Loading...
HomeMy WebLinkAboutInstallation Instruction; Model 1101 V Series All Steel Foundation System Pan & Concrete- I OLIVER TECHNOLOGIES, INC. INSTALLATION INSTRUCTIONS FOR FLORIDA MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM PAN. & CONCRETE (revision 5/1 R) PATENT# 6634150 & OTHER PATENT PENDING ,IREVItED By SEANS4�MGER at s�2 em, 8E3ilifi RrEv"iEWED By SEAN S WONGER:at-6:33 tom, 8/31/18 Tile, Copy t REVIEWED r CODE COMPLIANCE ST. LUCIE COUNTY SOCC t°;i l9 it: g,dd � de A • f3i O► V_ en ° STATE OFOR • �''� • o f �6Q't �s s�eas6sti Atg-24, a0ts K 467 Swan Ave r Hohenwald, TN 38462 • (800) 284-7437 • www.olivertechnologies.com • Fax (931) 796-881 1 OLIVER TECHNOLOGIES, INC. FLORIDA INSTALLATION INSTRUCTIONS FOR THE MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM MODEL 1101"V" (Steps 1-1+4) LONGITUDINAL ONLY: Follow Steps 1-9 LATERAL ONLY: Follow Steps 1-3 and Stepss10-14 ENGINEERS STAMP FOR CONCRETE APPLICATIONS: Follow Steps 15-18 ENGINEERS STAMP 1. SPECIAL CIRCUMSTANCES: tf the fallowing conditions occur - STOPI Contact Oliver Technologies dt 1-800-384-7437. a) Pier height exceeds 48" c) Roof eaves exceed 16" e) Location is within 1500 feet of coast b) length of home exceeds 76' d) Sidewail height exceed 96" ►NSIALLATION OF GROUND PAN, 2. Remove weeds and debris in an approximate two foot square to expose firm_soil for each ground pan {C) 3. Place ground pan (C) directly below chassis 1-beam. Press or drive pan firmly into soil until flush or belovr soil then install pier per t manufacturers instructions or per Florida Regs. 't SPECIAL NOTE: The longitudinal "V" brace sys#em may also serve as a pier underthe home and Should be loaded as any other pier. It is recommended that after leveling piers, and one-third inch (1/3") before home islowered completely on to piers, complete steps 4 through 9 below then remove jacks. INSTALLATION OF LONGITUDINAL "V" BRACE SYSTEM (Modell 101 L "V") NOTE: WHEN INSTALLING THE LONGITUDINAL SYSTEM ONLY, A MINIMUM OF 2 SYSTEMS PER FLOOR 5ECTIWQN 15 REQUIRED. SOILTEST PROBE SHOULD BE „ USED TO DETERMINE CORRECTTYPE OF ANCHOR PER SOIL CLASSIFICATION. IF PROBETEST READINGS ARE BETWEEN 175 & 275 A 5 FOOT ANCHOR MUST BE USED. IF PROBETEST READINGS ARE BETWEEN 276 & 350 A 4 FOOT ANCHOR MAY BE USED. USE GROUND ANCHORS WITH DIAGONALTIES AND STABILIZER PLATES EVERY 5'4" . VERTICALTIES ARE ALSO REQUIRED ON HOMES SUPPLIED WITH 1(ERTICALTIE CONNECTION POINTS (PER FLORIDA REG.). 4. Choose one of the approved longitudinal tube installations; either Diagram'A or B.Then select the correct square tube (E) length from the diagram for appropriate pier height at support location or cut and=driil 1'5"square tube to achieve appropriate length. PIER HEIGHT 1.25" 1.50 PIER HEIGHT 1,50" (40" Min. - 45° Max.) Tube Length Tube Length g/t6 pia i.S62"j hale (40` Min. - GO' Max.) Tube Length 0 75" 7 3/4" to 25" 22" . 18" .- 24 3/4" to 321 /4" 32" 18+ 33" to 41" 44" 40" to 413" 54" 14' to .18" Z0" 18" to 25" 2811 24" to 35" 39" 301 to 40" ' 11 36" to 48" 54" Diagram A Diagram B 5. install (2) of the 1.50" square tubes (E) int the "U"+bracket (1), insert carriage bolt and leave nut }Dose for final adjustment. 