HomeMy WebLinkAboutProject InformationProject Summary Job: 7202 Deer Park Ave -1449 B RiG -S -�- wrightsoft° Date: 07123120 House By., ww One Stop Cooling and Heating 7225 Sand—Dour(Wlnter Park FL32792 Phone: (407)629. 6920 F-(407)629-9307 Mb:-0neS1opCoo1ingw Uoenae:CPC1817652 Project For. CENTURY COMPLETE 7202 DEER PARKAVE, FL Notes: Design Information Weather. FL, Fort Pierce Winter Design Conditions Outside db 43 'F Inside db 68 °F Design TO 25 °F Heating Summary Structure 12266 Btuh Duds 1296 Btuh Central vent (0 dim) 0 Btuh (none) Humidification 0 Btuh Piping 0 BWh Equipment load 13562 BWh Infiltration Method Simplified Construction quality Semi -fight Fireplaces 0 Heating Cooling Area (fit 1422 1422 Volume (ft) 11378 11378 Airdlangesrhour 0.31 0.16 Equiv.AVF (dim) 59 30 Heating Equipment Summary Make Carrier Trade Model CH14NBO2400GOA0 AHRI ref 9162301 Eftidency 8.2 HSPF Heating input Heating output 22200 Btuh @47-F Temperature rise 0 'F Actual airflow 0 dim Airflowfactor 0 dmlBWh Staticpressure 0 in H2O Space thermostat Capacity, balance point = 31 °F Backup: Input=13kW, Output=43093 Btuh, 100AFUE Summer Design Conditions Outside db 91 °F Inside db 74 °F Design TO 17 °F Daily range L Relative humidity 50 % Moisture difference 61 grub Sensible Cooling Equipment Load Sizing Structure 13714 Btuh Duds 2698 Btuh Central vent (0 dim) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Equipment sensible load 15690 Btuh Latent Cooling Equipment Load Sizing Structure 3664 BWh Duds 739 BWh Central vent (0 dim) 0 Btuh (none) Equipment latent load 4403 Btuh Equipment Total Load (Sen+Lat) 20093 Btuh Req. total capacity at 0.75 SHR 1.7 ton Cooling Equipment Summary Make Carrier Trade Cond CH14NBO2400GOA0 Coil FB4CNP025L AHRI ref 9162301 Efidency Sensible cooling Latent cooling Total cooling Actual airflow Airflowfactor Static pressure Load sensible heat ratio Calculations approved byACCA to meetall requirements of Manual J 8th Ed. 11.5 EER,14.5 SEER 16650 Btuh 5550 Btuh 22200 Btuh 740 dim 0.045 dm/BWh 0.50 in H2O 0.79 II7ft50fY" 2021-Feb-0115:1922 Wr1 ��1/ 'r gRigM-6u,e,, r6e _,20191902ORS1R3249 Pagel ACIM ...arkAe17202Deer ParkAm-1449 B RHG-SM GaIC-MA Front Door hoes S - wrightsoft• Right -A) Worksheet Job: 7202 Deer Park Ae-1"S BRHG-S Date: 07123120 House By. ww One Stop Cooling and Heating 7225 Sandeoaw Court, WnWr Park Ft 32792 Phone: (407) 629- 6920 Fax(407)629-9307 Web:t On4StupCooing.mm ucenw: CACIS17652 1 2 3 4 5 Room name EVoeadwal Room height Roomdmenaons