Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
APPROVED ENERGY LOT 20
FORM R405-2020 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: KHOV-EMERALD Builder Name: KHOVNANAIN HOMES Street: 5146 ARMINA PL. Permit Office: City, State, Zip: FORT PIERCE, FL, Permit !Number: Owner: EMERALD MODEL LOT 20 @ WATERSTONE Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 } 1. New construction or existing New (From Plans) 10. Wall TypeV508.8 sqft.) Insulation Area 2. Single family or multiple family Detached a- Frame - Wood, Exterior R=11.0 1180.70 ft2 3. Number of units, if multiple family 1 b. Concrete Block - int Insul, Exterior R=4A 973.39 ft2 c. Frame - Wood, Adjacent R=11.0 354.67 ft2 4. Number of Bedrooms 5 d. NIA R= ftZ 5. Is this a worst case? No 11. Ceiling Types (1354.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1354.00 ft2 6. Conditioned floor area above grade (ft2) 2321 b. NIA R= ft2 Conditioned floor area below grade (ft2) 0 c. NIA R= ft2 7. Windows(194.0 sqft.) Description Area 12. Ducts R ft2 a. U-Factor: Dbl, U=0.30 152.00 ft2 a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250 SHGC: SHGC=0.28 b. U-Factor: Dbl, U=0.55 42.00 ft2 13. Cooling systems ki3tulhr Efficiency SHGC: SHGC=0.34 a. Central Unit 46.5 SEER:16.00 c. U-Factor: NIA ft2 SHGC: Area Weighted Average Overhang Depth: 3 165 ft. 14. Heating systems kBtulhr Efficiency Area Weighted Average SHGC: 0.293 a. Electric Strip Heat 32.0 COP:1.00 8. Skylights Area c. U-Factor:(AVG) NIA ft2 15. Hot water systems SHGC(AVG): NIA a. Electric Cap: 50 gallons 9. Floor Types (1354.1 sqft.) Insulation Area EF:0.950 a. Slab -On -Grade Edge Insulation R=0.0 968.10 ft2 b. Conservation features b. Raised Floor R=11.0 386.00 ft2 None c. NIA R= ft2 16. Credits Pstat Glass/Floor Area: 0.084 Total Proposed Modified Loads: 70.47 PASS Total Baseline Loads: 71.88 1 hereby certify that the plans an specifications covered by Review of the plans and IlaE Sr4� 04 this calculation are in compliant with the Flo da En rgy specifications covered by this g Code. j calculation indicates compliance �j� with the Florida Energy Code. PREPARED BY: r ! Before construction is completed r"I DATE: this building will be inspected for + compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes.,%, with the Florida Energy Code. C'0 .� intt~ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 7/27/2021 12:33 PM EnergyGaugeO USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 6 FORM R405-2020 IN 011 ;HECKLIST REPORT PROJECT Title: KHOV-EMERALD Building Type: User Owner Name: EMERALD MODEL LOT 20 # of Units: 1 Builder Name: KHOVNANAIN HOMES Permit Office: Jurisdiction: Family Type: Detached New/Existing: New (From Plans) Comment: Bedrooms: 5 Conditioned Area: 2321 Total Stories: 2 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No CLIMATE Address Type: Lot # Block/Subdivision: PlatBook' Street: County: City, State, Zip: Street Address 5146 ARMINA PL_ St. Lucie FORT PIERCE, FL, / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 2321 19341.6 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 EXTRA SUITE 144 1267.2 No 2 5 1 No Yes Yes 2 EX SUITE BATH 60 528 No 0 1 No Yes Yes 3 FOYER 133 1173 No 0 1 No Yes Yes 4 GRT DIN KITCHEN 630 5544 No 1 1 No Yes Yes 5 BED 4 174 1392 No 1 1 No Yes Yes 6 BED 3 167 1334 No 1 1 No Yes Yes 7 BED 2 162 1296 No 1 1 No Yes Yes 8 HALL LOFT 350 2800 No 0 1 No Yes Yes 9 LAUNDRY 48 384 No 0 1 No Yes Yes 10 MASTER SUITE 224 1792 No 2 1 No Yes Yes 11 MAST WIC 60 476 No 0 1 No Yes Yes 12 MASTER BATH 104 832 No 0 1 No Yes Yes 13 HALL BATH 65 518 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio EXTRA SUITE 24 ft 0 144.8 W ---- 0 1 0 2 Slab -On -Grade Edge Insulatio EX SUITE BATH 6 ft 0 60 ft2 ---- ❑ 1 ❑ 3SIab-On-Grade Edge Insulatio FOYER 20.5 ft 0 133.3 