Loading...
HomeMy WebLinkAboutPlan ReviewSAINT LUCIE COUNTY FIRE DISTRICT PLAN REVIEW FORM 5160 N.W. Milner Drive g Port Saint Lucie, FL 34983 x X' Telephone: 772-621-3322 DIS�� Fax: 772-621-3604 Web Address: www.slcfd.com Building Dept. Saint Lucie County FMO Permit # B-1`2-249 Project Name Outreach Training Center BLDG Permit # 1209-0193 Y Address 8645 South US Highway 1 City Port Saint Lucie Contractor Concordia General Contractor, LLC i Address 5662 SE Schooner Oaks Way City Stuart State Florida Zip 34997 Telephone 954.328.4735 Architect/Engineer Dan Stuart Davis Telephone 772.343.0340 Occupancy Type Business - Instructional — Construction Type 5A Square Feet 1440 Occupant Load 21 Number of Stories Access Box I Access Key Switch AFS Permit FA Permit �— FFP Permit Required General Notes 1. An electronic copy of the construction documents submitted on a CD is required. The file format shall be .pdf only. 2. All revisions, including the electronic copy must be received prior to permitting. 3. The Fire Marshal requires 24 hour notice on all inspections. 4. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. S. Failed inspections require payment of fee prior to rescheduling of further inspections. 6. Penetrations through rated assemblies shall be of the proper UL design. Design criteria shall be submitted with the construction plans. 7. Fire alarm panels shall be located indoors within air conditioned space. S. Plans and construction are subject to corrections in the field to maintain code compliance. 9. Automatic fan shutdown is required for HVAC system/s that exceed 2,000 cfm design capacity. 10. The Installation or Alteration of Fire Sprinklers, Fire Alarms, and Fixed Fire Protection Systems require a separate review and permit. THE FLORIDA FIRE PREVENTION CODE, 2010 EDITION IS CURRENTLY ENFORCED. BUILDINGS WITH LIGHT -FRAME TRUSS -TYPE CONSTRUCTION SHALL BE MARKED WITH APPROVED FIREFIGHTER SAFETY WARNING SIGNS IN ACCORDANCE WITH FLORIDA ADMINISTRATIVE CODES 69A-3.012 AND 69A-60.0081 PRIOR TO RECEIVING A CERTIFICATE OF OCCUPANCY. See General Notes Above and Required Revisions Below 1. Protection of the cooking equipment shall be required if cooking will take place within this facility. 2. Provide portable fire protection accordingly. Page 11 1 of 1 Reviewed by T. Liento Date 11-07-2012 DAN STUART DAVIS ® AM 7410 S. US-1, #310, Port St. Lucie, FL 34952 772-979-3380 AN&, October 22, 2012 FILE CU Py Building Department, Plan Review St. Lucie County Florida RE: 1209-0193, OUTREACH TRAINING CENTER, 8546 S. US-1, PSL Plan Reviewer The following items respond to each Review Comment listed on your summary of October 11, 2012 and are illustrated by the clouded revisions delta-1, dated 10/12/12, on the attached drawings and on the accompanying compact disc for Fire Dept. as follows: MECHANICAL: PETERSON — 1015/12 #1 — MECHANICAL SCOPE: See HVAC Notes and at Ceiling Plan on sheet 2. @UILDING: CICIO — 10111112 #1 — CODE DATA: See sheet 1 for revised data. #2 — LIFE SAFETY PLAN: Occupant load and travel distances are shown on Floor Plan sheet 1. #3 — SIGN CHANGES- Will be applied for separately. PLUMBING: SMYTH — 1015112 #1 — HI-LO DRIWNG FOUNTAIN: See Floor Plan & Enlarged Plumbing Plan for accessible fountain. I trust this addresses your comments completely. Please call if you have any questions. Sincerely, rn Dan S. Davis, Architect DAN STUART DAVIS — AIA FL AR 17155 OCT 2 a 2012 Public Works St. Lucie County, FL