HomeMy WebLinkAboutResidential Heat Loss and Heat Gain CalculationM 2 Copy Page 1 Residential Heat Loss and Heat Gain Calculation 8/13/201.8 In accordance with ACCA Manual J Report Prepared By: Central Air Systems Inc. For: Design Conditions:. West Pam Beach Indoor: Summer temperature: 70 Winter temperature: 70 Relative humidity: 55 Outdoor: Summer temperature: 90 Winter temperature: 42 Summer grains of moisture: 127 Daily temperature range: Medium Building Component Sensible Gain (BTUH) Latent Gain (BTUH) Total Heat Gain (BTUH) Total Heat Loss (BTUH) Duct 711 01 711 719 Floors 1,048 0 1,048 ` 1,864 Walls 1,376 0 1,376 11632 Ceilings 1,977 0 1,977 1,538 People 1,200 020 2,120 0 Fireplaces 0 0 0 0 Mise 1,200 0 1,200 0 Windows 4,317 0 4,317 11568 Doors 483 0 483 573 Glassdoors 766. 0. 766 891 Skvliahts 0 0 0 0 5,706 Whole House 14,936 4,768 19,704 15,090 (1.5 tons ) HVAC-Cale Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads may vary, due to weather and construction differences.