ft2 ---- 1 0 0 4 Slab -On -Grade Edge Insulatio GRT DIN KITCHE 89 ft 0 630 ft2 __-- 0.5 0.5 0 7/27/2021 12:33 PM EnergyGaugeO USA 7.0.00 - FlaRes2020 FBC 7th Editlon (2020) Compliant Software Page 2 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Raised Floor BED 4 ---- --__ 174 ft2 11 0 0 1 6 Raised Floor BED 3 ---_ ____ 167 ft2 11 0 0 1 7 Raised Floor HALL LOFT ---- ---- 45 ft2 11 0 0 1 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch 1/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1466 ft2 0 ft2 Medium N 0.9 No 0.9 No 0 22.62 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1353 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BED 4 30 Blown 174 ft2 0.1 Wood 2 Under Attic (Vented) BED 3 30 Blown 167 ft2 0.1 Wood 3 Under Attic (Vented) BED 2 30 Blown 162 ft2 0.1 Wood 4 Under Attic (Vented) HALL LOFT 30 Blown 350 ft2 0.1 Wood 5 Under Attic (Vented) LAUNDRY 30 Blown 48 ft2 0.1 Wood 6 Under Attic (Vented) MASTER SUITE 30 Blown 224 ft2 0.1 Wood 7 Under Attic (Vented) MAST WIC 30 Blown 60 ft2 0.1 Wood 8 Under Attic (Vented) MASTER BATH 30 Blown 104 ft2 0.1 Wood 9 Under Attic (Vented) HALL BATH 30 Blown 65 ft2 0.1 Wood WALLS Adjacent To Wall TypeSpace Cavity Width Height Sheathing Framing Solar Below 1 E Exterior Concrete Block - Int InSEIXTRA SUIT 4.1 10 8 9 4 99.6 ft2 0 0 0.5 0 2 S Exterior Concrete Block - Int InsEIXTRA SUIT 4.1 11 8 10 0 116.7 ft2 0 0 0.5 0 3 S Exterior Concrete Block - Int InsEiX SUITE BA 4.1 5 5 10 0 54.2 ft2 0 0 0.5 0 4 E Exterior Concrete Block - Int InsuI FOYER 4.1 6 9 9 4 63.0 ft2 0 0 0.5 0 5 N Exterior Concrete Block - Int InsORT DIN KIT 4.1 17 5 9 4 162.6 ft2 0 0 0.5 0 6 S Exterior Concrete Block - Int InsGIRT DIN KIT 4.1 16 2 10 0 161.7 ft2 0 0 0.5 0 7 W Exterior Concrete Block - Int InsGRT DIN KIT 4A 33 10 9 4 315.8 ft2 0 0 0.5 0 8 N Exterior Frame - Wood BED 4 11 13 8 8 10 120.7 ft2 0 0 0.5 0 9 E Exterior Frame - Wood BED 4 11 10 11 8 10 96.4 ft2 0 0 0.5 0 10 E Exterior Frame - Wood BED 3 11 10 11 8 10 96.4 ft2 0 0 0.5 0 11 E Exterior Frame - Wood BED 2 11 10 11 8 10 96A ft2 0 0 0.5 0 12 S Exterior Frame - Wood BED 2 11 12 3 8 10 108.2 ft2 0 0 0.5 0 13 N Exterior Frame - Wood HALL LOFT 11 7 3 8 10 64.0 ft2 0 0 0.5 0 7/27/2021 12:33 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 3 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST RFPnPT WALLS Ornt9--V11 Adjacent Tr)Space Wall T�fpe Cavity Width Et In Height Pt In Area Sheathing Framing R-N/ah,e Fraction Solar Belo w Ah�-nr Grade% 14 S Exterior Frame - Woad HALL LOFT 11 12 9 8 10 112.6 ft2 0 0 0.5 0 15 N Exterior Frame - Wood MASTER SUI 11 13 2 8 10 116.3 ft2 0 0 0.5 0 16 W Exterior Frame Wood MASTER SUI 11 14 7 8 10 128.8 ft2 0 0 0.5 0 17 W Exterior Frame Wood MASTER SA 11 11 10 8 10 104.5 ft2 0 0 0.5 0 ,18 S Exterior Frame - Wood HALL BATH 11 10 0 8 10 88.3 ft2 0 0 0.5 0 19 W Exterior Frame - Wood HALL BATH 11 5 5 8 10 47.8 ft2 0 0 0.5 0 _20 W Garage Frame - Wood GIRT DIN KIT 11 38 0 9 4 354.7 ft2 0 0 0.5 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft in Ft In 1 E Insulated FOYER None .39 3 4 6 8 22.2 ft2 2 E Wood FOYER None .39 3 4 6 8 22.2 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 1 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 12 ft 0 in None None 2 W 7 Metal Double (Tinted) Yes 0.3 0.28 N 32.0 ft2 1 ft 0 in 12 ft 0 in None None 3 W 7 Metal Double (Tinted) Yes 0.55 0.34 N 42.0 ft2 11 ft 0 in 1 ft 0 in None None 4 E 9 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 It 0 in None None 5 E 10 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 6 E 11 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft' 1 ft 0 in 1 ft 0 in None None 7 N 13 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 8 S 14 Metal Double (Tinted) Yes 0.3 0.28 N 15.0 ft2 1 ft 0 in 1 ft 0 in None None 9 W 