HomeMy WebLinkAboutReview CommentsPlanning & Development Services
BuildingA Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. -34982
Phone:_(772)462.2172 Fax:(772)462-6443
PROPERTY INFORMATION
Address: 8641 - 8643 S Us Highway 1
City / State / Zip: Port Si. Lucie, FI- 34952
Parcel #: `3414=501-1912-500/6
Zoning: CG
APPLICATION INFORMATION
Permit Number: 1901-0297
Permit Type: COMMERCIAL RENOVATION
REVIEW COMMENTS
Owner(s):
Crowne St Lucie Associates Lp
Jurisdiction: SAINT LUCIE COUNTY
Lot#: 12 Block: 3
Stories:
CONTRACTOR INFORMATION
Contractor Name: Roderick J Waller
Business Name: Sunrise City Community Housing Dev Org Inc
Business Addr: 130 S Indian River Drive Suite 202
City I State I Zip: Fort Pierce, FI 34950
REVIEWS AND COMMENTS
1
Automatic Sprinkler System? No
Fax Number: 772-907-0420
Review Type
Status
Reviewed By Date Started
DOCUMENTS MISSING
PENDING
Audrey Humphrey 1/16/2019
•111612019 Comment:
NEEDS A RECORDED NOTICE OF COMMENCEMENT
1/16/2019 Comment:
NEEDS AN ELECTRICAL AND PLUMBING SUB AGREEMENT.
FIRE DEPARTMENT REVIEW
INCOMPLETE
Tony Jerger
Comment:
FRONT COUNTER REVIEW
COMPLETE
Audrey Humphrey 1/16/2019
Comment:
PE REVIEW COMMENTS (2)
INCOMPLETE
William Durden 5/21/2019
Comment:
Email: Rodwallerl@Gmail.Com
Date Completed Date Released
i
1/16/2019 1/16/2019
'611412019 6/14/2019
PE REVIEW COMMENTS (3) INCOMPLETE William Durden 6/14/2019
Comment: PLANS WERE REVISED TO SHOW A3 OCCUPANCY AND OCCUPANT LOAD OF 247. PER TABLE 2902.1 AN
ADDITIONAL WATER CLOSET IS REQUIRED FOR THE FEMALE RESTROOM. PLEASE SUBMIT REVISED
PLANS.
5/21/2019 REVISED PLANS SHOW ON PAGE A-5 A REFERENCE TO A B-OCCUPANCY, THE NEW SPACE WILL BE AN A-3
OCCUPANCY. PLEASE CORRECT.
PLEASE SHOW ON THE PLANS THE OCCUPANCY AND OCCUPANCY LOAD, IN COMPLIANCE WITH SECTION
302 AND 1004 OF THE 2017 FLORIDA BUILDING CODE.
Comment: NO MANUAL J SUBMITTED FOR REVIEW. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE.
5/21/2019 PLEASE SUBMIT A MANUAL J TO CLARIFY IF THE UNIT SIZING IS ADEQUATE FOR THE USE. SEE SECTION
107 OF THE 2017 FLORIDA BUILDING CODE.
;4
Planning & Development Services
Building A Code Regulation `Division.
2300 Virginia Avenue
FortPierce', FL. '34982
Phone:(772)462-2172 Fax:(772)462-6443
REVIEW COMMENTS
U
5/21/2019 comment: NLEASE SUBMIT A REVISED C/D FOR FIRE REVIEW.
Comment: NO DETAILS SHOWN FOR THE EXISTING FIRE SPRINKLER SYSTEM OR THE RELOCATION OF EXISTING
SPRINKLER HEADS FOR THE NEW RESTROOM AREA. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING
5/21/2019 CODE.
PLEASE SHOW ON THE FLOOR PLAN THE EXISTING FIRE SYSTEM LOCATIONS. SEE SECTION 107 OF THE
2017 FLORIDA BUILDING CODE,
PLANS EXAMINER ELECTRIC
COMPLETE Walter Pride 5/21/2019 512212019. 5/22/2019
Comment:
PLANS EXAMINER MECHANICAL
INCOMPLETE Gary Stepalavich 6/14/2019
5/21/2019 Comment:
PLEASE ADD TO THE PLANS MECHANICAL VENTILATION MEETING THE REQUIREMENTS OF TABLE
403.3.2.3 OF THE 2017 MECHANICAL BUILDING CODE.
Comment:
6/14/19. STILL NEED MECHANICAL PLANS THAT ARE COMPLIANT WITH THE FLORIDA BUILDING CODE.
6/14/2019
PLEASE REFER TO THE FLORIDA BUILDING CODE SECTION 107.3.5 "MINIMUM PLAN REVIEW CRITERIA FOR
BUILDINGS" - MECHANICAL.
PLANS EXAMINER PLUMBING
COMPLETE Andy Wentz 6/14/2019 6/14/2019 6/14/2019
Comment:
PLANS EXAMINER PLUMBING INCOMPLETE Andy Wentz 6/14/2019
6/14/2019 Comment: NEED 2 WOMEN'S WATER CLOSETS PER TABLE 403.1 FLORIDA PLUMBING CODE 2017 6TH EDITION PER
THE OCCUPANCY AND CLASSIFICATION
PLANS EXAMINER REVIEW COMPLETE William Durden 1/22/2019 3/12/2019 3/12/2019
Comment:
PLANS EXAMINER REVIEW COMPLETE William Durden 3/14/2019 5/21/2019 5/21/2019
Comment:
ZONING REVIEW
INCOMPLETE Lydia Galbraith 1/17/2019
1/17/2019
Comment: ADDRESS ON APPLICATION IS INCORRECT. ACCORDING TO OUR RECORDS THIS TENANT IS GOING TO
OCCUPY UNIT 8641 - 8643. APPLICATION WILL NEED TO BE CORRECTED.
1/17/2019
Comment: THE BUILDING PLANS INDICATE THE RENOVATION TO BE FOR GENESIS COMMUNITY CHURCH. PLANS
WILL NEED TO INDICATE THE CORRECT TENANT NAME.
Comment: ACCORDING TO OUR INFORMATION THE TENANT IS ONLY GOING TO USE TWO UNITS. THE DOORS
1/17/2019
BETWEEN 8641 -'8643 AND 8637 - 8639 WILL NEED TO BE CLOSED OFF. THIS RENOVATION CAN BE
INCLUDED UNDER THIS PERMIT AND WILL NEED TO BE ADDED TO THE BUILDING PLANS. (INDICATE THE
COMPLETE UNIT ON THE PLANS)
Comment: PLEASE BE AWARE THAT ABOVE COMMENTS ONLY REFLECTS THE ZONING REVIEW. THE PLANS
1/17/2019
EXAMINER MIGHT HAVE ADDITIONAL COMMENTS. WE WOULD LIKE TO SUGGEST TO WAIT WITH
CORRECTIONS UNTIL THE PLANS EXAMINER HAS COMPLETED HIS REVIEW AS WELL.