6. Place 1-beam connector (F) loosely on thejbottom flange of the I-beam. . 7. (For Diagram A installation) Slide the selected 1,25" tube (E) into a 1.50" tube (E) and attach to I-beam connectors (F) and fasten loosely with bolt and nut. (For Diagram 9 installation) Attach the selected 1.5"tubes (E) to the I-beam connectors (F) and fasten loosely with bolts and nuts. S. Repeat steps 6 through 7 to create the "V" pattern of the square tubes loosely in place. 9. Using standard hand tools tighten all nuts and bolts. (For Diagram A installation only, secure 1.25" and 1 .50" tubes using four(4) 1 /4"-14 x 3/4' self -tapping screws in pre -drilled holes.) ItISTAI.LATION OF LATERAL TELESCOPING TRANSVERSE ARM SYSTEM (Model 1101 T 'IV") THE MODEL 1101 "V" (LONGITUDINAL & LATERAL PROTECTION) ELIMINATES THE NEED FOR STABILIZER PLATES & FRAMETIES. NOTE:THE USE OF THIS SYSTEM REQUIRES VERTICALTIES SPACED AT 54". FOUR FOOT (4') GROUND ANCHOR MAY BE USED EXCEPT INHERE THE HOME MANUFACTURER SPECIFIES DIFFERENT. 10. Install remaining vertical tie -down straps and'4' ground anchors per home manufacturer's instructions. NOTE: Centerline anchors to be sized according to soil torque condition. Any manufacturer's specifications for sidewall anchor loads in excess of 4,000 lbs. require a Y anchor per Florida Code. 11. Select the correct square tube brace (H) length for set-up lateral transverse at support location. The lengths come in either 60" or 72" lengths, (With the 1.50" tube as the bottom tube, and the 1.25" tube as the inserted tube.) 12. Install the 1.50 transverse brace (H) to the ground pan connector (D) with bolt and nut, 13. Slide 1.25" transverse brace into the 1.50" brace and attach to adjacent I-beam connector (1) with bolt and nut. 14. Secure 1.50" transverse arm.to 1.25" transverse arm using four (4)1 X' - 14 x 31N' self -tapping screws in pre -drilled holes. vision 08 P2�3/1 E PATFNTa AAul r%n A 0THFR AATFNT Pmnwn 18. When using part# 1101 INSTALLATION USING CONCRETE RUNNER/ FOOTER 15. A concrete runner, footer or slab maybe used in place of the steel ground pan. a) The concrete shall be minimum 2500 psi mix b) A concrete runner may be either longitudinal or transverse, and must be a minimum of 8" deep with a minimum width of 16 inches longitudinally or 18 inches transverse to allow proper distance between the concrete bolt and the edge of the concrete (see below). Q Footers must have minimum surface -area of 441 sq. in. (Le. 21 "square), and must be a minimum of 8" deep. d) If a full slab is used, the depth must be a 4" minimum, Special inspection of the system bracket installation is not required. Footers must allow for at least 4" from the concrete bolt to the edge of the concrete. NOTE: The bottom of all footings,, pads, slabs and runners must be per local jurisdiction. LONGITUDINAL• (Model 1101 LC "V") 16, When using Part# 1101-W-CPCA (wetset) simply install the bracket in runner/footer OR When installing in cured concrete use Part# 101-D-CPCA (dryset}.The 1101 (dryset) CA bracket is attached to the concrete using (2) 5/8"x3' concrete wedge.bolts (Simpson part # S162300H 