HomeMy WebLinkAbout5380 - Architectural Store RevisionPart-2 07/26/2021
4'-11"
51/2" 4'-0" 51/2" 3
2„ 1'-9„ 2„ 1' g„ 2" a N
o
U en o o .y
TOWER PEAK 'b a � � V �
33'-4" No(�
RF2 to
T.O.SHUTTERS
cd
O N O O
3 ��� ��� 13 -6 r '
A6.2 �_ 1 PBS N V1,c A-I fiI w
� I I
OVH2 I ^ I
G1 G1 I I EXTENT OF ALUM.
TOWER BRIG. - I I
26'-10" "It I I CLOSURE
DS2 PAR I I PANEL/FLANGE -J
EQ 2 10„ DS2 LAPPED BEHIND TRIM a
2 -10 EQ PVCT I I
co
FCST FCST
I I
� I I y
T.O.PARAPET I I B.O.SHUTTERS u
22'-4"
PVCT
� S
0 OFS PVCT W
T-11' 3'-4" '13'-4112" �3' 31/2" G1 RF2 3' 43/4". .' 98' 11 1l2
OFS / v
LINE OF TOP OF ROOF DS OFS LADD
- - - - V/
D S _ _
r..a
0000 0000 0 00 \N
3'-7" r 4'_11"- 3,-0 JST.BRIG.REAR - 5 U
2'-9� _. EQ SIGN EQ. 2, g f STU1` - - 16'-4 3/4" �--'
RSUP - DS DS2 A4.1 MTPN
„ „
TYP 3'-91/2" DS2 29'-5 3/4" 8 3114- 15 11 3/4 3 10
SCJ
OVH
STN2
LIGHT LIGHT a a 11 " " 1 1, 1 - 1/1 / LIGHT LIGHT SECURITY CAMERAS
FCST LOUVER. RE: RE: ELECTRICAL
FCS SCJ MECH. DWG'S. SCJ
I -_ T.O. MULLION&SILL
PAINT LOUVER EP6_ PBS PBS T-0"
TO MATCH STUCCO -
PVCT STU2 PVCT (--� STN1
1 LIGHT LIGHT o FCST
o
SOFF sTu1 sTu1 EQ EQ 3 BAHAMA SHUTTER DETAIL
wfpEQ EQ "-0- '
co
- ICE A4.1 112"=1'-0„
MTPN MTPN MTPN
CEMENT BOARD LAP SIDING
00
' T.O. MULLION&SILL OVER ONE LAYER HIGH
`� `� 3'-0" DENSITY POLYETHYLENE _, j M
BARRIER OVER ONE LAYER � c9
_SF BUTYL RUBBER MEMBRANE
BARRIER OVER 5/8"EXTERIOR
T.O.FLOOR SLAB GRADE PLYWOOD SHEATHING Q
STN2 14B 8 FCST EXTEND DOOR TRIM STN2 BOLLARDS 0 0 STARTER STRIP Q
A4.0 4 TO FINISH FLOOR,TYP DUPLEX
STN1 '47'0 YP ALL OUTLET A4.1 BEHIND DS 14A RECPT STN1 J
@ STONE VENEER DOWNSPOUT WITHIN A7,0 >-
TOWER LEG FRAMING WALL BEHIND LAP SIDING J U)
GENERATOR BOX.
1 REAR ELEVATION RE:DETAIL 17/A7.0 FOR
1/2"CPVC TRIM m Z
LU
INSTALLATION. RE: ELECTRICAL NOTE: ALL SIGNAGE WILL BE w Q ~ 0_
A4.1 114"=1'-0" FOR DIMENSIONS AND LOCATIONS. 1"CPVC TRIM a W
PERMITTED SEPARATELY. �, z Q
1x2 CPVC TRIM � w O Q
N co
CONT. FLASHING
ALUMINUM SHUTTERS.
4'-11" RE: ELEVATIONS
PRE-FINISHED 18-GA.WHITE
53/8" 4, 0„ 55/8" ALUMINUM CLOSURE PANEL
BEHIND SHUTTERS
RF3 TOWER PEAK 2" 1' 9" 2" 1'-9" 2"
33'-4" - WATER-RESISTIVE
-I' BARRIER
4 RF2
A6.2 _ __` T.O.SHUTTERS 8"METAL STUDS(TYP)
ALUMINUM SHUTTERS
OVH2 1 RE:ELEVATIONS
0
cfl I I O
SCJ G1
I I PRE-FINISHED 18GA.
2 WHITE ALUMINUM O 3
4 G1 i I PBS CLOSURE PANEL BEHIND _ 3
SHUTTERS
12'-91/2" A6.1 3'-1 1/4", EQ EQ 2.-6 3/4" I I WATER
DS2 STU1 - _ BARRIER
F T
M I I ' �-
LADD SAFETY CHAIN FCST PAR I I (2)16-GA STUDS AND(2)16-
T.O. PARAPET " I I GA)TRACKS TOP&BOTTOM. o
I I EXTENT OF ALUM.
STU1 22' 4" I
SIGN M I I CLOSURE GWB RE:
PANEL/FLANGE T �
PLAN
PVCT F RE RESISTANT EXTERIOR
YWOOD GRADE
I I TRIM LC�
I I LAPPED BEHIND WALL TYPE
FOR
¢ co
SCJ
LINE OF TOP OF SHEATHING AT ENTIRE SURFACE
----
ROOF BEYOND - _ -- -- - --- -- - B.O.SHUTTERS a LLI
--23'-10'-------------------- --.---- --- „
-- ---- --
CONT FLASHING CONT
---- 22 -5 v 11' 11' r / / i EQ `�' 7-2" PERIMETER
BEHIND SIGN.
i
------ i � / i i SEALANT � LL
DS2 SIGN,BY SIGN CONTRACTOR. CONT.SEALANT,TOP AND O 0
'-61/8" 9' 0 7/8" PROVIDE BLOCKING PER MTPN SIDES O N U)
FCST SIGNAGE MFR'S REQUIREMENTS. 11'-11" SECURITY CAMERAS TYP ROLLER
Z
SEE DETAIL 3/A5.0: RE: ELECTRICAL PVCT
o PROVIDE END DAMS SHADE. RE: O
SIGN LIGHT SCJ . ,
_ STU1 @ SILL(TYP.) ELEVATIONS r
STU1 STU1 CONT.SILL"Z"FLASHING. CN
z
O
0
FCS - FCST 0 �_
LIGHT DO NOT SEALANT
11 3 . 11 -2 . , BETWEEN SILL AND CONT.
FLA
- SEASANT SEALA
NT m
PVCT PERIMETER � w
T.O.MULLION&SILL C7 J
PBS 3 -0 BENEATH L-L�
MTPN2 LGD MTPN2 o PVCT �� FCS00
FLASHING ONLY ;u
LIGHT o TG o TG STN2
FCST FCST
(1) 16-GA STUD AND
DS1 EP1 EP1 / o LIGHT 5 STN1 (2)16GA)TRACK. ULu
a Q w rJ �
#1 N 8"METAL STUDS(TYP) � w
CO2 0
STN1 -,o o MTPN MTPN STN1 A4.0 METAL PANEL. INSTALL PER v Q 'i
/ MFR. RECOMMENDATIONS. 2 z FL w
Z J
STN2 D1 5, „ 4' 11" 3' 2" 4' 11" 5' 5" STN2 ELEVATIONS = ~
CO
11 RE: E rJ
T.O. MULLION&SILL o O u- w W
3� 4 BAHAMA SHUTTER DETAIL 5 EXTERIOR WINDOW SECTION N
STN1 o \ 0 STN1 A4.1 1/2"=1'-0" A4.1 3"=V-0" o
o N
i I
\ N T.O.FLOOR SLAB b OF•Fop
STN2 GENERAL NOTES Digitally signed byR SDa
_ WALL HYDRANT 3 a G r
6"X 6"ACCESS PANEL EXTEND DOOR TRIM DUPLEX RECTP VINYL FENCE BOLLARD(TYP.) gERT&=c�N belS 01
A4.1 oDooaoats o z s,
FOR TEMPORARY TO FINISH FLOOR,TYP FOR ICE - STORE NUMBER SIGN 2"HIGH STN1 o=c AND PETE I c
SPECIAL 1. ALL BLOCKING @ HARDIE FOR LIGHTS,SECURITY ITEMS.SEE DETAIL 18/A7. y L _ ENGINEERSPLANI�E S
WATER HOOKUP. 7 MERCHANDISER. NUMBERS,COLOR BLACK. 8 PURPOSE 2. MOUNT SECURITY CAMERAS THE SAME HEIGHT AS THE EXTERIOR WALL FIXTURE • ContactlnfoaThisdocu ntts° n
ALIGN WITH VISION GLASS !S ���/electronically signed 40 tyto art
A4.1 CO2 WARNING A4.0 RECEPTACLE 3. PROVIDE 6"X 8"ELECTRICAL BOX STONE TRIM BY BOULDER CREEK, COLOR ANTIQUE TAN AT °d Day usfliga Digital rio�gd pi
SIGNAGE TYP ALL OUTLET L of his comment are t nrri e
ALL EXTERIOR ELECTRICAL RECEPTACLES MOUNTED ON STONE. SEE DETAIL 8/A4. C and sealed and the s reim ube ri d
2 LEFT ELEVATION @STONE VENEER 4. PETERSEN PAC-CLAD IS AN ACCEPTABLE ALTERNATE MFR. FOR PRODUCTS WHERE"ATAS"IS a Date 2 2;00.261 04'Bo•
A4.1 114"=1'-0" SPECIFIED. PROVIDE EQUAL OR BETTER QUALITY PRODUCTS.SUBMIT PRODUCT DATA TO � _
ARCHITECT FOR APPROVAL.
a
07/21/2021
A CO2 FILL PORT ARCHITECTURAL - EXTERIOR FINISH SCHEDULE ARCHITECTURAL - EXTERIOR FINISH SCHEDULE N N N N N
C" +�+ N IN N N N
SYMBOL MATERIAL MANUFACTURER COLOR NOTES SYMBOL MATERIAL MANUFACTURER COLOR NOTES m ► co
- M
N N O N
CO2 CO2 FILL BOX WITH PVC SLEEVE THRU WALL SUPPLIER LO ATION AND MOUNTING DETAIL RE: PAR ALUMINUM PARAPET CAP ATAS INTERNATIONAL INC. COLOR TO MATCH ADJACENT TRIM ALTERNATE:PETERSEN PAC CLAD It (o (o i
ti ti
O O O O O
DETAIL 7/A4.1 A PBS PREFINISHED ALUMINUM BAHAMA SHUTTER FENWALL FABRICATION& COLOR TO MATCH ADJACENT TRIM SHUTTER PER SPECS. CONTACT: KERRI BEALS
DS ALUMINUM THRUWALL SCUPPER& ATAS INTERNATIONAL INC. POLISHED ALUMINUM W/CLEAR ANODIZED FINISH D A WITH CIVIL FOR CONNECTION TO STORM MFG. 813.343.5979,
COLLECTOR AND 4"DIA.ALUMINUM SEWER. SEE DETAIL 14A&14B/A7.0.ALTERNATE: ALTERNATE: SUPERIOR CUSTOM SHUTTERS,CONTACT: o
DOWNSPOUT PETERSEN PAC CLAD DAVID DANIELS 407.949.1969
T.O.MULLION&SILL � V) c O
3'-0" DS1 4"DIA.ALUMINUM DOWNSPOUT. REFER TO ATAS INTERNATIONAL INC. POLISHED ALUMINUM W/CLEAR ANODIZED FINISH COORDINATE WITH CIVIL FOR CONNECTION TO STORM PVCT ACCENT TRIM AZEK WHITE, FINISH:SMOOTH;SEE DRAWINGS FOR DIMENSIONS PRE-FINISHED, ALTERNATE:PALIGHT o }' Ln
SPECS FOR GAUGE SEWER.SEE DETAIL 14A&14B/A7.0.ALTERNATE: RF2 METAL ROOFING ATAS INTERNATIONAL INC. MRD194 DUTCH SEAM,(1 1/2")19.25",COLOR:#23 COPPERTONE ALTERNATE:PETERSEN PAC CLAD m y w w w
PETERSEN PAC CLAD RF3 STANDING SEAM ROOF HIP CAP ATAS INTERNATIONAL INC. TO MATCH METAL ROOFING ALTERNATE:PETERSEN PAC CLAD = m L W w
DS2 4"DIA.ALUMINUM DOWNSPOUT ATAS INTERNATIONAL INC. POLISHED ALUMINUM W/CLEAR ANODIZED FINISH ALTERNATE:PETERSEN PAC CLAD ~ w ~
0 6X6 ACCESS PANEL RSUP ROD SUPPORT&PLATE POWDER COAT,MATCH SW#6076 SEE STRUCTURAL.ALL RODS NOT INDICATED ON g N m �
EP1 PAINT BENJAMIN MOORE COLOR:WHITE DIAMOND 2121-60 FINISH:EGGSHELL DOOR&FRAME STRUCTURAL ARE PURELY DECORATIVE RE:21/A3.1 w w Lu u w
FOR TEMPORARY 1 4 EP6 PAINT BENJAMIN MOORE COLOR:WESTMINSTER GOLD#200, FINISH:SEMI-GLOSS SCJ STUCCO CONTROL JOINT-3/4"WIDE 'W SHAPED ACCORDION STYLE RE:SPECS 0- Of a 00 0-
WATER HOOKUP. EMERGENCY
CL FCS ARTISAN FIBER CEMENT LAP SIDING JAMES HARDIE COLOR:HARRIS CREAM, FINISH:SMOOTH,8.25"X 12' PRE-FINSHED.PROVIDE COLOR-MATCHED CAULK BY SIGN ILLUMINATED SIGNAGE SIGN BY WAWA,SURFACE MOUNTED;PERMITTED c
3'-5" OVERFLOW
JAMES HARDIE � Z
SEPERATELY Q
PROVIDE SCUPPER FCST ARTISAN FIBER CEMENT ACCENT TRIM JAMES HARDIE COLOR:ARCTIC WHITE,FINISH:SMOOTH, 1.5"TH x 6"W x 10'-0"L PRE-FINSHED.PROVIDE COLOR-MATCHED CAULK BY SOFF MPS120,SOLID AND VENTED ATAS INTERNATIONAL INC. BONE WHITE BUILDING OVERHANGS.ALTERNATE:PETERSEN PAC-CLAD
WITH SLOTS JAMES HARDIE SPAN SPANDREL GLASS, 1"INSULATED TEMPERED VERICON SUBDUED BRONZE FRIT TO BE ON INSIDE OF PANEL a
`" G1 ALUMINUM GUTTERS POLISHED ALUMINUM W/CLEAR ANODIZED FINISH CONTINUOUS-NO SEAMS ALLOWED.SEE SHEET A3.1 STN1 MANUFACTURED STONE VENEER BORAL SOUTHWEST BLEND PF 8019,PRO-FIT LEDGESTONE
ICE ICE MERCHANDISER LEER PAINT BENJAMIN MOORE,BM OC-1 NATURAL WICKER „ = s a
COLLECTOR BOX co STN2 PRE-CAST MANUFACTURED STONE BORAL TAUPE CSV-1375 VERTICAL GROUT JOINTS:3/16 MAX.WIDTH.GROUT WITH ¢m p o 0
_ T.O.FLOOR SLAB co
LADD METAL EXTERIOR LADDER EASTERN METAL SUPPLY BRUSHED ALUMINUM E SHE T!Z.1 OR D T LS A WATERTABLEISILL BONSAL#71 WARM IVORY Z rn N p
0'-0° LGD 6'LADDER GUARD#LG6 VISIONMASTERS EQUIP. FINISH:MILL STN6 PRE-CAST STONE CAP ITALIAN CAST STONE COLOR:WHITE SEE SHEET A10.GROUT JOINTS 3/16"MAX.WIDTH.COLOR: }o Lu CD w 3 a v ¢ N
N CO. WHITE(TO MATCH STONE CAP) ao m o c�I 1 o ¢ w c9 N
2 -- ------- ----
1'-4" LIGHT EXTERIOR LIGHT FIXTURE SEE ELECTRICAL DRAWINGS AND DETAIL 18/A7.0 FOR STOR STOREFRONT SYSTEM KAWNEER CLEAR ANODIZED SEE SPECIFICATIONS U a 0
A7.0 , MOUNTING STU1 STUCCO SENERGY #3085 MERINGUE,FINISH:SAHARA
ROOF SURFACE MTPN METAL PANEL q FENWALL FABRICATION& OLOR TO MATCH ADJACENT TRIM BAHAMA SHUTTERS ASSEMBLY.CONTACT(407)408-3932. STU2 STUCCO SENERGY #308 STARK WHITE, FINISH:FINE
MFG. RE:DETAIL 5/A4.0 TG 1"INSULATED TEMPERED GLASS SEE SPECIFICATIONS A4 . 1
MTPN2 METAL PANEL FENWALL FABRICATION& AINT TO MATCH DOORS, EP1 PANEL ABOVE DOOR.CONTACT(407)408-3932; RE: DETAIL TGT 1"INSULATED TEMPERED GLASS VITRO ARCHITECTURE GRAYLITE II. SEE SPECS SEE SPECIFICATIONS
FG. 6/A4.0
7 CO2 AND WATER HOOKUP DETAIL g SCUPPER AND OVERFLOW DETAIL OFS ALUMINUM 8"X 16"OVERFLOW SCUPPER ATAS INTERNATIONAL INC. POLISHED ALUMINUM W/CLEAR ANODIZED FINISH ALTERNATE:PETERSON PAC CLAD
OVH METAL OVERHANG FACING ATAS INTERNATIONAL INC. RAPID-LOK FASCIA&RAPID-LOK COPING,COLOR:#17 BRITE RED SEE A3.1 FOR DETAILS.ALTERNATE:PETERSON PAC CLAD
A4.1 314"=1'-0" A4.1 V.=1'-0" OVH2 HIP ROOF FASCIA ATAS INTERNATIONAL INC. BRAKE METAL,COLOR#26 BONE WHITE SEE A3.1 FOR DETAILS.ALTERNATE:PETERSON PAC CLAD A
07/26/2021
1 3�
A6.0 NOTE: ALL EXTERIOR N
a o
TOWER PEAK
� 33'-4" - - - - - - - - - - - - WALLS TO HAVE R-30 N o
U cn o o O
INSULATION w � 1
(8
MN
RF2
iz� o
1
A6.2
DS2 2' 10" EQ. EQ - _ 2'-10"` DS2
BACK OF PARAPET
BEYOND - - ; • SCJ
T.O. PARAPET // - WALL HYDRANT T.o. PAR�PE� v� a
• AP5 4
ROOF DECK&INSULATION co
(V t4
JST. BRG. MID FRONT W
I I v �
I I I
Tn�,�x®od SUSPENDED ACOUSTICAL
TILE CEILING
6 '
COFFEE p O RETAIL ARE
III I SELF SERVICE I I
WALK-IN REFRIG.