16 Metal Double (Tinted) Yes 0.3 0.28 N 30.0 ft2 1 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg, Wall Height Exposed Wall Insulation 1 386 ft2 386 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00037 2255.9 123.76 232.35 .1694 7 7/27/2021 1233 PM EnergyGaugefl USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 4 of 6 FORM R405-2020 INPUT SUMMARY CHFCKusT RFPnRT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 32 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 16 46.5 kBtulhr cfm 0.74 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / ---- Supply ---- ---- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 250 ft2 HALL LOFT 1 ft2 Default Leakage HALL LOFT (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan [ ]Feb Mar Heating �jJa,X] Feb 7C� Mar A r Apr Ma X Jun X Jul May Jun Jul Sep AuSep rl Aug ri Oct Nov Oct 7C� Nav Dec XDec Ventin Jan 11 Feb [X Mar [X] Apr May Jun Jul Aug Se Oct [X Nov [ j Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 76 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 BED 3 Default(8 lbslsq.ft. ft2 ft 0.3 POWDER Default(8 lbslsq.ft. ft2 ft 0.3 BATH 3 Default(8 lbslsq.ft. ft2 ft 0.3 WIC BED 3 Default(8 lbs/sq.ft. ft2 ft 0.3 SUITE 2 Default(8 lbs/sq.ft. ft2 ft 0.3 WIC BED 2 Default(8 lbs/sq.ft. ft2 ft 0.3 BATH BED 2 Default(8 lbs/sq.ft. ft2 ft 0.3 GALLERY 7/27/2021 12:33 PM EnergyGauge® USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 5 of 6 FORM R405-2020 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibslsq.ft. ft2 ft 0.3 LAUNDRY Default(8 Ibslsq.ft. ft2 ft 0.3 LIBRARY Default(8 Ibslsq.ft. W ft 0.3 DINING Default(8 lbslsq.ft. ft2 ft 0.3 KITCHEN Default(8 Ibslsq.ft. ft2 tt 0.3 CASUAL DINING Default(8 Ibslsq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibslsq.ft. ft2 ft 0.3 MASTER WIC Default(8 Ibslsq.ft. ft2 ft 0.3 MASTER BATH Default(8 Ibsls .ft. ft2 ft 0.3 MASTER SUITE 7/27/2021 12:33 PM EnergyGauge(D USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 6 of 6 FORM R405-2020 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPertormance Index, the more efficient the home. 5146 ARMINA PL., FORT PIERCE, FL, 1. New construction or existing New (From Plans) 10. Wall Type and Insulation Insulation Area 2. Single family or multiple family Detached a. Frame -Wood, Exterior R=11.0 1180.70 ftZ b. Concrete Block - Int Insul, Exterior R=4.1 973.39 ftz 3. Number of units, if multiple family 1 c. Frame - Wood, Adjacent R=11.0 354.67 ftZ 4. Number of Bedrooms 5 d. NIA R= ftz 5. Is this a worst case? No 11. Ceiling Type and insulation level Insulation Area a. Under Attic (Vented) R=30.0 1354.00 ftz 6. Conditioned floor area (ftZ) 2321 b. NIA R= ftz 7. Windows- Description Area c. NIA R= ftz a. U-Factor: Dbl, U=0.30 152.00 ftZ 12. Ducts, location & insulation level R W SHGC: SHGC=0.26 a. Sup: Attic, Ret: HALL LOFT, AH: HALL LOFT 6 250 b. U-Factor; Dbl, U=0.55 42.00 ftz SHGC: SHGC=0.34 13. Cooling systems kBtu/hr Efficiency c. U-Factor: NIA ftZ a. Central Unit 46.5 SEER:16.00 SHGC: d- N/A ftZ SHGC: SHGG: 14. Heating systems kBtulhr Efficiency Area Weighted Average Overhang Depth: 3.165 ft. a. Electric Strip Heat 32.0 COP:1.00 Area Weighted Average SHGC: 0.293 S. Skylights Description Area 16. Hot water systems a. U-Factor(AVG): NIA ftZ a. Electric Cap: 50 gallons SHGC(AVG): NIA EF: 0.95 b. Conservation features 9. Floor Types Insulation Area None a. Slab -On -Grade Edge Insulation R=0.0 968.10 ftZ Credits (Performance method) Pstat b. Raised Floor R=11.0 366.00 ftz c. NIA R= ftZ I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature. - Address of New Home: Date: City/FL Zip: .;tea 4 K� we *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida Energy Rating. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/27/2021 12:33 PM EnergyGauge@) USA 7.0.00 - FlaRes202O FBC 7th Edition (2020) Compliant Software Page 1 of 1 oa Project Summary Entire House Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: wwwAndstromair.com Proilect Information For: KHOVNANIAN HOMES Notes: LOT 20 EMERALD MODEL Desicin Information Weather: Winter Design Conditions Outside db 42 OF Inside db 70 °F Design TD 28 OF Heating Summary Structure 21178 Btuh Ducts 3754 Btuh Central vent (108 cfm) 3336 Btuh Outside air Humidification 0 Btuh Piping 0 Btuh Equipment load 28269 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heating Coolie Area (ftZ 2321 23N Volume (ft3) 19343 19343 Air changes/hour 0.32 0.16 Equiv. AVF (cfm) 103 52 Heating Equipment Summary Make CARRIER Trade Model 10 KW AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 7.6 kW 25981 Btuh 15 OF 1600 cfm 0.064 cfm/Btuh 0 in H2O Job: Date: 6-2021 By: LINDSTROM Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 22956 Btuh Ducts 7217 Btuh Central vent (108 cfm) 1787 Btuh Outside air Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 30362 Btuh Latent Cooling Equipment Load Sizing Structure 3755 Btuh Ducts 2153 Btuh Central vent (108 cfm) 4529 Btuh Outside air Equipment latent load 10437 Btuh Equipment Total Load (Sen+Lat) 40799 Btuh Req. total capacity at 0.74 SHR 3.4 ton Cooling Equipment Summary Make CARRIER Trade Cond CA16NA048 Coil FX4DNF049 AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 34200 Btuh 12300 Btuh 46500 Btuh 1600 cfm 0.053 cfm/Btuh 0 in H2O 0.75 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft`° 2021-Jul-27 12.43 42 Right -Suite® Universal 2019 19-0,12 RSU08398 Page 1 ` ...OJECTS FNERGYIA- MANUAL JWHOV-EMERALD-PSTL.rup Calc = MJ8 Front Door Faces: N Right-JO Worksheet Job: Entire House pate: 6-2021 _ Lindstrom Air Conditioning By: LINDSTROM 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www,lindstromaircom 1 Room name Entire House EXTRA SUITE 2 Exposed wall 145.0 ft 24.0 ft 3 Room height 8,3 ft 8.8 ft heat/cool 4 Room dimensions 11.0 x 13.2 ft 5 Roorn area 2321,0 ft2 144.8 ft2 Ty Construction U-value Or HTM Area (ftj Load Area (ft� Load number (Btuhfft�k- °F) (BtutVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coal Gross NIPIS Heat Cool Gross N/P/S Heat Cool 6 12B-Osw 0.097 n 2.72 2.34 300 285 774 666 0 C 0 0 1 D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 n 24.36 22.27 15 0 365 334 0 0 0 0 w 13A-4ocs 0.143 n 4.00 2.19 162 162 649 354 0 0 0 0 11 1213-0sw 0.097 e 2.72 2.34 288 243 660 568 0 0 0 0 1 D-h2om 0.870 e 0.00 0.00 0 0 0 0 0 0 0 0 1D-h2om 0.870 e 24.36 55.33 45 0 1096 2490 0 0 0 0 W 13A-4ocs 0.143 e 4.00 2.19 143 1D6 424 232 99 84 336 184 L-GD, 1D-h2om 0.870 e 24.36 55.33 15 6 365 830 15 0 365 830 11 DO 0.390 a 1092 10.34 22 22 240 227 0 0 0 0 1213-0sw 0.097 s 2.72 2.34 308 293 796 686 0 0 0 0 1D-h2om 0.670 s 0. cc 0.0C 0 0 0 0 0 0 0 0 10-12om 0,870 s 24.36 22.27 15 30 365 334 0 0 D 0 w 13A-4ocs 0.143 s 4.00 2.19 333 333 1333 720 117 117 468 256 1213-0sw 0.097 w 2.72 2.34 280 250 679 584 0 0 0 0 1D-h2om 0.870 w 0.00 0.00 C 0 0 0 0 0 0 0 1D-h2om 0.870 w 24.36 55.33 30 0 731 1660 0 0 0 0 13A-4ocs 0.143 w 4.CC 2.19 315 241 965 527 0 0 0 0 1➢-h2om 0.870 w 0.00 0.00 C 0 D 0 0 0 0 0 1D-h2om 0.870 w 24.36 55.33 32 0 780 1771 0 0 0 0 10-h2omd 0.870 w 0.00 0.00 C 0 0 0 0 0 0 0 1D-h2ornd 0.870 w 24.36 22.27 42 84 1023 936 0 0 0 0 F� 1213-0sw 0.097 2.72 1.33 347 325 883 432 0 0 0 0 11 DO 0.390 n 10.92 %34 22 22 240 227 0 0 0 0 C 1613-30ad 0.032 a 0.90 1.60 1353 1353 1212 2165 0 0 0 0 F 19A-1lbscp 0.073 - 1.45 0.78 386 386 559 299 0 0 0 0 F 22A-tpl 0.989 - 27.69 0.00 968 140 3863 0 145 24 665 0 6 c) AED excursion 1215 -66 Envelopelosslgain 18004 17266 1835 1184 12 a) Infiltration 3176 850 322 86 b) Room ventilation 0 0 0 0 13 Irrtemal gains: Occupants @ 230 8 1840 2 460 Applianceslother 