HomeMy WebLinkAboutFL3607-P1-PLUMBING-ModelC
1. DIG HOLE FOR HYDRANT APPROXIMATELY 2 FEET IN DIAMETER
N.F.H.B. ABOVE ROOF,
�I
4" VENT PIPE
PLUMBING NOTES:
AND DEEPER THAN THE BURY DEPTH.
ROUTE CHECK VALVE
FLASHING TO BE COMPATIBLE
DESIGN PARAMET S
4" VENT THRU DRAIN TO MOP SINK.
W/ ROOF MEMBRANE.
2. FLUSH GRAVEL, DEBRIS, ETC, OUT OF THE SUPPLY
LINE BEFORE CONNECTING HYDRANT.
ROOF I
ROOF MEMBRANE ___,, 1
1. PLUMBING CODE: FLORIDA STATE BUILDING CODE: FLORIDA BUILDING CODE 2020 7TH EDITION
3. INSTALL HYDRANT WITH DRAIN HOLE BELOW FROST LINE.
/
/ \
FLASHING STRIP `�
2. PLUMBING OCCUP Y A IC N: ercan i e
USE WRENCHES ON SUPPLY LINE FITTING AND BRASS
/ I -11/2 VENT
BUILDING AREA FOR OCCUPANCY - See Sheet A-0 for area
BODY VALVE ONLY. THIS AVOIDS OVER TIGHTENING THE
HYDRANT ASSEMBLY WHICH COULD AFFECT OPPERATION.
1-1/2 VENT / / I
OCCUPANT LOAD - See Sheet A-0 for occupancy
4. IF SUPPLY LINE TO THE HYDRANT WILL NOT SUPPORT
/ 4"I MIN. 4" TO /
/I
METAL DECK /
FIXTURE REQUIREMENTS:
HYDRANT, USE RE -BAR, LENGTH OF PIPE OR OTHER SUITABLE
/ SANITARY SEWER. /
ROOF INSULATION
WATER CLOSETS - 1 per 500 people
SUPPORT DRIVEN IN BOTTOM OF PIT TO HELP SUPPORT
I I SEE SITE PLA /
NOTE: FOR SINGLE PLY ROOF
LAVATORY - 1 per 750 people
HYDRANT. BEFORE FILLING EXCAVATION, TURN ON WATER AND
MEMBRANES PROVIDE PREFABRICATED
CHECK HYDRANT CONNECTION FOR LEAKS.
I GRADE / 1-1 /2" VENT
1" — 1'-0" PIPE BOOTS TO MATCH MEMBRANE. PPS01
DRINKING FOUNTAIN - 1 per 1000 people
5. PROVISIONS MUST BE MADE TO ALLOW THE WATER TO DRAIN
1+1/2" VENT I CLEANOUT
I I
—
SERVICE (MOP) SINK 1 per store
3
�VENT STACK DETAIL_
FROM THE HYDRANT DRAIN HOLE EACH TIME THE HYDRANT IS
4
3. SEPARATE FACILITIES ARE REQUIRED FOR MEN AND WOMEN. THERE IS 1 WATER CLOSET AND 1 LAVATORY FOR EACH RESTROOM,
CLOSED.
1-1/2 VENT I I WC. I I
PAVING OR GRADE LINE
IF REQUIRED BY CODE, THERE SHOULD BE 1 URINAL IN THE MEN'S RESTROOM.
(A) IF THE HYDRANT IS TO BE INSTALLED IN A CONCRETE
3 1-1/2" ENT
I
(SEE SITE PLAN)
DRIVEWAY, CONNECT 1/8 INCH COPPER DRAIN TUBING TO THE
I
ELECTRIC DRINK 4 3
GENERAL PLUMBING OTES•
NN
DRAIN HOLE AND DIG A REMOTE DRAIN FIELD FOR THE DRAIN
PIPE TO EMPTY INTO.
WC
FOUNTAIN MOUNT PER I ��
I
12" X 12" X 9"
A. PIPE MATERIAL SHALL BE AS FOLLOWS:
(B) STAURATED GROUND IN THE HYDRANT DRAIN FIELD CAN
"ADA" REQUIREMENTS LAV.