I I I I
T.O. FLOOR SLAB M
0'-0"
W O
O . O � �_
- W Z
� Q
BUILDING SECTION
A5.0 - � J
114"-1'-0" U)
J
Q Z
00 Z
Q W
LU CL
z W Q
w Q p
0 � N �
2 — — — T.O.PARAPET
A6.1 22'-4"
LIGHT FIXTURE
RE: ELECTRICAL
I I
SLOPE: 114"/ 12"
JST. BRG. FRONT
17--101,
SUSPENDED ACOUSTICAL N
TILE CEILING° JST. BRIG. REAR
16'-4 3/4" o
0
RETAIL WALK-IN '� RETAIL WALK-IN 3
BEER COOLER REFRIGERATOR r
3
� BEERCOOLERD � D DD
o
a
BEER r
_ o
' O� -
I o 0
00
M
RETAIL AREA \ RETAIL WALK-IN
EFRIG. m
W
i i m
00
T.O. FLOOR SLAB
a a a, Or or,
o
T CD
CN42
O
O = I--
U
CN
8 m z W
Cn
'2� BUILDING SECTION N
OO J
QILL
w z
0 wQW0f 0
0 W w J
LAP SIDING PER FINISH Z Q J —
SCHEDULE „ o � 0 I w m
CO
ONE LAYER HIGH-DENSITY a
POLYETHYLENE BARRIER N
OVER ONE LAYER BUTYL
RUBBER MEMBRANE 5/8"PLYWOOD FLOA
5/8"FRT PLYWOOD BEHIND RIGID INSULATION(TYP7t4 .) a 4 Digitally signed by R SDay
C==SIGNAGE RE:ROOF PLAN, SHEET �, CN=Robert 00 1
6' 7/8"STUCCO FINISH OVER 3.4#SELF c� ZpgERT0 yp� ANDPol8 7� go 2 s,
8"METAL STUDS A3.0 o=c ANDPETE hta C
ti ENGINEERS PLANNE S
FURRING GALVANIZED METAL LATH p,;,.� Reason:I have reviewe icn.
GOOSE LOGO SIGN 8"METAL STUDS @ 16"O.C. FRb S Flay Contact Into This dono nt as tLen
OVER ONE LAYER HIGH DENSITY `z�R electronically signed s 0I<Ro art
Day usfig a Digital S n d pi
1/2"LIQUID TIGHT STEEL TUBE. RE:STRUCTURAL METAL DECK. POLYETHYLENE BARRIER OVER ONE L of this document are t n rJs
and sealed and the s uraMu9t a art d
T Date 2 21.07.2615:I 31-04'B0'
CONNECTOR — — RE:STRUCTURAL R30 BATT INSULATION
_ LAYER BUTYL RUBBER MEMBRANE 0
ANCHOR PER MFR. SPRAY ALL VOIDS GWB TO UNDERSIDE OF BARRIER OVER 5/8"EXTERIOR GRADE
PLYWOOD SHEATHING
5/8"EXTERIOR GRADE PLYWOOD WITH FOAM SEALANT DECK(TYP.)ALL EXT. RE: EXTERIOR ELEVATIONS a .r
1/4"-20 ANCHOR BOLT TO WALLS 07/21/2021
SPACER SLEEVE AT EACH BE DETERMINED BY WALL ° STEEL BEAM. AZEK TRIM(BEYOND)
ANCHOR,AS SHOWN °
TYPE RE:STRUCTURAL ` RE: EXTERIOR ELEVATIONS N N IN N N
N 7/8"STUCCO FINISH OVER 3.4# 1/2"GWB 20 O O O O O
GWB TO UNDERSIDE A3.2 M N N N N N
2"X 2"X 1/8"STEEL ANGLE, SELF FURRING GALVANIZED METAL G i CO CO o0
N N O N
TYP LATH OVER ONE LAYER HIGH OF DECK(TYP.)ALL TUBE STEEL BEAM N It o o r- r-
LISTED DISCONNECT DENSITY POLYETHYLENE BARRIER VESTIBULE WALLS I I o 0 0 0 0
"WAWA"LOGO SIGN — OVER ONE LAYER BUTYL RUBBER RE:STRUCTURAL 3
a�
SWITCH r INSULATE
MEMBRANE BARRIER OVER 5/8 EXTEND ROOFING MEMBRANE UP �
DOWNLIGHT. VOIDS AT BEAM 8"METAL STUDS @ 16"O.C. D
TRANSFORMER BOX EXTERIOR GRADE PLYWOOD WALL MIN.8"VERT. Im RE: ELECTRICAL SHEATHING.RE: EXTERIOR y c O
LED POWER SUPPLY ELEVATIONS 8"METAL STUDS R30 BATT INSULATION _
6"METAL FRAMING c 2
o _ �
1/2"LIQUID TIGHT 1/2"LISTED FLEX(LIQUID @ 16"O.C.,TYP (TYP.)
y ` ~ >
RE:STRUCTURAL 5/8"PLYWOOD SHEATHING LU
TAPERED INSULATION BOARD o uwi
❑ oN o H H CONNECTOR TIGHT SHOWN) � 8"METAL STUDS @ 16"O.C. —
METAL DECK = N m g
ANCHOR PER MFR. TO PRIMARY SOURCE - w w w ❑ w
HEADER RE:STRUCTURAL � > w �
1-1/2"18 GA FURRING RE:STRUCTURAL LIGHT GAUGE METAL FRAMING o m a
1/4"20 ANCHOR BOLT TO WRAP ONE LAYER HIGH DENSITY R30 BATT c
SPACER SLEEVE AT EACH BE DETERMINED BY WALL POLYETHYLENE BARRIER AND ONE INSULATION RE:STRUCTURAL o 0TTFFIJ
ANCHOR,AS SHOWN TYPE LAYER BUTYL RUBBER MEMBRANE STOREFRONT B.O.OVERHANG Z Q
BARRIER UNDER BOTTOM OF SOFFIT Sim. 9,-0„
2"X 2"X 1/8"STEEL ANGLE, SOFF AND INTO STOREFRONT ROUGH 9 a
SPACER CUT ANGLE SHALL MATCH TYP ' 12"WIDE SOFFIT PANELS OPENING I — A3.2 1 1/2" 18 GA FURRING @ 12"O.C. -
LAP SIDING SLOPE. PROVIDE SOFFIT o
LISTED DISCONNECT +/_2r_2" �s a
LIQUID TIGHT MASTIC,TYP — SWITCH EQ EQ CENTER DOWNLIGHT WRAP ONE LAYER HIGH DENSITY RE: EXTERIOR ELEVATION SCHEDULE a m o 0
ON SOFFIT PANELS — — — 8"-16 GA METAL POLYETHYLENE BARRIER AND ONE UNVENTED SOFFIT THIS A EA o Z � CD
N
TRANSFORMER BOX T.O.CLERESTORY - STUDS @ 24"O.C. LAYER BUTYL RUBBER MEMBRANE LIGHT FIXTURE }o '� CD w R a v Q N
LED POWER SUPPLY 6 - _ - _ _ = - - ; '= BARRIER UNDER BOTTOM OF SOFFIT RE: ELECTRICAL g o �, o a Q w c� N
NOTE:TRANSFORMER BOXES TO BE LOCATED `__ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___ = 5/8"M.R.GWB CEILING AND INTO STOREFRONT ROUGH a o o U
ABOVE CEILING AND BELOW ROOF DECK. NO 1/2 LISTED FLEX(LIQUID OPENING CONT. P.T.WOOD BUCKS SHALL BE
ROOF OR PARAPET PENETRATIONS ALLOWED. TIGHT SHOWN) -___ ATTACHED USING HILTI KWIK-PRO
STOREFRONT SELF DRILLING SCREWS S-WW
TO PRIMARY SOURCE 14X20X2-3/4"PFH#4 WINGS @ 18"Q.C. A5 . 0
3 SIGNAGE DETAIL LAP SIDING IF REQ'D) 4 PORCH/ENTRY SOFFIT 5 " SOFFIT DETAIL FRONT ENTRY �60, SOFFIT DETAIL SIDE ENTRY _
A5.0 1rr=1'-0" A5.0� 1"=1'-Orr
A5.0 1"=1'-0" A5.0 1 112"=1'-01, ,
07/26/2021
STORFRONT LEGEND
e
9'-3" 9'-3" 8 91/2 TEMPERED GLASS P-+ N
N n n 4'-1 3/4" 2" 4'-1 3/4" 2' y o
4'-4" 2" 4'-5' 2 4'-41/2 2' 4'-4 1/2 2 OR Or OR OR Or
00CV N N
U cn o o .oy
M SPANDRAL GLASS N 9 o
t\ r- o� o
TG TG TG TGT TGT TGT TGT TGT TGT .�. . o
_ = N V1� Q•I W � w
" 4'-6 1/4" 2" 6'-01/2" 2" 4'-6 1/4" 2'
METAL TRANSOM
SF STOREFRONT ELEVATION SF STOREFRONT ELEVATION SF STOREFRONT ELEVATION SFg STOREFRONT ELEVATION
� �
A5.1 112"=1'-0" A5.1 112"=1'-0" A5.1 112"=1'-0" a
cd
15'-91, 11'-03/8" 9'-3" 9'_3" 8'-91/2"
4 61/2 2" 6 0 2 4 61/2 2 2'-2" 2" 6'-0" 2" 2'-2 3/8" 2' 2 /8" 4'-5 3/4" 2" 4'-2 7/8" 2' 4'-41/2" 2" 4'-41/2" 2' 4'-1 3/4" 2" 4'-1 3/4" 2' ,0
N CV N N N
CV N \\
\N U
TG TG
CV CV
o V1 o 0 0
C7 C?
OO 00 00 Oo // 00
O / \
'� \ / TG TG TG TG TG TG TG
CV \\ // CV \\ // CV N CV
N TG \\ TG N TG \\ TG CV cV N
TG \ / TG TG \ / TG SPAN SPAN TG TG TG TG
N N N N N M
I_I_I
^Y
I..L
SF STOREFRONT ELEVATION SF3 STOREFRONT ELEVATION SF STOREFRONT ELEVATION SF STOREFRONT ELEVATION SF STOREFRONT ELEVATION 0 Q
A5.1 112"=1'-0° A5.1 112"=1'-0"
1/2" A5.1 1/2"=1'-0" A5.1 112"=1'-0" J
1l'-51/2" 4'-5 5/8" 4'-63/4" 9'-31/2" 9'-31/2" 4'-On Q Z
OR
CID
6' 0" 2" 4'-11 1/2" 2' n 4'-1 5/8" 2' 4'f or -2 3/4" 2' n � n n 1 4 -4 7/8 2" 4'-4 5/8" 2' " 3'-8" 2' W W 4 4 3/4 2 4' 4 3/4" 2 �
CV CV CV 04 04 CV
w Q o Q
CO CV CO CV (O CV // CO CV CO CV CO CV U N
TGT TGT TG TGT 2L=
TGT SPAN SPAN SPAN
I C="l I L
F1 STOREFRONT ELEVATION F1 STOREFRONT ELEVATION F1 STOREFRONT ELEVATION F1 STOREFRONT ELEVATION F1 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION
5• 112"=1'-0" 5• 112"=1'-0" 5• 112"=1'-0" A5• 112"=1'-0"
A5.1 1/2"=1'-0" A5.1 1/2"=1'-0"
1 l'-51/2" 4'-7 1/8"
n 6'-0" 2e 4'-11 1/2" 2' " 1'-1 1/8"2" 3'-0" 2, o_
U
Or lrlr E
0
N N 4'-63/4" 9'-31/2" 9'-31/2" 4'-0" o
1.
4' 2 3l4" 2'
" 4'-4 3/4" 2" 4'-4 3/4" 2' 4'-4 3/4" 2" 4'-4 3/4" 2' " 3'-8" 2'OR
a
- CV CV CV CV 3
TG TG
3
CV
m
/ \
V2 ; / \ o o / V3
/ \ \ o
/ \ \ 0
/ \ CV \ O Oo O B0 O B0 O OO w M
M. w
a M
oo \ L0
0
w
\ / N N
0
TG TG TG TG
TG \\ TG CV CV TG
0 - - - - O LU
\ / TG TG / o 0 0 o Z, �
CV GV = M M M C+M
3 N J
m = ui
C/)
FINISH FLOOR, NTS FINISH FLOOR, NTS FINISH FLOOR, NTS FINISH FLOOR, NTS 8 m Z Z
LL
L �( 0
F1 STOREFRONT ELEVATION F� STOREFRONT ELEVATION Fl STOREFRONT ELEVATION Fl STOREFRONT ELEVATION Fl STOREFRONT ELEVATION F2 STOREFRONT ELEVATION N 00 °v J
A5.1 1/2"=1'-Orr U
I_I-I �
1 11 5• 112"=1'-0" 5• 112"=1'-Orr 5. / 112"=1'-Orr
LU
8 61/2 nn 8' 611/2" nn 4 1n L1J
6' 6114" ME � CD LU LU
4'-0" 2" 4'-01/2" 2' 4'-01/4 2 4'-0 1/4 2 2y 3'-77/8 L 3'-9 2 6' 2114" 2' a z Q QN - 0
0 ILL w V
m W I L H
O W
� 2
a N
N
CO CV CO CV CO CV
CO CV CO CV
CV CV CV N b
CV N N N N N
d
SPAN SPAN SPAN SPAN SPAN TG m ,
0
TG
a Digitally signed by R S Day
e e G g�v Cbert S Da
Ilc oC OAND PETE 0 C 9.
w • ENGINEERS PLANI�EJS
L EV F E L 6'-4" F �p--��n l Rayson g av 9 tal c n
fJ .S 1 1 a\/Contact Info:This docu nt as men
�[A.J �.J VF1I�^Y electronically signed �qgl touy���ggRo art
F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F3 STOREFRONT ELEVATION F3 STOREFRONT ELEVATION o thsd a elnt alre t nrrdi e
C and sealed and the s re0u9tlhe ri d
F2 STOREFRONT ELEVATION 1 /4" 6'-0" 21 " „_ r „_ , r, U on any elecOiNnicooi ry
5• 112 -1-0"
A5.1 112 -1-0 a Date:2021.07.26 15: :36-OCKO'
8'-61/2" N
07/21/2021
" 4' 01/4" 2" 4'-01/4" 2' nn 6'-4"
Or Or Or Or lrlr OR OR
" 4'-01/4" 2" 4'-01/4" 2' - 2 3'-7718 2
CD
" 6'-0" 2-16' 6114" o 0 0 0
N N N TG 4' 1" 40 N d
N N N N
I- CO CO
n n 6'-21/4" 2' N � � NON
/ \ / \ 2' d O O O O
C Z
C O
O OO O OO O OO e / / \ \ / / \ \ ° ° - = O V W W W
/ \ / \ a y C ~to U) W >
// \\ / \ o 00 / ) 0 W
CO En CO En Cfl Cf')
/ \
w
N = N = / / \ o w W Q'
C� / o
8 d d m d
TG jr
TG z°
TG TG TG TG TG
TG \\ TG TG \\ TG � � o a z o
N o
l() LC) 2 ti O N 0 e7
o Z W
0
>o " 00 W V Q N
O O O \ / \ / p m O N F O Q W ( N
U O d 0 (�
M M M FINISH FLOOR, NTS FINISH FLOOR, NTS
FINISH FLOOR, NTS FINISH FLOOR, NTS FINISH FLOOR, NTS A5 . 1
F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F2 STOREFRONT ELEVATION F3 STOREFRONT ELEVATION F3 STOREFRONT ELEVATION
A5.1 1/2"=1'-0" A5.1 1/2"=1'-0" A5.1 1/2"=1'-0" A5.1 1/2"=1'-0" A5.1 112"=1'-0" A5.1 112"=1'-0"
07/26/2021
A B C 4 5 6
a )��12
U cn o o 4�4
TOWER PEAK TOWER PEAK _`t CD
33' 4" 33' 4" 1.4
N��
PRE-ENGINEERED ROOF
TRUSS FRAMING. RE: STRUCTURAL 12"
12"
5/8"EXTERIOR GRADE 6 6"
� �
PLYWOOD
STANDING SEAM METAL \ a
ROOF.RE:A4.0 EXTERIORA �\
FINISH SCHEDULE
1
A3.2 - - -
V
TOWER BRIG. TOWER BRIG U
26'-10" 26'-10"
GUTTER, PERIMETER 4
OF FASCIA 7/8"STUCCO FINISH OVER 3.4# c v`
SELF-FURRING GALVANIZED V
7/8"STUCCO FINISH A METAL LATH OVER ONE LAYER I _
OVER 3.4#SELF-FURRING GALVANIZED HIGH DENSITY POLYETHYLENE -
METAL LATH OVER ONE LAYER HIGH — BARRIER OVER ONE LAYER A
DENSITY POLYETHYLENE BARRIER OVER 3 BUTYL RUBBER MEMBRANE 5/8"EXTERIOR GRADE F.R.T.
ONE LAYER BUTYL RUBBER MEMBRANE A6.0 BARRIER OVER 5/8"EXTERIOR PLYWOOD CONT AT TOWER
BARRIER OVER 5/8"EXTERIOR GRADE GRADE PLYWOOD SHEATHING I INTERIOR UP TO 48"ABOVE
PLYWOOD SHEATHING 5/8"EXTERIOR GRADE I DECK
F.R.T. PLYWOOD. CONT.AT RAINSHIELD
TOWER INTERIOR UP TO
5/8"EXTERIOR GRADE FIRE 48"ABOVE DECK
RESISTANT PLYWOOD SHEATHING AT
ENTIRE WALL SURFACE BEHIND SIGN `" AP5 8"METAL STUD.
SIGN,BY SIGN zo RE:STRUCTURAL
CONTRACTOR I
CA
�
COORDINATE SIGNAGE 5/8"PLYWOOD OVER RIGID
� INSULATION 36"X 48"ACCESS HATCH. � 5/8"PLYWOOD OVER RIGID
BLOCKING PER MNAG SPRAY-FOAM SEAL ALL RE: DOOR SCHEDULE INSULATION
REQUIREMENTS RE: ROOF PLAN,SHEET A3.0 STEEL PENETRATIONS RE:ROOF PLAN,SHEET �� 36"X 48"ACCESS DOOR.
