HomeMy WebLinkAboutFL3607-P1-PLUMBING-ModelC 1. DIG HOLE FOR HYDRANT APPROXIMATELY 2 FEET IN DIAMETER N.F.H.B. ABOVE ROOF, �I 4" VENT PIPE PLUMBING NOTES: AND DEEPER THAN THE BURY DEPTH. ROUTE CHECK VALVE FLASHING TO BE COMPATIBLE DESIGN PARAMET S 4" VENT THRU DRAIN TO MOP SINK. W/ ROOF MEMBRANE. 2. FLUSH GRAVEL, DEBRIS, ETC, OUT OF THE SUPPLY LINE BEFORE CONNECTING HYDRANT. ROOF I ROOF MEMBRANE ___,, 1 1. PLUMBING CODE: FLORIDA STATE BUILDING CODE: FLORIDA BUILDING CODE 2020 7TH EDITION 3. INSTALL HYDRANT WITH DRAIN HOLE BELOW FROST LINE. / / \ FLASHING STRIP `� 2. PLUMBING OCCUP Y A IC N: ercan i e USE WRENCHES ON SUPPLY LINE FITTING AND BRASS / I -11/2 VENT BUILDING AREA FOR OCCUPANCY - See Sheet A-0 for area BODY VALVE ONLY. THIS AVOIDS OVER TIGHTENING THE HYDRANT ASSEMBLY WHICH COULD AFFECT OPPERATION. 1-1/2 VENT / / I OCCUPANT LOAD - See Sheet A-0 for occupancy 4. IF SUPPLY LINE TO THE HYDRANT WILL NOT SUPPORT / 4"I MIN. 4" TO / /I METAL DECK / FIXTURE REQUIREMENTS: HYDRANT, USE RE -BAR, LENGTH OF PIPE OR OTHER SUITABLE / SANITARY SEWER. / ROOF INSULATION WATER CLOSETS - 1 per 500 people SUPPORT DRIVEN IN BOTTOM OF PIT TO HELP SUPPORT I I SEE SITE PLA / NOTE: FOR SINGLE PLY ROOF LAVATORY - 1 per 750 people HYDRANT. BEFORE FILLING EXCAVATION, TURN ON WATER AND MEMBRANES PROVIDE PREFABRICATED CHECK HYDRANT CONNECTION FOR LEAKS. I GRADE / 1-1 /2" VENT 1" — 1'-0" PIPE BOOTS TO MATCH MEMBRANE. PPS01 DRINKING FOUNTAIN - 1 per 1000 people 5. PROVISIONS MUST BE MADE TO ALLOW THE WATER TO DRAIN 1+1/2" VENT I CLEANOUT I I — SERVICE (MOP) SINK 1 per store 3 �VENT STACK DETAIL_ FROM THE HYDRANT DRAIN HOLE EACH TIME THE HYDRANT IS 4 3. SEPARATE FACILITIES ARE REQUIRED FOR MEN AND WOMEN. THERE IS 1 WATER CLOSET AND 1 LAVATORY FOR EACH RESTROOM, CLOSED. 1-1/2 VENT I I WC. I I PAVING OR GRADE LINE IF REQUIRED BY CODE, THERE SHOULD BE 1 URINAL IN THE MEN'S RESTROOM. (A) IF THE HYDRANT IS TO BE INSTALLED IN A CONCRETE 3 1-1/2" ENT I (SEE SITE PLAN) DRIVEWAY, CONNECT 1/8 INCH COPPER DRAIN TUBING TO THE I ELECTRIC DRINK 4 3 GENERAL PLUMBING OTES• NN DRAIN HOLE AND DIG A REMOTE DRAIN FIELD FOR THE DRAIN PIPE TO EMPTY INTO. WC FOUNTAIN MOUNT PER I �� I 12" X 12" X 9" A. PIPE MATERIAL SHALL BE AS FOLLOWS: (B) STAURATED GROUND IN THE HYDRANT DRAIN FIELD CAN "ADA" REQUIREMENTS LAV. I LAV. 4" CONCRETE PAD `' SOIL, WASTE AND VENT (INSIDE BLDG.) ASTM D2665 PVC-DWV WITH NSF SEAL PREVENT THE HYDRANT FROM DRAINING AND MAY RESULT IN WALL CLEANOUT