HomeMy WebLinkAboutFL3607-A2_05-28-21(1)MARK LOCATION SIZE TYPE FRAME DELIVERY 3'-O"x7'-1O"x HOLLOW HOLLOW 0 0 DOOR V-3/4" METAL METAL 0 EMERGENCY EXIT 3'-O"x7'-O"x ~ 0 V-3 4" CD O RESTROOM DOOR 3'-O"x6'-8"x S.C. HOLLOW 0 1'-3/4" WOOD METAL O ENTRANCE 3'-O"x � -O"x ALUMINUM ALUMINUM - DOOR W/ GLASS PHONE 2'-6"x6'-8"x S.C. HOLLOW O CLOSET V-3/4" WOOD METAL 1/8" = 1'-0" 1 DOOR SCHEDULE JAMB DET. HEAD DET REMARKS 8/A2 8/A2 PAIR OF DOORS REQUIRED. SIM. Sim. 2/A2 2/A2 SIM. 2/A2 2/A2 SIM. UNDER CUT DOOR 1". 1/2" STD. OR 5/8" FIRE 5" CODE GYP, BOARD, REFER 3 5/8" 25 GA. 8 2 TO FLOOR PLAN KEY METAL STUD NOTES. E FLOOR Mlc�' I MAY BE EITHER SINGLE OR PAIR OF DOORS SEE FLOOR PLAN & EXTERIOR SPOT u� I ELEVATIONS. PAIRED DOORS MUST HAVE THREE POINT LOCKING. GROUT P1 TOILET P5 NOT USED P2 LAVATORY P6 FLOOR DRAIN P3 MOP SINK P7 WATER HEATER P4 ELECTRIC DRINKING FOUNTAIN P8 BACKFLOW PREVENTOR NOTE: WATER HEATER FURNISHED BY AUTOZONE O TOILET PAPER HOLDER- INTERDESIGN (WHITE) O PAPER TOWEL HOLDER- INTERDESIGN (WHITE) O 36" GRAB BAR-BOBRICK-#B-5806 x 36 ® 42" GRAB BAR-BOBRICK-#B-5806 X 42 . O MIRROR-18"X36"H, FRAMED GLASS-BOBRICK #13-165 © MOP HOLDER-BOBRICK #13-223 X 24" LONG, PAIR OF DOORS REQUIRED, UNDER CUT DOORS 1". O 18" GRAB BAR-BOBRICK-#B-5806 x 18 3 ANCHORS INTERDESIGN AVAILABLE FROM: RESOURCE MAINTENANCE INC. TEL. H. M. FRAME PER JAMB 704-792-1255 ATTN: THOMAS N. BOOE 3" H•M.DRY�ALL P-FIXT-SCHED = 1'-0'$ 1/8$$ = 1'-0" RR-ELEV-KEYNO TES OTES 2 HOLLOW METAL- FRAME—DRYWALL3 PLUMBING FIXTURE SCHEDULE 4 RESTROOM ELEVATION KEYNOTES DOOR O PR. 3' X 8' 18 GA. HOLLOW METAL DOORS AND 16 GA. HOLL( METAL FRAME WITH MITERED & WELDED CORNERS GROUND SMOOTH. HINGE: 16 GA. (3) PR. 4-1/2 x 4-1/2" NRP HAGER BB 1279P PUSH BAR EXIT DEVICE: DETEX, ADVANTEX, SERIES 40, W/ ALARM, PROVIDED BY AUTOZONE, INSTALLED BY G.C. CLOSER: LCN P4041, PLATED US26D PARALLEL ARM ON ACTIVE LEAF, VIEWER:190 DEGREE, IVES #698, CENTERED IN DOOR 5' ABOVE FLOOR. RIGID JAMB WEATHERSTRIPPING: NATIONAL GUARD PRODUCTS #43-CB. DOOR TOP RAIN DRIP:ALUMINUM, FULL WIDTH OF FRAME, NATIONAL GUARD PRODUCTS # 17. AUTOMATIC DOOR BOTTOM:ALUM., NATIONAL GUARD PRODUCTS #220SA SURFACE BOLTS:AUTOZONE FURNISHED, CONTRACTOR INSTALLED, DON-JO 8" AT BOTTOM & ROCKWOOD 24" AT TOP. EXTERIOR DOOR PROTECTION:3" WIDE x FULL HEIGHT x $" STEEL BAR WELDED TO ACTIVE LEAF MINIMUM 1" OVERLAP TO INACTIVE LEAF, KICK DOWN HOLDER:IVES #FS555, US 26D, (ONE FOR EACH LEAF). 