_ THROUGH ROOF DECK(TYP.) SINGLE PLY ROOFING A3.0
5 RE: DOOR SCHEDULE
SYSTEM OVER RIGID
A5.0 O° INSULATION(TYP.) C-0
RE: ROOF PLAN,SHEET A3.0
Y �
STEELTUBE
JST. BRG. FRONT � �
RE:STRUCTURAL 17' 10" W Q
INSULATE VOIDS AT BEAMS Z
8"METAL STUD TYP I I I FOAM SEALAY ALL VOIDS WITH I RE-STRUCTURAL
STEEL BEAM j
RE:STRUCTURAL
I STEEL JOIST. GWB TO UNDERSIDE OF I Q Z
R30 BATT INSULATION I RE:STRUCTURAL DECKSTYP.)ALL EXT. fi m Z
w Q W
7/8"STUCCO FINISH OVER 3.4#SELF
FURRING GALVANIZED METAL LATH z Q
8"16-GA. MTL.STUDS 24"O.C. I HEADER INSULATE VOIDS a W
OVER ONE LAYER HIGH DENSITY I @ RE:STRUCTURAL 8"16-GA. MTL.STUDS@ 24"O.C. AT BEAM z Q o
POLYETHYLENE BARRIER OVER ONE _, _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ J Q
LAYER BUTYL RUBBER MEMBRANE — — — — — — — — — — — — — — — — — — — — — — — — — — - - - — — - - — — - - — — - - — — I �' N
BARRIER OVER 5/8"EXTERIOR GRADE — — T.O.CLERESTORY R30 BATT INSULATION
PLYWOOD SHEATHING, BEYOND. - = __ _ = 13'-6" —
RE: EXTERIOR ELEVATIONS = _ _ •' 5/8"M.R.GWB CEILING SUSPENDED ACOUSTICAL
RECESSED LIGHTING - TILE CEILING
RE: ELECTRICAL EXIT SIGN 5/8"M.R. GWB CEILING
STOREFRONT SYSTEM
PREFINISHED BRAKE METAL OVER ONE LAYER - B.O.CLERESTORY
HIGH DENSITY POLYETHYLENE BARRIER OVER
ONE LAYER BUTYL RUBBER MEMBRANE
BARRIER.BRAKE METAL TO MATCH 6
STOREFRONT A5.0 o
8"MTL FRAMING
TUBE STEEL BEAM.RE:STRUCTURAL
_ B.O. OVERHANG B.O. OVERHANG
WHITE STUCCO BAND HEADER 9' 0" 9' 0"
BEYOND RE:STRUCTURAL
j
EXTERIOR LIGHT FIXTURE. 3
FIXTURE SHALL BE SECURED 5 / STOREFRONT PORCH OVERHANG
AGAINST MOVEMENT/
ROTATION.RE: ELECTRICAL A6.0
VESTIBULE 25lo
2s
STOREFRONT SYSTEM
ADHERED MANUFACTURED STONE \� 25 i� �� 00
VENEER BEYOND �� p`9 0 i� \� ADHERED CM
� � MANUFACTURED � Lf�
co
KNOX BOX V2 ��\ VESTIBULE STONE VENEER L J
PRE-CAST ADHERED MFD T.O. MULLION&SILL \� T.O. MULLION&SILL
STONE WATERTABLE/SILL �� 3' 0" �� - 3' 0" O LU
BEYOND �i I `� �� 28 m 0
A7.0 0
o
i I i Q
1/2"EXPANSION JOINT
i TERRAZZO FLOOR FINISH Z TERRAZZO FLOOR FINISH W/SEALANT(TYP) N
T.O. FLOOR SLABLLL T.O. FLOOR SLAB ACV Z
-• _ Q 0'� - - - ad_ - a ° - _ Qe da <-d �
_ _
a- ,
a � n
a
a
a a,
a
1/2"EXPANSION JOINT a' CONCRETE SLAB,
W/SEALANT,TYP CONCRETE SLAB, - LO
RE: RE:STRUCTURAL 00 0 J U
LL W LL W
a
Q Q U Cn
0
W LU � J
o Q z w LEI
J
QQ
Ji
LEI
a G Digitally signed by R S Day
CC®Nyy-p{Robert S Da DO 00016JQ�O LOgERT(cU WAND PETE MRF�F 10 C 12 0,
ti _ ENGINEERS PLANNE C�1S
A Reason: have rs donu cten.
``J Contact Info:This docu nt as men
y electronically signed s 40 b<o ert
�[1 Day usfig a Digital S rigo�gpd pi
of this document are t n re e
1 TOWER SECTION 2 TOWER SECTION L
and sealed and the s urea Ou=e n d
U on any wect nic cc i . rryy
Date:2021.07.2615: 43-ON't70'
07/21/2021
N
4'-6"
o
N N N N N
O O O O O
M N N N N N
2'-3" GL 2'-3" `° i (M C0 o -
D N N O N
WD.BLOCKING SET UP ROOF CAP FIELD It (0 (0 r- r-
LIGHT FIXTURE A FROM BOTTOM EDGE ROOF CAP FIELD
LIGHT
OF CAP TO ALLOW FABRICATED FROM CAP HIP COVER FABRICATED FROM 00000
FLAT SHEET PROVIDED 5
FOR Z-CLOSURE FLAT SHEET
BY MTL ROOF MFR m
WRAP W/ICE&WATER I z
CONT.SEALANT I I CUT MIN.4 1/2" SHEATHING 8"+/ SHIELD MIDPOINT BLOCKING c r_
N G O
MOUNT J-BOX 1 1 DIA. HOLE FOR J 2X PLUS 5/8"PLWD. o L
FLUSH W/FACE OF I I BOX - - -------- CAP HIP COVER 2 LAYERS,5/8" ALLOW GAPS IN y w w w
\ VENTILATION I SHEATHING = > N cn
I I 31/2" BLOCKING FOR AIR
MOUNTING BLOCK N ❑
I I OPENING IN FLOW 16
= m
I 1 I SHEATHING 2X WD. BLOCKING
PEMKO#346C I I sr I 0- � 0-
m d
METAL ROOF PANEL w w � O w
DOOR TOP I I 8 I I g VENTILATED Z- o
WEATHERSTRIP, LT FIXT.OUTLINE A6.0 I I A6.0 w Q
I I
W LENGTH I 4"OCTAGONA\ LEAVE GAPS IN L URE
- z
I 1 J-BOX BLOCKING FOR AIR I I HIP CAP EXTEND METAL ROOF PANEL 3
FLOW I I UNDER TOP CAP
SECTION FRONT VIEW 0 I a
VENTILATION OPENING
AREA OF ROOF CAP ------------ ICE&WATER SHIELD
TOWER PIER LIGHT FIXT.WC1 MOUNTING BLOCK: WIDER HIP COVER IN SHEATHING a a
o 0
ROOF HIP 5/8"SHEATHING Z
O� CV G n
MFR: BORAL A
�o U o � Z w
NEOPRENE BLOCK
MODEL: FLAT TEXTURED CAPSTONE,9" X 20"L o o �, o a ¢ w N
COLOR: "TAUPE" ` a o o U
NOTES: CUT OPENING FOR 4"OCTAGONAL J-BOX
;L
AS SHOWN. CENTER BLOCK ON LT. FIXT.
�3� RAIN SHIELD �5� TOWER LIGHT FIXTURE MOUNTING DETAIL �� ROOF CAP PLAN VIEW �7� ROOF CAP PLAN VIEW g TOWER CAP HIP DETAIL A6 . 0
A6.0/ 6"=1'-0" A6.0/ 1"=1'-Orr
A6.0 3/8"=1'-01, A6.0 3/8"=1'-0" A6.0 1 1/2"=V-0"
07/26/2021
A A NOTE: ALL EXTERIOR WALLS
B TO HAVE R-30 INSULATION a1.0
CD
Cl
U cn o o .y
u
� � •
(8
cd
17 t� l� k o
A3.2 0 Z o o
OPP. - N ri
T.O. PARAPET — — T.O. PARAPET _ _ T.O. PARAPET 17
T.O. PARAPET
22' 4" 22' 4" 22'-4" A3.2 22' 4" 1�
STEEL BEAM STEEL BEAM
RE:STRUCTURAL STEEL BEAM RE:STRUCTURAL 5/8"EXTERIOR GRADE FIRE
17 RESISTANT PLYWOOD SHEATHING
A3.2 I I I I RE:STRUCTURAL AT ENTIRE WALL SURFACE BEHIND
- - SIGN. Q� a
1.
STEEL BEAM CEMENT BOARD LAP SIDING OVER ONE LAYER I 7/8"STUCCO FINISH OVER
RE:STRUCTURAL HIGH DENSITY POLYETHYLENE BARRIER OVER 3.4#SELF-FURRING
ONE LAYER BUTYL RUBBER MEMBRANE
BARRIER OVER 5/8"EXTERIOR GRADE I I GALVANIZED METAL LATH
PLYWOOD SHEATHING OVER ONE LAYER HIGH .,..�
20 CEMENT BOARD LAP SIDING OVER ONE 20 20 DENSITY POLYETHYLENE Q�
20 SINGLE PLY ROOFING I I A3•2 SINGLE PLY ROOFING LAYER HIGH DENSITY POLYETHYLENE A3.2 A3.2 BARRIER OVER ONE LAYER w
SYSTEM OVER RIGID SYSTEM OVER RIGID BARRIER OVER ONE LAYER BUTYL RUBBER BUTYL RUBBER MEMBRANE
A3.2 SINGLE PLY ROOFING SINGLE PLY ROOFING
INSULATION(TYP.) INSULATION (TYP.) MEMBRANE BARRIER OVER 5/8"EXTERIOR SYSTEM OVER RIGID BARRIER OVER 5/8"EXTERIOR V
RE:ROOF PLAN,SHEET RE:ROOF PLAN, SHEET GRADE PLYWOOD SHEATHING SYSTEM OVER RIGID GRADE PLYWOOD SHEATHING
INSULATION (TYP.) INSULATION(TYP.) � U
A3. A3.0 RE:ROOF PLAN, SHEET \N
8"METAL STUD,TYP RE: ROOF PLAN,SHEET 8"METAL STUD(TYP.) ` �1
RE:STRUCTURAL A3.0� A3.0 RE:STRUCTURAL U
JST. BRG. FRONT JST. BRG. FRONT STEEL BEAM. RE:STRUCTURAL v
17'-10" 17'-10"
STEEL BEAM. INSULATE VOIDS AT BEAMS JST. BRG. MID FRONT
RE:STRUCTURAL I I STEEL JOIST(BEYOND) STEEL BEAM.
RE:STRUCTURAL RE:STRUCTURAL STEEL JOIST(BEYOND) STEEL BEAM
INSULATE VOIDS AT BEAMS I I STEEL JOIST(BEYOND)
RE:STRUCTURAL RE:STRUCTURAL
INSULATE VOIDS AT BEAMS RE:STRUCTURAL
R30 BATT INSULATION R30 BATT INSULATION(TYP) 1/2"GWB TO UNDERSIDE OF GWB TO UNDERSIDE
R30 BATT INSULATION OF DECK OF DECK INSULATE VOIDS AT BEAMS
CEMENT BOARD LAP SIDING OVER ONE LAYER _ _ _ _ _
HIGH DENSITY POLYETHYLENE BARRIER OVER 8"METAL STUD -
ONE LAYER BUTYL RUBBER MEMBRANE BARRIER A RE:STRUCTURAL 1/2"GWB TO UNDERSIDE
OVER 5/8"EXTERIOR GRADE PLYWOOD OF DECK HANGER ROD ANCHOR
SHEATHING -2"
SIM. - 13
18 TRIM BOARD TYP A7'0 I I R30 BATT INSULATION(TYP.)
A7.0
RE: EXTERIOR
LIGHT. RE: ELECTRICAL ELEVATIONS
T.O.CLERESTORY I [�T.O.CLERESTORY
13'-6" t 13'-6" LIGHT FIXTURE CMp
L _jSUSPENDED ACOUSTICAL SUSPENDED ACOUSTICAL RE: ELECTRICAL
_Y �
8"METAL STUD TILE CEILING I I TILE CEILING
RE:STRUCTURAL Q
W Z
19 STOREFRONT SYSTEM 28 C)
A7.0 I A3.2 � J
TRIM BOARD,TYP RE: J
EXTERIOR
Q Z
ELEVATIONS 00 Z
11' 0" GWB ABOVE Q LU
B.O. CLERESTORY I B.O.CLERESTORY — _ _ _ — _ I w
11' 0" z W Q
CEMENT BOARD
0
BELOW o w Q O Q
CLG HEIGHT,
� 10'-0" � FASCIA
— — — PANEL — — — — — — — — — — — — — — — — — — — — — — — FFFFFFFFFFFF
SUSPENDED ACOUSTICAL — — — 26 —
�\ TILE CEILING
y 1/2"GWB TO UNDERSIDE B.O. OVERHANG
-- OF DECK
-- B.O. OVERHANG SOFFIT
_j 9' 0"L - - - - - - - - -
TUBE STEEL
BEAM. RE:
A STRUCTURAL
a
U
0
o
I
`m
0
3
STOREFRONT SYSTEM DOWNSPOUT 3
BEYOND
o
TRIM AT DOWNSPOUT
PRE-CAST ADHERED MANUFACTURED ONE LAYER HIGH DENSITY lo
STONE WATERTABLE/SILL TRIM AT DOWNSPOUT
POLYETHYLENE BARRIER OVER
STOREFRONT ONE LAYER BUTYL RUBBER
SYSTEM — MEMBRANE BARRIER OVER 5/8" o O
ONE LAYER HIGH DENSITY EXTERIOR GRADE PLYWOOD 00
POLYETHYLENE BARRIER OVER ONE SHEATHING M
LAYER BUTYL RUBBER MEMBRANE LO
BARRIER OVER 5/8"EXTERIOR GRADE 4"DOWNSPOUT BEYOND 10 PRE-CAST ADHERED r
PLYWOOD SHEATHING A6.1 MANUFACTURED STONE J
WATERTABLE/SILL w
jk T.O. MULLION&SILL — — o T.O. MULLION&SILL _ � T.O. MULLION&SILL _ — — — _ _ — o _ T.O. MULLION&SILL m
11 3 0 5 3' 0" a O �..0
A6.2
Lu w (�
CD w ADHERED MANUFACTURED w
ADHERED MANUFACTURED STONE STONE VENEER Z
VENEERLu
5 Q
cn A6.1 TERRAZZO v�i N
Lu 8 5 FLOOR FINISH _
a A6.1 TERRAZZO a N z
A6.1 FLOOR FINISH E U)
TER ZZO FINISH TERRAZZO 1/2"EXPANSION JOINT CONCRETE SLAB. 5 s m Z 0
FLO R FLOOR FINISH W/SEALANT(TYP) CONCRETE SLAB. RE:STRUCTURAL A U—
RE:STRUCTURAL A6.1
T.O. FLOOR SLAB _ / T.O. FLOOR SLAB — ° / � T.O. FLOOR SLAB — — — — — — T.O. FLOOR SLAB = LO 06 J U
0' 0" ° / 0' 0" 0' 0" a d 4a- ° d
d d �d d W
a - -- -- — — _ - a _ \ Q _d db- LU ILL
- U
CONCRETE SLAB a / W rn
CONCRETE SLAB. J 4
_ — - - a ;< _,a — ° �— Q a U
RE:STRUCTURAL -0.d RE:STRUCTURAL _ _ _ a ° - w Lu
J
d -
a 45 Lu J
Lu
Q Q - Q
III III III IIIJi
o � w
a c=n
o
_ OF:
•
II III III III III III III III III III III III III=
a Digitally signed by R S Day
CN=Robert S Da
c� ,OBERT -/Dyp�ooa0000 s 7 go 2 g,
t°o ENGINEERS PLANIJE htaC�1S C
�p••��n�� I have reviewe i c n.
fJ S Contact Info:This docu nt as men
�[RA.J \.J �i6Ay Day
signed s aW b<o art
//F11111"SS y usfig a Digital S n°ea pi
hi,,cocrosnt are
U •, on enYanta, tin chco t.ur =e ei d
1 FRONT WALL SECTION 2 FRONT WALL SECTION 3 FRONT WALL SECTION T 1r4y
4 WALL SECTION I N � Date.2021.07.26 15 50-ON'BO'
A6.1 314"=1'-0" °• 314"=1'-0" 314"=1'-0" 314"=1'-0" �
a
LAYER OF HIGH-DENSITY ADHERED MANUFACTURED > 07/21/2021
SEALANT&BACKER ROD. 30#ELASTOMERIC SELF ADHERED MANUFACTURED N
o
POLYETHYLENE BARRIER STONE VENEER (MATCH STOREFRONT ADHERING MEMBRANE WRAP 12" STONE VENEER OVER ONE LAYER o
OVER ONE LAYER OF BUTYL I 5/8"EXTERIOR GRADE SEALANT COLOR) UP SHEATHING AND 8"DOWN HIGH DENSITY POLYETHYLENE o 0 0 0 0
RUBBER MEMBRANE OVER Q ALUMINUM STOREFRONT W/ FOUNDATION BARRIER OVER ONE LAYER BUTYL m N N N N N
PLYWOOD SHEATHING. A I - p � c) c) 00
5/8"EXTERIOR GRADE I ' BRAKE METAL TO SPANDREL GLASS PANEL I' RUBBER MEMBRANE BARRIER N N o N
PLYWOOD SHEATHING. IC A D A ER S IL F 0 1 __, ALUMINUM STOREFRONT MATCH STOREFRONT I OVER 5/8"EXTERIOR GRADE 0 0 0 0 0
ABOVE SLAB TO 8"BELOW SLAB. FRAME SEALANT ICE AND WATER SHEILD I PLYWOOD SHEATHING
ALUMINUM GLAZING SEALANT&BACKER ROD.
30#ELASTOMERIC I i� FRAME MATCH STOREFRONT QUARTZ"COARSE CARRERRA" FROM 12"ABOVE SLAB TO 8" I'
1"INSULATED SELF-FURRING GALV. LATH& D
SELF-ADHERING I 20 GA.SS SHEET OVER ICE AND i ° ° SEALANT COLOR SILL BY CABINET VENDOR BELOW SLAB. I °'
TEMPERED GLAZING I ' SCRATCH COAT. EXTEND TO
MEMBRANE.WRAP 12 I WATER SHEILD FROM 12"ABOVE TO 8" / 1/2" 1"INSULATED TEMPERED y 0 Z
UP SHEATHING AND 8" I I BREAK SHARP EDGES FOUNDATION c O
BELOW SLAB. SECURE W/NEOPRENE I I GLAZING 1/2"TERRAZZO WRAP BRAKE METAL PRE-CAST ADHERED STEEL COLUMN _ "'' v)
SEALANT& I MIN.6"DOWN SLAB MANUFACTURED STONE W/R1/8"ROUND-OVER 20 GA. SS SHEET OVER ICE AND � g -L �
RE:STRUCTURAL w � >
DOWN FOUNDATION ---- FASTENERS AT THE TOP AND TEK 1/2"TERRAZZO CONC. SLAB ON �—n �_ WATER SHEILD FROM 12 V w W w
' @ BACKER RODS ` '= ;' EDGE BRAKE METAL TO WATERTABLE/SILL L� T.O. SILL '
SCREWS AT THE BOTTOM 12 O.C. — ( 0 � v� o Q
i VAPOR RETARDER MATCH STOREFRONT — PVC WEEP SCREED, ABOVE TO 8 BELOW SLAB. - 1—
PVC WEEP SCREED, L _ i CONC. SLAB ON ) 5 - o
SIMPSON A 21 OR MIN.22 GA. 3' 0"A.F.F. SECURE W/NEOPRENE m w
° VAPOR RETARDER 3/4" COLOR:WHITE o
COLOR:WHITE SCRATCH COAT. _— CONT. MTL SUPPORT BRACKET _ FASTENERS AT THE TOP AND > w
8"METAL STUDS o CONCRETE SIDEWALK. �� _ - 4- d` : = W/HOLDING CAPACITY 5 LBS/LF. ———————— 1/2"TERRAZZO TEK SCREWS AT THE BOTTOMLu Lu
m a
I CONT. MTL FLASHING W/HEMMED RE:CIVIL °' d = ="a -° - a° °° Y -` _ + - ACROVYN EDGING ,
SIMPSON A 21 BRACKETS SHALL CONC. SLAB ON
° d ° + LANDSCAPING - @ 12"O.C.