3000 0 Subtotal (lines 6 to 13) 21178 229956 2157 1730 Less extemal load 0 0 C 0 Less transfer 0 0 C 0 Redistribution 0 0 C 0 14 Subtotal 21178 22956 2157 173C 15 Duct loads 18% 31% 3754 7217 -0% 0% 0 0 Total room load 24932 30173 2157 1730 Air required (ofm) 1600 1600 138 92 Calculations aperoved by ACCA to meet all requirements of Manual J 8th Ed. �� wwYghtsoit^ ��� ^�•-^•° °•�-�_-�^^•• Right -Suite® Universal 2019 19.0.12 RSD06398 2021-Jul-2712:43:42Page 1 ...OJECTS ENERGYIA- MANUAL JWHOV-EMERALD-PSTL.rup Calc = MJ8 Front Door faces: N Right-J® Worksheet Job: w Entire House Date: 6-2021 Lindstrom Air Conditioning By: LINDSTROM 3601 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954.420-0064 Web: www.lindstromair.com 1 Room name EX SUITE BATH FOYER 2 Exposed wall 6.0 ft 26.0 ft 3 Room height 8.8 ft heaUccoi 8.8 ft heat/cool 4 Room dimensions 10.0 x 6.0 ft 20.5 x 6.5 ft 5 Room area 60.0 ft' 133.3 ft' Ty Construction U-value Or HTM Area (w) Load Area (ft2) Load number (Btuhlft2 °F) (Btuh w) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat cool Gross N/P/S Heat Coal 6 1213-Osw 0.097 n 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0870 n 1 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 n 24.36 22.27 D 0 0 0 0 0 0 0 W 13A4ocs 0,143 n 4.00 2.19 0 0 0 0 0 0 0 O 11 VL212B-Osw 0.097 e 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0,870 e 24.36 55.33 0 0 0 0 0 0 0 0 13A-4ocs O.143 e 4,00 2.19 0 0 0 0 44 22 88 48 1 D-h2om 0.870 e 24.36 5533 0 0 0 0 0 0 0 0 11DO 0.390 a 10.92 10,34 0 0 0 0 22 22 240 227 W 12B-0sw 0.097 s 2.72 2,34 0 0 0 0 0 0 0 0 1D-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 1D-h2om 0.870 s 24.36 22.27 0 0 0 0 C 0 0 0 W 13A-4ots 4143 s 4.00 219 54 54 216 Il a 0 0 0 0 12B-0sw 0.097 w 2,72 2.34 0 0 0 0 0 0 0 0 ID-h2cm 0.870 w 0,00 0.00 0 0 0 0 0 0 0 0 1D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0. S70 w 0.00 0. DO 0 0 0 0 0 0 0 0 ID-h2cm 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 1D-h2omd 0.870 w 0,00 0. co 0 0 0 0 0 0 0 0 1D-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0 R 12B-0sw 0.097 - 2.72 1.33 0 0 0 0 185 185 502 246 D 11 DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 c 1613-39ad 0.032 e 0.90 1.60 0 0 0 0 0 0 0 0 F 19A-llbsop 0.073 1.45 0.78 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0_00 60 6 166 0 133 21 568 0 6 c) AED excursion -12 46 Envelope losslgain 362 lob 1398 475 12 a) Infiltration 81 22 65 18 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 463 12B 1464 493 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 463 128 1464 493 15 Duct Loads -0% 0% 0 0 -0% 0% 0 0 Total room load 463 128 1464 493 Air required (ofm) 30 7 94 26 Calculations approved by ACCA to rneet all requirements of Manual J 8th Ed. wrigl�tspf�� �^�A - •° -•• _M., Right -Suite® Universal 2019 19.0.12 RSU08398 2021-Jul-2712:43:42Page 2 OJECTS ENERGYIA- MANUAL JIKHOV-EMERALD-PSTL.mp Calc = MJ6 Front Doorfaces: N Right-J® Worksheet Joe: Entire House Date: 6-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromalr.com 1 Room name GIRT DIN KITCHEN BED 4 2 Exposed wall 89 0 ft 0 ft 3 Room height 8.8 ft heat/cool 8.0 ft heaUccol 4 Room dimensions 35.0 x 18.0 ft 12.0 x 14.5 ft 5 Room area 630.0 ' ft 174.0 ft2 Ty Construction U-value Or HTM Area (ftz) Load Area {ft�} Load number (Btuhlft2 °F) (B fit) or perimeter ft (} (Btuh) or perimeter {ft} (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P1S Heat Cool 6 V6 12B-0sw 0.097 n 2.72 2,34 0 0 0 0 120 120 326 281 1 D-h2om 0. 