Loading...
HomeMy WebLinkAboutSewage�>\ M t-'o C:21 01-0 (Cl I STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM �F mn PERMIT #:56-SF-2220145 APPLICATION #: AP1612193 DATE PAID: FEE PAID: t� IPT #: 0 NT #: PR1524584 APR 1 '3 2021 CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: (Beltran Construction) n,. PROPERTY ADDRESS: 5722 Papaya Dr Fort Pierce, FL 349 , LOT: 14 BLOCK: 79 SUBDIVISION: Indian River Estates K3 PROPERTY ID #: 3402-610-0279-000-2 f�l[sEc'CN,OWNSHIP�—RP�NGfE.,,PARCEyLNUMBER] [ORF,TAX-IDhh�N[7MBETt� l it".1 SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 381.0065, F.S., AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS T [ 900 ] GALLONS / GPD Septic new CAPACITY A [ ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] K [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #Pumps [ 7 D [ 334 ] SQUARE FEET "aff fe GT�1, a SYSTEM R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [X] MOUND I CONFIGURATION: [ ] TRENCH [X] BED [ ] N F LOCATION OF BENCHMARK: -i% raHgelpgt.Glt X44ift hiRdingant rlt I ELEVATION OF PROPOSED SYSTEM SITE E BOTTOM OF DRAINFIELD TO BE L D B 0 T H E R [ 4.00 ] [INCHES FT I[ BELOW ]BENCHMARK/REFERENCE POINT [ 3 0 [INCHES F ] ABOVE,,BELOW]BENCHMARK/REFERENCE POINT ;u_ .. REQUIRED: [YU.UU] INCHES EXCAVATION REQUIRED: [ SG.UUJ INCHES system is sized for 2 bedrooms with a maximum occupancy of 4 persons (2 per bedroom), for a total estimated flow of 9pd• SPECIFICATIONS BY: Brian J Ingram TITLE: Environmental Specialist III APPROVED BY: TITLE: Environmental Specialist III St. Lucie CHD Brian J Wam DATE ISSUED: 03/31/202q EXPIRATION DATE: DH 4616, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC v 1.1.4 AP1612193 szl491996 09/30/2022 Page 1 of 3 NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a 'final order. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. St. Lucie County Health Department HEALTH 5150 NW Milner Dr Port Saint Lucie, FL 34983 PAYING ON: #: 56-SF-2220145 BILL Doc #:56-BID-5150700 CONSTRUCTION APPLICATION #: AP1612193 RECEIVED FROM: Alexander J Piazza PSM Inc. AMOUNT PAID: $ 545.00 PAYMENT FORM: CHECK 023 PAYMENT DATE: 01/11/2021 MAIL TO: (Beltran Construction ) FACILITY NAME: PROPERTY LOCATION: 5722 Papaya Dr Fort Pierce, FL 34982 14 Lot: 79 Block: Property ID: 3402-610-0279-000-2 EXPLANATION or DESCRIPTION: QUANTITY FEE 128 - OSTDS Construction System Inspection Research Fee 1 $ 5.00 -1 - Surcharge (All) 1 $ 45.00 -1 - OSTDS New Permit Surcharge 1 $ 100.00 -1 - OSTDS Construction Application and Plan Review,New 1 $ 100.00 123 - OSTDS Construction Site Evaluation 1 $ 115.00 126 - OSTDS Construction Permit (New or Mod, Amendment) 1 $ 55.00 127 - OSTDS Construction System Inspection 1 $ 75.00 133 - OSTDS Construction Reinspection 1 $ 50.00 RECEIVED BY: AdamsC AUDIT CONTROL NO. 56-PID-4854632 ({LE STATE OF FLORIDA -) DEPARTMENT OF HEALTH yrf° ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM wee APPLICATION FOR CONSTRUCTION PERMIT APPLICATION FOR: PERMIT NO. 1 DATE PAID: C,j FEE PAID: 1! � E; IT-.4 5 RECEIPT #: [✓] New System [ ] Existing System [ ] Holding Tank [ ] Innovative [ ] Repair [ ] Abandonment [ ] Temporary' [ ] APPLICANT: BELTRAN CONSTRUCION, INC. 1 AGENT: Alexander J. Piazza PSM, Inc. TELEPHONE: 772-340-7770 MAILING ADDRESS: 619 SW Biltmore Street, Port St. Lucie, Florida 34983 TO BE 'COMPLETED BY APPLICANT OR APPLICANT'S AUTHORIZEM RAGENT . SYSTE&MIS MUST BE CONSTRUCTED BY A PERSON LICENSED PURSUANT TO 489.105(3)(m) OR 489.552, FLORIDA STATUTES. IT IS THE APPLICANT'S RESPONSIBILITY TO PROVIDE DOCUMENTATION OF THE DATE THE LOT WAS CREATED OR PLATTED (MM/DD/YY) IF REQUESTING CONSIDERATION OF STATUTORY GRANDFATHER PROVISIONS. PROPERTY INFORMATION LOT: 14 BLOCK: 79 SUBDIVISION: INDIAN RIVER ESTATES UNIT 9 PLATTED: 1956 PROPERTY ID # PROPERTY SIZE: 0.23 3402-610-0279-000-2 ZONING: R I/M OR EQUIVALENT: [ No ] ACRES WATER SUPPLY: F./1 PRIVATE PUBLIC rv42000GPD [ 1>2000GPD IS SEWER AVAILABLE AS PER 381.0065, FS? [ No ] DISTANCE TO SEWER: FT PROPERTY ADDRESS: 5722 PAPAYA DRIVE, FORT PIERCE, FLORIDA 34982 DIRECTIONS TO PROPERTY: SEE MAP BUILDING INFORMATION [✓1 RESIDENTIAL [ ] COMMERCIAL Unit Type of No Establishment 1 RESIDENCE 2 3 4 No. of Building Commercial/Institutional System Design Bedrooms Area Sqft Table 1, Chapter 64E-6, FAC 2 1,056 [ 1 Fl0or/EquiptuenL Drain6 [ ✓ 1 Other (Specify) aAPRACyF CMTNTIFPC /MRPORAT.0 Alexander J Piazza nn us. u„im;,Mou-nuiaiuouoomi�+��u43ma�mm�m-,u�c �r SIGNATURE: WW. 11-15-20 ��: ��:,A� �.�� ���;�w� �,>>�„• DATE DH 4015, 08/09 (Obsoletes previous editions which may not be used) incorporated 64E-6.001, FAA rage i o= 4 STATE OF FLORIDA DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATION APPLICANT: Beltran Construction CONTRACTOR / AGENT: Alexander J Piazza PSM Inc. LOT: 14 BLOCK: 79 SUBDIVISION: Indian River Estates ID#: 3402-610-0279-000-2 APPLICATION # AP1612193 PERMIT # 56-SF-2220145 DOCUMENT # SF1491998 TO BE COMPLETED BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE, OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [X]YES [ ]NO NET USABLE AREA AVAILABLE: 0.23 ACRES TOTAL ESTIMATED SEWAGE FLOW: 200 GALLONS PER DAY [-RESIDENCES-TABLET / OTHER -TABLE 2 ] AUTHORIZED SEWAGE FLOW: 575.01 GALLONS PER DAY [ 1500 GPD/ACRE OR 1 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 1000.00 SQFT UNOBSTRUCTED AREA REQUIRED: 500.00 SQFT BENCHMARK/REFERENCE POINT LOCATION: Site BM, orange paint "X", CL of Rd near center of ELEVATION OF PROPOSED SYSTEM SITE 4.00 [IINCHESI/ FT ] [I ABOVE I/ BELOW ] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER: FT DITCHES/SWALES: 35 FT NORMALLY WET: [ ]YES [XINO WELLS: PUBLIC: FT LIMITED USE: FT PRIVATE: FT NON -POTABLE: 50 FT BUILDING FOUNDATIONS: 5 FT PROPERTY LINES: 5 FT POTABLE WATER LINES: 16 FT SITE SUBJECT TO FREQUENT FLOODING? [ ]YES EX ]NO 10 YEAR FLOODING? [ ]YES [X]NO] 10 YEAR FLOOD ELEVATION FOR SITE: FT [ MSL / NGVD ] SITE ELEVATION: FT [ MSL / NGVD Rr1TT. ARnVTT.F. TNFARMATTAN RTT7. 