HomeMy WebLinkAboutFL3607-M1-1-Modelri PCmm C 0 BOTTOM OF TRUSS 2" 1. YORK ROOF TOP UNITS ALONG WITH ANY ACCESSORIES WILL BE CHORD FURNISHED TO THE JOB SITE ON A SCHEDULED DELIVERY BASIS. 1-1/4" THE CURBS WILL COME SEPARATELY FROM A THIRD PARTY YORK WATER METER-c\MIN. SCOPE OF WORK- PENETRATION VENDOR. ALL ITEMS MUST BE REQUESTED WITH A NEEDED X 1fGAGE RAP (1) #10 X 2 SHEET METAL DELIVERY DATE IN THE AFI SCHEDULE REQUEST FORM AND SENT 1. REMOVE (4) EXISTING RTUs, CURBS, DUCT HANGERS AT 8'-0" SCREWS @ EACH TRUSS CHORD TO THE VENDOR AS SOON AS THE JOB NTP'S. SPACING. (NP•) 2. ONCE CONSTRUCTION HAS COMMENCED IT WILL BE THE RUNOUTS, AND DUCT LINE (RTU1 ONLY). #10 X 3/4" SELF TAPPING CADMIUM PLATED SHEET METAL SCREWS TO GENERAL CONTRACTOR'S RESPONSIBILITY TO STAY IN TOUCH WITH 2. INSTALL STRUCTURAL SUPPORT FOR NEW RTUs- < ANCHOR STRAPS To DUCT. THE YORK CONTACT AND TO SCHEDULE THE ACTUAL DATE THE SEE STRUCTURAL DRAWINGS. L-EI3. ROOF TOP UNIT ARE TO BE DELIVERED TO THE JOB SITE. < ALL STRAPS TO BE TIGHT AGAINST 3. IT IS EXPECTED THAT WHEN UNITS ARE DELIVERED THEY WILL INSTALL NEW RTUs AND CURBS PER PLAN. DUCT AND SUPPORT GO FROM TRUCK TO ROOF AND NOT BE LEFT ON THE GROUND. COORDINATE ROOF ACTIVITIES WITH LANDLORD M EMBERS. (TYPICAL) IF THE JOB SCHEDULE WILL NOT ACCOMMODATE THE ORIGINAL 1" RIGID INSULATION ON TH NO POP RIVETS ALLOWED REQUESTED DELIVERY DATE THEN THE GENERAL CONTRACTOR MUST ROOF CONTRACTOR. INSIDE OF THE DUCT CALL YORK AND RESCHEDULE. UNITS ARE NOT TO BE LEFT ON 4. INSTALL DUCTS, DIFFUSERS PER PLAN. USE DUCT -STRAP -HANGER THE GROUND WHERE THEY MAY BE SUBJECT TO DAMAGE. 1 DUCT STRAP HANGER DETAIL 4. WHEN UNITS ARRIVE THEY SHOULD BE INSPECTED FOR EXISTING DUCT MAIN LINES WHERE SHOWN. SET RTU RTU RTU 4 ELECTRICAL METERS DAMAGE, AS THE AUTOZONE POLICY ONLY ALLOWS THE GENERAL ALL DUCTS AS HIGH TO ROOF DECK AS POSSIBLE. 400 CFM ® 400 CFM ® FM 400 CFM ®� CONTRACTOR 72 HOURS TO REPORT DAMAGE OR ANY PROBLEM, 10x10 SAG 1OX10 SAG lox 0 SAG 1OX10 SAG 5. INSTALL RESTROOM EXHAUST THROUGH ROOF WITH oxloFs AFTER WHICH THE ISSUE BECOMES THE CONTRACTORS TO RESOLVE. IF THE DAMAGE IS SUPERFICIAL OR COSMETIC THEN 400 CFM c 10X10 SAG RAIN HOOD & BIRD SCREEN. �XISTING DUCT -- THE UNITS SHOULD BE ACCEPTED, INSTALLED AND REPAIRED IN RUNK TO EMAIN XISTK DUCT \ THE