HomeMy WebLinkAboutPRODUCT APPROVAL SHUTTERS ACCORDIONBusiness & Professional Regulation
BCIS Home � Log In User Registration I Hot Thplcs Submit Surcharge Stats & Facts Publications contact Us BCIS Site Map , Links 1, Search Ik
bu
Product ApprovaI
- USER: Public User
I . 1. 1 . i P
Product Approval Menu > Product or ARplicatlon Search > spllcation Lost > Application Detail
WHOM.r� FL # FL1850-R13
GO �OOAIApplication Type Revision
Code Version 2020
Application Status Approved
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@easternmeta Isom
Authorized Signature Bill Feeley
lrodricjuez@easternmetal.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Small
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Walter A. Tillit, Jr., P.E.
Evaluation Report
Florida License PE-44167
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2021
Validated By John Henry Kampmann Jr.
Validation Checklist - Hardcopy Received
Certificate of Independence FL18SO R13 COI M.V. ACCORDION CERTIFICATE OF INDEPENDENCE.pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM E1886
2012
ASTM E1996
2012
ASTM E330
2002
TAS 201, 202, 203
1994
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/28/2020
Date Validated 11/06/2020
Date Pending FBC Approvai 11/06/2020
Date Approved 12/15/2020
Summary of Products
FL #
Model,
Description
Number or
Name
1850.1
Bertha HV
Extruded aluminum blades folded together thru knuckles and retained by tracks to provide hurricane
Accordion -
protection.
Blade 3
(HVHZ)
Drawing#
17-103
Limits of Use
Installation Instructions
Approved for use
FL1850 R13 I] H V ACCORDION SHUTTER SYSTEM BLADE 3 INSTALLATION INSTRUCTIONS HVHZ df
in HVHZ: Yes
Verified By: American Test Lab of South Florida, Inc.
Approved for use
Created by Independent Third Party: Yes
outside HVHZ: Yes
Evaluation Reports
Impact
FL1850 R13 AE H.V, ACCORDION SHUTTER SYSTEM BLADE 3 EVALUATION REPORT,pdf
Resistant: Yes
Created by Independent Third Party: Yes
Design
Pressure: N/A
Other: Large Missile
Level "D". Max span
is 12'-7" for 35 psf
positive ASD load and
13'-0" for 35 psf
negative ASD load for
one specific condition
shown in span tables.
See additional loads
and spans on
engineered drawings.
1850.2
Bertha HV
Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection
Accordion
Shutter
(Combo) -
HVHZ -
Drawing#17-
102
Limits of use
Installation Instructions
Approved for use
FL1850 R13 I] H.V. ACCORDION SHUTTER SYSTEM BLADE 1 2 INSTALLATION INSTRUCTIONS HVHZ.pdf
in HVHZ: Yes
Verified By: American Test Lab of South Florida, Inc.
Approved for use
Created by Independent Third Party: Yes
outside HVHZ: Yes
Evaluation Reports
Impact
FL1850 R13 AE N.V. ACCORDION SHUTTER SYSTEM BIADEI 2 EVALUATION REPORT,pdf
Resistant: Yes
Created by Independent Third Party: Yes
Design
Pressure: N/A
Other: Large Missile
Level "D". Max. span
is 13'-2" for 30 psf
positive ASD load w/o
window blade, 16'-0"
for 30 psf negative
ASD load for HV1
blade w/o window
blade for conditions
indicated on schedule
#1, sheet 12. And
12'-3" for 30 psf
I positive ASD load w/o
window blade and
IT-5 for 30 psf
1 negative ASD load for
HV2 blade w/o
window blade. See
sheets number 12,
25, 28 and 28A of
installation drawings
for other spans and
pressures.
1850.3
Bertha HV
Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection
Accordion
Shutter -
Blade I Only
(HVH7) -
Drwg# 17-
122
Limits of Use
Installation Instructions
Approved for use
FL1850 R13 II H.V. ACCORDION SHUTTER SYSTEM BLADE 1 INSTALLATION INSTRUCTIONS HVHZ.pd
in HVHZ: Yes
Verified By; American Test Lab of South Florida, Inc.
Approved for use
Created by Independent Third Party: Yes
outside HVHZ: Yes
Evaluation Reports
Impact
FL1850 R13_ AE_ H.V. ACCORDION _SHUTTER SYSTEM BLADE 1 EVALUATION REPORT.p f
Resistant: Yes
Created by Independent Third Party: Yes
Design
Pressure: N/A
Other. Large missile
level ^D". Max, span
is 16'-U" and 14'-9"
for 30 psf ASD
negative load
depending on
centermates and
locking rod
configuration for the
HVi blade, V-0" for
+64, -72 psf load for
HV blade for
Keystone mountings
7'-0" for +75, -75 psf
for metals stud
mountings and 8'-0"
for 110 psf. for HV1
and HV1A working in
unison. See sheets 7,
11, 20 and 19
respectively of
installation drawings
for other spans and
pressures.
l 19i Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phopet 850-487-1824
The State of Florida is an ANEW employer. QRpyriq t 2007-2013 Stat of Florida., :: Privacy. Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to
this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487,1395. *Pursuant to Section 455.275(1), Florida
Statutes, effective October 1, 2012, pcensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may
be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department
with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S„ please click here .
Product Approval Accepts:
ILLMI W
Credit Card
Safe