Room area House 137.0 4 8.0 ft d 1422.3 W IQT 12.0 ft 80 ft heat/mot 16.5 x 120 ft 198.0 R Ty Conj&,=on number U-value (EhuWF) or FrTM (BWMP) Area Vv) or Perimeter (ft) Load (BWh) Area On or perimeter (ft) Load (BUIr) Heat Cod Gross NIPIS Heat Cod Grose NIRS Heat Cod 6 11 W -'_._ ,L_G W G D W " . L G G D P D _ Y344ors'- _. ---_� __ 4AS-2. - 1344as 4AS-2w 11DO 134-4ors. 4A5.2. 4AS2ry 11DO 12CUsv 11DO ---- _ -_-._. -0.149 0350 0.143 0.350 0.390 0.143 0350 o350 0390 --,— � 0091 0390 - __n_ '� n a a a _ a s w w .M - n ..r.- 356 872 156 3.56 8.72 9.71 356 8.72 8.72 9.71 -.�--__._ 227 9.71 _-_- 2.80 _ 10.15 28.92 280 20.07 7.82 . _ -_2g0 1031' 264. 15 132 30 20 •.'_' qOq . 15 — 296 45 18 - 304 18 -"_.._-249 0 82 14 20 3gg 13 - 233 0 18 —288 18 �- _ `887 ^. 131 292 231 195 - 1385 Y 131 . .. gap 392 174 `�'-648 174 - 698 _ 152 • 229 602 157 �. 1088 _ 155 ..• GS1 1289 214 _ - 413 140 _..___. 0 0 0 0 0 96 - 0 0 0 �`v0 0 - 0 __.- 0 ___ 0 0 0 '� 96 0 0 0 _- 0 0 - 198 0' _ _, 0 .. _._ 0 0 0 342 0 0 0 _`.—..0 0 —' 158 353 ..-..____g _ _.. 0 0 0 0 ' - 268 - 0 0 0 28.65 11.99 ._.`J^1:44 7.82 - .g 0 344 . 0 C -F-- 16B-30ad 0.032 1.180 0.80 29.38 1.74 1422 1 � 1422 1422 137 1133 ' 4025 2469 198 "22hcpm 0.00 0 198 12 6 c)AED amuaon 355 -56 Emelopeloslgan 10658 8610 852 557 12 a) IIftalon b) Room wr0laicn 1609 0 554 0 141 0 48 0 13 Internal gars Cm1pan6@ 230 Apoianosbther 5 1150 3400 0 0 1200 Subtotal(lines6:o13) 12286 13714 993 1805 14 15 LesseAernal load Lessbarder RedsWbulon Subow Dudloads 11% 205/ 0 0 0 12256 1 0 0 0 13714 11% 205A 0 0 125 1118 118 0 0 227 2032 400 Total roam load Arrequired(dm) 13562 0 16412 740 I 1236 0F2: Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ Wrightsoft^ 2021-Feb-0115.19.23 Page 1 ACCN ...arkAe17202Deer ParkAe-1449BRHG-SM Cak=M)8 Front DoorrareeS wrightsoft Right-JO Worksheet Job: 7202 Deer Park Ave -1449 BRHG-S House Date: 07)23)20 By: ww One Stop Cooling and Heating 7225 Sand- Court Wnter Park FL 32792 Phow: (407) 629 - 6920 Fax(407)629-9307 VWb:w OmSlopCaolingmmUmnae:CPC1817652 1 2 3 4 5 Room name Exposedwall Room height Room dmens.ons 1 Room area BED 29.5 it 8.0 ft heaVood 1.0 x 145.5 0 1455 fF MBFD 27.0 R 8.0 8 heaftd 14.5 x 125 It 181.3 IF Ty Construction number U-1. (Btirhire--F) or HTM (BWhff) Area W) or perimeter (p Load (BWh) Area VF) or perimeter (M Load (Bofl) Heat Cod troy MRS Heat Cod Cross )4IPIS Heat Cod 6 11 .W_..._ . G W G D W - ��- G W G D _P.e_.i2C-0 . L-D _7_, _.__ - 4A-2ov 73A4o¢ 4AS2ov 11DO Y3A�400 - 4A5.2. 