Loading...
HomeMy WebLinkAboutBUILDING PERMIT APPLICATIONAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 8/11/21 Permit Number: 1�ir L-�UCIlC O g �^ Building Permit Application Planning and Development Services Building and Code Regulation Division Commercial Residential 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 PERMIT APPLICATION FOR: WATER HEATER REPLACEMENT PROPOSED IMPROVEMENT LOCATION: X Address: Property Tax ID #:1414-610-0051-000-9 Lot No. Site Plan Name: Project Name: Block No, DETAILED DESCRIPTION OF WORK: 47GAL GALLON ELECTRIC WATER HEATER REPLACEMENT (LIKE FOR LIKE) New Electrical Meter Second Electrical Meter [CONSTRUCTION INFORMATION: Additional work to be performed under this permit— check all that apply: _Mechanical Electric Gas Tank _XPlumbing Total Sq. Ft of Construction: Cost of Construction: $ $1982.79 Gas Piping Sprinklers Shutters _ Generator Sq. Ft. of First Floor: Windows/Doors _ Pond Roof Pitch Utilities: _ Sewer _ Septic Building Height: OWNER/LESSEE: CONTRACTOR: NameSTEPHEN PAPA Name. RICHARD BASSOFF Address:1722 VICTORIA WAY Company: ADMIRALPLUMBING SERVICE, ASERVICE EXPERTS COMPANY Address: 2895 JUPITER PARK DR #700 City: SAN MAR('.(),'; State: CA Zip Code: 92069 Fax: Phone No. 520-820-7713 City: JUPITER State: FL zip Code: 3345E Fax: Phone No 561-225-3356 E-Mail:_ GORGO38STEVE@AOL.COM Fill in fee simple Title Holder on next page ( if different from the Owner listed above) E-Mail 208PERMITT[NG@SERVICEEXPERTS.COM State or County License CFC1426115 If value of construction is 2500 or more, a RECORDED Notice of Commencement is required. If value of HAVC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: Not Applicable Name: MORTGAGE COMPANY: Not Applicable Name: Address: Address: City: State: Zip: Phone City: State: Zip: Phone: FEE SIMPLE TITLE HOLDER: Not Applicable Name: BONDING COMPANY: Not Applicable Name: Address: Address: City: City: Zip: Phone: Zip: Phone: OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure which is in conflict with any applicable Home Owners Association rules, bylaws or and covenants that may restrict or prohibit such structure. Please consult with your Home Owners Association and review your deed for any restrictions which may apply. In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrency review: room additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for improvements to your property. A Notice of Commencement must be recorded in the public records of St. Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult with lender or an attorney before commencing work or recording; your Notice of Commencement. ig ature of 0 e ssee/Contractor as Agent for Owner S6 n ture of ConXiFArAicense Holder STATE OF FLORIDA STATE OF FLORIDA COUNTY OF PALM BEACH COUNTY OF PALM BEACH Sworn to (or affirmed) and subscribed before me of Sworn to (or affirmed) and subscribed before me of x Physical Presence or Online Notarization x Physical Presence or Online Notarization this 1-L day of Al IGI IST , 202q by this 1-1- day of AUGUST 2021 by RICHARD BASSOFF RICHARD BASSOFF Name of person making statement. Name of person making statement. Personally Known x OR Produced Identification Personally Known x OR Produced Identification Type of Identification Type of Id ntification Pr cited Pro ce Q_Z/)� /IIIL { — ublic- 5ta F i a g ature of NrGG233 ature of N ry Public- State of Flori a i50 ov n iary Public State of Fio Cmmission N=� (fey queline Georgescu d ��O+ a tary Pubhc state of F rTNI11551On GG233150 �8cqueline Georc�ss My Commission GG 2331 Expires 06f2812022 0 al My Commission GG 2s � Expires 06123112022 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED ev. Admiral Plumbing Services Estimate 80104291 A Service Experts Company Job 74187311 PLUMBING S[Ek ' 2895 Jupiter Park DR #700 Estimate Date 8/11/2021 A SaI*B EqKwts Company Jupiter, FL 33455 Customer PO 561-746-1180 License: CFC 1426115 Billing Address Job Address Stephen Papa Stephen Papa 5047 North Highway A1A #1003 5047 North Highway A1A #1003 Fort Pierce, FL 34949 USA Fort Pierce, FL 34949 USA Estimate Details 50 gallon low boy Task # Description Quantity Your Price Your Total ELCWHSTD-L3 New Electric Water Heater - Standard Size 20-50 Gallon excluding 50 Gallon Low Tanks or 1.00 $1,767.79 $1,767.79 Custom Sizes (See Premium / Custom Option) 6 Year Manufacturers Warranty (Upgrade to Premium for 10 Year) Access to heater is limited or in a location that is not easily accessible / Connections for water and/or electrical are difficult to retrofit *MUST ADD: Required Permit to Meet Local Municiple, County and State Building Codes *MUST ADD: Installation Packages to meet Job Demands & Requirements Permit WH Water Heater - Permit 1.00 $225.00 $225.00 *Required by Building Department Sub -Total $1,992.79 Tax $0.00 Total $1,992.79 Terms: ALL ESTIMATES ARE GOOD FOR 30 DAYS. All material is guaranteed to be as specified. All work is to be completed in a professional manner according to standard practices. Any alteration or deviation from above specifications involving extra costs will be executed only upon written orders and will become an extra charge over and above the estimate. All agreements