Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional 'Regulation - Residential Performance'Method Project Name: Foley Residence Builder Name: Street: 17703 Bridle Way Permit Office: St. Lucie County City, State. Zip: Port St. Lucie, FL, 34.987 Permit Number QZQ(j Owner. Foley Residence Jurisdiction: St.•Lucie County Design Location: FL, Fort Pierce Courtly: St. Lucie (Florida Climate Zone 2 ) 1• New construction or existing New (From Plans) 10. Wall Typep2574.0 sg(t,) Insulation Area 2. Single family or multiple family Detached Concrete Block -Iini tnsul, Exterior b. Frame - Wood, Adjacent b. R=4.1 2340.00 ft? R=11.0 234.00 ft2 3. Number of units, if multiple family 1 c. NIA , R= ft2 4. Number of Bedrooms 4 d.N3A R= ftz 11. Ceiling Types (2595:0 sgfL) insulation Area 5. Is this a worst case? No a -Roof Deck (UnVented) R--20.0 2595A0 ftz 6. Conditioned floor area above grade (ftl 2595 b, N/A R= ftz Conditioned floor area below grade fft') Or c. NIA R= ftz 7. Windows(295.8 sgft.) Description Area 12• Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ft2 6 90 a. U-Factor. Sgi. U=0.65 295.83 ftz SHGC: SHGC=0.25 b. U-Factor: N/A ftz 11'Cooling systems kelWhr Efficiency SHGC: a.'Central Unit 41.5 SEER:16.00 c. U-Factor N/A f22 SHGC: Area Weighted Average Overhang Depth: 5.624 ft. .14. Heating systems kBtu/hr Efficiency Area Weighted Average SHGC: 0.250 a..Electric Strip Heat 34.0 COP:1.00 8. , Skylights Area c. U-Factor.(AVG) NIA ft2, 15. Hat water systems SHGC(AVG); NIA a, Electric Cap: 50 gallons 9. Floor Types (2595.0 sgft.) Insulation Area EF: 0.950 a. Slab -On -Grade Edge insulation R=0.0 2595.,00 ft2 b. Conservation features b. NIA R= ft2 None c. NiA R= ft? 16. Credits CF,'Pstat Glass/Floor Area: 0.114 Total Propbsed;llhaififled Loads: 75.41.� Total Baseline Loads: 78.78.4, I hereby certify that the plans and specifications covered'by Reviews of the plans and this calculation are in compliance'vrith the Florida Energy Code. specifications covered by this calculation indicates compliance3f " t(� �•., _ '' r ��7 with the' Florida Energy Code. O PREP D _ Before construction is completed i z r r 1" DATE: this building uAll be inspected for compliance -%ith Secti6n'553.808 n, - - I hereby certify th is°b ing a designed, is in compliance , Florida Statutes. 1 �00 with the F►orid�- erg a W�T� OlNNER/A ENT: - BUILDING OFFICIAL_: DATE: — DATE: - Compliance requires certification by the air handler unit manufacturer.thatthe air handier enclosure qualifies as certified factory -sealed in arcgL&ncq with R403.3.2.1. -Compliance requires an it a and Insulation i s ection Checklist•in accordance Wilb R402.4.1.1 and this project requires an envelope leakage test report with envelope IeaEcage , gm, e t " 3t• Ka (R442A.1:2). . - Compliance with a proposed On,requires tic eakage test Report confirming duct leakage to outdoors,. tested in accordance with ANSi1RESNET11CC 380, is _._ • t• z�ra�� n for whole house. 