Loading...
HomeMy WebLinkAboutBuilding PlansDESIGN BASIS: ) CODE: 2017 FLORIDA BUILDING CODE 2) EXPOSURE C, RISK CATEGORY 1 3) V (ALT)DESIGN WIND SPEED 160 MPH, OPEN Pnet = -50 PSF 4) UNIFORM LIVE LOAD = +/-40 PSF, DEAD = +10PSF, POINT LOAD 300# 5) THE PURPOSE OF THESE SPECIFICATIONS IS TO DEFINE UNIFORM CONSTRUCTION STANDARDS IN TERMS OF BOTH GEOMETRY (LENGTH, WIDTH, AND HEIGHT) AND CONSTRUCTION PRACTICE (MATERIALS USED AND HOW THEY ARE INSTALLED). a) PILINGS: 8" PT 2.5 CCA MIN. BUTT DIA. MINIMUM 6' INTO FIRM MATERIAL b) CROSSTIES: EXTENDED 3" BEYOND PILE CENTERLINE, NOT TO PROJECT BEYOND EXPOSED EDGE OF PILE, 2X8 SYP 40 AC PT, s" 304 SS BOLT OR ALL THREAD TO PILE c) STRINGERS: STRINGERS (MAX 18" OF), 2 INTERMEDIATE STRINGERS REQUIRED. EXTERIOR EDGE OF PILING SHALL BE A MINIMUM OF 2" OUTSIDE ANY CROSSTIE, STRINGER, OR DECK BOARD. EXTERIOR STRINGER BOLT TO PILE AS CROSSTIES, 2X8 SYP 40 ACQ PT d) DECK: INSTALL WITH 4" PLANK SPACING USING #10 SS (304) SCREWS, 2 PER DECK/STRINGER INTERSECTION. 2X8 DECK PLANK #1 GRADE 40 ACQ PT. 6) CENTER STRINGERS TO NAILED WITH (2) #16 SS RING SHANK NAILS AT EACH BENT INTERSECTION. OUTSIDE STRINGERS FACE NAILED FOR FLUSH APPEARANCE AND ALIGNED WITH EDGE FASTENING OF DECK NOT TO EXCEED 18" CENTER TO CENTER PROJECT INFORMATION: P.I.: 4502-501-0204-000-1 LEGAL: NETTLES ISLAND INC, A CONDO -SECTION II PARCEL 18 AND PRO-RATA SHARE IN COMMON ELEMENTS (OR 1060-1983) ...................... G/,DENS\; / ` s ? r� THE DOCK DESIGNS SHOWN EXCEED CURRENT INDUSTRY <3ass NO.STANDARDS • FOR DOCK CONSTRUCTION. USE OF THESE �io,e�,� (Q„L.tiI DRAWINGS AND DESIGNS IS AT THE OWNER'S RISK. EVERY 1 i�rov:aa 20�20"7 - EFFORT HAS BEEN MADE TO DESIGN A STRUCTURE THAT 'I o STNTEOF �� ? COMPLIES WITH THE DESIGN CRITERIA. THE DESIGN CRITERIA \ '••,Fs�:�=�i/� IS CONSTRUED TO BE A WARRANTY OR GUARANTEE OF KIND OR TO ANY ENTITYT ANY. MARLAND CONSTRUCTION PO BOX 1138 PORT SALERNO, FL 34992 CBC 1253377 �n � c 0 M r M '4 M ®-®� 0 n nm�m9� 0 0 .fie 0) . -n 0 -0� � � �' �n m CONTRACTOR NOTES BECKER REALTY INVESTMENT 18 NETTLES BLVD. JENSEN BEACH, FL 34957 P.I .: 4502-501-0204-000-1 S.--" -B ... E �\ 6,,,'' / GG N o / � s e �\F ,'. O\ STATE OF SSI ONAI 0� I I ........ THE DOCK DESIGNS SHOWN EXCEED CURRENT INDUSTRY / STANDARDS FOR DOCK CONSTRUCTION. USE OF THESE I DRAWINGS AND DESIGNS IS AT THE OWNER'S RISK. EVERY EFFORT HAS BEEN MADE TO DESIGN A STRUCTURE THAT COMPLIES WITH THE DESIGN CRITERIA. THE DESIGN CRITERIA / IS NOT CONSTRUED TO BE A WARRANTY OR GUARANTEE OF ANY KIND OR TO ANY ENTITY. LOT 19 BECKER REALTY LOT 17 / INVESTMENT / / LOT 18 / (SHORELINE LENGTH 35+/-)------------------------ ------ ------�------- Exisnu NcsEnwn ----------------- r 3' 3' e PROPOSED 29'X10' 030 ®r 0 9m DOCK 00r ® — — — WWTS-EFAQUATIC-Gs VIE* - • — • — • j REQUIRED RETRACTABLE Z Z I I MANMADE CANAL I LADDER (PER 0 WATERBODY WIDTH 47'+/- POAUCE -� NTRA TOR INFORMATION: SITE PLAN PROJECT INFORMATION: MARLAND CONSTRUCTION BECKER REALTY INVESTMENT PO BOX 1138 18 NETTLES BLVD. PORT SALERNO, FL 34992 JENSEN BEACH, FL 34957 CBC 1253377 N.T.S P.I.: 4502-501-0204-000-1 772-223-0105 OFFICE