Loading...
HomeMy WebLinkAboutAnchor Bolt PlansSEE PLAN OUT TO OUT CONCRETE SEE PLAN W OUT TO OUT STEEL x w a W PROJECTION n . e1 . e CONCRETE D. AND ANCHOR BOLT PROJECTION CONCRETE EDGE AND ANCHOR BOLT PROJECTII AT SLAB WITHOUT NOTCH SLAB BEYON FINISHED FLOOR JAMB DEPTH VALL PANEL #12 x 1 1/4' SDS INSIDE CLOSURE 1-1/2, MASHER ' (6' aCJ 1/2' BASE ANGLE 2 x4'x16GA FBQSIED FLDDR - SECTION 'A -A' 1-3/4' FA,WIDTH 1-3/4' 'A -A' • STD BASE TRIM V4' x 1' NAIL -Di ANCIM ° aW _j ° (DTR) 2 36' IM (BY aMS) o a BASE ANGLE VIM BASE TRIM AND BASE O.OSIM VITFOUT SHEETING NOTCH TYP. OVERHEAD DOOR RECESS DETAIL ANCHOR BOLTS NOTES MANUFACTURER RECOMMENDS USE OF STRAIGHT ROD ANCHOR BOLTS WITH NUT AND WASHER ON BOTH ENDS AS OPPOSED TO J-BOLTS OR ANCHOR BOLTS WITH HOOKS BECAUSE OF BETTER PERFORMANCE RESULTS IN CONCRETE FOUNDATIONS. THE TYPE OF BOLT USED FOR THE PROJECT SHALL BE DETERMINED BY THE FOUNDATION ENGINEER WITH THE BOLT STRENGTH MEETING OR EXCEEDING THAT OF AN ASTM F1554 GRADE 36 (MIN.) BOLT. ANCHOR BOLT PLAN NOTE: All Base Plates 0 100'-0" (U.N.) DESCRIPTION, ANCHOR BOLTS n/rLAI WAZIMM SEE BUILDING PLANS CONCRETE LINE FOR PROJECTION z •• TOTAL LENGTH OETERMINm HEX NUT < BY FOUNDATION ENGINEER •• W/FLAT WASHER o . IT ANCHOR BOLTS SHALL BE ASTM F1554 GRADE 36 MIN. OR GRADE 55 to, /� (27134-2) �N Iw1 dIaM1 VULCAN STEEL STRUCTURES, INC E I FINAL ERECTION PROJECT MAVERICK BOATS EX] FOR CONSTRUCTION ID 27134-1 E 1 FOR APPROVAL PROJECT I I NOT CONSTRUCTION ADDRESS FORT PIERCE, FL 34946 ANCHOR BOLT SUMMARY Dia Proj Qty Locate (in) Type (in) 036 Jamb 5/8" F1554 3.00 020 Endwall 3/4" F1554 3.00 072 Frame 314" F1554 3.00 X 68 Frame 1 F1554 4.00 VANESSA L BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 ,411111111iIfl#11#Blfi;; ,.•`���*! SSA L. flitj�44''�. i No.83970 STATE OF ' .,,,9�•. A'LOR10P''���� SEE PLAN x OUT TO OUT CONCRETE L� SEE PLAN w x OUT TO OUT STEEL w a w PROJECTION • . a CONCRETE EDGE AND ANCHOR BOLT PFMJFCTIrIN ANCHOR BOLTS NOTES MANUFACTURER RECOMMENDS USE OF STRAIGHT ROD ANCHOR BOLTS WITH NUT AND WASHER ON BOTH ENDS AS OPPOSED TO J-BOLTS OR ANCHOR BOLTS WITH HOOKS BECAUSE OF BETTER PERFORMANCE RESULTS IN CONCRETE ,FOUNDATIONS. THE TYPE OF BOLT USED FOR THE PROJECT SHALL BE DETERMINED BY THE FOUNDATION ENGINEER WITH THE BOLT STRENGTH MEETING OR EXCEEDING THAT OF AN ASTM F1554 GRADE 36 (MIN.) BOLT. ANCHOR BOLTS ANCHOR BOLT SUMMARY N/FLATHEX WAASHER SEE BUILDING PLANS FOR PROJECTION CONCRETE LINE Qty Dia Locate (in) Type Proj (in} O 32 Jamb 5/8" F1554 3.00 w 020 Endwall 3/4" F1554 3.00 -� •• TOTAL LENGTH DEfERMINm 0 84 X 68 Frame 3/4" Frame 1 F1554 F1554 3.00 4.00 HEX NUT ¢ BY FOUNDATION ENGINEER •• W/FLAT WASHER a i ANCHOR BOLTS SHALL BE ASTM - I (27134-1) 27134-2) N v SLAB BEYUN ... _.._ .... .. ., FINISHED FLOOR JAMB DEPTH VALL PANEL t12 x I V4' SDS INSIDE CLOSURE 1-1/ VNASIER <6. HER BASE ANGLE a 2'x4'x16GA ISHED FL®R SECTION 'A -A' 1-3/4' F.D.WIDTH 1-3/4' 'A -A' a STA BASE TRIH V4'xP NAIL -RN ANCHOR o o (DTR) B 36• DC. 0HY OTHERSI a o BASE ANGLE WITH BASE TRIM AND BASE CLOSURES VIONIXIT SHEETING NOTCH TYP. OVERH A➢ DOOR R1:ESS D TAI ANCHOR BOLT PLAN NOTE: All Base Plates ® 100'-0" (U.N.) * = 1-3/4"11 KEY PLAN E I FINAL ERECTION EXI FOR CONSTRUCTION I I FOR APPROVAL E I NOT CONSTRUCTION VULCAN STEEL STRUCTURES, INC I RK FORT PIERCE, FL 34946 VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 oSA g • i s ii No. * 970 00 STATE OF *c l+Rtlft/�itltll��t���� ORIGINAL SIGNATURE REQUIRED *1INjo 2 OF 28 4 4 4 4 Q Q COLUMN LINE ENDWALL COLUMN: BASIC COLUMN REACTIONS (k ) Wind Wind Frm Col Dead Press Suct Et PAT-LLt- El PAT-11 9- E1 PAT LL-3- E1 PAT-LL4- E1 PAT-IL5- Line Line Vert Harz Harz Harz Vert Harz Vert Harz Vert Harz Vert Harz Vert 1 F • -16.4 18.1 0.0 6.9 0.0 2.7 0.0 -0.3 0.0 0.1 0.0 3.2 1 E • -17.7 19.5 0.0 