HomeMy WebLinkAboutWolflube - Bldg 1 241757-1 DT-dsUES Project No:
Workorder No:
Report Date:
3310.2100259.0000
241757-1
08/13/2021
607 Northwest Commodity Cove, Port St. Lucie, FL 34986 - P: 772-924-3575 - F: 772-924-3580
In-Place Density Test Report
Client:Panelli Fort Pierce, LLC UES Technician:Branden Pyke
16460 SW 137th Avenue
Miami, FL 33177
Date Tested:08/13/2021
Project:CMT Wolflube Warehouse-Manufacturing Building Phase I
Post Office Road, Fort Pierce, St. Lucie County, FL 34981
Type of Test:
Area Tested:Bldg 1 - 4774 South Jenkins Road, Ft.
Pierce, FL
Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Fill
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 Center 0-1 ft 105.2 11.5 103.9 11.2 99 Pass
2 SW corner 0-1 ft 105.2 11.5 103.8 11.4 99 Pass
3 NE corner 0-1 ft 105.2 11.5 103.2 11.1 98 Pass
Reviewed By
GFA International, Inc
FBPE Registry No.4930
Thomas Dominic Montano
Branch Manager
STATE OF FLORIDA
Professional Engineer No. 84146
This item has been digitally signed and sealed by Thomas Dominic
on the date adjacent to the seal. Printed copies of this document are
not considered signed and sealed and the signature must be
verified on any electronic copies.
To establish a mutual protection to Universal's clients, the Public and ourselves, all reports are submitted as confidential property of our clients and
authorization for publication of statements, conclusions or extracts from or regarding Universal's reports is reserved pending our written approval.
Page 1
Remarks: Permit: 2012-0558