FIELD. I CTS THE I HE F THE ABEGNOTEDEON OF TNOTIFY 6. INSTALL ENERGY MANAGEMENT SYSTEM PER RUNK TO EMAIN UNT THEN IT SHOULD THE BILL OF LADNG,ON ELECTRICAL DRAWINGS. YORK TO SCHEDULE A REPLACEMENT AND PICK-UP, AND NOTIFY - THE AUTOZONE AFI MANAGER. SEE AUTOZONE AFI POLICY FOR EXISTING DIJI CT I4/ ADDITIONAL INFORMATION. I TRUNK TO EMAIN I I 5. CONTACTS: 11 TO SCHEDULE DELIVERY: SHONA STEPHENS 405-419-6272 TO REPORT DAMAGE: JESSICA RIBBLE 405-419-6676 II II CENTERLINE R = 1.5 X W FOR TECHNICAL SUPPORT: JASON MCDANIEL 405-419-6853 III AUTOZONE AFI MANAGER: LEW ELLIS 901-495-8707 RADIUS -ELBOW 1/81, = 1'-0" MHN07 II 400 cA I I II 10X10 SAGG 2 RADIUS ELBOW 9 YORK HVAC NOTES L 1. DOA (Dead on Arrival): LABOR ALLOWANCES APPLY ONLY TO I I � 400 CFM 11 400 CFM 400 CFM 400 CFM 400 CFM I 400CFM 1X10 SAO II 1OX10 SAG I 11OX10 SAG 1OX110 SAG 1OX10 SAG 10X110 SAG L = 1 /4 W, THOSE SITUATIONS WHERE DEFECTS HAVE OCCURRED DIRECTLY AS CONTRACTOR SHALL FURNISH AND INSTALL 4 MIN. A RESULT OF FACTORY WORKMANSHIP AND/OR MATERIALS. A REMOTE TEST AND INSPECT CONTROL REIMBURSEMENT ILL NOT BE ALLOWED HERE DAMAGE HAS BEEN W W W \ 1 ° FOR TESTING THE SMOKE DETECTORS. 101 SUSTAINED AS A RESULT OF MISAPPLICATION OR IMPROPER CONTRACTOR SHALL COORDINATE THE I I z W INSTALLATION. LOCATION WITH THE AUTHORITY HAVING 1 °� I 1 2. FOR ALL DOA AND ANY OTHER WARRANTY ISSUES THE ANEL "B" JURISDICTION AND THE AUTOZONE I I CONTRACTOR SHALL CALL THE YORK WARRANTY GROUP FOR PANEL "A" CONSTRUCTION COORDINATOR. 1 INSTRUCTIONS ON HOW TO PROCEED. YORK WILL RESPOND TO PANEL L RT 1 ALL WARRANTY REQUESTS OR ISSUES WITHIN 24 HOURS, PROCEEDING WITH WORK IN ADVANCE OF NOTIFYING YORK MAY 1OX10 SAG 400 CFM 45° RESULT IN CONTRACTOR NOT BEING REIMBURSED FOR ALL OF HIS 10X10 SAGI i � COSTS. 120x161 CLOSE OPENING AT CORNERS 3. AS YORK HAS PRE ASSIGNED LABOR VALUES TO ALL PARTS OF I THE ROOF TOP UNIT, CONTRACTOR MUST GET YORK'S 3 RECTANGULAR BRANCH DUCT TAKEOFF CONCURRANCE IN THE CONTRACTOR'S ESTIMATED LABOR CHARGE 400 CFM a SPUTTER TO DO THE WORK PRIOR TO COMMENCING, OR CONTRACTOR MUST DAMPER \ I 1ox1 SAG I 400 CFM 400 FM 400 CFM 400 FM 400 CFM 400 FM 1202 1X10 SA 1X1 SAG 10X10 SA 1OX10SAG 1OX10 SAG 1OX10SAG 400 CFM 400 'CFM PROVIDE NYLON o SEE PLANS FOR 90 BEARING ON RUNOUT SIZES AGREE TO YORK'S LABOR