870 n 0, 00 0,00 0 0 0 0 O 0 0 0 1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 C 0 0 0 w 13A-4ocs C.143 n 4.00 2.19 162 162 649 364 0 0 0 0 11 0.097 e 2,72 2.34 0 0 0 0 96 81 220 169 T�1213-0sw 1 D-h2om 0.870 e 0, 00 0,00 0 p 0 0 0 0 0 0 1 D-h2om 0. a70 e 24.36 5E 33 0 0 0 D 15 0 365 830 13A-4ocs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om C.870 e 24.36 55.33 0 0 0 0 0 0 0 0 11DO 0.390 e 10.92 10.34 0 0 0 0 0 0 0 0 w 12B-0sw 0.097 5 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.870 s 0.00 0. C0 0 0 0 0 0 0 0 0 1D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 s 4.00 2,19 162 102 649 354 0 0 0 0 12B-Osw 0.097 w 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 315 241 965 527 0 0 0 0 1D-h2om 0.870 w 0,00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24,36 55.33 32 0 780 1771 0 0 0 0 1 D-h2omd 0.870 w 0.00 0.00 C 0 0 0 0 0 0 0 1 D-h2omd 0.870 w 24.36 22.27 42 42 1023 936 0 0 0 0 1213-0sw 0.097 - 2.72 1.33 162 140 390 186 0 b 0 0 11 DO 0.390 n 10.92 10.34 22 22 24C 227 0 0 0 0 C 1613-30ad 0.032 a 0-90 1.60 C 0 0 0 174 174 156 278 F 19A-llbscp 0.073 - 1.45 0.78 0 0 0 0 174 174 252 135 F 22A-to[ 0.989 - 27.69 0.00 63C 89 2465 0 0 0 0 0 6 c) AED excursion 1539 -1G4 Envelope loss/gain 7150 5895 1319 1609 12 a) Infiltration 953 255 322 86 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 23D 1 230 1 230 Applianceslother 1800 0 Subtotal (lines 6 to 13) 8103 8180 1641 1926 Less external load 0 C 0 C Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 8103 8180 1641 1926 15 Duct loads -0% ❑% 0 0 42% 581/o 685 1118 Total room load 8103 81801 2327 3044 Air required (cfm) 520 434 149 161 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr�ghtsoft 2021-Jul-27 12:43:42 Right-Suite® Universal 2019 19.0.12 RSUCa398 Page 3 ...OJECTS ENERGYIA- MANUAL JSKHOV-EMERALD-PSTL.rup Catc = MJ8 Front Door faces: N RWMW Right-3® Worksheet Job: Entire House Date: 6-2021 _-_ By: LENDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: wwwAriostromair.com 1 ROom name BED 3 BED 2 2 Exposed wall 0 It 0 ft 3 Room height 8.0 ft heaticool 8.0 ft heaticool 4 Room dimensions 11.5 x 145 ft 12.0 x 13.5 ft 5 Room area 166, 8 ft2 162.0 ft' TY Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuh/Wt T) (Btuhlft2) or perimeter (tt) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N!P!S Heat Cool Gross NIPIS Heat Co01 6 12B-0sw 0.097 n 2.72 2,34 0 0 0 0 0 0 0 0 1D-h2om 0.870 n O.CO 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 0 W 13A-4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 11 \612B-Osw 0.097 e 2.72 2.34 96 81 220 189 96 81 220 189 1 D-h2om 0.870 a 0. co 0.00 0 0 0 0 0 0 0 0 1D-h2om 0.870 e 24.36 55.33 15 0 365 830 15 G 365 830 13A-40cs 0.143 e 4.00 2.19 0 0 0 0 0 0 0 0 1D-h2om 0.670 e 24.36 55.33 0 0 C 0 0 0 0 0 1f D0 0.390 e 10.92 10,34 0 a G 0 0 0 0 0 V11 1213-0sw 0.097 s 2.72 2.34 0 0 0 0 108 108 293 252 Lt 1113-h2om 0.870 s 0.00 0.00 0 C 0 0 0 0 C 0 ID-h2om 0.670 s 24.36 22.27 0 0 0 0 0 0 a 0 W 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 C 0 L�J 12B-0sw 0.097 w 2.72 2.34 0 0 0 0 0 0 0 0 'ID-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 w 24.35 55.33 0 0 0 0 0 a 0 a 13A- flocs 0.143 w 4. DD 2.19 0 0 0 0 C 0 0 0 ID-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 ID-h2om 0.870 w 24.36 55.33 0 0 D 0 0 0 0 0 ID-h2omd 0.870 w 0.00 0.00 0 0 0 0 0 a 0 0 1 D-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0 T-D i 2B-Osw 0.097 - 2.72 1.33 0 0 0 C 0 0 0 0 i 1 DO C.390 n 10.92 10.34 0 0 0 0 0 0 0 0 C 16B-30ad 0.032 e 0.90 1.60 167 167 149 267 162 162 145 259 F 19A-11bscp 0.073 1.45 0.78 157 167 242 130 0 a 0 0 F 22A-tl)l 0.989 27.69 0.00 0 0 0 0 b 0 0 0 6 c) AED excursion -74 -88 Envelope loss/gain 977 1341 1024 1443 12 a} Infiltration 143 38 304 81 b) Room vent anon 0 0 0 0 13 Intemal gains' Occupants @ 230 1 230 1 230 Appliances/other 0 D Subtotal (iines 6 to 13) 1120 1610 1328 1755 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 a G 14 Subtotal 1120 1610 1328 1755 15 Duct loads 42% 58% 468 935 42% 58% 556 1019 Total room load 1587 2545F 1883 2774 Air