2.8 0.0 6.7 0.0 2.8 0.0 -0.3 0.0 2.9 1 C • -18.9 20.8 0.0 -0.3 0.0 2.8 0.0 6.7 0.0 2.7 0.0 2.9 1 B * -20.1 22.2 0.0 0.1 0.0 -0.3 0.0 2.7 0.0 7.0 0.0 3.3 1 A 1.0 -10.8 12.7 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Frm Col E1 PAT-LL_6- Line Line Harz Vert 1 F 0.0 3.3 1 E 0.0 2.9 1 C 0.0 2.8 1 B 0.0 3.3 1 A 0.0 0.0 Wind Wind Wind Wind Frm Col Dead Collat ---Live--- Left1 Rightl Left2 Right2 Wind -Press Wind -Suet Line Line Vert Vert Harz Vert Vert Vert Vert Vert Harz Vert Harz Vert 35 A 1.3 0.8 0.2 2.4 -8.3 -8.3 -8.3 -8.3 -10.2 -8.4 13.0 -5.9 35 B 1.8 1.4 0.4 3.3 -13.7 -13.7 -13.7 -13.7 -20.4 -13.8 22.5 -10.2 35 C 1.7 1.4 0.4 3.3 -13.7 -13.7 -13.7 -13.7 -19.2 -13.8 21.2 -10.2 35 E 1.3 0.8 0.2 2.4 -8.3 -8.3 -8.3 -8.3 -17.0 -8.4 19.6 -5.9 35 F 1.1 0.0 0.0 0.0 0.0 0.0 0.0 0.0 -16.3 0.0 18.0 0.0 Wind Wind Frm Col Longt Long2 Line Line Vert Vert 35 A -8.4 -1.9 35 B -13.8 1.9 35 C -13.8 1.9 35 E -8.4 -1.9 35 F 0.0 0.0 -See Rigid Frame Interior Column Reactions BUILDING BRACING REACTIONS f Reactions(k ) PaneLShear -Wall -Cal -Wind - -Seismic- (Ib/ft) Loc Line Line Harz Vert Harz Vert Wind Seis Note L-EW 1 (h) F SW A f R-EW 35 h B-SW G 33,32 6.6 6.9 1.7 1.8 27,26 6.6 6.9 1.7 1.8 21,20 6.6 6.9 1.7 1.8 15,14 6.6 6.9 1.7 1.8 9,8 6.6 6.9 1.7 1.8 4,3 6.6 6.9 1.7 1.8 (08racing loads are applied to adjacent building (h)Rigid frame at endwall DESIGN LOAD DEFINITIONS RIGID FRAME LOAD CASE DEFINITIONS FRAME LINES: 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 T T COLUMN LINE u H fv fv RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) 1 G 4 0.750 8.000 12.00 0.500 0.0 1 F 4 0.750 8.000 12.50 0.500 0.0 1 E 4 0.750 8.000 12.50 0.500 0.0 1 C 4 0.750 8.000 12.50 0.500 0.0 1 B 4 0:750 8.000 12.50 0.500 0.0 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) 20 G 4 0.750 8.000 12.25 0.625 0.0 2• D 4 1.000 10.00 10.00 1.000 0.0 2• Frame lines: 2 3 4 5 6 7 8 9 10 11 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in Elev.Line Line Qty Dia Width Length Thick (in) 13 G 4 0.750 8.000 12.25 0.500 0.0 13 D 4 1.000 10.00 10.00 1.000 0.0 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col A.nc.-Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) 19 G 4 0.750 8.000 12.25 0.500 0.0 19 D 4 1.000 10.00 14.25 1.000 0.0 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) 20• G 4 0.750 8.000 12.25 0.625 0.0 20• D 4 1.000 10.00 14.25 1.000 0.0 20• Frame lines: - 20 21 22 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length ick (in) 23• G 4 0.750 8.000 12.25 0.625 0.0 230 D 4 1.000 10.00 14.25 1.000 0.0 23• Frame lines: 23 24 25 26 27 28 29 30 31 RIGID FRAME: ANCHOR BOLTS & BASE PLATES RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Line Line Anc.-Bolt Base -Plate (in) Elev. Qty Dia Width Length Lk Frm Col Anc-Bolt Base -Plate (in) Elev. (in) Line Line Qty Dia Width Length ick (in) 14 G 4 0.750 8.000 12.25 0.625 0.0 32 G 4 0.750 8.000 12.50 0.625 0.0 14 D 4 1.000 10.00 10.00 .1.000 0.0 32 D 4 1.000 10.00 12.00 1.000 0.0 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) 15• G 4 0.750 8.000 12.25 0.625 0.0 150 D 4 1.000 10.00 10.00 1.000 0.0 15• Frame lines: 15 16 17 18 Wlnd_LI/Wlnd_RI = Lateral wind load from the left/right with a negative Internal pressure coefficient. Wind_L2/Wlnd_R2 = Lateral wind Load from the left/right with a positive Internal pressure coefficient. Wlnd_Lnl = LongltudinaL wind load with a negative Internal pressure coefficient. Wlnd_Ln2 = Longitudinal wind load with a positive Internal pressure coefficient. Selsmlc_L/Selsmlc_R = Lateral Seismic load from left/right. LWIND#_L#E/ LWIND#_R#E = Longitudinal wind loads for edge zones. F#UNB_SL_L/ F#UNB_SL_R = Unbalanced roof snow load with wind from the Left/right. F#PAT_LL # = Pattern live load for continuous bean systems. 