1 CATT. DRAWTT.W. TNWARMnTTAN CTTW. 9 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 411 Sand 0 TO 5 1 OYR 5/2 Sand 5 To 36 10YR 6/1 Sand 22 To 30 10YR 2/1 Spodic Material 36 To 39 1 OYR 4/1 Sand 39 To 45 10YR 2/2 Spodic Material 45 To 52 1 OYR 4/4 Fine Sand 52 To 72 USDA SOIL SERIES: Munsell #/Color Texture Depth 10YR 4/2 Sand 0 To 7 10YR 5/1 Sand 7 To 29 10YR 6/1 Sand 24 To 31 1 OYR 2/2 Spodic Material 31 To 46 10YR 4/3 Fine Sand 46 To 72 OBSERVED WATER TABLE: 59.00 INCHES [ ABOVE / BELOW ] EXISTING GRADE TYPE: ( PERCHED / APPARENT ] ESTIMATED WET SEASON WATER TABLE ELEVATION: 22 INCHES [ ABOVE / BELOW ] EXISTING GRADE HIGH WATER TABLE VEGETATION: EX ]YES [ ]NO MOTTLING: [X]YES [ ]NO DEPTH: 22.00 INCHES SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: Sand/0.60 DEPTH OF EXCAVATION: 52 INCHES DRAINFIELD CONFIGURATION: [ ] TRENCH [XI BED [ ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA WSWT determined using USDA WSS and soil borings. 10YR6/1 stripping in 10YR5/2 matrix.> 10% with diffuse boundaries starting at 22" in SB1. SB1 4" above BM. SB2 6" above M. SITE EVALUATED BY: DATE: 03/19/2021 Ingram, B n (Title: Environmental Specialist III) (ENVIRONMENTAL HEALTH) DH 4015, 08/09 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 Of 4 AP1612193 EID2220145 v 1.0.2 E 'TH STATE OF FLORIDA PERMIT # . DEPARTMENT OF HEALTH ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM SITE EVALUATION AND SYSTEM SPECIFICATIONS .E APPLICANT: BELTRAN CONSTRUCION, INC. AGENT : Alexander J. Piazza PSM, Inc. LOT: 14 BLOCK: 79 SUBDIVISION: INDIAN RIVER ESTATES UNIT 9 PROPERTY ID # : 3402-610-0279-000-2 [ Tax TD Number ] TO BE COMPLETED' -BY ENGINEER, HEALTH DEPARTMENT EMPLOYEE,OR OTHER QUALIFIED PERSON. ENGINEERS MUST PROVIDE REGISTRATION NUMBER AND SIGN AND SEAL EACH PAGE OF SUBMITTAL. COMPLETE ALL ITEMS. PROPERTY SIZE CONFORMS TO SITE PLAN: [✓] YES [ ] NO NET USABLE AREA AVAILABLE: 0.23 ACRES TOTAL ESTIMATED SEWAGE FLOW: 333 GALLONS PER DAY [RESIDENCES -TABLE VOTHER-TABLE 2 ] AUTHORIZED SEWAGE FLOW: GALLONS PER DAY [ 1500 GPD/ACRE OR 2500 GPD/ACRE ] UNOBSTRUCTED AREA AVAILABLE: 500 SQFT UNOBSTRUCTED AREA REQUIRED: 500 SQFT BENCHMARK/REFERENCE POINT LOCATION: ELEVATION OF PROPOSED SYSTEM SITE IS34 [INCHES/ET ] [ABOVE/BELOW] BENCHMARK/REFERENCE POINT THE MINIMUM SETBACK WHICH CAN BE MAINTAINED FROM THE PROPOSED SYSTEM TO THE FOLLOWING FEATURES SURFACE WATER:100 FT DITCHES/SWALES:15 FT NORMALLY WET? [ I YES [✓] NO WELLS: PUBLIC:200 FT LIMITED USE:100 FT PRIVATE:75 FT NON-POTABLE:100 FT BUILDING FOUNDATIONS:5 FT PROPERTY LINES:10 FT POTABLE WATER LINES: FT SITE SUBJECT TO FREQUENT FLOODING: [ ] YES [VI NO 10 YEAR FLOODING? ] ] YES [✓] NO 10 iEAR FLOOD ELEVATION FOR SITE: FT M.7L/lVliV1J SITE ELEVATION: FT MSL/NG'V1J SOIL PROFILE INFORMATION SITE 1 MUNSELL #/COLOR USDA SOIL SERIES: TEXTURE DEPTH TO mn iV mn TO TO TO TO TO mn OBSERVED WATER TABLE:40+ INCHES [BELOW ESTIMATED WET SEASON WATER TABLE ELEVATION: LTSLi vu iiniur TaT-auiiati'a vL�sz'.Ts�aT ivii: L I a=..7 L ] SOIL PROFILE INFORMATION SITE 2 MUNSELL #/COLOR TEXTURE DEPTH TO mn iv TO TO TO TO TO TO TO USDA SOIL SERIES: ] EXISTING GRADE. TYPE: [PERCHED/ APPARENT I _ INCHES [.ABOVE/BELOW ] EXISTING GRADE 7jr^ MT TTTo�. 