617/2021 11:05 AM 7,0,00 - FtaRes2020 FBC 7th Edition (2b20) 'Compliant Soft ;are 'Page 1 of 7 L P_)PN V A FORM R405-2020 INPUT SUMMARY GHF-GKL15T KEPOKT PROJECT Title: Foley Residence Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2595 Lot # Owner Name: Foley Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 17703 Bridle Way Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Port St. Lucie , Family Type: Detached FL, 34987 New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2595 23355 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Bedroom 4 221 1989 No 1 1 1 Yes Yes Yes 2 BAth 3 78 702 No 0 1 Yes Yes Yes 3 Bedroom 3 172 1548 No 2 1 1 Yes Yes Yes 4 Closet 3 24 216 No 0 1 No Yes Yes 5 Hall 32 288 No 0 1 Yes Yes Yes 6 Bath 2 49 441 No 0 1 Yes Yes Yes 7 Toilet 2 42 378 No 0 1 No Yes Yes 8 Bedroom 2 158 1422 No 1 1 1 Yes Yes Yes 9 Hall 52 468 No 0 1 Yes Yes Yes 10 Office 130 1170 No 2 1 Yes Yes Yes 11 Family Room 400 3600 No 2 1 Yes Yes Yes 12 Kitchen 260 2340 Yes 2 1 Yes Yes Yes 13 Dining 130 1170 No 2 1 Yes Yes Yes 14 Foyer 70 630 No 0 1 Yes Yes Yes 15 Bath 40 360 No 0 1 Yes Yes Yes 16 Laundry 90 810 No 0 1 Yes Yes Yes 17 Pantry 24 216 No 0 1 No Yes Yes 18 Hall 97 873 No 0 1 No Yes Yes 19 M WIC 84 756 No 0 1 No Yes Yes 20 M Bath 141 1269 No 0 1 Yes Yes Yes 21 Toilet 24 216 No 0 1 Yes Yes Yes 22 Master Bedroom 264 2376 No 2 1 1 Yes Yes Yes 6/7/2021 11:05 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 2 of 7 FORM 14405-2020 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 23 Closet 2 13 117 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Bedroom 4 40 ft 221 ft2 ---- 1 0 0 2 Slab -On -Grade Edge Insulatio BAth 3 6 ft 78 ft2 ---- 1 0 0 3 Slab -On -Grade Edge Insulatio Bedroom 3 12 ft 172 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio Closet 3 1 ft 24 ft2 ---- 1 0 0 5 Slab -On -Grade Edge Insulatio Hall 3 4 ft 32 ft2 ___- 1 0 0 6 Slab -On -Grade Edge Insulatio Bath 2 4 ft 49 ft2 ---- 1 0 0 7 Slab -On -Grade Edge Insulatio Toilet 2 1 ft 42 ft2 ---- 1 0 0 8 Slab -On -Grade Edge Insulatio Bedroom 2 31 ft 158 ft2 ---- 1 0 0 9Slab-On-Grade Edge Insulatio Hall 2 6 ft 52 ft2 ---- 1 0 0 10SIab-On-Grade Edge Insulatio Office 18 ft 130 ft2 ---- 1 0 0 11Slab-On-Grade Edge Insulatio Family Room 20 ft 400 ft2 ---- 1 0 0 12SIab-On-Grade Edge Insulatio Kitchen 13 ft 260 ft2 ---- 1 0 0 13Slab-On-Grade Edge Insulatio Dining 23 ft 130 ft2 — 1 0 0 14SIab-On-Grade Edge Insulatio Foyer 7 ft 70 ft2 ---- 1 0 0 15SIab-On-Grade Edge Insulatio Bath 6 ft 40 ft2 _--- 1 0 0 16SIab-On-Grade Edge Insulatio Laundry loft 90 ft2 ---- 1 0 0 17SIab-On-Grade Edge Insulatio Pantry 1 ft 24 ft2 ---- 1 0 0 18SIab-On-Grade Edge Insulatio Hall 1 1 ft 97 ft2 ---- 1 0 0 19SIab-On-Grade Edge Insulatio M WIC 1 ft 84 ft2 ---- 1 0 0 20Slab-On-Grade Edge Insulatio M Bath 11 ft 141 ft2 ---- 1 0 0 21SIab-On-Grade Edge Insulatio Toilet 4 ft 24 ft2 ---- 1 0 0 22Slab-On-Grade Edge Insulatio Master Bedroom 39 ft 264 ft2 ---- 1 0 0 23Slab-On-Grade Edge Insulatio Closet 2 6ft 13 ft2 ---- 1 0 0 6/7/2021 11:05 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 7 ...w �..wwww w P'fV ALICA VI 101ir C200^011r FORM R405-202U iNrlu 1 Qu1V11VIMM I w I I.D-1 �•� ROOF Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2811 ft2 0 ft2 Medium N 0.6 No 0.9 No 20 22.62 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 2595 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) Bedroom 4 0 Blown 221 ft2 0.1 Wood 2 Under Attic (Unvented) BAth 3 0 Blown 78 ft2 0.1 Wood 3 Under Attic (Unvented) Bedroom 3 0 Blown 172 ft2 0.1 Wood 4 Under Attic (Unvented) Closet 