13440rs 4A5.2ov 11DO 11DO 0�143 0350 0.143 0.350 0390 . _ -0.143 0.350 'n n- a a a "s" s w w w ._ n --- _ 3.56 8.72 3.56 8.72 9,71 '-'356 8.72 356 8.72 9.71 -227 9.71 `-'"-__280 - 10.15 280 2(1.07 7.82 -2.80 -10,31 2.80 28.65 11.99 _.--1.44 7,82 _.._----- 28 0' 96 30 0 '��" 112 - 0 0 0 0 ..__.-.�_.0 0 28' 0 66 14 0 112 0 0 0 0 _---0 0 _ 100 0 235 261 0 -- _ 399 0 0 0 0 _.__-0 0 .-"-__.78 0 185 602 0 _ -----6 ' `^ 313 0 0 0 0 _-_0 0 _ .-.___.100 6 0 0 0 _ _ - _ ` 0 0 116 15 0 _-_0 - 0 � 100 0 0 0 0 - 356 0 0 0 0 _._. _. -----0 0 0 360 131 0 __n-0 0 ---� - 144 - 793 280 0 0 0 0 r __ -' 0. 0 232 430 0 _-_0 0 -- 315 -'-'-0 .__._,__... 0 0 101 0 0 ________0 0 0.143 0.350 0.390 ...__ 0.091 0390 0.032 C 16&30atl 0.80 1.74 146 146 116 253 - -� 181 181 - 27 F� 22A-cym 1.100 �- 29.38 0.00 -146 - 30 867 0 181 6 c)AED-don -37 185 Erndope lydgan 1978 1394 1784 1492 12 a) Irfibaton b) Roarnwitlaton 346 0 119 0 317 0 109 0 13 Internal grins Coagarda@ 230 Appianrssbther 1 230 0 2 460 0 Subtotal (lines6to 13) 2324 1743 2101 2061 14 15 Lesseieernal load L-Irarsfer ReddhbuEm Subtotal Dudloads 11% 20% 0 0 313 2637 279 0 0 360 2103 414 11% 20-A 0 0 0 2101 222 0 0 0 2061 406 Total room load A)rregdred(dm) 2918 0 2517 113 2323 0 2466 111 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -rk 2021-Feb-0115:1923 ,,, -„",� Right-Suile®Uni-1201919.020 RSL123249 Paget AC� .ark Ae17202Deer ParkA.e-14498RFIG-Saul Cale=MIB Front Doorfow&S -�+wrightsoft Right-J®Worksheet Job: 7202 Doer Park Ave -1449 B FM -S House Data: 07/23/20 By. Ww One Stop Cooling and Heating 7225 Sandsmve Court, Wnter Park. FL 32792 Phone: (407) 629- 6920Fac(407)629-9307 Vkb:—OmSbpCaoling.-r License:CPC1817652 1 2 3 4 5 Room name Evorsedwall Room height Room dmemors Room area 0 a 80 ft heaV000l 3.5 x 35 a 12.3 ft MaA 60 ft &0 ft heat/cool 14.5 x 6.0 ft 87.0 f8 Ty construct number LLvalue (Buh4P-°9 Q HTM (BNhM Area OF) or perimeter (ft) Load (BWh) Area (IF) or penmeter (ft) Load (Buh) Heat Cod Crow NIPS Heat Cod Gros NIPS Heat Cod 6VIV 11 V - G W G D .W ..__ L G G D _Pu_ D _. ____ ___._. ___'--"-0.143 13A4as --n 4P5-2ov 13144ow 4A5.2ov 11DO 1344as _._- 4AS2ov 13A4os 4AS2w 1100 .12C-0sv inn 0350 0.143 035D 0.390 .--0.143` 0.350 0.143 0.350 03W --- _-:-0.091 0.390 __ n a a a s s w w w _..._. n __. 3.56 8.72 3.56 8.72 9.71 __.__3.561 8.72 3.56 672 9.71 .__.227 971 _�_.280 10.15 2.80 20.07 7.82 2.80--. ` 1031 J ._ T. -__._0 .0 0 0 0 .0. 0 6 0 0 .___.___0 0 .__.__. . 0 0 0 0 0 __._0._.--__.0_�_._._. 0 6 0 0 .__r.TO_.