3'-0" 0 0 00 NOTE: NO OUTSIDE HARDWARE PERMITTED. EXTERIOR LOADING DOORS 2" DEEP 18 GA. TRACK ANCHOR TO DECK W/ (2) # 10 SCREWS @ 12" STAGGARD 20 GA. STUDS AND TRACK CONNECT W/ #8 LOW PROFILE SCREWS @ EA. STUD -1L PROVIDE CORNER TRIM - AROUND ALL EDGES OF THE OPENINGS IN WALL WHERE BAR JOIST PASSES THROUGH BACK TO BACK 6" 16 GA. JOIST STUDS W/ 38" 20 GA, TRACK TOP & BOTTOM. RUN CONTINUOUS FROM BATH WALL TO END OF CURTAIN WALL, 1/2" GYPSUM BOARD W/ CORNER BEAD ON OUTSIDE CORNERS ROOFING SYSTEM OVER METAL DECK RECESS FRAME 1" FROM OUTSIDE EXTERIOR WALL, WEATHER STRIP 16 GA. HOLLOW METAL FRAME GROUT SOLID. 3"x3" ALUMINUM CORNER GUARD W/ MITERED CORNERS AT JAMB AND HEAD SEALANT 3 EXPANSION BOLTS PER JAMB. a a a a II LJ a a EXISTING GYPSUM BOAR ON METAL STUDS NOTE: INTERIOR RESTROOM WALL SURFACES TO BE COVERED WITH GENERAL PURPOSE "FRP" BOARD, TEXTURED, COLOR WHITE. NOTE: INTERIOR CEILING HEIGHT = 8'-0". CEILING TO BE SUSPENDED Y2" GYPSUM BOARD PAINTED WHITE. INSTALL SOUND INSULATION ABOVE BATHROOM CEILING. NOTE: INSTALL 1/2" CD PLYWOOD TO 4' ABOVE FLOOR AROUND EXTERIOR OF RESTROOMS, PAINT RED. NOTE: INSTALL SEALANT BETWEEN MOP SINK AND ALL ADJOINING SURFACES, NOTE: LOCATION OF ELECTRIC PANELS IF NEW ARE REQUIRED. 3" X 3" ALUMINUM CORNER GUARD, 8'-0" HIGH. (TYPICAL ON ALL EXPOSED CORNERS) 00 Ln 1 1/2" DIAMETER PIPE GUARD RAIL 2'-0" ON EITHER SIDE OF DRINKING FOUNTAIN. PAINT RAIL RED AND 7'-4„ ANCHOR TO FLOOR AND WALL, OVERALL HEIGHT TO BE 32" AND BOTTOM HORIZONTAL TO BE NO MORE THAN 5" ABOVE FLOOR LINE, NOTE: REFER TO 1/Al FOR RESTROOM LOCATION NOTE: WALL CONSTRUCTION= 25 GA, 3-5/8" METAL STUDS AT 16" O.C., 1/2" GYPSUM BOARD BOTH SIDES WHERE REQUIRED, SOUND BATT INSULATION TO 8'-0" HIGH, FINISHED GYPSUM BOARD SURFACES TO 6" ABOVE MAIN CEILING. IF NO CEILING IN STORE RUN PERRIMETER WALLS AND FINISH TO UNDERSIDE OF EXPOSED STRUCTURE. 