3 0 Blown 24 ft2 0.1 Wood 5 Under Attic (Unvented) Hall 3 0 Blown 32 ft2 0.1 Wood 6 Under Attic (Unvented) Bath 2 0 Blown 49 ftZ 0.1 Wood 7 Under Attic (Unvented) Toilet 2 0 Blown 42 ft2 0.1 Wood 8 Under Attic (Unvented) Bedroom 2 0 Blown 158 ft2 0.1 Wood 9 Under Attic (Unvented) Hall 2 0 Blown 52 ft2 0.1 Wood 10 Under Attic (Unvented) Office 0 Blown 130 ft2 0.1 Wood 11 Under Attic (Unvented) Family Room 0 Blown 400 ft2 0.1 Wood 12 Under Attic (Unvented) Kitchen 0 Blown 260 ft2 0.1 Wood 13 Under Attic (Unvented) Dining 0 Blown 130 ft2 0.1 Wood 14 Under Attic (Unvented) Foyer 0 Blown 70 ft2 0.1 Wood 15 Under Attic (Unvented) Bath 0 Blown 40 ft2 0.1 Wood 16 Under Attic (Unvented) Laundry 0 Blown 90 ft2 0.1 Wood 17 Under Attic (Unvented) Pantry 0 Blown 24 ft2 0.1 Wood 18 Under Attic (Unvented) Hall 1 0 Blown 97 ft2 0.1 Wood 19 Under Attic (Unvented) M WIC 0 Blown 84 ft2 0.1 Wood 20 Under Attic (Unvented) M Bath 0 Blown 141 ft2 0.1 Wood 21 Under Attic (Unvented) Toilet 0 Blown 24 ft2 '0.1 Wood 22 Under Attic (Unvented) Master Bedroom 0 Blown 264 ft2 0.1 Wood 23 Under Attic (Unvented) Closet 2 0 Blown 13 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below ()rnt Space 10 Wall Typea _ 1 E Exterior Concrete Block - Int InsuBedroom 4 4.1 12 0 9 0 108.0 ft2 0 0 0.5 0 _ 2 S Exterior Concrete Block - Int InsuBedroom 4 4.1 16 0 9 0 144.0 ft2 0 0 0.5 0 _ 3 W Exterior Concrete Block - Int InsuBedroom 4 4.1 12 0 9 0 108.0 ft2 0 0 0.5 0 _ 4 E Exterior Concrete Block - Int Insul BAth 3 4.1 6 0 9 0 54.0 ft2 0 0 0.5 0 _ 5 E Exterior Concrete Block - Int InsuBedroom 3 4.1 12 0 9 0 108.0 ft2 0 0 0.5 0 6 W Exterior Concrete Block - Int Insul Hall 3 4.1 4 0 9 0 36.0 ft2 0 0 0.5 0 6/7/2021 11:05 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 7 FORM R405-2020 INPUT SUMMARY GIIEGKLIST KEPUKT WALLS Adjacent Cav ity Width Height Sheathing Framing Solar Below Space 'lie Et In Et In Area R-Vahle Prnction Absor C, 7 E Exterior Concrete Block - Int Insul Bath 2 4.1 4 0 9 0 36.0 ft2 0 0 0.5 0 8 N Exterior Concrete Block - Int InsuBedroom 2 4.1 13 0 9 0 117.0 ft2 0 0 0.5 0 9 E Exterior Concrete Block - Int InsuBedroom 2 4.1 11 0 9 0 99.0 ft2 0 0 0.5 0 10 W Exterior Concrete Block - Int InsuBedroom 2 4.1 7 0 9 0 63.0 ft2 0 0 0.5 0 11 N Exterior Concrete Block - Int Insul Hall 2 4.1 6 0 9 0 54.0 ft2 0 0 0.5 0 12 N Exterior Concrete Block - Int Insul Office 4.1 13 0 9 0 117.0 ft2 0 0 0.5 0 13 E Exterior Concrete Block - Int Insul Office 4.1 5 0 9 0 45.0 ft2 0 0 0.5 0 14 S Exterior Concrete Block - Int Insftmily Room 4.1 20 0 9 0 180.0 ft2 0 0 0.5 0 15 S Exterior Concrete Block - Int Insul Kitchen 4.1 13 0 9 0 117.0 ft2 0 0 0.5 0 16 N Exterior Concrete Block - Int Insul Dining 4.1 13 0 9 0 117.0 ft2 0 0 0.5 0 17 W Exterior Concrete Block - Int Insul Dining 4.1 10 0 9 0 90.0 ft2 0 .0 0.5 0 _ 18 N Exterior Concrete Block - Int Insul Foyer 4.1 7 0 9 0 63.0 ft2 0 0 0.5 0 19 E Exterior Concrete Block - Int Insul Bath 4.1 6 0 9 0 54.0 ft2 0 0 0.5 0 _20 N Exterior Concrete Block - Int Insul Laundry 4.1 10 0 9 0 90.0 ft2 0 0 0.5 0 21 W Exterior Concrete Block - Int Insul M Bath 4.1 11 0 9 0 99.0 ft2 0 0 0.5 0 22 W Exterior Concrete Block - Int Insul Toilet 4.1 4 0 9 0 36.0 ft2 0 0 0.5 0 23 N Exterior Concrete Block - Int InsMaster Bedro 4.1 