > w Of CORNER TRIM 4/S5 ALUM THRESHOLD PER STUDS I A7.0 SIDING 4/S5 - I N I ADHERED MANUFACTURED STUDS � I HARDWARE SCHED. 1pli ADHERED MANUFACTURED a m CONTINUOUS I 2X P.T.WD STONE VENEER STONE VENEER I o BLOCKING SIM. I SEALANT N 2X P.T.WD A `�_ I A 2.5#SELF FURRING 2.5#SELF-FURRING I = Z L I 11 GALVANIZED METAL LATH SIM. GALVANIZED METAL LATH 1-1/2"MTL.STUDS BLOCKING I SHIM,AS REQ'D ° FIBER CEMENT SHIM,AS REQ'D L =___________ , - a°=• °. A7.0 MORTAR SCRATCH COAT AND 11 MORTAR SCRATCH COAT AND 13 - - A _ I 8"MTL. STUDS a R - SETTING BED q7 0 SETTING BED CORNE TRIM w n d g 0 CONT. �. ° PRE MOLDED EXPANSION BRAKE METAL OVER ONE LAYER \ ONE LAYER HIGH DENSITY I a A CONT. �; a ONE LAYER HIGH DENSITY BRAKE METAL OVER ONE LAYE I a a PERIMETER PERIMETER a° JOINT- HIGH DENSITY POLYETHYLENE POLYETHYLENE BARRIER OVER 5 Fo o N N 4 \ POLYETHYLENE BARRIER I o z BACKER ROD AND BACKER ROD AND SEALANT ° BARRIER OVER ONE LAYER BUTYL HIGH DENSITY POLYETHYLENE ONE LAYER BUTYL RUBBER A6.1 °' N c SEALANT FLOOR AS SCHEDULED OVER ONE LAYER BUTYL BARRIER OVER ONE LAYER I o U -- r w o SEALANT - SEALANT RUBBER MEMBRANE BARRIER \ RUBBER MEMBRANE BARRIER MEMBRANE BARRIER OVER 5/8" I >.o LU CD w a v ¢ N BUTYL RUBBER MEMBRANE g N, o �, � o a ¢ w C� N OVER 5/8"EXTERIOR GRADE OVER 5/8"EXTERIOR GRADE EXTERIOR GRADE PLYWOOD HOLLOW METAL FRAME HOLLOW METAL FRAME PLYWOOD SHEATHING.BRAKE BARRIER OVER 5/8"EXTERIOR SHEATHING U a o o U ° 5r, 5" METAL FILLER ANGLE TO MATCH PLYWOOD SHEATHING GRADE PLYWOOD SHEATHING. d STOREFRONT.WRAP SUBSTRATE 1 1l2"MTL STUDS BRAKE METAL FILLER ANGLE TO PRE-CAST ADHERED MFD STONE °; -° a MATCH STOREFRONT.WRAP WATERTABLE/SILL _ d 8"MTL STUD TRACK SUBSTRATE AND TERMINATE `' STOREFRONT FRAME BEHIND STOREFRONT FRAME 8"MTL STUD TRACK 4 • AND TERMINATE BEHIND ATO 25 HEAD EXTERIOR HM DOORS 26 JAMB EXTERIOR HM DOORS 27 SILL DETAIL 28 TOWER COLUMN DETAIL BELOW WATERTABLE/SILL 2g TOWER COLUMN DETAIL ABOVE WATERTABLE/SILL 30 TOWER LEG SECTION A7. 311=1'-0" A7. ill=1'-Orr A7.0 1"=1'-01, A7.0 1 1/2"=114" 07/26/2021 a N o u U cn o o A 5 A7.1 N O O k u 00 ­Wzl, CIS 3/8"ALUM. " . - 1"x 3"x 1/8"6063 T52 BRACKET WELDED 2 RECTANGULAR ALUM. TO LADDER TUBE A7.1 2-1/2"SERRATED ALUMINUM •�'�, TREAD(6005-T5) U PLAN LADDER 3 V� A7.1 3/4"=1'-01, CONCEALED LAG BOLTS WITH 7"MIN. SPLICE PLATE FLAT WASHERS (TYP.) LADDER BRACKET.WELD A C-0 PRE-FABRICATED TO UPRIGHT AT MAX 24" _ LU o MITRED CORNER O.C.VERTICAL SPACING ---------------T.O. PARAPET-� 2 ---------------- L Q - W T.O. PARAPET Z 2x2 22 6 A.F.F. WRAP TRIM ALUMINUM A 22'-6"A.F.F. Q FLUSH WITH LADDER RUNGS AT V-0" ANGLE 3-6" PROVIDE HOOK&CHAIN STUCCO O.C.VERTICAL I = GUARD BETWEEN PARAPET OPENING J SPACING o RAILING ON ROOF SIDE Q Z Ams 2 aSTUCCO J MOLD _ _ o w �� ALUMINUM GRATING - Q LU ALUMINUM BAR A7.1 � t 0- J LADDER PLATFORM J_ : END TRIM GRATING - 0 c� ¢ L1J ¢ TOP LANDING z � Q LADDER; t? Lu HOOK&CHAIN GUARD PLATFORM TOP Q , BETWEEN RAILS ON z Q - G� J o ALUMINUM ANGLE 2' 4" EQ I ROOF SIDE OF LANDING _j o 1" 1" 7/8"STUCCO FINISH OVER 3.4# LANDIN1. -___ I M FASTENED TO HORIZ. O EQ. N - SELF-FURRING GALVANIZED LADDER FRAME cC METAL LATH OVER ONE LAYER (BELOW) i A HOLD VERTICAL HIGH DENSITY POLYETHYLENE - M a BARRIER OVER ONE LAYER BUTYL PLATFORM FRAME ~ OF ROOF FOR FIELD A RUBBER MEMBRANE BARRIER - ADJUSTMENTS — — FOLD BRAKE METAL MTL GRATE PLATFORM OVER 5/8"EXTERIOR GRADE 2'- T.O.GRATE FRONT FLAP AROUND PLYWOOD SHEATHING.WRAP ,�8' 7"A.F.F. AND TOP FLAP OVER q STUCCO EDGE OF ROOF SAFETY CHAIN AT o o o o o / PARAPET. REAR OF LADDER w o o T.O. PLATE 0.G AT g LADDER ACCESS COPING L` J - Z ---�8'-1"A..F.F.