FL2569-R22
Revision
2020
Approved
Sopremar Inc, (Canada)
1640 rue Haggarty
Drummondville, NON -US 00000
(819)478-2400
memathieu @scprema.ca
Marc -Etienne Mathieu
memathieu@soprema.ca
Marc -Etienne Mathieu
1688 Jean-Berchmans-Michaud
Drummondville, NON -US 00000
(819) 478-2400 Ext3327
memathieu @soprema.ca
Jean -Francois Cote, Ph.D.
1640 rue Haggerty
Drummondville
(888)811-3145
jfcote@soprema.ca
Roofing
Underlayments
q C-5
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Robert J. M, Nieminen
Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 12/21/2023
Validated By John W. Knezevich, PE
Validation Checklist - Hardcopy Received
Certificate of Independence F 2569 R2 OI 2 21 01 COI NI MJNEN,pdf
Referenced Standard and Year (of Standard) Standard
Year
ASTM D1970
2015
ASTM D4601
2012
ASTM D4798
2011
FM 4474
2011
FRSA/TRI Sixth Edition
2018
TA-5 103
2020
UL1897
2015
https:/lfloridabuilding.org/p ripr_app_dtl, aspx? param=wGEVXQwtDgsKQFEnckB 108E rx1 Ud3xYlr7amGvvoArgg kU4EylLatg%3d %3d 1 /2
8/2/2021
Equivalence of Product Standards
Certified By
Florida Building Code Online
rJ
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
SrirnmAry of Prnrimtrfe
Method 1 option ❑
04/19/2021
04/19/2021
04/26/2021
06/08/2021
07/29/2021
FL #
Model, Number or Name
Description
2569.1
Soprema Roof Underlayments for
Self adhering roof underlayments
use in FBC HVHZ jurisdictions
Limits of Use
I Installation Instructions
Approved for use in HVHZ: Yes
FL2569 R22 II 2021 04 19 FINAL ER SOPREMA HVHZ FL2569-
R22.pdf
Approved for use outside HVHZ; No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER Section 5 for Limits of Use.
Evaluation Reports
FL 5 K2Z A 24 1 04 9 FINAL R SOPREMA HVHZ FL2569-
R22.pdf
Created by Independent Third Party: Yes
2569.2
Soprema Roof Underlayments for
Self adhering roof underlayments
use in FBC non-HVHZ jurisdictions
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL2569 R22 II 2021 04 19 FINAL ER SOPREMA NON -
HVHZ FL2569-R22.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen, P.E. PE-59166
Design Pressure: +N/A/-150
Created by Independent Third Party: Yes
Other: 1.) Refer to ER Section 5 for Limits of Use. 2.)
Evaluation Reports
The design pressure noted herein pertains to
FL2569 R27 AF 2021 04 19 FINAL ER SOPREMA NON-
HVHZ FL2569-R22.pdf
underlayment systems used beneath adhesive -set We
systems. Refer to ER Section 5.8.3 for details.
Created by Independent Third Party: Yes
Contact Us :: 2601 Biair Stone Road, Tallahassee FL 32399 Phone: 850-467-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Prlvary Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are publ fc records. If you do not want your e-mail address reieased in response to a publfc-records request, do not send electronic
mail to this entity. instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1),
Florida Statutes, effective October 1, 2022, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
provide the Department with an email address which car be made available to the pubt[c. To determine if you are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts:
gCi
Credit; Card
Safe
https://floridabuilding.org/prlpr_app_dtl.aspx7param=wGEVXQwtDgsKOFEnckBI08Erx1Ud3xYlr7amGvvoArggkU4EylLatg%3d%3d 212
NEMOI etc.
Certificate of Authorwation 432455
353 Christian Street, Unit #13
Oxford, CT 06478
(203) 262-9245
ENGINEER EVALUATE TEST CONSULT
DLLIATION RFPnP
SOPREMA, Inc. Evaluation Report 3m-SOPC-2I-FBCER.A
1640 rue Haggerty FL2569-R22 (HVHZ)
Drummondville, Qu6bec 12C 5P8 Canada Date of Issuance.• 04/19/2021
(819) 478-2400
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 7t" Edition Q020) Florida Building Code, High Velocity
Hurricane Zone sections noted herein.