I LAV. 4"
CONCRETE PAD
`'
SOIL, WASTE AND VENT (INSIDE BLDG.) ASTM D2665 PVC-DWV WITH NSF SEAL
PREVENT THE HYDRANT FROM DRAINING AND MAY RESULT IN
WALL CLEANOUT
I
-
SOIL AND WASTE (OUTSIDE BLDG.) ASTM D3034 PVC
THE HYDRANT FREEZING. IF THE AREA WHERE THE HYDRANT
IS LOCATED IS LOW LYING OR HAS A TENDENCY TO HAVE
UNDER ELECTRIC 2
DRINK FOUNTAIN
GRADE CLEANOUT -
_III III I III_
DOMESTIC WATER (UNDER SLAB) PEX PIPE SEE SPECIFICATIONS
STANDING WATER, A LARGER DRAIN FIELD OR PIT MAY BE
2
REQUIRED TO PROVIDE THE HYDRANT A PLACE TO DRAIN.
TERMINATE ROOF
BPIDOMESTIC
II d
WATER (INSIDE ABOVE SLAB) PEX PIPE SEE SPECIFICATIONS
(C) FILL BOTTOM OF PIT WITH 1/2 INCH GRAVEL TO A LEVEL
FLOOR CLEANOUT TO REPLACE WALL
CLEAN- OUT ONLY WHEN REQUIRED MOP SINK HYDRANT DRAIN A
REFER TO RISER FOR WASTE I _ Ii
DOMESTIC WATER MAIN (TO WITHIN 5' OF BLDG.) PEX PIPE SEE SPECIFICATIONS
3 INCHES ABOVE BRASS DRAIN VALVE BODY TO INSURE
BY CODE. MINIMUN OF 2" ABOVE
4)
LINE (MINIMUM FROM ' '
NATURAL GAS ASTM A120, SCHEDULE 40 BLACK STEEL WITH
ADEQUATE DRAINAGE.
THE FLOOD RIM OF
BUILDING
FACTORY APPLIED PROTECTIVE COATING FOR
1/8" = 1'-0" PPN02
1/8" - 1'-0" THE MOP SINK. PP101R
1/2" = 1'-0" PPS02
UNDERGROUND APPLICATION.
1
YARD HYDRANT N STAL_L_ATI O N
2
PLUMBING WASTE/VENT RISER
4
GRADE CLEANOUT
CONDENSATE PVC, SOLVENT WELDED
B. THE PIPE INSULATION SHALL BE AS FOLLOWS:
DW = DOMESTIC WATER 3/4" DW TO
DHW = DOMESTIC HOT WATER FREEZE -PROOF HYDRANT
1. HOLD 4" SANITARY VENT THRU ROOF TIGHT AGAINST EXTERIOR
LAV. = LAVATORY ABOVE ROOF
WALL BETWEEN TOILET CEILING AND BOTTOM OF ROOF
3/4„ HOSE
WC. = WATER CLOSET
STRUCTURE. OFFSET VENT A MINIMUM OF 12 FROM FACE OF
DOMESTIC COLD WATER 1/2" POLYOLEFIN CLOSED CELL
CONNECTION
EDF. = ELECTRIC DRINKING FOUNTAIN
WATER CUTOFF VALVE
WALL BEFORE PENETRATING ROOF DECK.
DOMESTIC HOT WATER ABOVE GRADE -SAME AS COLD WATER
PROVIDE 1 R.
2. MOUNT MAIN CUTOFF AT 24 A.F.F. IN RESTROOM, AS
INDICATED ON ARCHITECTURAL ELEVATIONS.
BELOW GRADE - 3/8" CLOSED CELL SUITABLE
NOTTEE 5
3/4" ACCESS DOOR. N 5
3/4" DW TO
FOR UNDERGROUND USE
3. SEE SITE PLAN TO VERIFY LANDSCAPE CONNECTION
FREEZE -PROOF YARD
REQUIREMENTS AND LOCATIONS.
HYDRANT NOTES 6 & 7 \+� ����
CONDENSATE (INSIDE BUILDING) 1/2" POLYOLEFIN CLOSED CELL
1" GALVANIZED
4. BACKFLOW PREVENTER IF REQUIRED BY LOCAL CODE TO
PIPE \ 27 1/2"
`\ ' 1" LINE FROM WATER SERVICE
BE INSTALLED INSIDE THE BUILDING - SEE GENERAL
MINIMUM
3/ 4" PROVIDE WATER METER AS REQUIRED
PLUMBING NOTES: NOTE "ID".
C. THE ELECTRIC WATER HEATER WILL BE A MINITANK, BOSCH MODEL ES-41 M, FURNISHED BY AUTOZONE FOR
` `DW BY LOCAL UTILITY.
1
5. PROVIDE CUT-OFF IN A RECESSED ACCESS BOX IN RESTROOM
INSTALLATION BY THE CONTRACTOR.