- - - ------- 18'-7°A.F.F. 1'-8 1/8" `fl T.O. PLATE SKID �' i 8 18'-1"A.F.F. _ o 3 1/2"PLATE I A7.1 I OPP. 1 SEAM BRAKE METAL ON BOTH 4 LADDER PLAN @PLATFORM FRONT "1 SIDES OF PARAPET OPENING. (DO NOT CUT AND FOLD 3 VIEW OF PROVIDE ROOF WALK- 5"PLATE I 3�r a A BRAKE METAL BY HAND o A7.1 1"=1'-0" SKID WAY PAD BENEATH SKID` I 2 /2" WALL BRACKET - ) 3 ALUM.COPING CAP W/20 / NO TOP FASTENING GA.CLEAT AND THROUGH PARAPET CONCEALED SPLICE CAP m 1' 8 3/4" PLATE,COLOR:AS I o A o SCHEDULED SEE WALL BLOCKING I N a Itt, DETAIL FOR LADDER A 1'-6"MIN. MOUNTING I o MEMBRANEWRAP ROOFING DETAIL 00 BENEATH CLEAT I WALL BRACKET -— -— —-— o LO 8"METAL FRAMING co WHITE SINGLE PLY ui ROOFING MEMBRANE I mow�// 7/8"STUCCO FINISH OVER t EXTEND CONTINUOUS METAL FRAMING RUN I o m LL 3.4#SELF-FURRING t' UP AND UNDER q VERTICALLY @LADDER I 3 - O I PARAPET COPING SUPPORTS N GALVANIZED METAL LATH - t � yp. A7.1 i - ONE LAYER HIGH DENSITY I (n POLYETHYLENE BARRIER j I I WALL BRACKET OVER ONE LAYER BUTYL r —-—- -—- ------- RUBBER MEMBRANE "f BARRIER,WRAP OVER r�3 a Q PARAPET t I N I - O J 5/8"EXTERIOR GRADE 1 I o N PLYWOOD SHEATHING t IN LINE W/EACH LADDER BRACKET AT EACH LADDER BRACKET INSULATION AND � N s I. CONNECTION POINT, PROVIDE(3)2X6 CONNECTION POINT, PROVIDE 2"THICK INTERIOR WALL I m Z t ' WD STUDS BETWEEN(2)6"MTL WALL BY 02-1/2"SOLID ALUM. STAND-OFF W/ FINISH NOT SHOWN I � STUDS.RUN 2X6 FROM FIN. FLR.TO TOP HOLE FOR 01/2"LAG SCREW. SEAL ALL FOR CLARITYui I WALL BRACKET -— -— —-— - 06 Q j OF PARAPET WALL. FASTEN WD STUDS 00 AROUND BETWEEN ALUM.& PROVIDE(3)0.125"THICK SQUARE LLI N TOGETHER @ 6"O.C.VERT.W/16d STONE/THIN BRICK - ALUM. BUTT HINGES W/STAINLESS NAILS.ANCHOR THROUGH EACH MTL , 1 STEEL PIN,SPUN ON BOTH ENDS, Q Q U w STUD INTO WD STUDS I A7.1 _ �NO HOLES, FINISH SAME AS o w Lu I COVER.WELD LEAF TO LADDER 0 LLJ I "I SIDE-RAIL&OTHER LEAF TO a z Z J 0 01/2"X 5-1/2"STAINLESS 2"xl"LADDER RUNGS r � � ~ LADDER SIDE OF COVER PLATE Q STEEL LAG SCREW&S.S. (KNURLED)AT 1'0"O.C. I w H J g PARAPET CAP DETAIL @ LADDER OPENING WASHER VERTICAL SPACING 1 0 Lu WALL BRACKET a co A71 3"=1'-01, --—-—-—- - - 5 WALL BLOCKING DTL A7.1 1 112"=1'-0" LADDER BRACKETS: m OF F WELD HINGED ALUM. LOCKABLE 1/4"THICK WELD TO ' - \ �� `OA UPDRIGHTS AT MAX 24" I o SECURITY COVER. 1/4"THICK //q/ \�\ � I �I 6061-T6 ALUM. PLATE W/ G ERT Digitally signed S Da Da O.C.VERTICAL SPACING // LOB Pj= J�D0000016 0 2 s, SMOOTH EDGES. POWDER _ o=CUCI AND PETE � o / 1 ti ENGINEERS PLAN ea S COAT TO MATCH PARAPET / 0 I '^y��J V Re...Inelet This documart �� CAP COLOR / .0 �� ��,! Day usfi9 al Digital S g �. n pi WALL BRACKET / - - ofthisdocumentare �rwzsi e ________ _ _ _ / O / L C and sealed aad the s re�u�e ri d / U on any elgot�Qnic co i p Date:2tl2?gl' .2615: 56-CMO' 1/2"X 3-1/2"STAINLESS w 7"MIN. 30"CLR STAINLESS STEEL LAG I PRE-FABRICATED BOLT WITH FLAT I / \ / a .r - MITRED CORNERS , - z --% °' 07/21/2021 WASHER(TYP) I LADDER GUARD = N N POWDER COAT / N WRAP TRIM FLUSH WITH m / O THIN BRICK MATCH LADDER OLOR. o 0 0 0 0 I N ++ N N N N N WALL BRACKET N N O N I O O O O O PROVIDE ALUM. HINGED HASP 3 2-1/2"DIAM SOLID j ON LADDER SIDE OF COVER m — SEALANT / ALUM. STAND-OFF W/ I AND HOOK WELDED TO HOLE TO RECEIVE 1/2" I o o p DIA. LAG SCREW I N LADDER SIDERAIL TO RECEIVE c ., 0 PADLOCK. FABRICATE HASP � g r*� 1 -9 3/4 > N CD FROM SAME ALUM.AS HINGE. rn 0 w w w cn 16 GUARD - FABRICATE PADLOCK HOOK 16 0 ❑ `� FROM 1/4"ALUM. PLATE _ m ROOFING MEMBRANE 31�ti I WALL BRACKET — — ❑ E w w � w o m 1' 3" 1' 3" o o Z ¢ i o 7' I CLR. CLR. M REQUIRED CLEAR FOLD FRONT FACE OF m BRAKE METAL AROUND I WIDTH, EACH SIDE, FOR VERTICAL CLIMBING FOLD TOP FLAP DOWN 9/16"DIA. SPACE a IF s o N N OVER BRAKE METAL �I Z o, O N T.O.SLAB }o LU w N a Lu c� ¢ N SPLICE PLATE 0' 0"A.F.F. _ NEAREST PERMANECLEAR DISTANCE NT 0 o a _ p=° O N H O Q ¢ w (D N PROVIDE WALL CAP AT OBJECT ON CLIMBING SIDE OF', ` a LADDEMFDI'BRAKE G PER N LADDER DETAIL0 NOT A M CUT AN 3/8"THK.ALUM. METAL BY HAND. BRACKET A7 . 