'Note, Bracing reactions are not already Included in combination with any other load but must be added to basic reactions as desired by the foundatlon designer.' Collat = Collateral Load jEndwall Load Case Definitions) Rafter Wind_L/ Rafter Wlnd_R = Lateral wind load from the left/right. Brace Wind_L/ Brace Wlnd_R = Lateral wind load from the left/right with the bracing loads added Wind_P/Wlnd_S = Wind Pressure/Suctlon due to longitudinal wind. Wind-Ln# = Longitudinal wind toad on the roof. Selsmlc_L/Selsmic_R = Lateral Seismic load from left/right. E#UNB_SL_L/ E#UNB_SL_R = {Unbalanced roof snow Load with wind from the left/right. E#PAT_LL # = Pattern live load for continuous beam systems, LWIND#-L/LWIND#_R = Longitudinal wind loads for edge zones. MA V RIGID FRAME: ANCHOR BOLTS &BASE PLATES Frm Col Anc.-Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) 33• G 4 0.750 8.000 12.50 0.625 0.0 33• D 4 1.000 10.00 12.00 1.000 0.0 33• Frame lines: 33 34 RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate in Elev. Line Line Qty Dia Width Length( Thick (in) 35 G 4 0.750 8.000 12.25 0.500 0.0 35 D 4 1.000 10.00 12.50 1.000 0.0 ENDWALL COLUMN: ANCHOR BOLTS & BASE PLATES Frm Col Ana. -Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) 1 F 4 0.750 8.000 12.50 0.500 0.0 1 E 4 0.750 8.000 12.50 0.500 0.0 1 C 4 0.750 8.000 12.50 0.500 0.0 1 B 4 0.750 8.000 12.50 0.500 0.0 1 A 4 0.750 8.000 12.25 0.500 0.0 35 A 4 0.750 8.000 12.25 0.500 0.0 35 B 4 0.750 8.000 12.50 0.500 0.0 , 35 C 4 0.750 8.000 12.50 0.500 0.0 35 E 4 0.750 8.000 12.50 0.500 0.0 35 F 4 0.750 10.00 12.00 0.500 0.0 GENERAL NOTES (1.) APPLICATION OF ENGINEERS SEAL IS FOR METAL BUILDING ONLY AND DOES NOT REPRESENT THE PROFESSIONAL OF RECORD. (2.) FOUNDATION DESIGN AND CONSTRUCTION ARE NOT THE RESPONSIBILITY OF THE METAL BUILDING MANUFACTURER. UANCHOR BOLTS SHALL BE ACCURATELY SET TO A TOLERANCE OF +/- 1/8' IN BOTH ATION'AND LOCATION. (4.) THE BUILDING REACTION DATA REPORTS THE LOADS WHICH THIS BUILDING PLACES ON THE FOUNDATION. THE FOUNDATION IS TO BE DESIGNED BY A QUALIFIED ENGINEER TO SUPPORT THE BUILDING REACTIONS IN ADDITION TO OTHER LOADS IMPOSED BY THE BUILDING USE OR OCCUPANCY WITH RESPECT TO JOB SITE CONDITIONS. (5.) ALL ANCHOR BOLTS TO BE ASTM F1554 GRADE 36 MIN. OR GRADE 55 (UNLESS NOTED) 96.) VALUES GIVEN FOR BENDS AND ANCHOR BOLT TOTAL LENGTHS ARE SUGESTED LENGTHS N Y. IT IS THE RESPONSIBILITY OF THE FOUNDATION ENGINEER TO DETERMINE THESE VALUES SINCE THEY ARE A FUNCTION OF CONCRETE STRENGTH AS WELL AS OTHER FACTORS. (7.) WIND REACTIONS ARE BASED ON Vult. r� Xv//////�/ / ZZZ//// N KEY PLAN E I FINAL ERECTION EX] f13R CONSTRUCTION E I FOR APPROVAL E I OTHER, EXPLAIN VULCAN STEEL STRUCTURES, INC FORT PIERCE, FL 34946 VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 SSA � 0.83970 * . ' STATE OF - I ORIGINAL SIGNATURE REOUIRED I 4 RIGID FRAME: BASIC COLUMN REACTIONS (k ) Frame Column -----Dead-----Collateral- ----- Live ------ Wind_Leftt--Wind_Rightl---Wind_Left2- Line Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 1 1 G 0.0 1.0 0.0 0.8 0.0 1.7 -4.2 -9.0 5.7 -6.0 -7.5 -6.0 1 A F 0.0 0.6 0.0 2.4 0.0 0.8 0.0 1.6 4.9 -8.5 11.6 -4.1 -1.5 -6.5 1 E 0.0 2.3 0.0 2.2 0.0 4.3 0.0 -24.3 0.0 -13.6 0.0 -17.4 1 C 0.0 2.5 0.0 2.0 0.0 1.9 0.0 3.9 0.0 -21.9 0.0 -12.5 0.0 -15.5 1 B 0.0 2.8 0.0 2.2 0.0 3.8, 0.0 -21.6 0.0 -12.3 0.0 ' -15.4 0.0 4.5 0.0 -25.1 0.0 -14.3 0.0 -17.9 Frame Column-Wind_Right2- --Wind-Longl---Wind_Long2- -Seismic_Left Seismic F1PAT_LL_t- Line 1 Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert -Right Horiz Vert Horiz Vert G ' 2.3 -2.9 6.1. -10.1 6.2 -6.0 0.0 0.0 0.0 0.0 0.0 1.6 I A 5.2 -2.1 16.1 -7.5 12.1 -4.0 -0.4 0.0 0.4 0.0 0.0 0.0 1 F 0.0 -6.7 0.0 -24.0 0.0 -13.6 00 0.0 0.0 0.0 0.0 4.6 1 E 0.0 -6.2 0.0 -22.0 0.0 -12.5 0:0 0.0 