I - SOIL AND WASTE (OUTSIDE BLDG.) ASTM D3034 PVC THE HYDRANT FREEZING. IF THE AREA WHERE THE HYDRANT IS LOCATED IS LOW LYING OR HAS A TENDENCY TO HAVE UNDER ELECTRIC 2 DRINK FOUNTAIN GRADE CLEANOUT - _III III I III_ DOMESTIC WATER (UNDER SLAB) PEX PIPE SEE SPECIFICATIONS STANDING WATER, A LARGER DRAIN FIELD OR PIT MAY BE 2 REQUIRED TO PROVIDE THE HYDRANT A PLACE TO DRAIN. TERMINATE ROOF BPIDOMESTIC II d WATER (INSIDE ABOVE SLAB) PEX PIPE SEE SPECIFICATIONS (C) FILL BOTTOM OF PIT WITH 1/2 INCH GRAVEL TO A LEVEL FLOOR CLEANOUT TO REPLACE WALL CLEAN- OUT ONLY WHEN REQUIRED MOP SINK HYDRANT DRAIN A REFER TO RISER FOR WASTE I _ Ii DOMESTIC WATER MAIN (TO WITHIN 5' OF BLDG.) PEX PIPE SEE SPECIFICATIONS 3 INCHES ABOVE BRASS DRAIN VALVE BODY TO INSURE BY CODE. MINIMUN OF 2" ABOVE 4) LINE (MINIMUM FROM ' ' NATURAL GAS ASTM A120, SCHEDULE 40 BLACK STEEL WITH ADEQUATE DRAINAGE. THE FLOOD RIM OF BUILDING FACTORY APPLIED PROTECTIVE COATING FOR 1/8" = 1'-0" PPN02 1/8" - 1'-0" THE MOP SINK. PP101R 1/2" = 1'-0" PPS02 UNDERGROUND APPLICATION. 1 YARD HYDRANT N STAL_L_ATI O N 2 PLUMBING WASTE/VENT RISER 4 GRADE CLEANOUT CONDENSATE PVC, SOLVENT WELDED B. THE PIPE INSULATION SHALL BE AS FOLLOWS: DW = DOMESTIC WATER 3/4" DW TO DHW = DOMESTIC HOT WATER FREEZE -PROOF HYDRANT 1. HOLD 4" SANITARY VENT THRU ROOF TIGHT AGAINST EXTERIOR LAV. = LAVATORY ABOVE ROOF WALL BETWEEN TOILET CEILING AND BOTTOM OF ROOF 3/4„ HOSE WC. = WATER CLOSET STRUCTURE. OFFSET VENT A MINIMUM OF 12 FROM FACE OF DOMESTIC COLD WATER 1/2" POLYOLEFIN CLOSED CELL CONNECTION EDF. = ELECTRIC DRINKING FOUNTAIN WATER CUTOFF VALVE WALL BEFORE PENETRATING ROOF DECK. DOMESTIC HOT WATER ABOVE GRADE -SAME AS COLD WATER PROVIDE 1 R. 2. MOUNT MAIN CUTOFF AT 24 A.F.F. IN RESTROOM, AS INDICATED ON ARCHITECTURAL ELEVATIONS. BELOW GRADE - 3/8" CLOSED CELL SUITABLE NOTTEE 5 3/4" ACCESS DOOR. N 5 3/4" DW TO FOR UNDERGROUND USE 3. SEE SITE PLAN TO VERIFY LANDSCAPE CONNECTION FREEZE -PROOF YARD REQUIREMENTS AND LOCATIONS. HYDRANT NOTES 6 & 7 \+� ���� CONDENSATE (INSIDE BUILDING) 1/2" POLYOLEFIN CLOSED CELL 1" GALVANIZED 4. BACKFLOW PREVENTER IF REQUIRED BY LOCAL CODE TO PIPE \ 27 1/2" `\ ' 1" LINE FROM WATER SERVICE BE INSTALLED INSIDE THE BUILDING - SEE GENERAL MINIMUM 3/ 4" PROVIDE WATER METER AS REQUIRED PLUMBING NOTES: NOTE "ID". C. THE ELECTRIC WATER HEATER WILL BE A MINITANK, BOSCH MODEL ES-41 M, FURNISHED BY AUTOZONE FOR ` `DW BY LOCAL UTILITY. 