HomeMy WebLinkAboutlot79 blower door testma
Duct Leakage Test Report
Prescriptive or Performance Method
Permit #
Job Information
Builder: DR HORTON Community: f, Lot: 71)
Address: 333 i Unit: Ca/,'
City: 1=c-f 4r State: FL Zip: 3y ys—"
Duct Leakage Test Results O Presciptive Method 0 Performance Method
System 3
of any additional
of all systems
50 - a/cd 8 = 0.03 Qn
Total of all systems
C_�A ss
Total Conditioned
Square Footage
[] FAIL
) Prescriptive Method cfm25 (total)
3 qualify as "substantially leak free" On must be less than or equal to 0.04
air handler unit is installed. If air handler unit is not installed, Qn Total
ust be less than or equal to 0.03, This testing method meets the
,quirements in accordance with Section R403.2.2
Performance Method cfm25 (Out or Total)
To qualify as "substantially leak free" Qn must not be greater than the
proposed duct leakage Qn specified on Form R405-2014
Leakage Type selected
on Form R405-2014
(Energy Caic)
Qn specified on Form
R405-2014 (Energy Calc)
Testing Company
Company Name: SUN SEAL LLC Phone: 321-412-0035
1 hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: s3 ) t L i 1V a, i
Signature of Tester:
Printed Name of Tester: RAULY BAGGETT
License/Certification # 5066185 Issuing Authority BPI
Envelope Leakage Test Report
(Blower Door Test)
R402.4.1.2 Compliance
Permit #
Job Information
Builder: DR HORTON Community: ceee,t�s,' a Lot:
Address: 3.333 + C Unit:
City: rY /> a rc State: FL Zip: 3ygy�
Air Leakage Test Results Passing results must be 7 ACH(50) or less
/ / x 60 _ 157�0 = / Method for calculating building volume:
CFM(50) Building Volume ACH(50) O Retrieved from architectural plans
Q Code software calculated
E�'PASS FAIL
O Field measured and calculated
When ACH(50) is less than 3, Mechanical Ventilation installation must be verified by building department.
Certification of Test Results
��......�... ,Doug. 1 nc VUIW lllg 111 uwmirtg unu sndu be tested and vermea as raving an au leakage rate of not exceeding 7 air changes
per hour in Climate Zones 1 and 2, 3 air changes per hour in Climate Zones 3 through 8. Testing shall be conducted with a blower door at
a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by wither individuals as defined in Section 553.993(5) or (7), F.S. or
individuals licensed as set forth in Section 489.105(3)(f), (g), or (1) or an approved third party. A written report of the results of the test
shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of
Testing Company
Company Name: SUN SEAL LLC Phone: 321-412-0035
1 hereby verify that the above duct leakage testing results are in accordance with the Florida Building Code requirements with the selected
compliance path as stated above, either the Prescriptive Method or Performance Method.
Date of Test: A i I . 12L. )'(
Signature of Tester: (Zad w 61,5 el
Printed Name of Tester: RAULY BAGGETT
License/Certification # 5066185 Issuing Authority BPI