0.0 0.0 0.0 1.9 1 C 0.0 -6.0 0.0 -21.6 0.0 -12.3 0.0 0.0 0.0 0.0 0.0 -0.2 1 8 0.0 -7.0 0.0 -25.1 0.0 -14.3 0.0 0.0 0.0 0.0 0.0 0.1 Frame Column F1 PAT_LL-2- F1 PAT_LL-3- F1 PAT_LL-4- Ft PAT_LL_5- Fl PAT LL_6- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 1 G 0.0 -0.2 0.0 0.0 0.0 0.0 0.0 1.9 0.0 -0.2 1 A 0.0 0.0 0.0 -0.1 0.0 1.5 0.0 1.8 0.0 -0.2 1 F 0.0 1.9 0.0 -0.2 0.0 0.1 0.0 2.0 0.0 2.2 1 E 0.0 4.5 0.0 1.9 0.0 -0.2 0.0 2.0 0.0 1.9 1 C 0.0 1.9 0.0 4.5 0.0 1.8 0.0 1.9 0.0 1.9 1 B 0.0 -0.2 0.0 1.9 0.0 4.7 0.0 2.2 0.0 2.2 Frame Column ----- Dead -----Collateral- ----- Uve------ Wind_Leftl--Wind_Rightl- --Wind-Left2- Line Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 2* 2* G A 0.5 2.9 -0.5 2.0 1.9 7.6 -1.9 5.4 1.5 7.4 -1.5 6.5 -9.3 -28.4 13.2 -24.6 3.6 -19.8 21.7 -14.6 -12.5 -15.3 -2.2 -15.1 2* D 0.0 8.4 0.0 18.2 0.0 23.6 0.0 -92.9 0.0 -57.8 0.0 -55.1 Frame Column-Wind_Right2---Wind_Longt- --Wind_Long2--Seismic-Left Seismic F2PAT_U I - Line Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert -Right Horiz Vert Horiz Vert 2* G 0.4 -6.7 4.0 -31.0 6.1 -20.3 0.0 0.0 0.0 0.0 2.5 9.4 2* A 6.4 -5.1 31.9 -23.3 25.2 -14.4 -0.6 0.0 0.6 0.0 -2.5 =1.6 2- D 0.0 -20.0 0.0 -91.6 0.0 -57.5 0.0 0.0 0.0 0.0 0.0 10.9 Frame Column F2PAT_U 2- Una Line Hartz Vert 2* G -1.0 -2.0 2* A 1.0 8.1 2* D 0.0 12.7 Frame Column ----- Dead ----- Collateral - ----- Live ------ Wtnd_Leftl- -Wind_Rightl---Wtnd_Left2- Line 13 Line G Horiz' Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 13 A 0.4 2.8 -0.4 0.7 3.6 1.3 7.3 -8.5 -27.7 3.9 -19.5 -11.8 -14.8 13 D 2.0 0.0 8.6 -0.7 3.4 0.0 12.0 -1.3 6.4 0.0 23.8 12.4 -24.5 21.4 -14.5 -2.8 -15.1 0.0 -93.7 0.0 -58.2 0.0 -55.7 Frame Column-Wind_Right2---Wind-Longl- --Wtnd_Long2--Seismic Left Seismic-Right -F3CRANEAI- Line Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Hartz Vert Horiz Vert 13 G 0.6 -6.6 4.5 -30.5 6.4 -20.0 0.0 0.0 0.0 0.0 3.2 12.6 13 A 6.2 -5.1 31.3 -23.1 25.0 -14.3 -0.6 0.0 0.6 0.0 -5.1 -1.9 13 D 0.0 -20.2 0.0 -92.3 0.0 -57.9 0.0 0.0 0.0 0.0 0.0 8.4 Frame Column-F3CRANEA2- F3PAT_H 1- F3PAT_U 2- -173CRANE43- -F3CRANEA4- Line Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 13 G 3.2 11.8 2.4 9.5 -1.1 -2.2 1.5 8.5 1.6 3.7 13 A -1.3 -1.6 -2.4 -1.5 1.1 7.9 -2.5 -0.6 -0.6 -1.1 13 D 0.0 9.0 0.0 10.7 0.0 13.0 0.0 1.6 0.0 7.1 Frame Column ----- Dead -----Collateral- ----- Live ------ Wind-Leftl- -Wtnd_Rightl---Wtnd_Left2- Una Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 14 G 0.5 3.0 0.8 3.9 1.5 7.8 -9.4 -29.7 3.3 -20.8 -12.4 -15.9 14 A -0.5 2.2 -0.8 3.4 -1.5 6.8 13.3 -26.0 22.0 -15.6 -2.3 -15.8 14 D 0.0 8.5 0.0 11.5 0.0 22.9 0.0 -90.2 0.0 -55.8 0.0 -53.8 Frame Column-Wind_Right2---Wind-Longl---Wind_Long2--Seismic-Left Seismic_Right -F4CRANEA1- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Hartz Vert Horiz Vert 14 G 0.4 -7.0 3.5 -32.6 5.8 -21.4 0.0 0.0 0.0 0.0 3.1 12.4 14 A 6.4 -5.5 32.3 -24.8 25.6 -15.4 -0.6 0.0 0.6 0.0 -5.0 -2.0 14 D 0.0 -19.4 0.0 -88.5 0.0 -55.5 0.0 0.0 0.0 0.0 0.0 8.7 Frame Column-F4CRANEA2- F4PAT H I- F4PAT_H 2- -F4CRANEA3- -F4CRANEA4- -F4CRANEA5- Une Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Hartz Vert Horiz Vert 14 G 3.1 11.6 2.3 9.3 -0.7 -1.5 1.5 8.5 1.5 3.5 -0.1 -0.2 14 A -1.2 -1.7 -2.3 -1.6 0.7 8.4 -2.4 -0.6 -0.5 -1.2 -0.9 1.7 14 D 0.0 9.3 0.0 11.0 0.0 - 11.9 0.0 1.7 0.0 7.3 0.0 11.1 Frame Column-F4CRANEA6- -F4CRANEA7- -F4CRANEA8- Une Line Horiz Vert Horiz Vert Horiz Vert 14 G -0.6 -1.2 -0.6 -1.2 -0.2 -0.4 14 A -0.4 3.8 -0.4 6.5 -0.8 9.9 14 D 0.0 10.0 0.0 7.2 0.0 3.0 Frame Column ----- Dead -----Collateral- ----- Live ------ Wind_Left1--Wind_Rightl---Vind_Left2- Une Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 15* G 0.4 2.9 0.6 3.6 1.1 7.2 -7.7 -27.5 4.1, -19.5 -11.2 -14.6 15* A -0.4 2.1 -0.6 3.3 -1.1 6.5 11.6 -24.7 21.2 -14.6 -3.5 -15.2 15* D 0.0 8.8 0.0 11.9 0.0 23.8 0.0 -93.7 0.0 -58.2 0.0 -55.7 Frame Column-Wind_Right2- --Wtnd_Longl- --Wind_Long2- -Seismic-Left Seismic -Right -F5CRANEAI- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert - Horiz Vert 15* G 0.7 -6.5 4.9 -30.4 6.5 -20.0 0.0 0.0 0.0 0.0 4.7 18.9 15* A 6.1 -5.1 30.9 -23.3 24.8 -14.3 -0.6 0.0 0.6 0.0 -7.5 -2.5 15* D 0.0 -20.2 0.0 -92.2 0.0 -57.9 0.0 0.0 0.0 0.0 0.0 11.9 Frame Column-F5CRANEA2- F5PAT_LL_1- F5PAT-LL-2- -F5CRANEA3- -F5CRANEA4- -F5CRANEA5- Une Una Horiz Vert Horiz Vert Hartz Vert Horiz Vert Horiz Vert Horiz Vert 15* G 4.7 17.7 2.2 9.6 -1.0 -2.4 1.3 8.5 1.5 3.8 1.8 6.0 15* A -1.8 -2.0 -2.2 -1.2 1.0 7.7 -2.3 -0.5 -0.5 -0.9 -0.9 -0.8 15* D 0.0 12.7 0.0 10.4 0.0 13.4 0.0 1.6 0.0 6.7 0.0 4.3 Frame Column -----Dead-----Collateral- --=--Uve-------- Floor ------ Wind _Left1--Wtnd_Rightl- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 19 G 0.4 2.9 0.6 3.6 1.1 7.2 0.0 0.0 -7.7 -27.5 4.2 -19.5 19 A -0.4 2.1 -0.6 3.3 -1.1 6.5 -2.0 -0.2 11.6 -24.7 21.2 -14.6 19 D 0.0 9.7 0.0 11.9 0.0 23.8 2.0 100.1 0.0 -93.7 0.0 -58.2 Frame Column --Wind-Left2- -Wind-Right2- --Wind_Longl- --Wind-Long2- -Seismic-Left Seismic Una Una Horiz Vert Horiz Vert Hartz Vert Horiz Vert Horiz Vert -Right Horiz Vert 19 G -11.2 -14.6 0.7 -6.5 4.9 -30.4 6.5 -20.0 0.0 0.0 0.0 0.0 19 A -3.5 -15.2 6.1 -5.1 30.9 -23.2 24.8 -14.3 -0.6 0.0 0.6 0.0 19 D 0.0 -55.7 0.0 -20.2 OA . -92.3 0.0 -57.9 0.0 0.0 0.0 0.0 Frame Column -F5CRANEAI- -F5CRANEA2- F5PAT_LL_1- FSPAT_LI_2- -F5CRANEA3- -F5CRANEA4- Une Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 19 G 4.7 18.9 4.7 17.7 2.2 9.6 -1.1 -2.4 1.3 8.5 1.5 3.8 19 A -7.5 -2.5 -1.8 -2.1 -2.2 -1.2 1.0 7.7 -2.3 -0.5 -0.5 -0.9 19 D 0.0 11.9 0.0 12.7 0.0 10.4 0.0 13.4 0.0 1.6 0.0 6.7 Frame Column-F5CRANEA5- Une Una Horiz Vert 19 G 1.8 6.0 19 A -0.9 -0.8 19 D 0.0 4.3 OW1111W RIGID FRAME: BASIC COLUMN REACTIONS (k ) Frame Column ----- Dead -----Collateral- ----- Live -------- Floor ------ Wind_Leftt--Wind_Rightt- Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 20* G 0.4 2.9 0.6 3.6 1.1 7.2 0.0 0.0 -7.7 -27.5 4.2 -19.5 20* A -0.4 2.1 -0.6 3.3 -1.1 6.5 -2.0 -0.2 11.6 -24.7 21.2 -14.6 20* D 0.0 9.7 0.0 11.9 0.0 23.8- 2.0 100.1 0.0 , -93.7 0.o -58.2 Frame Column--Wind_Left2--Wind_Right2- --Wind_Longl- --Wind_Long2--Seismic-Left Seismic Line Line Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz -Right Vert 20* G -11.2 -14.6 0.7 -6.5 4.9 -30.4 6.5 -20.0 0.0 0.0 0.0 0.0 20* A -3.5 -15.2 6.1 -5.1 30.9 -23.2 24.8 -14.3 -0.6 0.0 0.6 0.0 20* D 0.0 -55.7 0.0 -20.2 0.0 -92.3 0.0 -57.9 0.0 0.0 0.0 0.0 Frame Column F7PAT_LL_1- F7PAT_LL-2- Una Una Horiz Vert Horiz Vert 20* G 2.2 9.6 -1.1 -2.4 20• A -2.2 -1.2 1.0 7.7 20• D 0.0 10.4 0.0 13.4 Frame Column ----- Dead -----Collateral - ----- Uve-------- Floor ------ Wind_Leftl- -Wind_Rightl- Une 23* Line Horiz G 0.4 Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 23* A -0.4 2.9 2.1 0.6 3.6 -0.6 3.3 1.1 7.2 -1.1 6.5 - 0.0 0.0 -2.0 -0.2 -7.7 -27.5 11.6 -24.7 4.2 21.2 -19.5 -14.6 23* D 0.0 9.7 0.0 11.9 0.0 23.8 2.0 100.1 0.0 -93.7 0.0 -58.2 Frame Column--Wind_Left2- -Wind_Right2=--Wind_Longl- --Wind'--Seismic Left Seismic Line Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Harz -Right Vert 23.5 -11.2 -14.6 0.7 -6.5 4.9 -30.4 6.5 -20.0 0.0 0.0 0.0 0.0 23* A -3.5 -15.2 6.1 -5.1 30.9 -23.2 24.8 -14.3 -0.6 0.0 0.6 ' 0.0 23* D 0.0 -55.7 0.0 -20.2 0.0 -92.3 0.0 -57.9 0.0 0.0 0.0 0.0 Frame Column-F8CRANEAI- -F8CRANEA2- F8PAT_LL_1- F8PAT_LL-2- -FBCRANEA3- -FBCRANEA4- Line 23* Una Horiz Vert Hartz Vert Horiz Vert Horiz Vert Hartz Vert Horiz Vert 23* G 4.0 A -6.9 17.7 -2.4 4.0 16.6 -1.2 -1.9 2.2 9.6 -2.2 -1.2 -1.1 -2.4 1.0 7.7 2.0 12.5 -3.4 -0.7 1.9 -0.4 4.6 -1.3 23* D 0.0 13.0 0.0 13.7 0.0 10.4 0.0 13.4 0.0 2.4 0.0 10.9 