HomeMy WebLinkAboutResidential Heat Loss and Heat Gain CalculationM 2 Copy
Page 1 Residential Heat Loss and Heat Gain Calculation 8/13/201.8
In accordance with ACCA Manual J
Report Prepared By:
Central Air Systems Inc.
For:
Design Conditions:. West Pam Beach
Indoor:
Summer temperature: 70
Winter temperature: 70
Relative humidity: 55
Outdoor:
Summer temperature: 90
Winter temperature: 42
Summer grains of moisture: 127
Daily temperature range: Medium
Building Component
Sensible
Gain
(BTUH)
Latent
Gain
(BTUH)
Total
Heat Gain
(BTUH)
Total
Heat Loss
(BTUH)
Duct
711
01
711
719
Floors
1,048
0
1,048
` 1,864
Walls
1,376
0
1,376
11632
Ceilings
1,977
0
1,977
1,538
People
1,200
020
2,120
0
Fireplaces
0
0
0
0
Mise
1,200
0
1,200
0
Windows
4,317
0
4,317
11568
Doors
483
0
483
573
Glassdoors
766.
0.
766
891
Skvliahts
0
0
0
0
5,706
Whole House 14,936 4,768 19,704 15,090
(1.5 tons )
HVAC-Cale Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101
Load calculations are estimates only, actual loads may vary, due to weather and construction differences.