1 \7L1C 1 RT/1 TLaTTV T%T/'�LTLTC L•1VSiLit\l7. ( f iJ:saa J L\V LJJ�t 111. 1L\VLLEV SOIL TEXTURE/LOADING RATE FOR SYSTEM SIZING: DEPTH OF EXCAVATION: INCHES DRAINFIELD CONFIGURATION: [✓] TRENCH [ BED ( ] OTHER (SPECIFY) REMARKS/ADDITIONAL CRITERIA: A A i EIS I.,-...�� nvy-i ie y��q�,ryip.�.a ��c� en e�M.mm7�:�rncnarnn�i7pe. hkfXaliuet i riazza c Aieaande,l Pis SITE EVALUATED BY: oateN20.11.I510AU3.05•00' DATE: 11-15-20 DR 4015, 12/11 (Obsoletes previous editions which may not be used) Incorporated: 64E-6.001, FAC Page 3 Of APPLICANT'S NAME: BELTRAN CONSTRUCION, INC. LEGAL DESCRIPTION: LOT 14, BLOCK 79, INDIAN ROVER ESTATES UNIT 9 (PB 10,PG 7z r Px. =ns� rr�l n c�; Tn F, �. crV � '?F t"7F'7 r.v.. r .) xT'1�r�di �`1(�11I t•kzv COUl ll La1:1;! -:L%-, 1T.A.u..a_jXr-e. isrs-x r1, U.-IUK" 24,tvim, r T certify that there are no potable private wells within 75 feet of the available area for the proposed septic system, that there are no non -potable wells within 50 feet of the available area for the proposed septic system, that there are no wells within 25 feet of a pesticide -treated 1. 414; n• -Pr. 1rAl +t-r +l�n - tl-lara ara nn "17blir -11S that Centre lace than 25 npnnle or leg.g tf 2n U Ulllllll� 1Vt111l1CLLl Vll, L114L ".0,1 �+ uiv Xiv ruviiv vv 1+-�1-- 15 homes or businesses within 100 feet of the proposed septic system, that there are no public wells that serve more than 25 people or more than 15 homes or businesses within 200 feet of the proposed septic system, LnaL the Water 1111C ILU111 L11C Water i11GLGi V1 well Lv t hiv s LL U10 is at least 10 _feet from the available area for the proposed septic system unless the plans show the line to. be double sleeved, that there is not a gravity sewer line, low pressure sewer line or vacuum sewage line in a public easement or right-of=way that abuts the property, that there are no1 7 +,-onwrin .a+ln»rlo nr enrfara sxratar rxlitli;n "IS fppt of the a'vnilalile area fnr tile. 1Q111rJ, O L1 V CL111J, VV V L1CL11-LLJ, vi V ul tuvv 11 l t_. a riiv..a r �. _ proposed septic system unless the property was created prior to 1972, that the septic system is proposed on the side of the lot farthest from surface water, that all private wells, septic systems and surface water on adjacent or couLiguous land w1u-1111 75 UM of LUG appl'1Ca.11L'0 WL are. shown on- the site plan., that all public wells within 200 feet of the applicant's lot are shown on the site plan, and that the location of building or residences, swimming pools, recorded easements, paved areas or driveways, sidewalks, the general slope of file property, -C11-A n.