HomeMy WebLinkAboutFL3607-A0_05-28-21(1)C INDEX OF SHEETS: ARCHITECTURAL AO COVER SHEET / CODE ANALYSIS STRUCTURAL ELECTRICAL 57N REMODEL C1 SITE PLAN S0.1 GENERAL NOTES E1 POWER PLAN / DETAILS D1 DEMOLITION PLAN S0.2 EXISTING ROOF FRAMING PLAN E2 POWER POLES / PLAN / NOTES Al FLOOR PLAN / NOTES / DETAILS E2.1 DOOR ALARM / EAS A2 DOOR SCHEDULE / DETAILS MECHANICAL E3 LIGHTING PLAN / DETAILS A3 EXTERIOR ELEVATIONS / NOTES MI HVAC ROOF PLAN / DETAILS E4 PANEL SCHEDULES / DETAILS A4 INTERIOR ELEVATIONS / DETAILS M 1.1 HVAC PLAN / DETAILS E5 VENSTAR CONTROLS A5 FIXTURE PLAN / DETAALS E6 VENSTAR DETAILS TENANT FINISH OUT A6 REFLECTED CEILING PLAN / DETAILS PLUMBING P1 PLUMBING PLANS / DETAILS DESIGN PARAMETERS LOCATION MAP FIRE CODE & LIFE SAFETY NOTES: PROJECT SUMMARY DESIGN CODES: 2020 FLORIDA BUILDING CODE OCCUPANCY CLASSIFICATION: GROUP M (MERCANTILE) 1. EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL TYPE OF CONSTRUCTION: II—B SPRINKLED KNOWLEDGE OR EFFORT, EXCEPTION: MAIN EXIT DOOR HAS KEY LOCKING HARDWARE. G.C. SHALL PROVIDE A SQUARE FOOTAGE: 7343 SQ ET NUMBER OF STORIES: 1 ALLOWED / 1 SHOWN n 4 READABLE, DURABLE SIGN, ON OR ADJACENT TO THE EXIT DOOR, STATING "THIS DOOR TO REMAIN UNLOCKED �,n F�1�fW 1 Uj WHEN THE BUILDING IS OCCUPIED", SIGN TO BE ONE INCH HIGH LETTERS ON A CONTRASTING BACKGROUND, BUILDING AREA. UNLIMITED ALLOWED / 7343SF SHOWN Lakewood TENANT FLOOR LEVEL: ONE AREA INCREASE: UNLIMITED Park � w aif 2. MAINTAIN ONE HOUR FIRE RESISTIVE WALL CONSTRUCTION AT BUILT—IN FIXTURES SUCH AS FIRE BUILDING HEIGHT: 19, f EXTINGUISHER CABINETS, AND ELECTRICAL PANELS EXCEEDING 16 SQUARE INCHES IN AREA, SPRINKLED: YES L•7 FJ �. 3. A MINIMUM OF ONE 2A1OBC CLASSIFICATION FIRE EXTINGUISHER SHALL BE PROVIDED WITHIN 75' TRAVEL ' LL DISTANCE FOR EACH 6,000 SQ,. FT, OR PORTION THEREOF ON EACH FLOOR, TO BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. CONSTRUCTION TYPE: II—B EXITING ANALYSIS r� lvBanyan St OCCUPANCY TYPE: M —MERCANTILE (EXISTING) 4, BUILDING ADDRESS LETTERS SHALL BE LOCATED ON BUILDING EXTERIOR IN ACCORDANCE WITH THE CITY OCCUPANT LOAD: 122 PERSONS OCCUPANT LOAD FOR EGRESS: San Carlos ar. MUNICIPAL CODE. ADDRESS NUMERALS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. jam" Rd � ����� �+ 5, CONTRACTOR TO SECURE ALL PERMITS REQUIRED BY THE FIRE PREVENTION BUREAU PRIOR TO NUMBER OF EXITS: 2 MERCANTILE: 7343SE / 60 = 122 PERSONS Mira l,ar Ave M I�r:,r�:,,� -Vir-, �°•��o� t�lne5 CIr OCCUPANCY OF THIS BUILDING. BUILDING CODE: 2020 FLORIDA BUILDING