16 0 9 0 144.0 ft2 0 0 0.5 0 24 E Exterior Concrete Block - Int InsMaster Bedro 4.1 6 0 9 0 54.0 ft2 0 0 0.5 0 25 W Exterior Concrete Block - Int InsMaster Bedro 4.1 17 0 9 0 153.0 ft2 0 0 0.5 0 26 E Exterior Concrete Block - Int Insul Closet 2 4.1 3 0 9 0 27.0 ft2 0 0 0.5 0 27 S Exterior Concrete Block - Int Insul Closet 2 4.1 3 0 9 0 27.0 ft2 0 0 0.5 0 _28 S Garage Frame - Wood Bath 11 4 9 36.0 ft2 0.23 0.5 0 29 S Garage Frame - Wood Hall 1 11 5 9 45.0 ft2 0.23 0.5 0 30 S Garage Frame - Wood M WIC 11 6 9 54.0 ft2 0.23 0.5 0 _ 31 S Garage Frame - Wood M Bath 11 5 9 45.0 ft2 0.23 0.5 0 _ 32 S Garage Frame - Wood Toilet 11 6 9 54.0 ft2 0.23 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated Foyer None .39 6 8 48 ft2 2 E Insulated Bath None .39 2 10 6 10 19.4 ft2 3 S Insulated Hall 1 None .39 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S 2 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 1 ft 7 in 1 ft 4 in None None 2 E 4 Metal Low-E Single Yes 0.65 0.25 Y 5.3 11:2 1 ft 7 in. 1 ft 4 in None None 3 E 5 Metal Low-E Single Yes 0.65 0.25 Y 15.0 ft2 1 It 7 in 1 ft 4 in None None 4 W 10 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 1 ft 7 in 1 ft 4 in None None 5 N 11 Metal Low-E Single Yes 0.65 0.25 Y 8.0 ft2 1 ft 7 in 1 ft 4 in None None 6 N 12 Metal Low-E Single Yes 0.65 0.25 Y 30.0 ft2 6 ft 0 in 1 ft 4 In None None 6/7/2021 11:05 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 5 of 7 FORM k05-2020 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown is the entered, Proposed orientation. / V # Wall Ornt ID Frame Panes NFRC Overhang U-Factor SHGC Imp Area Depth Separation Int Shade Screening 7 8 9 10 11 12 13 14 S 14 Metal S 14 Metal S 15 Metal N 16 Metal N 20 Metal W 21 Metal N 23 Metal W 25 Metal Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Low-E Single Yes Yes Yes Yes Yes Yes Yes Yes 0.65 0.25 Y 20.5 ft2 13 ft 0 in 0.65 0.25 Y 45.0 ft2 13 ft 0 in 0.65 0.25 Y 16.0 ft2 13 ft 0 in 0.65 0.25 Y 30.0 ftz 6 ft 0 in 0.65 0.25 Y 8.0 ft2 1 ft 7 in 0.65 0.25 Y 12.0 ftz 1 ft 7 in 0.65 0.25 Y 30.0 ftZ 1 ft 7 in 0.65 0.25 Y 16.0 ft2 1 ft 7 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in 1 ft 4 in None None None None None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1254 ftZ 1254 ft2 26 ft 9 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000343 2335.5 128.13 240.55 .1135 6 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 41.5 kBtu/hr cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Model # Collector Area Storage Volume FEF None None ft' 6/7/2021 11:05 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 7 FORM R405-2020 IKIPI IT SI IMIIIIAPV nUCt%1r1 ier oonnnr DUCTS / --- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 90 ft2 Attic 20 ft2 Prop. Leak Free Attic -- cfm 77.8 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Venting Jan Feb Feb Mar ki Mar �(� Apr Apr M:y May n Jurj n rj Jul Jul rjAug ug �Xj Sep Oct �X� Nov Dec Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM PM 78 80 78 80 78 78 78 78 78 78 78 78 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 .78 78 78 78 78 78 78 78 Heating (WD) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM PM 66 68 66 68 66 68 66 66 68 68 68 68 68 68 68 .68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 