-one+ rlrni"nrra 4:'an+Tlrae a,A gnrfarp -wifPrs sl`TC11 as 1�lllP.0 nonci gfrenm.-,� (-.ai'15_ .-, or 11111+U Ql IJUJ, ♦ r s U111Qb1, 1V C1Lu1 lrJ, ta..ttu V tA11µV v , t. —�V, — wetlands are shown on the applicants lot. The natural grade elevadoI1 In file area of tile.proposed Septic Systern and Lhi. benClllllari� rnust he shown on the site flan. Please locate the benchmark within 200 feet of the proposed septic system. NOTE: MUST BE CERTIFIED BY A FLORIDA REGISTERED S U KV C. Y OR OR EN G11,ME ic. Mg i W ly signed by Newnan 1 Ni A 1.. ..I.. 1 1")7.. oN:c=u5.o=unarrumea. Mexal lller i r Iazza °"-ac;:mcasccorsc:::zcawmc;r:, m Aluander)PL .-a CERTIFIED BY: Dak1020.11.1510.48:42-05'00' rr nn Yl A nnr V.T' Lfs CsinTin T t1v.. \T!1 - TI /ZZ P LllLLALK CLtV1'J�JIV L�[-4L DATE: 11/15/20 JOB NO.: 20-6311 aocsi tormsisepcicsiSeplicnpppPage-v7 CS_ IS A2 A3 M1 E1 P1 PROJECT INFORMATION JURISDICTION-- ST. LUCIE COUNTY FLORIDA CLASS.: RESIDENTIAL R-3 TYPE OF CONSTRUCTION -- I — NEW CONSTRUCTION FIRE SPRINKLER SYSTEM --NOT REQUIRED FIRE ALARM --NOT REQUIRED BUILDING CODE: 2020 FLORIDA BUILDING CODE-7th edition ASCE 7-16 EXPOSURE: C BUILDING DESIGNED AS ENCLOSED MEAN ROOF HEIGHT: 14.5 FT IMPORTANCE FACTOR: 1.0 BASIC WIND VELOCITY: 170 MPH, 3 SECOND GUSTS ROOF MATERIAL: METAL ROOF PER PRODUCT APPR. SHEET OVER SHEET IRST FLOOR PLANS XTERIOR ELEVATIONS (FRONT + RIGHT) EXTERIOR ELEVATIONS (REAR ECH AN I CAL PLAN ELECTRICAL PLAN PLUMBING PLAN / RISERS 30 PSF ROOF LIVE LOAD: 25 PSF SOIL BEARING CAPACITY- 2500 PSF ASSUMED REVIEWED FOR SHEAR WALL REQUIREMENTS : YES IMPACT PROTECTION: IMPACT GLASS INTERNAL COEFFIECIENT: 0.18 DESIGN PRESSURES FOR OPENINGS (IN PSF): WITHIN 3FT FROM CORNERS: SEE ELEVATIONS GREATER THAN 3 FT FROM CORNERS: SEE ELEVS. GARAGE DOOR- SEE ELEVATIONS INSULATION. FLOORS: R-13 BATT WALLS CBS: R-4.1 FOIL WALLS WOOD: N/A ROOF: R30 MIN ROOF NAILING PATTERN: 8 D RING SHANK NAILS AT 4" EDGE AND FIELD ROOF SHEATHING: %" EXTERIOR GRADE PLYWOOD W/ RADIANT BARRIER + LEFT) NDEX a S2 &I D1 -FOUNDATION PLAN EAM/COLUMN OOF FRAMING PLAN ETAILS GENERAL CONSTRUCTION NOTES: 1. All construction shall conform to the Florida building code, and all other applicable governing codes and regulations. 2 Contractor shall verify all dimensions and conditions in the field prior to the bidding of the project Any discrepancies which may dtw the intent of the architectural or engineering documents are to be brought to the Immediate attention of the architect in writing, for approval or modification. 3. All work shall be performed in strict accordance with the best practices of the construction trades In a professional and workmanlike manner. Any work not conforming with these standards may be rejected by the architect and redone by the contractor at no additional eNpense to the owner. 4. All materials and labor to have a one yew warranty form dote of completion. 