DESCRIPTION: SOPREMA Roof Underlayments for use in FBC HVHZ jurisdictions
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein
and FBC 1507.1.1.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality
Assurance or production facility location(s) changes, or Code provisions that relate to the product(s) change. Acceptance of
our Evaluation Reports by the named client constitutes agreement to notify NEMO ETC, LLC of any changes to the product(s),
the Quality Assurance or the production facility location(s). MEMO ETC, LLC requires a complete review of its Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Florida Product Approval Number (FL#) preceded by the words "NEMOIetc. Evaluated" may be displayed
in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7
Prepared by:
Robert J.M. Nieminen, P.E. The facsimile seal appearing was authorized by Robert Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983 on 04/19/2021. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
I. NEMO ETC, LLC does not have, nor does it intend to acquire or with it acquire, a financial interest in any company manufacturing or distributing
products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the
evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product.
5. This is a building code evaluation. 'Neither NEVIO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on
which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that
purpose.
C2019 NEMO ETC, LLC
OMEMO I etc.
ROOFING COMPONENT EVALUATION:
SCOPE:1.
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement: SOPREMA Roof Underlayments, as produced by SOPREMA, Inc., have
demonstrated compliance with
the fallowing sections of the 7`h Edition (2020) Florida Building
Code, High Velocity Hurricane Zone through testing in
accordance with the following Standards. Compliance is subject
to the Installation Requirements and Limitations / Conditions
of Use set forth herein.
2. STANDARDS:
Sectiori
Property
Standard
Year
TAS 110
Material standard
ASTM D1970
2015
TAS 110
Material standard
ASTM D4601
2012
TAS 110
Material standard
TAS 103
2020
TAS 110
Accelerated Weathering
ASTM D4798
2011
3. REFERENCES:
Entit
Examination
Reference
Date
ERD (TST6049)
TAS 103 (MS)
543530.02.14-1-R1
02/21/2014
ERD (TST6049)
ASTM D1970 (QC)
S44870.04.14-3
04/02/2014
ERD (TST6049)
ASTM D1970 (OH)
S44870.04.14-1
04/10/2014
ERD (TST6049)
ASTM D1970 (MS)
544870.04,14-4
04/10/2014
ERD (TST6049)
ASTM D1970 (OH)
S40540,10.14
10/31/2014
ERD (TST6049)
Tensile Adhesion / Long Term Aging
SOPC-SC7645.02.15
02/13/2015
ERD (TST6049)
ASTM D4798
SOPC-SC8520.04.14
04/27/2015
N E M 0 (TST6049)
ASTM D1970/TAS 110 (QC)
SOPC-SC8970.08.15-RI
04/25/2018
NEMO (TST6049)
Tile Slippage
4S-SOPC-18-002.09.18
09/21/2018
NEMO (TST6049)
ASTM D4601 (MS)
4q-SOP-I9-5SM1313-01.A
03/11/2019
NEMO (TST6049)
ASTM D4601 (OH)
4q-SOP-I9-SSMBB-01.B
03/11/2019
NEMO (TST6049)
ASTM D4798/D1970 (OH & MS)
4S-SOPC--18-002.05.19.A
05/31/2019
NEW (TST6049)
Tensile Adhesion / Long Term Aging
4p-DOW-I9-SSLAP-01.A.R2
02/10/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-I9-SSUDL-04.A
03/12/2020
NEMO (TST6049)
Peel adhesion (existing underlayments)
4j-SOPC-20-SSUDL-01.A
01/07/2021
NEMO (TST6049)
ASTM D1970 (MS)
4j-SOPC-2I-SSUDL-01.A
04/19/2021
PRI (TST5878)
ASTM D1970 (MS)
SOP-064-02-01
12/03/2013
Soprema, Inc. (PDM3511)
Equivalency Declaration
SA SMOOTH PLY 40
06/29/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R16814
12/10/2015
UL, LLC (QUA9625)
Quality Control
MLA File No. R27605
05/08/2019
UL, LLC (QUA9625)
Quality Control
Service Confirmation
06/29/2020
UL, LLC (QUA9625)
Quality Control
Florida BCIS
Current
4.1
4.2
4.3
4.4
PRODUCT DESCRIPTION'.