Frame Column -----Dead-----Collateral- ----- Live ------ Wtnd_Leftl--Wind_Rightl---Wind_Left2- Une 32 Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Hartz Vert Horiz Vert 32 G 0.5 A -0.5 3.4 2.1 0.8 3.7 -0.8 3.3 1.5 7.5 -1.5 6.5 -9.3 -28.5 13.2 -24.8 3.7 -19.8 21.6 -14.6 -12.5 -2.1 -15.5 -15.3 32 D 0.0 8.8 0.0 11.8 0.0 23.5 0.0 -92.6 0.0 -57.9 0.0 -54.8 Frame Column-Vtnd-Right2- --Wind-Longl- --Wtnd_Long2--Seismic-Left Seismic -F9CRNAM_1- Une 32 Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert -Right Horii Vert Horiz Vert G 0.5 -6.7 4.1 -30.9 6.2 -20.2 0.0 0.0 0.0 0.0 2.9 25.0 32 A 6.3 -5.1 31.8 -23.3 25.1 -14.3 -1.0 0.0 1.0 0.0 -5.5 -0.5 32 D 0.0 -20.0 0.0 -91.7 0.0 -57.7 0.0 0.0 0.0 0.0 =1.1 7.6 Frame Column-F9CRNAM-2- -F9CRNAM-3- -F9CRNAM_4--F9CRANEA5- -F9CRANE1k6- -F9CRANEA7- Une Una Horiz Vert Horiz Vert Hartz Vert Horiz Vert Horiz Vert Horiz Vert 32 32 G 3.7 A 24.6 0.6 7.6 1.4 7.2 5.3 18.6 5.3 17.4 2.6 12.9 -0.2 -0.1 -2.2 -0.2 3.1 0.3 -8.2 -2.3 -2.5 -1.8 -4.0 -0.7 32 D 0.2 7.6 -2.1 24.7 -0.8 24.6 0.0 12.1 0.0 12.8 0.0 2.0 Frame Column-F9CRANEAB- F9PAT_H I- . F91"AT_1 1 2- Une Line Horiz Vert Horiz Vert Hartz Vert 32 G 2.7 5.6 2.9 10.0 -1.4 -2.6 32 A -4.1 -1.6 -2.9 -1.2 1.4 7.7 32 D 0.0 10.1 0.0 9.9 0.0 13.6 Frame Column -----Dead-----Collateral- ----- Live ------ Wind_Leftt- -Wind-Rightl- --Wind_Left2- Line Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert Horiz Vert 33* 33* G 0.6 A -0.6 3.4 2.0 0.9 3.8 -0.9 3.2 1.8 7.6 -1.8 6.4 -10.6 -29.0 14.5 -24.5 3.3 -19.9 22.0 -14.5 -13.6 -1.0 -15.9 -15.1 33* D 0.0 8.4 0.0 11.8 0.0 23.5 0.0 -92.4 0.0 -57.9 0.0 -54.5 Frame Column-Wind_Right2- --Wind_Longl- --Wind_Long2- -Seismic-Left Seismic FIDCRNAM_t- Line Line Horiz Vert Horiz Vert Hartz Vert Horiz Vert -Right Hartz Vert Horiz Vert 33* G 0.3 -6.7 3.4 -31.1 5.9 -20.3 0.0 0.0 0.0 0.0 2.9 25.1 33* A 6.5 -5.1 32.5 -23.1 25.4 -14.2 -0.9 0.0 0.9 0.0 -5.5 -0.5 33* D 0.0 -20.0 0.0 -91.7 0.0 -57.8 0.0 0.0 0.0 0.0 -1.1 7.6 Frame Column F10CRNAM-2- F1OCRNAM_3- F1OCRNAM_4- FIOPATLL_1- F1OPATLL 2- Una Una Horiz Vert Horiz . Vert Horiz Vert Horiz Vert Hartz Vert 33* G 3.8 24.7 0.6 7.6 1.4 7.2 3.2 9.9 -1.4 -2.3 33* A -0.3 -0.1 -2.1 -0.2 3.0 0.3 -3.2 -1.5 1.4 8.0 33* D 0.2 7.5 -2.1 24.7 -0.8 24.6 0.0 10.4 0.0 13.1 Frame Column -----Dead-----Collateral- ----- Live ------ Wtnd-Leftl--Wind_Rightl- --Wtnd_Left2- Una Una Horiz Vert Horiz Vert Hartz Vert Horiz Vert Hartz Vert Horiz -Vert 35 35 G 0.3 A 2.1 0.4 2.0 0.8 3.9 -8.1 -20.8 2.5 -13.5 -9.8 -13.9 35 -0.3 D 0.0 1.6 5.6 -0.4 2.5 -0.8 5.8 -0.5 -27.7 24.1 -18.4 -8.5 -22.8 0.0 6.3 0.0 12.5 0.0 -70.3 0.0 -39.1 0.0 -50.3 Frame Column-Wtnd_Right2- --Wtnd_Longl---Wind_Long2- -Seismic-Left Seismic FIICRNAM_1- Line Una Horiz Vert Horiz Vert Horiz Vert Horiz Vert -Right Horiz Vert Horiz Vert 35 G 0.8 -6.6 0.9 -23.0 2.9 -13.5 0.0 0.0 0.0 0.0 2.7 23.6 35 A 16.0 -13.5 21.4 -26.1 15.3 -15.7 -0.8 -0.1 0.8 0.1 -5.3 -0.5 35 D 0.0 -19.1 0.0 -69.8 0.0 -39.5 0.0 0.0 0.0 0.0 -1.0 6.4 Frame Column F1ICRNAM-2- FIICRNAM_3- FIICRNAM_4- FI1PATLL_1- FIIPATLL-2- Une Una Horiz Vert Horiz Vert Hartz Vert Horiz Vert Horiz Vert 35 G 3.5 23.2 0.4 6.4 1.2 6.0 1.4 5.0 -0.6 -1.1 35 A -0.1 -0.1 -2.0 -0.2 3.2 0.3 -1.4 -0.9 0.6 4.3 35 D 0.3 6.3 -2.0 23.3 -0.7 23.2 0.0 5.8 0.0 6.7 2* Frame lines: 2 3 4 5 6 7 8 9 10 11 12 15• Frame lines: 15 16 17 18 20* Frame lines: 20 21 22 23• Frame lines: 23 24 25 26 27 28 29 30 31 33• Frame lines: 33 34 1, iiiiii1 4i5�ii� KEY PLAN E I FINAL ERECTION EXI FOR CONSTRUCTION E I FOR APPROVAL E I OTHER, EXPLAIN VULCAN STEEL STRUCTURES, INC VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 SSA C. 46 � No.88397p �= STATE 4F rY �-'%S/aIVAL*V�U ORIGINAL SIGNATURE REQUIRED DAVIS CONSTRUCTIFIN CRRP. IETAILS & DRAFT, vlo FORT PIERCE, FL 34946 /21 ANCHOR BOLTS NOTES MANUFACTURER