1/2"TERRAllO EDGES(HOLD FROM FRONT OF STONE -Q .°- ° -• ad- a _ a ' , a" + MATERIAL BE SPACED AT 16"O.C.OR 2 CASEWORK OUTLINE. °
,d 4 a q _ d_ ( ) RE:SHEET EQ. VAPOR BARRIER LAP HIGH DENSITY POLYETHENE Z Q
1/4"MIN. SET IN A BED OF SEALANT 1/2"EXPANDABLE FILLER d ° a °_ , ,-,•a + + BRACKETS PER SILL PIECE.
cllj
CONC.SLAB ON RECESSED&SEALANTED dy d BARRIER OVER FLASHING
VAPOR BARRIER - - d BRACKETS SHALL BE ATTACHED HSS 8x4x3/16. ;
"' 4"REQUIRED @ GRADE a 4 - a°, ° d m a USING GALVANIZED SCREWS, RE:STRUCTURAL a d d- s° 4"REQUIRED @GRADE
a ° CONDITION a<Q ; a °a .d4': ° "dd d.• PENETRATING STUD MIN 1" a` d- o
d --a a;° a " �_ THICKENED SLAB AT „ ° d° p' d _ 8"METAL FRAMING -a - CONDITION a
da SIDEWALK = a d ONE LAYER HIGH DENSITY 1/2"GWB ° ` °D CONT. MTL FLASHING W/ =a O o N
4- STOREFRONT _ e a d_ °� - ° o Z N
Q _ °^ SEAL WITH SIKAFLEX SL ° _ ;, ° ` " ° d POLYETHYLENE BARRIER OVER ONE ACROVYN a O O O HEMMED EDGES(HOLD FROM � N W o
O O o - ' THICKENED SLAB AT LAYER BUTYL RUBBER MEMBRANE _ FRONT OF STONE 1/4"MIN.) `—'� Lu 7 Z
a, ° < _. 4 GRAVEL o- a a $ ', a' ' ' .- O � w a tYi Q N
= a ,; �Q��Q °a d STOREFRONT ON 5/8 EXT. PLWD SHEATHING R 30 R30 BATT INSULATION A _' a = SET IN A BED OF SEALANT g o �, o a Q w c� N
° 6 Go
°a ° (' ('� POLY FOAM EXP.JOINT A 4 ' :' a . ° ,_
-a d LATH/SCRATCH COAT SIDEWALK
�. ,d•" ° III III III III III III I °
dP ` - ADHERED MFD STONE VENEER WHERE GLAZING FRAME IS FLUSH WITH SHEATHING e''d " =° _ 4° SEAL WITH SIKAFLEX SL
' ' _FOUNDATION.RE:STRUCTURAL
5/8"BITUMINOUS EXPANSION JOINT. A6 . 1
5 PERIMETER BASE DETAIL g SECTION AT STOREFRONT GLAZING 9 SECTION AT STOREFRONT GLAZING AT LANDSCAPING 10 SILL DETAIL KNEE WALL BASE FLASHING IS COLUMNS
• 1 112"=1'-0" 1 112"=1'-0" 1 112"=1'-0"
A6.1 1 1/2"=1'-0" A6.1 1 1/2"=V-0"
07/26/2021
NOTE: ALL EXTERIOR WALLS TO
HAVE R-30 INSULATION
o
8 G F 1 � � U
U cn o o .y
0
oo k U.
00 St
STEEL BEAM
T.O. PARAPET — — — — — — — — T.O. PARAPET �0.4ARAPET
RE:STRUCTURAL
A3 217 STEEL BEAM 17
RE:STRUCTURAL
STEEL BEAM
RE:STRUCTURAL '
_ STANDING SEAM METAL ROOF, RE: 12
A3.2 _
A4.0 ARCH EXTERIOR FINISH I
SCHEDULE � �
CEMENT BOARD LAP SIDING OVER 5/8"EXTERIOR GRADE
ONE LAYER HIGH DENSITY PLYWOOD
POLYETHYLENE BARRIER OVER
ONE LAYER BUTYL RUBBER TRUSS FRAMING, RE: I SINGLE PLY ROOFING
MEMBRANE BARRIER OVER 5/8"
EXTERIOR GRADE PLYWOOD SINGLE PLY ROOFING STRUCTURAL I SYSTEM OVER RIGID
INSULATION (TYP.) � U
SHEATHING SYSTEM OVER RIGID - - SINGLE PLY ROOFING RE:ROOF PLAN, SHEET
INSULATION(TYP.) 13 SYSTEM OVER RIGID
RE: ROOF PLAN,SHEET A3 2 INSULATION(TYP.) U
RE: ROOF PLAN,SHEET �--+
8"METAL STUD 3' v
RE:STRUCTURAL A3.0
R30 BATT INSULATION STEEL BEAM,
RE:STRUCTURAL
STEEL BEAM. RE:STRUCTURAL
INSULATE VOIDS AT BEAMS TRIM BOARD TYP INSULATE VOIDS
RE: EXTERIOR ELEVATIONS I I AT BEAMS
STEEL BEAM.
R30 BATT INSULATION 1/2"GWB TO UNDERSIDE RE:STRUCTURAL O
OF DECK INSULATE VOIDS
AT BEAMS -
o SIGN, BY SIGN I I STEEL JOIST(BEYOND)
CONTRACTOR I I RE:STRUCTURAL R30 BATT INSULATION
13
A7.0 5/8"EXTERIOR GRADE FIRE 1/2"GWB TO,,
RESISTANT PLYWOOD SHEATHING AT I I UNDERSIDE OF DECK
ENTIRE WALL SURFACE BEHIND SIGN
R30 BATT INSULATION --- _____
' T.O.CLERESTORY - ch
CEMENT BOARD LAP SIDING OVER W o
3' 6" 5/8"EXTERIOR GRADE I I
L__ _J ONE LAYER HIGH DENSITY _Y o SUSPENDED ACOUSTICAL PLYWOOD SHEATHING
TILE CEILING I I POLYETHYLENE BARRIER OVER Q
STOREFRONT SYSTEM ALL JOINTS,GAPS,OR SPACES ONE LAYER BUTYL RUBBER 1/2"GWB TO LLI —
LEADING FROM BUILDING/VESTIBULE I I MEMBRANE BARRIER OVER 5/8" UNDERSIDE C) Z
EXTERIOR GRADE PLYWOOD O
SHIM AS REQUIRED TO TOWER SHALL BE SEALED OF DECK
SHEATHING � �
TRIM BOARD,TYP 19 7/8"STUCCO FINISH OVER 3.4#SELF- I I 3/4"PLYWOOD DECKING J >-
RE: EXTERIOR ELEVATIONS A7.0 FURRING GALVANIZED METAL LATH _
LIGHTING FIXTURE, - OVER ONE LAYER HIGH DENSITY I I 0¢0 Z
2X WOOD BUCK POLYETHYLENE BARRIER OVER ONE I I 8" 16 GA.MTL STUDS w Q ~
_ RE: ELECTRICAL _ _ _ B.O.CLERESTORY LAYER BUTYL RUBBER MEMBRANE @ mi U
3/4"PLYWOOD 16"O.C. ¢ W
SINGLE PLY 11,-0" BARRIER OVER 5/8"EXTERIOR GRADE I I z � Q
ROOFING SYSTEM. �R— PLYWOOD SHEATHING 8" 16 GA.MTL z Q
RUN UP WALL 8"MIN. I I STUDS @ 16"O.C. w o Q
15 N
1/2"GWB A7.0 — — CEILING:
2X2 ACT
TUBE STEEL BEAM — — — — —
5/8"M.R.GWB CEILING CEILING,
RE:STRUCTURAL
— — — — — — — — — — — 8"MTL FRAMING @ 16"O.C.
B.O.OVERHANG
9'-01.
10
- - - - -
S FF T L A9.0
28 SOFFIT A ACCENT BEYOND PER
FINISH SCHEDULE RE:
A3.2 SH ET A4 0
EXTERIOR LIGHT FIXTURE.
FIXTURE SHALL BE o
SECURED AGAINST
MOVEMENT/ROTATION. RE: C ff
ELECTRICAL
3
5 \ i PT i
ACCENT TRIM BEYOND, 3
PER FINISH CHEDULE.
RE:SHEE A .0 \
A \ PRE-CAST ADHERED
MANUFACTURED STONEo
c,
WATERTABLE/SILL -
STOREFRONT SYSTEM \
STOREFRONT
SYSTEM \ ONE LAYER HIGH DENSITY
ADHERED MANUFACTURED
�I POLYETHYLENE BARRIER 00
nneN OVER ONE LAYER BUTYL o M
STONE VENEER
RUBBER MEMBRANE
\ BARRIER OVER 5/8"
\ EXTERIOR GRADE PLYWOOD m J
SHEATHING mow�//
PRE-CAST ADHERED m LL
MANUFACTURED STONE
WATERTABLE/SILL o A16:2: - LU
I I
30 / o 0
A9.0
w
/ ow Z
I
� �
w �. � Q
o
N
/ co
w O =
5 I I I TERRAZZO FLOOR FINISH / a :A6:1: : ::: :?t::: ::?::: o CN Z
A6.1 / ADHERED MANUFACTURED E (�
CONCRETE SLAB, s
CONCRETE SLAB / RE:STRUCTURAL STONE VENEER TERRAZZO c m Z 0
-FLOOR FINISH -
LL
Lz RE:STRUCTURAL / — — 1 00 0 J r 1
T.O. FLOORLIT.O.FLOOR SLAB T.O. FLOOR SLAB
_ .. d. ,. ° . d - a _ d, - _ da _ _ 0'-On n - d. a d - a a W W L�
•-d_, "•4•. aq _ - ad - d - - b e - - d' - :q• a a d - - L \
41
1/2"EXPANSION JOINT qy ° b Q W co
-1/2"EXPANSION I W/SEALANT,TYP : _ ti ' e` o W U J
J - Ad ' a a d
J J
zQQ � � Q
W/SEALANT,TYP — —RE:STRUCTURAL r
E � w
- - - E O LL
o w
- - -
o
IIIIII—III— III—IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII—III - -_ -_
— — — q ,• Digitally signed
ert S Da S JDDaQaay�y
El �El El El El DOIII III III III III LpgERT 0-CI9P#9AND PETE MAF F l0 C 0
III III III III III III III III III III III III III III III III III III III III III III III III III I N • . pp Y Reasl SEER have re e� c` n
I� " Dlaytusfi9aal signed
S Contact MI.This cu sn4 r0 bo g<�go Pi
(, of this document are t in e
4� SIDE WALL SECTION t v and sealed and the s eJ��@u9tlhe ri d
1� SIDE WALL SECTION 3 REAR WALL SECTION Date221.07.2615:1 57-0(40-
A16J.2 3/4"=1'-01,
07/21/2021
o
CEMENT BOARD LAP SIDING OVER 7/8"STUCCO FINISH OVER 3.4#SELF-
ONE LAYER HIGH DENSITY FURRING GALVANIZED METAL LATH METAL FRAMING N N N N N
15/16"ANCHOR RE:STRUCTURAL METAL STUDS y o 0 0 0 0
POLYETHYLENE BARRIER OVER OVER ONE LAYER HIGH DENSITY o o � M N N N N N
ONE LAYER BUTYL RUBBER POLYETHYLENE BARRIER OVER ONE � CO CO 00
BOLT HOLE ONE LAYER HIGH DENSITY N D N N o N
It (0 (0 r-
MEMBRANE BARRIER OVER 5/8" LAYER BUTYL RUBBER MEMBRANE 41/2" POLYETHLENE BARRIER 5/8"EXTERIOR PLYWOOD 0 0 0 0 0
EXTERIOR GRADE PLYWOOD II BARRIER OVER 5/8"EXTERIOR GRADE _ -,- '_ ;- : _
SHEATHING II PLYWOOD SHEATHING OVER ONE LAYER BUTYL SHEATHING OVER METAL
BASE PLATE TOP VIEW _ 7/8"THICK 3-COAT STUCCO
( I RUBBER MEMBRANE STUDS
r FINISH IN ACCORDANCE 1 BARRIER OVER 5/8"
AMICO SCREED, II WITH FLORIDA BUILDING - _
II AMICO SCREED,AMMWS-780-780, } PLYWOOD SHEATHING ,t ONE LAYER HIGH-DENSITY cn c p
AMMWS-780-780,COLOR: I I I CODE CHAPTER 25&ASTM _
CONT.8"HORIZONTAL COLOR:WHITE POLYETHYLENE BARRIER OVER ONE 2 "''
WHITE �I I C926 STUCCO"BROWN"COAT, LAYER BUTYL RUBBER MEMBRANE ci •y V w >
STEEL STUD HT. r w w
I @ I LEVELING COAT U)
SEALANT SEALANT UNDER SCREED REQ.'D
I 3'-0"A.F.F. 4"SCHEDULE I 3.4#SELF-FURRING METAL
a ,L N
UNDER SCREED 40 PIPE w I LATH INSTALLED IN -; _ - N m
REQ.'D CONT.8"HORIZONTAL MINIMAL GAP > I '' _ ' MINIMUM 1 1/4"OVERLAP
STEEL STUD @ HT.3'0" Q o I ACCORDANCE WITH I STUCCO SCRATCH BASE y '; w w w o w
FLORIDA BUILDING CODE COAT OVER SELF FURRING o � m a
MINIMAL GAP I A.F.F. I PRE-CAST ADHERED o I CHAPTER 25 METAL LATH — FIBER CEMENT LAP
SIMPSON A 21 OR MIN.22 m 4-1/2"SLEEVE a I SIDING COORDINATE °
PRE-CAST ADHERED SIMPSON A-21 OR MIN.22 GA. MANUFACTURED STONE J I ( z
I = OVER 4"PIPE J
MANUFACTURED I CONT. MTL SUPPORT BRACKET W/ GA.CONT.MTL SUPPORT I WATERTABLE/SILL m I ONE LAYER HIGH-DENSITY I STUCCO FINISH COAT WITH MFR'S CURRENT a
STONE �� I HOLDING CAPACITY 5 LBS/LF. BRACKET W/HOLDING I = I POLYETHYLENE BARRIER I•, RE: ELEVATIONS MIAMI DADE NOA)
ADHERED MANUFACTURED STONE �,
:. .`
WATERTABLE/SILL SIMPSON A-21 BRACKETS SHALL CAPACITY 5 LBS/LF. I VENEER j OVER ONE LAYER BUTYL CONCEALED FASTENER MIN.
SIMPSON A-21 BRACKETS
BE SPACED AT 16"O.C.OR(2) j I RUBBER MEMBRANE BARRIER ;�` ;A' `;.r NO.8-18,0 0.375"HEAD X
ADHERED SHALL BE SPACED AT 16" 2.5#SELF-FURRING GALVANIZED 1/2"THICK
MANUFACTURED STONE I :- BRACKETS PER SILL PIECE. I I } 7/8"TOTAL STUCCO ;° 1-3/4"LONG BUGLE-HEAD a a
VENEER I O.C.OR 2 BRACKETS METAL LATH BASE PLATE I _
BRACKETS SHALL BE ATTACHED ( ) I o N
PER SILL PIECE. I I
THICKNESS SCREW o� z o
USING GALVANIZED SCREWS, — MORTAR SCRATCH COAT AND
I I I A EXPOSED FASTENER MIN.0.075" o z Y
BRACKETS SHALL BE w
PENETRATING STUD MIN 1 SETTING BED 5/8 EXTERIOR-GRADE 3.4#SELF FURRING METAL w
SHANK X 2 LONG CORROSION 2.5#SELF FURRING I I ° a v o
ATTACHED USING ° o �, o a Q
GALVANIZED METAL LATH I I a< PLYWOOD SHEATHING LATH INSTALLED IN a _
GALVANIZED SCREWS, I ONE LAYER HIGH DENSITY OVER 8"METAL STUDS ACCORDANCE WITH RESISTANT METAL STUD FINISH NAIL a o o
MORTAR SCRATCH COAT PENETRATING STUD MIN I POLYETHYLENE BARRIER OVER a (PIN)
BOLLARD COVER FLORIDA BUILDING CODE
AND SETTING BED 1" ONE LAYER BUTYL RUBBER CHAPTER 25. NOTE: BOTH CONCEALED AND EXPOSED FASTENERS SHALL BE
ONE LAYER HIGH DENSITY MEMBRANE BARRIER OVER 5/8" BOLLARD ELEVATION SPACED 7"O.C. MAX.VERICALLY AND 16"O.C. HORIZONTALLY
POLYETHYLENE BARRIER OVER EXTERIOR GRADE PLYWOOD A6 . 2
ONE LAYER BUTYL RUBBER SHEATHING
MEMBRANE BARRIER OVER 5/8"
5 STONE DETAIL SIDING EXTERIOR GRADE PLYWOOD 6 STONE DETAIL STUCCO 7 GENERATOR BOX BOLLARD DETAIL g STUCCO DETAIL TYP. g LAP SIDING HVHZ DETAIL
A6.2 3"=1r_Orr A6.2 1 1/2"=V-0"
A6.2 1 112"=1'4" A6.2 1 112"=1'4"
07/26/2021
STEEL COLUMN CONT.2X P.T.WOOD BUCKS
RE:STRUCTURAL 8"METAL STUDS @ 16" SHALL BE ATTACHED USING 7.8
MIN. R-13 BATT. HILTI KWIK-PRO SELF DRILLING
ACROVYN OVER 1/2"GWB 2 26 INSULATION O.C.TO UNDERSIDE OF 26 SCREWS S-WW 14X20X2 3/4" 26\
I DECK A9'0 PFH#4 WINGS @ 18"O.C. 26 A9.0 a N
6"X 6"ACCESS A9.0 Cl
OVER 1/2"GWB PANEL. 1/4"METAL BRACKET ACROVYN OVER 1/2"GWB __ _______________ �,_ �, Cl
FOR PIPE SUPPORT - ----------- -- 26 l�
R30 BATT INSULATION -- ------ ----------- ----- 4"CA TYP ACROVYN OVER 1/2 GWB ACROVYN OVER 1l2 GWB cy O
„ SHIM AS READ O O
,.,_.,•_,< __,_,,.,_,, _", , , ,_• i _ CAPPED PVC CONT PERIMETER I;, ' ��" "• I
xx
THROUGH WALL A9 0 \
II I SEALANTING ` I
PIPE. -IL---- - CONT. PERIMETER SEALANTING I ''�
CONT. PERIMETER SEALANTING II II SHIM AS REQ'D
STOREFRONT SYSTEM w
- STOREFRONT SYSTEM
STOREFRONT SYSTEM
CONT. SEALANTING,TOP AND SIDES C cd o
SHIM AS REQ'D I I ; j �, / O O
\ �� EXTERIOR WATER
A I SERVICE ROOM \-" SHIM AS REQ'D
- / I MTL.STUD FRAMING IN THIS AREA AS
I REQ'D FOR ATTACHMENT OF
MFD STONE VENEER � I o STOREFRONT SYSTEM TO STRUCTURE
8"METAL STUDS ---------- I I
FIBER CEMENT LAP SIDING OVER ONE
SETTING BED W/SELF I BRAKE METAL OVER ONE LAYER HIGH
LAYER HIGH DENSITY POLYETHYLENE STOREFRONT SYSTEM FURRING, PAPER BACKED / I I , ATTACH STOREFRONT / CONT.SEALANTING,TOP AND DENSITY POLYETHYLENE BARRIER OVER a
8"CONTINUOUS METAL PER NOA/FLORIDA / SIDES ONE LAYER BUTYL RUBBER MEMBRANE
GALV. METAL LATH RUNNER PRODUCT APPROVAL BRAKE METAL OVER ONE LAYER BARRIER OVER 5/8"EXTERIOR GRADE
BARRIER OVER ONE LAYER BUTYL �
RUBBER MEMBRANE BARRIER OVER 5/8" V�
CONT.SEALANTING,TOP AND SIDES I HIGH DENSITY POLYETHYLENE PLYWOOD SHEATHING. BRAKE METAL
EXTERIOR GRADE PLYWOOD SHEATHING I I ;R30 BATT INSULATION FINISHED FLOORING CONT. SEALANTING, I BARRIER OVER ONE LAYER
FILLER ANGLE TO MATCH STOREFRONT.
