Loading...
HomeMy WebLinkAboutRevisions; Windows ChangeOFFIE USE ONLY: DATE FILED: REVISION FEE: T� LOCATION/SITE ADDRESS: 10 r_0 DESCRIPTION OF PROJECT PERMIT # RECEIPT# PLANNING & DEVELOPMENT SERVICES RECEIVED BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE JUL 2 1 2021 FORT PIERCE, FL 34982.5652 (772) 462-1553 St. APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION C�ic7vJ5 C-. UyV' 2dl Oh 1 WlncxoWS CONTRACTOR INFORMATION: STATE of FL REG./CERT. # ST!. LUCIE CO CERT. #: BUSINESS NAME: QUALIFIERS NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): FAX: OWNER/BUILDER INFORMATION: NAME: ,h�P—K. e ADDRESS- 0 (S I CA 1 I CITY: 1' I Q�Cs�_ ST? PHONE (DAYTIME: ARCHITECT/ENGINEER INFORMATION: NAME: In ADDRE (7kCA l CITY: ST1 PHONE (DAYTIME): -1-7a 3 SLCCC: 9123109 Revised 06130117 FAX: �� GOV, 1.3'-0 1/2' 6'-4" 81 1/2" '-4 3/8" 5'-8 3/4" 3'-0" 4'-0, 3'-1 1/4' 6'-9 1/8" 6'-4 12'-5 1/2' 0 _ 0" x 4'-0 x 4" CONIC SLAB W/8' x 8' THK. Q +34.02, - 7.00 GE W/1- BAR ON EXPOSED SLAB EDGES 0 ao \ \ +33.00, -42.60 +35.30, -38.20 VTW a +34.66, -37.60 +33.00, -36.00 HR5510 11'-1 3/8" 4 3/4" 2' 1 • I'' T_8" SH26 5 x 7 R 6 4 3/ CA35.5 X 6010'-0" 4 3/4` HR5510 12'-2 1 2" '\ 4 3 2'-5 1 3 4` I n \ ,�r PR 2668 4 4 2 _4 \ I I L A U N ILR Y i _ •I 5 SH \, W v I 0-1' BED`@ 0 0 Mo I I O ''; / BAT I WASH I i^ MASTER 00 N I \ I� ��� LL J "'� OFFICE BEDROOM 2868 \ 14 I �ItV°i'.I wx N I \ STE L M /BATH ,ri I -2 68 B U I \\ 9'-8 5/8" 11I 0" 5'-11 7/8't 4 3/4' -7 1/4" 4 3 4" 4'-0" °'i I\J(/E�I9�\\I • ai -6 3/4" 3'-1 1 8" SHELF & I M \ 2868 ROD, TYP. M 2868 \ 'ty N d' R.A.G. • `� in PR 2668 •V IIn In o \ \ ry6ro0 AC I - - ----- ao • N _ 3,�)_ McoTI68 REFG,N IM inIn M + ATTIC PULL -DOWNS AIR I 1 I 6'-0 3/4" 1' p• 3'_¢• 1' COORDINATE LOCATION W1 1 EXISTING TRUSSrLAYOUT� G A R A G,e/ 1143%1 3 .f 18°-5 1/4" / - 3'- 3 4" _ p• 3/4" o / 431/4 KI CHE I 0 DINING I / E I I ri y / in I In / MW/0 EN _ZL 211 4 4" TOWF R 37'-1 N CA34 X 49 CA34 X 49 +35.14, -38.05 +35.14, -38.05 - LAST ROOF OVERHANG SHOWN DASHED- - - - - - - - - - - - - 1 I EXIST. CONC. WALKWAY 3 611 B U I L D I N G A R E A S o 2,044.5 GROSS S.F. 436.6 GARAGE NET S.F. 1,456.2 NET A/C S.F. DIMENSIONAL CONTROL FLOOR PLAN SCALE : 1/4' = 1'-0' / 8'-5 3/8" 00 I\i / WIC O II I O / 2668 SHELF & ROD, 1p / TYP. 3 SIDES 3068 \ M \ 20'-9 3/8' v m CD \ In I M \\ U Lq q I M \ + \ I LIV`1.N G ROOM 0M \\ \\ ; I \\ o 9 I _ i 0, -36.70 CA22.5 X 56.5/PW5540/CA22.5 X 56.5 \ +35.30, -38.20 +35.30, -38.20 \ \ 1 4 - 3'-4" 5'-3 3/8" 6'-0" 1' 4 5 " a. A• 41 . T, n" n 0 GENERAL NOTES ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH ALL APPLICABLE CODES / AGENCIES HAVING JURISDICTION. 