1 7 LADDER OPENING DETAIL 6 BRACKET DETAIL 2"' LADDER SECTION FIXED LADDER ELEVATION A7.1 / A7.1 3"=11-011 A7.1 j 314"=1'-0" 3/4"=1'-0"� / 07/26/2021 C a N o U U cn o o A "oG u".! CS oo U 00 '03 Cd REAR VESTIBULEv„ v' FLOOR: MAT OVER TERRAZZO V U U ------------- ----------- V� O DS DS DSO O O O DS 1 Ll O ® O O O ° Pi WATER SERVICE - ACRC MEN'S RESTROOM ELECTRICAL ROOM STAGING \ WOMEN S RESTROOM \ - FLOOR: EF-1 FLOOR:SEALED CONCRETE 17 ROOM FLOOR: FLOOR: EF-1 FLOOR:SEALED CONCRETE CO2 P2 FRPC P6 21 T1 20 A8.2 18 21 M1 A9.0 GT1 A9.0 CT3 ----- - 19 P6 P1 EF 1 GT1 ACRC FRPC CT3 EF-1 CD13 :001 W o E__ E o� --- -- ---- �-- --- 16 A8.2 14 WASH ROOM LU LU Q r - -- - -- -I IMG1 1 14 FLOOR:TERRAllO WALK-IN FREEZER � Q WC3 TYP CORNER A9.0 --------------- � O 15 FLOOR: INS MTL PNLS GT2 I _ I � FRPC � I GT2 I L � @ FRP I — J I I RETAIL WALK-IN I ISL1 - - -L FRPC T1 DS U) REFRIG. I STAINLESS STEEL J L O m Z II A W FLOOR:TERRAZZO - _ _ ° w Q 18 12 A8.2 10 z Q a ° z �-� z Q J A9.0 11 w o Q I w 11 O v CO w CT1 N cn I U cn LU Q FOOD SERVICE 6 U I r771 WALK-IN REFRIG. U' o o FLOOR:TERRAllO I FLOOR:TERRAZZO T1 8 A8.1 10 L T1 0 0 I II I I II I I 5 TYP CORNER - @ FOOD SERVI 26 FRPC SSTL 18 I_ 20 TILE J A9.0 q 4'-0" A9.0 A9.0 N CTI P1\/v ° ---- --------- 4 ACRC �\ ISL2 T1 DELIVERY VESTIBULE 3 A8.1 11 1 i CO CN > CT1 _ \ FLOOR:TERRAllO 21 I � 3 I 26 a W 2 J A o 3 I II I A9.0 I I I 24 A8.2 22r--- I 0 e FRPC I DS o I DN T1 23 I o A I o w w I --- --------------------------------------------------------- COFFEE O Q L - FLOOR:TERRAllO _ co - - ------------------------------------------------- -- ------ - z T1 L0 J J SELF SERVICE - - - oi5 I ' 'T W WALK-IN REFRIG. i v 00 FLOOR:VF1 OVER TERRAZZO Q 19 RETAIL AREA I I I I FLOOR:TERRAllO WC3 A9.0 ( N O L T1 VNR2 vJ 4A , III 7 _A8.1 9 � I � w II � o N J 1 m N L.L. w I I \ I o I 8 W z CV LL WC3 4B LO 0 N OO 06 ACRC J J V a L.L W W L-L o ASSOCIATE (:A8.1APRc i Q w _U Q U = FLOOR:TERRAllO I 1 ( �QO DS (w'� (_� MFRPC I R_ 8 < < ILLZ — J �. a z 0 20 ROLLER SHADE 2 ROLLER SHADES 12 ROLLER SHADES O� / FOR STAMPED CONCRETE, Q W z 0-1 NO O O l / SEE SHEET Al1.0 E Q LL w LU LL w 22 A8.3 19 H FOR OUTDOOR SEATING a LAYOUT,SEE SHEET EQ1 N D DS S N 21 II � Fto G.C.TO PROVIDE AND INSTALL �c�G-�F•... SHADES AT ALL STOREFRONT GLAZING BELOW IV-0"AS PER G Digitally signed by R Day gERT Robert S Da Q ��,t7�M��� D0000016 0 2 9, Q 15 SPECS. MOUNT ON INSIDE OF N LO_ bocuHACIANDPETE C ENGIN€ERS PLANK C4 S OPENING. RE: DETAIL 9/A3.1 p.� • ' Reason:Thsdocument �� U) (TYP.) f� J S [���/Day uoq;g a signed an afeQ o ert 06 Day us g a Digital Sg n pi of this document are Wer2l�si e 7 A8.3 14 J U t C and sealed aad the s re8u e n d �o Q 16 NOTE:ROLLER SHADE FASCIA I on any ele�otrQnic co i p T on a 2021.tr m 15: :40-C�00' M1 COLOR TO MATCH STORE --- - 2 FRONT(TYP.) OFFICE Z 07/21/2021 FLOOR:TERRAllO ACRC 4 A8.3 1 FRPC P1 T1 o � N N N N N ———— —————— ———— — ———— —- N N N N N (2)ROLLER SHADES (2)ROLLER SHADES (2)ROLLER SHADES ~ 3 LINE OF PORCH G N N o N o L - L L L L L x OVERHANG ABOVE o 0 0 0 0 DS DS a D I K m t I c z y L--------------------------------------------------------- c O ci 0 0 w W w G.C.TO PROVIDE AND INSTALL °' °' N p SHADES AT ALL STOREFRONT N m w GLAZING BELOW 1 V-0"AS PER SPECS.MOUNT ON INSIDE OF s 0- a m a OPENING. RE: DETAIL 9/A3.1 6 (TYP.) A z Q rD NOTE: ROLLER SHADE FASCIA lt n m COLOR TO MATCH STORE r FRONT(TYP.) FINISHED FLOOR PLAN ¢ 8 o oaZ �, 0 0 L t5 U oUj Z Y p o O C14 H O Q Q W (D N U— w Q d' 2 ' d U A8 . 