PRE-CAST ADHERED MANUFACTURED BRAKE METAL OVER ONE LAYER HIGH TOP AND SIDES - BUTYL RUBBER MEMBRANE WRAP SUBSTRATE AND TERMINATE
STONE WATERTABLE/SILL(BELOW) DENSITY POLYETHYLENE BARRIER OVER BARRIER OVER 5/8"EXTERIOR BEHIND STOREFRONT FRAME
FIBER CEMENT ACCENT TRIM ONE LAYER BUTYL RUBBER MEMBRANE 8"NESTED MTL GRADE PLYWOOD SHEATHING. 20 9" O�
RE: EXT. ELEVS BARRIER OVER 5/8"EXTERIOR GRADE STUDS 20 BRAKE METAL FILLER ANGLE TO A7.0 C `
PLYWOOD SHEATHING. BRAKE METAL A7.0 - MATCH STOREFRONT.WRAP NOTE:CENTER STOREFRONT V
FILLER ANGLE TO MATCH STOREFRONT. q SUBSTRATE AND TERMINATE
\10j STOREFRONT PLAN DETAIL WRAP SUBSTRATE AND TERMINATE 2 WATER HOOKUP DETAIL 3 STOREFRONT PLAN DETAIL BEHIND STOREFRONT FRAME �1 STOREFRONT PLAN DETAIL BETWEENICOLUMNS&BLOCKING \�N
( A7.0 BEHIND STOREFRONT FRAME _ ` �1•�
3"=1'-0' A7.0 1 112"=1'-0" A7.0 3"=1'-0" A7.0 3"=1'-0"
CONT.2X P.T.WOOD BUCKS CONT. v Q,
CONT.2X WOOD BUCKS SHALL BE ATTACHED USING SEALANT,TOP
SHALL BE ATTACHED USING HILTI KWIK-PRO SELF DRILLING AND SIDES H.M. DOOR
HILTI KWIK PRO SELF SCREWS S-WW 14X20X2 3/4"PFH BRAKE METAL OVER ONE H.M. DOOR FRAME
R30 BATT INSULATION MC8-SEE STRUCT. DRILLING SCREWS S-WW #4 WINGS @ 18"O.C. LAYER HIGH DENSITY
MIN. R-30 ` POLYETHYLENE BARRIER 2x P.T.BLOCKING
A 14X20X2 3/4"PFH#4 WINGS @
\ FIBER CEMENT LAP SIDING OVER ONE LAYER HIGH 18"O.C. CONT. PERIMETER SEALANT, OVER ONE LAYER BUTYL SEALANT
' DENSITY POLYETHYLENE BARRIER OVER ONE STOREFRONT 1/2"GWB BOTH SIDES RUBBER MEMBRANE BARRIER FRP EDGE TRIM (TYP.)
SYSTEMMEN
LAYER BUTYL RUBBER MEMBRANE BARRIER OVER OVER 5/8"EXTERIOR GRADE FRP WALL PANNEL
8"METAL STUDS PLYWOOD SHEATHING.
5/8"EXTERIOR GRADE PLYWOOD SHEATHING CONTINUOUS BRAKE METAL FILLER ANGLE FRP CORNER TRIM(TY
SHIM AS RE:STRUCTURAL
PERIMETER TO MATCH STOREFRONT.
--- "
REQUIRED _ - -- - - SEALANTING WRAP SUBSTRATE AND
PRE-CAST ADHERED MANUFACTURED _ _
STONE WATERTABLE/SILL TERMINATE BEHIND
STOREFRONT FRAME 1/2"GWB
FIBER CEMENT ACCENT TRIM
PRE-CAST ADHERED FRP WALL PANNEL
SHIM,AS REQ'D MANUFACTURED STONE
CONT.2X P.T.WOOD BUCKS SHALL BE WATERTABLE/SILL METAL STUD WALL
ATTACHED USING HILTI KWIK-PRO FRAMING
SELF DRILLING SCREWS S-WW ADHERED MANUFACTURED
1/2"GWB 14X20X2 3/4"PFH#4 WINGS @ 18"O.C. STONE VENEER OVER ONE R30 BATT INSULATION
CONT. 8"NESTED MTL LAYER HIGH DENSITY M
BRAKE METAL OVER ONE LAYER HIGH DENSITY SEALANT,TOP `= STUDS POLYETHYLENE BARRIER A LU o
CONT. PERIMETER SEALANT POLYETHYLENE BARRIER OVER ONE LAYER BUTYL AND SIDES OVER ONE LAYER BUTYL
RUBBER MEMBRANE BARRIER OVER 5/8"EXTERIOR 1/2"CPVC TRIM
R30 BATT INSULATION RUBBER MEMBRANE Q
GRADE PLYWOOD SHEATHING. BRAKE METAL TO BRAKE METAL OVER ONE LAYER HIGH MIN. R-30 BARRIER OVER 5/8" LU
Z
MATCH STOREFRONT 1"CPVC TRIM
WRAP SUBSTRATE AND DENSITY POLYETHYLENE BARRIER SEALANT AT SILL EXTERIOR GRADE O Q
TERMINATE BEHIND STOREFRONT FRAME 5/8"EXTERIOR GRADE OVER ONE LAYER BUTYL RUBBER PLYWOOD SHEATHING 2EE J
PLYWOOD SHEATHING
STOREFRONT SYSTEM MEMBRANE BARRIER OVER 5/8" BACKER ROD&SEALANT
� >-
CONTINUOUS SEALANTING,TOP AND EXTERIOR GRADE PLYWOOD 1-1/2"MTL STUDS J U)
SIDE SHEATHING. BRAKE METAL FILLER Q Z
ANGLE TO MATCH STOREFRONT. 00 Z
27 STOREFRONT PLAN DETAIL 10 JAMB BEHIND CLERESTORY BSTRATEANDTERMINATE 11 DETAIL AT STONE 12 FRP CORNER DETAIL EXTERIOR DOOR w Q ULU
BEHIND STOREFRONT FRAME
A7.0 3"=1'-01, A7.0 3"=1'0" z 3: Q
4"DOWNSPOUT 7/8"STUCCO FINISH OVER 3.4#SELF-FURRING i \ N
RE: ELEVATIONS GALVANIZED METAL LATH OVER ONE LAYER HIGH Gj CEMENT BOARD LAP SIDING OVER ONE
\ 1 STEEL I-BEAM. LAYER HIGH DENSITY POLYETHYLENE
B SEALANT VOID WITH SIKAFELX DENSITY POLYETHYLENE BARRIER OVER ONE LAYER RE:STRUCTURAL CEMENT BOARD LAP SIDING BARRIER OVER ONE LAYER BUTYL RUBBER
BATT. INSUL. BUTYL RUBBER MEMBRANE BARRIER OVER 5/8" OVER ONE LAYER HIGH CEMENT BOARD LAP SIDING OVER MEMBRANE BARRIER OVER 5/8"EXTERIOR
MIN. R-30 PROVIDE BACKER ROD EXTERIOR GRADE PLYWOOD SHEATHING. DENSITY POLYETHYLENE ONE LAYER HIGH DENSITY GRADE PLYWOOD SHEATHING '
I POLYETHYLENE BARRIER OVER
� LIGHT GUAGE METAL BARRIER OVER ONE LAYER I _
LAP SIDING AS SCHEDULED SIDEWALK 2X4'S @ 24"O.C. FRAMING SECURED TO BUTYL RUBBER MEMBRANE ONE LAYER BUTYL RUBBER STARTER STRIP
RE: EXTERIOR ELEVATIONS RE:STRUCTURAL STRUCTURE ABOVE BARRIER OVER 5/8" MEMBRANE BARRIER OVER 5/8"
STARTER STRIP P.T.2X8 OVER WATER I RE:STRUCTURAL EXTERIOR GRADE EXTERIOR GRADE PLYWOOD
IFLASHING EXTEND 4"UP 6"PVC PIPE CONNECTED TO BARRIER CUT TOP TO PLYWOOD SHEATHING SHEATHING
WALL BEHIND LAP SIDING UNDERGROUND STORMWATER SLOPE AWAY FROM BLDG.
L--L FLASHING. EXTEND 4"UP
i 1' 1" SYSTEM SET FLUSH W/SIDEWALK RE:STRUCTURAL WALL BEHIND LAP SIDING
CONTINUOUS SEALANT BRAKE METAL COPING,TURN STARTER STRIP °
CONT.2X WOOD BUCKS /14 DOWNSPOUT DETAIL @SIDEWALK UP WALL 8"MIN. - 1� I FLASHING CONTINUOUS SEALANT = E
SHALL BE ATTACHED USING ��A .`O� ONE LAYER OF HIGH DENSITY
HILTI KWIK PRO SELF _ 1 112"=1'-0" POLYETHLENE BARRIER OVER
5/8"PLYWOOD SHEATHING -
0 I_
DRILLING SCREWS S WW 6"TRIM.
ONE LAYER BUTYL RUBBER N SEE ELEVATIONS
14X20X2 3/4"PFH#4 WINGS @ UNVENTED ALUMINUM - ,
18"O.C. 4"DOWNSPOUT MEMBRANE OVER 5/8' PANEL SOFFITS THIS AREA (V 3
RE: ELEVATIONS EXTERIOR GRADE PLYWOOD
SUBSTRATE AS SCHEDULED r
SHIM AS REQ'D SHEATHING - - - 3
T.O.CLERESTORY - R30 BATT INSULATION 1 1 2" KIN BAR ( IZ
'4111, SEALANT VOID WITH SIKAFELX - VARIES)
i ud 13' 6" FLUSH FACE EXTENDER 22 GA. - - I - - - CONT.SEALANTo
A PROVIDE BACKER ROD
GALV. MATERIAL(12'-0" o STARTER STRIP
6"FIB R E EN TRIM LENGTHS) - - SOFFIT PANEL I FLASHING
LANDSCAPE N I GENERATOR BOX CONTINUOUS SEALANT 0,CONT.SEALANT,TOP AND J-MOLDS FIBER CEMENT SIDING RE: ELECTRICAL ,
SIDES B.O. OVERHANG I TRIM PAINT TO MATCH 0 0
I = 1X AZEK TRIM HARDIE SIDING °'
8"NESTED MTL STUDS 6"PVC PIPE CONNECTED TO 9'-0" N COLOR:WHITE DRIP FLASHING 00
I I UNDERGROUND STORMWATER SOFFIT PANEL ¢ M
CONT. PERIMETER SEALANT SYSTEM. EXPOSED PORTION OF CONT.22 GA GALV.CLEAT J-MOLDS WRAP ONE LAYER HIGH DENSITYLO
L1 L. PIPE TO BE WHITE (12'0"LENGTHS) POLYETHYLENE BARRIER AND ONE
13 STOREFRONT HEAD 148 DOWNSPOUT DETAIL LANDSCAPING 15 REAR TOWER TRIM ' 16 EXTERIOR SOFFIT DETAIL LAYER BUTYL BARRERUNDERBOTTOMOBRANE 17 DETAIL AT GENERATOR BOX 1g 1 EXTERIOR DEVICE MOUNTING DETAIL
T , ■
A7.0 3"=1'.0" A7. 1 112"=1'-0"
A7.0 1 1/2"=11 A7.0 ! 1 1/2"=V-0" SOFFIT A7.0 3"=1'.0" A7.0 j 3"=11 m L. O
STOREFRONT SYSTEM 11 SIM. CONT.2X P.T.WOOD BUCKS STOREFRONT SYSTEM CONT.2X P.T.WOOD BUCKS STUCCO J-MOLD @ COLOR CHANGE m "
B CONT. PERIMETER SHALL BE ATTACHED USING (n
CONT. PERIMETER A7.0 HILTI KWIK PRO SELF DRILLING CONT. PERIMETER SEALANT 11 SHALL BE ATTACHED USING
PROVIDE END DAMS @ SILL,TYP SEALANT SEALANT A7.0 HILTI KWIK-PRO SELF SEALANT
BRAKE METAL OVER 1/2"GWB SCREWS S WW 14X20X2 3/4" BRAKE METAL OVER 1/2"GWB DRILLING SCREWS S-WW 41/8"
6
SHIM,AS REQ'D PFH#4 WINGS @ 18"O.C. _ U)
R30 BATT INSULATION 6 14X20X2 3/4"PFH#4 WINGS @ •• 0 J
BATT. INSUL. R30 BATT INSULATION 18"O.C. �, 1/2"SLOPE o O <_
CONT.SILL FLASHING MIN. R 30 CIA
SET IN BED OF SEALANT CONT. PERIMETER CONT. PERIMETER SEALANT 1 1/2"MTL STUDS 10'4" CN
SEALANT - o
2 LAYERS OF 1 - T E
CONTINUOUS SEALANT THICK CPVC - - STEEL COLUMN. RE: STRUCTURAL - STEEL COLUMN T.O.TRIM 8 m z w
0 0
B.O. CLERESTORY A - - - A - RE:STRUCTURAL 2 1/2"MTL.STUDS
STAINLESS STEEL o ` 06
CONT.2X WOOD BUCKS -- 11' 0" SCREWS 8"MTL STUDS. RE:STRUCTURAL 1: 7/8"STUCCO FINISH OVER 3.4#SELF- DO 0
SHALL BE ATTACHED USING BRAKE METAL OVER ONE h FURRING GALVANIZED METAL LATH L.L _ _
BRAKE METAL OVER ONE 8 MTL STUDS. RE:
HILTI KWIK PRO SELF LAYER HIGH DENSITY _ ADHERED MANUFACTURED N STRUCTURAL 1, OVER ONE LAYER HIGH DENSITY a Q W
DRILLING SCREWS S WW N STONE VENEER LAYER HIGH DENSITY J POLYETHYLENE BARRIER OVER ONE Q U
14X20X2 3/4"PFH#4 WINGS @ POLYETHYLENE BARRIER ao _ ADHERED MANUFACTURED 1" „� LLj �
OVER ONE LAYER BUTYL `� POLYETHYLENE BARRIER LAYER BUTYL RUBBER MEMBRANE ui
2.5#SELF-FURRING GALVANIZED OVER ONE LAYER BUTYL N o STONE VENEER LLJ
18"O.C. RUBBER MEMBRANE BARRIER - N 30 �) BARRIER OVER 5/8"EXTERIOR o z Z JIII
"? 30 METAL LATH RUBBER MEMBRANE BARRIER Zv 2.5#SELF-FURRING GALVANIZED • Q Q X
4"CLEAR ANODIZED OVER 5/8"EXTERIOR GRADE N GRADE PLYWOOD SHEATHING c 0 /�
TRIM.SEE ELEVATIONS ALUMINUM DOWNSPOUT PLYWOOD SHEATHING. BRAKE A7.0 MORTAR SCRATCH COAT AND OVER 5/8"EXTERIOR GRADE A7.0 METAL LATH j - ,,, 0
METAL FILLER ANGLE TO PLYWOOD SHEATHING. N 2 0 _
SETTING BED MORTAR SCRATCH COAT AND 9'0" o w W
MATCH STOREFRONT.WRAP BRAKE METAL FILLER ANGLE SETTING BED I B.O.TRIM - a CO
CONTINUOUS SEALANT 2"WIDE STAINLESS STEEL ONE LAYER HIGH-DENSITY TO MATCH STOREFRONT. L ONE LAYER HIGH-DENSITY I 1-1/2"MTL.STUDS
SUBSTRATE AND TERMINATE 1"1"
BRACKET WITH SMOOTH POLYETHYLENE BARRIER OVER WRAP SUBSTRATE AND I
POLYETHYLENE BARRIER
EXTEND ROOFING EDGES BEHIND STOREFRONT FRAME 5/8"EXTERIOR GRADE PLYWOOD TERMINATE BEHIND
MEMBRANE UP SIDE WALL SHEATHING STOREFRONT FRAME OVER 5/8"EXTERIOR GRADE OF FLOA
AND UNDER SILL(MIN.8" ' PLYWOOD SHEATHING
VERTICAL ` G CN-RobertS Da
) PRE-CAST ADHERED MFD STONE
OAa y signed ND 011P. ay C
TUBE STEEL 6" 2' 3" 4" WATERTABLE/SILL(BEYOND) I 2 • ; _ Re SIN1EERa have e e c S.