2. THESE DOCUMENTS ARE NOT TO BE CONSTRUED AS BEING ALL INCLUSIVE. REFER TO DOCUMENTS PREPARED BY OTHERS FOR CIVIL, STRUCTURAL, ROOF SYSTEM DESIGN, MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, LANDSCAPE AND IRRIGATION FOR THOSE REQUIREMENTS AS CONTAINED SPECIFICALLY IN EACH OF THE SEPARATE PACKAGES LISTED ABOVE. 3. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK SHOWN BY THESE DOCUMENTS AND FOR COORDINATION WITH ANY AND ALL OTHER DOCUMENTS PREPARED BY OTHERS. 4. ALL RATED PARTITIONS AND/OR ASSEMBLIES SHALL MEET APPROPRIATE U.L. STANDARDS AND ALL PENETRATIONS THRU RATED CONSTRUCTION SHALL CONFORM WITH APPLICABLE RATED ASSEMBLY INSTALLATION. 5. ALL WORK REQUIRED TO BE EXECUTED BY SUBCONTRACTORS SHALL BE PERFORMED BY COMPETENT FIRMS EXPERIENCED IN THE INSTALLATION OF THEIR SPECIFIC WORK. EACH SUBCONTRACTOR MUST HOLD CURRENT STATE REGISTRATION OR ST. LUCIE COUNTY/CITY OF FORT PIERCE CERTIFICATE OF COMPETENCY, AS WELL AS OTHER LICENSES WHICH MAY BE REQUIRED BY THE GOVERNING MUNICIPALITY IN WHICH THE PROJECT IS LOCATED. 6. BEFORE COMMENCING WORK, EACH CONTRACTOR/SUBCONTRACTOR SHALL VERIFY MEASUREMENTS, LOCATIONS AND COORDINATE AS REQUIRED BETWEEN ALL RELATED TRADES. 7. THE CONTRACTOR SHALL SUPPLY AND INSTALL ALL NECESSARY DEVICES AND EQUIPMENT TO ENSURE SAFE, FULLY OPERATIONAL AND WORKABLE SYSTEMS AND BUILDING. 8. ANY DISCREPANCIES WITH THE DRAWINGS, DIMENSIONS, CONFLICTS OR OTHERWISE, SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND VERIFIED PRIOR TO CONSTRUCTION. 9. TERMITE CONTROL SHALL BE PROVIDED BY APPLICATION OF SOIL TREATMENT SOLUTION CONSISTING OF CHLORPYRIFOS (DURSBAN TC) 1.0 PERCENT IN WATER EMULSION BELOW ALL SLABS ON GRADE, INTERIOR AND EXTERIOR FOUNDATION PERIMETERS TO A DISTANCE OF FIVE FEET BEYOND BUILDING EXTERIOR AND CARRY A FIVE YEAR GUARANTEE. 10. GYPSUM WALLBOARD SHALL COMPLY WITH ASTM C36 AND SHALL BE 5/8" THICK. PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT WALLS BEHIND WET AREAS. 11. SHOP DRAWINGS SIGNED, SEALED AND DATED BY A STATE OF FLORIDA LICENSED ENGINEER SPECIFYING ALL CONNECTION DETAILS AND WIND FORCES AND/OR LATERAL FORCES SHALL BE PROVIDED FOR ALL ALUMINUM ENTRANCES AND STOREFRONTS, EXTERIOR HOLLOW METAL DOORS, EXTERIOR OVERHEAD DOORS, GUARDRAILS AND HANDRAILS TO DEMONSTRATE COMPLIANCE WITH ALL APPLICABLE CODES AND AGENCY REQUIREMENTS. 12. FIRE EXTINGUISHERS SHALL HAVE A U.L. LABEL RATING OF 4A-60BC MODEL #COSMIC 10E AS MANUFACTURED BY J.L. INDUSTRIES OR EQUIVALENT WITH WALL BRACKET. LOCATION AND MOUNTING SHALL COMPLY WITH ALL CODES. 13. THESE DRAWINGS SHOULD NOT BE SCALED TO OBTAIN DIMENSIONS. REFER TO DIMENSIONS INDICATED. ANY DIMENSION NOT PROVIDED OR MIS -LABELED SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO CONSTRUCTION. 