0 07/26/2021 GWB TO COVER INSTALL WINDOW SHADES AT "Thank You"BANNER SIGN EXIT SIGN SPANDREL WINDOW. STOREFRONT. (TYP) Q, )1,2 "Thank You"BANNER SIGN y 10 A7.oWT-1At4 OP1 WT 1 P1 P1 WT-1 WT 1 A �N b � V P1 Thardcvoar P1 P1k U -------- ---------- -------- -- ---------- 0 Cc ----------- - -------- -------- - ----------- ----------- P1 WT-1 WT-1 ACRC p � O o ----------- ----------- WT_1 IN V1 A-I fZl w ^ � ACRC II I I II I � FA HORN/STROBEII I I II I I I I -- ---- ---------- WT-1 ACRC I I I FA HORN/STROBE I I I I I I ACRC FASA = / N ------- � � ---------- ----------- 16 L---------- BOOR ISL1 = �� TACTILE EXIT FA PUL STATION O SIGN (TYP.) 9 5/8" 3'-0 3/8" � P6 OPEN TO FA PULL STATION _� FRAME RETAIL CIS QUAD � ALUM. PANEL OVER o v A = A BEYOND 0 4 �/ �j U` SPANDRAL BY / ail ACRC RECPT Ago �/ // �/ // STOREFRONT r, / MANUFACTURER, (2)2x6 / y SEE DETAIL 16/A9.0. �, BLOCKING Q] DUPLEX DUPLEX ACRC DUPLEX ACRC ACRC ACRC RB1 U0 RECPT RB1 RECPT. RB1 RECPT RB1 RB1 RB1 RB1 w RB1 1 CIO INTERIOR RETAIL ELEVATION 25 v A9.0 2 ALCOVE ELEV. 3 ALCOVE ELEV. 4 ALCOVE ELEV. 11 ALCOVE ELEV. \� A8.1 1/4"=1'-0" A8.1 1/4"=1'-0.. A8.1 1/4"=1'-0" A8.1 1/4"=1'-01, A8.1 114"=1'-01, ` �1 U GENERAL NOTES V DASHED LINES 6 1. USE RB1 BASE AT ALL CABINETRY. "BEER COOLER"SIGN INDICATE BLOCKING A9.1 2. PROVIDE SCHLUTER STRIPS AT TILED CORNERS AND AS NOTED ON THE PLANS&ELEVATIONS 7 FOR FOLLET. PER SPECIFICATIONS. 3. ALL HALF ROUND WOOD TRIM SHALL BE PAINTED P-1, U.N.O. \ WC3 GT2 WC3 P1 P1 4. MITER CUT ALL TRIM-NO BUTT JOINTS. P7 PERP. 5. PROVIDE CORNER COVE BASE AT ALL CORNERS. 5 6. NO FINGER JOINTED WOOD TRIM. P7 .0.SOFFI GT2 A9.0 7. REFERENCE SHEET E01 FOR SPECIFIC EQUIPMENT IDENTIFIED HERE-IN. WC3 T.O.SOFFIT P7 - P1 PERP. FJ� IRE ALARM P7 - �` WT 1 GT2 _ T.O.SOFFIT P1 HORN/STROBE FRPC T.O.SOFFI - -- _ B.O. SOFFIT _I SSTL cD \ / CT1 CT1 CT1 FRPC C.I N CT1 CT1 \ / ACRS RETURN WALL SELF SERVE BEVERAGE \ / INTERIOR STOREFRONT GLAZING LEGEND 27 - v / /' ACRC � ' � AREA = m � � DOOR RTU A9.0 p A / // B32 12"X18" ® 0 IMG1 -_--= o OPEN TO BACK OF \ \ / OT 1/4"TEMPERED GLASS SENSORS "r n _ ACCESS 2'-0 2 5 A m M I FOOD SERVICE RE: MECH TRIM KIT QA - / OPEN TO FOOD I / \ il SERVICE, PANEL W o ALUMINUM PANEL BY STOREFRONT MANUFACTURER OVER __ _ O7 IF Y_ / \ / \ I / � \ SPANDREL. RETAIL SIDE ONLY.SEE 16/A9.0. o v B24 CL Q N / \ // \\ NOTE: REFERENCE EXTERIOR ELEVATIONS FOR W Z / \ EXTERIOR GLAZING SCHEDULE � Q RB1 ISL1 RB5 RB5 P8 17 RB1 4 SPECIAL PURPOS RB3 G4 J RB1 FRAME RECPT. A9.0// A9.1 SCHLUTER STRIP,TYP ALL 4A INTERIOR RETAIL ELEVATION - FINISHES TILED CORNERS. RE:20/A9 5 FOOD SEVICE ELEVATION B30.2 1.NOT ALL TILE, GROUT AND SILICONE SEALANT FOR FRP AND TILED AREAS TO BE SUPPLIED BY WAWA m Z A8.1 1/4"=1'.0" A8.1 1/4"=1'-0" VENDOR AND INSTALLED BY GC.ALL MASTIC AND THIN SET MORTAR TO BE SUPPLIED AND INSTALLED LU CENTERLINE OF ICE/FREESTYLE BY GC. LU � MACHINE(TYP.) 2. ALL FINISHES INSTALLED BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. z W Q wQoQ LIT SIGN (6)SOFFIT HUNG DATA AND RECEPT.TYP(6) N MONITORS SEE DETAIL. SEE DETAIL 3/A9.1 ® _ �DIGITAL H DIGITAL E DIGITAL �DIGITAL H DIGITAL DIGITAL A MONITOR MONITOR MONITOR MONITOR MONITOR MONITOR DUPLEX RECPT STAINLESS STEEL FIRE ALARM/ o END CAP,TYP. HORN STROBE o SELF SERVE BEVERAGE _ DATA AREA -=- PROVIDED BY RECPT CABINETRY MFR ACRS \ / ❑ L� ❑ 43"DIGITAL vv //� / o CUP C20 TACTILE EXIT MONITOR 11 B1.2 \ / / -DOOR DISPENSER w SIGN(TYP.) - - -I \OPEN TO FOOD O O E _=EQ 'v SERVICE ❑ OPEN O b SPECIAL PURP 3 O O O RECEPT o _ IIIIIIIIIIIIIII Ir / \ ❑ ❑ ❑ � ° �� FRAME / \\ U 0 0 C28 C28 MW17.1� C21 C23 MONITOR TO HAVE 1 B19 B9.1 B44 B19 RB5 B21 F5 0 C22 C22 5 CLEARANCE ON ALL F5 PURPSPECIAL F5 619 A C) A9.1 I S B21 B21 00 DUPLEX a (o 4B INTERIOR RETAIL ELEVATION - EQUIPMENT RECEPT 6 FOOD SERVICE ELEVATION EQ EQ 6'-10 1/8" O DASHED LINES INDICATE PROVIDE 1/4"HARDIE DASHED LINES INDICATE BACKLIT LOGO SIGN. 2X6 BLOCKING BACKER BOARD OVER 2X8 BLOCKING FILLER PANEL BY REF. A U) SEE DETAIL 11/A9.0. GWB WHERE INTEROR CO.TO MATCH z STONE OCCURS. III ADJACENT FINISHES o 0 c 0 N WC3 WC3 Q WC1 A WC3 PERP. � WC3 _ P7 w --- - o TnTLF D ° T.O.SOFFIT DUPLEX RECPT. oo $ m o � o0 0o WT-1 P7 RE. 12/A9.0 LL z _ ACRC FOR CT1 m w 47 ACRC p GT2 P7 MOUNTING a T.O.SOFFI HEIGHTS � � W O ❑= a Q W - INTERIOR STONE ADHERED TO Q U GWB PER MFR'S REQUIREMENTS. W5 R3 ' ACRC ACRC W DOOR / / / / / / Q W LU LU DOOR � � Q W � Z i� I ti O LU 0 � � o � w ACRS SOAP AND DUPLEX DOOR P6 N P6 PAPER TOWEL RECPT. / FRAME DISPENSER. FRAME e Nil 1W6 b OF Ftp� a Digitally signed b R D RB1 OUTLINE OF CIGARETTE P8 RB1 ISL1 DUPLEX ,� G g v g v AND TOBACCO CASES. RECPT. LpgERT _ � D0000016 0 2 9, RB3 RB5 RoberlS Da FRAME RB5V_w� o=cur IANDPETE NA I C RE: 1/EQ1. y ENGINEERS PLANIk Ca S Reason:This document 6e electrogqicslly signed pn aaJJee,,QQt�o art 06 �Rbb 'S ��Day usfig sally S g �!