-0 0 _0 0 0 0 0 0 0 0 0 0 _._ ._, __, 0 0 0 0 0 0 q _�.. 6 0 0 . 48 0 0 0 0 __O 0 0 0 0 0 0 __. 48 0 0 0 0 0 -'---'0 0 0 _..._.. _. —0.� 0 -- �- __-. -� 171 0 0 0 0 0 00 0 0 _._ 0 0 _- ------ 134 0 0 0 0 0 0 0 0 280 2865 11.99 -.: .__1.-44 7.82 _�.._0 0 C �F~ 16&37ad --_�- -- 0.032 �- 0.80 29.38 _-1.74 —0.00 -�--U - 12 10 21 87 87 -- —6 69 176 151 2b4cFn 1.180 12 ----0 --0 0 87 .-0 6 c)AEDe ,don Erxdopelawgan 10 21 417 276 12 a) Irdltralon b) Roorowntlaton 0 0 0 0 70 0 24 0 13 Irdemelgdns Doapens@ 230 Ajplon-Atner 0 0 0 0 0 0 Sutiotd(lines66113) 10 21 487 300 14 15 Lesel4-al load Lesstranskr Reddribullon SUMotal Dudloads 119% 20°h 0 0 -10 0 0 0 0 -21 0 0 1111, 20°k 0 0 2 489 52 0 0 86 386 76 Total room load Air required(dm) 0 0 0 0 541 0 462 21 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. w_rigt7YSoft" 2021.Feb-0115:1923 _ ,,, .� �,,,,-. Id9ht-Suite®Urvversa1201919.029 RS1R3249 Pa9e3 �CCA ...ark Ae17202 Deer ParkAe-1449 B RHG-Snit Cale=MIS From Doorfares: S wrightsoft Right-JOWorksheet Job: 7202Deer Park Ave -1449BRHG-s House Date: 07/23120 By: WIN One Stop Cooling and Heating 7225 Sanbseow Court Wnter Park FL 32792 Phone: (407)629-6920E-(407)629-9307 6tbb:-O.$ZpCooling.-Li.s.:COC1817652 1 2 3 4 5 Room name Exposedwall Room height Room dmensons Room area Mwc 45 It 80 It heaVowl 4.5 x 9.0 ft 40.5 IF LAUN 0 It 8.0 It heaVmol 6.0 x 3.0 ft 18.0 11 Ty Construdon number U-value (RWhAF-°F) Or HTM (BUhAM Area (IF) or perimeter (a) Load I Area In or perimeter (ft) Load Mth) Heat Cod Gras NrPS Heat Cod Gross NrPS Heat Cod 6 11 WII `G W G D W�-- � G G D PV.. �D _13A-4oe _ 40S2ov .- 13A4as 4AS2ov 11D0 1344oa - 4A5-2ov 4AS2w 11DO 12C-0sv �..�. 11D0 _- _0:143 0.350 0.143 0.350 0.390 0.143 0.350 0.3X 0.390 0091 0390 n _._ n a a a s s w w _ _ n �-. -_ 3.56 8.72 3.56 872 9.71 3.56 - Ith A3.56 8.72 9.71 227 9.71 _� -----280 2.80 - 10.15 2.80 2007 T82 __ 28l) 10.31 280 28.65 1199 d_-.1:44 782 " 0. 0 0 0 0 _ 0 ..._ _.35 0 0 .. 0 - 0 _ 0 0 0 0 _ 0_�..0 _ 0 35 0 0 0 0 0 0 0 0 . L. 0 _ ~128 0 0 0 0 - 0 0 0 0 � 0 _y - 0 101 0 0 __.0 - '0 0 0 0 0 0 _y.4 0 .� __0 0 0 _._.._._.._.p 0 -Y.-- 18 ._.T_1B 0 0 0 0 0 y, 0 _,_ ._0 0 0 __. 0 0 0 0 0 . _ f0 0 _ .. _ �_0 0 0 0 0 0 0 -- -0 _ _ 0 �.0 0 0 --0 0 31 0._._ 0 18 0'' 0 ib-�-- __-�- C 16B30ad-�- 0.032 0.80 -= 29.38 _ 1.74 -000 41 41 32 `-��132 70 F 22A-cpn 1:180 � .-.