14.ICYNENE FOAM INSULATION TO BE APPLIED TO THE UNDERSIDE OF ALL PLYWOOD SHEATHING 0 THE EXISTING WOOD TRUSS TOP CHORDS, PER SECTION A/A-4.0. ICYNENE FOAM INSULATION ALSO TO BE APPLIED TO ATTIC SIDE OF GARAGE CEILING AND EXTEND PAST PARTITION WALLS ENCLOSING THE GARAGE. PARTITON WALLS ENCLOSING THE GARAGE TO BE FILLED FULL HEIGHT W/FIBERGLASS BATT INSULATION, R=13 MIN. s� • i01 2021 St. Lude -County Perff al -a 150 APPLICABLE CODES A. FLORIDA BUILDING CODE, SIXTH EDITION - EXISTING BUILDING, LEVEL 3 ALTERATION B. FLORIDA BUILDING CODE, SIXTH EDITION - RESIDENTIAL 1 C. FLORIDA BUILDING CODE, SIXTH EDITION - PLUMBING D. FLORIDA BUILDING CODE, SIXTH EDITION -MECHANICAL r E. FLORIDA BUILDING CODE, SIXTH EDITION - FUEL GAS is F. NATIONAL ELECTRIC QODE (NEC), 2014 WITH ALL AMENDMENTS & REVISIONS G. 2017 FLORIDA FIRE PREVENTION CODE (FFPC)(NFPA-1, NFPA-101} d B Don Bergman ARCHITECTURE, LLC P:772-466-5832 C: 772-708-0164 License No. AA 26002432 P.O. Box 13537 4362 Gator Trace Lane Fort Pierce, Florida 34982 Rigdon Residence Garage Conversion 110151 S. Indian River Dr. IFort Pierce, FL �e 'V'1 rn 21 C'onsulian t Q 2019 Don Bergman Architecture LLC This document, Sheet No. A-1 A has been prepared specifiicslly for this Project. This document is not suitable for use on other projects or in other locations without the approval and participation of Don. Bergman Architecture, LLC AR0013560. Reproduction and/or reuse is prohibited. Sheet Title : Dimensional Control Floor Plan S001e: 1/4,=1'-0, Revisions : Q3 07.19.21 WINDOW CHANGES ( Comm.: Date: 19-004 06.25.19 Drawn: Checked: DBA DUB S1-:eet TiTo. `aO� Ap111.0 II o ff: 00 dIb 04.12.10 ICYNENE FOAM INSULATION, THICKNESS AS G REQ'D FOR R=30 MIN. i 5/8" GYPSUM DRYWALL ON TRUSS BOTT. CHORDS EXISTING MASONRY BOND BEAM 8" x 8" x 16" CONC BLOCK IN 1/2 RUNNING BOND TAILORED FOAM CORE —FILL 500 FOAM INSULATION IN ALL NEW & EXIST. MASONRY WALLS TO FULL HEIGHT OF WALL. 8" CONC. BLOCK IN 1/2 RUNNING BOND 3/4" CEMENT PLASTER ON 8' CONC BLOCK MATCH EXIST. PLASTER THICKNESS & TEXTURE TYPICAL FILLED CELL: 1—#5 DOWEL IN GONG FOOTING & 1—/5 BAR VERT.IN CONC BLOCK CELL. FILL BLOCK CELL W/3000 PSI CONC. SEE FOUNDATION PLAN FOR FILLED CELL LOCATIONS Alb 04.12.10 5/8' GYPSUM DRYWALL ON 1x" P.T. FURRING STRIPS 0 16" O.C. PROVIDE 1" x 4" P.T. FURRING 0 TOP & BOTTOM OF ALL WALLS & AROUND ALL OPENINGS. HOT DIPPED GALV. MASONRY TIES 0 16' O.C. VERT. #5 DOWEL W/6" MIN. EMBEDMENT INTO EXIST. CONC SLAB/FOUNDATION — SET W/HIGH STRENGTH NON —SHRINK GROUT. SPACING NOT TO EXCEED 32" O.C. EXISTING CONCRETE SLAB & MONOLITHIC FOOTING WOOD TRUSS BEARING ELEVATION +8 —0 WINDOW HEAD ELEVATION +6 —8 FINISH FLOOR ELEVATION +0'-0" A^_e Don Bergman ARCHITECTURE, LLC P: 772-466-5832 C: 772-708-0164 License No. AA 26002432 P.O. Box 13537 4362 Gator Trace