GROUND
\`\
DHW r
WHERE INDICATED ON THE DRAWINGS FOR THE 3/4" WATER
LEVEL -
LINE THAT FEEDS THE YARD HYDRANT OR HOSE BIBB IF
D. A BACKFLOW PREVENTER SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR, WHEN REQUIRED BY LOCAL CODE.
„
3/4
REQUIRED.
T HE BACKFLOW PREVENTER SHALL BE A REDUCED PRESSURE ZONE TYPE, WATTS 909 SERIES. INSTALL THE BACKFLOW
PREVENTER IN ACCORDANCE WITH LOCAL CODE. IF BACKFLOW PREVENTER IS INSTALLED INSIDE THE BUILDING, ROUTE
1 �`
6 IF CALLED FOR ON THE DRAWINGS, INSTALL FREEZELESS
THE DRAIN IN THE WALL TO THE MOP SINK AND TERMINATE ABOVE THE FLOOD RIM OF THE SINK.
`
WC tiX ��
WC 1�
IOWA YARD HYDRANT MODEL Y 34 AS MANUFACTURED BY
E. THE WATER CLOSET SHALL BE A 1.6 GALLON PER FLUSH, MAXIMUM.
1" � �� �
WOODFORD MANUFACTURING COMPANY OR ANON -FREEZE
BURY DEPTH
HOSE BIBB. HYDRANT SHALL BE LOCATED IN A GRASS OR
F. THE LAVATORY FAUCET SHALL HAVE A MAXIMUM FLOW RATE OF 1.0 GPM. THE HANDLES SHALL BE ALL BRASS AND
2'-0" MINIMUM
1�
LANDSCAPE AREA SEE CIVIL DRAWINGS FOR EXACT
HANDICAP ACCESSIBLE.
N
LAV. 1»
DIMENSIONAL LOCATION, HOSE BIBB SHALL BE LOCATED
LAV. Imo_ BACKFLOW PREVENTER
ON AN EXTERIOR WALL NEAR THE SERVICE ENTRANCE.
G. THE MOP SINK SHALL BE FLOOR MOUNTED, THE FAUCET SHALL HAVE AN INTEGRAL VACUUM BREAKER AND BUCKET HOOK.
FROST LINE
% (RPZ) WATER CUTOFF VALVE SINGLE
3/4"
H. ALL ABOVE GROUND WATER SUPPLY PIPING SHALL BE INSULATED.
DRAIN VALVE
� WATER HEATER: PROVIDE 3/4 POINT OF ENTRY PROVIDE
7. INSTALL YARD HYDRANT IN STRICT ACCORDANCE WITH
MANUFACTURER'S PRINTED INSTRUCTIONS INCLUDING PROVIDING
I. FLOOR DRAINS SHALL BE PROVIDED ONLY WHEN REQUIRED BY CODE.
10 X10 MILCOR ACCESS DOOR.
COPPER AT OP �
/
EDF. '�� UNIONS NOTE 2
SINK
VERTICAL SUPPORT AND A BELOW GRADE DRAIN FIELD FOR
J. PROVIDE WATTS SERIES SHOCK ABSORBERS AT ALL QUICK CLOSING VALVES WHERE APPLICABLE.
WATER LINES
YARD HYDRANT TO EMPTY INTO EACH TIME THE HYDRANT IS
LINEWATER
LINE
CLOSED.
K. SHUT OFF VALVES SHALL BE INSTALLED FOR EACH PLUMBING FIXTURE.
MAKE ALL TRANSITIONS ABOVE FINISHED FLOOR LINE
1 1/2" = 1'-0" PPS03
1/8" = 1'-0" NOTE ALL PIPING TO BE PEX PIPING SEE SPECIFICATIONS PP102R
1/8" = 1'-0" PPN01
1/8" = 1'-0$' PGN01
5
YARD HYDRANT
6
PLUMBING WATER RISER
7
KEYED PLUMBING NOTES
8
PL_UMBING NOTES
WATER METER AND BACKFLOW
FIXTURE
DIM.
REMARKS
PREVENTER TO BE FURNISHED AND
19" TOP OF
INSTALLED AS REQUIRED BY LOCAL
AMERICAN
TOILET SEATS (ACCESSIBLE)
17
SEAT MAX.
IOWA °
URINALS (WHEN REQ D)
WATER CUT OFF VALVES IN AUTHORITY.
RECESSED ACCESS BOX.