Product
Material Standard
Plant(s)
Description
LASTOBOND TU HT
ASTM D1970 and
Gulfport, MS
self -adhering, non -woven polyester fabric surfaced, SBS
TAS 103
modified bitumen roof underlayment
Tri-Built S/A HT TU
ASTM D1970 and
Gulfport, MS
self adhering, non -woven polyester fabric surfaced, SBS
Underlayment
TAS 103
modified bitumen roof underlayment
LASTOBOND Shield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS modified
bitumen roof underlayment available in two widths; 36 and
45 inch
RESISTO SA SMOOTH PLY 40
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, SBS modified
bitumen roof underlayment
NEMO ETC, U.C. Evaluation Report 3m-SOPC-2I-FBCER.A
Certificate of Authorization #32455 7TH EDITION (2020) FBC HVHZ EVALUATION FL2569-R22 {HVH2)
SOPREMA Roof Underlayments Revision 0: 04/19/2021
Page 2 of 7
M
4.5
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
4.17
4.18
14NEM01eft
PRODUCT
Product
Material Standard
Plant )
Description
LASTOBOND Shield HT
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof underlayment
LASTOBOND Pro HT-N
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, 565 modified
bitumen roof underlayment available in two widths; 36 and
45 inch
LASTOBOND Pro HT-S
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof underlayment
EnviroShield
ASTM D1970
Drummondville, QC
self -adhering, woven polyethylene surfaced, high
temperature, SBS modified bitumen roof underlayment
LASTOBOND Eco
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
LASTOBOND Smooth Seal HT
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced, SBS
Wadsworth, OH
modified bitumen roof underlayment
Tri-Built Smooth HT S/A
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced, SBS
Underlayment
Wadsworth, OH
modified bitumen roof underlayment
PrimeSource Grip -Rite
ASTM D1970
Gulfport, MS
self -adhering, glass -mat reinforced, film -surfaced, SBS
Smooth Seal HT
Wadsworth, OH
modified bitumen roof underlayment
RESISTO LB1236
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
TRI-BUILT Sand-R SA Shingle
ASTM D1970
Drummondville, QC
self adhering, glass -mat reinforced, sand -surfaced, SBS
Underlayment
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
PrimeSource Grip -Rite Eave
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
& Valley Protector
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
SRS TopShield ICE & WATER
ASTM D1970
Drummondville, QC
self adhering, glass -mat reinforced, sand -surfaced, SBS
DEFENDER
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
RESISTO LB1244
ASTM D1970
Drummondville, QC
self -adhering, glass -mat reinforced, sand -surfaced, SBS
Gulfport, MS
modified bitumen roof underlayment
Wadsworth, OH
MODIFIED SOPRA-G
ASTM D4601, Type II
Gulfport, MS
Fiberglass reinforced, SBS modified asphaltic base sheet
Wadsworth, OH
5. LIMITATIONS:
5.1 This is a Building Code Evaluation, Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record
for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance
unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FSC Non -High Velocity Hurricane Zone jurisdictions (i.e., outside of Broward and Miami -
Dade Counties),
5.3 This Evaluation Report pertains to above -deck roof components. Roof decks and structural members shall be in accordance
with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1516 for requirements and limitations
regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam
plastic insulation.
NEMO ETC, LLC. Evaluation Report 3m-50PC-21-FBCER.A
CertifrcateofAuthoriwtion #32455 7T" EDITION (2020) FBC HVHZ EVALUATION FL2969-R22 (HVH2)
SOPREMA Roof Underlayments Revision 0: 04/19/2021
Page 3 of 7
ONEMOjetC.
5.5 SOPREMA Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within
FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this
evaluation combined with supporting data for the prepared roof covering.
5.6 Allowable Roof Covers:
TABLE 1: ROOF COVER OPTIONS
FUC Section.