c� LOgERT$i;.- ooa0000ls o z s,
RE:STRUCTURAL �4 1/2" 2' 4 1/2" 51/2" I p� �+ payontact
2'-7" 2'-10" I °d R Day"sm9fa Digital Scu nt as pin pi
/ \ U electronically signed s esyO�B foo�lagRo ert
f his document are
21 aJs
nd sealed annd the s t urerruyyM=e rei d
1g2 STOREFRONT SILL 20 RWC BRACKET DETAIL STOREFRONT 21 TOWER COLUMN DETAIL ABOVE WATERTABLE/SILL % 22 ,1 TOWER COLUMN DETAIL BELOW WATERTABLE/SILL A7.0 on Date 2021.07.2015 03-Oq BO'
A7.0/ 1"=1'-Orr I 3'0"
A7.0 3"=1'-0" A7•0 3"=1'-0" A7•0 1"=1'-0" �_ I T.O.STONE SILL 07/21/2021
PRECAST ADHERED MFDo
N
STEEL COLUMN L STONE WATERTABLE/SILL 0
7/8"STUCCO OVER ONE R30 BATT INSULATION STEEL COLUMN I N N N N N
CEMENT BOARD LAP SIDING I RE:STRUCTURAL I m 0 0 0 0 0
8"METAL LAYER HIGH DENSITY �+ R30 BATT 6 RE:STRUCTURAL ADHERED MANUFACTURED STONE VENEER r N N N N N
OVER ONE LAYER HIGH I 8"METAL 6 I ca
AII FRAMING POLYETHYLENE BARRIER INSULATION o - N N o c�
DENSITY POLYETHYLENE FRAMING CONT.2X P.T.WOOD BUCKS 2.5#SELF-FURRING GALVANIZED METAL LATH
GWB AS OVER ONE LAYER BUTYL CONT.2X P.T.WOOD BUCKS I 0 0
BARRIER OVER ONE LAYER � ' -- o 0 0 0 0
' R30 BATT 2'-3 1/2" 10" SHALL BE ATTACHED USING
BUTYL RUBBER MEMBRANE I SCHEDULED RUBBER MEMBRANE SHALL BE ATTACHED USING - 2'-3 1/2" 10" a�
GWB INSULATION 26 TYP HILTI KWIK PRO SELF DRILLING 3
BARRIER OVER 5/8" � , ����, 5/8" i 26 \ TYP I HILTI KWIK-PRO SELF DRILLING MORTAR SCRATCH COAT AND SETTING BED
I 51/2" 41/2"I SCREWS S-WW 14X20X2 3/4"PFH
EXTERIOR GRADE PLYWOOD R30 BATT EXTERIOR GRADE A9.0 SCREWS S-WW 14X20X2 3/4"PFH A9 0 4" 6" o
BARRIER
#4 WINGS @ 18"O.C. ONE LAYER HIGH DENSITY POLYETHYLENE
SHEATHING INSULATION PLYWOOD SHEATHING SCHEDULED / #4 WINGS @ 18"O.C. I c z
- BARRIER OVER ONE LAYER BUTYL RUBBER o ° O_
i INTERIOR EXTERIOR I MEMBRANE BARRIER OVER 5/8"EXTERIOR o_ w
STARTER STRIP SEALANT - (2)16-GA STUDS
(2)16 GA STUDS &(2) 16 GA RE:DOOR SCHEDULE B B I GRADE PLYWOOD SHEATHING > � w w w
&(2) 16 GA 8"MTL STUDS 8"MTL STUDSX _ 0 U
TRACKS TOP&
FLASHING. EXTEND 4" TRACKS TOP& /
FIBER CEMEN BOTTOM.RE: I 3 5/8"MTL __ -3-5/8"MTL I 22 ~ 0 j ~
UP WALL BEHIND LAP BOTTOM.RE: I fr > w Of
CORNER TRIM 4/S5 ALUM THRESHOLD PER STUDS I A7.0
SIDING 4/S5 - I N
I ADHERED MANUFACTURED STUDS
� I HARDWARE SCHED. 1pli ADHERED MANUFACTURED a m
CONTINUOUS I 2X P.T.WD STONE VENEER STONE VENEER I o
BLOCKING SIM. I
SEALANT N 2X P.T.WD A `�_ I A 2.5#SELF FURRING 2.5#SELF-FURRING I = Z
L I 11 GALVANIZED METAL LATH SIM. GALVANIZED METAL LATH 1-1/2"MTL.STUDS
BLOCKING I SHIM,AS REQ'D °
FIBER CEMENT SHIM,AS REQ'D L =___________ , - a°=• °. A7.0 MORTAR SCRATCH COAT AND 11 MORTAR SCRATCH COAT AND 13
- - A _ I 8"MTL. STUDS a
R - SETTING BED q7 0 SETTING BED
CORNE TRIM
w
n d g
0
CONT. �. ° PRE MOLDED EXPANSION BRAKE METAL OVER ONE LAYER \ ONE LAYER HIGH DENSITY I a
A CONT. �; a ONE LAYER HIGH DENSITY BRAKE METAL OVER ONE LAYE I a a
PERIMETER PERIMETER a° JOINT- HIGH DENSITY POLYETHYLENE POLYETHYLENE BARRIER OVER 5 Fo o N N
4 \ POLYETHYLENE BARRIER I o z
BACKER ROD AND BACKER ROD AND SEALANT ° BARRIER OVER ONE LAYER BUTYL HIGH DENSITY POLYETHYLENE ONE LAYER BUTYL RUBBER A6.1 °' N c
SEALANT FLOOR AS SCHEDULED OVER ONE LAYER BUTYL BARRIER OVER ONE LAYER I o U -- r w o
SEALANT - SEALANT RUBBER MEMBRANE BARRIER \ RUBBER MEMBRANE BARRIER MEMBRANE BARRIER OVER 5/8" I >.o LU CD w a v ¢ N
BUTYL RUBBER MEMBRANE g N, o �, � o a ¢ w C� N OVER 5/8"EXTERIOR GRADE OVER 5/8"EXTERIOR GRADE EXTERIOR GRADE PLYWOOD
HOLLOW METAL FRAME HOLLOW METAL FRAME PLYWOOD SHEATHING.BRAKE BARRIER OVER 5/8"EXTERIOR SHEATHING U a o o U °
5r, 5" METAL FILLER ANGLE TO MATCH PLYWOOD SHEATHING GRADE PLYWOOD SHEATHING.
d
STOREFRONT.WRAP SUBSTRATE 1 1l2"MTL STUDS BRAKE METAL FILLER ANGLE TO PRE-CAST ADHERED MFD STONE °; -° a
MATCH STOREFRONT.WRAP WATERTABLE/SILL _ d
8"MTL STUD TRACK SUBSTRATE AND TERMINATE `'
STOREFRONT FRAME BEHIND STOREFRONT FRAME 8"MTL STUD TRACK 4 •
AND TERMINATE BEHIND ATO
25 HEAD EXTERIOR HM DOORS 26 JAMB EXTERIOR HM DOORS 27 SILL DETAIL 28 TOWER COLUMN DETAIL BELOW WATERTABLE/SILL 2g TOWER COLUMN DETAIL ABOVE WATERTABLE/SILL 30 TOWER LEG SECTION
A7. 311=1'-0" A7. ill=1'-Orr
A7.0 1"=1'-01, A7.0 1 1/2"=114"
07/26/2021
a N
o
u
U cn o o A
5
A7.1
N O O k u
00 Wzl,
CIS
3/8"ALUM. " . -
1"x 3"x 1/8"6063 T52
BRACKET WELDED 2 RECTANGULAR ALUM.
TO LADDER TUBE
A7.1 2-1/2"SERRATED ALUMINUM •�'�,
TREAD(6005-T5)
U
PLAN LADDER
3 V�
A7.1 3/4"=1'-01,
CONCEALED LAG BOLTS WITH 7"MIN.
SPLICE PLATE FLAT WASHERS
(TYP.)
LADDER BRACKET.WELD A C-0
PRE-FABRICATED TO UPRIGHT AT MAX 24" _ LU o
MITRED CORNER O.C.VERTICAL SPACING
---------------T.O. PARAPET-� 2 ---------------- L Q
- W T.O. PARAPET Z
2x2 22 6 A.F.F.
WRAP TRIM ALUMINUM A 22'-6"A.F.F. Q
FLUSH WITH LADDER RUNGS AT V-0" ANGLE 3-6"
PROVIDE HOOK&CHAIN
STUCCO O.C.VERTICAL I = GUARD BETWEEN PARAPET OPENING J
SPACING o RAILING ON ROOF SIDE Q Z
Ams 2 aSTUCCO J MOLD _ _
o w �� ALUMINUM GRATING - Q LU
ALUMINUM BAR A7.1 � t 0-
J LADDER PLATFORM
J_
: END TRIM GRATING - 0 c� ¢ L1J
¢ TOP LANDING z � Q
LADDER; t? Lu HOOK&CHAIN GUARD
PLATFORM TOP Q , BETWEEN RAILS ON z Q
- G� J o ALUMINUM ANGLE 2' 4" EQ I ROOF SIDE OF LANDING _j o
1" 1"
7/8"STUCCO FINISH OVER 3.4# LANDIN1. -___ I M FASTENED TO HORIZ. O EQ. N
- SELF-FURRING GALVANIZED LADDER FRAME cC
METAL LATH OVER ONE LAYER (BELOW) i A HOLD VERTICAL
HIGH DENSITY POLYETHYLENE - M
a BARRIER OVER ONE LAYER BUTYL PLATFORM FRAME ~ OF ROOF FOR FIELD A
RUBBER MEMBRANE BARRIER - ADJUSTMENTS — — FOLD BRAKE METAL MTL GRATE PLATFORM
OVER 5/8"EXTERIOR GRADE 2'- T.O.GRATE FRONT FLAP AROUND
PLYWOOD SHEATHING.WRAP ,�8' 7"A.F.F. AND TOP FLAP OVER q
STUCCO EDGE OF
ROOF
SAFETY CHAIN AT o o o o o /
PARAPET. REAR OF LADDER w o o T.O. PLATE 0.G AT
g LADDER ACCESS COPING L` J - Z ---�8'-1"A..F.F.- - - ------- 18'-7°A.F.F.
1'-8 1/8" `fl T.O. PLATE
SKID �' i 8 18'-1"A.F.F.
_ o
3 1/2"PLATE I A7.1
I OPP. 1 SEAM BRAKE METAL ON BOTH
4 LADDER PLAN @PLATFORM FRONT "1
SIDES OF PARAPET OPENING.
(DO NOT CUT AND FOLD 3
VIEW OF PROVIDE ROOF WALK- 5"PLATE I 3�r a A BRAKE METAL BY HAND o
A7.1 1"=1'-0" SKID WAY PAD BENEATH SKID` I 2 /2" WALL BRACKET - ) 3
ALUM.COPING CAP W/20 / NO TOP FASTENING
GA.CLEAT AND THROUGH PARAPET
CONCEALED SPLICE CAP m 1' 8 3/4"
PLATE,COLOR:AS I o A o
SCHEDULED SEE WALL BLOCKING I N a
Itt,
DETAIL FOR LADDER A 1'-6"MIN.
MOUNTING I o
MEMBRANEWRAP ROOFING DETAIL
00
BENEATH CLEAT I WALL BRACKET -— -— —-— o
LO
8"METAL FRAMING co
WHITE SINGLE PLY ui
ROOFING MEMBRANE I mow�//
7/8"STUCCO FINISH OVER t EXTEND CONTINUOUS METAL FRAMING RUN I o m LL
3.4#SELF-FURRING t' UP AND UNDER q
VERTICALLY @LADDER I 3 - O
I PARAPET COPING SUPPORTS
N
GALVANIZED METAL LATH - t � yp. A7.1 i -
ONE LAYER HIGH DENSITY I (n
POLYETHYLENE BARRIER j
I I WALL BRACKET
OVER ONE LAYER BUTYL r —-—- -—- -------
RUBBER MEMBRANE "f
BARRIER,WRAP OVER r�3 a Q
PARAPET t I N
I - O J
5/8"EXTERIOR GRADE 1 I o N
PLYWOOD SHEATHING t IN LINE W/EACH LADDER BRACKET AT EACH LADDER BRACKET INSULATION AND � N s
I. CONNECTION POINT, PROVIDE(3)2X6 CONNECTION POINT, PROVIDE 2"THICK INTERIOR WALL I m Z
t ' WD STUDS BETWEEN(2)6"MTL WALL BY 02-1/2"SOLID ALUM. STAND-OFF W/ FINISH NOT SHOWN I �
STUDS.RUN 2X6 FROM FIN. FLR.TO TOP HOLE FOR 01/2"LAG SCREW. SEAL ALL FOR CLARITYui
I WALL BRACKET -— -— —-— - 06
Q
j OF PARAPET WALL. FASTEN WD STUDS 00
AROUND BETWEEN ALUM.& PROVIDE(3)0.125"THICK SQUARE LLI N
TOGETHER @ 6"O.C.VERT.W/16d STONE/THIN BRICK - ALUM. BUTT HINGES W/STAINLESS
NAILS.ANCHOR THROUGH EACH MTL , 1 STEEL PIN,SPUN ON BOTH ENDS, Q Q U w
STUD INTO WD STUDS I A7.1 _ �NO HOLES, FINISH SAME AS o w Lu
I COVER.WELD LEAF TO LADDER 0 LLJ
I "I SIDE-RAIL&OTHER LEAF TO a z Z J 0
01/2"X 5-1/2"STAINLESS 2"xl"LADDER RUNGS r � � ~
LADDER SIDE OF COVER PLATE Q
STEEL LAG SCREW&S.S. (KNURLED)AT 1'0"O.C. I w H J
g PARAPET CAP DETAIL @ LADDER OPENING WASHER VERTICAL SPACING 1 0 Lu
WALL BRACKET a co
A71 3"=1'-01, --—-—-—- - -
5 WALL BLOCKING DTL
A7.1 1 112"=1'-0" LADDER BRACKETS: m OF F
WELD HINGED ALUM. LOCKABLE
1/4"THICK WELD TO ' - \ �� `OA
UPDRIGHTS AT MAX 24" I o SECURITY COVER. 1/4"THICK //q/ \�\ �
I �I 6061-T6 ALUM. PLATE W/ G ERT Digitally signed S Da Da
O.C.VERTICAL SPACING // LOB Pj= J�D0000016 0 2 s,
SMOOTH EDGES. POWDER _ o=CUCI AND PETE � o
/ 1 ti ENGINEERS PLAN ea S
COAT TO MATCH PARAPET / 0 I '^y��J V Re...Inelet This documart ��
CAP COLOR / .0 �� ��,! Day usfi9 al Digital S g �. n pi
WALL BRACKET / - - ofthisdocumentare �rwzsi e
________ _ _ _ / O / L C and sealed aad the s re�u�e ri d
/ U on any elgot�Qnic co i p
Date:2tl2?gl' .2615: 56-CMO'
1/2"X 3-1/2"STAINLESS w
7"MIN. 30"CLR
STAINLESS STEEL LAG I
PRE-FABRICATED BOLT WITH FLAT I / \ / a .r -
MITRED CORNERS , - z --% °' 07/21/2021
WASHER(TYP) I LADDER GUARD = N
N POWDER COAT / N
WRAP TRIM FLUSH WITH m / O
THIN BRICK MATCH LADDER OLOR. o 0 0 0 0
I N ++ N N N N N
WALL BRACKET
N N O N
I O O O O O
PROVIDE ALUM. HINGED HASP 3
2-1/2"DIAM SOLID j ON LADDER SIDE OF COVER m
— SEALANT / ALUM. STAND-OFF W/ I AND HOOK WELDED TO
HOLE TO RECEIVE 1/2" I o o p
DIA. LAG SCREW I N LADDER SIDERAIL TO RECEIVE c ., 0
PADLOCK. FABRICATE HASP � g
r*� 1 -9 3/4 > N CD
FROM SAME ALUM.AS HINGE. rn 0 w w w
cn
16
GUARD - FABRICATE PADLOCK HOOK 16 0 ❑
`� FROM 1/4"ALUM. PLATE _ m
ROOFING MEMBRANE 31�ti I WALL BRACKET — — ❑
E w w � w
o m
1' 3" 1' 3" o o Z ¢
i o
7' I CLR. CLR. M
REQUIRED CLEAR
FOLD FRONT FACE OF m
BRAKE METAL AROUND I WIDTH, EACH SIDE, FOR
VERTICAL CLIMBING
FOLD TOP FLAP DOWN 9/16"DIA. SPACE a IF s o N N
OVER BRAKE METAL �I Z o, O
N T.O.SLAB }o LU w N a Lu
c� ¢ N
SPLICE PLATE 0' 0"A.F.F. _
NEAREST PERMANECLEAR DISTANCE NT 0 o a _
p=° O N H O Q ¢ w (D N
PROVIDE WALL CAP AT OBJECT ON CLIMBING SIDE OF', ` a
LADDEMFDI'BRAKE
G PER N
LADDER
DETAIL0 NOT A M
CUT AN 3/8"THK.ALUM.
METAL BY HAND. BRACKET A7 . 1
7 LADDER OPENING DETAIL 6 BRACKET DETAIL 2"' LADDER SECTION FIXED LADDER ELEVATION
A7.1 /
A7.1 3"=11-011 A7.1 j 314"=1'-0" 3/4"=1'-0"� /
07/26/2021
C
a N
o
U
U cn o o A
"oG u".!
CS
oo U
00 '03
Cd
REAR VESTIBULEv„ v'
FLOOR: MAT OVER TERRAZZO
V U
U
------------- ----------- V�
O DS DS DSO O O O DS
1 Ll
O ® O O O
°
Pi
WATER SERVICE - ACRC MEN'S RESTROOM ELECTRICAL ROOM STAGING
\ WOMEN S RESTROOM
\ - FLOOR: EF-1 FLOOR:SEALED CONCRETE 17
ROOM FLOOR:
FLOOR: EF-1
FLOOR:SEALED CONCRETE CO2 P2 FRPC
P6 21 T1 20 A8.2 18
21 M1
A9.0 GT1 A9.0
CT3 -----
- 19
P6 P1 EF 1
GT1 ACRC
FRPC
CT3 EF-1 CD13 :001 W o
E__ E o�
--- -- ---- �-- --- 16 A8.2 14 WASH ROOM LU LU Q
r - -- - -- -I IMG1 1 14 FLOOR:TERRAllO WALK-IN FREEZER � Q WC3 TYP CORNER A9.0 --------------- � O
15 FLOOR: INS MTL PNLS
GT2 I _ I � FRPC �
I GT2 I L � @ FRP I — J
I I
RETAIL WALK-IN I ISL1 - - -L FRPC T1 DS U)
REFRIG. I STAINLESS STEEL J L O m Z
II A W
FLOOR:TERRAZZO - _ _ ° w Q
18 12 A8.2 10 z Q
a ° z
�-� z Q
J A9.0 11 w o Q
I w 11 O v CO
w CT1 N
cn
I U cn
LU
Q FOOD SERVICE 6 U I
r771
WALK-IN REFRIG.