RECOMMENDS USE OF STRAIGHT ROD ANCHOR BOLTS WITH NUT AND WASHER ON BOTH ENDS AS OPPOSED TO J-BOLTS OR ANCHOR BOLTS WITH HOOKS BECAUSE OF BETTER PERFORMANCE RESULTS IN CONCRETE FOUNDATIONS. THE TYPE OF BOLT USED FOR THE PROJECT SHALL BE DETERMINED BY THE FOUNDATION ENGINEER WITH THE BOLT STRENGTH MEEnNG OR EXCEEDING THAT OF AN ASTM F1554 GRADE 36 (MIN.) BOLT. ANCHOR BOLTS ANCHOR BOLT SUMMARY H/FLATHEX UT WAASHER SEE BUILDING PLANS FOR Diu P(in) PROJECTION CONCRETE LINE Qty Locate (in) Type z 048 Jamb 5/8" F1554 3.00 040 Endwall 3/4" F1554 3.00 -W' •• TOTAL LENGTH DETERMINED 0 156 Frame 3/4" ' F1554 3.00 BY FOUNDATION ENGINEER •• o X 136 Frame 1 F1554 4.00 W/FLAT WIASHEERR RECEIVED ANCHOR BOLTS SHALL BE ASTM F1554 GRADE 36 MIN. OR GRADE 55 APR 12 2011 850'-O'5TEEL LINE TO STEEL LINE 5 6 Pv4rmitting Department 27134-3 Si. LUd2 cour y 9 0 1 3 4 5 6 7 8 9 0 1 3 4 ( ) 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 20'-0" STEEL UNE- �I STEEL LINE Z � is _12'-0- io io '-0" io is 1 '-0" io is 12'-0" io 23'-8" 1-4 Low • Low Eave � 2' I "X-Bmcin 2" 2" 2" 2" 2" 2" "X-Bracin 2" 2° 2" 2" 2" 2" 2" 2" 2" "X-Bracin G io E E E E E E E E E E E E E E E F G E2 �+ H o n H � -6" C F c H of o o I H In 68 �+ -6• c z � I rl _ N m4 xIX O tL4' v I W ._j 13 - ' C m 83 I� o 0 I I � o in o (27134-2) " cq !-1 Z 8 cc B3 N 1 •-6" w H c o I I o 0 A3 in 04 w Z J _ U I (27134-1) 27134-2) r N SEE PLAN = OUT TO OUT CONCRETE Lj SEE PLAN W OUT TO OUT STEEL W W PROJECTION . . d1 . =•I e CONCRETE EDGE AND ANCHOR BOLT PRO ECRETE EDGE AND ANCHOR BOLT TInNN WALL PANEL 112 x 1 1/4' SDS INSIDE CLOSURE V/VASHER (6' aC) BASE ANGLE 2'x4'x16GA. 4' x STD. BASE TRIM • • 1/4' x A ()TR) 036'NAIL-IN ANCHOR 2 36' O.C. O)Y OTHERS) BASE ANGLE VITH BASE TROT AND BASE CLOSURES VIMTUT SHEETING NOTCH SLAB BEYON FINISHED FLOOR JAMB ➢EPTH SECTION 'A -A' 1-3/4' F.O,WIDTH 1-3/4' 7-'A-A' W ANCHOR BOLT PLAN NOTE: All Base Plates 0 100'-0" (U.N.) VISI❑NS �k = 1-3/4" KEY PLAN VULCAN STEEL STRUCTURES, INC VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 �� \GEtvs qW4 No.83970 .A• STATE OF =Q; \• '�(FR!ZED910-t ORIGINAL SIGNATURE R E I FINAL ERECTION PROJECT MAVERICK BOATS ANCHOR BOLT PLAN EX] FOR CONSTRUCTI❑N ID 27134-3 DESIGN�VLB DRAFTi vb E I FOR APPROVAL PROJECT FORT PIERCE, FL 34946 DATE,3/25/21 SHEET 1 1 NOT CONSTRUCTION ADDRESS Lcn0 1'-0 1 2" N m d* .4- DETAIL B Dia= 3/4" a m fn NIF 1 ��� z 251 DETAIL C Dia= 3/4" ® I l� o 4" " "�I 8 2 2" SW 4�,r-1 L D - Diu= 3/4" 8. I I �I01 4" o 0IIffi —I— 4- 2- U2„ 8" See Plan DETAIL E Dia= 3/4" N 1 I&Iffi 4" —�— 4- 2" 2- 8" See Plan DETAIL F Dia= 3/4" !$ I go 4" 2" 2" 8" DETAIL G Dia= 5/8" 0 a c F� M I O O I M N d DETAIL H Diu= 1 3- loll o I I I I a iq 4 1 /4" rn I� XIX 4" a 4„ 00 O I X I X L- — 2" SW _I— a SW 1 3/4„ 2^ 2" See Plan See Plan See Plan DETAIL N DETAIL M Dia= 1" o I I XIXch 3„ o I 4" X X d SW 2„ 2„ See Plan See Plan DETAIL J Dia= 1" I o I 5 1 /8" XX cn N 4" XIX a m 2^ 2^ d cn See Plan See Plan DETAIL K Dia= 1" o I I a d XIX a I I 4" X X as 2^ 2^ rn See Plan See Plan _ L Dia= 3/4" � I I W 3„ 2„ 2" 8„ DETAIL A3 Dia= 3/4" $„ o �I® 4„ 3„ 2„ 2, 8„ See Plan DETAIL B3 t0 ) / (2713 c�4-2)/ /��/// %2-MOWN C I FINAL ERECTION CXI FOR C❑NSTRUCTION C I FOR APPROVAL C I NOT C❑NSTRUCTION VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 •••••q�upnt'ppep��� SSA L.. ggti,,, EAjs No. 83970 .o STATE OF ORIGINAL SIGNATURE REQUIRED VULCAN STEEL STRUCTURES, INC RK DAVIS CONSTRUCTION CORP. PROJECT MAVERICK BOATS ANCHOR BOLT DETAILS ID 27134-3 DESIGN, VLB DRAFTi vlo I CHECKi JDR PROJECT FORT PIERCE, FL 34946 DATE,3/17/21 SHEET 2 OF 13 ADDRESS r • �- T COLUMN LINE H fv RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc._Bolt Base -Plate (in) Elev. Line Line City Diu Width Length Thick (in) E* 36 4 0.750 8.000 10.00 0.500 0.0 E• Frame lines: E A RIGID FRAME: ANCHOR BOLTS & BASE PLATES Frm Col Anc.