5/8" X 3" or Powers equivalent). Place the CA bracket in desired location. Mark bolt holey locations, then using a 5/8" diameter masonry bit, drill a hole to a minimum depth of 3". Make sure all dust and concrete is blown out ofthe holes. Place wedge bolts into drille holes, then place 1101 (dry set) CA bracket onto wedge bolts and start wedge bolt nuts. Takesa hammer and lightly drive the wedge bolts down by hitting the nut (making sure not to hit the top of threads on bolt), The sleeve of concre ,e wedaekbolt needs to be at or below thr tog of concrete. Complete by tightening nuts. LATERAL: (Model 11 of TC HIV'°l 17. For wet set (part # 1101-W TACA) installation simply install the anchor bolt into runner/fdote For dry set installation (part # 1101-D TACA mark bolt hole locations, then using a 5/8" diam. masonry bit, drill a hole to a minimum-80) of 3". Make sure all dust and concrete is blown out of the hole. Place wedge bolts (Simpson part #5162300H 5/8" X 3" or Powers into (D) concrete dry transverse connector and into drilled hole. If needed, take a hammer and lightly.;deiy the wedge bolts down, by hitting the nut_(making sure not to hit the top of threads on bolt), then remove the n CVW (wetset) or 1101 CVD (dryset), install .persteps 7& 18. Notes: 1. LENGTH. OF HOUSE IS THE.ACTUAL BOX SIZE LOCATION OF TRANS VERSERACING ONLY 3 I:. = LOCATION OF LONGII'UDINA ":BRACING ONLY 4.. ; =TRANSVERSE AN LONGITUDINAL LOCATIONS AND LENGTHS UPTO52' I t � 1 �1 �Ti i+ ALL WIDTHS AND LENGTHS OVER 52'TO 80" i HOMES WITH 5/12 ROOF PITCH REQUIRE: PER FLORIDA REGULATIONS 6 systems for home lengths up to 52' and 8 systems for homes over 52' and up 80'' PATENT# 66341 SO & OTHER PATENT RENDING Page 2 Revision 08/23/1E I -Transverse Arm, "earn Connector D - Pan Transverse H -Transverse Arm `Top (1.25') Bottom (1.5 i C - Grovnd Pan I -Transverse Arm. t-Seam Connector Part 4 1 i01 0 -TACA H -Transverse Arm Part x 1101- W -TACA not shown �Top (1.251 Bottom'0.5`) I Cement Block i _ CMU omitted t ^�/� Omitted 1 LFor Clarity J D - Concrete Transwofs For Clarity I J y Connector 1 C-Concrete Slab; R 72 W Max. Footer " Baits Model # 1101 T " V" Model # 1101 TC "W' Florida approved 4' ground anchors may he used in all locations except where home manufacturers spettficabons for sidewall straps are in excess of 4,000 Ibs.These locations require a 5' anchor. Per Florida code. z. C = GROUND PAN / CONCRETE FOOTER OR RUNNER i�. D = GROUND PAN / CONCRETE U BRACKETS TRANSVERSE CONNECTOR (connects with grade 5!-1 /2r x:3 112" carriage bolt and nut) E = TELESCOPING V BRACE TUBE ASSEMBLY 0.5" TUBE BOTTOM AND 1.25" TUBE INSERTy OR i 5," TUBE _ "V" BRACE 1-BEAM CONNECTOR ASSEMBLY _ H = TELESCOPING TRANSVERSE ARM ASSEMBLY I =TRANSVERSE ARM I -BEAM CONNECTOR (connects with grade 5 112":x 2" 112" carriage bolt and nut) =V PAN BRACKET (connects with grade 5 -1/2"x 2" 1/2"carriage bolt and nut) I -Transverse Arm, I -Beam - Pan Transverse Connector f Concrete TransverseBracket E - "V" Brace Tube (1.5") Model # 1101 "v,r PATENT# 6634150 & OTHER PATENT PENDING Part.' 1101 D-CPCA � Part if 1102 V)-CP£A not she own model # 110,1 C "V" Revision 08/23/1 E