Lane Fort Pierce , Florida 34982 Rigdon Residence Garage Conversion 10151 S. Indian River Dr, Fort Pierce, FL Seal: LAPg JUL 2 0 202 Consult _ 02019 Don Bergman Architecture LLC This document, Sheet No. A-3.0 has been prepared specifically for this Project. This document is not suitable for use on other projects or in other locations without the approval and participation of Don Bergman Architecture, LLC AR0013560. Reproduction and/or reuse is prohibited. Sheet Title: Wall Section Product Approval Scale: 1 4"=V-0' Revisions : r A�07.19.21 WINDOW CHANGES Comm.: Date: 19-004 04.11.19 Drawn: Checked: DBA DLB C" io 3/4" RAISED STUCCO BAND ca w x Z z WIND ENING z o S z 3 3/4" RAISED STUCCO BAND', 3" RAISED STUCCO BAND IL io i0 N \ g 1 1/2 J #5 DOWEL W/6' MIN. EMBEDMENT INTO EXIST. CONC BOND BEAM - SET W/HIGH STRENGTH NON -SHRINK GROUT. 11 Z A -7 _ L NEW WI OPNG C�' DO R I r❑ NEW DO PNG TYPICAL FILLED CELL: L 1 DOWEL IN CONC FOOTING & 1- 5 R O ENI G I-EIFE :pq _P -I V IN CONC BLACK CELL FILL BLO�K ELL - _ _ r 1T I I C L F R R�LEDI CE�LLCLOCATIONS SEE NDATION P � T' �I � 3'`I I #5 DOWEL W/6" MIN. EMBEDMENT INTO EXIST. CONC REFER TO FLOOR PLAN FOR ADDITIONAL MASONRY SLAB/FOUNDATION — SET W/HIGH STRENGTH NON —SHRINK FILLED CELLS NOT SHOWN IN THIS ELEVATION GROUT. SPACING NOT TO EXCEED 32" O.C. I_ JZ67 .NEW 8' CONC MASONRY IN 1/2 RUNNING BOND _ — V/HOT DIPPED GALV. MASONRY TIES 0 16' O.C. CUT BLOCK SHOWN HATCHED— NO MASONRY TO BE LESS THAN 4' IN WIDTH. PRECAST CONC. WINDOW SILL, WINDOW OPENINGS NEW PGT VINYL FIXED PICTURE WINDOW #5 DOWEL W/6" MIN. EMBEDMENT INTO NEW PGT VINYL FRENCH DOOR W/ NEW PGT VINYL CASEMENT WINDOW EXIST. CONC BOND BEAM - SET W/HIGH INSULATED IMPACT GLAZING W/NEW PRECAST CONC SILL STRENGTH NON -SHRINK GROUT. -----"----------- ---- ---- -- ---------- TOP OF MASONRY BEAM ELEVATION +8 -0 WINDOW HEAD-APPROX. / \ ELEVATION +6 -8 TYPICAL FILLED GEUL 1- DOWEL IN CONIC F001I G & 1-/5 BAR NEW 3 4 CEMENT PLASTER ON 8' CONIC IN CONIC 'LOCK CELL. ILL BLOCK CELL W 300G PSI SEE FO DATKNT PLAN / I \ I I MASONRY WALL WALL SHOWN HATCHED. LOCATIONS i .- `" "' SEE FRONT ELEVATION ABOVE EXIST. GARAGE DOOR W//SHUTTERS I I I \ NEW PGT VINYL CASEMENT WINDOW & SHUTTER BRACKETS 70 REMAIN I W/NEW PRECAST CONIC SILL +35.14, -3 .0 8 +35.14, -38.05 \ -- ---- -- -- - -- _ - FINISH FLOOR APPi GRADE #5 DOWEL W/6' MIN. EMBEDMENT INTO DUST. CONIC ��� ELEVATION+O-0' SLAB/FOUNDATION - SET W/HIGH STRENGTH NON -SHRINK +33.70, -36.7 +35.30, -38,20 +35.30, -38.20 +35.30, -38.20 GROUT. SPACING NOT TO EXCEED 32" Q.C. 8" CONIC FILLED CELL W/1-15 BAR EA. #5 DOWEL W/6- MIN. EMBEDMENT INTO SIDE OF EXIST. MASONRY OPENING EXIST. CONC BOND BEAM — SET W/HIGH NEW PGT VINYL FRENCH DOOR W/ STRENGTH NON —SHRINK GROUT. INSULATED