1 5. PROVIDE CUT-OFF IN A RECESSED ACCESS BOX IN RESTROOM INSTALLATION BY THE CONTRACTOR. GROUND \`\ DHW r WHERE INDICATED ON THE DRAWINGS FOR THE 3/4" WATER LEVEL - LINE THAT FEEDS THE YARD HYDRANT OR HOSE BIBB IF D. A BACKFLOW PREVENTER SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR, WHEN REQUIRED BY LOCAL CODE. „ 3/4 REQUIRED. T HE BACKFLOW PREVENTER SHALL BE A REDUCED PRESSURE ZONE TYPE, WATTS 909 SERIES. INSTALL THE BACKFLOW PREVENTER IN ACCORDANCE WITH LOCAL CODE. IF BACKFLOW PREVENTER IS INSTALLED INSIDE THE BUILDING, ROUTE 1 �` 6 IF CALLED FOR ON THE DRAWINGS, INSTALL FREEZELESS THE DRAIN IN THE WALL TO THE MOP SINK AND TERMINATE ABOVE THE FLOOD RIM OF THE SINK. ` WC tiX �� WC 1� IOWA YARD HYDRANT MODEL Y 34 AS MANUFACTURED BY E. THE WATER CLOSET SHALL BE A 1.6 GALLON PER FLUSH, MAXIMUM. 1" � �� � WOODFORD MANUFACTURING COMPANY OR ANON -FREEZE BURY DEPTH HOSE BIBB. HYDRANT SHALL BE LOCATED IN A GRASS OR F. THE LAVATORY FAUCET SHALL HAVE A MAXIMUM FLOW RATE OF 1.0 GPM. THE HANDLES SHALL BE ALL BRASS AND 2'-0" MINIMUM 1� LANDSCAPE AREA SEE CIVIL DRAWINGS FOR EXACT HANDICAP ACCESSIBLE. N LAV. 1» DIMENSIONAL LOCATION, HOSE BIBB SHALL BE LOCATED LAV. Imo_ BACKFLOW PREVENTER ON AN EXTERIOR WALL NEAR THE SERVICE ENTRANCE. G. THE MOP SINK SHALL BE FLOOR MOUNTED, THE FAUCET SHALL HAVE AN INTEGRAL VACUUM BREAKER AND BUCKET HOOK. FROST LINE % (RPZ) WATER CUTOFF VALVE SINGLE 3/4" H. ALL ABOVE GROUND WATER SUPPLY PIPING SHALL BE INSULATED. DRAIN VALVE � WATER HEATER: PROVIDE 3/4 POINT OF ENTRY PROVIDE 7. INSTALL YARD HYDRANT IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED INSTRUCTIONS INCLUDING PROVIDING I. FLOOR DRAINS SHALL BE PROVIDED ONLY WHEN REQUIRED BY CODE. 10 X10 MILCOR ACCESS DOOR. COPPER AT OP � / EDF. '�� UNIONS NOTE 2 SINK VERTICAL SUPPORT AND A BELOW GRADE DRAIN FIELD FOR J. PROVIDE WATTS SERIES SHOCK ABSORBERS AT ALL QUICK CLOSING VALVES WHERE APPLICABLE. WATER LINES YARD HYDRANT TO EMPTY INTO EACH TIME THE HYDRANT IS LINEWATER LINE CLOSED. K. SHUT OFF VALVES SHALL BE INSTALLED FOR EACH PLUMBING FIXTURE. MAKE ALL TRANSITIONS ABOVE FINISHED FLOOR LINE 1 1/2" = 1'-0" PPS03 1/8" = 1'-0" NOTE ALL PIPING TO BE PEX PIPING SEE SPECIFICATIONS PP102R 1/8" = 1'-0" PPN01 1/8" = 1'-0$' PGN01 5 YARD HYDRANT 6 PLUMBING WATER RISER 7 KEYED PLUMBING NOTES 8 PL_UMBING NOTES WATER METER AND BACKFLOW FIXTURE DIM. REMARKS PREVENTER TO BE FURNISHED AND 19" TOP OF INSTALLED AS REQUIRED BY LOCAL AMERICAN TOILET SEATS (ACCESSIBLE) 17 SEAT MAX. IOWA ° URINALS (WHEN REQ D) WATER CUT OFF VALVES IN AUTHORITY. RECESSED ACCESS BOX. STANDARD KOHLER ELJER NON -FREEZE HYDRANT 1" LINE (ACCESSIBLE) 17" TO RIM 3/4" HOSE FROM BACKFLOW PREVENTER CONNECTION "CADET SERVICE ENTRANCE. P-1 TOILET (ELONGATED 3" #2386.800 R.H. LAVATORIES (ACCESSIBLE) 34 TO RIM, 29" MIN. TO BOTTOM 9" APRON INSULATED >' 6'— 9 P3 WATER 3/4)) HEATER 60" HANDICAP)1.6 GPF CADET 3 #2386.012 L.H. "HIGHLINE" #K-3427 "PATRIOT" #091-2175 NOTE: TOILET TANK TRIP LEVER TO BE LOCATED ON LAVATORY SIDE OF TANK. PIPING BOOT FLASHING SEAL WATER COOLER (ACCESSIBLE) 36 TO SPOUT DW DOMESTIC ABOVE TO PIPE AND ROOF WATER LINE FINISHED P1 P-2 LAVATORY "LUCERNE" "GREENWICH" "DELWYN" WATER HEATER 60„ A.F.F. TO BOTTOM OF HEATER MEMBRANE - N ROOF TO YARD FLOOR TO 0355.012 2032 051-1634 ROOF MEMBRANE P3HYDRANT. DH P2 BOTTOM INSULATION MOEN #8800, 4 INCH CENTERS, 4 INCH WRIST BLADE WITH 1/4 TURN HANDLES, WASHERLESS Y4) FAUCET AND MOEN #52602 1 GALLON PER MINUTE FLOW REDUCER. CONTRACTOR SHALL 1/8" = 1'-0" PPC01CARTRIDGES, ` ������ METAL DECK 12 M0UNTING HEIGHT SCHEDULE —4" P4 FURNISH AND INSTALL A WATTS LFMMV- MIXING VALVE TO SERVE THE FAUCETS (SET TO 110 F). CALL DRAIN MOEN "52660, OFFSET CHROME PLATED TAILPIECE, HOT WATER COLD WATER P2 OUT oo P2 P47 P1 EXPANSION TANK — o� P-3 SERVICE SINK FIAT #MSB-2424 OR MUSTEE #63 ACUUM RELIEF VALVE V I SUPPORT N SHALL BE LOCATED ON ACCORDANCE WITH „ CHECK INSTALL 1.5 SQUARE GCO THE COLD WATER INLET CODE. � VALVE DRAIN FAUCET MOEN �8124 ATERILSOLATHEATER IIEH UNISTRUT BETWEEN P2 P1 NTO O IONS BETWEEN IT AND THE HOT T & P VALVE JOISTS AND CLAMP ROUTE K MOP SINK. 1 —11 P2 o HWD � — P 4 WATER FOUNTAIN W HANDICAP ACCESSIBLE DUAL HEIGHT: ELKAY EZTL-8C OR HALSEY TAYLOR HTV8BL-Q WATER STORAGE TANK. WATER T & P DRAIN HEATER PIPE TO UNISTRUT. INSURE THE HYDRANT a - HEAT TRAP PIPE FULL SIZE TO MOP SINK. PIPING IS VERTICAL AND WELL ANCHORED 3/4" WATER LINE TERMINATE 2" DW =DOMESTIC WATER DRAIN PAN ABOVE FLOOD RIMOF SINK. DHW = DOMESTIC HOT WATER P2 PAN DRAIN 3/16" = 1'-0" PPP01R 3/16" = 1'-0" PPP02R MOP SINK 1 1/2" = 1'-0" PPSO4 1/8" = 1'-0" PPCO2 9 RESTROOM SEWER PLAN 110JRESTROOV WATER PLAN 11 PLUMBING FIXTURE SCHEDULE 13 WATER HEATER INSTALLATION 14 ROOF HYDRANT U) J Ln Q0 Q W 0 W N o O I z z O I W O U-)o w 'J 0 W U U) w 0) C X LL LL \ ti z cM Q O Z = L_ � W CD � � Z � Z W Cm G O Z OCV 1171yo O 000 Q d' L.L d- cio 0O o U 00 00 c Ln ct 4-1 O U ct Q o�losl �� �o ••�GENS. 35785 IK STAT OF OR 05/28/2021 57N—REMODEL