STANDARD
KOHLER
ELJER
NON -FREEZE
HYDRANT
1" LINE
(ACCESSIBLE)
17"
TO RIM
3/4" HOSE
FROM BACKFLOW PREVENTER
CONNECTION
"CADET
SERVICE
ENTRANCE.
P-1 TOILET (ELONGATED
3" #2386.800 R.H.
LAVATORIES (ACCESSIBLE)
34
TO RIM, 29" MIN. TO
BOTTOM 9" APRON
INSULATED
>'
6'— 9
P3
WATER
3/4))
HEATER 60"
HANDICAP)1.6 GPF
CADET 3 #2386.012 L.H. "HIGHLINE" #K-3427 "PATRIOT" #091-2175
NOTE: TOILET TANK TRIP LEVER TO BE LOCATED ON LAVATORY SIDE OF TANK.
PIPING
BOOT FLASHING SEAL
WATER COOLER (ACCESSIBLE)
36
TO SPOUT
DW
DOMESTIC ABOVE
TO PIPE AND ROOF
WATER LINE FINISHED
P1
P-2 LAVATORY
"LUCERNE"
"GREENWICH"
"DELWYN"
WATER HEATER
60„
A.F.F. TO BOTTOM
OF HEATER
MEMBRANE - N
ROOF
TO YARD FLOOR TO
0355.012
2032
051-1634
ROOF
MEMBRANE
P3HYDRANT.
DH P2
BOTTOM
INSULATION
MOEN #8800, 4 INCH CENTERS, 4 INCH WRIST BLADE WITH 1/4 TURN HANDLES, WASHERLESS
Y4)
FAUCET
AND MOEN #52602 1 GALLON PER MINUTE FLOW REDUCER. CONTRACTOR SHALL
1/8" = 1'-0" PPC01CARTRIDGES,
` ������ METAL DECK
12
M0UNTING HEIGHT SCHEDULE
—4"
P4
FURNISH AND INSTALL A WATTS LFMMV- MIXING VALVE TO SERVE THE FAUCETS (SET TO 110 F).
CALL
DRAIN
MOEN "52660, OFFSET CHROME PLATED TAILPIECE,
HOT WATER COLD WATER
P2 OUT oo
P2
P47
P1
EXPANSION TANK —
o�
P-3 SERVICE SINK
FIAT #MSB-2424 OR MUSTEE #63
ACUUM RELIEF VALVE
V I
SUPPORT N
SHALL BE LOCATED ON ACCORDANCE WITH
„ CHECK
INSTALL 1.5 SQUARE
GCO
THE COLD WATER INLET CODE.
� VALVE DRAIN
FAUCET
MOEN �8124
ATERILSOLATHEATER
IIEH
UNISTRUT BETWEEN
P2
P1
NTO O
IONS
BETWEEN IT AND THE HOT T & P VALVE
JOISTS AND CLAMP ROUTE K
MOP SINK.
1 —11
P2 o
HWD �
—
P 4 WATER FOUNTAIN
W
HANDICAP ACCESSIBLE DUAL HEIGHT: ELKAY EZTL-8C OR HALSEY TAYLOR HTV8BL-Q
WATER STORAGE TANK. WATER T & P DRAIN
HEATER
PIPE TO UNISTRUT.
INSURE THE HYDRANT
a
-
HEAT TRAP PIPE FULL SIZE TO
MOP SINK.
PIPING IS VERTICAL
AND WELL ANCHORED 3/4" WATER LINE
TERMINATE 2"
DW =DOMESTIC WATER
DRAIN PAN ABOVE FLOOD RIMOF
SINK.
DHW = DOMESTIC HOT WATER P2
PAN DRAIN
3/16" = 1'-0" PPP01R
3/16" = 1'-0" PPP02R
MOP SINK
1 1/2" = 1'-0" PPSO4
1/8" = 1'-0"
PPCO2
9
RESTROOM SEWER PLAN
110JRESTROOV
WATER PLAN
11
PLUMBING FIXTURE SCHEDULE
13
WATER HEATER INSTALLATION
14
ROOF HYDRANT
U)
J
Ln
Q0
Q
W
0
W
N
o
O
I
z
z
O
I
W
O
U-)o
w
'J
0
W
U
U)
w
0)
C
X
LL
LL
\
ti
z
cM
Q
O
Z
=
L_ � W
CD
� �
Z
� Z
W
Cm
G
O Z
OCV 1171yo
O
000
Q d' L.L
d- cio
0O o
U 00
00
c
Ln
ct
4-1 O
U
ct
Q
o�losl ��
�o ••�GENS.
35785 IK
STAT OF
OR
05/28/2021
57N—REMODEL