IMPACT GLAZING -------------------- ------------- TOP OF MASONRY BEAM fdEVA710N +8'-0' NEW PGT VINYL HORIZONTAL ROLLING WINDOW I I I \ I I 1 I I 1 I in ELEVATION +6 —8 W/NEW PRECAST CONC SILL 1 I / NEW PGT VINYL SINGLE —HUNG WINDOW W/NEW PRECAST I I NEW PGT VINYL HORIZONTAL ROLLING WINDOW W/NEW PRECAST CONIC SILL CONC SILL 8' CONIC FILLED CELL W/1-#5 BAR EA. / SIDE OF EXIST. MASONRY OPENING 8' CONIC FILLED CELL W/1-J5 BAR EA. I I / I I I I I I SAWCUT At REMOVE A PORTION OF THE EXIST. SIDE OF EXIST. MASONRY OPENING—� I I I \ I 8" CONC. MASONRY WALL AND EXIST. EXTERIOR FINISH TO THE WIDTH AS SHOWN AND AS REQ'D I I I 1 1 I 1 TO PROVIDE THE ROUGH OPENING FOR THE I I I 1 I I 1 SCHEDULED WINDOW TO BE INSTALLED, --- --— _ — ----- ---- —-- -- ----- — ------------ __ FINISH FLOOR ELEVATION +0'-0' +33.00, —36.00 +34.66, —37.60 +34.02, -37.00 +35.30, -38.20 +33.00, -42.60 NEW PRECAST CONC. WINDOW SILL SAWCUT & REMOVE A PORTION OF THE EXISTING 8' CONCRETE MASONRY WALL SAWCUT & REMOVE A PORTION OF THE EXISTING 8" CONCRETE MASONRY WALL AND EXIST. EXTERIOR FINISH TO THE WIDTH AS SHOWN AND AS REQUIRED TO AND EXIST. EXTERIOR FINISH TO THE WIDTH AS SHOWN AND AS REQUIRED TO PROVIDE THE ROUGH OPENING FOR THE SCHEDULED WINDOW TO BE INSTALLED. PROVIDE THE ROUGH OPENING FOR THE SCHEDULED DOOR TO BE INSTALLED. 5 DOWEL W/6' MIN. EMBEDMENT INTO EXIST. CONIC 4'-0' x 4'-0' x 4' OONC SLAB W/8' x 8' Ti EDGE W/1-5 BAR ON EXPOSED SLAB EDGES SLAB/FOUNDATION — SET W/HIGH STRENGTH NON —SHRINK GROUT. SPACING NOT TO EXCEED 32" O.C. EXTERI ELEVATIONS" SCALE : 1/4' = 1'-0" Don Bergman ARCHITECTURE, LLC P:772-466-5832 C: 772-708-0164 License No. AA 26002432 P.O. Box 13537 4362 Gator Trace Lane Fort Pierce, Florida 34982 Rigdon Residence Garage Conversion 10151 S. Indian River Dr. Fort Pierce, FL k Q 2019 Don Bergman Architecture LLC This document, Sheet No. A-3.0 has been prepared spmfirally for this Project. This document is not suitable for use on other projects or in other locations without the approval and participation of Don Bergman Architecture, LLC AR0013560. Reproduction and/or II reuse is prohibited. Sheet Title Exterior Elevations Scale: 1/4'=1'-O' Revisions : Q3 07.19.21 WINDOW CHANGES ~i tl a Comm.: Date: 19-004 04.11.19 Drawn Drawn : Checked: DBA STUCCO WINDOW SURROUND 1 DETAIL Scale: dlb 04.12.10 �00 #5 MIN. EMBEDMENT INTO IST. CONC BOND BEAM -SET W/HIGH - - - STRENGTH NON -SHRINK GROUT�� NEW PGT VINYL CASEMENT WINDOW W/LAMINATED , INSULATED IMPACT GLASS I I I 8" CONC FILLED CELL W/1-/5 BAR EA. SIDE OF EXIST. MASONRY OPENING #5 DOWEL W/6' MIN. EMBEDMENT INTO 3 EXIST. CONC SLAB/FOUNDATION - SET I I W/HIGH STRENGTH NON -SHRINK GROUT. I I SPACING NOT TO EXCEED 32"" O C.