Loading...
HomeMy WebLinkAboutSTEEP SLOPE ROOF SYSTEMT LUC E Section D (Steep Slope Roof System) Roof System Manufacturer: Tamko Building products Notice of Acceptance Number: FI # 18355-R6 Minimum Design Wind Pressures, If Applicable (From RAS 127 or Calculations): Zone 1:-38. 1 Zone 2e: -502 Zone 2n: -50.2 Zone 2r: -49.6 Zone 3e: -50.2 Zone 3r: -50.2 Deck Type: 119/32 CDX' Plywood f Roof Slope: Type Underiayment: I Install new tri-built peel & stick 4:12 Insulation; I N/A Fire Barrier: I N/A Rid v VAentifation? Fastener Type & Spacing: 1-1/4" x .120 Coil Nails / 6 nails pattern = 1-2-2-1 Adhesive Type- N/A Type Cap Sheet: N/A Mean Roof Height: 12' Roof Covering: Shingle /Tamko Type & Size Drip 2° x�/Al,-,nurn Edge:. Section C (Low Slope Roof) Fill in specific roof assembly components and identify manufacturer (If a component is not used, identify as "NA") System Manufacturer: POLYGLASS USA Product Approval No.: FL#1654-R27 Design Wind Pressures, From RAS 128 Or Calculations: Zone 1':-36.1 Zone 1: -36.1 Zone 2: -47.7 Zone 3: -64.9 Max. Design Pressure, from the specific product approval system: Peel & stick / SBS-SA Deck: Type: Plywood Gauge Thickness: 19132 CDX Slope: 1/12 Anchor/Base Sheet & No. df Ply(s): N/A Anchor/Base Sheet Fastener/Bonding Material: N/A Insulation Base Layer: NIA Base Insultation Size and Thickness: N/A Base Insulation Fastener/Bonding Material: N/A Top Insulation Layer: NIA Top Insulation Size and Thickness: N/A Top Insulation Fastener/Bonding Material: N/A Base Sheet(s) & No. of Ply(s): 1 Base Sheet Fastener/Bonding Material: SELF -ADHERING Ply Sheet(s)' & No. of Ply(s): N/A Ply Sheet Fastener/Bonding Material: N/A Top Ply: 1 Top Ply Fastener/Bonding Material: SELF -ADHERING Surfacing: N/A Fastener Spacing for Anchor/Base Sheet Attachment: Zone 1':—" oc @ Lap, # Rows @ "oc Zone 1:_" oc @ Lap, # Rows @ "oe Zone 2:_" oc @ Lap, # Rows @ "on Zone 3:—" oc @ Lap, # Rows @ "oo Number of Fasteners Per Insulation Board: Zone 1': Zone 1: Zone 2: Zone 3: Illustrate Components Noted and Details as Applicable: Woodblocking, Gutter, Edge Termination, Stripping, Flashing, Continuous Cleat, Cant Strip, Base Flashing, Counterflashing, Coping, Etc.. Indicate: Mean Roof Height, Parapet Height, Height of Base Flashing, Component Material, Material' Thickness, Fastener Type, Fastener Spacing or Submit Manufacturers Details that Comply with RAS 111 and Chapter 16. . T LUCIE Section A (General Information) Master Permit No. Process No. Contractors Name: ONE CONSTRUCTION & ROOFING CONTRACTORS, INC License # CCC-1330623 Job Address 4712 Seagrape Dr. Fort Pierce, FI 34982 ROOF CATEGORY X Low Slope ❑ Mechanically Fastened Tile ❑ Mortar/Adhesive Set Tiles XAsphaitic Shingles ❑ Metal Panel/Shingles ❑Wood Shingles/Shakes ❑ Prescriptive BUR-RAS 150 ROOF ROOF TYPE. ❑ New roof ❑ Repair ❑ Maintenance X Reroofing ❑ Recovering ROOF SYSTEM INFORMATION ft. Total(SF)2,1a1 sq. ft Low Slope Roof Area (SF) 501 sq ft Steep Sloped Roof Area (SF) 1680 sq. Section B (Roof Plan) Sketch Roof Plan: Illustrate all levels and sections, roof drains, scuppers, overflow scuppers and overflow drains. Include dimensions of sections and levels, clearly identify dimensions of elevated pressure zones and location of parapets. ('!^o )