TAS 110(SIO),
RAS 115
TAS 110(511),
RAS 118,119 & 120
RAS 133
TAS 110(S11j
RAS 130
Clay and Concrete Tile
Underlayment
Asphalt
Shingles Shingles
Metal
Slate or Slate -
Wood
Mechanical
Adhesive-
Attach
Set
Type Shingles
LASTOBOND TU HT, Tri-Built S/A HT TU
Yes
Underlayment
Yes
Y
Yes
See 5.6.1
Yes
Yes
Yes
LASTOBOND Shield, Pro HT-N, RESISTO SA
SMOOTH PLY 40
Yes
No
No
Yes
Yes
Yes
LASTOBOND Shield HT, Pro HT-S
Yes
No
No
Yes
Yes
Yes
EnviroShiield
Yes
No
No
Yes
Yes
Yes
LASTOBOND ECO, RESISTO L91236, TRI-
BUILT Sand-R SA Shingle Underlayment,
Grip -Rite Eave & Valley Protector,
Yes
No
No
No
Yes
Yes
TopShield ICE & WATER DEFENDER,
RESISTO LB1244
LASTOBOND Smooth Seal HT, Tri-Built
Smooth HT S/A Underlayment, Grip -Rite
Yes
No
No
Yes
Yes
Yes
Smooth Seal HT
5.6.1 Adhesive -set tile is limited to use of the following underlayment / tile -adhesive combinations.
TABLE 1A: ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS'
Underlayment
Adhesive
Florida Product Approval
LASTOBOND TU HT, Tri-Built S/A HT TU
Underlayment
Dupont "Tile BondT' Roof Tile Adhesive"
FL22525
ICP Adhesives and Sealants "Polyset® AH-160"
NOA 20-1124.07
5.7 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Substrates [designed to meet wind loads for projectj
Type
Printer
Material(s)
LASTOBOND Shield, LASTOBOND Pro HT-N,
Deck
ASTM D41
structural concrete
RESISTO SA SMOOTH PLY 40, LASTOBOND
Dens Deck Prime or SECU ROCK
Shield HT, LASTOBOND Pro HT-S,
Insulation
(Optional) Elastocol Stick Zero
EnviroShield, LASTOBOND TU HT, Tri-Built S/A
Gypsum -Fiber Roof Board
HTTU Underlayment, LASTOBOND ECO,
RESISTO L61236, TRI-BUILT Sand-R SA Shingle
self-
Underlayment, Grip -Rite Eave & Valley
adhering
Protector, TopShield ICE & WATER
Base Sheet
(Optional) Elastocol Stick Zero
ASTM D226, Type II felt
DEFENDER, RESISTO LB1244, LASTOBOND
Smooth Seal HT, Tri-Built Smooth HT S/A
Underlayment or Grip -Rite Smooth Seal HT
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC. Evaluation Report 3m-SOPC-2I-FBCER.A
Certificate of Authorization #32455 77H EDITION 12020) FBC HVHZ EVALUATION FL2569-R22 (HVHZ)
SOPREMA Roof Underlayments Revision 0: 04/19/2021
Page 4 of 7
*Nwojetc,
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Substrates (designed to meet wind loads for project)
Underlayment Application
Type Primer Material(s)
LASTOBOND TU HT, Tri-Built S/A HT TU
Underlayment, RESISTO L61235, TRI-BUILT SExisting sand -surfaced, glass -fiber
adhering Sand-R SA Shingle Underlayment, Grip -Rite dh Existing RESISTO EXTERIOR PRIMER surfaced, mineral -surfaced or
Eave & Valley Protector or TopShield ICE & ering substrate
film -surfaced roof underlayment
WATER DEFENDER
* Final acceptance of any existing substrate in a reroof (tear -off) installation is at the discretion of the installer and the Authority Having Jurisdiction. Should a
question arise as to the suitability of on existing substrate to receive LASTOBOND TU HT Tri-Built S/A HT TU Underlayment RESISTO L81236, TRI BUILT Sand-R SA
Shingle Underlayment Grip -Rite Eove & Valley Protector or TopShield ICE & WATER DEFENDER self -adhering underloyments, contact RESISTO technical support.
5.8 Attachment Limitations:
Refer to Section 6
5.9 Exposure Limitations:
TABLE 3: EXPOSURE LIMITATIONS
Underlayment
LASTOBOND Eco, RESISTO LB1236, TRI-BUILT Sand-R SA Shingle Underlayment, Grip -Rite
Eave & Valley Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244
LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield
HT, LASTOBOND Pro HT-S, EnviroShield, LASTOBOND Smooth Seal HT, Tri-Built Smooth HT
S/A Underlayment or Grip -Rite Smooth Seal HT
Prepared Roof Cover
Installation Type
Maximum
Exposure (days)
Mechanically attached
30
Mechanically attached 1 90
LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment Mechanically attached or 180
adhesive -set tile roof system
SAO Tile Slippage Limitations: When loading roof tiles on the underlayment in direct -deck tile roof assemblies, the maximum roof
slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
TABLE 4: TILE SLIPPAGE LIMITATIONS FOR DIRECT -DECK TILE INSTALLATIONS
Underlayment Tile Profile Staging Method Maximum Slope
Flat Max. 10-tile stack 6:12
Lugged Max. 10-tile stack 5:12
Double -tile stacking method, as shown below 6:12
LASTOBOND TU HT, Tri-
Built S/A HT TU
Underlayment Lugged
NEMO ETC, LLC. Evaluation Report 3m-5OPC-2I-FBCER.A
Certificate of Authorization #32455 7T" EDITION (2020) FBC HVFIZ EVALUATION FL2569-R22 {HVHZ)
SOPREMA Roof Underlayments Revision 0: 04/19/2021
Page 5 of 7
ONEMOIetc.