5. All wood members In direct contact with concrete and masonry shag be treated with approved preservative. 6. General contractor shall submit to the Architect shop drawings for review and approval of all specialty items such as cabinetry prior to fabrication. 7. General contractor shall submit approved shop drawings, Engineering data, product approvals and any other required infonnatlon to the Building Department for ON new materials they may require this information for review and approval prior to commencement of construction. d Written Dimensions take precedence over scaled drawings. These drawings are not to be scaled for precise or critical dimensioning. 9. Contractor to use approved survey vs. site plan for precise layout of building and other site improvements. 0 FDOH in St. Lucie County Environmental Health Site Plan ved for Construction Supersedes Ak vious Site Plans for OSTDS & Well # Date: y Zt�?( /J _. - Review6r. ADVANCED DESIGN 8 BUILDING ARCHITECTS GENERAL CONTRACTORS A ROUND HILL DEVELOPMENT GROUP COMPANY 17968 115 TH AVE. NORTH JUPITER, FLORIDA 33478 PH: 561-216-1000 CELL 561-718-0831 319 167TH ST NO. MIAMI BEACH, FL, 33162 305-454-8000 WWW. ADVANCED—DESIGN-BUILDING.COM THESE DRAWINGS AID SPECSCAnONS ARE NSRM.IENTS OF SERVICE AND ARE THE PROPERTY OF ROUND MLL OEVET.oPHmNr OROtW, NC. Mbar ADVANCED OEM ! iWAlAN0. THEY ARE NOT eE USED ON ANY OTHER PRQECiB OR EXTENSIONS OF 'HIS PROJECT EMM" BY WPoNETN ACREENENTS WITH ROUND HILL DEVELOPMEM ORM P. NO OEM CHANCES WHICH ALTER IRE INTENT OF THESE DRAWINGS OR SPEC11CAMIS ARE TO BE MADE WITHOUT OBTAINING WRITTEN PERMISSION FROM ROUND HILL DEVELOPMENT GROUP. ARCHITECT: c-A c-4 � JONES e�ZA�TE t ARCHI C �'`,ERNA14 Ro °� A m, 'q'%0 S GT , 7 DATE CLIENT: SMALL HOUSE PROJECT ■ ADDRESS: COVER SHEET REVISIONS: DRAWN BY: JMG CHECKED BY: BVJ PROJECT # SCALE: } INCH rw'6�'() 0"q MJURISDICTION=-ST. LUCIE COUNTY, FLORIDA OCCUPANCY CLASS-- RESIDENTIAL R-3 TYPE OF CONSTRUCTION --V FIRE SPRINKLER SYSTEM --NOT REQUIRED FIRE ALARM --NOT REQUIRED BUILDING CODE: 2020 FLORIDA BUILDING CODE 7TH EDITION. NATIONAL ELECTRICALCODE 2017 ASIDE 7-16 EXPOSURE: C BUILOING DESIGNED AS ENCLOSED MEAN ROOF HEIGHT: 19 FT IMPORTANCE FACTOR: 1.0 WIND VELOCITYi Vuit-170 Vasd=132 qh=56.57 D Kh=.85 Kzt=1.0 Gcpi-.18+/- GCpf=1.0+, 1.4- P=0.6w ROOF MATERIAL METAL ROOF PER PRODUCT APPROVAL ROOF DEAD LOAD: 30 PSF ROOF LIVE LOAD 25 PSF SOIL BEARING CAPACITY: 2500 PSF REVIEWED FOR SHEAR WALE REQUIREMENTS : YES IMPACT PROTECTION: PER PRODUCT APPROYAL-- WINDOWS AND DOORS IMPACT RATED INTERNAL COEFFIECIENT: 0.18 ffi% CAT GA ORY ". It END ZONE) o1H FOR 3OFT L BUILDING: 3 FT COMPONENTS AND CLADDING DESIGN WIND PRESSURE WALL_ ROOF ZONE LE@ward/WIndward Leeward ndward TRIBUT.AREA 10sf 1 -36.7 +23.1 ROOF PERIMETER 2 -63.8 +23. ROOF CORNER 3 63.8 +23�1 WALL INFIELD 4 -43.4 +40.1 WALL CORNER 5 -53,6 +40.1 DESIGN PRESSURES FOR OPENINGS (IN PSF) SEE WIND DATA ON SHEET D-1 INSULATION: : WALLS R 4.1 MIN OR WALLS R13 ®_ 6" FRAME EXTERIOR ®re ROOF R 30 MIN I ROOF NAILING PATTERN IF REQUIRED 1. 