Loading...
HomeMy WebLinkAbout7005 arthurs revisionPrepared for My Florida Roofing Contractor Project: Single Family Residence Location: 7005 Arthurs Road Fort Pierce, Florida Project ID: Date: 8/2/2021 Ventilation Calculation Edward K Roske This document has been •tit"'tt, electronic ` RY signed and d ,� GEgg seaed 8 , by Edward Roske, PE 2021.08. using a Dlgibl Sf his . �•T� P Mted copies of thk document are nel consldored grAlgp ^/� signed and sealed and di• {0p o_� � too'o4— 09.20•56 on.1suremustpevedfled on rrpAlA� g • anebctronb copes. rr unnu+o�o Calculations by Seaside Engineers Certificate of Authorization No. 32048 4265 60th Court Vero Beach, Florida 32967 (722) 202-8008 info@seasideengineers.com www.seasideetigineers.com Roof Perimeter 307 ft (measured from the roof report) Attic Area 2659 sgft (measured from the roof report) VENTILATION CALCULATION Attic Area 2659 SQFT Ventilation Calculation (50% Intake, 50% Exhaust) Total (Intake and Exhaust) Soffit (Intake) Roof (Exhaust) 1:300 per US FHA (REQUIRED) 8.86 SQFT = 1276.32 5QIN 4.43 SQFT = 638.16 SQIN 4.43 SQFT = 638.16 SQIN 1:150 (RECOMMENDED) 17.73 SQFT = 2552.64 SQIN 8.86 SQFT = 1276.32 SQIN 8.86 SQFT = 1276.32 SQIN Provide exhaust and intake ventilation that meets or exceeds the requirements above Required ventilation per foot of soffit = Diameter core in soffit: Area of core = 2.079 sqin 4 in 12.560 sgin Core required every 6.04 feet in the soffit