1 1/2" = 1'-0" H.M.BLOCK 3/16 = 1'-0" g HOLLOW METAL FRAME -BLOCK X RESTROOM PLAN BAR JOIST„ a I 38" 20 GA. STEEL STUDS @ 16" O.C. m 7'-2" TO FINISHED FLOOR CLEAR DIMENSION Qo I Qo N I NO 6 CD P3 � E ll�l 11` [/ MEN WOMEN 36" 3 v 4n„ 010 Sb MEN �b 10"X10" MILCOR WMEN # �/ DOOR AT CUT OFF ATTACH EXPOSED BACKFLOW PREVENTOR BACKFLOW PREVENTER TO WALL IN A SECURE P SALES FLOOR SIDE MANNER TO PREVENT ANY MOVEMENT BY ASSEMBLY AND TO ALLOW FOR REPLACEMENT OF PARTS C' IF REQUIRED I P3`I' LBATH-2 LINE OF RESTROOM CEILING BE OND CONTINUOUS " WALL TO HANDICAP 6 ABOVE \ACCESSIBLE CEILING \ 0 ADA L,7 0 Z L e i APPROVED - ROOM SIGN CLEANOUT WHITE 1 1/2" DIA. PIPE LETTERS, GRAY 3" X 3" ALUMINUM CORNER GUARD RAILS BACKGROUND GUARD, 8'-0" HIGH 3/ 16" = 1 ' -0'$ LBATH3 12 RESTROOM EXTERIOR ELEVATION 1. FOR NEW RESTROOM CONSTRUCTION, FRAME WALLS AND CEILINGS WITH 3 5/8" METAL STUDS 16" ON CENTER, PROVIDE ALL WOOD BLOCKING AS NECESSARY TO ADEQUATELY SUPPORT ALL RESTROOM ACCESSORIES, SEE PLANS AND ELEVATIONS THIS SHEET FOR DETAILS, 2, APPLY 1/2" GYPSUM BOARD TO ALL WALLS AND CEILING. TAPE, BED AND SAND SMOOTH. 3, APPLY WHITE FRP BOARD, .090 THICKNESS, TO ALL INTERIOR WALLS AND WALLS AROUND MOP SINK FULL HEIGHT. 4. PROVIDE 3" X 3" ALUMINUM CORNER GUARD, 8'-0" HIGH AT ALL EXPOSED CORNERS. PHILL F PECO 5. REFER TO SHEET P-1 FOR ALL PLUMBING DETAILS D000 AND NOTES. D60E ( 6. FOR EXISTING RESTROOMS, REFER TO SHEET A-1 FOR THE OVERALL SCOPE OF WORK AND THIS SHEET FOR NOTE. INSTALL 6 WIDE, 20GA. METAL STRIP HORIZONTALLY BOTH SIDES OF WALL BEHIND GYP.BD. ATTACH TO HORIZONTAL TRACK AT 16" O.C. AND EACH STUD, I I 5MEN WOMEN 6 SPECIFIC DETAILS. CENTER OF STRIP TO BE 90" A.F.F. NOTE: RESTROOMS AS DESIGNED ARE IN COMPLIANCE WITH CURRENT AMERICAN DISABILITIES ACT STANDARDS AND GUIDELINES. NOTIFY THE PROJECT MANAGER ON ANY LOCAL ADMENDMENTS FOR ADDITIONAL COMPLIANCE. 3 / 8 " — ' — 0 " A I S 0 4 7 N 2 NOTE: CAULK AROUND ALL FIXTURES WITH WHITE SEALANT 10 CURTAN 3/16" = 1'-0" RR-INT-LELEV 1/8" = 1'-0" RR -NOTES F117RESTROOV INTERIOR ELEVATIONS RESTROOM NOTES V J W O z \ z O d--- Ln LO Q W J W \ z Q J (r-) CD G O O w N � VJ mow/ L.L r V ) L J Q ,;I- w J LL \ W � M '� > Q z W = L_ o� cf) Lu 00 U) Z W Cn O Z N �O o N (3)1 O O Q co LL 0 110 o 4 �n O o0 v� � i~ OU M W'No 00 U .O bA 4-5 o � w Digitally signed by C PHILLIP C :A01410 PECORD:AO1410D 177FD98 0000177FD98D60E 00017BC7 17BC7 Date:2021.05.26 09:23:40-05'00' 05/28/2021 57N-REMODEL A�2