8 D RING SHANK NAILS AT 4' EDGE' AND 4" FIELD WALL SHEATHING : 1.1rEXTERIOR GRADE PLYWOOD W/ BD RING SHANK NAILS 0 2 4" O.C. AND 6" FIELD a WINDOW AND DOOR SCHEDULE NO. NOMINAL SIZE WIDTH X HT. TYPE 10 V-0" WIDE X 8'-0" HIGH MAIN ENTRY DOOR (D T-0"WIDE X V-4" HIGH ALUM. SINGLE HUNG O 60MI)E X 6'8" HIGH SWING DOOR O 4'-TV41DEX3'-7'HIGH TRANSOM (BATHROOM) 1 O 8'-0" WIDE X T-0" NIGH ARCH TOP TWIN WINO ALL DOORS AND WNDOM NOMINALSIZES LISTED -SEE MASONRY OPENINGS ON SHEET 62 AND VERIFY WITH OTHER l VANDOVIREP CONTRACTORTO VERIFY ROUGHOPEMNG CMENSIONS FOR DOORS ANDW1NOOw8 ORDERED Ili PPoORTO CONSTRUCTION ALL DOORSAND WNDONB TO BE LONE GLASS AND IMPACT PER PRODUCT APPROVAL REAR PORCH 9 FT CEILING 9'-0" 5'-6" u O . 0 3 11'-6" 5• O" 12'-0" AS B N BREAKFAST I ` 9 FT 9 FT CLNG CLNG 0 MASTER BEDROOM o RAISED BAR 9 FT CLNG ; r 0 . DW GD I SINK �I 5 -4" 10 ' CL 012 KITCH P LAUN I 9 FT T o 9 FT CLNG I CLNG M iv W L-------------- REF EID- - 5'—O'XW 0' N RAISED BAR aD CLOSET AHU POCKET-D C-4 5 -4 - DOOR BATH 2-8"XV-o" 9 FT CLN o T-8" LIVINQ ROOM Tn 9 FT, CLNG- o +Cq P aI 5 -4 -0 p CLOSET LINEN o} N 6'—wxs'-0" b I %o 17'-6" r iV 1 BEDROOM 2 2 I 9 FT CLNG -O" 4'-10" 7'-0" 4'-0" DO 01 FRONT PORCH 9 FT CLNG 5 0 6'-5" 6'-5' 4'-10" 6'-4" 6'_8. 12'-10" 17'-10" 30'-8" Q Q I i� 2 s eq 0 I y' �''` r� w J71, I ME`i Q b y' �''` r� w J71, I ME`i Q b "EG'+ o-A 4 p --a ARCHITECTS GENERAL CONTRACTORS A ROUND HILL DEVELOPMENT GROUP COMPANY 17968 115 TH AVE. NORTH JUPITER, FLORIDA 33478 PH: 561-216-1000 CELL 561-718-0831 319 167TH ST NO. MIAMI BEACH, FL. 33162 305-454—BODD WWW. ADVANCED—DESIGN—BUILDING.COM THESE 01141111 AHD SPECIFICATIONS ARE INSTRUMENTS OF SEANCE AND ARE THE PROPER1Y OF ROUND HILL DEVELOPMENT GROUP. IH0. Aba ADVANCED DESIGN k 911111 THEY ARE NOT BE USED ON ANY OTHER PROTECTS OR EMENSIONS OF 1HIS PROJECT DW PT BY TRBTTEN ACREEWENTS VON ROUND HILL DEVELOPMENT GROUP. NO DESIGN CHANCES Wi AL1ER THE INTENT OF THESE ORABTNGS OR SPEDFlCAMNS ARE TO BE MADE WITHOUT OBTAINING PoWTiEN PaNISSIGN FROM ROUND HILL ❑EVLLOPMETa GROUP. z'� cr ARCHITECT: O RNA OF 1:10 y�PKE ARC ARD IQN�S9 Sli AR0018133 CLIENT: SMALL HOUSE PROJECT ' b uL r. _ .M, ,._. ADD>s S, FLOOR PLAN WIN= REVISIONS: DRAWN BY: jaic, CHECKED BY: ;vJ PROJECT i SCALE: j INCH l Zz0 • PAUL WELCHING. MUlmUNOT PLATTED M�crtsseas W eL � su rn►�R�n►c "fo : ' VACANT ftNTSA Lucas, FL�aas4 2�W PAM WaCM.1 E. FfA RXGA(a 29g4 L 0 1 h S31 9'{ 2" 8�.0(}' �y Ow s �oz� 1� Att, �wrl COVERED $ (5 NQ.29945U. . J77 R --ti vi - PORCH vt oc f 30.5,7':`C SSAt� W . _ mac. .^ LOT ipp5`r•, O� • OSED op 1... �OR:Y CBS c4 ,� 'goy C o RESIDENCE �' I a Wz lawo m . c C4 = a, 12.83 di .000 _ � • 1 i. ti. �8�• ,•�LL +ram , y f ' X `" Q�. _� �xp�, .co ` " t � f" • . . ' O ~O t Este:. r' 19,33 ap a 9 �z W �,.''