required {cfm} 102 135 121 1 77 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -fig- 2021-Jul-27 12:43:42 a Right -Suite@ Universal 2019 19.0.12 RSU08398 Page 4 OJECTS ENERGYtiA- MANUAL J1KH01FEMERALD-PSTL.rup Cale = MJ8 Front Door faces: N OPRawaW Right-JO Worksheet Job: •-• Entire House Date: 6-2021 By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420.0064 Web: www.lindstromair.com 1 Room name HALL LOFT LAUNDRY 2 Exposed wall 0 ft 0 ft 3 Room height 8.0 ft heaticool 8-0 ft heat/cool 4 Room dimensions 35.0 x 10.0 ft Ro x 6.0 ft 5 Room area 350.0 ft' 48.0 ft' Ty Construction U-vaiue Or HTM Area (W) Load Area (ftz ) Load number (B1uhlft2 °F) (Btuhlft� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Gross N/PIS Heat Cool Gross NIPIS Heat Cool Heat Ccol 6 126-0sw 0,097 n 2.72 2.34 64 49 133 115 0 0 0 0 1 D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 01 0 0 1 D-h2om 0.870 n 24.36 22.27 15 0 365 334 0 0 0 0 w 13A4ocs 0.143 n 4.00 2.19 0 0 0 0 0 0 0 0 11 12B-Osw 0,097 e 2-72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.670 e 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 24.36 55,33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 e 4.00 219 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 2436 56.33 0 0 0 0 0 0 0 0 11 DO 0.390 e 1092 10,34 0 0 0 0 0 0 0 0 w 12B-Osw 0.097 s 2,72 2,34 112 97 263 227 0 0 0 0 1 D-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 ❑ 0 1 D-h2om 0.870 s 24.36 22.27 15 15 365 334 0 0 0 0 w 13A-4ocs 0.143 s 4.00 2,19 0 0 0 0 0 0 ❑ 0 128-0sw 0.097 w 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0. &70 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 1D-h2omd 0.870 w 0.00 ❑_00 0 0 0 0 0 0 0 0 1D-h2omd e_870 w 24.36 22.27 0 0 0 0 0 0 0 0 1213-0sw 0.097 - 2.72 1-33 0 0 0 0 0 0 0 0 11DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 a 0.90 1.60 350 350 314 560 48 48 43 77 F 19A-1lbscp 0.073 1.45 0.78 45 45 65 35 0 0 0 0 F 22A-tol 0.989 - 27.69 0,00 0 0 0 0 0 0 0 0 6 c) AFD excursion -144 -110 Envelope loss/gain 1506 1461 43 -33 12 a) Infiltration 262 70 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 p 0 0 Applianceslother 0 1200 Subtotal (lines 6 to 13) 1769 1531 43 1167 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1769 1531 43 1167 15 Duct loads 42% 56% 738 889 42% 58% 18 678 Total room load 2507 2420 61 1645 Air required (cfm) 161 128 4 98 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fj-F- 2021-Jul-2712:43A2 A - �-••^ Right -Suite® Universal 2019 19.0.12 RSUG8398 Page 5 ...OJECTS ENFRGYIA- MANUAL JIKHQV-EMERALD-PSTL.rup Calc - MJ8 Front Doer faces: N Right-J® Worksheet Job: Entire House Date: 6-2021 ... Lindstrom Air Conditioning By: LINDSTROM 3531 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 964-420-0064 Web: www.lindStroMaiT..com 1 Roam name MASTER SUITE MAST WIC 2 Exposed wall ❑ It 0 n 3 Room height 8.o ft heat/cool 8.0 ft heat/cool 4 Room dimensions 16.0 x 14.0 ft 8.5 x 7.0 ft 5 Room area 224.0 ft' 59.5 ft' Ty Construction U-value Or HTM Area (ft'} Load Area (ft2) Load number {Btui (Btuhlft'} I or perimeter (ft) (Btuh) or perimeter (ft) (Btuh ) Gross NIPIS Heat Cool Gross NIP1S Heat Cool Heat Cool 6V[_:2 1213-0sw 0-097 n 2.72 234 116 116 315 271 0 0 0 0 1 D-h2om 0.870 n 0.00 0.00 0 0 0 0 0 0 0 0 1D-h2om 0-870 in 24.36 22.27 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 in 4.00 2.19 0 0 0 0 0 0 0 0 11 121 0.097 e 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.670 e 0.00 0.00 0 0 0 0 0 0 0 0 1D-h2om 0.870 e 24.36 55,33 0 0 0 0 0 0 0 0 13AAocs 0-143 e 4.00 2,19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 24.35 55.33 0 0 0 0 0 0 0 0 11 DO 0.390 e 10.92 10.34 0 0 0 0 0 0 0 0 w1 _ 12B-Osw 0.097 s 2,72 2.34 0 0 0 0 0 0 0 0 1 D-h2om 0.870 s 000 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 s 