�rifitd pi .� of this document are �der*l s 7 INTERIOR RETAIL ELEVATION g FOOD SERVICE ELEVATION L`O C and sealed a.d the s' re ui2e ri d U on any ele�ot�Qnic co p Date:2021.1tl.26 15: :45-0w0' d a a 2 07/21/2021 WINDOW SHADES 0 AT STOREFRONT. N N N N N s y 0 0 0 0 0 - DASHED LINES WT-1 ++ N N N N N A2.0 INDICATE(2)2X6 m p BLOCKING It 0 0 0 0 I� CO M O � N N O N WC3 WC3 ` P 1 l a� EQ EQ / �/ m PERP. / \/ 0 _ _ � WC3 � c O_ c Fb o - P1 m y E w F_ w O T6oan<Yoat d y N (n O U P1 WT 1 - ------- - --- ----- -------- CT1 G - w - II 0 w > w N II IIII I II / B42.2 G2 04 W6 ACRC P1 DUPLEX V3 O � z Q DUPLEX O WALL BEHIND ----- ---------- ---------- -------- RECPT. O RECPT. / EQUIPMENT '4 / / B12.2 =N _ O TACTILE EXIT � m 3 SIGN(TYP.) a m a o P1 ACRC _ -_=- ¢$ p o Op a Z DOOR \ C3.4 C3.3 =LL ~ o w ALCOVE P6 = DATA OT ' LU CD o � W o �' ¢ w aU' RECPT. o 5 a N o U FRAME B28.2 ACRC RB1 RB1 RB1 ACRC ACRC 25 RB5 RB1 A9.0 RB1 A8 . g INTERIOR RETAIL ELEVATION p FOOD SERVICE ELEVATION A8.1 1/4"=1'-0" 07/26/2021 W In. N CD I o 0 N o U cn o o .y TILE TYP FOR ALL WALLS. PROVIDE FIELD TILE(CT3) �10 w � �% I RE:TILE PATTERN BEHIND MIRROR. ENSURE �o "0 10 SCHEDULE, DETAIL 26/A8.1 THAT MIRROR COMPLETELY N g � �? 0 CONCEALS FIELD TILE GT1 FA HORN/STROBE �4 r- r- o p N� Oo lk' U CD 7_1 11 g 8 8 3" 3"� / 12 le i N V1� a W. w 14 8 1' 6" 4' 6 1/2" 4' 6" 1' 6" 1'-7" GL 4'-41/2" GL 3'-8" q1'-41/2" I 14 -I 1 \ 4 2" I I I I 4 2" \ \ ACRS rA 6.. . 3 I / p .. 3 4 \ DOOR � 0 ` I 13 3 ®� 6 13 I�� I . 0 5 13 0 - P8 II 13 ® 1 � ® 13 � i ® � 2 I 1 I ` 15 0 9 1 i 9 w 13 i- -a- - -- - 7� - 7 16 7 / to 6 , REAR VESTIBULE 6 _ 2 2 / b i . ' T CLR FLR 15 F7 GENERAL NOTES _" 4 7A 3 _ �, SPACE S 2 .� i 4 7A 3� i 17 � i "' 30"X 48" 9 9 CLR FLR I I ; i to 14 SPACE I I 2 7 14 8'-4" i 1 � 2'-61/2" 1.ALL DIMENSIONS SHALL BE TO FACE OF FINISH U.N.O. PL 1 29 2 60"X 56"1 1 CLR FLR I I i A8.2 ` mo w SPACE 1 5 9 A8.3 6 CLR FLR CLR FLR i 2. INSTALL A BEAD OF CLEAR SILICONE AROUND ALL TOILET SENSORS „ i i S X 48" SPACE 'SPACE i AND ESCUTCHEON RINGS. V ___________ cn �' 41/4_��_____16 4 -63/4 8 ( , _ ? 6o"X56 3o,x48'_--- 1 16 BARRIER FREE NOTES 2 WOMEN'S RESTROOM ELEV. 3 WOMEN'S RESTROOM ELEV. 4 WOMEN'S RESTROOM ELEV. 5 WOMEN'S RESTROOM ELEV. \� 2 8 BELOW- A8.2 114"=1'-0" A8.2 1/4"=1'-01, A8.2 114"=1'-01, A8.2 1/4"=1'-0" ` �1 BELOW 16 --- 10 10 MEWS RESTROOM - 8 10 TOILET ROOM TO COMPLY WITH ALL BARRIER FREE U _ DESIGN REQUIREMENTS INCLUDING BUT NOT LIMITED T0: I'll \ �-•; � 1 CLR FLR i /ice �3 A8.2 5- - i � 5 \\ 'CLR FLR v SPACE i / 5 \ 12 12 /6 \ 'SPACEL A. GRAB BARS :TOP OF GRIPPING SURFACES ON GRAB BARS WILL 30"X 48"i / \ 4 \ i30"X 48" BE 33"-36"ABOVE FLOOR AS SPECIFIED ON SHEET AC1 i I � I I li i I I 10 7 I A8.2 9 O° Irw B. MIRROR: (1)24 X 36", BOTTOM AT 40"A.F.F. MAX.AT EACH I '1 4 3 BELOW 7 LO / LAVATORY. \ // 13 A8.3 11 \8 16 // C. LAVATORY: RIM HT.34"MAX.A.F.F; BOTTOM OF APRON 27"MIN. WON�fN S RESTROOM / I \ BELOW / 4 i � i A.F.F. LEVER HANDLES ON FAUCETS, IF APPLICABLE. INSULATE HOT11 FA HORN/STROBE PROVIDE FIELD TILE(CT3) WATER SUPPLY AND DRAIN PIPES.ALL PIPES BELOW LAVATORIES - - -- - ��� - 15 � 12 15 1 �� 3 - -L - TILE TYPICAL FOR ALL WALLS BEHIND MIRROR. ENSURE ll 21 _- � - - - - ---21 WILL BE INSULATED OR CONFIGURED TO PROTECT AGAINST THAT MIRROR COMPLETELY CONTACT IN ACCORDANCE TO SECTION 606.5 FBCA SEE TILE PATTERN SCHEDULE DETAIL 26/A8.1 CONCEALS FIELD TILE D. DOOR:36"WIDE WITH PUSH/PULL HARDWARE AND SIGNAGE. N 8 1 -3 5'-7 5'-41/2" 1'-3" g a 12 3" 3" E. URINAL: MAXIMUM CLEARANCE TO RIM OF URINAL IS 17"AS ------_----- 11 SPECIFIED ON SHEET AC1. 