HomeMy WebLinkAboutRevisions, Design Report Design. Report
Prepared for.My Florida Roofing Contractor Calculations:by,Seaside Engineers
Project:Single Family Residence Certificate of Authorization No.32048
Location: 7005 Arthurs Road 4265 60th Court
Fort Pierce,Florida Vero Beach,Florida 32967
Project ID: (722)202-8008 info@seasideengineers.com
Date: 8/2/2021 www.seasideengineers.com
Ventilation Calculation
Roof Perimeter 307 ft(measured from the roof report)
Attic Area 2659 sqft(measured from the roof report)
VENTILATION CALCULATION.
Attic Area 2659 SQFr
Ventilation Calculation(50%Intake,50%Exhaust)
Total(Intake and Exhaust) Soffit(Intake) Roof(Exhaust)
1:300 per US FHA(REQUIRED) 8.86 SQFT=1276.32 SQIN 4.43 SQFT=638.16 SQIN 4.43 SQFT=638.16 SQIN
1:150(RECOMMENDED) 17.73 SQFT=2552.64 SOJN 8.86 SQFT=1276.32 SQIN 8.86 SQFT=1276.32.SQIN
Provide exhaust and intake ventilation that meets or exceeds the requirements above s
Required ventilation per foot of soffit= 2.079 sqin
Diameter core in soffit: 4 in
Area of core= 12.560 sqin
! EV 1 1 " N
Core required every 6.04 feet in the soffit'
REVIEWED FWOR
G D E G0 M FLIA N C
SM LNIE COUNTY
C 121
saw
�1 •......® O ,
.•
No.72228 L
•• 0 I�:O••�` ``