U' o o FLOOR:TERRAllO I FLOOR:TERRAZZO
T1 8 A8.1 10 L T1
0 0
I II I
I II I
I 5 TYP CORNER
- @ FOOD SERVI
26 FRPC SSTL 18
I_ 20 TILE
J A9.0 q 4'-0" A9.0 A9.0 N
CTI
P1\/v ° ---- ---------
4 ACRC
�\ ISL2 T1
DELIVERY VESTIBULE 3 A8.1 11 1 i CO CN
> CT1 _
\ FLOOR:TERRAllO 21 I � 3
I 26 a W
2 J A o 3
I II I
A9.0 I I I
24 A8.2 22r--- I 0 e
FRPC I DS o
I DN
T1 23 I o
A I o
w
w I
--- ---------------------------------------------------------
COFFEE
O
Q L - FLOOR:TERRAllO _ co
- - ------------------------------------------------- -- ------ -
z T1 L0
J
J
SELF SERVICE - - - oi5
I ' 'T W
WALK-IN REFRIG. i v 00
FLOOR:VF1 OVER TERRAZZO Q
19
RETAIL AREA I I I I
FLOOR:TERRAllO WC3 A9.0 ( N O
L
T1 VNR2
vJ
4A
, III 7 _A8.1 9 � I � w II �
o N J
1 m N L.L.
w
I I \ I o I 8 W z
CV LL
WC3 4B LO 0
N OO 06
ACRC J J
V a L.L W W L-L
o ASSOCIATE (:A8.1APRc i Q w
_U Q U =
FLOOR:TERRAllO I 1 ( �QO DS (w'� (_�
MFRPC I R_ 8 < < ILLZ — J
�. a z
0 20 ROLLER SHADE 2 ROLLER SHADES 12 ROLLER SHADES O� / FOR STAMPED CONCRETE, Q W z
0-1 NO O O l / SEE SHEET Al1.0 E Q LL w LU LL
w
22 A8.3 19 H FOR OUTDOOR SEATING
a
LAYOUT,SEE SHEET EQ1 N
D DS S N
21 II �
Fto
G.C.TO PROVIDE AND INSTALL �c�G-�F•...
SHADES AT ALL STOREFRONT
GLAZING BELOW IV-0"AS PER G Digitally signed by R Day
gERT Robert S Da Q
��,t7�M��� D0000016 0 2 9,
Q 15 SPECS. MOUNT ON INSIDE OF N LO_ bocuHACIANDPETE C
ENGIN€ERS PLANK C4 S
OPENING. RE: DETAIL 9/A3.1 p.� • ' Reason:Thsdocument ��
U)
(TYP.) f� J S [���/Day uoq;g a signed an afeQ o ert
06 Day us g a Digital Sg n pi
of this document are Wer2l�si e
7 A8.3 14 J U t C and sealed aad the s re8u e n d
�o Q
16 NOTE:ROLLER SHADE FASCIA I on any ele�otrQnic co i p
T on a 2021.tr m 15: :40-C�00'
M1 COLOR TO MATCH STORE --- -
2 FRONT(TYP.)
OFFICE Z 07/21/2021
FLOOR:TERRAllO ACRC 4 A8.3 1
FRPC P1
T1 o
� N N N N N
———— —————— ———— — ———— —- N N N N N
(2)ROLLER SHADES (2)ROLLER SHADES (2)ROLLER SHADES ~ 3 LINE OF PORCH G N N o N
o L - L L L L L x OVERHANG ABOVE o 0 0 0 0
DS DS a D
I K m
t
I c z
y
L--------------------------------------------------------- c O
ci 0
0 w W w
G.C.TO PROVIDE AND INSTALL °' °' N p
SHADES AT ALL STOREFRONT N m w
GLAZING BELOW 1 V-0"AS PER
SPECS.MOUNT ON INSIDE OF s 0- a m a
OPENING. RE: DETAIL 9/A3.1
6
(TYP.) A z Q
rD
NOTE: ROLLER SHADE FASCIA
lt
n m
COLOR TO MATCH STORE
r
FRONT(TYP.)
FINISHED FLOOR PLAN ¢ 8 o
oaZ �,
0 0
L t5 U oUj
Z Y
p o O C14 H O Q Q W (D N
U— w Q d' 2
' d U
A8 . 0
07/26/2021
GWB TO COVER INSTALL WINDOW SHADES AT "Thank You"BANNER SIGN EXIT SIGN
SPANDREL WINDOW. STOREFRONT. (TYP) Q, )1,2
"Thank You"BANNER SIGN
y 10
A7.oWT-1At4
OP1 WT 1 P1 P1 WT-1 WT 1 A �N b � V
P1 Thardcvoar P1 P1k U
-------- ---------- -------- --
---------- 0 Cc
----------- - -------- --------
- ----------- ----------- P1 WT-1 WT-1 ACRC p � O o
----------- -----------
WT_1 IN V1 A-I fZl w
^ � ACRC
II I I II I � FA HORN/STROBEII I I II I I I I
-- ---- ----------
WT-1 ACRC
I I I FA HORN/STROBE I I I I I I ACRC
FASA = / N
------- � � ---------- ----------- 16 L---------- BOOR ISL1 = ��
TACTILE EXIT FA PUL STATION O
SIGN (TYP.) 9 5/8" 3'-0 3/8" � P6 OPEN TO
FA PULL STATION _� FRAME RETAIL CIS
QUAD � ALUM. PANEL OVER o v A = A BEYOND
0 4 �/ �j U` SPANDRAL BY /
ail
ACRC RECPT Ago �/ // �/ // STOREFRONT r, /
MANUFACTURER, (2)2x6 / y
SEE DETAIL 16/A9.0.
�, BLOCKING Q]
DUPLEX DUPLEX ACRC DUPLEX ACRC ACRC ACRC RB1 U0
RECPT RB1 RECPT. RB1 RECPT RB1 RB1 RB1 RB1 w
RB1
1 CIO
INTERIOR RETAIL ELEVATION 25 v
A9.0 2 ALCOVE ELEV. 3 ALCOVE ELEV. 4 ALCOVE ELEV. 11 ALCOVE ELEV. \�
A8.1 1/4"=1'-0" A8.1 1/4"=1'-0.. A8.1 1/4"=1'-0" A8.1 1/4"=1'-01, A8.1 114"=1'-01, ` �1
U
GENERAL NOTES V
DASHED LINES 6
1. USE RB1 BASE AT ALL CABINETRY.
"BEER COOLER"SIGN INDICATE BLOCKING A9.1 2. PROVIDE SCHLUTER STRIPS AT TILED CORNERS AND AS NOTED ON THE PLANS&ELEVATIONS
7 FOR FOLLET.
PER SPECIFICATIONS.
3. ALL HALF ROUND WOOD TRIM SHALL BE PAINTED P-1, U.N.O.
\ WC3 GT2 WC3 P1 P1 4. MITER CUT ALL TRIM-NO BUTT JOINTS.
P7 PERP. 5. PROVIDE CORNER COVE BASE AT ALL CORNERS.
5 6. NO FINGER JOINTED WOOD TRIM.
P7 .0.SOFFI
GT2 A9.0 7. REFERENCE SHEET E01 FOR SPECIFIC EQUIPMENT IDENTIFIED HERE-IN.
WC3 T.O.SOFFIT P7 - P1 PERP.
FJ�
IRE ALARM
P7 - �`
WT 1 GT2 _ T.O.SOFFIT P1 HORN/STROBE FRPC
T.O.SOFFI - -- _ B.O. SOFFIT _I SSTL
cD \ / CT1 CT1 CT1 FRPC
C.I N CT1 CT1 \ / ACRS RETURN WALL
SELF SERVE BEVERAGE \ / INTERIOR STOREFRONT GLAZING LEGEND
27 - v / /'
ACRC � ' � AREA = m � � DOOR
RTU A9.0 p A / // B32 12"X18"
® 0 IMG1 -_--= o OPEN TO BACK OF \ \ / OT 1/4"TEMPERED GLASS
SENSORS "r n _ ACCESS
2'-0 2 5 A m M I FOOD SERVICE
RE: MECH TRIM KIT QA - / OPEN TO FOOD
I / \ il SERVICE, PANEL W o
ALUMINUM PANEL BY STOREFRONT MANUFACTURER OVER
__ _ O7
IF Y_
/ \
/ \ I / � \ SPANDREL. RETAIL SIDE ONLY.SEE 16/A9.0.
o v B24 CL Q
N / \
// \\ NOTE: REFERENCE EXTERIOR ELEVATIONS FOR W Z
/ \ EXTERIOR GLAZING SCHEDULE � Q
RB1 ISL1 RB5 RB5 P8
17 RB1 4 SPECIAL PURPOS RB3 G4 J
RB1 FRAME RECPT.
A9.0// A9.1 SCHLUTER STRIP,TYP ALL
4A INTERIOR RETAIL ELEVATION - FINISHES TILED CORNERS. RE:20/A9 5 FOOD SEVICE ELEVATION B30.2 1.NOT ALL TILE, GROUT AND SILICONE SEALANT FOR FRP AND TILED AREAS TO BE SUPPLIED BY WAWA m Z
A8.1 1/4"=1'.0" A8.1 1/4"=1'-0" VENDOR AND INSTALLED BY GC.ALL MASTIC AND THIN SET MORTAR TO BE SUPPLIED AND INSTALLED LU
CENTERLINE OF ICE/FREESTYLE BY GC. LU �
MACHINE(TYP.) 2. ALL FINISHES INSTALLED BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. z W Q
wQoQ
LIT SIGN (6)SOFFIT HUNG DATA AND RECEPT.TYP(6) N
MONITORS SEE DETAIL. SEE DETAIL 3/A9.1
® _ �DIGITAL H DIGITAL E DIGITAL �DIGITAL H DIGITAL DIGITAL A
MONITOR MONITOR MONITOR MONITOR MONITOR MONITOR
DUPLEX
RECPT
STAINLESS STEEL FIRE ALARM/
o END CAP,TYP. HORN STROBE o
SELF SERVE BEVERAGE _
DATA AREA -=- PROVIDED BY
RECPT CABINETRY MFR ACRS \ /
❑ L� ❑ 43"DIGITAL vv //� / o
CUP C20
TACTILE EXIT MONITOR 11 B1.2 \ / / -DOOR
DISPENSER w
SIGN(TYP.) - - -I \OPEN TO FOOD
O O E _=EQ 'v SERVICE ❑ OPEN
O b SPECIAL PURP 3
O O O RECEPT
o _ IIIIIIIIIIIIIII Ir / \
❑ ❑ ❑ � ° �� FRAME / \\ U
0
0
C28 C28 MW17.1� C21 C23 MONITOR TO HAVE 1 B19 B9.1 B44 B19 RB5 B21 F5 0
C22 C22 5 CLEARANCE ON ALL F5 PURPSPECIAL F5 619 A C)
A9.1 I S B21 B21 00
DUPLEX a (o
4B INTERIOR RETAIL ELEVATION - EQUIPMENT RECEPT
6 FOOD SERVICE ELEVATION
EQ EQ 6'-10 1/8" O
DASHED LINES INDICATE PROVIDE 1/4"HARDIE DASHED LINES INDICATE
BACKLIT LOGO SIGN. 2X6 BLOCKING BACKER BOARD OVER 2X8 BLOCKING FILLER PANEL BY REF. A U)
SEE DETAIL 11/A9.0. GWB WHERE INTEROR CO.TO MATCH z
STONE OCCURS. III
ADJACENT FINISHES o 0
c 0
N
WC3 WC3 Q
WC1 A WC3 PERP. � WC3 _
P7 w
--- - o TnTLF D ° T.O.SOFFIT
DUPLEX RECPT. oo $ m
o
� o0 0o WT-1 P7 RE. 12/A9.0 LL z
_ ACRC FOR CT1 m w
47 ACRC p GT2 P7 MOUNTING a
T.O.SOFFI HEIGHTS � � W O
❑= a Q W -
INTERIOR STONE ADHERED TO
Q U
GWB PER MFR'S REQUIREMENTS. W5 R3 ' ACRC ACRC W
DOOR / / / / / / Q W LU LU
DOOR
� � Q W �
Z
i� I ti O LU
0 � � o � w
ACRS
SOAP AND
DUPLEX DOOR P6 N
P6 PAPER TOWEL
RECPT. / FRAME DISPENSER. FRAME
e
Nil 1W6 b OF Ftp�
a Digitally signed b R D
RB1 OUTLINE OF CIGARETTE P8 RB1 ISL1 DUPLEX ,� G g v g v
AND TOBACCO CASES. RECPT. LpgERT _ �
D0000016 0 2 9,
RB3 RB5 RoberlS Da
FRAME RB5V_w�
o=cur IANDPETE NA I C
RE: 1/EQ1. y ENGINEERS PLANIk Ca S
Reason:This document 6e
electrogqicslly signed pn aaJJee,,QQt�o art
06 �Rbb 'S ��Day usfig sally
S g �!�rifitd pi
.� of this document are �der*l s
7 INTERIOR RETAIL ELEVATION g FOOD SERVICE ELEVATION L`O C and sealed a.d the s' re ui2e ri d
U on any ele�ot�Qnic co p
Date:2021.1tl.26 15: :45-0w0'
d
a
a
2
07/21/2021
WINDOW SHADES
0
AT STOREFRONT. N N N N N
s y 0 0 0 0 0
- DASHED LINES WT-1
++ N N N N N
A2.0 INDICATE(2)2X6 m p
BLOCKING It 0 0 0 0
I� CO M O
� N N O N
WC3 WC3
` P 1 l a�
EQ EQ / �/ m
PERP. /
\/ 0
_ _ � WC3 � c O_
c Fb
o -
P1 m y E w F_ w
O T6oan<Yoat d y N (n O U
P1 WT 1
- ------- - --- ----- -------- CT1 G - w -
II 0 w > w
N
II IIII I II / B42.2 G2
04
W6 ACRC P1 DUPLEX V3 O � z Q
DUPLEX O WALL BEHIND ----- ---------- ---------- -------- RECPT. O
RECPT. / EQUIPMENT '4 / / B12.2 =N
_ O TACTILE EXIT �
m 3
SIGN(TYP.) a m
a
o
P1 ACRC _ -_=- ¢$ p o
Op a Z
DOOR \ C3.4 C3.3 =LL ~ o w
ALCOVE P6 = DATA OT ' LU CD
o � W o �' ¢ w aU'
RECPT. o 5 a N o U
FRAME
B28.2 ACRC
RB1 RB1 RB1 ACRC ACRC 25 RB5
RB1 A9.0 RB1 A8 .
g INTERIOR RETAIL ELEVATION p FOOD SERVICE ELEVATION
A8.1 1/4"=1'-0"
07/26/2021
W
In.
N
CD
I
o
0 N o
U cn o o .y
TILE TYP FOR ALL WALLS. PROVIDE FIELD TILE(CT3) �10 w � �% I
RE:TILE PATTERN
BEHIND MIRROR. ENSURE �o "0 10
SCHEDULE, DETAIL 26/A8.1 THAT MIRROR COMPLETELY N g � �? 0
CONCEALS FIELD TILE GT1 FA HORN/STROBE �4 r- r- o
p N� Oo lk' U
CD 7_1
11 g 8 8 3" 3"� / 12 le i N V1� a W. w
14 8
1' 6" 4' 6 1/2" 4' 6" 1' 6" 1'-7" GL 4'-41/2" GL 3'-8" q1'-41/2" I 14 -I 1 \ 4 2" I I I I 4 2" \ \ ACRS rA
6.. . 3 I / p .. 3 4 \ DOOR �
0
` I 13 3 ®� 6 13
I�� I . 0 5 13 0 - P8
II
13 ® 1 � ® 13 � i ® � 2 I 1 I ` 15 0
9 1 i 9 w 13 i- -a- - -- - 7� - 7 16 7 / to
6 , REAR VESTIBULE 6 _ 2 2 / b
i . ' T CLR FLR 15
F7
GENERAL NOTES
_"
4 7A 3 _ �, SPACE S 2 .�
i 4 7A 3� i 17 � i "' 30"X 48" 9 9
CLR FLR I I ; i to
14 SPACE I I 2 7 14 8'-4" i 1 � 2'-61/2" 1.ALL DIMENSIONS SHALL BE TO FACE OF FINISH U.N.O. PL 1 29
2 60"X 56"1 1 CLR FLR I I i A8.2 ` mo w
SPACE 1 5 9 A8.3 6 CLR FLR CLR FLR i 2. INSTALL A BEAD OF CLEAR SILICONE AROUND ALL TOILET SENSORS
„ i i S X 48" SPACE 'SPACE i AND ESCUTCHEON RINGS. V
___________ cn
�' 41/4_��_____16 4 -63/4 8 ( , _ ? 6o"X56 3o,x48'_--- 1 16 BARRIER FREE NOTES 2 WOMEN'S RESTROOM ELEV. 3 WOMEN'S RESTROOM ELEV. 4 WOMEN'S RESTROOM ELEV. 5 WOMEN'S RESTROOM ELEV. \�
2 8 BELOW- A8.2 114"=1'-0"
A8.2 1/4"=1'-01, A8.2 114"=1'-01, A8.2 1/4"=1'-0" ` �1
BELOW 16 --- 10 10 MEWS RESTROOM - 8 10 TOILET ROOM TO COMPLY WITH ALL BARRIER FREE U
_ DESIGN REQUIREMENTS INCLUDING BUT NOT LIMITED T0: I'll
\ �-•;
� 1 CLR FLR i /ice �3 A8.2 5- - i � 5 \\ 'CLR FLR v
SPACE i / 5 \ 12 12 /6 \ 'SPACEL A. GRAB BARS :TOP OF GRIPPING SURFACES ON GRAB BARS WILL
30"X 48"i / \ 4 \ i30"X 48" BE 33"-36"ABOVE FLOOR AS SPECIFIED ON SHEET AC1
i I � I I li
i I I 10 7 I A8.2 9 O° Irw
B. MIRROR: (1)24 X 36", BOTTOM AT 40"A.F.F. MAX.AT EACH
I
'1 4 3 BELOW 7 LO / LAVATORY.
\ // 13 A8.3 11 \8 16 // C. LAVATORY: RIM HT.34"MAX.A.F.F; BOTTOM OF APRON 27"MIN.