CODE ailk 6. EXIT SIGNS ARE REQUIRED FOR ALL EXITS SERVING AN OCCUPANT LOAD EXCEEDING 50. SEE ELECTRICAL LIFE SAFETY CODE: NFPA 101 EXITS: y a DRAWINGS FOR LOCATIONS. MECHANICAL CODE: 2020 FLORIDA MECHANICAL CODE 2 EXITS REQUIRED FOR OCCUPANT LOAD > 50 4894 N Ya ELECTRICAL CODE: 2018 NEC ������ �� Ki��� H viry 7. INTERIOR FINISHES TO HAVE A FLAME SPREAD RATING OF 25 OR LESS. EXIT WIDTH 122 OCCUPANTS X .2 = 24.4 IN REQUIRED rrndrlia Rd Indrlo Rd ln�dr�rt� i r, ,rl PLUMBING CODE: 2020 FLORIDA PLUMBING CODE 8. FLAMMABLE AND COMBUSTIBLE MATERIAL WILL NOT EXCEED THE MAXIMUM ALLOWED UNDER TABLE MINIMUM = 72 I N . PROVIDED711 3404.3.4.1 OF THE IFC OR TABLE 7902.5—B OF THE UFC. THERE WILL BE NO HIGH PILED STORAGE AS LOCAL CODE AMENDMENTS: N/A ,L1 DEFINED BY EITHER CODE. ACCESSIBILITY CODE: 2010 ADAAG EXIT SEPARATION: .33 X 134' ** = 44'-3" REQUIRED 9, ALL NEW WALL INSULATION IF INSTALLED UNDER THIS CONTRACT TO HAVE A FLAME SPREAD RATING OF 1 00'-1 0' PROVIDED lip NOT MORE THAN 25 AND A SMOKE DEVELOPMENT RATING OF NOT MORE THAN 450. NEW ROOF INSULATION IF INSTALLED UNDER THIS CONTRACT TO HAVE A FLAME SPREAD RATING OF NOT MORE THAN 75 AND A ** MAXIMUM OVERALL DIAGONAL DISTANCE SMOKE DEVELOPMENT RATING OF NOT MORE THAN 450. NEW ROOF COVERING IF INSTALLED UNDER THIS CONTRACT WILL BE CLASS "A". MAXIMUM TRAVEL DISTANCE: 250' / 100' SHOWN 10. SUBMITTALS FOR SPRINKLER SYSTEM MODIFICATION AND ALARM WORK, WILL BE PROVIDED BY THE GC'S AISLES: SUB CONTRACTOR AND SUBMITTED TO THE CITY FOR REVIEW AND APPROVAL PRIOR TO CONSTRUCTION START. GC WILL ALSO HIRE INSTALLERS FOR SPRINKLER AND ALARM WORK. MINIMUM WIDTH: 36 IN. REQUIRED / 39 IN. PROVIDED 11. SUMITTALS FOR SIGNAGE PERMITS WILL BY FURNISHED BY THE INSTALLING CONTRACTOR, SIGNAGE (AREAS SERVING EMPLOYEES ONLY) DRAWINGS CONTAINED IN THIS SET ARE FOR GENERAL INFORMATION ONLY, MINIMUM WIDTH: 44 IN. REQUIRED / 48 IN.(min) PROVIDED (PUBLIC AREAS) MAX. DEAD END LENGTH = 20 FT. / 15 FT. SHOWN GENERAL NOTES DESIGNERS OF RECORD: 1. ALL SIGNAGE SHOWN WITHIN THESE DOCUMENTS (EITHER BUILDING OR FREESTANDING) SHALL BE ARCHITECTURAL SUPPLIED BY AUTOZONE, INC. AND INSTALLED BY THE SIGN VENDOR AT LOCATIONS INDICATED ON THE Name: PHILLIP PECORD DRAWINGS. BUILDING WALL SURFACES SHALL BE MADE READY TO RECEIVE SIGNAGE BY THE GENERAL License No: AROO11O16 LANDLORD TENANT: CONTRACTOR. Phone No: (901) 495-8706 LANDLORD APPROVAL 2. THE FOLLOWING ITEMS IF REQUIRED BY THE DOCUMENTS WILL BE SUPPLIED BY AUTOZONE, INC. AND INSTALLED BY THE GENERAL CONTRACTOR: STRUCTURAL