ALLOWANCE. PARTS WILL BE FURNISHED AT NO COST BY YORK, THEY MAY ASK CONTRACTOR TO RETURN 40o cFM \ 1X10 AG 400 SAG 1� SAG 1OX4. DAMPER SHAFT THE DEFECTIVE PART AND CONTRACTOR MUST DO SO. FOR EXPEDITED SERVICE CONTRACTOR SHOULD HAVE THE \\ \ 202 PROVIDE MANUAL MODEL AND SERIAL NUMBER OF THE UNIT IN QUESTION PRIOR TO I BUTTERFLY MAKING A CALL FOR WARRANTY SERVICE. V\ DAMPER IN 5. CONTACTS: \ BRANCH TAKEOFF FOR WARRANTY ISSUES: JESSICA RIBBLE 800-481-9738 OPTION 4 \\ PROVIDE FOR TECHNICAL SUPPORT: LEROY BERRY 800-481-9739 OPTION 4 _ _ _ _ STANDOFF 450 HVAC P LAN INSULATION 1/8" = 1'-0" BRACKET ON XSPIN-IN \\ INSULATED DUCTS FITTINGS W/SCOOPS ARE \\ NOT ACCEPTABLE 1/8" = 1'-0" MHN04 4 ROUND BRANCH DUCT TAKE -OFF 10 YORK WARRANTY NOTES FACTORY MOUNTED AND WIRED WEATHERPROOF J-BOX MOUNT MARK BRAND MODEL CFM @ 1 8 S.P. SONES ELEC. REQUIREMENT 1. All air diffusers and return air grills are new, to be supplied NON -FUSED DISCONNECT TO NORTH FACING SIDE OF and installed by the general contractor. TEF-1 BROAN 503 160 5 120V-1 PH-60HZ EXTERIOR TEMP. SENSOR TO CONTROLS IN RTU RTU. MOUNT LCP PHOTOCELL CONVENIENCE OUTLET BY ELECTRICAL CONTRACTOR SUPPLIED TO J-BOX AND WIRE THRU WEATHER-PROOF GFI CONVENIENCE UNIT TO J-BOX AT DECK TEF-2 BROAN 503 160 5 120V-1 PH-60HZ LEGEND FOR NEW GRILLES CONTRACTOR. SEE SHEET E1. OUTLET (ONE PER RTU) BELOW. INDICATES ROOF OPENING Fm INTERLOCK EXHAUST FANS WITH LIGHTING CONTROLS ECONOMIZER 24"x24" or 24"x48" RETURN AIR CLG. ELJ GRILLS TITUS MODEL # 50F, T-BAR FLASHING AND FIBER CONDENSATE DRAIN LAY -IN. R/A= SEE PLAN BYEGTCICAL DISCONNECT PROVIDED CANT STRIP AT CANT STRIP MECHANICAL ROOF CURB (ROOF CURB FURNISHED BY RTU SUPPLIER) REFER TO STRUCTURAL PLANS FOR PROPER ROOF CURB SMOKE DETECTOR IS FACTORY RTU ROOF DECK TU 0 MOUNTED IN THE RETURN AIR _ M OUNTER- FLASHING BY \� GENERAL CONTRACTOR SIDE WALL GRILLE, TITUS MODEL # 300 WITH - SAG DOUBLE DEFLECTION, FRONT BLADES SHALL BE PARALLEL WITH WIDTH SEE PLAN FOR SECTION OF THE ROOFTOP S SIZE AND AIR MOUNTING DETAILS. UNIT. 1 PAIR 18 GAUGE, Temp SHIELDED CABLE BETWEEN S- 1/8" = 1'-0" hvac-legend METAL STRAP RETURN SMOKE DETECTOR AND RTU I � STRAP ANCHORS 7 M L ET EXHAUST FAN SCHEDULE 11 HVAC L E G E N D AIR CONTROLS / \ �P RENR SIDE VIE SURLY RTU ANGLE FRAME MARK MANUFACTURER MODEL