6.1 SOPREMA Roof Underlayments shall be installed in accordance with SOPREMA published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust
and debris prior to application, and prime the substrate (if applicable).
6.3 A roved Assemblies:
6.3.1 Deck Type 1:
Wood, Non -Insulated
Beck Description:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of FBC HVHZ Approved ASTM D226, Type 11 felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a staggered grid -pattern between the overlaps.
Cap Ply:
LASTOBOND TU HT or Tri-Built S/A HT TU Underlayment, self -adhering and back -nailed max. 12-inch
O.C. using FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5),
Surfacing:
FBC HVHZ Approved mechanically attached or adhesive -set tile roof system. Refer to Table 1A for
allowable tile adhesives and Table 4 for tile stagging limitations.
6.3.2 Deck Type 1:
Wood, Non -Insulated
Deck Descrip#ion:
Min. 19/32" plywood or wood plank
System Type E:
Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet:
One or more plies of FBC HVHZ Approved ASTM D226, Type II felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening:
FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a staggered grid -pattern between the overlaps.
Cap Ply:
LASTOBOND Shield, LASTOBOND Pro HT-N, RESISTO SA SMOOTH PLY 40, LASTOBOND Shield HT,
LASTOBOND Pro HT-S, EnviroShield, LASTOBOND TU HT, Tri-Built S/A HT TU Underlayment,
LASTOBOND Smooth Seal HT, Tri-Built Smooth HT S/A Underlayment or Grip -Rite Smooth Seal HT, self -
adhering.
Surfacing:
FBC HVHZ Approved asphalt shingles, metal panels, metal shingles, slate, slate -type shingles, wood
shakes or wood shingles.
6.3.3 Deck Type 1: Wood, Non -Insulated
Deck Description: Min. 19/32" plywood or wood plank
System Type E: Base sheet mechanically fastened to deck; underlayment adhered to base sheet
Base Sheet: One or more plies of FBC HVHZ Approved ASTM D226, Type 11 felt or MODIFIED SOPRA-G with a
minimum 4-inch side lap and 6-inch end lap, mechanically fastened to deck.
Fastening: FBC HVHZ Approved nails and tin caps (FBC HVHZ 1517.5), 6-inch o.c. at the lap -edges and 12-inch o.c.
in a staggered grid -pattern between the overlaps.
Cap Ply: LASTOBOND ECO, RESISTO L81236, TRI-BUILTSand-R SA Shingle Underlayment, Grip -Rite Eave & Valley
Protector, TopShield ICE & WATER DEFENDER or RESISTO LB1244, self -adhering.
Surfacing: FBC HVHZ Approved asphalt shingles, slate, slate -type shingles, wood shakes or wood shingles.
NEW ETC, LLC. Evaluation Report 3m-50PC-2I-FBCER.A
Certificate of Authonzativn #i32455 7"' EDITION (2020) FBC HVHZ EVALUATION FL2569-R22 (HVHZ)
SOPRENIA Roof Underlayments Revision 0: 04/19/2021
Page 6 of 7
ONEMOjetc.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product.
Contact the named QA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 QA requirements. Refer to Section 4
herein for products and production locations having met codified material standards.
UL LLC—QUA9625; (434) 248-6409; Karen.buchmannCtt�ul.Com
- END OF EVALUATION REPORT -
MEMO ETC, LLC. Evaluation Report 3m-SOPC-21.FBCER.A
Certificate ofAvthorizotion #32455 7"" EDITION (2020) FBC HVHZ EVALUATION FL2569,R22 (HVH2)
SOPREMA Roof Underlayments Revision 0: 04/19/2021
Page 7 of 7