Oft 0.3 Bedroom 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BAth 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Closet 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Bedroom 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 2 Default(8 Ibs/sq.ft. ft2 ft 0.3 Office Default(8 Ibs/sq.ft. ft2 ft 0.3 Family Room Default(8 Ibs/sq.ft. ft2 ft 0.3 Kitchen Default(8 Ibs/sq.ft. ft2 ft 0.3 Dining Default(8 Ibs/sq.ft. ft2 ft 0.3 Foyer Default(8 Ibs/sq.ft. ft2 ft 0.3 Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Laundry Default(8 Ibs/sq.ft. ft2 ft 0.3 Pantry Default(8 Ibs/sq.ft. ft2 ft 0.3 Hall 1 Default(8 Ibs/sq.ft. ft2 ft 0.3 M WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 M Bath Default(8 Ibs/sq.ft. ft2 ft 0.3 Toilet Default(8 Ibs/sq.ft. ft2 ft 0.3 Master Bedroom Default(8 Ibs/s .ft. , ft2 ft 0.3 Closet 2 6/7/2021 11:05 AM 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 7 of 7 . FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U-Factor: Sgl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth Area Weighted Average SHGC: 8. Skylights Description a. U-Factor(AVG): N/A SHGC(AVG): N/A 17703 Bridle Way, Port St. Lucie, FL, 34987 New (From Plans) 10. Wall Type and Insulation Insulation Area Detached a. Concrete Block - Int Insul, Exterior R=4.1 2340.00 ft2 b. Frame - Wood, Adjacent R=11.0 234.00 ft2 1 c. N/A R= ft2 4 d. N/A R= ft2 11. Ceiling Type and insulation level Insulation Area No a. Roof Deck (Unvented) R=20.0 2595.00 ft2 2595 b. N/A R= ft2 Area c. N/A R= ft2 295.83 ft2 12. Ducts, location & insulation level R ft2 a. Sup: Attic, Ret: Attic, AH: Attic 6 90 ft2 13. Cooling systems kBtu/hr Efficiency ft2 a. Central Unit 41.5 SEER:16.00 ft2 5.624 ft. 0.250 Area ft2 9. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 2595.00 ft2 b. N/A R= ft2 c. N/A R= ft2 14. Heating systems a. Electric Strip Heat 15. Hot water systems a. Electric b. Conservation features None Credits (Performance method) I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy ving features which will be installed (or exceeded) in this home before final in c I n rwise, anew EPL Display Card will be completed based on installed Co comp ' t f res. Builder Signature: Date: 1(j I9 Address of New Home: 1 -77 03 (?)R:k I, c �p,,- City/FL Zip: -M G kBtu/hr Efficiency 34.0 COP:1.00 Cap: 50 gallons EF: 0.95 CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/7/2021 11:07 AM 7.0.00 - FlaRes2020 FBC 7th Edition (2020) Compliant Software Page 1 of 1 2020 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Foley Residence Builder Name: Street: 17703 Bridle Way Permit Office: St. Lucie County City, State, Zip: Port St. Lucie , FL , 34987 Permit Number: Y U Owner: Foley Residence Jurisdiction; St. Lucie County w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the finished surface. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC supply and return register boots that penetrate building thermal envelope shall be sealed to the sub -floor, wall covering or Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. T Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceelings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 6/7/2021 11:07 AM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1