NO. SUPPLY AIR MIN. O.S.A. COOLING DATA HEAT PUMP ELECTRICAL REQ. UNIT M.C.A. BREAKER TOTAL COOLING EER ENT. AIR D.B. .B. SEE HVAC PLAN SUPPLY CAI END VIEW SEE STRUCTURAL NEW/EXISTING E.S.P. SENSIBLE COOLING D.B. OUTPUT @ 47 DEG FOR DUCT 6 MM SENSOR TUBE REMOTE TEMP SENSOR IS FACTORY DRAWINGS RTU-1 YORK 2,400 CFM 80 67 71,000 BTU 12.0 70 208/34/6OHz 50A ROUTING. KEEP SUPPLY AIR DUCT INSTALLED AND CAN BE FOUND IN XYE07 NEW 425 CFM 0.25 IN. 55,000 BTU 67,000 BTU 34.3 MAIN TRUNK AS THE FILTER SECTION. MOUNT RTU-2 YORK XYE07 2,400 CFM 425 CFM 80 67 71,000 BTU 55,000 BTU 12.0 70 67,000 BTU 208/34/6OHz 34.3 50A HIGH AS POSSIBLE. HORN STROBE UNIT / BRACKET ON BOTTOM OF RETURN J-BOX AT DECK FOR RTU AIR NOTE: CONTROL WIRING FOR SENSOR TUBE LOCATION DUCT CLOSE TO SUPPLY SIDE. POWER & CONTROLS SEE EXTEND WIRE FROM SENSOR THRU EACH RTU MUST BE RUN IN E-1 FOR CONDUIT SIZE NEW 0.25 IN. RTU-3 YORK 2,400 CFM 80 67 71,000 BTU 12.0 70 208/30/6OHz 50A JUNCTION BOX AND CONDUIT MOUNTED TO DECK PER NEC DUCT AND INSERT THRU TUBE AND SEPARATE CONDUIT. SEE MAKE CONNECTIONS THRU HUB PROVIDED LEAVE 1/4" STICKING BELOW SHEET E-6 FOR ADDITIONAL XYE07 425 CFM 55,000 BTU 67,000 BTU 34.3 BOTTOM OF TUBE. INFORMATION. IN BOTTOM OF THE RTU. DO NOT CUT NEW 0.25 IN. SMOKE DETECTOR IS FACTORY MOUNTED IN THE RETURN AIR SECTION PAN TO GAIN ACCESS. ALL CONNECTIONS 18 GAUGE 4 CONDUCTOR UNSHIELDED BETWEEN RTU-4 YORK 2,400 CFM 80 67 71,000 BTU 12.0 70 208/34/6OHz 50A OF THE ROOFTOP UNIT. SEE MANUFACTURER'S SPECIFICATIONS. INSIDE OF RTU TO BE WEATHERPROOF. RTU CONTROLS AND T-STAT. 18 GAUGE 3 XYE07 425 CFM 55,000 BTU 67,000 BTU 34.3 NEW 0.25 IN. CONDUCTOR BETWEEN TEMP SENSOR AND RTU WIRE MOUNTED REMOTE TEMPERATURE SENSOR PROBE INSIDE RETURN AIR DUCT, EXTEND CONTROLS. RUN ALL CABLE IN 1/2" CONDUIT. ROOFTOP UNITS SHALL HAVE ECONOMIZERS. WIRE THROUGH SENSOR TUBE. LET WIRE HANG 1 /4" BELOW BOTTOM OF TUBE. No Scale MH102 No Scale MHS01 1/8" = 1'-0" rtu-sched 5 ROOFTOP UNIT - VIEW OF RTU 16 ROOF CURB 18 ROOF TOP UNIT SCHEDULE Ln (-o N O N cry � 0 O O C/-) W � N � U) J � Q d' co w 0 U) J L.L L L1 O (0 O C') z O Z = z (1) w Q O U)z 0 J N - LU aU N z Q O � > QZ3 00 LL = 00 O 4 U 00 0C kA U U U r--, 0Iosl,� `$1,,,, rrr�i, `.� � EUGENF ''% ��aEAfS* �0 F' No. 35785 �,,�1 1 -� • STAT OF 05/28/2021 57N-REMODEL