---.41 -5 ---0- 6 c)AEDe-raon -6 -16 EmdcpelosVgan 293 165 14 15 12 a) IrAIbalcn b) Room rehtlawh 53 0 18 0 0 0 0 0 13 Internal gars ompa,te@ 230 Appliana:sblher 0 0 0 0 0 500 Subtotal (lines6lo 13) 346 183 14 515 14 15 Lme&ma load L mtrarder RedsOlblon Subtotal Dudloads 11% 20GA 0 0 0 346 35 0 0 0 183 36 11% 20% 0 0 -14 0 0 0 0 -515 0 0 Tod room load _ Ar requlred(dm) I. 382 0 220 10 0 0 0 0 Calculations approved byACCA to meet all requirements of Manual J 81h Ed. W`r�g�ltSOft- 2021.Feb-01 15:1923 _ R9hl-SuiteOUN.-1201919.020RSLr23249 Page ii:�.CA ..arkAe17202Daer ParkA•e-1449BRHG-SPA Cale-M78 Front Deorfaces S - wrightsoft Right-J® Worksheet House One Stop Cooling and Heating 7225 Send- Court WnWr Park FL32792 Phone:(407)629-6920 Fax(407)629-9307 Web:xwx.OmSbpCoolingmmUmnw:CAC1817652 Job: 7202 Deer Park A- -1449 B RHG -S Date: 07123120 By: WIN 1 2 3 4 5 Room reme Fnedwall Room height Roomdmeraom Room area BA2 0 H 80 ft heatlood 60 x 9.0 ft 54.0 ft BFD2 11.0 ft 8.0 ft heWcool 1.0 x 135.0 ft 135.0 a, Ty Cor,stud. number U-value (BWNft'-°9 or HTM (BWhlft7 Area (ft) w perimeter (ft) Load (BWh) Area '(ft) or pen -ter (T Load (BbA1) Heat Cod Gras NIPS Heat Cod Goss NIPS Heel Cod g 11 -yy-___ _L-G W - G D G VL13A-0os G D _P L-D F _1344oa _ .�_. 4A5-2w _�-..__,__ 13A-4as 4A5.2w 1100 4A5.2w 4A52w 11DO -12C49' 7- 11DO -16B-3Dad --- _0.143 _ 0.350 0.143 0350 0.390 '0350 0.143 0350 0390 - -._0091 0390 -__ 0.02d _-n._ n .- e - a a s - w..._ w w n 3.56 8.72' _ 3.56 8.72 9.71 8.72 3.56 8.72 9.71 --227 9.71 0.80 2938 __.__- 280 10.15 _.Z� 20.07 7.82 -10.31 2�0 2BBS 11.99 -�1.44 7.82 ____-1.74 W0_ 00 0 .0. ...._ 0 0 0 _ � - 0 0 0 _0 __ -_ 0 __ _-O 0 0 0 _0_ 0 0 0 0 -.--50 ___,w_0 0 .___ 0 __ _.o 0 0 0 0 -._`. 0 - - "0 0 0 0 0 _ _- _ .: _ _ _ 0 0 0 __--_ --'._0 0 _ ---a ---_U ._--- _ _;gg _. 15 - 0 0 0 --- 0 _ 0 0 0 0 88 0 -- 135 -----135 _ . 73 0131 ^ 0 0 0 _ `�0 _ 0 0 0 0 �__88 0 135 _ _ 26D 0 0 0 0 - ___._..o 0 0 0 0 106 �-_32:i _. 204 _ 152 0 0 0 _ __ _ � (y _�_.__0 0 0 0 0 234 --0 - �. O 0 0 ^'--"-0 0 --'--'-43- D 0 54 '-'_F__� __ 224cpn 1.180 0 T 11 6 c)AFD exauaon -3 -30 Emdopeloslgain 43 91 1021 68B 12 a) IrA*Acn b) RoomveWaEon 0 0 0 0 129 0 44 0 13 Imemal gars Doapm@ 230 Applianoesbther 0 0 0 1 230 0 8ubtotal(lines6b13) 43 91 1150 962 14 15 LesseNemaload L-1-der Redstnbulon &btow Dudloads 11% 20-A 0 0 171 214 23 0 0 367 457 90 11% 20-A 0 0 102 1252 132 0 0 123 1085 214 Taal room load Air regdred(dm) 237 0 548 25 1384 0 1299 59 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ - wrightsoTt^ 2021-Feb-01151923 ,-,�, Right-Suile�Uniue-1201919.020 RSU23249 Page ACiA ...arkM47202Deer Park;: 1449BRHG-Snit Carc=MI8 Front Doorfa-S - ' wrightsoft Right-M Worksheet Job: 7202Deer Park Ave -1449BRHG-s House Date: 07123/20 ww One Stop Cooling and Heating 7225 Sand-e Court Wner Park FL32792 Phone: (407) 629 -6920 Fax(407)629-9307 Web:l OneSmpCooling.00m License: CPG7817652 1 2 3 4 5 Room name EV eedwal Room height Room dmenaom Room area BED 105 ft 8.0 ft heatlood 1D x 136.5 ft 136.5 R FOY 4.5 ft 6.0 ft he9V0nl 1.0 x 139.8 ft 139.8 fF Ty Corumudon nnriber U-value (BWhA'-°F) Or HTM (Buff) Area W) or perimeer (ft) Load (BWh) Area (R') or perimeter (M Load (BM) Heat Cool Goss NP/S Heat Cod Goss NIPS Heat Cod 6 1 1 .. W .__`" .�G W G D W G _W-'aAA- G D .P ._..- L�D _ .____ 13A4b6 "- 4A5.2w .' 73q-4ors 4A5-2ov 11D0 13A-4ors - 4A5-21v - 4Ai2w 11D0 12C-0Zv 11OD 0.143 0" 0.143 0.350 0.390 0.143 0.350 0.143 0.350 0390 -`-O.D91 0.390 ._.._.._-. �n n a a a s s r w w --....,._....227 n 3.56 8.72 3.58 8.72 9.71 3.56 '8.72 3.55 8.72 9.71 9.71 "�280 10.15 280 2007 7.82 _ -2_60 10.31 28D 2865 11.99 t:d4 7.82 __ -��.- 0 _. _._0 0 0 0 - 84 -: .15 T 0 0 0 �• 0 _._ -� ..0 ...• - 0 0 0 0 ^-69 .. 13 0 0 0 0 137 _.Y __. 0 0 0 0 0 -'-246 131 0 0 0 - 0 .__. _._._ - 0 0_0 0 0 0 V 193 -__...._155 T 0 0 0 -.-_~ D '0 - .-.__ .� - 0 ' % 0 20 ----'-0 0 T� 0 0 0 J 216 i8 ..�._.__ -0 0 __0 16 0 20 ' "-� 0 0 0 0 '0 'V 196 18 --�- 0 0 57 0 195 0 0 0 0 --_449 174 -----o 0 0 44 0 157 0 -� 0 0 0 _.•._.-_286 140 C 16&30ad 0.032 1_.180 ��-- _ O86 -29_-.38 1.74 --_0D 737 137 109 � 309 �� 237 140 140 111 � 132 243 _ FT 7_-c_pm__-_ -_ . 11 0 740 _ 5 0 6 o)AED a-rsion -22 41 Emdcpeloselon 794 563 1118 828 12 a) IMItralon b) RoornwrNla4on 123 0 42 0 53 0 18 0 13 Internal gars Covpan5@ 230 AR{ianomkowi 1 230 300 0 0 500 SWtDtal (lines6to 13) 917 1135 1171 1346 14 15 Leeee1¢ernaload Les t-der RedstibLdw &btetzl Dudloads 11% 20% 0 0 476 1393 147 0 0 548 1683 331 11% 20% 0 0 .1171 0 0 0 0 .1346 0 0 Torn room load Air requred(dm) F-1 541 0 2014 91 0 0 0 0 Calcvlabons approved byACCA to meet all requirements of Manual 18th Ed. -fjWrlgtl>tSO ` 2021-R60115:19.23 Right.SWeOLhwm[201919020RSL23249 Pop . AM2202 Deer ParkM-1449 B RHG-SM Cale =NUB Front Deer hoes S wrightsoft Right -A) Worksheet House One Stop Cooling and Heating 7225Sand�CourtWd rPark FL32792Pt ne:(407)629-6920Fac(407)629-9307 Vt§b:w OmSmpCmling.mmUmnse:CAC1817652 Job: 7202 Deer Park Ave -1449 B RHG -S Data: 0712312D aY ww 1 2 3 4 5 Room name Fvedwdl Room height Room dmensons Raom area LN 320 R 8.0 ft heaVmd 1.0 x 274.5 R 2745 IF Ty Corl&udon number U-value (Bb ff-T) or HTM (BbMF) Al- (IFI or perimeter (ft) Load (Bbh) Area or pedmetsr Loaf Heat Cod Gras NIPS Heat Cod Gross NIPSS Heat Cod 6 11 .w ___._ .L—G W G D G W G D L— D 4AS-2o 1344au5 4A5-2ov 11D0 4AS2w 13A-0o¢ 4AS2w 11DO 11D0 0.143 - 0350 0.143 0.350 0.390 0350 0.143 0.350 0.390 : ------0.091 0.390 'n " n a a a s w w w _......