_ 00 _ �. W K W Wes•^ rit�9 't:• ":r,`, r LL. Q p 10 c ,c " � O o , 3a .2 i 7E sii� iQ ral �Or � tj ,`� N ° a0 4SO lei 9 421.71' �o N_ T0091�W 80. _0, ow.447:28s NOT go •FND 42131(P) iry� 420.71'(M) 80.00° I� _. • 447. 28' e. :'.S31'09'�02"E''.. 948- 99' NAIL _NO SITE"BENCHMARK ,� 'NAIL . ,. (SCALE, I"�20`ros NO ID PAINTED . ,X ELE'V= 16.15 -NAVD 1988 PAPAYA. DRIVEz ea /w 71 O.qPWAI T Rnen of [0 (r__0 I -ffW.� 1 TYP-E OF SURVEY:I BOUNDARY I PLOT PLAN I' U/C TIE IN I FOUNDATION I FINAL 1 1 COMPLETED ON: 1 11-12-20 1 11-15-20 1 1 1 1 LEGAL -DESCRIPTION: �I LOT 14 IN BLOCK 79 OF INDIAN RIVER ESTATES UNIT NINE, ACCORDING TO I \VI THE PLAT THEREOF AS RECORDED IN PLAT BOOK 10, PAGE 74, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. ABBREVIATIONS: (C) = CALCULATED 0 (M) = MEASURED (P) = PLATTED CBS = CONCRETE BLOCK STRUCTURE CMP = CORRUGATED METAL PIPE CLF = CHAIN LINK FENCE CNS = COULD NOT SET CONC = CONCRETE FFE = FINISHED FLOOR ELEVATION FND = FOUND 5/8" IRON REBAR M IRC = 5/8" IRON REBAR WITH PLASTIC CAP IR = 5/8" IRON REBAR PCOR = PROPERTY CORNER PL = PROPERTY LINE PUDE = PUBLIC UTILITIES AND DRAINAGE EASEMENT R/W = RIGHT—OF—WAY R = RADIUS OF CURVE L = LENGTH OF CURVE A = DELTA OF CURVE 0 = SET 5/8" IRON ^REBAR WITH PLASTIC �� , -\ 2oy� O., O. \s 2 'PO 9G 9 BY: SCALE: 1 "=30' DATE: 11-12-20 DRAWN: SW JOB NO.: 20-6311 DATE: Ga ar_ • _ APR ) 3 2021 2 O� 0 SURVEYOR'S REPORT: 1. UNLESS OTHERWISE NOTED ONLY PLATTED EASEMENTS ARE SHOWN HEREON. 2. NO UNDERGROUND UTILITIES OR IMPROVEMENTS WERE O LOCATED UNLESS OTHERWISE SHOWN. Z 3. THIS SITE LIES WITHIN FLOOD ZONE "X", ACCORDING TO II THE FLOOD INSURANCE RATE MAP, COMMUNITY PANEL'NO. 12111CO281 K, EFFECTIVE DATE FEBRUARY 19, 2020'.. Q;r 4. FLOOD ZONE SHOWN HEREON IS AN INTERPRETATI,ON.BY THE �U SURVEYOR AND IS PROVIDED AS A COURTESY. THE FLOOD l� ZONE SHOULD BE VERIFIED BY A DETERMINATION AGENCY. U Q 5. BEARINGS SHOWN HEREON ARE BASED ON THE' EAST:LINE _CU OF LOT 14 ASSUMED TO BEAR S31'09`•02"E. 6. ALL LOT DIMENSIONS SHOWN ARE PER•:.•PLAT. JJNLESS OTHERWISE NOTED. ALL SURVEY MEASUREMENTS AREA IN FEET. 7. ALL MAPPED FEATURES SHOWN HEREON ARE UNDER THE DIRECT SUPERVISION AND RESPONSIBILITY OF.ALEXANDER J. PIAZZA PSM, INC. 8. SURVEY MAP AND REPORT OR THE COPIES THEREOF:ARE,NOT• VALID WITHOUT THE ORIGINAL SIGNATURE AND SEAL OF " A FLORIDA LICENSED SURVEYOR AND MAPPER. 9. ADDITIONS OR DELETIONS TO THE SURVEY MAP OR -IF BY OTHER THAN THE SIGNING PARTY OR PARTJES IS' PROHIBITED WITHOUT CONSENT OF THE SIGNING PARTY OR, PARTIES. ,. -J9 pG�Nlk )H in St. Lucie County nvironmental Health I Approved for .Construction :s All Previous ,Site Plans for f*MM-0111$ &Well# ALEXANDER J. PIAZZA PSM, INC. CERTIFIED T0: BELTRAN CONSTRUCTION, INC. Surveying • Mapping • Consulting 619 SW Biltmore Street Port St. Lucie, Florida 34983 ®®®���OER,,,� ® Phone: (772) 340-7770 �P••' se Fax: (772) 340-2250:' , DenN LB I280 FAQ _j ,, 6330, Aj E: 11-11-20 s K:\BUILDERS\DWG2020\20-6311.dwq, 11/18/2020 3:23:49 PM