LANDLORD: NORTH KINGS HWY, LLC, (A) ALL LIGHT FIXTURES, LAMPS, BALLASTS, ELECTRICAL PANELS, BREAKERS AND GEAR. Name: NATHAN MORROW INDRIO CROSSINGS c/o COLDWELL BANKER (B) ELECTRIC WATER HEATER License No: 73148 411 N. US HWY 1 PH I LLI (C) NEW HVAC ROOF —TOP UNITS, ROOF CURBS OR ADAPTERS, FIRESTATS, SMOKE DETECTORS AND Phone No: (614) 221-6679 ACCEPTED BY: PIERCE, FL 349510 THERMOSTATS, REFER TO SHEET M-1. (SIGNATURE REQUIRED) PHONE 772-370-1399 PECOR (D) VENSTAR HVAC AND LIGHTING CONTROLS MECHANICAL Indrio.Crossings.Plaza@gmail.com (E) BEST CYLINDER LOCKS FOR GLASS AND ALUMINUM ENTRY DOORS AND FOR TELEPHONE CLOSET DOOR, Name: DANNY DOSS 410D0 3. ALL UTILITIES SHALL BE PLACED IN AUTOZONE'S NAME FROM THE START OF THE PROJECT, THE License No: 35765 NOTE: AUTOZONE ASSUMES LANDLORD ACCEPTANCE OF PLANS IN THE EVENT PROJECT TENANT: AUTOZONE, INC. 77FD9 GENERAL CONTRACTOR SHALL PAY DEPOSITS ON AUTOZONE'S BEHALF AND SHALL SUBMIT RECEIPTS FOR Phone No: (479) 631-1712 A SIGNED SET IS NOT RETURNED BY : ????? 123 SOUTH FRONT STREET 00017 REIMBURSEMENT. ELECTRICAL MEMPHIS, TN 38103 PHONE 901 5-8729 4. PHONEBOARD, PHONE EQUIPMENT AND ALARM EQUIPMENT INSTALLATION SHALL BE ACCOMPLISHED Name: DANNY DOSS DAVID BENTLEY NTLEY PRIOR TO COMPLETION OF THE PROJECT. FOR FURTHER INFORMATION PLEASE CALL ALARM SERVICES License No: 35765 DEPARTMENT 8090: (901) 495-6699 or (901) 495-7197. Phone No: (479) 631-1712 All designs, drawings, plans, and specifications as instruments of service are and shall remain the property of AutoZone, Inc. Use is limited specifically to said property. Possession of plans does not authorize use of some for construction of other projects, any reproduction is prohibited without the express written consent of AutoZone. Written dimensions on these drawings shall have precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions on the job site. This office must be notified of any variation from the dimensions and conditions shown by drawings. Neither AutoZone, Inc. nor the designers responsible for the drawings herein will assume liability for mishaps before, during or after the application of said drawings as a guideline for actual construction. ® COPYRIGHT 1997 Ln C-0 0 O-) w N r� L J Q d' Z M Q w J LL 0 U C'7 O >� W Z > w Lu = Z Ll ry C II LLJ N z I— i 0 O Q00LL INC U C) 0o 4_j� d- v> a1 O o0 � o0 a� o M OU a� o o U o U 4-4 O 7O O M N Digitally signed by PHILLIP A01 C PECORD:AO141OD 001 00000177FD98D6 60E OEOOO17BC7 Date: 2021.05.26 7 09:22:18 -05'00' 05/28/2021 57N-REMODEL