_ n 3.56 - 8.72 3.56 B72 9.71 `8.72 3S6 8.72 9.71 ".�.227 9.71 .—.:__2180._-0 _ 10.15 280 20.07 T82 7031 280 2B.65 11.99 "-`1.44 7.82 .^.`.;. 0 0 0 .._�_. - 0 144 30 18 .._....- .— .._.�. 0 0- — 0 -- 0 0 0 0 ." 112 - 0 98 0 18 —_6�_..__.--d 0 0 - 0 0 0 0 . _._._399 .. 0 342 261 174 0 0 0 0 0 0 — —313 0 269 a60 214 �_.___._ 0 0 —477 �� ..__ _ ----- " . _16B-30ad "-- - 0,032 V080 2938 174 —0.00 275 .' .275 275 .--. 32 219 F ?24+yrn 1.180 'T— 6 o)AED e>ralrson 389 ErNdopela.Von 2335 2521 12 a) Irthralon b) Roamv Malon 376 0 129 0 13 hernal gains: 230 Apldlanoesb#t 0 0 9w Sabtohl (II-610 13) 2711 3550 14 15 L—demalload LmVarsfer Redstibaon Subtotal Dudloads 11% 2MA 0 0 5 2716 287 0 0 172 3722 732 FtrT oad (dm) 3002 0 4454 201 Calaflabons approved byACCA to meet all requirements of Manual J 8th Ed. _ wrightsoft^ 2021-Feb.0115:1923 r _ _ Right-SuikSUdtersa1201919.020 RSU23249 Pagel /�� ...arkAe17202 Me, ParkM-1449 8 RHG-SM Calc=NUB Front Coo, bms S Static Pressure and Friction Rate Job: 7202 Deer Park Ave -1449 BRHG-5 -�- wrightsofto Date: 07123120 House W. vevv One Stop Cooling and Heating 7225Sand—. Cour(NMler Park FL32792Phona:(407(629-692DF-(407)629.9307 Web:—O-StopCoo11ng-.U.nm:CPC1817652 Project For. CENTURY COMPLETE 7202 DEER PARK AVE, FL Available Static Pressure Heating Cooling (in H2O) (in H2O) E)demal static pressure 0 0.50 Pressure losses Coil 0 0 Heatexchanger 0 0 Supply diffusers 0.03 0.03 Retum grilles 0.03 0.03 Filter 0.10 0.10 Humidifier 0 0 Balancing damper 0 0 Otherdevice 0 0 Available static pressure -0.2 0.34 Total Supply Return (it) 01) Measured length of run -out 18 0 Measured length oftrunk 8 0 Equivalent length offittings 105 0 Total length 131 0 Total effective length 131 Heating Cooling (in/100ft) (in/100ft) Supply Duds -0.122 <0.06 0.260 > 0.18 Return Duds -0.122 <0.06 0.260 > 0.18 Fitting Equivalent LengthDetails Supply 1 1A=20,4X=35, 11 G=5, 11 G=5, 1 A=35, 11 G=5: TotalEL=105 Return TotalEL=0 2021-Feb-01 15:19:23 wrightsofte Right-Suue®Unheraal 201919020 RSUZ3249 �1^/1+�.A nwr.arxwomx,o+.n�x.w Page 1 ACM ..arkAe\72020eer ParkFse-1449BRHD-Saul Cak=M78 Frant Door faces S Duct System Summary Job: 7202 Deer Park Ave -1449 BRHG-S