24.36 22.27 0 0 0 0 0 0 0 0 w 13A-4ocs 0-143 s 4.00 2.19 0 0 0 0 0 0 0 0 121 0.097 w 2.72 2.34 128 98 206 229 0 0 0 0 1 D-h2om 0.870 w 000 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 30 0 731 1660 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 ❑ 0 1 D-h2om C.870 w 0.00 0.010 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 1 D-h20md & B70 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2omd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0 12B-Osw 0.097 - 2.72 1.33 0 0 0 0 0 0 0 0 11DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 C 161 0.032 a 0.90 1.60 224 224 201 358 60 60 53 95 F 19A-11 i 0.073 - 1.45 078 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 - 27.69 0.W 0 0 0 0 0 0 0 0 61 c) AED excursion 427 -8 Envelope losslgain 1513 2946 53 87 12 a) Infiltration 354 97 0 ❑ b) Room ventilation 0 0 0 0 13 Internal gains: Occupants (g 230 2 460 ❑ 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 1B77 3503 53 87 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1B77 3503 53 87 15 Duct loads 42% 58% 784 2035 42% 58% 22 51 Total room load 2660 5538 76 138 Air required {cfm) 171 294 5 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w rigl �tsoi'[w 2021-Jul-27 12:43:42 M.. Right -Su te® Universal 2019 19.0.12 RSU08398 Page 6 ...OJECTS ENERGYIA- MANUAL AKFICIFEMERALD-PSTL.rup Cali = i Front Door faces: N RiOW@ Worksheet Job. Entire House Date: 6-2021 zz By: LINDSTROM Lindstrom Air Conditioning 3581 W MCNAB RD, POMPANO BEACH, FL 33069 Phone: 954-421-4117 Fax: 954-420-0064 Web: www.lindstromaif.corn 1 Room name MASTER BATH HALL BATH 2 Exposed wall 0 ft 0 ft 3 Room height S.0 ft heat/cool 8,0 ft heat/cool 4 Room dimensions 8.0 x 13.0 ft 11.0 x 5.9 ft 5 Room area 104.0 W 64.8 ft2 Ty Construction U-value Of HTM Area (W) Load Area (fV) Load number (Btuhlft2 °F) (BtuhlW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gress NIPIS Heat Cool Gross NIPIS Heat Ccol 6 V6 1213-Osw 0,097 n 2.72 2.34 0 0 0 0 0 0 0 0 1 D-h2om O.870 n aw 0.00 0 0 0 0 0 p 0 p 1 D-h2om 0.870 n 24.36 22.27 0 0 0 0 0 0 0 p W 13A-4ocs 0.143 n 4.00 2,19 0 0 0 0 0 0 0 0 11 12B-osw 0.097 e 2.72 234 0 0 0 0 0 0 0 0 1 D-h2om 0, 870 e 0.00 000 0 0 0 0 0 0 0 0 1 D-h2om 0.870 e 24.36 5533 0 0 0 0 0 0 0 0 13A-40cs 0.143 e 4,00 2.19 0 0 0 0 0 0 0 0 1D-h2om 0.870 e 24,36 55.33 0 0 0 0 0 0 0 0 11 DO 0.390 a 1092 10.34 0 0 0 0 0 0 0 0 W 12B-Osw 0.097 s P.72 2.34 0 0 0 0 88 88 239 206 1D-h2om 0.870 s 0.00 0.00 0 0 0 0 0 0 0 0 1D-h2orn 0.87p s 24,36 22.27 0 0 0 0 0 0 0 0 w 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 1213-Osw 0.097 w 2.72 2.34 104 104 282 243 48 48 130 112 1D-h2om 0.870 w 0.00 0.00 0 0 0 0 0 0 0 0 1 D-h2om 0. a70 w 24.36 55,33 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 1 D-h2om 0.870 w 0.00 0. co 0 0 0 0 0 0 0 0 1D-h2om 0.870 w 24.36 55.33 0 0 0 0 0 0 0 0 1D-h2omd 0.870 w 0.00 O.CO 0 0 0 0 0 0 0 0 1D-h2cmd 0.870 w 24.36 22.27 0 0 0 0 0 0 0 0 126-05w 0.097 - 2.72 1.33 0 0 0 0 0 0 0 0 11DO 0.390 n 10.92 10.34 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 a 0.90 1.60 104 104 93 166 65 65 58 104 F 19A-llbscp 0.073 1.45 0.78 0 0 0 0 0 0 0 0 F 22A-tpl 0.989 27.69 0.00 C 0 0 0 0 0 0 0 6 c) AED excursion _39 -41 Envelope loss/gain 376 371 427 381 12 a) Intiltration 155 42 203 54 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 Q 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 531 412 630 435 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 531 412 030 435 15 Duct loads 42% 58% 222 239 42% 58% 263 253 Total roam load 752 652 893 688 Air required (cfm) 48 35 57 36 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed wrightsol`t® 2021-Jul-2712:43:42 �,�A �wM Right-Sude* Universal 2019 19.0.12 RSUG8398 Page 7 ...OJECTS ENERGYtA- MANUAL J\KHOV-EMERALD-PSTL.rup Calc =MJB Front Deorfaces: N