WON�fN S RESTROOM / I \ BELOW / 4
i � i A.F.F. LEVER HANDLES ON FAUCETS, IF APPLICABLE. INSULATE HOT11 FA HORN/STROBE PROVIDE FIELD TILE(CT3)
WATER SUPPLY AND DRAIN PIPES.ALL PIPES BELOW LAVATORIES
- - -- - ��� - 15 � 12 15 1 �� 3 - -L
- TILE TYPICAL FOR ALL WALLS BEHIND MIRROR. ENSURE
ll 21 _- � - - - - ---21 WILL BE INSULATED OR CONFIGURED TO PROTECT AGAINST THAT MIRROR COMPLETELY
CONTACT IN ACCORDANCE TO SECTION 606.5 FBCA SEE TILE PATTERN SCHEDULE
DETAIL 26/A8.1 CONCEALS FIELD TILE
D. DOOR:36"WIDE WITH PUSH/PULL HARDWARE AND SIGNAGE. N 8
1 -3 5'-7 5'-41/2" 1'-3" g a 12 3" 3"
E. URINAL: MAXIMUM CLEARANCE TO RIM OF URINAL IS 17"AS ------_----- 11
SPECIFIED ON SHEET AC1. 14
14 --2 ACRS / 4 - - -F. WATER CLOSET: RIM TOP AT 17"-19"A.F.F.AUTOMATIC FLUSH 13 1 O I DOOR / 13
CONTROL 1 `� 1 1 I M 4
6 1 3 PS 0 6 3 O I 3
G. TOILET PAPER DISPENSER:CENTERLINE OF TOILET PAPER 1I 4FRAME 15 to�
15 r
DISPENSER WILL BE 7"-9"FROM THE FRONT OF WATER CLOSET
2 y C-0
O I1:1 \ 7 Y m
H. PAPER TOWEL&OTHER DISPENSERS :48"MAX HT A.F.F.TO LINE -- - �-- 7A 1 \ 16 1 14 � 7
OF OPERATION. 9p�[ 11-1 , - \ I �, � I I W
4 _41 . 11�1 z. RE:SHEET AC1 FOR ACCESSIBILITY REQUIREMENTS PL 1 S-2 29 0 j
A8.2 � J
J. BARRIER-FREE: PROIVE 32"MIN.CLEAR OPENING AND SELF- S-2 PL-1 �
CLOSING DOORS FOR ACCESSIBLE STALLS. J U)
Q z
1 PUBLIC RESTROOM ACCESSORIES DIAGRAM A 6 MEN'S RESTROOM ELEV. 7 MEN'S RESTROOM ELEV. g MEN'S RESTROOM ELEV. g MEN'S RESTROOM ELEV. Q � Uj
A8.2 114"=1'-0" A8.2 114"=1'-0" A8.2 114"=1'-0" z � LU Q
N �
DASHED LINE INDICATES 1/2"DUROCK AT BASE
OF WALL TO 48"HEIGHT AND 1/2"PLYWOOD
ABOVE DUROCK BEHIND WALL MTD SHELVES.
. .. ... .. ..
METRO WIRE AP AND PAPER SO \ / ,..
_ A FRPC...HORN STROBE _ _ 0
. . . . . .. .
FRP : : FRP
\ / D2 FRPC
SHELVING SYSTEM ... T WEL. ... ... ::: . . .. ... . .. .. ... ... . . .. .. . . .. . . ... . . .. ... . . .. ... ... . . ... ... . ... .. ... ... . . ... . .......... . .. . . . _ . . ._ .. ._.
0 � O
N
FRPC1.TYP. FRPC FRPC
FRP RE.Al2/A9.0 FOR FRPC
- - - -
C
D111.. . .. . . . .. .
-d
ISL2 .-... ... . :.::... .. .. ... ... ... ... ... ... ... ... ._ ... ... ... . . ... . . . ... .. ... ... ... ... ... ... ... ... ..::. _. ... c�
D11 _ _. . . _ .. _ _ .. . . . . . . ._ .. _. _ ..
MOUNTING HEIGHT S
D2 D11
A FRPC ..... . . . . .. . .
/ . . ... . . . _ ... -. ... ... ... . . . ... ... .. ... ... ... ... . . . ... ... ... ... ._ _ ... ... ... . . .. . . .
FRPC FRPC _ _. ... . . . _ . . . . . . . . .
\ /
D2
01.\ / FRPC .. . . . .. . ... . . . .. _. _. ... .. 0\ 1.1. 1. .N
/
_ . . . /
o _
O
� -
A _
. . . _ . . . . . . _. ... ... . _ .. . . . _. .
i� _ . ... .. . . . . . . . . . .. ... .. ... . . . . . . ... . . . . .. ........ . ..... . . . .. ..... .. .. . . ._.
. . . .. . . . . . _ _. . . . . . .. . ... .. ... ... _. _ . ... .. _. . . _ .. . _. ... . . . . .. ..
.1.
\ / .. .. . . . . . . .. .. . . . . .. . . .. . . . . . .. ... . . .. . . . . . ... ... .. ... . . . . . . ... . . . . .. ... . ..... . ._ . .... ..... .. .. . . ._.
v \ /
. . . .. . . . _ . .. . . . . . . . .. ... .. ... ... . . _ ... .. ... . . . . .. .. ... _ .. ... ... . . ... ... .. . ... . . ... .. . ... .. J_. ... ... ... ... ... ... ... .. ... ... ... . ... ... ... ... ... ... ... ... ... .. ... ... ... ... ... ... .. ... ... ... ... .. ... ... ......... ..............I...1...1.1.I. -..............I. I.1.1.I .... c
� OPEN TO FOOD
a .. . . . . . . _ _. . _. . . . . . _._.. . . . _.... . ... . . ._ . _...._...... .. . . . . .
. . . _. . . _ _ .. . _. _ _ . . .. _. . . _ _ . . . . . . . _
SERVICE \ / 1.1. 1. 3
ii _ .. ._ . . . . . . . .. . . . _. . . . . . . . . . . . _. . . . . _ . . . . . . . . . _ . _...... .. _ _ . . 3
----- -- - PEN _ . . . . . . . _ .. . .. . . . . . . _. ._ 1._. . . . _ . . . . . . . ._ _ . _...... .. _ _ . ..
0 z
H . . . . _. . . . .1. . .. . . ... . . _. . . . .. ... ... : _ _. . ... . . . . . . . .. _ . . . . . . . . _
1.
1.
1.
0o PEN TO F D
ACRS
0 00
\ 1-1-1-1-1-1-1-1-
F1.5 1. D2
I - - - . .. . . . . . ... . ... . . . . . ... .. . . .. _ ..
01. 1.
_ SERVICE _ .. ... ... . 1.
I
_ . _ _ . ..
ch \ F �j I- - - - - I I - - - - - - - - - / \ - - I � � , � .. ..- ___ - .' '.. . . ._ .. ... ... .. ... . . . . ... ... _. _ ... ... ... . . ... _. . ... ... .. .. ... .. ... ... _ . . ... .. ... .. ._ ..
%
e
1.
. 11-L.-, -
1.
I.
Y - I - - - - � � \ _. ... _. ... . . . ... ... ... ... _. ... ... . ... ._ _. ... ... ... ... .. ... ... . .._..... . . ....................... . ........................... ....
_. - .. ... .. .. ... .. .. ... - ..
o �
..1 .1. 1.I _. . ... ... _. ... ... ... ... .. ... ... I.. ... ... .I. .. ., _. ... ... ... ... .. ... _. ... ..
I 11-1-1-1-1-1-1-1-1-1
... ... ... ... _. . .. ... .I. .I. .I ... ... _. I.. ... .I. .1. .. ... ... ... ... ... ... .. ... _. I.. ... .I. .I. . ... ., ..I . ... ... . . 1... ... . ... ._ _. ... ..
I.
O / \
/ \
_ . ... .. . . . . . . _ _ .. . . . . . .. .. _ .. . . . . . ._ _ ... . . . . . . ... . . . .. ......... . ..... . . . . . .... ...... .. . . . . .
. . . . . . . . / \ _ _. . . . . . . w
/ \ . . . . . . _ .. ... . . . . . .. ... ... . . _ .. . . . _ _ _
0
o . 1- .. . _ .. ... . . . . _ .. . . . ._ .. _ .. ... ... . . ... ... .. . . . ._ _
FRAME
7 ��� ���I - ; - - � / - I � I - I 1� ��� - - I � - - - - � I - - � - - - - - I I - - \
_ _ . . / \ _ _ _ _ ..................... .
- _ _. . _. .. _ _ t
1 .
n
d O
RB3 2x12 BLOCKING RB3 I
RB3 RB3 F5 RB3 RB3 F5 RB3 RB3 RB3 RB3
BETWEEN STUDS RB1 RB3 B19 B19 B21
B21 ` co
U-)
m
4t
10 WASHROOM ELEV. 11 WASHROOM ELEV. 12 WASHROOM ELEV. 13 BACKROOM ELEV. 14 BACKROOM ELEV. 15 BACKROOM ELEV. 16 BACKROOM ELEV. i �W//
A8.2 114"=1'-0" A8.2 / 1/4"=1'-0" A8.2 1/4"=1'-0" A8.2 1/4"=1'-0" A8.2 1/4"=1'-0" A8.2 1/4"=1'-01, A8.2 1/4"=1'-0" - LL
0
16
MOUNT BUG LIGHT DIRECTLY DUPLEX SURGE TANK ON FRP- - CSR UNIT A U
OVER RECPT. SO POWER RECPT. WRAPPED SHELF RE: PLUMBING SODA CHASE SODA CHASE z
AIR CURTAIN RE: DETAIL 8/A9.0 RE:9/A2.0 : / .0 AIR CURTAIN o � 0
CORD IS CONCEALED DUPLEX RE: MECH
AIR CURTAIN RE: MECH
RE: ELECTRICAL -
RE:MECH. RECPT. FRPC SURGE TANK ON . z
. O FRP-WRAPPED SHELF _ � N
S
FRPC . Q
RE. DETAIL 8/A9.0 . . . . . . . . . . . . . .... -
.... :. ..: . 2
.: FRPC FRPC . . . . . . . . . ..
WATER � - - - - � - - - - - - - - 1. - - I ... ... ...I - - - - - - - I - - - - - I-/ - - - - - - - - � - - - - - - - - - - - - - - - 1� ��, - - __,,__%�HEATER FRPC FRPC ISL2 �I - - F w
DISCONNECT \ CO2 ALARM AND AIR CURTAIN $ m J
WARNING SIGN BY _ _ _ . FRPC _
QUAD. RECPT. z
TRASH \ . . :::.. . . . . � -
FRPC . . . . w
FRP CO2SYSEM VENDOR
MOP RACK ... . BA C \ _ ... P6
G / O _ \ O L0
ALARM \ OCCUPANCY 06 �/
:.--... -- oo--.:.
HOLDERS . . . . _ _ . . . . ... DR&FIRM J
STROBE oo.: .. ._ \ DATA RECPT. . . . . . _ __ OD LL
00o P6 ACRC SENSOR _ a LL
DR&FIRM DOOR = = _
0
DUPLEX: / o .... o \ a W
OPEN E BNB SHELF _ . . . .. __ Q
_ ALARM PULL 0 Q U nn//
- RECPT. A 00 _ W L.1_
/ P6 - STATION LU
�, FA PULL :: / P6 - v O W
- \ STATION
C .. - - - - - - - - - - - - - - - - - I - - - I I / DR&FIRM FRAME \ FIRE - - o Q z - J w. ...
/ EXSTINGUISHER : :' / Q . W
/ . . z -
MOP SINK o \ / \ D2 / - ~
RB3 _ \ / RB3 / \ CO2 ALARM AND 1.1. F z
w 0 LL w
F__ . . 11 L I , ,
"' WARNING SIGN / d p w
BY CO2 SYSEM � CL `�'
WATER HEATER ON 30"x30"x4"H A RB3 OCC. WATER HEATER ON 30"x30"x4"H RB3 VENDOR D1 D2 0
PRE FAB CONCRETE PAD RB3 SENSOR PRE FAB CONCRETE PAD RB1 RB3 RB3
b
A �pF F.
0- G Digitally signed by R Day
Lp13 _�t7vM-��R�°p00000;6 �.
--- ---- O=CUHACI AND PETE IJ� -II-II C
17 STAGING ELEV.
18 STAGING ELEV. 19 STAGING ELEV. 20 STAGING ELEV. 21 DELIVERY VESTIBULE 22 DELIVERY VESTIBULE 23 DELIVERY VESTIBULE 24 DELIVERY VESTIBULE ENGWEERSd,,,,,E S
d � Reason This document �r�
aa electrogqically signed 4n aJe,Qt�o art
A8.2 114"=1'-0" A8.2 114"=1'-0" A8.2 _ A8.2 114"=1'-0" A8.2 114"=1'0" A8.2 114"=1'-0" A8.2 114"=1'-0" A8.2 114"=1'-0" R"y Day usfi9 a Digital S g 1!�rifitd pi
1/4 1-0 of this comment re �der�ksi e
t C and sealed a.d the s' re& ri d
U
on any ele�ot�Qnic co p
Date:2021.1tl.26 15: :09-CWO'
a
m
m
n
RESTROOM ACCESSORIES SCHEDULE f 07121/2021
z
# ITEM MANUFACTURER MODEL# REMARKS SUPPLIED BY N
1/2"M.R. GWB iu o 0 0 0 0
2 2 N N N N N
I 1 ELECTRONIC HAND DRYER EXCEL DRYER INC. XLERATOR XL-C CHROME ELECTRONIC HAND DRYER WITH RECESSED KIT HJC m ti M (M ao
•,'_ I SCHLUTER JOLLY 2 T.P.HOLDER - - 7"MIN-9"MAX IN FRONT OF WC.OUTLET 19"A.F.F. HJC 2 qt N N o N
ANODIZED ALUMINUM
P6 I FOR 3/8"TILE 3 SOAP DISPENSER TORK 571608 BLACK TOUCHLESS ELECTRONIC SOAP DISPENSER-BATTERY OPERATED HJC � a) o 0 0 0 0
oIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII FIELD TILE PER
4 MIRROR BRADLEY 780-2436 24"X 36"MIRROR WITH S.S. FRAME IN SATIN FINISH. HJC -2 0
a ELEVATIONS
RECESSED HAND DRYER 5 COAT HOOK BOBRICK B-233 STAINLESS STEEL WITH SATIN FINISH MOUNT HJC o =
0 = WALL TILE,CT3 6 42"GRAB BAR BRADLEY 8120-00142 STAINLESS STEEL WITH SATIN FINISH,BOTH RAILS 42"IN LENGTH HJC V) o p
v } PROVIDE DUROCK UP TO o A& � M I � COUNTERTOP .11 7 LAV CABINET CABINET - CABINET BELOW LAVATORY SUPPLIED AND INSTALLED BY CABINET VENDOR.COORDINATED CABINET 16 o 0
0 4'-0"ALL WALLS OF TO BE ONE SEALANT A BY GC. fn •0 L o w LU
W G RESTROOMS N I 2 6 XPIECE Ill-8a 7A LAV SHIELD TRUEBRO 2018-AS L FOR AMERICAN STANDARD LUCERNE LAVATORY HJC °�' N p
r% I S T L R: W a i o - I. -
"' M ACCENT TILE PER PROVIDE CORIAN 8"MIN. D E FOR 8 TOILET PARTITION SCRANTON SHALE SOLID PLASTIC PARTITIONS(NO SITE LINES)W/S.S.PRIVACY SLATS,AND SELF-CLOSING HJC t g N m
n- 3/8"TILE q DOORS.PROVIDE PULLS ON BOTH SIDES OF ADA STALL DOOR. � w w w
CARBON DIOXIDE GAS --- ------------- ----- I ELEVATIONS FINISHED END
_ ''� I AND 1/2"THICK CORIAN PANEL 9 NAPKIN DISPOSAL UNIT BRADLEY 4722-15 STAINLESS STEEL WITH SATIN FINISH.WOMEN'S ROOM ONLY. HJC 116 - a 00 a-
,0-1, VENTILATE THIS AREA TILE FINISH BACKSPLASH AT TO MATCH VANITY GLUED 10 WALL BRACKET BRADLEY - MOUNT ON TOP RAIL WHERE PARTITIONS MEET WALL HJC t z
= BEFORE ENTERING. - WALLS TO DUROCK 12 ECONOMIZER DISPENSER MICROBURST 9000 401375 2 UNITS PER RESTROOM, 1 NEAR DOOR AND 1 OPPOSITE.TOP 2"MIN FROM CEILING WAWA Q
o M SCHLUTER JOLLY N
A hi carbon dioxide as(CO,) A 13 TOILET SEAT COVER DISP. - - ONE PER STALL HJC
high g o 0 "v I ANODIZED ALUMINUM OFFSET TAILPIECE C U 0 LY
concentration in this area can FOR 3/8"TILE RE:PLUMBING 0 Z I OR 14 18"GRAB BAR BRADLEY 8120-00118 STAINLESS STEEL FINISH.MOUNT RAIL VERTICALLY. HJC -3°
'v = 1'TO 1-1/2" r
cause suffocation. o N 3/8"TILE 15 WASTE RECEPT. BOBRICK B-3644 RECESSED INTO WALL-4"WALL RECESS REQUIRED,4"PROTRUDING BIN HJC a
PARTITION - COUNTERTOP Lo
= a $ a
V LEG AND CABINET BY
1/4"DUROCK CEMENT BRD 16 SOLID SURFACE PANEL DUPONT CORIAN COLOR:COTTAGE LANE 1/2 THICK, 14-3/4 WIDE X 20 HIGH PANEL MOUNTED 6 A.F.F.,LOCATED BELOW HAND CABINET m o o In
WIDTH 8" _ 6"MIN. , DRYER.SEE DETAIL 311A8.1. °'
........................................................ .................................................................................. I N
6 6 .......................................: - _ o
oa Z o
CABINETRY MFR. 1/2 DUROCK CEMENT BRD „ `" w
............................................. :.::,................................................. - 1/4 DUROCK CEMENT o 0
I BOARD
�' I 17 DOOR STOP(PARTITION) SCRANTON - SUPPLIED BY TOILET PARTITION MANUFACTURER.LOCATE AT BOTTOM OUTSIDE CORNERS HJC = w Z Y
EPDXY FLOORING W/ OF DOOR. 0 0 o " � o ¢ w N
EF 1 1/2"DUROCK CEMENT - REMOVEABLE INTEGRAL COVE "' a o c =
NOTES: 1. SIGNAGE SHALL COMPLY WITH I PANELS 21 FUTURE ACCESSORY HJC izz
NFPA-55 CHAPTER 13 27 I BOARD m BASE
REQUIREMENTS. GT1 A8 2 EPDXY FLOORING W/ PLAN @ TILE SECTION(@ EPDXY BASE
2. SIGNAGE TO BE FURNISHED AND INTEGRAL COVE
A1.
INSTALLED BY CO2 SYSTEM VENDOR. BASE ELEVATION SECTION 8 .25 CO2 WARNING SIGNAGE 26 RESTROOM TILE PATTERN LAYOUT 27 RESTROOM COVE BASE 29 RESTROOM SINK DETAIL 31 CORIAN PANEL DETAIL NOTE:ALL RESTROOM ACCESSORIES INSTALLED BY GENERAL CONTRACTOR UNLESS NOTED OTHERWISE.
A8.2 N.T.S. A8.2 3/8"=1'-0" A8.2 3"=1'-0" A8.2 3/4"=1'-0" A8.2 3"=1'-0" 2. REFERENCE SHEET EQ1 FOR SPECIFIC EQUIPMENT IDENTIFIED HERE-IN.