14 14 --2 ACRS / 4 - - -F. WATER CLOSET: RIM TOP AT 17"-19"A.F.F.AUTOMATIC FLUSH 13 1 O I DOOR / 13 CONTROL 1 `� 1 1 I M 4 6 1 3 PS 0 6 3 O I 3 G. TOILET PAPER DISPENSER:CENTERLINE OF TOILET PAPER 1I 4FRAME 15 to� 15 r DISPENSER WILL BE 7"-9"FROM THE FRONT OF WATER CLOSET 2 y C-0 O I1:1 \ 7 Y m H. PAPER TOWEL&OTHER DISPENSERS :48"MAX HT A.F.F.TO LINE -- - �-- 7A 1 \ 16 1 14 � 7 OF OPERATION. 9p�[ 11-1 , - \ I �, � I I W 4 _41 . 11�1 z. RE:SHEET AC1 FOR ACCESSIBILITY REQUIREMENTS PL 1 S-2 29 0 j A8.2 � J J. BARRIER-FREE: PROIVE 32"MIN.CLEAR OPENING AND SELF- S-2 PL-1 � CLOSING DOORS FOR ACCESSIBLE STALLS. J U) Q z 1 PUBLIC RESTROOM ACCESSORIES DIAGRAM A 6 MEN'S RESTROOM ELEV. 7 MEN'S RESTROOM ELEV. g MEN'S RESTROOM ELEV. g MEN'S RESTROOM ELEV. Q � Uj A8.2 114"=1'-0" A8.2 114"=1'-0" A8.2 114"=1'-0" z � LU Q N � DASHED LINE INDICATES 1/2"DUROCK AT BASE OF WALL TO 48"HEIGHT AND 1/2"PLYWOOD ABOVE DUROCK BEHIND WALL MTD SHELVES. . .. ... .. .. METRO WIRE AP AND PAPER SO \ / ,.. _ A FRPC...HORN STROBE _ _ 0 . . . . . .. . FRP : : FRP \ / D2 FRPC SHELVING SYSTEM ... T WEL. ... ... ::: . . .. ... . .. .. ... ... . . .. .. . . .. . . ... . . .. ... . . .. ... ... . . ... ... . ... .. ... ... . . ... . .......... . .. . . . _ . . ._ .. ._. 0 � O N FRPC1.TYP. FRPC FRPC FRP RE.Al2/A9.0 FOR FRPC - - - - C D111.. . .. . . . .. . -d ISL2 .-... ... . :.::... .. .. ... ... ... ... ... ... ... ... ._ ... ... ... . . ... . . . ... .. ... ... ... ... ... ... ... ... ..::. _. ... c� D11 _ _. . . _ .. _ _ .. . . . . . . ._ .. _. _ .. MOUNTING HEIGHT S D2 D11 A FRPC ..... . . . . .. . . / . . ... . . . _ ... -. ... ... ... . . . ... ... .. ... ... ... ... . . . ... ... ... ... ._ _ ... ... ... . . .. . . . FRPC FRPC _ _. ... . . . _ . . . . . . . . . \ / D2 01.\ / FRPC .. . . . .. . ... . . . .. _. _. ... .. 0\ 1.1. 1. .N / _ . . . / o _ O � - A _ . . . _ . . . . . . _. ... ... . _ .. . . . _. . i� _ . ... .. . . . . . . . . . .. ... .. ... . . . . . . ... . . . . .. ........ . ..... . . . .. ..... .. .. . . ._. . . . .. . . . . . _ _. . . . . . .. . ... .. ... ... _. _ . ... .. _. . . _ .. . _. ... . . . . .. .. .1. \ / .. .. . . . . . . .. .. . . . . .. . . .. . . . . . .. ... . . .. . . . . . ... ... .. ... . . . . . . ... . . . . .. ... . ..... . ._ . .... ..... .. .. . . ._. v \ / . . . .. . . . _ . .. . . . . . . . .. ... .. ... ... . . _ ... .. ... . . . . .. .. ... _ .. ... ... . . ... ... .. . ... . . ... .. . ... .. J_. ... ... ... ... ... ... ... .. ... ... ... . ... ... ... ... ... ... ... ... ... .. ... ... ... ... ... ... .. ... ... ... ... .. ... ... ......... ..............I...1...1.1.I. -..............I. I.1.1.I .... c � OPEN TO FOOD a .. . . . . . . _ _. . _. . . . . . _._.. . . . _.... . ... . . ._ . _...._...... .. . . . . . . . . _. . . _ _ .. . _. _ _ . . .. _. . . _ _ . . . . . . . _ SERVICE \ / 1.1. 1. 3 ii _ .. ._ . . . . . . . .. . . . _. . . . . . . . . . . . _. . . . . _ . . . . . . . . . _ . _...... .. _ _ . . 3 ----- -- - PEN _ . . . . . . . _ .. . .. . . . . . . _. ._ 1._. . . . _ . . . . . . . ._ _ . _...... .. _ _ . .. 0 z H . . . . _. . . . .1. . .. . . ... . . _. . . . .. ... ... : _ _. . ... . . . . . . . .. _ . . . . . . . . _ 1. 1. 1. 0o PEN TO F D ACRS 0 00 \ 1-1-1-1-1-1-1-1- F1.5 1. D2 I - - - . .. . . . . . ... . ... . . . . . ... .. . . .. _ .. 01. 1. _ SERVICE _ .. ... ... . 1. I _ . _ _ . .. ch \ F �j I- - - - - I I - - - - - - - - - / \ - - I � � , � .. ..- ___ - .' '.. . . ._ .. ... ... .. ... . . . . ... ... _. _ ... ... ... . . ... _. . ... ... .. .. ... .. ... ... _ . . ... .. ... .. ._ .. % e 1. ­­. 11-L.