—� - - ■ PRECAST CONC SILO TYP. +35.30, -38.20 SAWCUT & REMOVE A PORTION OF THE EXISTING 8" CONCRETE MASONRY WALL AND EXIST. EXTERIOR FINISH TO THE WIDTH AS SHOWN AND AS REQUIRED TO PROVIDE THE ROUGH OPENING FOR THE SCHEDULED WINDOW TO BE INSTALLED. +34.50, -37.45 EXTERIOR ELEVATIONS SCALE : 1/4" = 1'-0" NEW 8" CONC MASONRY INFILL -WALL PROVIDE DOWELS — — ® 16" O.C. VERT.T. TOP OF MASONRY BEAM ELEVATION +8 -0 WINDOW HEAD-APPROX. ELEVATION +6 -8r— I I FINISH FLOOR ELEVATION +0'-0' +35.30, -47.20 I -i- I —314" CEMENT PLASTER ON NEW 8 INFILL MASONRY - MATCH IXI3T.1�� FINISH & TEXTURE I —NEW PGT VINYL CASEMENT WINDOW I W/NEW PRECAST CONIC SILL +35.30, -38.20 NEW PGT VINYL CASEMENT WINDOW W/NEW PRECAST CONC SILL TOP OF MASONRY BEAM ELEVATION +8 -0 WINDOW HEAD -APPROX. io ELEVATION +6 -8 SAWCUT & REMOVE A PORTION THE EXIST. 8" CONC. MASONRY WALL AND EXIST. ST. EXTERIOR FINISH TO THE WIDTH AS SHOWN AND AS REQ'D TO PROVIDE THE ROUGH OPENING FOR THE SCHEDULED WINDOW TO BE INSTALLED. 8" CONC FILLED CELL W/1-#5 BAR EA. SIDE OF EXIST. MASONRY OPENING FINISH FLOOR - - APPROX. GRADE ELEVATION +0'-O" WOOD WINDOW STOOL W/ 3/8"EASED EDGE WOOD WINDOW STOOL W/ 3/8"EASED EDGE ALUM. CLAD WOOD CASEMENT WINDOW ALUM. CLAD WOOD CASEMENT WINDOW W/LAMINATED IMPACT GLASS W/LAMINATED IMPACT GLASS 1 CAULK ALL INTERIOR & EXTERI R CAULK ALL INTERIOR & EXTERIOR WINDOW PERIMETERS WINDOW PERIMETERS 5/8" GYPSUM DRYWALL ON 1"x P.T. FURRING 016" O.C. - --- L PRECAST OR CAST IN -PLACE PRECAST OR CAST IN -PLACE - _ CONCRETE SILL CONCRETE SILL 4 fO ° 5/8" CEMENT P STER L / W/SMOOTH FINISH. a t0 � 5/8" CEMENT P STER 3" , CEMENT PLASTER CORBEL; 3" W/SMOOTH FINISH. TYP. OF 2 CAULK ALL INTERIOR & EXTERIOR cv -- WINDOW PERIMETERS F 1 �, ALUM. CLAD WOOD CASEMENT WINDOW 5/8" GYPSUM DRYWALL ON 1"x _ ;o W/LAMINATED IMPACT GLASS5/8" P.T. FURRING 016 O.C. e M GYPSUM DR W LL ON 4x/ P.T. FURRING 0100,.C. WOOD CASEMENT WINDOW d�e� WOOD CASEMENT WINDOW 2 WOOD CASEMENT WINDOWHEAD DETAIL — JAMB SIM. DETAIL SILL DETAIL @ CORBELS rSILL 3=IScale:" 3Sc'lea" Don Bergman ARCHITECTURE, LLC P:772-466-5832 C: 772-708-0164 License Na AA 26002432 P.O. Box 13537 4362 Gator Trace Lane Fort Pierce, Florida 34982 Rigdon Residence Garage Conversion 10151 S. Indian River Dr. Fort Pierce, FL Seal: ; Consultari Q 2019 Don Bergman Architecture LLC This document, Shot No. A-3.1 has been prepared specifically for this Project. This document is not suitable for use on other projects or in other locations without the approval and participation of Don Bergman Architecture, LLC AR0013560. Reproduction and/or reuse is prohibited. Sheet Title: Exterior Elevations Scale: 1/4"=1'-0' Revisions : ,! 07.19.21 WINDOW CHANGES Comm.: Date: 19-004 04.11.19 Drawn: Checked: DBA DLB Sheet No. A-3.1 dlb 04.12.10