wrightso�yl Le Date: 07/23120 House Br ww One Stop Cooling and Heating 7225 Sands CautWnler Park FL32792 Phone: (407) 629 - 6920 Fax(407)629-9307 web:w OmSbpCoolingmmUmw :CPG1817652 For: CENTURY COMPLETE 7202 DEER PARK AVE, FL Heating Cooling Extemal static pressure 0 in H2O 0.50 in H2O Pressurelosses 0.16 in H2O 0.16 in H2O Available static pressure -0.2 in H2O 0.34 in H2O Supply/return available pressure -0.080 /-0.080 in H2O 0.17010.170 in H2O Lowest fiction rate -0.12 iN100ft 0.260 in/100ft Actual airflow, 0 cfmI 740 dm Total effective length (TEL) 131 it Name Design (Btuh) Htg (cftn) Cig (dm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BA2 c 548 0 25 0.321 4.0 Ox 0 VIFx 10.8 95.0 st2 BE02 c 1299 0 59 0.284 6.0 Ox 0 VIFx 24.7 95.0 st1 BEDS c 2014 0 91 0.294 6.0 Ox 0 VIFx 15.7 100.0 st2 BE04 c 2517 0 113 0.260 6.0 Ox 0 VIFx 26.0 105.0 st2 Krr c 2432 0 110 0.309 6.0 Ox 0 VIFx 15.0 95.0 st2 LN c 4454 0 201 0.277 7.0 Ox 0 VIFx 27.5 95.0 st1 NSA c 462 0 21 0.292 4.0 Ox 0 VIFx 16A 100.0 st1 LASED c 2466 0 111 0.303 6.0 Ox 0 VIFx 17.1 95.0 stl MMc c 220 0 10 0.302 4.0 Ox 0 VIFx 17.7 95.0 st1 Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (dm) (dm) FR (fpm) (in) (in) Material Trunk st1 PeakAVF 0 401 0.277 511 12.0 0 x 0 VinlFlx st2 PeakAVF 0 339 0.260 621 10.0 0 x 0 VinIFIX Return Branch Detail Table Name Grille Size(in) Htg (dm) Clg (dm) TEL (it) Design FR Veloc (fpm) Diam (in) HxW (in) Stud/Joist Opening (in) Duct Mail Trunk rbt Ox 0 0 740 0 0 0 0 Ox 0 VIFx wri htsoft, 2D21-Feb-011519:23 9 Right.Suite®l rdeerea1201919.020 RSU23249 Page 1 a wih• f Bnh84v W C+may Ca.pr 9 ACa _arkAe17202 Deer ParkAe-1449B RR* -SPA Cal, =MIB Front Door fares S Level 1 LM T8.4 MBED 10x6 10x8 4- 'SRB 2, 110 cfm 202 cfm 24 x 4 7" 6" 4" Bath Dud to Roof 4" Dryer Dud to Roof KIT 20 cfm W/Fan Cap wlDryerVent Box LAUN Broan 50CFM BA2 6' MBA pxg 1�1 cfm 12 BED 4" Bath Dud to Roof W/Fan Broan 50CFM 6 " 8 4 fm 10 " 59 cfm 4" SRB 1' T 740 cfm 10x6 6 - 6 ' 24x14 RA _ 92 cfmle 24 x 4 2.0 ton W/5KW @240V 1 PH Jul A/C-1: 2.0 TON 14X14 Plan 14.0 SEER H:P. BED 3 24 x 4 ON METAL STAND AC Slab By Builder 2' From Wall 10x6 112 cfm 4 24x4 FOY GAR Job #: 7202 Deer ParkAve -1449 B RHG -S One Stop Cooling and Heating Scale:1 : 73 Performed by VWU for: Page 1 CENTURY COMPLETE 7225 Sandsoove Court Right -Suite® Universal2019 7202 DEER PARK AVE Winter Park, FL 32792 19.020 RSU23249 FL Phone: (407) 629 - 6920 Fax (407) 629 - 9307 2021-Feb-01 15:13.30 wwwOneStopCooling.com er ParkAve - 1449 B RHG-SnA