-Bolt Base -Plate (in) Elev. Line Line Qty Dia Width Length Thick (in) C* 36 4 0.750 8.000 10.00 0.500 0.0 C* Frame lines: C B DESIGN LOAD DEFINITIONS RIGID FRAME: BASIC COLUMN REACTIONS (k ) Frame Column -----Dead-----Collateral- ----- Live ------ Wind-Leftl- -Wind-Rightt- --Wind-Left2- Line Line Horiz Vert Horiz Vert. Horiz Vert Horiz Vert Horiz Vert Horiz Vert E' 36 0.0 0.7 0.0 0.9 -0.3 4.0 1.2 -14.4 0.3 -8.1 1.4 -6.9 Cs 36 -0.1 1.1 0.0 1.6 -0.7 6.2 2.1 -23.9 0.4 -13.8 2.4 -10.0 Frame Column -Wind-Right2---Wind- --Wind-Long2- Line Line Horiz Vert Horiz Vert Horiz Vert E' 36 0.4 -0.6 -0.2 . -9.6 -0.2 -6.8 C* 36 0.7 0.1 -0.4 -15.6 -0.3 -11.7 E* Frame lines: E A CO Frame lines: C B BUILDING BRACING REACTIONS f Reactions(k ) Panel Shear -Wall - Col -Wind - -Seismic- (lb%ft) Lac Line Line Harz Vert Harz Vert Wind Seis Note L-EW E (h� F_SW 35 f R-EW A h B_SW 36 Torsional Bracing � Used f Bracing loads are applied to adjacent building h Rigid frame at endwall Wlnd_LI/Wind-Rl = Lateral wind load from the left/right with a negative Internal pressure coefficient. Wlnd_L2/Wlnd_R2 = Lateral wind load from the Left/right with a positive Internal pressure coefficient. Wind_Lnl = Longitudinal wind load with a negative Internal pressure coefficient. Wlnd_Ln2 = Longitudinal wind load with a positive Internal pressure coefficient. Selsmic_L/Selsmic_R = Lateral Seismic load from left/right. LWIND#_L#E/ LWIND#_R#E = Longitudinal wind loads for edge zones. F#UNB_SL_L/ F#UNB_SL_R = Unbalanced roof snow Load with wind from the left/right. F#PAT_LL # = Pattern live load for continuous beam systems. 'Note, Bracing reactions are not already Included in combination with any other load but must be added to basic reactions as desired by the foundation designer.' Collat = Collateral Load Endwall Load Case Definitlons Rafter Wind L/ Rafter Wlnd_R = Lateral wind load from the left/right. Brace Wlnd_L/ Brace Wlnd_R = Lateral wind Load from the left/right with the bracing loads added. Wind_P/Wind_S = Wind Pressure/Suction due to longitudinal wind. Wlnd_Ln# = Longitudinal wind load on the roof. Selsmlc_L/Selsmic_R = Lateral Seismic load from left/right. E#UNB_SL_L/ E#UNB-SLR = Unbalanced roof snow load with wind from the left/right. E#PAT_LL # = Pattern live load for continuous beam systems. LWIND#_L/LWIND#_R = Longitudinal wind loads for edge zones. REVISI❑NS GENERAL NOTES (1.) APPLICATION OF ENGINEERS SEAL IS FOR METAL BUILDING ONLY AND DOES NOT REPRESENT THE PROFESSIONAL OF RECORD. (2.1 FOUNDATION DESIGN AND CONSTRUCTION ARE NOT THE RESPONSIBILITY OF THE METAL BUILDING MANUFACTURER. (3.) ANCHOR BOLTS SHALL BE ACCURATELY SET TO A TOLERANCE OF +/- 1/8' IN BOTH ELEVATION AND LOCATION. 4.) THE BUILDING REACTION DATA REPORTS THE LOADS WHICH THIS BUILDING PLACES N THE FOUNDATION. THE FOUNDATION IS TO BE DESIGNED BY A QUALIFIED ENGINEER TO SUPPORT THE BUILDING REACTIONS IN ADDITION TO OTHER LOADS IMPOSED BY THE BUILDING USE OR OCCUPANCY WITH RESPECT TO JOB SITE CONDITIONS. (5.) ALL ANCHOR BOLTS TO BE ASTM F1554 GRADE 36 MIN. OR GRADE 55 (UNLESS NOTED) (6.) VALUES GIVEN FOR BENDS AND ANCHOR BOLT TOTAL LENGTHS ARE SUGESTED LENGTHS ONLY. IT IS THE RESPONSIBILITY OF THE FOUNDATION ENGINEER TO DETERMINE THESE VALUES SINCE THEY ARE A FUNCTION OF CONCRETE STRENGTH AS WELL AS OTHER FACTORS. (7.) WIND REACTIONS ARE BASED ON Vult. I I FINAL ERECTI❑N EX] FOR C❑NSTRUCTI❑N I I FOR APPROVAL I I OTHER, EXPLAIN VULCAN STEEL STRUCTURES, INC FORT PIERCE, FL 34946 VANESSA L. BANKS P.E. FLORIDA P.E.# 83970 500 VULCAN PARKWAY ADEL, GA 31620 `,•,.••`•SSA L. Qq''�•.,,. JP = ENS• o. 83 • STATE OF IDVk 'o,-,10NAL�ENto% Nzlla1 ORIGINAL SIGNATURE R1D RK DAVIS C❑NSTRUCTI❑N CORP. B I DRAFTi vb I CHECK. /21 SHEET 3