Loading...
HomeMy WebLinkAboutVentilation Calculation Letter eSEALDesign Report Prepared for My Florida Roofing Contractor Calculations by Seaside Engineers Project: Single Family Residence Certificate of Authorization No. 32048 Location: 7005 Arthurs Road 4265 60th Court Fort Pierce, Florida Vero Beach, Florida 32967 Project ID:(722) 202‐8008            info@seasideengineers.com Date:  8/2/2021 www.seasideengineers.com Ventilation Calculation Roof Perimeter 307 ft (measured from the roof report) Attic Area 2659 sqft (measured from the roof report) 2659 SQFT Total (Intake and Exhaust) Soffit (Intake) Roof (Exhaust) 1:300 per US FHA (REQUIRED) 8.86 SQFT = 1276.32 SQIN 4.43 SQFT = 638.16 SQIN 4.43 SQFT = 638.16 SQIN 1:150 (RECOMMENDED) 17.73 SQFT = 2552.64 SQIN 8.86 SQFT = 1276.32 SQIN 8.86 SQFT = 1276.32 SQIN Required ventilation per foot of soffit = 2.079 sqin Diameter core in soffit: 4 in Area of core = 12.560 sqin Core required every 6.04 feet in the soffit VENTILATION CALCULATION Attic Area Ventilation Calculation (50% Intake, 50% Exhaust) Provide exhaust and intake ventilation that meets or exceeds the requirements above