contingent upon delays, beyond our control. All payments are due upon completion of installation. All payments not received upon completion are subject to 1 1/2% service charge per month, or the maximum rate permitted by law, whichever is less. In the event of non-payment, all costs incidental to collection, including without limitation reasonable attorney's fees shall be added to the unpaid balance. * *CANCELLATION OF WORK AFTER DEPOSIT IS PAID: In the event a job is cancelled after the deposit is paid, a refund will be given minus any permit (if applicable) and administrative fees that were paid by Admiral Plumbing. This is an electronic signature. Please type your first and lastv.ame. Customer Signature: / 1 1 The new degree of comfort® Professional Classic® electric water heaters are engineered for longer life - resistored heating elements and premium grade anode rod Efficiency •.90-.93UEF • Isolated tank design reduces conductive heat loss • Resistored copper upper element and resistored Lifeguard" stainless steel lower element to prolong anode rod and tank life Performance • FHR: 45 - 67 gallons, based on gallon capacity • Recovery: 21 GPH at a 90' F rise System Sentinel (Available on selected models) • Exclusive diagnostic system with glowing LEDs that verify heating element operation. LEDs pin point the exact location of functioning or non- functioning heating elements Longer Life • Premium grade anode rod provides long-lasting tank protection Features • Electric junction box located above heating elements for easy installation • Over -temperature protector cuts off power in excess temperature situations • Automatic thermostat keeps water at desired temperature Plus... • Rheemglas® tank lining resists corrosion and prolongs tank life • EverKleen'M self cleaning device fights harmful sediment build-up with a high -velocity spiraling water stream — helps operating efficiency by saving energy, money and improving tank life • Enhanced -flow brass drain valve • Temperature and pressure relief valve included • HUD certified for manufactured housing and modular construction • Low lead compliant Warranty • 6-Year limited tank and parts warranty* • With Protection Plus" the 6-year limited tank warranty becomes 10-year *See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to the AHRI Operations Manual and D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. Residential Electric Water Professional Classic Water Heaters Professional Classic 19.9 to 55-Gallon Capacities 240 Volt AC/Single Phase Double and Single Element Models Electric See specifications chart on back. PRINTED IN U.S.A. 05/18 WP FORM NO. PROE RH N Rev. 8 Residential Electric Water Professional Classic Water Heaters The new degree of comfort' Professional Classic® Specifications DESCRIPTION FEATURES ROUGHING IN DIMENSIONS (SHOWN IN INCHES) ENERGY INFO. T Y P E NOMINAL RATED GALLON GALLON CAPACITY CAPACITY MODEL NUMBER UEF FIRST HOUR RATING G.P.H. RECOVERY IN G.P.H. 90' F RISE TANK HEIGHT A HEIGHTTO WATER CONN. B DIAMETER C APPROX. SHIP WT. (LBS.) UNIFORM ENERGY FACTOR (UEF) Tall 30 27 PROE30 T2 RH95t 46 21 47-1/2 50-3/8 19-1/4 92 0.92 Tall 40 36 PROE40 T2 RH95t 55 21 60-3/4 63-5/8 19-1/4 109 0.93 Tall 50 45 PROE50 T2 RH95t 63 21 58-5/8 61-5/8 20-1/4 121 0.93 Tall 55 55 PROE55 T2 RH94t 72 21 57 59-3/4 22-1/4 128 0.92 Med. 30 27 PROE30 M2 RH95t 45 21 37-1/2 40-1/2 20-1/4 92 0.90 Med. 40 36 PROE40 M2 RH95t 55 21 48-1/4 50-1/2 20-1/4 106 0.93 Med. 50 45 PROE50 M2 RH95t 62 21 48 50-1/2 23 132 0.93 Short 19.9 - PROE20 S2 RH - 21 31-1/2 31-1/2 17 62 - Short 28 25 PROE28 S2 RH95 45 21 30 31-1/8 23 95 0.92 Short 30 27 PROE30 S2 RH95 13- 46 21 30-1/8 32 19-3/4 95 0.92 Short 36 33 PROE36 S2 RH95 46 21 31-1/2 33 24-1/4 118 0.92 Short 38 35 PROE38 S2 RH95 1 51 21 31-1/2 32-5/8 23 108 0.92 Short 47 43 PROE47 S2 RH95 54 21 32 34 26-1/4 149 0.93 Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. t System Sentinel optional. Add EC1 to the end of the model number. System Sentinel not available on single element models, available on dual element models only. System Sentinel not available in excess of 5 kW on 208 V models. " Water heater dimensions prior to installing insulation blanket that is included with water heater. • Heaters furnished with standard 240 volt AC, single phase non -simultaneous wiring, and 4500 watt upper and lower heating elements. • If heating elements of different wattages than those shown are demanded by zone requirements, they must be specifically requested. • Single element models available on special order (6000W max.). Substitute "1" for "2" in model number. • Special Wiring Options - A limited number of special wiring options are available. Consult factory for price and availability. • All models equipped with heat traps. Recovery = wattage/2.42 x temp. rise °F. Example: 450OW = 21 GPH 2.42 x 90' Recovery calculations used are based on 4500 watt elements used in non -simultaneous operation. $„ HOT WATER COLD CONNECTION WATER RELIEF VALVE CONNECTION CONNECTION ANODE ROD DIA METER Q1 B WATER CONNECTIONS ALL 3/4" N.P.T. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com PRINTED IN U.S.A. 05/18 WP FORM NO. PROE RH N Rev. 8