HomeMy WebLinkAboutGate Operator Detail1) DESIGN AND CONSTRUCTION SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: — FLORIDA BUILDING CODE (FBC) 7TH EDITION (2020) — ASCE 7-16 — THE 2015 ALUMINUM DESIGN MANUAL — DESIGN WIND PRESSURES DERIVED FROM ASCE 7-16 AND PER FBC SECTION 1609 — ULTIMATE WIND SPEED: 170 MPH — RISK CATEGORY. II — EXPOSURE CATEGORY. D — ASTM F2200: STANDARD SPECIFICATION FOR AUTOMATED VEHICULAR GATE CONSTRUCTION. 2) EXPANSION BOLTS SHALL BE GALVANIZED HILTI KWIK BOLTS OR APPROVED EQUAL W/ 4-1/2- MINIMUM EMBED 3) INSULATE ALUMINUM MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 4) CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AFTER 28 DAYS. 5) SOIL BEARING CAPACITY FOR FOUNDATIONS: EXISTING, ASSUMED TO BE WELL COMPACTED AT 2,000 PSF 6) FOOTING HAS BEEN DESIGNED PER FBC 1819.7. 7) ENGINEER HAS NOT VISITED THE JOB SITE AND SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANYWAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS THAT HAVE BEEN PROVIDED BY THE CONTRACTOR. WORK SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. MINIMUM (4) 1/2"0 GLAV. EXPANSION ANCHOR W/ 4-1/2" EMBED EXIST. ±2" 3,000 PSI CONC: FOOTING Z(b6 -o3ss REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY ®CC a U A O A .. Q A d ,d A.. , a d" A a . G I-- MIN. 24" X 24" ---I MEGA ARM GATE OPERATOR GATE ARM (12- MAX LENGTH) i GATE DETAIL - ` •• THIS ITEM HAS BEEN ELECTRONICALLY SIGNED AND SEALED BY EVAN KENNEDY. L :Ipl ••�,�P.E.ON 06-10-21 USING ADIGITAL SIGNATURE C ♦♦�`/�•••�` ♦ • • I PRINTED COPIES OF THIS DOCUMENTARENOTCONSIDEREDSIGNEDAND Nc 69895 SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES. DATE: 06/10/2021 DSGN: E. KENNEDY pa �& K E N N DYG, TLANTIS BY THE SEA : DRWN: E KENNEDY N ENGINEERING, 332 7TH TERRACE LLC • • • ;• ST T��F CHKD: E. KENNEDY SCALE: N.T.S. R BOCA ATON, FL 33486 CA y 29980 • _ 2 OC%�� ••�REMOTE ACCESS MEGA ARM GATE OPERATOR W/ CONCRETE PAD DWG. No. 1 of PH: (561) 573-1679• EMAIL evankennedylOgmail.com ♦ SALES �O�S/�r�'u- �,��� A.) r-&- 0_�3�s GENERAL NOTES: 1) DESIGN AND CONSTRUCTION SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: - FLORIDA BUILDING CODE (FBC) 7TH EDITION (2020). - ASCE 7-16 - THE ALUMINUM DESIGN MANUAL, 2015 EDITION. - DESIGN WIND PRESSURES DERIVED FROM ASCE 7-16 AND PER FBC SECTION 1609 - ULTIMATE WIND SPEED: 170 MPH - RISK CATEGORY: II - EXPOSURE CATEGORY: D 2) ALUMINUM MATERIAL- SHEET METAL IS 5052-H32 UNDER ASTM B209, EXTRUSIONS ARE 6063-T5 UNDER ASTM B221, STRUCTURAL IS 6061-T6 UNDER ASTM 8211 WITH FTY=35KSI AND FTU=38KSI, UNLESS OTHERWISE STATED. ALUMINUM WELDS WILL USE 5356 ALLOY WITH MINIMUM SHEAR STRENGTH OF 17KS1. ALL WELDING TO CONFORM TO AWS STANDARDS. ALL BOLTS AND SCREWS IN CONTACT WITH ALUMINUM ARE STAINLESS STEEL A304/A316 GRADE STAINLESS STEEL SEE CAMERA/RFID OPTIONS RECEIVED JUN 14.1021 3) ALL MEMBERS SHALL BE WELDED W/ MINIMUM 3/16' FILLET WELD, UNLESS NOTED OTHERWISE. ALL WELDING SHALL CONFORM TO AISC STEEL CONSTRUCTION MANUAL 13TH EDITION. 4) INSULATE ALUMINUM MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS. 5) CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3,000 PSI AFTER 28 DAYS. 6) SOIL BEARING CAPACITY FOR FOUNDATIONS: EXISTING, ASSUMED TO BE WELL COMPACTED AT 2000 PSF 7) ENGINEER HAS NOT VISITED THE JOB SITE AND SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANYWAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS THAT HAVE BEEN PROVIDED BY THE CONTRACTOR. WORK SHALL BE FIELD VERIFIED BY THE CONTRACTOR AND THE ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION. permitting Department St. Lucie County N � A 4"X4"XO.125' ALUM. POST FINISH GRADE e z 3,000 PSI CONC. ca 'L(= -1"355 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY �--- CAMERA CAMERA DETAIL SCALE: N.T.S. , "•'N4`X6' ALUM. PLATE W/ C THRU BOLTS TO POLE 3'X3'XO.125' ALUM. TUBE 2'0 X 0.125" ALUM. TUBE RFID READER MAX. 2 SF EFFECTIVE WIND AREA ATTACHED TO POLE RFID DETAIL SCALE: N.T.S. .�,1 I.K­y DIA. MIN. ,i � 111 ,00nmmfeemexxomoaF DDEa tit Evan Ken edyI. , CAMERA/RFID POLE SEq,�;:•KE,NN���i� .. • f�. E N • �, THIS REM NA9 BEEN ELECTRONICALLY SIGNED AND SEALED By EVAN KENNEDY, SCALE: N.T.S. ,,� ••��\ SF••0��� P.E.ONOB-70.2,USWOADIGRALSIGNATIIRE • • j No 69895 - + PRINTED COPIES OF THIS DOCUMENTARE NOT CONSIDERED SIGNED AND SEALED AND THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC CO PIES. DATE: 06/10/2021 DSGN: E. KENNEDY EN E N N DY � = • �'� ; TLANTIS BY THE SEA DRWN: E.KENNEDY CHKD: E. KENNEDY NG, LLC ENGINEERINI TERRACE 3O : i� ; J ST�TE_ ?F SCALE: N.T.S. BOCA RATON, FL 33486 R TO CA y 29980 j 2 wj4 �2EMOTE ACCESS CAMERA/RFID o 1 1 DWG. No. of PH: (561) 573-1679 EMAIL• evankennedylOgmalcom p•��2 s� ��_ s;•• /'£ •%� SALES POLE DETAIL o