-, - 1. I. Y - I - - - - � � \ _. ... _. ... . . . ... ... ... ... _. ... ... . ... ._ _. ... ... ... ... .. ... ... . .._..... . . ....................... . ........................... .... _. - .. ... .. .. ... .. .. ... - .. o � ..1 .1. 1.I _. . ... ... _. ... ... ... ... .. ... ... I.. ... ... .I. .. ., _. ... ... ... ... .. ... _. ... .. I ­11-1-1-1-1-1-1-1-1-1 ­ ... ... ... ... _. . .. ... .I. .I. .I ... ... _. I.. ... .I. .1. .. ... ... ... ... ... ... .. ... _. I.. ... .I. .I. . ... ., ..I . ... ... . . 1... ... . ... ._ _. ... .. I. O / \ / \ _ . ... .. . . . . . . _ _ .. . . . . . .. .. _ .. . . . . . ._ _ ... . . . . . . ... . . . .. ......... . ..... . . . . . .... ...... .. . . . . . . . . . . . . . / \ _ _. . . . . . . w / \ . . . . . . _ .. ... . . . . . .. ... ... . . _ .. . . . _ _ _ 0 o . 1- .. . _ .. ... . . . . _ .. . . . ._ .. _ .. ... ... . . ... ... .. . . . ._ _ FRAME 7 ��� ���I - ; - - � / - I � I - I 1� ��� - - I � - - - - � I - - � - - - - - I I - - \ _ _ . . / \ _ _ _ _ ..................... . - _ _. . _. .. _ _ t 1 . n d O RB3 2x12 BLOCKING RB3 I RB3 RB3 F5 RB3 RB3 F5 RB3 RB3 RB3 RB3 BETWEEN STUDS RB1 RB3 B19 B19 B21 B21 ` co U-) m 4t 10 WASHROOM ELEV. 11 WASHROOM ELEV. 12 WASHROOM ELEV. 13 BACKROOM ELEV. 14 BACKROOM ELEV. 15 BACKROOM ELEV. 16 BACKROOM ELEV. i �W// A8.2 114"=1'-0" A8.2 / 1/4"=1'-0" A8.2 1/4"=1'-0" A8.2 1/4"=1'-0" A8.2 1/4"=1'-0" A8.2 1/4"=1'-01, A8.2 1/4"=1'-0" - LL 0 16 MOUNT BUG LIGHT DIRECTLY DUPLEX SURGE TANK ON FRP- - CSR UNIT A U OVER RECPT. SO POWER RECPT. WRAPPED SHELF RE: PLUMBING SODA CHASE SODA CHASE z AIR CURTAIN RE: DETAIL 8/A9.0 RE:9/A2.0 : / .0 AIR CURTAIN o � 0 CORD IS CONCEALED DUPLEX RE: MECH AIR CURTAIN RE: MECH RE: ELECTRICAL - RE:MECH. RECPT. FRPC SURGE TANK ON . z . O FRP-WRAPPED SHELF _ � N S FRPC . Q RE. DETAIL 8/A9.0 . . . . . . . . . . . . . .... - .... :. ..: . 2 .: FRPC FRPC . . . . . . . . . .. WATER � - - - - � - - - - - - - - 1. - - I ... ... ...I - - - - - - - I - - - - - I-/ - - - - - - - - � - - - - - - - - - - - - - - - 1� ��, - - __,,__%�HEATER FRPC FRPC ISL2 �I - - F w DISCONNECT \ CO2 ALARM AND AIR CURTAIN $ m J WARNING SIGN BY _ _ _ . FRPC _ QUAD. RECPT. z TRASH \ . . :::.. . . . . � - FRPC . . . . w FRP CO2SYSEM VENDOR MOP RACK ... . BA C \ _ ... P6 G / O _ \ O L0 ALARM \ OCCUPANCY 06 �/ :.--... -- oo--.:. HOLDERS . . . . _ _ . . . . ... DR&FIRM J STROBE oo.: .. ._ \ DATA RECPT. . . . . . _ __ OD LL 00o P6 ACRC SENSOR _ a LL DR&FIRM DOOR = = _ 0 DUPLEX: / o .... o \ a W OPEN E BNB SHELF _ . . . .. __ Q _ ALARM PULL 0 Q U nn// - RECPT. A 00 _ W L.1_ / P6 - STATION LU �, FA PULL :: / P6 - v O W - \ STATION C .. - - - - - - - - - - - - - - - - - I - - - I I / DR&FIRM FRAME \ FIRE - - o Q z - J w. ... / EXSTINGUISHER : :' / Q . W / . . z - MOP SINK o \ / \ D2 / - ~ RB3 _ \ / RB3 / \ CO2 ALARM AND 1.1. F z w 0 LL w F__ . . 11 L I , , "' WARNING SIGN / d p w BY CO2 SYSEM � CL `�' WATER HEATER ON 30"x30"x4"H A RB3 OCC. WATER HEATER ON 30"x30"x4"H RB3 VENDOR D1 D2 0 PRE FAB CONCRETE PAD RB3 SENSOR PRE FAB CONCRETE PAD RB1 RB3 RB3 b A �pF F. 0- G Digitally signed by R Day Lp13 _�t7vM-��R�°p00000;6 �. --- ---- O=CUHACI AND PETE IJ� -II-II C 17 STAGING ELEV. 18 STAGING ELEV. 19 STAGING ELEV. 20 STAGING ELEV. 21 DELIVERY VESTIBULE 22 DELIVERY VESTIBULE 23 DELIVERY VESTIBULE 24 DELIVERY VESTIBULE ENGWEERSd,,,,,E S d � Reason This document �r� aa electrogqically signed 4n aJe,Qt�o art A8.2 114"=1'-0" A8.2 114"=1'-0" A8.2 _ A8.2 114"=1'-0" A8.2 114"=1'0" A8.2 114"=1'-0" A8.2 114"=1'-0" A8.2 114"=1'-0" R"y Day usfi9 a Digital S g 1!�rifitd pi 1/4 1-0 of this comment re �der�ksi e t C and sealed a.d the s' re& ri d U on any ele�ot�Qnic co p Date:2021.1tl.26 15: :09-CWO' a m m n RESTROOM ACCESSORIES SCHEDULE f 07121/2021 z # ITEM MANUFACTURER MODEL# REMARKS SUPPLIED BY N 1/2"M.R. GWB iu o 0 0 0 0 2 2 N N N N N I 1 ELECTRONIC HAND DRYER EXCEL DRYER INC. XLERATOR XL-C CHROME ELECTRONIC HAND DRYER WITH RECESSED KIT HJC m ti M (M ao •,'_ I SCHLUTER JOLLY 2 T.P.HOLDER - - 7"MIN-9"MAX IN FRONT OF WC.OUTLET 19"A.F.F. HJC 2 qt N N o N ANODIZED ALUMINUM P6 I FOR 3/8"TILE 3 SOAP DISPENSER TORK 571608 BLACK TOUCHLESS ELECTRONIC SOAP DISPENSER-BATTERY OPERATED HJC � a) o 0 0 0 0 oIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII FIELD TILE PER 4 MIRROR BRADLEY 780-2436 24"X 36"MIRROR WITH S.S. FRAME IN SATIN FINISH. HJC -2 0 a ELEVATIONS RECESSED HAND DRYER 5 COAT HOOK BOBRICK B-233 STAINLESS STEEL WITH SATIN FINISH MOUNT HJC o = 0 = WALL TILE,CT3 6 42"GRAB BAR BRADLEY 8120-00142 STAINLESS STEEL WITH SATIN FINISH,BOTH RAILS 42"IN LENGTH HJC V) o p v } PROVIDE DUROCK UP TO o A& � M I � COUNTERTOP .11 7 LAV CABINET CABINET - CABINET BELOW LAVATORY SUPPLIED AND INSTALLED BY CABINET VENDOR.COORDINATED CABINET 16 o 0 0 4'-0"ALL WALLS OF TO BE ONE SEALANT A BY GC. fn •0 L o w LU W G RESTROOMS N I 2 6 XPIECE Ill-8a 7A LAV SHIELD TRUEBRO 2018-AS L FOR AMERICAN STANDARD LUCERNE LAVATORY HJC °�' N p r% I S T L R: W a i o - I. - "' M ACCENT TILE PER PROVIDE CORIAN 8"MIN. D E FOR 8 TOILET PARTITION SCRANTON SHALE SOLID PLASTIC PARTITIONS(NO SITE LINES)W/S.S.PRIVACY SLATS,AND SELF-CLOSING HJC t g N m n- 3/8"TILE q DOORS.PROVIDE PULLS ON BOTH SIDES OF ADA STALL DOOR. � w w w CARBON DIOXIDE GAS --- ------------- ----- I ELEVATIONS FINISHED END _ ''� I AND 1/2"THICK CORIAN PANEL 9 NAPKIN DISPOSAL UNIT BRADLEY 4722-15 STAINLESS STEEL WITH SATIN FINISH.WOMEN'S ROOM ONLY. HJC 116 - a 00 a- ,0-1, VENTILATE THIS AREA TILE FINISH BACKSPLASH AT TO MATCH VANITY GLUED 10 WALL BRACKET BRADLEY - MOUNT ON TOP RAIL WHERE PARTITIONS MEET WALL HJC t z = BEFORE ENTERING. - WALLS TO DUROCK 12 ECONOMIZER DISPENSER MICROBURST 9000 401375 2 UNITS PER RESTROOM, 1 NEAR DOOR AND 1 OPPOSITE.TOP 2"MIN FROM CEILING WAWA Q o M SCHLUTER JOLLY N A hi carbon dioxide as(CO,) A 13 TOILET SEAT COVER DISP. - - ONE PER STALL HJC high g o 0 "v I ANODIZED ALUMINUM OFFSET TAILPIECE C U 0 LY concentration in this area can FOR 3/8"TILE RE:PLUMBING 0 Z I OR 14 18"GRAB BAR BRADLEY 8120-00118 STAINLESS STEEL FINISH.MOUNT RAIL VERTICALLY. HJC -3° 'v = 1'TO 1-1/2" r cause suffocation. o N 3/8"TILE 15 WASTE RECEPT. BOBRICK B-3644 RECESSED INTO WALL-4"WALL RECESS REQUIRED,4"PROTRUDING BIN HJC a PARTITION - COUNTERTOP Lo = a $ a V LEG AND CABINET BY 1/4"DUROCK CEMENT BRD 16 SOLID SURFACE PANEL DUPONT CORIAN COLOR:COTTAGE LANE 1/2 THICK, 14-3/4 WIDE X 20 HIGH PANEL MOUNTED 6 A.F.F.,LOCATED BELOW HAND CABINET m o o In WIDTH 8" _ 6"MIN. , DRYER.SEE DETAIL 311A8.1. °' ........................................................ .................................................................................. I N 6 6 .......................................: - _ o oa Z o CABINETRY MFR. 1/2 DUROCK CEMENT BRD „ `" w ............................................. :.::,................................................. - 1/4 DUROCK CEMENT o 0 I BOARD �' I 17 DOOR STOP(PARTITION) SCRANTON - SUPPLIED BY TOILET PARTITION MANUFACTURER.LOCATE AT BOTTOM OUTSIDE CORNERS HJC = w Z Y EPDXY FLOORING W/ OF DOOR. 0 0 o " � o ¢ w N EF 1 1/2"DUROCK CEMENT - REMOVEABLE INTEGRAL COVE "' a o c = NOTES: 1. SIGNAGE SHALL COMPLY WITH I PANELS 21 FUTURE ACCESSORY HJC izz NFPA-55 CHAPTER 13 27 I BOARD m BASE REQUIREMENTS. GT1 A8 2 EPDXY FLOORING W/ PLAN @ TILE SECTION(@ EPDXY BASE 2. SIGNAGE TO BE FURNISHED AND INTEGRAL COVE A1. INSTALLED BY CO2 SYSTEM VENDOR. BASE ELEVATION SECTION 8 .25 CO2 WARNING SIGNAGE 26 RESTROOM TILE PATTERN LAYOUT 27 RESTROOM COVE BASE 29 RESTROOM SINK DETAIL 31 CORIAN PANEL DETAIL NOTE:ALL RESTROOM ACCESSORIES INSTALLED BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. A8.2 N.T.S. A8.2 3/8"=1'-0" A8.2 3"=1'-0" A8.2 3/4"=1'-0" A8.2 3"=1'-0" 2. REFERENCE SHEET EQ1 FOR SPECIFIC EQUIPMENT IDENTIFIED HERE-IN.